AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto...

16
www.ANNUNCIATOR.ca 3-350 John Street, Thornhill, L3T 5W6, Ontario, Canada Tel.: +1 289 597 2739 Fax: +1 289 597 2200 Email: [email protected] AIWR Series Alarm Annunciator Operation Manual Ver. 2.2.1

Transcript of AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto...

Page 1: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

www.ANNUNCIATOR.ca

3-350 John Street, Thornhill, L3T 5W6, Ontario, CanadaTel.: +1 289 597 2739 Fax: +1 289 597 2200 Email: [email protected]

AIWR Series Alarm Annunciator

Operation ManualVer. 2.2.1

Page 2: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Window Arrangement

MJA

MNA

ON

RST

ACK

HOFF

LT

MJAMNAON

RST ACK HOFF LT

MJAMNAON

RST ACK HOFF LT

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH10

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH16

CH15

CH14

CH13

CH10

CH11

CH12

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9

CH16

CH15

CH14

CH13

CH10

CH11

CH12CH20

CH19

CH18

CH17

10 Channel Alarm Annunciator (AI10WR) 16 Channel Alarm Annunciator(AI16WR)

20 Channel Alarm Annunciator (AI20WR)

Window Dimension (1:1)45 mm

22 mm 22 mm

22 mm

Page 3: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Alarm Channels (Windows): 8, 10, 16, 20 Pushbuttons: Acknowledge, Reset, Test and Mute Flush Mounting Selectable Auto Horn Off Feature Sequence: Code-M of ISA-S18.1 (Manual Reset) with First-up feature Cabinet Size: 144x144mm, 96x96mm Cutout Size: 140x140mm Window Size: 22x22mm, 22x45mm Illumination: Long Life LEDs LED’s Color: Yellow, Red, Green Alarm Labeling: Translucent Film One Logic Controller for four Alarm Points Isolation: Opto Isolated Inputs, Relay Outputs Signal Voltage: 24V, 48V, 110V, 220V, DC or AC Alarm Input: Consumption: 5mA @220VAC Output: Two Dry Contacts Normally Open - Major(Critical) / Minor(Non Critical)0 Output Relays: 1A@240VAC/1.2A@120VAC/1.2A@24VDC Multi-unit Synchronization: Flashing & Auto Horn Off Synchronization Maximum Units of Multi-unit Application: 5 Units Power Supply: 24V, 48V, 110V, 220V (DC or AC)0 Power Consumption: Max. 30 Watts Operating Temperature: -10 to 50 °C Operating Humidity: 0-95% RH, Non Condensing

System Specification

(AC or DC) V1: 24 V2: 48V V3: 110V V4: 220

Signal Voltage(AC or DC) V1: 24 V2: 48V V3: 110V V4: 220

Common (0) :0 Common (+) :1

Input Type

AI 16 WR W V1 1 V1Number of

Alarm Points20 ,16 ,10 ,8

Model Number

Signal Voltage(AC or DC) V1: 24 V2: 48V V3: 110V V4: 220

(AC or DC) V1: 24 V2: 48V V3: 110V V4: 220

Y : YellowR: RedG : Green

Common (0) :0 Common (+) :1

Input Type

Supply Voltage

Options and Order Number

LED Color

Page 4: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

The AIWR Series Alarm Annunciator follows the “Manual Reset” (M) Sequence as listed in the ISA publication Annunciator Sequences and Specification S18.1, 1979 with First-up feature as shown bellow:p

Alarm Sequences

Subsequentto Abnormal

Reset while Normal

Mute

Acknowledge (First-up)

First toAbnormal

Mute

Acknowledge (First-up)

Manual Reset with First-up feature

Legends: P: Process S: Sequence V: Visual A: Audible AA: Alarm Audible RA: Ringback Audible

Reset while Normal

Ack

now

ledg

e

Ack

now

ledg

eP: NormalS: NormalV: OffA: Silent

P: Abnormal S: Subsequent AlarmV: FlashingA: Audible

P: Abnormal or NormalS: First SilencedV: Fast FlashingA: Silent

P: Abnormal S: First AlarmV: Fast FlashingA: Audible

P: Abnormal or NormalS: AcknowledgedV: OnA: Silent

P: Abnormal or NormalS: Subsequent AlarmV: FlashingA: Silent

Page 5: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

FAULT

LAMP

HORN

HORN OFF

ACK.

RESET

B

FAULT

LAMP

HORN

HORN OFF

ACK.

RESET

A

Page 6: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Block Diagram ( 1 )

Common

Clock

Horn Relays

Terminals

Dip switchs

A. H. off

Sequence

Display

Function Keys

Page 7: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Block Diagram ( 2 )

Com.IN-1

IN-10

IN-16

IN-20

SUP. +-

MJA

MN

A

Flashing Sync.

Auto Horn off

Dip

Sw

itchs

Bac

kP

anel

Display

Front Panel Front Panel Front Panel

Function Key

Rea

dy

Indicator

MJAMNA

or

DC AC

+

_

~

~

or

DC AC

+

_

~

~Sup

ply

Jum

per

Set

ting

Inpu

ts

Page 8: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Wiring Diagram

Dip Switches

Back Panel

or

DC

AC

+ _

~ ~

SUP. +-

Fl. Sync.

MJA

MNA

A.H.off Sync.

ExternalPush Buttons

to more Alarm units

or

DC

AC

+ _

~ ~

Com.IN-1

IN-10

IN-16

IN-20

or

DC

AC

+ _

~ ~

DC +_

or

Page 9: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

MNAMJA

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

ON

ON

ON

ON

ON

MJA

MN

A

ON

IN-1

IN - 1 Active

Dip Switch Setting

Select Critical(MJA) / Non-critical(MNA) selector

Back Panel

MJAMNAON

Front Panel

Position (1)

Page 10: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

MNAMJA

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

ON

ON

ON

ON

ON

MJA

MN

A

ON

IN-1

IN - 1 Active

Dip Switch Setting

Select Critical(MJA) / Non-critical(MNA) selector

Back Panel

MJAMNAON

Front Panel

Position (2)

Page 11: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

MNAMJA

1 2 3 4

5 6 7 8

9 10 11 12

14 15 1613

18 19 2017

ON

ON

ON

ON

ON

MJA

MN

A

ON

IN-1

IN - 1 Active

Dip Switch Setting

Select Critical(MJA) / Non-critical(MNA) selector

Back Panel

MJAMNAON

Front Panel

Position (3)

ON

ON

Page 12: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

or

DC

AC

+

_

~

~

SUP. +-

Fl.S

ync.

MJA

MN

A

A.H.of.Sync.

ExternalPush Buttons to

mo

reA

larmu

nits

or

DC

AC

+

_

~

~

SUP. +-

Fl.S

ync.

MJA

MN

A

A.H.of.Sync.

tom

ore

Alarm

un

its

SLAVE

INPUTS INPUTS

Wiring Diagram & Jumper Setting of Multi-unit Application

Flashing Sync.

Auto Horn off

Close (ON) Open (OFF)

Flashing Sync.

Auto Horn off

ON Open

MASTER

Note: Flashing Synchronisation Jumper should be closeed ( ON ) for Single-unit application

Page 13: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Overall Size:

144 mm

144 mm

142 mm

Cutout Size: 140 mm

140 mm

Flush Mouning: By 2 Screw Type Clamps

Page 14: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Note

Page 15: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

We warrant that all products manufactured and sold by us are free from defectsin material and workmanship and those products of our design are fit for thepurpose intended by us when properly installed and wired according to instructionsand national, state and local codes and kept free of dirt and rust.

All products manufactured or sold by us are warranted for a period of twelve (12)months after the product is first in put in to use, or not more than fourteen (14)months after date of shipment, whichever shall expire first, Provided that writtennotice has been given us within thirty (30) days after first discovery of any defects.

The extend of our liability for breach of such warranty, when such is shown to oursatisfaction, and the product has become impaired for the use for which it wasintended by us, shall be limited to the replacement or repair of such product orpart thereof, F.O.B Toronto, Canada.

APEX ANNUNCIATORS assumes no liability for inconvenience or labor costincurred. Goods returned without our authorization will not be accepted.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHERWARANTIES OF FITNESS AND MERCHANTABILITY.

Warranty Policy

Page 16: AIWR Series Alarm Annunciator - Apex Automation · PDF fileCH18 CH17 10 Channel Alarm ... Opto Isolated Inputs, Relay Outputs ... The AIWR Series Alarm Annunciator follows the “Manual

Printed In canada