AKpe^Hxai^HOHO xejio Cp5HJe 01420 Beorpaff...
Transcript of AKpe^Hxai^HOHO xejio Cp5HJe 01420 Beorpaff...
^ -..^^w->^ AKpe Hxai HOHO xejio Cp5HJe 01420 " ly_ Accreditation Body of Serbia
i . ^ , . Beorpaff Belgrade
^oflcjbyje awards
C E P T H O H K A T O A K P E A H T A U H J H Accreditation Certificate
KOJHM ce noxBp^yje j a xejio 3a oi eH>HBaii>e ycarjiamenocxH confirming that Conformity Assessnnent Body
P y a a p c K H HHCTHxyx 3 .0 .0 . B e o r p a f l
J l a S o p a x o p H J a 3 a r e o M e x a n H K y
B e o r p a a - 3 e M y H
aKpe Hxai HOHH 6poj accreditation number
01-309 saflOBOJtaBa saxxcBC cxaH^ap^a
fulfils the requirements of
SRPS ISO/IEC 17025:2006 (ISO^ECl 7025:2005)
x e je K O M n e x c H X H O s a o o a B i b a i t e n o c j i O B a H c n n x H B a i t a and is competent to perform testing activities
KOJH c y cnei^H(})Hi^HpaHH y e a x e h e M H s ^ a i t y 0 6 H M a a K p e ^ H x a i ^ H J e as specified in the valid Scope of Accreditation
Baxehe HSAaite 06HMa aKpeAHTai],HJe AocxynHO je Ha HHxepHex aj^pecn: www.ats.rs Valid Scope of Accreditation can be found at: www.ats.rs
A K p e A H x a i ^ H J a A O A e j L C H a Date of issue
21.01.2018. A K p e A H T a u , H J a Ba^aa 3 0
Date of expiry
20.01.2022. ATC
\ > - — ^ B. fl. J] ,HpeKTOp
Director
AKpeAHxau;HOHo xej io CpSaje je noxnncHHK Myj ixHj iaxepajb npHSHasai ty eKBHsajieHXHOcxH CHCxeMa aKpenHxai],HJe E B p o n c K e opraHH3ai];HJe 3a
aKpeAHxai^HJy (EA MLA) H ILAC MRA cnopa3yMa y OBOJ oSj iacxH. / ATS is a signatory of the EA MLA and ILAC MRA in this field.
AKPE/^HTAqHOHO AKpe;iHTaqHOHH Qpo]lAccreditation No: OsHaKa npsmeTa/FHe Ref.
T T T T T n ^ ^ " ^ ^ ^ 2-01-361 Ba>KHOfl/
P P K T / T T P Valid from: K^royun 12.09.2018. ATC Z axyM npse aKpeflHTaLlHJe/ SaMeitvie 05HM oa:
Date of initial accreditation: 20.01.2010. '^'P'''^''^'Z'/T,o
OBHM AKPEAHTAI^HJE Scope of Accreditation
AKpcAHTOBaHO xejio 3a oueibHsaibe ycarjiameHocxH/ Accredited conformity assessment body
Py/iapcKH HHCXHxyx fl.o.o. Eeorpa^
JIa6opaxopHJa 3a reoMexanHKy
BeorpaA-3eMyH, EaxaJHHHKH nyx 2
CraHAapA / Standard:
SRPS ISO/IEC 17025:2006
(ISO/IEC 17025:2005)
CKpahcHH O 6 H M aKpeAHxauHJe / Short description of the scope
- 3)H3HHKa H MexaHHHKa H C H H T H B a i t a rpa^eBHHCKHx MaxepHJana ( reoMexaHHHKO HcnHXHBaH>e
xjia) / Physical and mechanical testing of building materials (geomechanical testing of soils)
- MexaHHHKa HCHHXHBaH>a rpa^eBHHCKHx Maxepnjajia (cxene) / Mechanical testing of building materials (rocks).
AKpeflHxauHOHH 6poj/ Accreditation No
Ba^uoa/Valid from: 12.09.201! 3aMeH.yje 06HM ofl / e/?/ace5 5cope coatee/; 21.01.201!
ATC
JlersijhaH O 6 H M aKpeaHxauHJe/De^a/Zerf description of the scope
MecTo HcnHTHBaH>a: y jia6opaTopHJH <I)H3HHKa H MexaHHHKa HCHHTHBaH>a rpa eBHHCKHx MarepHJajia (reoMexannHKo HCHHTHBaH>e TJia)
P. B.
npeflMCT HcnHTHBaH>a/ MarepHJaji /
npoH3Bo ; i
Bpcra H C B H T H B a i b a H / H J I H
KapaicrepHCTHKa Koja ce MepH ( r e x H H K a HcnHTHBaiba)
Oncer Mepeiba (rut j e
npHivieibHBo)
Pe epeHTHH flOKyivieHT
1 . Tjio Oflpe HBatfce Bjia>KHocTH ysopaKa xjia
SRPSU.B1.012:1979 - noeyneH
Oflpel)HBaH.e 3anpeMHHCKe Mace MarepHJajia xjia ca nopaisia MexoflOM ca U H U H H ^ P O M
nosHaxe sanpcMHHe
SRPS U.B1.013:1992 - noeyneH
Oflpe HBaifce sanpeMHHCKe Mace MaxepHJana xjia ca nopaMa MexoflOM noxanaH>a ysopaKa y BOfly
SRPS U.B1.017:1992 - noeyueH
-Oflpe^HBaifce rpaHyjiOMCxpHJCKor cacxaBa
XH;3poMeTpHcaH.e -npcHHHK necTHua
jxo 0,063 mm cejaite - npeHHHK HecTHua (0,063-
75) mm
SRPS U.B1.018:2005 - noeyneH
0/ipel)HBaH,e KOHSHCxeHUHJe xjia SRPS U.B1.020:1980 - noeyneH
OflpeI)HBaH>e napaMexapa Hspcxohe onHxoM AHpeKXHor CMHuafta xna
o ;io 400 kN/m- x m 5-
300 mim^
SRPS U.B1.028:1996 - noeyneH
Oflpe^HBafte npHXHcne HBpcxohe xjia CHJia 0-50 kN SRPS U.Bl.030:111-
1968 - noeyHCH
Oapel)HBaH>e cxHuutHBOCxH xjia Qjxo 1600 kN/m- SRPS U.B1.032:VII-1969 - noeyneH
Oflpel)HBaH.e OAHOca BJia>KH0cxH H cyBe 3anpeMHHCKe Mace xjia
SRPS U.B1.038:1997 - noeyneH
Jla6opaxopHJcKo oflpe^HBafte KajiH(})opHHJCKor HnaeKca HOCHBOCXH
CHjia 0-50 kN SRPS U.Bl.042:1997 - noeyneH
FeoxexHHHKo Hcxpa>KHBaH>e H HcnHXHBaH>e - JlaSopaxopMJcKO HcnHXHBafte xjra ^eo 1: OflpeI)HBaH.e BJia>KH0cxH
SRPS EN ISO 17892-1:2015, x.5.1
A T C - n ? 15-002 H3.aaH>e/H3MeHa: 3/6 JXaryu: 09.02.2016. CxpaHaTl /4A ( lO Ti .fry,
A K p e z i H T a u H O H H 5poj/ Accreditation No "^--^"^ i t '
, Ba>KH oa/J a/?W/row: 12.09.2018. 3aMe}by}e 06nM OR / Replaces Scope dated: 21.01.2018.
ATC
MecTO HcnHTHBaiba: y jia5opaTopHJH ^H3HHKa H MexaHHHKa HcnHTHBaH>a rpa CBHHCKHx MarepHJajia (reoMexannHKO HcnnrHBaibe rjia)
P. B.
I Ipe f lMer HCHHrHBaiba/
MarepHJaji / npOH3BOiI
B p c r a HcnHTHBaH>a H / H J I H
K a p a K r e p H c r H K a K o j a ce MepH
( r e x H H K a HcnHTHBaH>a)
Oncer MepeH>a
(rae je n p H M e i b H B o )
Pe4)epeHrHH
flOKyMCHr
1. TJIO FeOTeXHHHKO HCTpa>KHBaH>e H
HcnHTHBaH>e - J l a G o p a x o p H J C K O
HCHHTHBaH-e TJia ^ e o 2: OApe^HBaH>e s a n p e M H H C K e Mace
SRPS E N ISO 17892-2:2015
FeOTeXHHHKO HCTpa>KHBaH.e H HcnHTHBaH>e - J l a S o p a x o p H J c K o
HCHHXHBaHje x j i a J\eo 3: OApe^HBaH>e Mace je f lHHHHHe
s a n p e M H H e HecxHU,a -
riHKHOMexapcKa M c x o a a
SRPS E N ISO 17892-3:2016
-F e o x e x H H H K O Hcxpa>KHBaH>e H
HcnHXHBaH>e - J l a G o p a x o p H J c K o
HcnHXHBaH>e x j i a ^ e o 4: O ipe^HBaHDe r p a n y j i O M e x p H J C K o r c a c x a s a
XHflpoMexpHcaifce - npeHHHK
necxHua ao 0,063 mm
CejaH>e - npeHHHK necxHua 0,063 mm
- 75 mm
SRPS E N ISO 17892-4:2017, HsyscB x.5.4
F e o x e x H H H K o Hcxpa>KHBaH>e H
HcnHXHBaH>e - Jla5opaxopHJcKo HcnHXHBaH,e xna fleo 5: E f l O M a x e p c K o HcnHXHBaH.e
cxeneHacxHM onxepeheH>eM
cao 1600kN/m2 SRPS E N ISO 17892-5: 2017
F e o x e x H H H K o HCxpa>KHBaHje H
HCHHXHBafte - Jla6opaxopHJCKO HCHHXHBafte x j i a J^eo 7: Oape^HBaH^e j e a H o a K C H J a j i H e
H B p c x o h e npH npHXHCKy n a
CHXHOspna r j i a
CHJia 0-50 kN SRPS E N ISO 17892-7: 2018
F e o x e x H H H K O Hcxpa>KHBaH.e H
HcnHXHBaH>e - J I a 5 o p a x o p H J C K O
HcnHXHBaH>e x j i a ^ e o 10: H c n H X H B a H . e ^ H p e K X H o r
CMHu,aH>a
a RO 400 kN/m^ T OR 5-300 kN/m^ SRPS E N ISO/TS
17892-10: 2011
F e o x e x H H H K O HCxpaacHBafte H
HcnHXHBaH.e - Jla6opaxopHJCKo HcnHXHBaH.e x j i a ^ e o 12: OjipeffHBaibQ A x e p 6 e p r o B H x
rpaHHua
SRPS C E N ISO/TS 17892-12:2011
AKpeaHTauHOHH 6poj/ Accreditation No "^"-'"^
Ba>KH ofl/Ka/W/roffz: 12.09.201i 3aMeiby}e O611M oji./Replaces Scope dated: 21.01.201!
ATC
MecTO HcnHTHBaiba: y jia6opaTopHJH <I>H3HHKa H iviexaHHHKa HCHHTHBaiba rpa^CBHHCKHx MarepHJajia (reoMCxaHHHKO H c n H T H B a i t e x j i a )
P. B.
npeaMCT HcnHTHBaiba/
MarepHJaji / npoH3Bo;]
B p c r a HcnHTHBaH>a H / H J I H
KapaKTcpHCTHKa Koja ce MepH
(rexHHKa HcnHTHBaiba)
O n c e r Mepeiba
( rae je npHMeibiiBo)
Pe4>epeHTHH
flOKyMenr
1. T J I O HeBesane H xH paynHMKHM BCSHBOM Besane MemaBHHe -J\eo 2: Mexofle HcnHXHBaiba sa jiaSopaxopHJCKy pecJjepcHXHy Macy H caflp>Kaj Boae - 36HJaH>e no ripoKxopy
SRPS EN 13286-2:2012/ AC 2013 H3y3eB x.7.3 H 7.6
HeBesane H xnapayjiKHKHM BCSHBOM Besane MemasHHe -Jleo 47: Mexo^e HcnHXHBaH.a 3a 0flpel)HBaH.e Kajin^opHHJcKor HHfleKCa HOCHBOCXH, Henocpe Hor HHACKca HOCHBOCXH H JIHHCapHOr 6y6peH.a
CHJia 0-50 SRPS EN 13286-47:2012
Mecro HcnnrHBaiba: y naGopaxopnJH MexaHHHKa HcnnrHBaiba rpa^eBHHCKHx MarepHJajia (crene)
P. B.
npcAMer HCHHTHBaiba/
Marepnjaji / npOH3BO/I
B p c r a HCHHTHBaiba H / H J I H
KapaicrepHCTHKa Koja ce Mepn
(rexHHKa ncnnrHBaiba)
O n c e r Mepeiba (rae je
npHMeibHBo)
Pe«j)epeHTHH
aOKyMCHT
1. Crene Oflpel}HBaH>e jeflHOOcne npHXHCHe HBpcxohe
CHJia 0-1 MN
SRPS B.B7.126:1988 - noeyneH
OApe^HBaHje saxesne HBpcxohe
HHflHpeKXHOM MeXOflOM Cwjia
0-0,2 MN SRPS B.B7.127:1988 - noeyneH
Osaj 0 6 H M aKpcAHxaiiHJe B a ^ H caMo ys CepxH(J)HKax o aKpejiHxaanJH 6poj 01-309 This Scope of accreditation is valid only with Accreditation Certificate No 01-309
AKpe^HxauHJa Ba^H jxo: 20.01.2022. Accreditation expiry date: 20.01.2022.
A T C - n ? 15-002 Msaatbe/HsMeHa: 3/6 /laxyM CTpaHa:4/4