AKE Technical Document; Report and Specification - Tema … req guidelines - Isoltykkelser… ·...
Transcript of AKE Technical Document; Report and Specification - Tema … req guidelines - Isoltykkelser… ·...
Aker Kværner Engineering & TechnologyReport
Document No.:37-1A-AK-R15-00003
Rev.:04I
Page: 1 of 15
Classification Code:Originator: AK Tag No.: System No. :00 Area Code:
CTR No.:
Document Title: INSULATION REQUIREMENTS, GUIDELINE
04I 15.03.04 ISSUED FOR CONSTRUCTION EAF EH KAB
03F 20.01.04 ISSUED FOR DETAIL ENGINEERING EAF EH KAB
02 07.01.04 REISSUED FOR IDC EAF EH KAB
01 10.09.03 ISSUED FOR IDC EAF EH KABRev. Issue
DateDescription Made
byChk'd
byDisc.Appr.
Proj.Appr.
Project No.: 5715 Contract No.: 37-00-NH-B45-5186498
Ormen Lange Project EPCMA Contract for the Onshore Terminal
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 2 of 15
1. PURPOSE.........................................................................................................................4
2. REFERENCES................................................................................................................4
3. GENERAL.......................................................................................................................4
4. INSULATION CLASSES, GUIDANCE FOR INSULATION THICKNESS...........54.1. Class 1: Heat conservation.........................................................................................54.2. Class 2: Cold conservation & external condensation and icing protection...........54.3. Class 3: Personnel protection.....................................................................................54.4. Class 4: Frost proofing...............................................................................................54.5. Class 5: Fire proofing.................................................................................................64.6. Class 6: Acoustic insulation Type A, B and C..........................................................64.6.1. Type A.......................................................................................................................64.6.2. Type B.......................................................................................................................64.6.3. Type C......................................................................................................................64.7. Class 7: Heat tracing...................................................................................................64.8. Class 8: Fire protection of flanges only.....................................................................74.9. Class 9: Future insulation..........................................................................................7
5. COMBINATION OF INSULATION CLASSES - GUIDANCE FOR INSULATION THICKNESS....................................................................................................................8
5.1. Class 13 (Heat conservation + Personnel protection)..............................................85.2. Class 15 (Heat conservation + Fire proofing)...........................................................85.3. Class 16 (Heat conservation + Acoustic insulation).................................................85.3.1. Heat conservation + Acoustic insulation type A......................................................85.3.2. Heat conservation + Acoustic insulation type B......................................................95.3.3. Heat conservation + Acoustic insulation type C......................................................95.4. Class 18 (Heat conservation + Fire protection of flanges only)..............................95.5. Class 25 (Cold conservation & external condensation and icing protection + Fire
proofing).......................................................................................................................95.6. Class 26 (Cold conservation & external condensation and icing protection +
Acoustic insulation)...................................................................................................105.6.1. Cold conservation & external condensation and icing protection + Acoustic
insulation type A.....................................................................................................105.6.2. Cold conservation & external condensation and icing protection + Acoustic
insulation type B.....................................................................................................105.6.3. Cold conservation & external condensation and icing protection + Acoustic
insulation type C....................................................................................................105.7. Class 28 (Cold conservation & external condensation and icing protection + Fire
protection of flanges only)........................................................................................105.8. Class 35 (Personnel protection + Fire proofing)....................................................115.9. Class 36 (Personnel protection + Acoustic insulation)..........................................115.9.1. Personnel protection + Acoustic insulation type A................................................11
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 3 of 15
5.9.2. Personnel protection + Acoustic Insulation type B...............................................115.9.3. Personnel protection + Acoustic Insulation Type C..............................................115.10. Class 38 (Personnel protection + Fire protection of flanges only)........................125.11. Class 45 (Frost proofing + Fire proofing)...............................................................125.12. Class 46 (Frost proofing + Acoustic insulation).....................................................125.12.1. Frost proofing + Acoustic insulation type A.........................................................125.12.2. Frost proofing + Acoustic insulation type B..........................................................125.12.3. Frost proofing + Acoustic insulation type C..........................................................135.13. Class 47 (Frost proofing + Heat tracing)................................................................135.14. Class 48 (Frost proofing + Fire protection of flanges only)..................................135.15. Class 56 (Fire proofing + Acoustic insulation).......................................................135.15.1. Fire proofing + Acoustic insulation type A............................................................135.15.2. Fire proofing + Acoustic insulation type B............................................................135.15.3. Fire proofing + Acoustic insulation type C...........................................................145.16. Class 57 (Fire proofing + Heat tracing)..................................................................145.17. Class 67 (Acoustic insulation + Heat tracing)........................................................145.17.1. Acoustic insulation type A + Heat tracing.............................................................145.17.2. Acoustic insulation type B + Heat tracing.............................................................145.17.3. Acoustic insulation type C + Heat tracing.............................................................145.18. Class 68 (Acoustic insulation + Fire protection of flanges only)...........................155.18.1. Acoustic insulation type A + Fire protection of flanges only................................155.18.2. Acoustic insulation type B + Fire protection of flanges only................................155.18.3. Acoustic insulation type C + Fire protection of flanges only................................15
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 4 of 15
1. PURPOSE
The purpose of this report is to give the estimated minimum insulation thicknesses for piping, vessel and equipment insulation for the Ormen Lange Onshore Plant. The thicknesses given are to be used for design purposes, such as 3D modelling, so that adequate space for insulation can be allocated for piping, vessels and equipment.
The applicable documents giving the insulation requirements for the Ormen Lange Onshore Plant are stated in chapter 2 of this document.
2. REFERENCES
NORSOK R-004, rev. 2 Insulation of Piping and EquipmentNHT-M50-02037, rev. 03M Piping and Equipment Insulation, Supplement to NORSOK R-004,
rev. 2.Insulation Handbook
3. GENERAL
The basis for the estimated thicknesses is NORSOK R-004, NHT-M50-02037 and experience from previous projects.
Requirements to insulation material build up are stated in NORSOK R-004 and NHT-M50-02037.
The extent of insulation is defined by the process discipline with input from other disciplines, especially safety discipline, and shown on P & IDs.
Possible use of epoxy type Passive Fire Protection material shall be considered for the slug catchers if fire protection is required.
In-line instruments shall be considered part of pipeline and shall follow the same insulation requirements as the pipe.
Personnel protection distance pins shall be designed and installed so that possible damage to the applied coating is prevented.
Equipment installed in pipelines where insulation is required and that requires regular maintenance, replacement, inspection etc., such as probes for corrosion monitoring, are to be insulated with removable insulation.
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 5 of 15
4. INSULATION CLASSES, GUIDANCE FOR INSULATION THICKNESS
It should be emphasised that the thicknesses given are estimated thicknesses and are to be used for design purposes only.
4.1. CLASS 1: HEAT CONSERVATION
Thickness CommentsPiping / Vessels Ref. table 1, NORSOK R-004
+ 5 mmFor oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm For oper. temp. > 420 oC
Flanges / Valves NA (Same thickness as for piping / vessels, min. 100 mm)
Insulated where specified
4.2. CLASS 2: COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION
Same as a combination of insulation classes 2 and 9 according to Norsok R-004, rev. 2.Thickness Comments
Piping / Vessels Ref. table 3, NORSOK R-004 + 5 mm
Flanges / Valves Same thickness as for piping / vessels, min. 100 mm
Flange / Valve boxes shall be completely filled with insulation material. No void is allowed.
4.3. CLASS 3: PERSONNEL PROTECTION
Distance from element CommentsPiping / Vessels Ref. table 1, NORSOK R-004 Perforated sheet metal guardsFlanges / Valves
4.4. CLASS 4: FROST PROOFING
Same as insulation class 4 without heat tracing according to Norsok R-004, rev. 2.Thickness Comments
Piping / Vessels<= DN80 35 mm> DN80 45 mm
Flanges / Valves 100 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 6 of 15
4.5. CLASS 5: FIRE PROOFING
Thickness CommentsPiping / Vessels
<= DN150 85 mm> DN150 95 mm
Flanges / Valves 100 mm
4.6. CLASS 6: ACOUSTIC INSULATION TYPE A, B AND C
Insulation type A, B or C is to be shown as a note on P & ID's.
4.6.1. TYPE ASame as insulation class 6 according to Norsok R-004, rev. 2.
Thickness CommentsPiping / Vessels
<= DN150 60 mm> DN150 70 mm
Flanges / Valves NA (100 mm) Insulated where specified
4.6.2. TYPE BSame as insulation class 7 according to Norsok R-004, rev. 2.
Thickness CommentsPiping / Vessels
<= DN150 75 mm> DN150 85 mm
Flanges / Valves NA (100 mm) Insulated where specified
4.6.3. TYPE CSame as insulation class 8 according to Norsok R-004, rev. 2.
Thickness CommentsPiping / Vessels
<= DN150 110 mm> DN150 120 mm
Flanges / Valves 150 mm
4.7. CLASS 7: HEAT TRACING
Always in combination with other insulation classes.
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 7 of 15
4.8. CLASS 8: FIRE PROTECTION OF FLANGES ONLY
Thickness CommentsFlanges 100 mm
4.9. CLASS 9: FUTURE INSULATION
Thickness CommentsPiping / Vessels 100 mmFlanges / Valves
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 8 of 15
5. COMBINATION OF INSULATION CLASSES - GUIDANCE FOR INSULATION THICKNESS
The insulation build up for the class with the strongest requirements shall prevail. However, the total insulation build up shall maintain the insulation requirement for each separate insulation class in the combination.
5.1. CLASS 13 (HEAT CONSERVATION + PERSONNEL PROTECTION)
Thickness CommentsPiping / Vessels Ref. table 1, NORSOK R-004
+ 5 mmFor oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm
For oper. temp. > 420 oC
Flanges / Valves Ref. table 1, NORSOK R-004 Perforated sheet metal guards installed in distance to element to be protected, if not otherwise specified
5.2. CLASS 15 (HEAT CONSERVATION + FIRE PROOFING)
Thickness CommentsPiping / Vessels Ref. table 1, NORSOK R-004
+ 55 mmFor oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm
For oper. temp. > 420 oC
Flanges / Valves Same thickness as for piping / vessels, min. 100 mm
5.3. CLASS 16 (HEAT CONSERVATION + ACOUSTIC INSULATION)
5.3.1. HEAT CONSERVATION + ACOUSTIC INSULATION TYPE AThickness Comments
Piping / Vessels Ref. table 1, NORSOK R-004 + 30 mm
For oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm
For oper. temp. > 420 oC
Flanges / Valves NA (Same thickness as for piping / vessels, min. 100 mm)
Insulated where specified
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 9 of 15
5.3.2. HEAT CONSERVATION + ACOUSTIC INSULATION TYPE BThickness Comments
Piping / Vessels Ref. table 1, NORSOK R-004 + 45 mm
For oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm
For oper. temp. > 420 oC
Flanges / Valves NA (Same thickness as for piping / vessels, min. 100 mm)
Insulated where specified
5.3.3. HEAT CONSERVATION + ACOUSTIC INSULATION TYPE CThickness Comments
Piping / Vessels Ref. table 1, NORSOK R-004 + 80 mm
For oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 40 mm
For oper. temp. > 420 oC
Flanges / Valves Same thickness as for piping / vessels, min. 150 mm
5.4. CLASS 18 (HEAT CONSERVATION + FIRE PROTECTION OF FLANGES ONLY)
Thickness CommentsPiping / Vessels Ref. table 1, NORSOK R-004
+ 5 mmFor oper. temp. < 420 oC.
Ref. table 2, NORSOK R-004 + 5 mm
For oper. temp. > 420 oC
Flanges Same thickness as for piping / vessels, min. 100 mm
Valves NA (Same thickness as for piping / vessels, min. 100 mm)
Insulated where specified
5.5. CLASS 25 (COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + FIRE PROOFING)
Thickness CommentsPiping / Vessels Ref. table 3, NORSOK R-004
+ 55 mmFlanges / Valves Same thickness as for piping /
vessels, min. 100 mmFlange / Valve boxes shall be completely filled with insulation material. No void is allowed.
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 10 of 15
5.6. CLASS 26 (COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + ACOUSTIC INSULATION)
5.6.1. COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + ACOUSTIC INSULATION TYPE A
Thickness CommentsPiping / Vessels Ref. table 3, NORSOK R-004
+ 30 mmFlanges / Valves NA (Same thickness as for
piping / vessels, min. 100 mm)Insulated where specified
5.6.2. COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + ACOUSTIC INSULATION TYPE B
Thickness CommentsPiping / Vessels Ref. table 3, NORSOK R-004
+ 45 mmFlanges / Valves NA (Same thickness as for
piping / vessels, min. 100 mm)Insulated where specified
5.6.3. COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + ACOUSTIC INSULATION TYPE C
Thickness CommentsPiping / Vessels Ref. table 3, NORSOK R-004
+ 80 mmFlanges / Valves Same thickness as for piping /
vessels, min. 150 mm
5.7. CLASS 28 (COLD CONSERVATION & EXTERNAL CONDENSATION AND ICING PROTECTION + FIRE PROTECTION OF FLANGES ONLY)
Thickness CommentsPiping / Vessels Ref. table 3, NORSOK R-004
+ 5 mmFlanges / Valves Same thickness as for piping /
vessels, min. 100 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 11 of 15
5.8. CLASS 35 (PERSONNEL PROTECTION + FIRE PROOFING)
Thickness CommentsPiping / Vessels
<= DN150 85 mm> DN150 95 mm
Flanges / Valves 100 mm
5.9. CLASS 36 (PERSONNEL PROTECTION + ACOUSTIC INSULATION)
5.9.1. PERSONNEL PROTECTION + ACOUSTIC INSULATION TYPE AThickness Comments
Piping / Vessels<= DN150 60 mm> DN150 70 mm
Flanges / Valves Ref. table 1, NORSOK R-004 Perforated sheet metal guards to be installed in distance to element to be protected, if not otherwise specified
5.9.2. PERSONNEL PROTECTION + ACOUSTIC INSULATION TYPE BThickness Comments
Piping / Vessels<= DN150 110 mm> DN150 120 mm
Flanges / Valves Ref. table 1, NORSOK R-004 Perforated sheet metal guards to be installed in distance to element to be protected, if not otherwise specified
5.9.3. PERSONNEL PROTECTION + ACOUSTIC INSULATION TYPE CThickness Comments
Piping / Vessels<= DN150 110 mm> DN150 120 mm
Flanges / Valves 150 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 12 of 15
5.10. CLASS 38 (PERSONNEL PROTECTION + FIRE PROTECTION OF FLANGES ONLY)
Thickness CommentsPiping / Vessels Ref. table 1, NORSOK R-004 Perforated sheet metal guards to be
installed in distance to element to be protected, if not otherwise specified
Flanges 100 mmValves Ref. table 1, NORSOK R-004 Perforated sheet metal guards to be
installed in distance to element to be protected, if not otherwise specified
5.11. CLASS 45 (FROST PROOFING + FIRE PROOFING)
Thickness CommentsPiping / Vessels
<= DN80 85 mm> DN80 95 mm
Flanges / Valves 100 mm
5.12. CLASS 46 (FROST PROOFING + ACOUSTIC INSULATION)
5.12.1. FROST PROOFING + ACOUSTIC INSULATION TYPE AThickness Comments
Piping / Vessels<= DN80 60 mm> DN80 70 mm
Flanges / Valves 100 mm
5.12.2. FROST PROOFING + ACOUSTIC INSULATION TYPE BThickness Comments
Piping / Vessels<= DN80 75 mm> DN80 85 mm
Flanges / Valves 100 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 13 of 15
5.12.3. FROST PROOFING + ACOUSTIC INSULATION TYPE CThickness Comments
Piping / Vessels<= DN80 110 mm> DN80 120 mm
Flanges / Valves 150 mm
5.13. CLASS 47 (FROST PROOFING + HEAT TRACING)
Same as insulation class 4 with heat tracing according to NORSOK R-004, rev. 2.Thickness Comments
Piping / Vessels<= DN200 45 mm> DN200 55 mm
Flanges / Valves 100 mm
5.14. CLASS 48 (FROST PROOFING + FIRE PROTECTION OF FLANGES ONLY)
Thickness CommentsPiping / Vessels
<= DN80 35 mm> DN80 45 mm
Flanges / Valves 100 mm
5.15. CLASS 56 (FIRE PROOFING + ACOUSTIC INSULATION)
5.15.1. FIRE PROOFING + ACOUSTIC INSULATION TYPE AThickness Comments
Piping / Vessels<= DN150 85 mm> DN150 95 mm
Flanges / Valves 100 mm
5.15.2. FIRE PROOFING + ACOUSTIC INSULATION TYPE BThickness Comments
Piping / Vessels<= DN150 90 mm> DN150 100 mm
Flanges / Valves 100 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 14 of 15
5.15.3. FIRE PROOFING + ACOUSTIC INSULATION TYPE CThickness Comments
Piping / Vessels<= DN150 110 mm> DN150 120 mm
Flanges / Valves 150 mm
5.16. CLASS 57 (FIRE PROOFING + HEAT TRACING)
Thickness CommentsPiping / Vessels
<= DN200 95 mm> DN200 105 mm
Flanges / Valves 100 mm
5.17. CLASS 67 (ACOUSTIC INSULATION + HEAT TRACING)
5.17.1. ACOUSTIC INSULATION TYPE A + HEAT TRACING
Thickness CommentsPiping / Vessels
<= DN200 70 mm> DN200 80 mm
Flanges / Valves 100 mm
5.17.2. ACOUSTIC INSULATION TYPE B + HEAT TRACING
Thickness CommentsPiping / Vessels
<= DN200 85 mm> DN200 95 mm
Flanges / Valves 100 mm
5.17.3. ACOUSTIC INSULATION TYPE C + HEAT TRACING Thickness Comments
Piping / Vessels<= DN200 120 mm> DN200 130 mm
Flanges / Valves 200 mm
Aker Kværner Engineering & TechnologyReport
Title: Doc. No.: Rev.: Page:INSULATION REQUIREMENTS, GUIDELINE
37-1A-AK-R15-00003 04I 15 of 15
5.18. CLASS 68 (ACOUSTIC INSULATION + FIRE PROTECTION OF FLANGES ONLY)
5.18.1. ACOUSTIC INSULATION TYPE A + FIRE PROTECTION OF FLANGES ONLY
Thickness CommentsPiping / Vessels
<= DN150 60 mm> DN150 70 mm
Flanges / Valves 100 mm
5.18.2. ACOUSTIC INSULATION TYPE B + FIRE PROTECTION OF FLANGES ONLY
Thickness CommentsPiping / Vessels
<= DN150 75 mm> DN150 85 mm
Flanges / Valves 100 mm
5.18.3. ACOUSTIC INSULATION TYPE C + FIRE PROTECTION OF FLANGES ONLY
Thickness CommentsPiping / Vessels
<= DN150 110 mm> DN150 120 mm
Flanges / Valves 150 mm