Air21 Omt Readme

37
OMT – Operation & Maintenance Terminal (CXP 104 0015/6) OMT Version: P49H

Transcript of Air21 Omt Readme

  • OMT Operation & Maintenance Terminal

    (CXP 104 0015/6)OMT Version: P49H

  • 1 Release Notes

  • 2 P49H(CXP 104 0015/6)

    1.1 New functions

    Configurable Antenna System Voltage

    AIR as one unit

    1.1.1 Modified functions

    Create IDB: Support Antenna System Voltage in Create IDB

    Install IDB: Display information when Antenna System Voltage 12V or 17V TMA is defined in IDB

    Display RU Information: For the chosen RE Display Antenna System Voltage

    Define ALNA_TMA Parameters: Support for Antenna System Voltage

    1.1.2 New views

    1.1.1 Modified views

    AIR as one unit

    1.1.3 New configurations

    Configurable Antenna System Voltage: New system device type and voltage

    1.1.4 New monitors

    1.1.5 R48S(CXP 104 0015/5)

    1.1.6 New functions

    Battery test

    Support for DUG20 R3A and on

    Function "Load Flash Card" loads complete SW also for DUG 20 R3A and on. Older OMT loads incomplete SW, and additional SW download from BSC therefore takes place

  • Support System upgrade

    1.1.7 Modified functions

    Basic mixed mode enhancements

    1.1.8 New views

    1.1.9 Modified views

    1.1.10 New configurations

    Support for RRUS 12 (Dual TX):

    Single mode: Added RBB 22 1b, RBB 42 2d and RBB 44 2c Mixed mode: Added RBB 22 2c and RBB 42 4a

    Support for AIR 11(shown as RRUS 01 in OMT):

    Using configurations with RBB 11 1a/RBB 11 1b and new RBB 22 2g

    Support for AIR 21(shown as RRUS 01 in OMT): Using configurations with RBB 12 1a/RBB 12 1b and new RBB 24 2c

    Support for RBS 6101 and RBS 6102 as Main Unit. The RBS is equipped with RRUS only. Refer to HW documentation for

    more information.

    Support for RBS 6101, RBS 6102, RBS 6201 and RBS 6202 as Hybrid

    The RBS is equipped with RUS and RRUS. Refer to HW

    documentation for more information.

    1.1.11 New monitors

    BFU Battery Fault LED

    VSWR at TX Antenna with port B

    TMA current at port B

    Battery Test Running

    Battery Test Status

  • R47B (CXP 104 0015/4)

    1.1.2 New functions Display Combined Cell Configuration

    1.1.3 Modified functions Create IDB: Added choice for Internal Cascaded RBB

    1.1.4 New views -

    1.1.5 Modified views -

    1.1.6 New configurations Support for RRUS Cascading

    1.1.7 New monitors -

    R45M (CXP 104 0015/2)

    1.1.12 New function

    Clear Technician Present

    1.1.13 Modified function

    Change Maintenance Mode

    1.1.14 New configurations Support for RUS02 (Up to 8 TRXs) Support for AIR (Requires BTS SW G12B or later)

    1.1.15 New monitors Fault Status Monitor for MCTR (Multi Carrier Transmitter Receiver)

    Actual Power Capacity in RUS

    P1B (CXP 104 0015/1)

  • 1.1.16 New views

    Radio equipment setup view.

    1.1.17 New function

    Support for Mixed mode.

    1.1.18 Modified function

    Define Node Parameters

    o Define hub position for support systems

    o R42H

    1.2 New Configurations

    Support for RBS 6301

    o One sector single band uncombined and combined configurations: 1x2, 1x4

    o One sector dual band uncombined and combined configurations: 2|2 and 2|4

    o Two sector single band uncombined and combined configurations: 2x2, 2+4 and 2x4

    o Two sector dual band uncombined and combined configurations: 2x2|2x2 and 2x4|2x2

    o Three sector single band uncombined and combined configurations: 2+2+4, 2+4+4, 3x2 and 3x4

    o Three sector dual band uncombined and combined configurations: 3x2|3x2

    o Four Way Receiver Diversity configurations:

    1x2, 2x2 and 3x2

    1.2.1 New views

    RBS 6301 cabinet view and radio view.

    1.2.2 New function

    Support for Windows 7.

  • R41H

    1.2.3 New Configurations

    Support for RBS 6102 V1 RUG

    o One sector single band uncombined and combined configurations: 1x2, 1x4

    o One sector dual band uncombined and combined configurations: 2|2 and 2|4

    o Two sector single band uncombined and combined configurations: 2x2, 2+4 and 2x4

    o Two sector dual band uncombined and combined configurations: 2x2|2x2 and 2x4|2x2

    o Three sector single band uncombined and combined configurations: 2+2+4, 2+4+4, 3x2 and 3x4

    o Three sector dual band uncombined and combined configurations: 3x2|3x2

    o Four Way Receiver Diversity configurations:

    1x2, 2x2 and 3x2

    Support for RBS 6202 and RBS 6101 RUG

    o One to six sector configurations.

    Support for Left and Right adjusted RUG configurations

    o One sector uncombined and combined configurations: 1x2.

    o Two sector uncombined and combined configurations: 2x2.

    o Three sector uncombined and combined configurations: 3x2.

    1.2.4 New views

    RBS 6102 V1 RUG cabinet view and radio view.

    RBS 6202 cabinet view and radio view.

    1.2.5 New Monitors

    Fan fault LED.

  • R40J

    1.2.6 New Configurations

    RBS 6101, RBS 6102, RBS 6201 and RBS 6601: configurations up to:

    o 6x4 Single TX

    o 3x8 Dual TX

    o 3x12 Tripple TX

    o 3x16 Quad TX

    o Support for all frequencies

    o Support for 4-way receiver diversity

    o Support for symmetric and asymmetric number of carriers between the sectors

    1.2.7 New views

    RBS 6101 cabinet view and radio view.

    RBS 6102 cabinet view and radio view.

    RBS 6601 cabinet view and radio view.

    Note: New view handling for RBS 6000. If the position for an RU is not defined the unit will not be shown in the cabinet view. To set RU position use function Define RU position.

    1.2.8 New function

    Define RU position for RBS 6000 configurations.

    Define CPRI parameters

    Define MCTR configuration

    Define Node parameters

    Display MCTR Configuration

    Display TRXC HW Allocation

    1.2.9 Modified function

    Defined external nodes are displayed in the System view

  • Create IDB: RBS Configuration wizard can be started from the Final Configuration Selection window of Create IDB

    Create IDB for RUS/RRUS configurations:

    o Parameter setting for all antenna sectors is moved to one dialog.

    o Mapping of TRXs to MCTRs are part of Create IDB

    1.2.10 New monitors

    VSWR at TX Antenna for RUS/RRUS

    RI[A] RI[F] LEDS for DUG 20

    R39H

    1.2.11 New Configurations

    Support for RBS 6201 V2

    o One sector single band uncombined and combined configurations: 1x2, 1x4

    o One sector dual band uncombined and combined configurations: 2|2 and 2|4

    o Two sector single band uncombined and combined configurations: 2x2, 2+4 and 2x4

    o Two sector dual band uncombined and combined configurations: 2x2|2x2 and 2x4|2x2

    o Three sector single band uncombined and combined configurations: 2+2+4, 2+4+4, 3x2 and 3x4

    o Three sector dual band uncombined and combined configurations: 3x2|3x2

    o Four Way Receiver Diversity configurations:

    1x2, 2x2 and 3x2

    RBS 2107 supports the same configurations as RBS 2207.

    1.2.12 New views

    RBS 6201 V2 cabinet view and radio view.

  • 1.2.13 New function

    Define Power and Battery

    1.2.14 Modified function

    Define Alarm Inlets

    Load Flash Card

    1.2.15 New monitors

    PDU Information

    PDU Voltage

    GPS Signal to noise ratio

    R38C

    1.2.16 New function

    Multiple CCCH

    Monitor TS Channel Combination updated.

    Display Paging Queue status updated, added monitors for timeslot number 2, timeslot number 4 and timeslot number 6.

    R37A

    1.2.17 New function

    Support for Windows Vista.

    1.2.18 Modified function

    Define Delay for ESB, reduced the value range for TG Instance. New value range is 0-511.

    R36_5

    1.2.19 New function

    Improved OMT information regarding additional active OMT connection

  • o OMT and ROMT is updated with the same warning/information as ROMTIP when trying to connect to a RBS where a connection has already been established.

    New Lost Frame and Buffer Delay Measurements for Packet ABIS.

    o Monitor Super Channel Quality is updated, see the online help for more information.

    Check Battery Backup Time

    1.2.20 Modified function

    Create IDB

    o STN Equipment item PSTU is removed.

    o STN Equipment item SIU is removed for RBS 2101, RBS 2102, RBS 2103, RBS 2202, RBS 2301, RBS 2302 and RBS 2401.

    Define Battery Parameters is not possible to select in mixed configurations

    PF Passive data is also checked in Check IDB function

    1.2.21 New monitors

    Fast Antenna Hopping Table

    1.2.22 Modified function

    Define Battery Backup Time Test

    o The date and time for the next battery backup time test will be shown.

    o The test result for the previous test, and how long time the test was executed before it was stopped will be shown.

    o The input of the stop level system voltage for the backup time test will be removed.

    o R35_7

    1.2.23 New Configurations

    Support for RBS 2116 V2 and RBS 2216 V2 (Same configurations as RBS 2x16).

  • Support for RBS 2111 V2, GSM 800/900/1800/1900

    o One sector uncombined configurations: 1x2, 1x4, 1x6 and 1x2 with splitter (Highway coverage).

    o One sector EHCU combined configurations: 1x4 and 1x6

    o Two sector uncombined configurations: 2x2, 2+4 and 4+2 single and dual band

    o Two sector mixed uncombined and EHCU combined configurations: 2+4 and 4+2 single and dual band

    o Antenna sharing with other RBS 2111 V2 EHCU combined configurations: 2+4 and 4+2 single and dual band.

    o Three sector uncombined configurations: 3x2 single and dual band.

    RBS 2111

    o One sector uncombined configurations: 1x2 with splitter (Highway coverage).

    RBS 2106, RBS 2106i, RBS 2106 V3, RBS 2206 and RBS 2206 V2 CDU-K configurations

    o One sector uncombined and combined configurations: 1x2, 1x4, 1x6.

    o Two sector uncombined and combined configurations: 2x2 and 2x4.

    o Three sector uncombined and combined configurations: 3x2.

    o Three sector combined configurations: 3x4.

    1.2.24 New views

    RBS 2116 V2 and RBS 2216 V2 cabinet views.

    RBS 2111 V2, radio view.

    1.2.25 Modified views

    Radio views have been updated to display four and six sector configurations correct.

    RBS 2111, added splitter to radio view.

  • 1.2.26 Modified functions

    Display Log, a more detailed log is supported if present in the RBS.

    Create IDB. Support for SIU.

    Check IDB. UC/HC manual switch position is checked against IDB.

    Display HW Information. UC/HC manual switch position is reported.

    Display Status. Added Uncomb LED status.

    Display IDB info have been updated to display four and six sector configurations correct.

    Timeouts have been removed on all operations communicating with the RBS. The user can cancel an ongoing operation.

    OMT installation. Menu shortcuts are removed correctly on uninstall.

    OMT performance enhancement.

    o Memory usage for the OMT application has been reduced.

    o Start-up time for the OMT application has been reduced.

    o R34_10

    1. Modified functions

    Added missing pictures in the online help.

    2. Modified views

    Radio view for RBS 2116 and RBS 2216:

    o Port names on the splitter corrected.

    o R34_9

    1.2.27 Modified functions

    Check IDB:

    o Support for RBS 2116.

    o Faulty number of DRU is displayed now.

    Memory usage of OMT is reduced.

    Create IDB dialog:

  • o New button Display Detected HW Info added.

    o Radio button Detected HW Info was removed.

    Define Antenna Supervision now also in connected state.

    On-line help for Super Channel Quality monitor.

    RF Loop test monitors. The following monitors were removed:

    o Monitor RF Loop Test BER

    o Monitor RF Loop Test - Burst Q A

    o Monitor RF Loop Test - Burst Q B

    o Monitor RF Loop Test - RX level A

    o Monitor RF Loop Test - RX level B

    Check IDB, added a control between the IDB and the RBS SW capabilities.

    On-line help and description in monitor window for Super Channel Quality monitor.

    Create IDB dialog box.

    1.2.28 New function

    Improved PM for Packet Abis

    1.2.29 Modified views

    Radio view for RBS 2308:

    o Tool tip on connection points with port names.

    o Show Cable info in Radio view.

    1.2.30 New Configurations

    RBS 2116, RBS 2216 GSM 900 and GSM 1800. The following configurations are introduced:

    o One sector combined configurations without RXS with optional TMA: 1x8, 1x10, 1x12

    o Two sector combined configurations without RXS with optional TMA: 2+8, 4+8, 8+2, 8+4

    o Two sector mixed uncombined and combined configurations without RXS with optional TMA: 2+8, 4+8, 8+2, 8+4

  • o Three sector combined configurations without RXS with optional TMA: 2+2+8, 8+2+2, 4+2+6, 6+2+2, 6+2+4, 6+2+2.

    o Three sector mixed uncombined and combined configurations without RXS with optional TMA: 2+2+8, 8+2+2, 4+2+6, 6+2+2, 6+2+4, 6+2+2.

    o Three sector mixed uncombined and combined configurations with RXS with optional TMA: 2+2+8, 8+2+2.

    o Three sector dual band uncombined configurations without RXS with optional TMA: 3x2|3x2.

    o Three sector dual band combined configurations without RXS with optional TMA: 2+2+4|2+2+0, 2+4+2|2+0+2, 4+2+2|0+2+2, 2+4+4|2+0+0, 4+4+2|0+0+2, 4+2+4|0+2+0, 3x2|3x2.

    o Three sector dual band mixed uncombined and combined configurations without RXS with optional TMA: 2+2+4|2+2+0, 2+4+2|2+0+2, 4+2+2|0+2+2, 2+4+4|2+0+0, 4+4+2|0+0+2, 4+2+4|0+2+0, 3x2|3x2, 2+3+3|2+0+2, 3+3+2|0+2+2.

    RBS 2116, RBS 2216 GSM 900 and GSM 1800. The following configurations are introduced:

    o Four sector single band uncombined and combined configurations with optional TMA: 4x2.

    o Four sector single band mixed uncombined and combined configurations with optional TMA: 4+2+2+4, 4+4+2+2, 2+2+4+4.

    Six sector single band combined and uncombined configurations with optional TMA: 6x2.

    CDU-G in RBS 2x07, RBS 2112 and RBS 2204.

    R33_7

    1.2.31 New function

    Define Antenna Supervision

    RBS Multi TG support

    1.2.32 New monitors

    RX path imbalance

    1.2.33 Modified functions

    Define PCM renamed to Define Transmission

  • Selection of STN equipment added in Create IDB dialog

    Define Present RUs, support for RBS 3018 in RBS 2106 cabinet

    1.2.34 New Configurations

    RBS 2111 GSM 900 and GSM 1800

    o Single band configuration uncombined: 1x4, 1x6, 2+4, 4+2

    o Dual band configuration uncombined: 2+4, 4+2

    o Single band configuration combined in first sector uncombined in second sector: 4+2

    o Single band configuration uncombined in first sector combined in second sector: 2+4

    o Single band configuration combined with sharing: 2+4, 4+2

    o Dual band configuration combined with sharing: 2+4, 4+2

    RBS 2106V3 Support.

    CDU-K in RBS 2106, RBS 2106i, RBS 2106V3, RBS 2206 and RBS 2206V2.

    R32_7

    1.2.35 New functions

    RBS 2216 E-GSM

    1.2.36 New Configurations

    RBS 2216 GSM 900 and GSM 1800

    o Single band configuration mix of combined and uncombined with and without TMA in all sectors independently:2+4, 4+2

    o Single band splitter configuration mix of combined and uncombined with and without TMA in all sectors independently:2+10, 10+2

    o Dual band configuration mix of combined and uncombined with and without TMA in all sectors independently:2+4, 4+2, 2+2+4, 2+4+2, 4+2+2, 4+4+2, 4+2+4, 2+4+4, 2x4|2x2

  • o Dual band splitter configuration mix of combined and uncombined with and without TMA in all sectors independently:2+10, 10+2, 2+2+4, 2+4+2, 4+2+2, 4+4+2, 4+2+4, 2+4+4, 2x4|2x2

    o R32_6

    1.2.37 New Configurations

    RBS 2216 GSM 900 and GSM 1800

    o Single band uncombined configurations:1x2, 1x4, 1x6, 2x2, 2+3+3, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 3+3+2, 4+2+2, 4+2+4, 4+4+2 with and without TMA in all sectors independently2+4, 2+6, 2+2+4, 3+3+4 with optional TMA in first sectors and with or without TMA in last sector4+2, 6+2, 4+2+2, 4+3+3 with or without TMA in first sector and optional TMA in other sectors2+4+2 with or without TMA in second sector, and optional TMA in other sectors2+4+4 with optional TMA in first sector and with or without TMA in other sectors4+2+4 with optional TMA in second sector and with or without TMA in other sectors4+4+2 with optional TMA in third sector and with or without TMA in other sectors2x4, 4+6, 6+4, 3x4 without TMA in any sector2x4, 4+6, 6+4, 2x6, 3x4 with TMA in all sectors2x4, 4+6, 6+4, 2x6, 3x4 with TMA in first sector and without TMA in other sectors3x4 with and without TMA in first and third sector and with TMA in second sector2x4, 4+6, 6+4, 2x6, 3x4 without TMA in first sectors and with TMA in last sector3x4 with TMA in first sectors and without TMA in last sector3x4 without TMA in first sector and with TMA in other sectors

    o Single band uncombined splitter configurations:1x4, 1x6, 2x4, 2x6, 2+4, 2+6, 2+2+4, 2+3+3, 2+4+2, 2+4+4, 3x4, 3+3+2, 3+3+4, 4+2, 4+6, 4+2+2, 4+2+4, 4+4+2, 4+3+3, 6+2, 6+4 with and without TMA in all sectors independently4+6 without TMA in first sector and optional TMA in second sector4+6 with TMA in first sector and optional TMA in second sector

  • o Single band combined configuration with and without TMA in all sectors independently:1x2, 1x4, 1x6, 1x8, 1x10, 1x12, 2x2, 2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4

    o Single band combined splitter configuration with and without TMA in all sectors independently:1x2, 1x4, 1x6, 1x8, 1x10, 1x12, 2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4

    o Single band configuration mix of combined and uncombined with and without TMA in all sectors independently:2+3+3, 3+3+2, 3+3+4, 4+3+3

    o Single band splitter configuration mix of combined and uncombined with and without TMA in all sectors independently:2+3+3, 3+3+2, 3+3+4, 4+3+3

    o Single band 4-way receiver diversity configurations with TMA:1x4, 2x4, 3x4

    o Single band 4-way receiver diversity splitter configurations with TMA:1x2, 2x2, 2+2+4, 2+4+2, 2+4+4, 3x2, 4+2+2, 4+2+4, 4+4+2

    o Single band RX antenna sharing configurations with TMA:4+8

  • o Dual band uncombined configurations:2x2, 2+3+3, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 3+3+2, 4+2+2, 4+2+4, 4+4+2, 2x2|2x2, 3x2|3x2 with and without TMA in all sectors independently2+4, 2+6, 2+2+4, 3+3+4 with optional TMA in first sectors and with or without TMA in last sector4+2, 6+2, 4+2+2, 4+3+3 with or without TMA in first sector and optional TMA in other sectors2+4+2 with or without TMA in second sector, and optional TMA in other sectors2+4+4 with optional TMA in first sector and with or without TMA in other sectors4+2+4 with optional TMA in second sector and with or without TMA in other sectors4+4+2 with optional TMA in third sector and with or without TMA in other sectors2x4, 4+6, 6+4, 3x4 without TMA in any sector2x4, 4+6, 6+4, 2x6, 3x4 with TMA in all sectors2x4, 4+6, 6+4, 2x6, 3x4 with TMA in first sector and without TMA in other sectors3x4 with and without TMA in first and third sector and with TMA in second sector2x4, 4+6, 6+4, 2x6, 3x4 without TMA in first sectors and with TMA in last sector3x4 with TMA in first sectors and without TMA in last sector3x4 without TMA in first sector and with TMA in other sectors2x4|2x2 with and without TMA in first and third sector and optional TMA in other sectors2x4|2x2 with TMA in first sector, without TMA in third sector and optional TMA in other sectors2x4|2x2 without TMA in first sector, with TMA in third sector and optional TMA in other sectors

    o Dual band uncombined splitter configurations:2x4, 2x6, 2+4, 2+6, 2+2+4, 2+3+3, 2+4+2, 2+4+4, 3x4, 3+3+2, 3+3+4, 4+2, 4+6, 4+2+2, 4+2+4, 4+4+2, 4+3+3, 6+2, 6+4, 2x4|2x2|3x2 with and without TMA in all sectors independently4+6 without TMA in first sector and optional TMA in second sector4+6 with TMA in first sector and optional TMA in second sector

    o Dual band combined configuration with and without TMA in all sectors independently:2x2, 2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x2, 3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4, 2x2|2x2, 2x4|2x2, 3x2|3x2

    o Dual band combined splitter configuration with and without TMA in all sectors independently:2x4, 2x6, 2+4, 2+6, 2+8, 2+2+4, 2+4+2, 2+4+4, 3x4, 4+2, 4+6, 4+8, 4+2+2, 4+2+4, 4+4+2, 6+2, 6+4, 8+2, 8+4, 2x4|2x2

  • o Dual band configuration mix of combined and uncombined with and without TMA in all sectors independently:2+3+3, 3+3+2, 3+3+4, 4+3+3

    o Dual band splitter configuration mix of combined and uncombined with and without TMA in all sectors independently:2+3+3, 3+3+2, 3+3+4, 4+3+3

    RBS 2111 GSM1800.

    o Single band uncombined configurations:1x2, 2x2, and 3x2

    o Single band combined configurations:1x4 and 1x6

    o Dual band uncombined configurations:1x2 + 1x2, 1x2 + 2x2 and 2x2 + 1x2

    RBS 2206V2 Support (Same configurations as RBS 2206).

    1.2.38 Modified views

    Show Current Injectors in Radio View

    Filter Cables in Radio View

    Show Antenna System in Radio view as defined

    Show Cable info in Radio view

    Display OMT version and RBS type in System View

    Radio view:

    o Radio paths inside ASU/CXU/HCU/SPLITTER.

    o Tool tip on connection points with port names.

    1.2.39 New functions

    RF Cable Supervision in 2216 configurations

    Display RX/TX Antenna Mapping.

    OMT Improvements

    o Remain in same OMT view as defined

  • o R31_9

    1.3 R31_5

    1.3.1 New configurations

    RBS 2206, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900 with TMA single band 2 and 4-Way receiver diversity configurations.

    8+4 and 4+8 combined

    RBS 2x06, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900 with and without TMAs in all sectors independently.

    4+2 uncombined

    RBS 2216, GSM 900

    3x2 and 3x4 combined and uncombined

    RBS 2108, GSM 900.

    1x1, 2x1 and 3x1

    RBS 2111, GSM 900.

    1x4 and 1x6 combined

    1x2, 2x2 and 3x2 uncombined

    1.3.2 New functions

    Support for RBS 2108

    Support for RBS 2111

    Support for RBS 2216

    Monitor Report Header

    Display Faulty RUs

    Check IDB

    Improved description of define parameters

    ABIS optimizations

    ABIS over IP

  • 1.3.3 New views

    RBS 2108 cabinet and radio views

    RBS 2111 cabinet and radio views

    RBS 2216 cabinet and radio views

    1.3.4 New objects

    MU

    DRU_DRU_RXA, DRU_DRU_RXB, SPLITTER_DRU_RXA, SPLITTER_DRU_RXB, PSU_A

    1.3.5 New monitors

    New monitors added as part of ABIS Optimizations:

    Super Channel Quality

    Super Channel Configuration

    1.3.6 Modified functions:

    Create IDB:

    o Split of TX Combining and RX antenna sharing

    1.3.7 Modified views

    Radio view has been updated to show ASUs and EXTERNAL_CDU.

    Cabinet view for RBS 2206 has been updated with Splitter.

    R30_4

    1.3.8 New Configurations

    Mixed Micro RBSs

    1 RBS 2308 + 1 RBS 2302

    1 RBS 2308 + 2 RBS 2302

    2 RBS 2308 + 1 RBS 2302

  • 2 RBS 2308 + 2 RBS 2302

    1 RBS 2309 + 1 RBS 2302

    1 RBS 2309 + 2 RBS 2302

    2 RBS 2309 + 1 RBS 2302

    2 RBS 2309 + 2 RBS 2302

    RBS 2x06, CDU-G GSM 800, GSM 900, GSM 1800 and GSM 1900 with and without TMAs in all sectors independently.

    2+4, 3+3 uncombined.4+4 combined in first sector and uncombined in second sector. 4+4 uncombined in first sector and combined in second sector.

    RBS 2x06, CDU-G GSM 800 and GSM 900 with and without TMAs in all sectors independently.

    8+4 HCU in the first sector and combined in the second sector. 4+8 combined in the first sector and HCU in the second sector. 8+2 HCU in the first sector and combined or uncombined in the second sector. 2+8 combined or uncombined in the first sector and HCU in the second sector. 4+8, 8+4 with HCU and ASU. 1x8 with HCU.

    RBS 2206, CDU-G GSM 1800 and GSM 1900 with TMA single band 4-Way receiver diversity1[1] configurations:

    1x8, 1x12

    RBS 2106, CDU-G GSM 1800 and GSM 1900 with TMAsingle band 4-Way receiver diversity12 configurations:

    1x8, 1x12, 2x4, 2x6, 3x4

    1.3.9 New functions

    BSS R12 System Improvements, BTS

    Fault Filtering.

    Compress IDB.

    12

  • Compress SW Log.

    Increased Transmission Speed

    RBS 2000 Synchronization.

    Enable Bypass TMA on RBS 2101, RBS 2102 and RBS 2202.

    1.3.10 New monitors

    New monitors added as part of TG Synchronization Improvements

    ESB Measurement of ESB Delay active/inactive

    Measured ESB Delay

    Master transmitter chain delay

    Master transceiver group instance number

    ESB timeslot for measurements of ESB delay

    R29_3

    1.3.11 New Functions

    Support for RBS 2250

    Support for RBS 2106i

    1.3.12 New Configurations

    RBS 2250:

    o GSM 800 and GSM 1900 single band configurations:

    1x4, 1x8, 1x12

    RBS 2109:

    o GSM 900 and GSM 1800 single band configurations:

    1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2 and 1x6

    o Dual band configurations:

    1x2|1x2, 1x2|1x4 and 1x4|1x2

    RBS 2x07:

    o CDU J GSM 900 combined and uncombined (including mixed) single band configurations with TMA:

  • 1x4, 2+4 and 4+2.

    o CDU J GSM 800, GSM 1800 and GSM 1900 combined and uncombined (including mixed) single band configurations with and without TMA:

    1x4, 2+4 and 4+2.

    RBS 2107:

    o CDU J GSM 900 combined and uncombined (including mixed) single band configurations without TMA:

    1x4, 2+4 and 4+2

    1.3.13 New views

    RBS 2250 cabinet and radio views

    RBS 2106i cabinet and radio views

    R28_2

    1.3.14 New Configurations

    RBS 2106:GSM 800 | GSM 1900 and GSM 900 | GSM 1800 3 sector dual band configurations:3x2 | 3x2 combined, uncombined and mixed1+1+2 | 1+1+23x2 | 1+1+2 combined and uncombinedCDU F GSM 1900 single band configurations: 1x4, 1x8, 1x12, 2x6, 2x4, 3x4, 4+8 and 8+4

    Four Way Receiver Diversity configurations: 1x8, 1x12, 2x4, 2x6 and 3x4

    3+3+3 configurations.

    RBS 2206:CDU F GSM 1900 single band configurations: 1x4, 1x8, 1x12, 2x6, 2x4, 3x4, 4+8 and 8+4

    Four Way Receiver Diversity configurations: 1x8 and 1x12

    3+3+3 configurations.

    RBS 2112:GSM 900 single band configurations: 1x2 combined and uncombined

  • 1.3.15 Modified views

    Radio views have been updated to show TMA, Hybrid Combiner and HCU if available.

    1.3.16 New function

    Four Way Receiver Diversity in RBS 2106 and RBS 2206

    RBS 2309 P-GSM

    1.3.17 New views

    RBS 2112 cabinet and radio views

    1.3.18 New monitors for three sector dual band configurations:

    TMA Current on TMA_CM object.

    TMA Voltage on TMA_CM object.

    R26_5

    1.3.19 New configurations:

    RBS 2109:

    o Single band configurations GSM 800 and GSM 1900:

    1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2 and 1x6

    o Dual band configurations:

    1x2|1x2, 1x2|1x4 and 1x4|1x2

    RBS 2309:

    o Single band configurations GSM 900 and GSM1800:

    1x2, 2x1, 1x4, 2x2, 1+1+2, 2+1+1, 3x2, 2x3 2+4, 4+2 and 1x6

    o Dual band configurations:

    1x2|1x2, 1x2|1x4 and 1x4|1x2

    RBS 2107:

    o CDU J single band configurations:

  • 1+1, 1x2, 1+1+2, 2x2 and 3x2 uncombined

    1x2, 2x2 and 3x2 combined

    1+1+2, 2x2 and 3x2 uncombined/combined

    o CDU J dual band configurations:

    1x2|1x2, 1x2|2x2 and 2x2|1x2 uncombined, combined and uncombined/combined mixed.

    1.3.20 New views:

    RBS 2109, RBS 2309, RBS 2107 cabinet and radio views.

    1.3.21 New functions:

    RBS SW load indicator

    Extended RBS Holdover Time

    Simplified Software handling

    RBS name in IDB

    Battery event and stress log

    Support for Externally Powered TMAs

    1.3.22 Modified function:

    Display Software Information

    o Shows Filepackage name or Loadfile name

    RBS 2308

    o Possible to define more than one antenna system in a antenna sector.

    Information that is entered in the Create IDB function is not displayed in Display Information window for the RBS 2000 object any longer. This information can be found in Display Information window for the IDB object.

    R23_9

    1.3.23 New configurations:

    RBS 2207:

    o Mixed CDU J/G single band configurations:

  • 1+1, 1+1+2, 2x2 and 3x2 uncombined

    2x2 and 3x2 combined

    o CDU J single band configurations:

    1+1, 1x2, 1+1+2, 2x2 and 3x2 uncombined

    1x2, 2x2 and 3x2 combined

    1+1+2, 2x2 and 3x2 uncombined/combined

    o CDU J dual band configurations:

    1x2|1x2, 1x2|2x2 and 2x2|1x2 uncombined, combined and uncombined/combined mixed.

    R23_5

    1.3.24 Modified function:

    Define ALNA/TMA Parameters.

    R23_2

    1.3.25 New configurations:

    RBS 2x06:

    o Dual band 1x2|1x4

    o 2x3, 3+3+2, 3+3+4 combined

    o 4+8, 8+4 with ASU

    o 8+4, 4+8, 8+2, 2+8 HCU in one cell, uncombined/combined in other cell

    o 1x12, 1x8 with HCU

    o 4+8, 8+4 with HCU and ASU

    RBS 2207:

    o 1x2, 1+1, 2x2, 1+1+2, 3x2

    o 3x2, 2x2, 1x2 combined

    RBS 2308:

    o 1x4, 1x8, 1x12, 2x2, 2x4, 2x6, 3x4, 4+8, 8+4, 2+2+4, 4+2+2 900, 1800 duplex

    o 1x4, 1x12, 2x2, 2x4, 1x8, 3x4, 4+8, 8+4 1900 simplex

  • 1.3.26 New functions:

    OMT Wizard

    Define GPS Parameters

    1.3.27 New views:

    RBS 2207 cabinet and radio views

    1.3.28 New objects:

    ASU, ASU_CDU_RXA, ASU_CDU_RXB, ASU_CXU_RXA, ASU_CXU_RXB, CDU_ASU_RXA, CDU_ASU_RXB, CDU_HCU_TX, EXTERNAL_CDU, HCU

    1.3.29 New monitors:

    GPS position, GPS status, GPS satellites, GPS time - week, GPS time - seconds, GPS time - std dev.

    1.3.30 Modified views:

    Cabinet view:

    o Added ASU and HCU for RBS 2106 and RBS 2206

    1.3.31 Modified functions:

    OMT Wizard not supported on Win98, ME and NT.

    Fault status added on ASU for ASU_RXA units or cables and ASU_RXB units or cables Fault status added on ASU_CDU_RXA and ASU_CDU_RXB

    Monitor MO Fault maps, added Description, Action and Related faults

    Fault status added on DXU for GPS RX and GPS RX DXU

    R22_3

    1.3.32 New functions:

    Compare HW and IDB.

    Define Battery Backup Time Test Parameters.

    Display Battery Backup Time Test Parameters.

  • Display Battery Backup Time Test Result.

    Display Detected HW Information.

    1.3.33 Modified functions:

    Create IDB: Detected HW Information support.

    Define Battery Parameters: More parameters added.

    Install IDB: Detected HW Information support.

    R21_3

    1.3.34 New configurations:

    Support of double DXU EDGE.

    Mix of TMA/no TMA & combined/uncombined dTRUs in RBS 2106/2206.

    2x4, 3x4, 2x2 for RBS 2308, GSM 800.

    1x4, 2x4, 3x4, 2x2 for RBS 2308, GSM 1900, duplex.

    1x4 for RBS 2308.

    1.3.35 New monitors:

    TMA Current on TMA_CM object.

    TMA Voltage on TMA_CM object.

    1.3.36 Modified functions:

    Updated Load Flash Card description in OMT manual.

    Monitor: Monitor selection from Maintenance menu is simplified.

    o Monitors will be started by:

    1. Select a specific monitor.

    2. Select object to monitor.

    Monitor: Monitors previously available on both AO objects and SO objects are now only available on SO objects.

    Monitor: MO fault status changed to MO fault map, supporting extended fault reporting.

    Renamed Load DXU Flash Card to Load Flash Card

  • Display Status: Fault status on TIM.

    Display Cable List: Logical cable names added.

    1.3.37 New objects:

    IXU, RRU, TIM, RXBP, RRU_RXBP_RXA, RRU_RXBP_RXB.

    1.3.38 New views:

    RBS 2308 cabinet and radio views.

    1.3.39 New options:

    COM port number.

    R20

    1.3.40 New functions:

    Define Antenna Hopping.

    Define Battery Parameters.

    Define System Voltage.

    1.3.41 New monitors:

    Antenna hopping table list.

    1.3.42 Modified functions:

    Display/Import Site Specific Data (System Voltage and Battery Parameters added).

    1.3.43 New views:

    Object view.

    1.3.44 Other changes:

    OMT main window: New menus: RBS 2000, Edit, Configuration, Maintenance, Tools.

    Toolbar modifed: New icons for Connect/Disconnect.

    Not present RUs are selectable in all views.

  • MO view removed. MO objects available in Object view.

    Object menu replaced by Object view.

    Operation menu removed. Available by right mouse-click.

    R19_1

    1.3.45 New configurations:

    1x4, 1x6 for CDU-G, GSM 900/1800/1900

    Dual band 900/1900 for RBS 2202

    800 MHz for 2206 and 2106

    1.3.46 New objects:

    AODP-2, AODP-3.

    1.3.47 Modified functions:

    Define PCM: Now supporting 4 transmission ports.

    Display Status:

    o Fault status added on PCM for DP-2 and DP-3.

    Monitor:

    o Line attenuation and Phase difference Error for PCM C and PCM D added.

    1.3.48 Modified views:

    MO view : Added DP2 and DP3.

    1.3.49 New Remote OMT Hardware:

    Thor-2-PCI communication board also supported on Windows XP.

    R17_5

    -

    R17_4

  • 1.3.50 New configurations:

    RBS 2106, 2206.

    TMA selection per sector (2102, 2202, 2106 and 2206).

    1.3.51 New objects:

    OMT objects: DXU Flash Card.

    Active RUs: ACCU_02_DU, CCU_01, CXU, FCU, RBS_2106, RBS_2206, TMA_CM.

    Passive RUs: ACCU_02_CU, ACT_COOL_FAN, CDU_CDU_PFWD, CDU_CDU_PREF, CDU_CXU_RXA, CDU_CXU_RXB, CDU_TX_TX, CNU, CXU_TRU_RXA, CXU_TRU_RXB, TRU_TRU_TX1, TRU_TRU_TX2.

    1.3.52 New functions:

    Define Climate.

    Load DXU Flash Card.

    1.3.53 Modified functions:

    Define ALNA/TMA Parameters (TMA type added).

    Define VSWR Limits: Now also possible in Connected state.

    Display/Import Site Specific Data (Climate added).

    Display Status:

    o Fault status added: Battery temp sensor, IOM bus, CDU_CDU_PFWD, CDU_CDU_PREF, CDU_CXU_RXA, CDU_CXU_RXB, CXU_TRU_RXA, CXU_TRU_RXB, FCU, Flash card, HCOMB, TMA_CM, Y link, BFU fuse.

    o LED status added: Fault LED, Operational LED, Local Mode LED, Reduced Capacity LED, Battery fault LED, External alarm LED, RBS fault / BS fault LED, EPC bus fault LED, Transmission OK LED, Battery mode LED, DC disconnect LED, AC fault LED, FAN Fault LED, TMA OK LED, RF off /TX not enabled LED.

    Display SW Versions renamed to Display RBS SW Information.

    o If RBS SW is 8.1A or newer, the file package information is displayed else the load file names are displayed.

    Modify IDB renamed to Define Present RUs.

  • Define Present RUs (DC/DC Converter added).

    Monitor:

    o BDM Information, BFU Information and PSU Information added.

    Save RBS Log renamed to Display RBS Log, and opens a Notepad window.

    1.3.54 New views:

    2106, 2206 cabinet and radio views.

    1.3.55 Modified views:

    Hardware view -> Radio view.

    Radio view:

    o ECU and ENV objects removed.

    o PFWD and PREF connections displayed.

    1.3.56 New Remote OMT Hardware:

    Thor-2-PCI communication board supported on Windows 98/ME/NT/2000.

    R14_3

    1.3.57 New Remote OMT Hardware:

    THOR-2-PCI communication board.

    R14_1

    1.3.58 New functions:

    Display Paging Queue Status

    1.3.59 Modified functions :

    Connect R-OMT with selectable timeslot

    Display faulty RU and other monitors executes much faster

    Define TF Compensation only in local state

  • 1.4 R12

    1.4.1 New functions:

    Define PCM / Receiver Sensitivity A & B

    Define TF Compensation

    Define Delay

    1.4.2 Modified functions:

    Define PCM

    Import Site Specific Data

    1.4.3 New objects :

    ESB

    1.4.4 Modified Views:

    Hardware view shows faulty RU

    System view

    LimitationsIt is recommended to connect the OMT application to the RBS before running a wizard. The OMT might stop responding if a wizard is aborted during the connection phase.

    System software and hardware requirements

    2 System software requirementsEither of following operating systems:

    Microsoft Windows XP

    Microsoft Windows Vista

    Microsoft Windows 7

    The following additional software:

    Microsoft Internet Explorer 5.0 or higher

  • Microsoft Windows Installer 3.1 or higher. Windows Installer 3.1 will be automatically installed if not present on the target system, with a subsequent reboot required.

    Administrator rights on the computer are required to install the OMT program.

    Hardware requirements

    An IBM compatible PC with a processor that fulfils the operating system requirements. For good performance it's recommended to use a Pentium 4-compatible processor of at least 1 GHz.

    At least 50 Megabytes available hard disk space.

    At least 512 MB of RAM.

    Mouse (optional)

    A VGA graphic card.

    1 serial port and serial cable (To be able to connect an OMT PC with USB port to an RBS 2000 an USB-serial port adapter is needed).

    Installing the OMT softwareThe OMT is installed by executing the installation file: \OMT\Setup.exe, found on the OMT installation CD-ROM. All OMT software on the CD-ROM is then installed to a specified, or default (C:\Program Files\Ericsson AB\OMT_), directory on the hard disk.

    1. Insert the OMT installation CD-ROM into the CD-ROM drive.

    2. Run the OMT installation program by browsing to and double clicking the file \OMT\Setup.exe or by executing it from the Run... alternative in the Start menu.

    3. Follow the set-up instructions on the screen.

    The installation creates a new program group called OMT where the OMT icon can be found.

    The OMT can now be started either by double-clicking on the icon or by selecting the icon from the Start menu.

    To uninstall one version of the OMT

    1. Select Settings | Control Panel.

    2. Click on Add/Remove Programs.

    3. Select the OMT to be uninstalled and click on the Add/Remove button.

  • When upgrading from an earlier version of the OMT, the new version will be installed in another folder and a new icon will be added to the program group.

    1 Release Notes2 P49H(CXP 104 0015/6)1.1 New functions1.1.1 Modified functions1.1.2 New views1.1.1 Modified views1.1.3 New configurations1.1.4 New monitors1.1.5 R48S(CXP 104 0015/5)1.1.6 New functions1.1.7 Modified functions1.1.8 New views1.1.9 Modified views1.1.10 New configurations1.1.11 New monitors1.1.2 New functions1.1.3 Modified functions1.1.4 New views1.1.5 Modified views1.1.6 New configurations1.1.7 New monitors1.1.12 New function1.1.13 Modified function1.1.14 New configurations1.1.15 New monitors1.1.16 New views1.1.17 New function1.1.18 Modified function

    1.2 New Configurations1.2.1 New views1.2.2 New function1.2.3 New Configurations1.2.4 New views1.2.5 New Monitors1.2.6 New Configurations1.2.7 New views1.2.8 New function1.2.9 Modified function1.2.10 New monitors1.2.11 New Configurations1.2.12 New views1.2.13 New function1.2.14 Modified function1.2.15 New monitors1.2.16 New function1.2.17 New function1.2.18 Modified function1.2.19 New function1.2.20 Modified function1.2.21 New monitors1.2.22 Modified function1.2.23 New Configurations1.2.24 New views1.2.25 Modified views1.2.26 Modified functions1. Modified functions2. Modified views1.2.27 Modified functions1.2.28 New function1.2.29 Modified views1.2.30 New Configurations1.2.31 New function1.2.32 New monitors1.2.33 Modified functions1.2.34 New Configurations1.2.35 New functions1.2.36 New Configurations1.2.37 New Configurations1.2.38 Modified views1.2.39 New functions

    1.3 R31_51.3.1 New configurations1.3.2 New functions1.3.3 New views1.3.4 New objects1.3.5 New monitors1.3.6 Modified functions:1.3.7 Modified views1.3.8 New Configurations1.3.9 New functions1.3.10 New monitors1.3.11 New Functions1.3.12 New Configurations1.3.13 New views1.3.14 New Configurations1.3.15 Modified views1.3.16 New function1.3.17 New views1.3.18 New monitors for three sector dual band configurations:1.3.19 New configurations:1.3.20 New views:1.3.21 New functions:1.3.22 Modified function:1.3.23 New configurations:1.3.24 Modified function:1.3.25 New configurations:1.3.26 New functions:1.3.27 New views:1.3.28 New objects:1.3.29 New monitors:1.3.30 Modified views:1.3.31 Modified functions:1.3.32 New functions:1.3.33 Modified functions:1.3.34 New configurations:1.3.35 New monitors:1.3.36 Modified functions:1.3.37 New objects:1.3.38 New views:1.3.39 New options:1.3.40 New functions:1.3.41 New monitors:1.3.42 Modified functions:1.3.43 New views:1.3.44 Other changes:1.3.45 New configurations:1.3.46 New objects:1.3.47 Modified functions:1.3.48 Modified views:1.3.49 New Remote OMT Hardware:1.3.50 New configurations:1.3.51 New objects:1.3.52 New functions:1.3.53 Modified functions:1.3.54 New views:1.3.55 Modified views:1.3.56 New Remote OMT Hardware:1.3.57 New Remote OMT Hardware:1.3.58 New functions:1.3.59 Modified functions :

    1.4 R121.4.1 New functions:1.4.2 Modified functions:1.4.3 New objects :1.4.4 Modified Views:

    2 System software requirements