AIRCooled - dunnair.com.auFast-moving and responsive, Dunnair supplies made-to-measure HVAC...

16
Split Ducted Air Conditioners 6 kW to 200 kW www.dunnair.com.au AIR Cooled

Transcript of AIRCooled - dunnair.com.auFast-moving and responsive, Dunnair supplies made-to-measure HVAC...

Split Ducted Air Conditioners 6 kW to 200 kW

www.dunnair.com.au

AIRCooled

2 www.dunnair.com.au

Dunnair Quality Engineering SolutionsDunnair is now firmly positioned as a leading supplier to the air conditioning industry.

The name Dunnair is synonymous with high quality products in the commercial air-conditioning industry. Beginning with Dunn Air Conditioning in 1961 and more recently, Dunnair International and Dunnair Australia, the company continues to be a leading supplier of air-conditioning units for the Australian market.

In 1994, the company was bought by Multistack and renamed Dunnair International. In 2004, Ernest Ugazio acquired the sales and subsequently state service department of Dunnair. This led to the company being divided into separate entities: Dunnair International and Dunnair Australia, the former focused on Multistack Chiller sales and spare parts; while the latter began design and development of a split ducted and rooftop packaged range that was manufactured in China. More recently, in April 2018, Air Change Group acquired Dunnair Australia, solidifying Dunnair's position as a manufacturer of high quality, specified air conditioning units.

The Air Cooled series of split ducted units shown in this brochure are part of Dunnair’s range of high quality units for every application. Dunnair has also become the first choice when individual engineering solutions are required. Fast-moving and responsive, Dunnair supplies made-to-measure HVAC solutions to a growing number of high profile developments across Australia.

Dunnair research and development plus a strict quality control program have been fundamental to our growth, success and reputation. Dunnair units are manufactured in accordance with strict quality control standards and are MEPS rated and developed for Australian conditions.

Range: Dunnair’s modern factories manufacture 16 separate product lines and some 600 different models. Dunnair can supply most products the HVAC industry requires. The recent acquisition by Air Change, a company known for it's award winning innovation, is proof that the company is working continuously to improve its product range and the efficiency of its products.

Specialised Solutions: Dunnair will engineer and manufacture equipment to suit the application and building design. No challenge will go unaccepted. We will design and make special products as required for the building, mining, transport and maritime industry. We employ mechanical engineers in all sales offices in Australia. Their role is to supporting designers to achieve their goals.

Our promise to system designers is: “Tell us what you need and we will work with you to deliver”.

With a head office in Sydney, Dunnair also has offices in Victoria and Queensland. Dunnair maintains a dedicated engineering and sales support staff waiting to assist you with technical and product information and provide valuable solutions for your project.

Dunnair will design, build and deliver HVAC equipment to meet the most stringent specifications and difficult applications.

“We make special equipment.”

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 3

Features • SHS6 to 35 single stage

• SH40 to 200 two stage

• Optional two stage available for 18 kW to 35 kW

• SHS6 to 35 direct drive

• SH40 to 200 belt drive

• Automatic De-Ice

• Liquid Accumulator

• Dry Filter

• Crankcase heater

• 24 volt control

• Galvanised steel panelling

• Durable powder coated cabinet (outdoor unit)

• External stainless steel fittings

• Easy access panels with turn lock handles, no screws

• 25 mm insulation

• Coil corrosion protection

• High quality scroll compressors

• High/low pressure protection for compressor

• Time delay protection for compressor

• Limit start timer

• Quiet & efficient

• Independent defrost dual circuit units for two stage units

• Phase reverse protection

• Optional electric reheat high temperature protection

• Overload protection for both indoor and outdoor fan motor

• MEPS rated

• Manufactured for Australian Standards & Conditions

• High quality control procedures

• R410a refrigerant is used in standard units. Units with R407c refrigerant are available on request

4 www.dunnair.com.au

Optional FeaturesAs an active market player in the commercial air conditioning industry, we understand that every project is unique. Standard manufactured units may not meet the requirements of your system design.

Dunnair always welcome enquiries for custom made air conditioning equipment.

Available options are listed below:

• Stainless steel condensate tray

• 50 mm insulation

• Electric heating fitted to cooling-only models

• Higher external static pressure up to 500 pa

• Two stages or more dependent on unit size

• Belt drive instead of direct drive fan

• Copper fins

• Vertical fan coil units

• EC motor

• EC plug fan

• Other Customised options available. Please contact your local Dunnair sales office

Optional Controller

DAT – 770 multifunction thermostatTechnologically advanced in design and performance, the DAT – 770 is the ideal thermostat control for any installation of air conditioning systems.

Features include: • Auto season change over

• Select programmable or manual mode

• Heat cool or heat pump (O/B) logic

• 0-10 V output option for heating or cooling

• High & Low balance points

• Single or three-speed fan control

• Keyboard and/or temperature locks

• Occupancy sensor inputs

• Programmable occupancy inputs

• Adaptive recovery (Optimised start)

• Smart fan logic for commercial control

• PIN protected menus (installer PIN)

• Outside air temperature display

• 24 V powered with memory backup

• Volt free (clean contact) relays

• Large backlit EL display

• Remote temperature sensors available

• Integrated Modbus option

• Replaces most 24 V thermostats

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 5

Specifications

Models SHS6 – SH200

Model

Capacities (kW) Nominal Levels

Power Phase

Unit Noise Levels (dBA)

Fan DriveRefrigerant

CircuitsTotal Cooling

Sensible Cooling

HeatingAir Flow

(L/s)

Max Current

(A)Indoor Outdoor

SHS6 5.8 5 5.7 361 11.2

1

47.8 55.5

Direct 1

SHS8 7.8 7.2 7.6 467 10.4 46.5 56.4

SHS10 9.8 8 10.1 611 20.8 48.6 56.7

SHS12 12.2 9.9 12.6 695 14

3

68.4 57.5

SHS15 14.3 13 14.2 840 13.9 61.8 58.2

SHS18 17.2 14.4 17.4 928 16 63.7 59.8

SHS20 19.6 15.7 19.3 1030 17 70.5 73.7

SHS25 24.2 19.3 24.5 1390 22.4 71 74.9

SHS30 30.6 25.4 30.6 1800 25.9 69.8 75.5

SHS35 34.8 28.8 32.4 2000 27.6 70.3 75.3

SH40 39.1 32.6 38 2200 30.8 71.4 75.7

Belt 2

SH45 44.4 36.8 43.5 2700 37.2 72.2 76.2

SH50 48.6 39.8 44.2 2800 41.2 72.8 76.7

SH56 55.6 45 57.4 3000 47.7 72.8 77.1

SH66 65.5 50.9 60.7 3500 54.5 73.1 77.7

SH73 72.8 59.3 66.6 3900 60.6 73.7 78.4

SH80 80.4 65.5 80.7 4300 66.2 74.6 79

SH90 88.5 71 85 4800 74.4 75.5 79.6

SH100 102.2 82.9 98.5 5500 85.2 77 80.6

SH120 117.6 95.2 116.2 6500 98.8 77.1 82.2

SH140 137.8 110.6 132 7500 117.5 77.7 83.3

SH160 156.2 127.5 152.5 8500 133.9 80.1 83.7

SH180 176.8 143.6 169.4 9500 153.2 82.5 85.4

SH200 201.8 164.3 196.2 10500 163.7 82.6 87.2

Cooling Capacity is based on DB 27°C, 19°C WB Entering Air Temperature & 35°C Ambient Temperature

Heating Capacity is based on 21°C DB, Entering Air Temperature

Sound Levels are measured from 1 m of the unit

6 www.dunnair.com.au

Dimensions

Models PHS8–PH200

Model

Outdoor Unit Indoor Unit

Length x Width x Height (mm)

Weight(kg)

Length x Width x Height (mm)

Weight (kg)

SHS6 860 x 310 x 718 65 850 x 620 x 400 50

SHS8 950 x 340 x 840 77 1100 x 620 x 400 56

SHS10 950 x 340 x 840 82 1100 x 620 x 400 58

SHS12 950 x 350 x 950 89 1250 x 620 x 400 65

SHS15 950 x 340 x 1245 105 1400 x 620 x 420 80

SHS18 950 x 340 x 1230 105 1550 x 620 x 420 86

SHS20 950 x 340 x 1230 122 1600 x 620 x 420 90

SHS25 1300 x 950 x 700 241 1650 x 720 x 485 121

SHS30 1300 x 950 x 930 276 1900 x 720 x 485 132

SHS35 1300 x 1000 x 930 282 2100 x 720 x 485 140

SH40 1550 x 1200 x 900 360 1300 x 1200 x 940 220

SH45 1550 x 1400 x 900 365 1500 x 1200 x 940 240

SH50 1800 x 1755 x 910 530 1600 x 1200 x 940 290

SH56 1800 x 1755 x 910 532 1600 x 1200 x 940 290

SH66 1800 x 1755 x 910 535 2000 x 1250 x 1040 410

SH73 1800 x 1755 x 910 538 2000 x 1250 x 1040 412

SH80 1800 x 1803 x 910 615 2200 x 1250 x 1040 485

SH90 1800 x 2080 x 1100 710 2430 x 1350 x 1140 516

SH100 2050 x 2050 x 1350 1100 2150 x 1450 x 1350 620

SH120 2050 x 2050 x 1350 1170 2300 x 1550 x 1550 660

SH140 2050 x 2050 x 1750 1180 2650 x 1600 x 1550 730

SH160 2050 x 2050 x 1750 1250 2850 x 1800 x 1550 760

SH180 2150 x 2200 x 2350 1340 3050 x 1850 x 1650 820

SH200 2150 x 2150 x 2350 1400 3050 x 1850 x 1650 860

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 7

Fan Curves

Air Handling Performance

Nominal Airflow

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

280 320 360 400 440Airflow

(L/s)

50

100

150

250

200

High

Medium

Low

SHS6

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

390 430 470 510 550

50

100

150

250

200

High

Medium

Low

SHS8

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

430 470 510 550 590

50

100

150

250

200

High

Medium

Low

SHS10

High

Medium

Low

500 600 700 800 900

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

50

100

150

250

200

SHS12

640 740 840 940 1040

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

50

100

150

250

200

High

Medium

Low

SHS15

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

730 830 930 1030 1130

50

100

150

250

200

High

Medium

Low

SHS18

8 www.dunnair.com.au

High

Medium

LowExte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

630 830 1030 1230 1430

50

100

150

250

200

SHS20

50

100

150

200

300

250

990 1190 1390 1590 1790

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal AirflowSHS25

1400 1600 1800 2000 2200

50

100

150

200

300

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal AirflowSHS30

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

1600 1800 2000 2200 2400Airflow

(L/s)

Nominal Airflow

50

100

150

200

300

250

SH35

50

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

1600 1800 2000 2200 2400 2600 2800Airflow

(L/s)

Nominal Airflow

2.2 kW Motor Limit

SH40

50

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

2100 2300 2500 2700 2900 3100 3300Airflow

(L/s)

Nominal Airflow

3.0 kW Motor Limit

SH45

Fan Curves

Air Handling Performance

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 9

50

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

2200 2400 2600 2800 3000 3200 3400Airflow

(L/s)

Nominal Airflow

3.0 kW Motor Limit

SH50

50

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

2400 2600 2800 3000 3200 3400 3600Airflow

(L/s)

Nominal Airflow

4.0 kW Motor Limit

SH56

50

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

3100 3300 3500 3700 3900 4100 4300Airflow

(L/s)

Nominal Airflow

4.0 kW Motor Limit

SH66

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

4.0 kW Motor Limit

3400 3500 3800 4000 4200 4400 4600

50

100

150

200

300

350

400

250

SH73

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

4.0 kW Motor Limit

3500 3700 3900 4100 45004300 4700 51004900

SH80450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

5.5 kW Motor Limit

4200 4400 4600 4800 52005000 5400 58005600

SH90

10 www.dunnair.com.au

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

Airflow(L/s)

Nominal Airflow

7.5 kW Motor Limit

4400 4675 4950 5225 57755500 6050 66006325

SH100 Nominal Airflow

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

5200 5525 5850 6175 68256500 7150 78007475Airflow

(L/s)

7.5 kW Motor Limit

SH120

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

3200 4500 5500 6500 7500 95008500 10500 11500Airflow

(L/s)

Nominal Airflow

11 kW Motor Limit

SH140 Nominal Airflow

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

4500 5500 6500 7500 8500 105009500 11500 12500Airflow

(L/s)

15 kW Motor Limit

SH160

450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

5500 6500 7500 8500 9500 1150010500 12500 13500Airflow

(L/s)

Nominal Airflow

15 kW Motor Limit

SH180450

100

150

200

300

350

400

250

Exte

rnal

Sta

tic

Pre

ssur

e(P

asca

ls)

6500 7500 8500 9500 10500 1250011500 13500 14500Airflow

(L/s)

Nominal Airflow

15 kW Motor Limit

SH200

Fan Curves

Air Handling Performance

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 11

Wiring Diagrams

KM1-3 Contactor

TR Transformer

PU1/2/3 Fuse

PRF Phase Protection

DF1 De ice

VAR Varistor

KT1 Time Relay

C1–3 Capacitor

KA1 Fault Relay

RC1-3 Filter

RV1 Reversing valve

HP/LP HP/LP switch

CM1 Compressor

FM1 Condenser fan

EM Evaporator fan

SH1 Sump heater

BR1 Bypass Relay

SHS6–10

SHS12–20

Outdoor Unit

L1NE

H1M1

W1

CMW

C2

U

FM1

Black

RedBrownBlue

Earth electrode

U1

L1

EN

H1

Indoor Unit

M1

240V50HZ

KM1 KA2

E

PU1

C1

PU2L21

24V

θ PU3KM1SH1

AC100

HP

RV1

BR1

H

KM1

RHRH

RM

T

CKT1

1

12

12

3

2 6

RM

VAR

RLRL

NC COM

M1N

DF1

BR1 105 9

A1 A2

A1 A2

A B

A B

A B

A B

L1M1

C3EMH1

RL

RMRH

N

6

54

6

54

6

5 LP5

L

RC1

1P

KA2

KM1

Outdoor Unit

L1NE

H1M1

W1

CMWU

FM1

Black

RedBrownBlue

Earth electrode

U1V1

L1

EN

H1

Indoor Unit

M1

240V50HZ

KM1

W

C2

U

FM2

KA2

E

ABCN

PU1

C1

PU2L21

24V

θ PU3KM1SH1

AC100

HP

TR

RV1

BR1

H

KM1

RHRH

RM

T

CKT1

1

13

7

73

2 6

RM

VAR

RLRL

NC COM

M1N

DF1

BR1 10

13 14

A1 A2

A1 A2

A B

A B

A B

A1 A2

L1M1

C3EMH1

RL

RMRH

N

6

54

6

5

5

9

6

10

3

4

1

2

6

54

6

5LP5

L

RC1

1P

KA2

KM1

PRF

PRFL1 L2 L3

com

on

12 www.dunnair.com.au

SHS25–35

QF1-3 Motor Overload Breaker

KM1-5 Contactor

FR Thermal Relay

TR Transformer

PU1/2/3 Fuse

DF1/DF2 De ice

VAR Varistor

KT1-2 Time Relay

PRF Phase Protection

C1- 3 Capacitor

KA1-2 Fault Relay

RC1-5 Filter

RV1/RV2 Reversing valve

TK1-4 Overload protector

TK5-6 Disch temp sensor

L/HP1 HP/LP switch

CM1-2 Compressor

FM1-4 Condenser fan

EM Evaporator fan

SH1-2 Sump heater

BR1-2 Bypass Relay

Outdoor Unit

WE

UV

WE

UV

W1

CM1 FM1

RedWhiteBlue

RedWhiteBlue

Earth electrode

U1V1

W3U3V3

Indoor Unit

KM1KM3

QF1Set:16AE

ABCN

PU1PU2

L21

24V

θ PU3KM1SH1

AC100

HP1

TR

RV1

KM1

H1

T

C1KT1

TK11

13

18

21

12

12

5

VAR

NC COM

M1N

DF1

BR1 14

KM2

SH2 101

13 14

1 3A1 A26

5

3

4

1

26

5

3

4

1

2

LP17

L

RC1KM1

PRF

VU W

PRF

FR

L1 L2 L3

com

on

Three phase five line415V 50Hz 3P

W2

CM2 FM2

EM

U2V2

W4U4V4

KM2KM4

QF2

QF3

Set:16A

Set:5A

6

5

3

4

1

26

5

3

4

1

2

6

5

3

4

1

2

21

22

21

22

HP2C2KT2

TK22 22

3 9

61 3

6 10

A1 A2LP28

RC2KM2

A1 A2

A1 A2

BR2A1 A2

RC3KM3

RV2

KM2

H2

EF

12

NC COM

M2N

DF2

BR2 16

13 14

L

4 15

6 10

A1 A2

A1 A2

BR2A1 A2

RC4KM4

A1 A2

RC5KM5

Wiring Diagrams

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 13

SH40-45

QF1-3 Motor Overload Breaker

KM1-5 Contactor

FR Thermal Relay

TR Transformer

PU1/2/3 Fuse

DF1/DF2 De ice

VAR Varistor

KT1-2 Time Relay

PRF Phase Protection

C1- 3 Capacitor

KA1-2 Fault Relay

RC1-5 Filter

RV1/RV2 Reversing valve

TK1-4 Overload protector

TK5-6 Disch temp sensor

L/HP1 HP/LP switch

CM1-2 Compressor

FM1-4 Condenser fan

EM Evaporator fan

SH1-2 Sump heater

BR1-2 Bypass Relay

Outdoor Unit

WE

UV

WE

UV

W1

CM1 FM1

RedWhiteBlue

RedWhiteBlue

Earth electrode

U1V1

W3U3V3

Indoor Unit

KM1KM3

QF1Set:17AE

ABCN

PU1PU2

L21

24V

θ PU3KM1SH1

AC100

HP1

TR

RV1

KM1

H1

T

C1KT1

TK11

13

18

21

12

12

5

VAR

NC COM

M1N

DF1

BR1 14

KM2

SH2 101

13 14

1 3A1 A26

5

3

4

1

26

5

3

4

1

2

LP17

L

RC1KM1

PRF

VU W

PRF

FR

L1 L2 L3

com

on

Three phase five line415V 50Hz 3P

W2

CM2 FM2

EM

U2V2

W4U4V4

KM2KM4

KM5QF2

QF3

Set:17A

Set:6.8A

6

5

3

4

1

26

5

3

4

1

2

6

5

3

4

1

2

21

22

21

22

HP2C2KT2

TK22 22

3 9

61 3

6 10

A1 A2LP28

RC2KM2

A1 A2

A1 A2

BR2A1 A2

RC3KM3

RV2

KM2

H2

EF

12

NC COM

M2N

DF2

BR2 16

13 14

L

4 15

6 10

A1 A2

A1 A2

BR2A1 A2

RC4KM4

A1 A2

RC5KM5

13

14

14 www.dunnair.com.au

QF1-3 Motor Overload Breaker

KM1-5 Contactor

FR Thermal Relay

TR Transformer

PU1/2/3 Fuse

DF1/DF2 De ice

VAR Varistor

KT1-2 Time Relay

PRF Phase protection

KA1-2 Intermediate relay

KA3-4 Fault Relay

RC1-5 Filter

RV1/RV2 Reversing valve

TK1-4 Overload protector

TK5-6 Disch. temp. sensor

L/HP1-2 HP/LP switch

CM1/CM2 Compressor

FM1-4 Condenser fan

EM Evaporator fan

SH1-2 Sump heater

BR1-2 Bypass Relay

SH50–73

Outdoor Unit

WE

UV

WE

UV

W1

CM1 FM1

RedWhiteBlue

RedWhiteBlue

Earth electrode

U1V1

W3U3V3

Indoor Unit

KM1 KM3

QF1E

ABCN

PU1PU2

L21

24V

θ PU3

KM1

SH1

AC

100

HP1

TR

RV1

KM1

H1

T

C1KT1

TK11

13

18

21

12

12

23 25

VAR

NC COM

M1N

DF1

BR1 14

KM2 KA1 KA2

SH2101

13 14

1 3A1 A26

5

3

4

1

2

6

5

3

4

1

2

LP15

L

KA1

PRF

VU W

PRF

FR

L1 L2 L3

FM2W3U3

V3

FM4W4U4

V4

com

on

13

14

Three phase five line415V 50Hz 3P

W2

CM2 FM3

EM

U2V2

W4U4V4

KM2 KM4

KM5QF2

QF3

Set:24.5ASet:24.5A

Set:11.6A

6

5

3

4

1

2

6

5

3

4

1

2

6

5

3

4

1

2

21

22

21

22

5

9

5

9

TK2 TK5

HP2KT2

TK32 22 24 25

19 20

1 3A1 A2LP26

7

8KA2

TK4 TK6C2

3 9

6 10

A1 A2

A1 A2

BR2A1 A2

RC3

RC1 RC2

KM3

RV2

KM2

H2

EF

12

NC COM

M2N

DF2

BR2 16

13 14

L

4 15

6 10

A1 A2A1

A2

A1

A2

A1 A2

BR2A1 A2

RC4KM4

A1 A2

RC5KM5

KM1 KM2

Wiring Diagrams

Air Cooled Split Ducted Air Conditioners

www.dunnair.com.au 15

QF1-3 Motor Overload Breaker

KM1-5 Contactor

FR Thermal Relay

TR Transformer

PU1/2/3 Fuse

DF1/DF2 De ice

VAR Varistor

KT1-2 Time Relay

PRF Phase Protection

KA1-2 Intermediate relay

KA3-4 Fault Relay

RC1-5 Filter

RV1/RV2 Reversing valve

TK1-4 Overload protector

L/HP1-2 HP/LP switch

CM1 /CM2 Compressor

FM1-4 Condenser fan

EM Evaporator fan

SH1-2 Sump heater

BR1-2 Bypass Relay

TK5 Compressor protect

SH80–200

W1

CM1 FM1U1

V1W3U3

V3

KM1FR1 FR2

KM3

QF1E

ABCN

PU1PU2

L21

24V

θ PU3

KM1

SH1

AC

100

HP1

TR

RV1

KM1

H1

T

C1KT1

TK11

13

18

21

12

12

23 25

VAR

NC COM

M1N

DF1

BR1 14

KM2 KA1 KA2

SH2101

13 14

1 3A1 A26

5

3

4

1

2

6

5

3

4

1

2

LP15

L

KA1

PRF

V5U5 W5

V5U5 W5

PRF

FR

L1 L2 L3

FM2W3U3

V3

FM4W4U4

V4

com

on

13

14

Three phase five line415V 50Hz 3P

W2

CM2 FM3U2

V2W4U4

V4

KM2 KM4

KM5

KM7

KM6

QF2

QF3

Set:37ASet:37A

Set:11.6A

6

5

3

4

1

2

6

5

3

4

1

2

6

5

3

4

1

2

21

22

21

22

5

9

5

9

TK2 TK5

HP2KT2

TK32 22 24 25

19 20

1 3A1 A2LP26

7

8KA2

TK4 TK6C2

3 9

6 10

A1 A2

A1 A2

BR2A1 A2

RC3

RC1 RC2

KM3

RV2

KM2

H2

EF

12

NC COM

M2N

DF2

BR2 16

13 14

L

4 15

6 10

A1 A2

A1

L1 L2

L21

L3

L N

N

B1 B2

26 6

11M2

A2

A1

A2

A1 A2

BR2A1 A2

RC4KM4

A1 A2

RC5KM5

A1 A2

RC7KM7

KM1 KM2

Outdoor Unit

WE

UV

WE

UV

RedWhiteBlue

RedWhiteBlue

RedWhiteBlue

Earth electrode

Indoor Unit

EM

W

UV

W

UV

RedWhiteBlue

6

5

3

4

1

2

6

5

3

4

1

2

KT3309 211

KM631

32

22

A1 A2

RC6KM6

KT3KT3TK6 339 215

KM7

S6

3422

31KM6

32

13KM6

14

13 14SY380 Overload Protector inner compressor

240V AC

L1 L2

L21

L3

L N

N

B1 B2

25 6

11M2

TK5

240V AC

www.dunnair.com.au

201808DUNACRTP

DUNNAIR (Aust) Pty Ltd

Head Office:Ashford Avenue, Milperra NSW 2214 p 02 8774 1403 f 02 8774 1490 e [email protected] w www.dunnair.com.au

Dunnair Victoria:p 03 9558 7001 f 03 9551 1644 e [email protected]

Dunnair Queensland:p 07 3890 8796 f 07 3890 8642 e [email protected]

For sales in SA, NT or WA please contact our distributor Industrial Air on 08 8354 0088

Dunnair (Aust) Pty Ltd supports a policy of continuous product improvement. Therefore specification and designs are subject to change without prior notice. Dunnair (Aust) Pty Ltd accepts no responsibility for possible errors in Catalogues, brochures and other printed material.Dunnair is part of the Air Change Group of companies.