aisin-as68rc-Tech-Info.pdf

5
8/11/2019 aisin-as68rc-Tech-Info.pdf http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 1/5

Transcript of aisin-as68rc-Tech-Info.pdf

Page 1: aisin-as68rc-Tech-Info.pdf

8/11/2019 aisin-as68rc-Tech-Info.pdf

http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 1/5

Page 2: aisin-as68rc-Tech-Info.pdf

8/11/2019 aisin-as68rc-Tech-Info.pdf

http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 2/5

 

Solenoid application chart with pressure switch states.

All 8 pressure switches are normally “open” meaning they makecontact when there is pressure in the circuit.

Shift sol. 1,2,3 and 4 are normally “closed” on /off solenoids.

Linear sol. “B” is PWM sol. Normally applied.

Linear sol. A,C are PWM sol’s and D are normally vented.

Limp in mode works as follows: if a fault occurs in 4

th

 , 5

th

, or 6

th

 gearunit will fail to 5

th gear until safe to downshift to 3

rd.

If fault occurs in 1st

, 2nd

, or 3rd

 gear unit will fail to 3rd

 gear.

You will always have Reverse.

Page 3: aisin-as68rc-Tech-Info.pdf

8/11/2019 aisin-as68rc-Tech-Info.pdf

http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 3/5

Line pressure testing 

Page 4: aisin-as68rc-Tech-Info.pdf

8/11/2019 aisin-as68rc-Tech-Info.pdf

http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 4/5

Connector pinouts for solenoids and switches

Page 5: aisin-as68rc-Tech-Info.pdf

8/11/2019 aisin-as68rc-Tech-Info.pdf

http://slidepdf.com/reader/full/aisin-as68rc-tech-infopdf 5/5

Pinouts for Range sensor