Airtightness and vapour control layer products - SpanoTech
-
Upload
joyce-verfaillie -
Category
Technology
-
view
111 -
download
2
description
Transcript of Airtightness and vapour control layer products - SpanoTech
Wood based panels Airtightness and vapour control layer
Unilin, division panels As a part of the UNILIN group
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 2
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 3
UNILIN
DIVISION FLOORING
DIVISION PANELS
DIVISION INSULATION
Quick-Step® Laminate
Hardwood
Luxury vinyl
Boards (Chip + MDF)
SpanoTech
Decorative panels
Finished products
Insulated roof panels
Insulated boards
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 4
UNILIN division panels Production sites
Ooigem Oostrozebeke
Izegem
Wielsbeke
Gent
Merchtem
Bazeilles
Manufacturer added value wood based panels
Technical engineering office
Complete solution delivery's TF market
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 5
Introduction SpanoTech
Airtightness Vapour control layer Fire protection Acoustic protection EWP products WF insulation
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 6
Solutions SpanoTech
Thermal performance Insulation
Ventilation Airtightness
A gap as small as 1mm in the vapour barrier can reduce the U-value by a factor of 4.8 Measurement carried out by: Institut Fur Bauphysik, Stuttgart
Crucial for energy efficiency Moisture transfer causes structural damage Air quality Membranes & panels
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 7
Wood based panels in TF buildings Airtightness
Floors, walls, ceiling : 31%!!!
Ducts
Fireplace
Plumbing penetrations
Doors
Windows
Fans & vents
Electric outlets
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 8
Key air leakage points Airtightness
Passive house standard n50 <0.6 1/h
Achieved in TF by interior air barrier system
Panels (tape) & membranes
Sites OSB too air permeable, failure certification
KU Leuven 8 ≠ brands OSB West-Europe
Large variation, OSB passive houses questionable
Solution / repair very expensive (priming, membrane, …)
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 9
Wood based panels – OSB Airtightness
Reliable solution
Topfinish surface
Standard 4 x airtight vs. tested OSB
Racking panel open panel construction
Decking TG 18/22mm
Solutions E1, load bearing in humid conditions
E0 low formaldehyde, application idem
FR fire retardant, application idem (STA listed)
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 10
Wood based panels - Chipboard P5 Airtightness
Large availability
Different characteristics
Glued or stapled
Taped joints
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 11
Membranes Vapour control layer
Vapourblock
Topfinish surface + UV lacquer
Racking panel closed panel construction
Integrated vapour control layer ‘all-in-one’ solution
Stapled, nailed, screwed (glued) + taped
Extremely high airtightness level <0,001 m³/m²/h/Pa at 50Pa
Solutions E1, load bearing in humid conditions
E0 low formaldehyde, application idem
FR fire retardant, application idem
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 12
Wood based panels – Chipboard P5 Vapour control layer
Transformation barn into eco education centre
EnerPHit project Passivhaus Institut
Durélis Vapourblock 12mm
Initial airtightness test : n50 of 0.26 ACH
Details http://www.greenbuildingstore.co.uk
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 13
Stirley community farm – Yorkshire (UK) Case study 1
Renovation project
Concrete frame + TF ‘caissons’
FiberTech Top WF
Durélis Vapourblock
Volume 16.575m³
Critical junctions concrete columns / TF caisson
Air infiltration panels practically zero
n50 0.41 ACH
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 14
Art theatre – Ronse (B) Case study 2
Renovation projects
Volume 431m³
n50 0.11 ACH
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 15
Private houses – Roy (B) / Ireland Case study 3
Open panel : airtightness / racking
Closed panel : airtightness / vapour control / racking
Uniform µ value
Saves installation time and less risk errors/damage
E1, E0 and FR (STA listed)
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 16
Airtightness – Vapour Control layer Conclusion & USP’s
Water vapour transmission
Airtightness
Impact on formaldehyde release
Compatibility with tapes
STA product (Hydroflam FR)
PEFC
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 17
Airtightness – Vapour Control layer Certification & tests
Unilin mission statement
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 18
Practical website www.unilinpanels.com Quickly find your product through the solutions
All product sheets, brochures and DOP’s online
The newest innovation premiered
Everything for your satisfaction
MONDAY, OCTOBER 13, 2014 COPYRIGHT 2014 - ALL RIGHTS RESERVED 19
Service FOCUS ON
Unilin, division panels Ingelmunstersteenweg 229
8780 Oostrozebeke T +32 56 66 70 21 F +32 56 66 82 25
[email protected] www.unilinpanels.com