AIR CONDITIONING SYSTEM
Transcript of AIR CONDITIONING SYSTEM
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
COOLING ONLY [50Hz]AIR CONDITIONING SYSTEM
DIDSI2009
• SERVICE AND SPARE PARTS : Jakarta Selatan, Telp. : 021-2782 5545Cirebon, Telp. : 0231-880 2760 | Samarinda, Telp. : 0541-252 2889 | Banjarmasin, Tlp. : 0511-326 8168• TRAINING CENTER : Sunter, Telp. : 021-650 5028 • BRANCH : Bekasi, Telp. :021-2945 0585Tangerang, Telp. : 021-5314 1195 | Bandung, Telp. : 022-522 5150 | Semarang, Telp. : 024-7660 3221Yogyakarta, Telp. : 0274-551 321 | Surabaya, Telp. : 031-503 1138 | Denpasar, Telp. : 0361-900 5514Makassar, Telp. : 0411-805 2691 | Palembang, Telp. : 0711-573 2282 | Pekanbaru, Telp. : 0761-561 139Medan, Telp. : 061-4200 8866 | Manado, Telp. : 0341-719 1199
Specifications, designs and other content appearing in this brochure are current as of August 2020 but subject to change without notice.
21
Designed for use in cafe and restaurants, retail shops and small offices.
Daikin’s SkyAir series delivers superior comfort
and energy performance
for both occupants and building owners.
Cooling onlyCooling only
New Inverters launched
Previous non-inverter series R22 <cassette type>
New inverter RZFC-D series R32 <cassette type>
4.90 4.90
RZFC40DVM4Inverter
Non Inverter R18NUV1R35GV1 R30NUV1 / Y1R21NUV1 R26NUV1 / Y1 R36NUV1 / Y1 R42NUY1 R48NUY1
RZFC50DVM4
RZFC60DVM4
RZFC71DVM4 / Y14
RZFC85DVM4 / Y14
RZFC100DVM4 / Y14
RZFC125DY14
RZFC140DY14
CSPFValue
Comparison of cooling seasonal power consumptionbased on average CSPF values
Coo
ling
seas
onal
po
wer
con
sum
ptio
n
New inverter RZFC-D series(average)
Previous non-inverter series(average)
100
65
Note: Value 100 represents the amount of electricity used by a non-inverter model during a similar annual cooling period.
(cassette type)(cassette type)
4.674.10
4.674.29
2.63 2.79
4.67
2.77
5.13
2.69 2.79 2.732.71
6
5
4
3
2
1
0
CSPF values by capacity for cassette models
35%reduction!
What is CSPF?CSPF is the value for the annual total cooling load divided by the annual total power consumption at outdoor air conditions specified by ISO standard.
*CSPF (cooling seasonal performance factor) is a new international energy-efficiency criterion calculated by methods stipulated in ISO 16358-1.
3.10
Throughout the cooling season,Daikin’s new inverter models reduce energy consumptionCompared with previous non-inverter series, the new RZFC-D series uses about 35% less power consumption for quick and effective cooling that reduces electricity bills.
Energy Saving Tota
l cos
t =un
it pr
ice
+ c
ost o
f ele
ctric
ity
Time
InverterNon inverter
Roomtemperature
Time
Too hot
Set temperature
Smalltemperaturefluctuation
Too coldToo cold
Largetemperaturefluctuation
Comfortable
Non inverter
Non inverter
Inverter
Non inverter
Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in response to load fluctuations or load mismatch and causes large temperature swings.
Cap
acity
Load
0
Non inverter cooling capacity
Inverter cooling capacity
On/Off operation
Lower efficiency
Partial load area
Rated condition
Outdoor ambient temperature (°C)35
Cooling load
Continuous driving without stopping and starting is more fuel efficient.
Highway drivingInverterConstantly stopping and starting consumes energy and is less fuel efficient.
City drivingNon inverterStop, go, stop ...
Recovery point
Inverters save more energy over time
Inverter system consumes less electricity, and soon recovers the difference in initial cost. This results in lower total cost.
Inverter air conditioner can adjust its cooling capacity according to the cooling load. This results in less power consumption.
Inverters operate without repeated ON/OFF operation.
Why is inverter technology economical?Why is inverter technology economical?
Why is inverter technology more comfortable?Why is inverter technology more comfortable?
In response to fluctuating cooling load, Non inverter air conditioners repeatedly perform ON (full-power)/OFF (zero-power) operation. Inverter air conditioners, however, operate at optimal cooling capacity according to the cooling load. Since inverter air conditioners provide required minimum cooling capacity with minimum electrical power, total power consumption can be reduced during cooling period.
When temperature does not fluctuate much, the set temperature is maintained.
Inverter
Benefits of Inverter
43
Durability
100mm or
more
100mm or more 100mm or
more500mm or
more
Microchannel technology utilises superior heat transfer benefits of aluminium to create a more efficient air conditioner.With a new resistance corrosion aluminium alloy, the Daikin microchannel heat exchanger becomes highly durable.A salt spray test has been conducted to demonstrate the corrosion-resistant capability of our products in corrosive environments for a certain period of time.
After undergoing an intensive test, the Daikin microchannel heat exchanger is able to maintain its shape without corrosion, which strongly confirms its durability in a highly corrosive environment.
Microchannel heat exchanger
Outdoor unit installation is possible even with limited space
Test of durability- Testing organization - Testing standard- Result
MTEC ThailandASTM B117
Before testing After testing
Normalobservation
No evidence of corrosion was observed
Undertelescope
Coated circuit boards prevent problems caused by humidity and airborne dust.It also protects against salt contained in sea breezes.Both sides of the PCB in outdoor units are coated.
Coated printed circuit boards(outdoor unit)
In AM and PM peak electricity consumption periods, supply may fluctuate. Built-in low-voltage protection will automatically cut operations. When normal voltage is restored, operation will resume as before.
Automatic protection against low voltage
*FHFC40-85D requires optional adaptor to connect DIII-Net.
Possible to forced OFF and ON/OFF operation using external command
Indoor units (FCFC-D, FHFC100-140D, and FBFC-D) comply with D -Net standards
Design Flexibility
VRV
New indoor unit
Easy connection to DIII-NET and long piping length makes this solution suitable for projects including and SkyAir.
Adaptor notrequired
*Field setting with remote controller
Please see a video of the Micro Channel Heat Exchanger test in Pattaya.
QRspace
Interlock
Duct connection middle static pressure typeRound flow cassette type
Interlock
Lighting
65
Cooling only
Product Lineup
FCFC85DVM4
85 100 125 140
FCFC100DVM4 FCFC125DVM4 FCFC140DVM4
FHFC85DV14 FHFC100DV14 FHFC125DV14 FHFC140DV14
RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
1 phase, 220-240 / 220-230V,
50 / 60Hz
3 phase, 380-415V,
50Hz
1 phase, 220-240 / 220-230V,
50 / 60Hz
3 phase, 380-415V,
50Hz
3 phase, 380-415V,
50Hz
3 phase, 380-415V,
50Hz
RZFC85DVM4 RZFC85DY14
RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14RZFC85DVM4 RZFC85DY14
RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14RZFC85DVM4 RZFC85DY14
RZFC85DVM4 RZFC85DY14
RZFC85DVM4 RZFC85DY14
RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14RZFC85DVM4 RZFC85DY14
FDBF85DV14
FDLF85DV14
FBFC85DVM4 FBFC100DVM4 FBFC125DVM4 FBFC140DVM4
40
RZFC40DVM4
FCFC40DVM4
CEILING MOUNTED CASSETTE TYPE
Round Flow
CEILING SUSPENDED TYPE
Outdoor unit
Indoor unit
FHFC40DV14
Outdoor unit
Indoor unit
OUTDOOR UNIT
Power supply1 phase,
220-240 / 220-230V, 50 / 60Hz
1 phase, 220-240 / 220-230V,
50 / 60Hz
1 phase, 220-240 / 220-230V,
50 / 60Hz
1 phase, 220-240 / 220-230V,
50 / 60Hz
3 phase, 380-415V,
50Hz
Outdoor unit
50
RZFC50DVM4
FCFC50DVM4
FHFC50DV14
60
RZFC60DVM4
FCFC60DVM4
FHFC60DV14
71
FCFC71DVM4
FHFC71DV14
RZFC71DVM4 RZFC71DY14
RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14
RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Outdoor unit
Indoor unit
RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14
Outdoor unit
Indoor unit
RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14
Outdoor unit
Indoor unit
RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14
FDBF40DV14 FDBF50DV14 FDBF60DV14 FDBF71DV14
FDLF40DV14 FDLF50DV14 FDLF60DV14 FDLF71DV14
FBFC40DVM4 FBFC50DVM4 FBFC60DVM4 FBFC71DVM4
87
NEW
NEW
NEW
Power supply
SPECIFICATION (1 Phase)
Model Name
Indoor unit
Outdoor unit
Outdoor unit
40 50 60 71 85 100
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP kW/kWCSPF Wh/Wh
Certified Operation range
°CWBCertified Operation range
Motor outputCompressor
Coil
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R32) kg
dB(A) 48 49 50 51 52mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Unit
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Decoration panel
UnitDecoration panel
Airflow rate(H / M / L)
m3/mincfm
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Sound pressure level 3 Cooling
Sound pressure level 3 (H / M / L)
Indoor unit
Type
1 Phase, 220–240 / 220-230V, 50 / 60Hz
4.0(1.8-4.5)
5.0(2.3-5.6)
6.0(2.6-6.3)
7.1(3.2-8.0)
8.5(4.2-10.0)
10.0(5.0-11.2)
13,600(6,100-15,400)
1.26 1.57 1.89 2.38 2.85
38 / 34 / 2937 / 34 / 28 45 / 38 / 33
3.353.18 2.98
5.13 4.90 4.67
17,100(7,800-19,100)
20,500(8,900-21,500)
White
19 / 14 / 11671 / 494 / 388
37 / 32 / 28
19
23 / 18 / 13 34 / 27 / 20812 / 635 / 459 1,200 / 953 / 706
298X840X840
22 24
1.20 1.30 1.60
Fresh white
Ivory whiteMicro channel
Hermetically sealed swing type
256X840X84050X950X950
5.514 to 25
21 to 46
24,200(10,900-27,300)
29,000(14,300-34,100)
34,100(17,100-38,200)
FCFC40DVM4
RZFC40DVM4
FCFC50DVM4
RZFC50DVM4
FCFC60DVM4
RZFC60DVM4
FCFC71DVM4
RZFC71DVM4
FCFC85DVM4
RZFC85DVM4
FCFC100DVM4
RZFC100DVM4
Machine weight kg
kgUnitDecoration panel
0.7 (Charged for 10 m) 0.8 (Charged for 10 m)
595X845X300 695X930X350
1.0 (Charged for 15 m)
34 37 44
6.4 9.512.7 15.9
301530 (Equivalent length 40) 50 (Equivalent length 70)
VP20 (I.D. 20XO.D. 26)18.0 (Hole)
Both liquid and gas piping
Power consumption Cooling 1 kW
Sound pressure level 3 Cooling
WhiteFresh white
Ivory white
34 / 27 / 2023 / 18 / 13 36 / 29 / 211,200 / 953 / 706812 / 635 / 459 1,271 / 1,024 / 741
Micro channelHermetically sealed swing type
1.60 2.40
256X840X840 298X840X840
22 2450X950X950
5.514 to 25
21 to 46
SPECIFICATION (3 Phase)
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
125 1401008571
1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
695X930X350 990X940X320
46 62
9.515.9
30
50 (Equivalent length 70)
VP20 (I.D. 20XO.D. 26)18.0 (Hole) 26.0 (Hole)
Both liquid and gas piping
Power supply
Model Name
Indoor unit
Outdoor unit
Outdoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP kW/kWCSPF Wh/Wh
Certified Operation range
°CWBCertified Operation range
Motor outputCompressor
Coil
Dimensions(HXWXD)
Colour
mmmm
dB(A)
kWRefrigerant charge (R32) kg
dB(A) 50 51 52 54 56mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Unit
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Decoration panel
UnitDecoration panel
Airflow rate(H / M / L)
m3/mincfm
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Sound pressure level 3 (H / M/ L)
Indoor unit
Type
3 Phase, 380-415V, 50Hz
7.1(3.2-8.0)
24,200(10,900-27,300)
2.38 2.85 3.35 4.70 5.88
37 / 34 / 28 38 / 34 / 29 45 / 38 / 33 46 / 40 / 33
2.98 2.66 2.384.67 4.29 4.10
FCFC71DVM4
RZFC71DY14
8.5(4.2-10.0)
29,000(14,300-34,100)
FCFC85DVM4
RZFC85DY14
10.0(5.0-11.2)
34,100(17,100-38,200)
FCFC100DVM4
RZFC100DY14
12.5(5.7-14.0)
42,700(19,500-47,800)
FCFC125DVM4
RZFC125DY14
14.0(6.2-15.5)
47,800(21,200-52,900 )
FCFC140DVM4
RZFC140DY14
Machine weight kg
kgUnitDecoration panel
Power consumption Cooling 1 kW
CEILING MOUNTED CASSETTE TYPE Round Flow
FCFC40/50/60/71/85/100/125/140DVM4
Accessory required for indoor unit.
Option
BRC2E61
Simplified Remote Controller (Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
NEW
A signal receiver must be added to the indoor unit.
Wireless remote controller is supplied in a set with a signal receiver.
Wireless remote controller
Signal receiver unit (Installed type)
BRC7F635FCooling only
Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard
BYCQ125EAF
KDBH551C160
KDBH552C160
KDB55J160F
KDDP55B160 (KDDP55C160-1, KDDP55B160-2) 4
KDDP55B160K (KDDP55C160-1, KDDP55B160K2) 4
KDDP55X160A
KDDFP55C160
KAF5511D160
KAF555D160
KAF550D160
KAF556D160KAF556D80
KAF557D160KAF557D80
KAF552D160KAF552D80
KAF553D160
KDJP55C160
KAF553D80
KDJP55C80
KDTP55K160AKDTP55K80A
FCFC40DVM4FCFC50DVM4FCFC60DVM4
FCFC71DVM4FCFC85DVM4
FCFC100DVM4FCFC125DVM4FCFC140DVM4
Name of option Remark
Kit name
Option List
Fresh whiteDecoration panel
Panel spacer
Filter chamber
Replacement long-life filter
Ultra long-life filter unit (Including filter chamber)
Replacement ultra long-life filter 5
Branch duct chamber
Insulation kit for high humidity 612
11
10
9
8
6
2
4
5
1
7
3
Sealing material of air discharge outlet
Fresh air intake kit
For usage of 3-, 4-way flow
For usage of 2-way flow
High-efficiency filter unit(Including filter chamber)
(Colorimetric method 65%)
(Colorimetric method 90%)
Replacement high-efficiency filter 5(Colorimetric method 65%)
(Colorimetric method 90%)
Direct installation type 3
Without T-duct jointChambertype 1,2
With T-duct joint
Standard panel
Note: 1When installing a fresh air intake kit (chamber type), two air outlet corners are closed.2It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sensing.
3The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. The chamber type is recommended when more fresh air is necessary.
4Please order using the names of both components instead of set name.5Filter chamber is required.6Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.
No.
109
40 50 60 71 85 100
Sound pressure level 3 Cooling
SPECIFICATION (1 Phase)
Power supply
Model Name
Indoor unit
Outdoor unit
Outdoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP kW/kWCSPF Wh/Wh
Certified Operation range
°CWBCertified Operation range
Motor outputCompressor
Coil
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R32) kg
dB(A) 48 49 50 51 52mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Unit
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Unit
Airflow rate(H / M / L)
m3/mincfm
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Sound pressure level 3 (H / M / L)
Indoor unit
Type
1 Phase, 220–240 / 220-230V, 50 / 60Hz
4.0(1.8-4.5)
5.0(2.3-5.6)
6.0(2.6-6.3)
7.1(3.2-8.0)
8.5(4.2-10.0)
10.0(5.0-11.2)
13,600(6,100-15,400)
1.33 1.67 2.00 2.50 2.99 3.523.00 2.84
4.51 4.30 4.09
17,100(7,800-19,100)
20,500(8,900-21,500)
White13 / --- / 10 17 / --- / 14 24 / --- / 20 30 / --- / 25 28 / 24 / 20
459 / --- / 353 600 / --- / 494 847 / --- / 706 1,059 / --- / 883 988 / 847 / 70638 / --- / 33 39 / --- / 35
195X1,160X680 195X1,400X680 195X1,590X680 235X1,590X69042 / --- / 37 44 / --- / 39 42 / 38 / 34
1.20 1.30 1.60
Ivory whiteMicro channel
Hermetically sealed swing type
195X960X68027 32 35 3825
24,200(10,900-27,300)
29,000(14,300-34,100)
34,100(17,100-38,200)
FHFC40DV14
RZFC40DVM4
FHFC50DV14
RZFC50DVM4
FHFC60DV14
RZFC60DVM4
FHFC71DV14
RZFC71DVM4
FHFC85DV14
RZFC85DVM4
FHFC100DV14
RZFC100DVM4
Machine weight kgUnit
0.7 (Charged for 10 m) 0.8 (Charged for 10 m)
595X845X300 695X930X350
1.0 (Charged for 15 m)
34 37 44
6.4 9.512.7 15.9
301530 (Equivalent length 40) 50 (Equivalent length 70)
VP20 (I.D. 20XO.D. 26)18.0 (Hole)
Both liquid and gas piping
Power consumption Cooling 1 kW
21 to 46
14 to 25
Sound pressure level 3 Cooling
SPECIFICATION (3 Phase)
Power supply
Model Name
Indoor unit
Outdoor unit
Outdoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP kW/kWCSPF Wh/Wh
Certified Operation range
°CWBCertified Operation range
Motor outputCompressor
Coil
Dimensions (HXWXD)
Colour
mmdB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Unit
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Unit
Airflow rate(H / M / L)
m3/mincfm
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Sound pressure level 3 (H / M / L)
Indoor unit
Type
2.50 2.99 3.52 4.88 6.072.84 2.56 2.314.09 3.82 3.71
34 / 29 / 2431 / 27 / 2328 / 24 / 2030 / --- / 2524 / --- / 201,200 / 1,024 / 8471,094 / 953 / 812988 / 847 / 7061,059 / --- / 883847/ --- / 706
46 / 42 / 3844 / 41 / 3742 / 38/ 3444 / --- / 3942 / --- / 37
50 51 52 54 56
White
195X1,400X6803532 38
195X1,590X680 235X1,590X690
1.60 2.40
Ivory whiteMicro channel
Hermetically sealed swing type
Machine weight kgUnit
1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
46 62990X940X320695X930X350
9.515.9
3050 (Equivalent length 70)
VP20 (I.D. 20XO.D. 26)18.0 (Hole) 26.0 (Hole)
Both liquid and gas piping
Power consumption Cooling 1 kW
125 1401008571
3 Phase, 380-415V, 50Hz
7.1(3.2-8.0)
24,200(10,900-27,300)
FHFC71DV14
RZFC71DY14
8.5(4.2-10.0)
29,000(14,300-34,100)
FHFC85DV14
RZFC85DY14
10.0(5.0-11.2)
34,100(17,100-38,200)
FHFC100DV14
RZFC100DY14
12.5(5.7-14.0)
42,700(19,500-47,800)
FHFC125DV14
RZFC125DY14
14.0(6.2-15.5)
47,800(21,200-52,900 )
FHFC140DV14
RZFC140DY14
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
21 to 46
14 to 25
CEILING SUSPENDED TYPE
Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room
OptionAccessory required for indoor unit.
Option
BRC2E61
Simplified Remote Controller (Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
NEW
FHFC100/125/140DV14
FHFC40/50/60/71/85DV14
A signal receiver must be added to the indoor unit.
Wireless remote controller
Wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit (Installed type)
BRC7GA56Cooling onlyFHFC100-140D
Wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit (Installed type)
BRC7EA66Cooling onlyFHFC40-85D
Note: 1Wiring for wired remote controller should be obtained locally.2 This optional accessory requires DTA112BA51.3 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.4 Installation box for adaptor PCB (KRP1CA93, KRP1D93A) is necessary.
Kit name
Name of option Remark
Option List
No.
16
15
17
14
13
12
11
10
9
8
6
5
4
3
2
1
7
intelligent Touch Controller
Replacement long-life filter KAFJ501D56
BRC7EA66
--------
KAFJ501D112KAFJ501D80
KDU50N60VE KDU50N125VE
KHFP5M63 KHFP5M160
BRC2E61
BRP11B61
KRP4AA52
KJB311AA
KJB212AA
KAFJ501D160 KAF501B160
KDDQ50A140
KDU50R160
KHFP5N160
BRC7GA56
KRP1CA93 KRP1D93A
DTA112BA51 --------
BRCS01A-1 BRCS01A-4
DCS302CA61 2 DCS302CA61 3
DCS301BA61 2 DCS301BA61 3
DST301BA61 2 DST301BA61 3
DCS601C51 2 DCS601C51 3
Resin net
Wireless type
Wired type 1
L-type piping kit (for upward direction)
Remote controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Adaptor for wiring
Wiring adaptor for electrical appendices 4
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
Simplified remote controller
Drain pump kit
Fresh air intake kit
Interface adaptor for SkyAir series
Cooling only
FHFC100DV14FHFC125DV14FHFC140DV14
FHFC85DV14FHFC71DV14FHFC60DV14FHFC40DV14FHFC50DV14
1211
SPECIFICATION (1 Phase)
Model Name
Indoor unit
Outdoor unit
3.35 3.20 2.90 3.00 2.854.38 4.13 4.13 3.93 3.93
15 / 12 / 9.5 22.5 / 20 / 17.5530 / 424 / 335
37 / 33 / 25 39 / 35 / 33
794 / 706 / 618
245X700X800 245X1,000X80026
1.20 1.30 1.60
36
1.19 1.56 2.07
----------
----------
----------
1 Phase, 220-240V, 50Hz
2.37 2.98
40
FDBF40DV14
RZFC40DVM4
50
FDBF50DV14
RZFC50DVM4
60
FDBF60DV14
RZFC60DVM4
71
FDBF71DV14
RZFC71DVM4
85
FDBF85DV14
RZFC85DVM4
48 50 5149
34595X845X300 695X930X350
37 44
0.8 (Charged for 10 m) 1.0 (Charged for 15 m)0.7 (Charged for 10 m)
4.0(1.8-4.5)
5.0(2.3-5.6)
6.0(2.6-6.3)
7.1(3.2-8.0)
8.5(4.2-10.0)
13,600(6,100-15,400)
17,100(7,800-19,100)
20,500(8,900-21,500)
24,200(10,900-27,300)
29,000(14,300-34,100)
Ivory whiteMicro channel
Hermetically sealed swing type
21 to 46
14 to 25
Power supply Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP W/WCSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter 5
Rated 15 (15-38)
6.4 9.512.7 15.9
Both liquid and gas piping
30 (Equivalent length 40) 50 (Equivalent length 70)15 30
VP25 (I.D. 25XO.D. 32)18.0 (Hole)
----------
----------
----------
3 Phase, 380-415V, 50Hz
3.00 2.853.93 3.93
50 51
2.37 2.98
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3External static pressure is changeable in 11 stages by remote controller.4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.5Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.
SPECIFICATION (3 Phase)
Model Name
Indoor unit
Outdoor unit
71
FDBF71DV14
RZFC71DY14
85
FDBF85DV14
RZFC85DY14
2.401.0 (Charged for 15 m)
22.5 / 20 / 17.5794 / 706 / 618
245X1,000X800
39 / 35 / 33
36
7.1(3.2-8.0)
8.5(4.2-10.0)
24,200(10,900-27,300)
29,000(14,300-34,100)
14 to 25
695X930X35046
1.60
Ivory whiteMicro channel
Hermetically sealed swing type1.60
21 to 46
Power supply Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP W/WCSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter 5
Rated 15 (15-38)
9.515.9
Both liquid and gas piping
50 (Equivalent length 70)30
VP25 (I.D. 25XO.D. 32)18.0 (Hole)
Perfect for narrow entranceways
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
Perfect for narrow entranceways
FDBF40/50/60/71/85DV14
NEW
Accessory required for indoor unit.
BRC2E61
Simplified Remote Controller (Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
NEW
Option
Option List
FDBF40DV14FDBF50DV14FDBF60DV14
FDBF71DV14FDBF85DV14
Kit name
No. RemarkName of option
Remote controller
Wired type 1
BRC4C66
BRC2E61Simplified Remote Controller
Cooling
Note: 1Wiring for wired remote controller should be obtained locally.
2
1 Wireless type
BRCS01A-1Remote sensor (for indoor temperature)3
Mirror Pipe
Enables selection of right or left piping at installation site
For left side connection
For right side connection
Can select!
*New features for both FDBF and FDLF series.
BRC4C66
A signal receiver must be added to the indoor unit.
Cooling only
Wireless remote controller is supplied in a set with a signal receiver.
Wireless remote controller
Signal receiver unit (Separate type)
1413
----------1 Phase, 220-240V, 50Hz
3.35 3.20 2.90 3.00 2.854.33 4.13 4.13 3.93 3.93
1.19 1.56 2.07 2.37 2.98
SPECIFICATION (1 Phase)
Model Name
Indoor unit
Outdoor unit
40
FDLF40DV14
RZFC40DVM4
50
FDLF50DV14
RZFC50DVM4
60
FDLF60DV14
RZFC60DVM4
71
FDLF71DV14
RZFC71DVM4
85
FDLF85DV14
RZFC85DVM4
4.0(1.8-4.5)
5.0(2.3-5.6)
6.0(2.6-6.3)
7.1(3.2-8.0)
8.5(4.2-10.0)
13,600(6,100-15,400)
17,100(7,800-19,100)
20,500(8,900-21,500)
24,200(10,900-27,300)
29,000(14,300-34,100)
Power supply Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP W/WCSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter
16 / 14 / 12 20 / 18 / 16.5565 / 494 / 424 706 / 635 / 582
200X900X620 200X1,100X620
37 / 33 / 30 40 / 37 / 34
28 31
----------
Removable / Washable / Mildew proof
Rated 15 (15-38)
1.20 1.30 1.60
48 50 5149
34595X845X300 695X930X350
37 44
0.8 (Charged for 10 m) 1.0 (Charged for 15 m)0.7 (Charged for 10 m)
Ivory whiteMicro channel
Hermetically sealed swing type
21 to 46
14 to 25
6.4 9.512.7 15.9
Both liquid and gas piping
30 (Equivalent length 40) 50 (Equivalent length 70)15 30
VP25 (I.D. 25XO.D. 32)18.0 (Hole)
----------
----------
3 Phase, 380-415V, 50Hz
3.00 2.853.93 3.93
50 51
2.37 2.98
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3External static pressure is changeable in 11 stages by remote controller.4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
SPECIFICATION (3 Phase)
Model Name
Indoor unit
Outdoor unit
71
FDLF71DV14
RZFC71DY14
85
FDLF85DV14
RZFC85DY14
Removable / Washable / Mildew proof
20 / 18 / 16.5706 / 635 / 582
200X1,100X620
40 / 37 / 34
31
7.1(3.2-8.0)
8.5(4.2-10.0)
24,200(10,900-27,300)
29,000(14,300-34,100)
Power supply Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP W/WCSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter
Rated 15 (15-38)
2.401.0 (Charged for 15 m)
695X930X35046
1.60
Ivory whiteMicro channel
Hermetically sealed swing type1.60
21 to 46
14 to 25
9.515.9
Both liquid and gas piping
50 (Equivalent length 70)30
VP25 (I.D. 25XO.D. 32)18.0 (Hole)
Option ListKit name
No. RemarkName of option FDLF40DV14FDLF50DV14FDLF60DV14
FDLF71DV14FDLF85DV14
Remote controller
Wired type 1
BRC4C66
BRC2E61Simplified Remote Controller
Cooling
Note: 1Wiring for wired remote controller should be obtained locally.
2
1 Wireless type
BRCS01A-1Remote sensor (for indoor temperature)3
Enables high-ceiling design
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE
Enables high-ceiling design
FDLF40/50/60/71/85DV14
NEW
Accessory required for indoor unit.
BRC2E61
Simplified Remote Controller (Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
NEW
Option
BRC4C66
A signal receiver must be added to the indoor unit.
Cooling only
Wireless remote controller is supplied in a set with a signal receiver.
Wireless remote controller
Signal receiver unit (Separate type)
Easier and faster cleaning
Need to be removedby orderly
The integrated fan motorcan be removed andreinstalled in one time
Current New
Easy access to Control boxfrom bottom side
Need space area inside for maintenance Control box
All wiring and maintenance can be done from bottom side
Current New
*New features for both FDBF and FDLF series.Easy Maintenance
1615
SPECIFICATION (1 Phase)
Power supply
Model Name
Indoor unit
Outdoor unit
Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
4.0(1.8-4.5)
13,600(6,100-15,400)
5.0(2.3-5.6)
17,000(7,800-19,100)
6.0(2.6-6.3)
20,500(8,900-21,500)
7.1(3.2-8.0)
24,200(10,900-27,300)
8.5(4.2-10.0)
29,000(14,300-34,100)
10.0(5.0-11.2)
34,100(17,100-38,200)
COP W/W 3.35 3.20 2.90 3.00 3.10 3.15CSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit----------
----------
----------
1 Phase, 220–240 / 220-230V, 50 / 60Hz
----------3 Phase, 380-415V, 50Hz
40
FBFC40DVM4
RZFC40DVM4
50
FBFC50DVM4
RZFC50DVM4
60
FBFC60DVM4
RZFC60DVM4
71
FBFC71DVM4
RZFC71DVM4
85
FBFC85DVM4
RZFC85DVM4
100
FBFC100DVM4
RZFC100DVM4
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3External static pressure is changeable in 11 stages by remote controller.4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.5Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW 1.19
48 50 51 5249
1.56 2.07 2.37
1.30
2.74 3.17
4.38 4.18 4.18 3.983.98 3.98
547 / 424 / 318 883 / 706 / 582 1,271 / 1,077 / 883Rated 40 (40-140) Rated 50 (50-150)
15.5 / 12 / 9 25 / 20 / 16.5 36 / 30.5 / 25
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter 5
Power supply Indoor unit
Cooling Capacity 1,2
Rated (Min. - Max.) kW
Btu/h
COP W/WCSPF Wh/Wh
Certified Operation range
Sound pressure level 4
Motor outputCompressor
Coil
Colour
dB(A)
kWRefrigerant charge (R32) kg
dB(A)mmkg
°CDBmmmmmmmmmm
Dimensions (HXWXD)Machine weight
Piping connections
Liquid (Flare)Gas (Flare)
Drain Indoor unitOutdoor unit
Fan m3/mincfmPa
Outdoorunit
Colour
Heat insulation
Max. interunit piping lengthMax. installation level difference
Type
Cooling
Sound pressure level 4 (H/M/L)
Indoor unit
Type
Outdoor unit
Power consumption Cooling 1
Airflow rate (H/M/L)
External static pressure 3
kW
°CWBCertified Operation range
Dimensions (HXWXD) mm
Machine weight kg
Air filter 5
SPECIFICATION (3 Phase)
Model Name
Indoor unit
Outdoor unit
71
FBFC71DVM4
RZFC71DY14
85
FBFC85DVM4
RZFC85DY14
100
FBFC100DVM4
RZFC100DY14
125
FBFC125DVM4
RZFC125DY14
140
FBFC140DVM4
RZFC140DY14
Rated 30 (30-130)
34
2.37 2.74 3.17 5.21
2.40
6.22
50 51 52 54 5650
3.00 3.10 3.15 2.40 2.25
39 / 37 / 34 40 / 37.5 / 3537 / 35 / 30
245X1,000X800 245X1,400X800245X700X800
595X845X300 695X930X350
36 4626
1.60
37 44
1.200.8 (Charged for 10 m) 1.0 (Charged for 15 m)0.7 (Charged for 10 m)
Ivory whiteMicro channel
Hermetically sealed swing type
6.412.7
9.515.9
Both liquid and gas piping
30 (Equivalent length 40) 50 (Equivalent length 70)15 30
VP25 (I.D. 25XO.D. 32)18.0 (Hole)
14 to 25
21 to 46
7.1(3.2-8.0)
8.5(4.2-10.0)
10.0(5.0-11.2)
12.5(5.7-14.0)
14.0(6.2-15.5)
24,200(10,900-27,300)
29,000(14,300-34,100)
34,100(17,100-38,200)
42,700(19,500-47,800)
47,800(21,200-52,900)
----------
----------
3.983.98 3.98 3.71 3.60
883 / 706 / 582 1,271 / 1,077 / 883Rated 40 (40-140) Rated 50 (50-150)
25 / 20 / 16.5 36 / 30.5 / 25
39 / 37 / 34 40 / 37.5 / 35
245X1,000X800 245X1,400X800
695X930X350 990X940X32046 62
36 46
1.601.0 (Charged for 15 m) 1.35 (Charged for 15 m)
Ivory whiteMicro channel
Hermetically sealed swing type
9.515.9
Both liquid and gas piping
50 (Equivalent length 70)30
VP25 (I.D. 25XO.D. 32)18.0 (Hole) 26.0 (Hole)
14 to 25
21 to 46
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required.2Wiring for wired remote controller should be obtained locally. 3Mounting plate is necessary for each adaptor marked .
Option List
FBFC40DVM4FBFC50DVM4FBFC60DVM4
FBFC71DVM4FBFC85DVM4
FBFC100DVM4FBFC125DVM4FBFC140DVM4
High-efficiency filter 1
Filter chamber(for rear suction)1
Long-life filter 1
Air discharge adaptor
Adaptor for wiring 3
Wiring adaptor for electrical appendices(2) 3
Central remote controller 6
Unified ON/OFF controller 6
Schedule timer 6
intelligent Touch Controller 6
Service panel
Remote controller
65%
90%
Fresh white
Brown
Wired type 2
Kit name
KAF632C56 KAF632C80 KAF632C160
KAF633C56 KAF633C80 KAF633C160
KDDFP63B56 KDDFP63B80 KDDFP63B160
KDAP25A56A KDAP25A71A KDAP25A140A
KAF631C56 KAF631C80 KAF631C160
KTBJ25K56W KTBJ25K80W KTBJ25K160W
KTBJ25K56F KTBJ25K80F KTBJ25K160F
KTBJ25K56T KTBJ25K80T KTBJ25K160T
KDBD63A160
BRC4C66
BRC2E61
KRP4A98
BRCS01A-4
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
Shield plate for side plate
Simplified Remote Controller
Cooling
4Up to 2 adaptors can be fixed for each mounting plate.5Only one mounting plate can be installed for each indoor unit.6The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
BRP11B62
KRP4AA51
14
13
16
15
Drain pump kit BDU24AMD217
11
5
4
3
10
8
2
1
6
7
No. RemarkName of option
Remote sensor (for indoor temperature)9
Mounting plate for adaptor PCB.3,4,512
White
Wireless type
Middle static type allows greater flexibility
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
Middle static type allows greater flexibility
FBFC40/50/60/71/85/ 100/125/140DVM4
NEW
Accessory required for indoor unit.
BRC2E61
Simplified Remote Controller (Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
NEW
Option
BRC4C66
A signal receiver must be added to the indoor unit.
Cooling only
Wireless remote controller is supplied in a set with a signal receiver.
Wireless remote controller
Signal receiver unit (Separate type)
1817
4
3
2
1
Temperaturesetting (+/-)
BRC7F635FBRC7EA66BRC7GA56
BRC4C66
Cooling only
REMOTE CONTROLLER
All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use a stepladder to access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).
Enables temperature sensing closer to target area for improved comfort. (When using a remote control from another room, temperature-sensor of the indoor unit air inlet must be selected.)
Remote controller is equipped with error code display function. This facilitates service in the unlikely event of a malfunction.
SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations.
Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.
LCD panel shows operating status in letters, numbers, and motion.Airflow / swing display
Preset temperature / operation mode display
Programming time display
Self-diagnosis function
Displays auto-swing operating status and setting position of air discharge angle.
Displays preset room temperature and operating status (fan, dry, cool).
Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Optional accessory
BRC2E61NEW
Airflow rate (Fan speed)
Airflow direction
ON/OFF button
Operation mode selectionSimple operation
Using only six buttons, users have direct access to basic functions.This enables them to easily set comfort to their preference.
Intuitive designBy using pictograms, the user-friendly interface enables:
CompactMeasuring only 85 x 85 mm, the new remote controller is extremely compact and complements any interior design.
Overseas guests at hotels to understand functions without having to know a foreign language.
Children and elderly users at home to operate without having to read difficult and hard-to-see commands.
120 mm 120 mm
120 mm 85 mm
85 mm
70 mm
35mm
35mm
Conventional remote controller
Conventional simplifiedremote controllerBRC2E61
Reduced size
Signal receiver unit(Installed type)
BRC7F635F The wireless remote controller is supplied in a set with a signal receiver.Signal receiver unit of installed type is contained inside decoration panel or indoor unit.Shape of signal receiver unit differs according to the indoor unit.
Wired remote controller has built-in temperature-sensor
Facilitates maintenance and repair
CEILING MOUNTED CASSETTE TYPE
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPEDUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPEDUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
CEILING SUSPENDED TYPE40-85100-140
Wireless remote controller for each indoor unit type
BRC7GA56
Signal receiver unit(Installed type)
Signal receiver unit(Installed type)
BRC7EA66 BRC4C66
Signal receiver unit (Separate type)
Simplified Remote Controller (wired)
Wireless remote controller
OUTDOOR UNIT
Compact Outdoor Unit
Through use of a V-cut propeller fan that imitates the efficiency of the swan, a migratory bird, airflow becomes smooth and loss is reduced.
V-cut Propeller Fan
Technology for energy efficiency
3
2
1
4
Imitating the performance of the swan
(RZFC40-100DVM4/Y14)
RZFC40DVM4RZFC50DVM4RZFC60DVM4RZFC71DVM4
RZFC85DVM4RZFC100DVM4
RZFC71DY14RZFC85DY14RZFC100DY14
RZFC125DY14RZFC140DY14
*Although pumping-down operation allows most of the refrigerant to be recovered in a short period of time, some refrigerant will remain inside the indoor unit and refrigerant piping.Using a refrigerant recovery machine, recover remaining refrigerant from the stop valve service port until the pressure falls to 0.09 MPa. (gauge pressure:-0.011MPa) or less.
(Refrigerant recovery function)Facilitates pump down
*Pump-down function is available for pre-charged refrigerant amount.
Refrigerant cooling helps protect the printed circuit board and maintains high cooling capacity even during high outdoor temperatures.
(RZFC71-140DY14)
Conventional tube and fin coil Micro channel coil
High efficiency by micro channel heat exchangerHigh efficiency by micro channel heat exchanger
Daikin’s unique refrigerant cooling system exhibits high cooling capacity even during high outdoor temperatures.
Refrigerant coolingRefrigerant cooling
Utilizing flat, multi-hole heat exchanger tubes increases the heat exchange area and realizes energy savings.
Flow of refrigerant Flow of refrigerant
Flat, multi-hole aluminium heat exchanger tubes
Conventional heat exchanger
The diameter of the refrigerant channel(holes where refrigerant flows) is approx.1 mm.
The diameter of the refrigerant channel (holes where refrigerant flows) is approx. 7 mm
Approx. 1 mm
Approx. 7 mm
Reduced wind resistance
Micro channel heat exchanger
The flattening of the heat exchanger tubes improves the flow of air and increases heat exchange efficiency.
Energy savings is realised, eliminating the friction and the leakage of refrigerant gas.
Swing bushing Refrigerant gas
Piston by incorporated blade and roller.
Swing compressor High efficiency during partial load operation.
Fan
V-cut propeller fan
A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified.
Low gas pressure detection functionEffective gas monitoring reduces the labor required for operation, maintenance, and repairs.
Easy Installation and Maintenance
2019
REMOTE CONTROLLER Optional accessory
LCD REMOTE CONTROLLER
Central remote controller
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.
DCS302CA61 (Option)
With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.
DCS601C51 (Option)Unified on/off controller
Centralised control of on/off by group or all at once for up to 256 indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.
System variation to control multiple indoor units
(Command from outside)
Control by 1remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2remote controllers
Group control
Control by external command
Centralised remotecontrol
Interlock controlwith Heat Reclaim
Ventilator
(Basic system)
Link by remote controller group control.
Zone link control by centralised control.
For control from 2 locations such as in room and control room, exits, etc.
For simultaneous control of up to 16 indoor units.
Centralised control of up to 64 indoor groups from remote locationup to 1 km away.
Control by 1 wireless remote controller and 1 wired remotecontroller (See note 2)
Signal receiver unit installed on indoor unit
Signal receiver unit installed on indoor unit
Heat Reclaim Ventilator for indoor units within a zone is operated by interlocking.Can also be operated independently by remote controller.
Central remote controller (option)
Heat ReclaimVentilator
Can be operated simultaneously or independently by remote controller (set by ventilation mode)
Heat ReclaimVentilator
Central remote controller (option)
Non-polar, double-core (max. wiring length 500 m)
Connects 2 wired remote controllers (See note 1)
Automatic address setting function Automatic address setting function
Signal receiver unit installed on 1 indoor unit
Optional wiring adaptor for electrical appendices is necessary
Central remote controller (option)
Interface adapter for SkyAir series (option) is required (See note 3)
Interface adapter for SkyAir series (option) is required (See note 3)
Can be operated simultaneously by remote controller
Heat ReclaimVentilator
Heat Reclaim Ventilator for indoor units within a zone is operated by interlocking.
Central remote controller (option)
Heat ReclaimVentilator
Operation and monitoring is carried out using the contact signal from the operation control box in the monitoring room. Optional wiring adaptor for
electrical appendices is necessary
Interface adaptor for SkyAir series
DTA112BA51 (Option)Necessary for interface adaptor for SkyAir series with the central remote control units shown at above.
Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin system.
(Command from outside)
The interface adaptor for SkyAir series is required for Ceiling suspended type 40-85 class.
Note: 1BRC2E61 can connect to BRC2E61 only. 2When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers. Combination of BRC2E61 (main) and wireless remote controller (sub) is available. 3FHFC40-85D requires interface adaptor for SkyAir series.
*Except for FDBF and FDLF
Whatever your space, give it the comfort it deserves
*Except for FDBF and FDLF
*Except for FDBF and FDLF
2221
ON / OFF timer
Auto swing
Swing pattern selection
DC fan motor
Switchable fan speed
Auto airflow rate
Two selectable temperature-sensors
High ceiling application
FUNCTIONS
Cooling only
Functionsoverview
2
3
4
5
6
7
8
1
Drain pump mechanism
Pre-charged for up to 10 / 15 m *1
Long-life filter
Filter sign
Low gas pressure detection *1
Emergency operation
Self-diagnosis function
13
14
15
16
17
18
12
High-efficiency filter
Ultra long-life filter
Fresh air intake kit
28
29
27
Auto-restart
Control by 2 remote controllers
Group control by 1 remote controller
External signal forced OFF and ON/OFF operation
External command control *2
Central remote control
Interlock control with Heat Reclaim Ventilator
DIII-NET communication standard
20
21
22
23
24
25
26
19
Anti-bacterial air filter
Mould-proof air filter10
Silver ion anti-bacterial drain pan11
9
2
3
4
5
6
7
8
1
13
14
15
16
17
18
12
28
29
27
20
21
22
23
24
25
26
19
10
11
9
Indoor unit
Outdoor unit
Remotecontroller
BRC2E61
-------
-------
BRC7F635F
Wired
Wireless
Note:*1: For outdoor units. *2: Wiring adaptor for electrical appendices (and installation box) is necessary. *3: Option is requied. *4: For outdoor unit RZFC-DY14 only. *5: It is not possible to use 2 wireless remote controllers. Combination of BRC2E61 (main) and wireless remote controller (sub) is available.
3 step 3 step 2 step 2 step 3 step
3.5m / 4.2m 3.5m 4.3 m
3 step
-------
BRC7EA66
BRC2E61
-------
*3
*4*4 *4
*3
*5
*3
*3
*5 *5
FHFC100-140DV14
RZFC100DVM4RZFC100-140DY14
-------
BRC7GA56
BRC2E61
-------
CEILING SUSPENDED TYPECEILING MOUNTED
CASSETTE TYPE( Round Flow )
FHFC40-85DV14
RZFC40-85DVM4RZFC71/85DY14
FCFC40-140DVM4
RZFC40-100DVM4RZFC71-140DY14
3 step 3 step3 step 3 step 3 step 3 step
*3
*3
*3
*4
*5*5 *5
*4 *4
FBFC40-140DVM4
RZFC40-100DVM4RZFC71-140DY14
-------
BRC4C66
BRC2E61
-------
-------
BRC4C66
BRC2E61
-------
-------
BRC4C66
BRC2E61
-------
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
FDLF40-85DV14
RZFC40-85DVM4RZFC71/85DY14
FDBF40-85DV14
RZFC40-85DVM4RZFC71/85DY14
Cleanliness
Comfort
Work & Servicing
Control
Options
2423
Product Lineup
OUTDOOR UNIT
WALL MOUNTED TYPE
Outdoor unit
Indoor unit
FCQ60KAVE4FCQ50CKAVE4
25 60
CEILING MOUNTED CASSETTE TYPE
Round Flow
Series
CEILING SUSPENDED TYPE
Outdoor unit
Indoor unit
FLOOR STANDING TYPE
Outdoor unit
Indoor unit
DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE
Outdoor unit
Indoor unit
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
RZR50MVM4RZR50MVM4
FFQ25BV1B4
RKS25AVMG4
FHQ50DAVM4
RZR50MVM4
FHQ60DAVM4
RZR60MVM4
FHQ71DAVM4
RZR71MVM4
RZR50MVM4 RZR60MVM4 RZR71MVM4
RZR50MVM4 RZR60MVM4 RZR71MVM4
FHQ100DAVM4
RZR100MYM4
FAQ100CVEA4
RZR100MYM4
FHQ125DAVM4 FHQ140DAVM4
OUTDOOR UNIT
Outdoor unit
FCQ71KAVE4
RZR50MVM4
FCQ100KAVE4
RZR50MYM4
FCQ125KAVE4
RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14
RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14
RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14
FBQ125EVE4FBQ125EVE4FBQ71EVE4FBQ60EVE4FBQ50EVE4 FBQ140EVE4RZR125MYM4RZR100MYM4
RZR100MYM4
RZR125LUY14 RZR140MYM4 RZR140LUY14
FVQ125CVEB4FVQ100CVEB4FVQ71CVEB4FVQ60CVEB4FVQ50CVEB4 FVQ140CVEB4RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14
FCQ140KAVE4
FFQ35BV1B4
RKS35AVMG4
FFQ50BV1B4
RKS50AVMG4
FFQ60BV1B4
RKS60AVMG4
71 100 125 14035
Outdoor unit
50
RKS25AVMG4 RKS35AVMG4 RKS50AVMG4 RKS60AVMG4
2625
SPECIFICATION (3 Phase)
Cooling capacity1,2
Rated (Min. - Max.) kW
Btu/h
ModelName
Indoor unit
Outdoor unit
Outdoor unitPower supply 1 Phase, 220–240 V, 50 Hz
kWPower consumption Cooling1
°CWBCertified Operation range
Dimensions(HXWXD) mm
mmdB(A)
Unit
Decoration panelMachine weight kg
kgUnitDecoration panel
Airflow rate (H/M/L) m3/mincfm
Sound pressure level 3 (H/M/L)
Indoorunit
256X840X840 298X840X840 256X840X840298X840X84050X950X950
5.5
14 to 25
44/39/34 44/40/36 44/39/34 44/40/36
33/28/22.5 21/17.5/13.5 33/28/22.5 21/17.5/13.51,165/988/794 741/618/477 1,165/988/794 741/618/477
35/31.5/28 35/31.5/28
24 21 24 21
W/WCOP
125
FCQ125KAVE4
RZR125LVVM4
12.5 (5.7-14.0)
140
FCQ140KAVE4
RZR140LVVM4
14.0 (6.2-15.4)
3.68 4.913.40 2.85
125
FCQ60KAVE4x2
RZR125LUY14
12.5 (5.7-14.0)
140
FCQ71KAVE4x2
RZR140LUY14
14.0 (6.2-15.4)
3.68 4.913.40 2.85
125
FCQ60KAVE4x2
RZR125LVVM4
12.5 (5.7-14.0)
140
FCQ71KAVE4x2
RZR140LVVM4
14.0 (6.2-15.4)
3.68 4.913.40 2.85
3 Phase, 380–415 V, 50 Hz
125
FCQ125KAVE4
RZR125LUY14
12.5 (5.7-14.0)
140
FCQ140KAVE4
RZR140LUY14
14.0 (6.2-15.4)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
3.68 4.913.40 2.85
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
dB(A)
°CDBCertified Operation range
Sound pressurelevel3
Motor outputCompressor
Coil
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
Type
Cooling
Ø9.5Ø15.9
50
1,170X900X32097
3050 (Equivalent length 70)
Hermetically sealed scroll typeType Cross fin coil
Ø26.0 (Hole)VP25 (I.DØ25XO.DØ32)
21 to 46
Night quiet mode
3.15 (Charged for 30 m)2.4 3.1
45 46
2.4 3.1
45 46
2.4 3.1
45 46
3.7 (Charged for 30 m)2.4 3.1
45 46
intelligent Touch Controller4
Note: 1Refer to page 20 for the details. 2Required for installing high-efficiency filter unit and ultra long-life filter unit. 3Wiring for wired remote controller to be procured locally.4The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5Installation box for adaptor PCB (KRP1H98) is necessary.
Option ListKit name
KDJP55B160KDJP55B80
KAFP556B80KAFP557B80KAFP552B80KAFP553B80
KAFP556B160KAFP557B160KAFP552B160KAFP553B160
FCQ71KAVE4 FCQ100KAVE4FCQ50KAVE4 FCQ60KAVE4 FCQ125KAVE4 FCQ140KAVE4Name of option Remark
Chamber type
Decoration panel
Fresh air intake kit1
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Adaptor for wiring5
Without T-duct jointWith T-duct joint
Direct installation type
Sealing material of air discharge outletPanel spacer
Wiring adaptor for electrical appendices(2)5
Installation box for adaptor PCB
High-efficiency filter unit (including filter chamber)
(Colorimetric method 65%)(Colorimetric method 90%)
Replacement high-efficiency filter
(Colorimetric method 65%)(Colorimetric method 90%)
Remote controller Wireless type Cooling only
Wired type3 Wired type3
Branch duct chamber
Remote sensor (for indoor temperature)
DCS601C51
DCS302CA61DCS301BA61DST301BA61
KRP1C63
KDBH55K160FKDBP55H160FA
KDDP55B160KDDP55B160KKDDP55X160
KRP4AA53
BRC7F635F
BYCP125K-W1
KRP1H98KRCS01-4B
BRC1E62BRC1C61
KDDFP55B160Filter chamber
Navigation Remote Controller
KDTP55K160Chamber connection kit2
Insulation kit for high humidityKKSJ55KA160
KDTP55K80
KAFP551K160KAFP55B160
KAFP55H160H
Replacement long-life filterUltra long-life filter unit (including filter chamber)Replacement ultra long-life filter
FCQ50/6071/100/125/140KA
CEILING MOUNTED CASSETTE TYPE Round Flow
Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard
Accessory required for indoor unit.
BRC1C61
Wired LCD Remote Controller
Note: Remote controller cable is not included and must be obtained locally.
A signal receiver must be added to the indoor unit. Wireless LCD remote controller
Signal receiver unit (Installed type)
Wireless remote controller is suppliedin a set with a signal receiver.
BRC7F635FBRC1E63
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
SPECIFICATION (1 Phase)
Cooling capacity1,2
Rated (Min. - Max.) kW
Btu/h
ModelName
Indoor unit
Outdoor unit
Power supply
71
FCQ71KAVE4
RZR71MVM4
7.1 (3.2-8.0)
100
FCQ100KAVE4
RZR100MVM4
10.0 (5.0-11.2)
125
FCQ125KAVE4
RZR125MVM4
1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz12.5
(5.7-14.0)
140
FCQ140KAVE4
RZR140MVM4
14.0 (6.2-15.4)
kWPower consumption Cooling1
100
FCQ100KAVE4
RZR100MYM4
10.0 (5.0-11.2)
125
FCQ125KAVE4
RZR125MYM4
12.5 (5.7-14.0)
140
FCQ140KAVE4
RZR140MYM4
14.0 (6.2-15.4)
1.99 2.78 4.31 5.62 2.78 4.31 5.62
50
FCQ50KAVE4
RZR50MVM4
5.0 (2.3-5.6)
60
FCQ60KAVE4
RZR60MVM4
°CWBCertified Operation range
Dimensions(HXWXD) mm
mmdB(A)
Unit
Decoration panelMachine weight kg
kgUnitDecoration panel
Airflow rate (H/M/L) m3/mincfm
Sound pressure level 3 (H/M/L)
Indoorunit
43/37.5/32
32/26/20
44/39/34
24
298X840X84050X950X950
5.5
33/28/22.51,130/918/706 1,165/988/794
44/40/36
14 to 25
43/37.5/32
32/26/20
44/39/34
33/28/22.51,130/918/706 1,165/988/794
44/40/3635/31.5/28
21
256X840X840
21/17.5/13.5741/618/477
6.0 (2.6-6.3)
24,200(10,900-27,300)
34,100(17,100-38,200)
42,700(19,500-47,800)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
47,800(21,200-52,600)
17,100 (7,900-19,100)
20,500(8,900-21,500)
1.24 1.58W/WCOP 3.57 3.60 2.90 2.49 3.60 2.90 2.494.03 3.80
dB(A)
°CDBCertified Operation range
Sound pressurelevel3
Motor outputCompressor
Coil
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
Type
Cooling
Hermetically sealed swing typeType Cross fin coil Micro channel
1.76
49
990X940X32065
2.031.9(Charged for 30 m)
Ø9.5Ø15.9
52 54 52 54
3050 (Equivalent length 70)
Ø26.0 (Hole)VP25 (I.DØ25XO.DØ32)
21 to 4673
1.92
49Night quiet mode
1.12
48
595X845X30043
1.351.6(Charged for 30 m)
4544
Outdoor unit
36O° AIRFLOW
GENTLE AIR MOVEMENT WITH ROUND FLOW
SILVER ION ANTI-BACTERIAL DRAIN PAN
ANTI-MOULD & ANTI-BACTERIAL TREATMENTFILTER
SUITABLE FOR HIGH CEILINGS
QUICK & EASY TO INSTALL
FEATURES
27 28
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE25 35
1 Phase, 220–240 V, 50 Hz2.5
(1.2-3.0)3.4
(1.2-3.7)
0.73 1.103.42 3.09
4.7 (1.7-5.6)
5.8 (1.7-6.0)
8,500(4,100-10,250)
11,600(4,100-12,600)
16,000(5,800-19,100)
19,800(5,800-20,500)
1.62 2.072.90 2.80
FFQ25BV1B4
RKS25AVMG4
FFQ35BV1B4
RKS35AVMG4
50 60
FFQ50BV1B4
RKS50AVMG4
FFQ60BV1B4
RKS60AVMG4
kWPower consumption
ModelName
Indoor unit
Outdoor unit
cfm
286X575X57555X700X700
2.717.5
29.5/24.5 32/25
14 to 23°CWBCertified operation range
Indoorunit
Dimensions(HXWXD) mm
mmSound pressure level2 (H/L) dB(A)
UnitDecoration panel
Machine weightkgkgUnit
Decoration panel
Airflow rate (H/L) 9/6.5 10/6.5317/229 353/229
36/27 41/32
12/8 15/10423/282 529/353
m3/min
Power supply
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
VP20 (I.DØ20XO.DØ26)
10 to 46
46 47 49550X765X285
34735X825X300
47
1.00.6
Ø6.4o/ 9.5 o/ 12.7
2015
3020
Hermetically sealed swing type
Ø18.0 (Hole)
(Charged for 10 m)1.51.1
(Charged for 10 m)
Sound pressure level2
°CDBCertified operation range
Motor outputCompressor
kWRefrigerant charge (R-410A)
dB(A)Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
kg
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
TypeCross fin coilCoil Type
kW
Btu/h
Cooling capacity1
Rated (Min. - Max.)
Cooling1
W/WCOP
Outdoor unit
BRC7E531W
Kit nameName of option Remark
intelligent Touch Controller3
FFQ25BV1B4 FFQ35BV1B4 FFQ50BV1B4 FFQ60BV1B4Decoration panel
Fresh air intake kit
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Adaptor for wiring2
Direct installation type
Wiring adaptor for electrical appendices2
Sealing material of air discharge outletPanel spacer
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Replacement long-life filter
Remote sensor (for indoor temperature)
DCS302CA61DCS301BA61
DCS601C51DST301BA61
KRP1BA57KRP4AA53KRCS01-1B
BYFQ60B3W1
BRC1C61
KDBH44BA60KDBQ44BA60A
KDDQ44XA60
DTA112BA51
KRP1BA101
KAFQ441BA60
Note: 1Wiring for wired remote controller to be procured locally.2Installation box for adaptor PCB (KRP1BA101) is necessary. 3This optional accessory requires DTA112BA51.
Option List
Remote controller Wireless type Cooling only
BRC1E62Navigation Remote Controller Wired type1
Wired type1
FFQ25/35/50/60B
COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE
Quiet decor-blending form and easyinstallation in new or old buildingQuiet decor-blending form and easyinstallation in new or old building
Accessory required for indoor unit.
BRC1C61
Wired LCD Remote Controller
Note: Remote controller cable is not included and must be obtained locally.
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
Signal receiver unit (Installed type)
Wireless remote controller is suppliedin a set with a signal receiver.
BRC7E531W
SIZED TO FIT INSIDE 600mm WIDE CEILING GRIDS
MULTI-FLOW SYSTEM
QUIET, SMALL-DIAMETER FAN
AIR DIRECTION CAN BE SELECTEDACCORDING TO INSTALLATION
CONSISTENT COMFORT THROUGHOUT
TWO SELECTABLE TEMPERATURE-SENSORS
FEATURES
BRC1E63
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
3029
intelligent Touch Controller2
Kit nameName of option
FHQ50DAVM4 FHQ60DAVM4
DCS302CA61DCS301BA61DST301BA61
KAFP501A56
Remark
Replacement long-life filter
L-type piping kit (for upward direction)Remote controller
Resin net
Wireless type
Central remote controllerUnified ON/OFF controllerSchedule timer
Wiring adaptor for electrical appendicesWiring adaptor for electrical appendices3
Installation box for adaptor PCB
Option List
Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB(KRP1D93A) is necessary.
Cooling only
FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4
KRP1BA54DCS601C51
KRP4AA52
KAFP501A80 KAFP501A160
KJB311AAKJB212AA
Remote sensor (for indoor temperature)Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
BRC1C61BRC1E62Navigation Remote Controller Wired type1
Wired type1
Drain pump kitFresh air intake kit
KDU50P140VEKDDQ50A140
BRC7GA56
KRP1D93AAdaptor box mounting plate KKSAP50A56
KHFP5N160
KRCS01-4B----------
SPECIFICATION (3 Phase)
kW
Btu/h
kWPower consumption
ModelName
Indoor unit
Outdoor unit
Outdoor unitPower supplyCooling capacity1,2
Rated (Min. - Max.)
140
FHQ140DAVM4
RZR140LUY14
13.3(6.2-15.4)
125
FHQ125DAVM4
RZR125LUY14
12.5(5.7-14.0)
W/WCOP 2.843.12
1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
140
FHQ140DAVM4
RZR140LVVM4
13.3(6.2-15.4)
2.52
125
FHQ125DAVM4
RZR125LVVM4
12.5(5.7-14.0)
2.83 2.522.83 2.522.83 2.522.832.843.12
140
FHQ71DAVM4x2
RZR140LUY14
13.3(6.2-15.4)
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
VP20 (I.DØ20XO.DØ26)
30
Ø9.5Ø15.9
Ø26.0 (Hole)
°CDBCertified operation range
Motor output
CoolingNight quiet mode
CompressorCoil
kWRefrigerant charge (R-410A) kg
dB(A)dB(A)
Sound pressure level3
Dimensions (HXWXD) mm
Machine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
Type Hermetically sealed scroll typeType Cross fin coil
2.9
45 4645 46
21 to 46
1,170X900X32097
50
2.6
3.7(Charged for 30 m)
3.12.4
3.15 (Charged for 30 m)
50 (Equivalent length 70)
2.9
45 4645 46
2.4 3.12.4 3.1 2.4 3.12.4 3.1
125
FHQ60DAVM4x2
RZR125LUY14
12.5(5.7-14.0)
2.843.12
140
FHQ71DAVM4x2
RZR140LVVM4
13.3(6.2-15.4)
125
FHQ60DAVM4x2
RZR125LVVM4
12.5(5.7-14.0)
2.843.124.684.004.684.00 4.684.004.684.00
°CWBCertified operation range
Dimensions (HXWXD) mmdB(A)
Machine weight kg
Airflow rate (H/M/L) m3/min
Sound pressure level3 (H/M/L)
Indoorunit cfm
14 to 25
31/27/231,094/953/812 1,200/1,024/847
44/41/37 46/42/38 44/41/37 46/42/381,094/953/812 1,200/1,024/847
34/29/24 31/27/23 34/29/24
235X1590X69038
235X1590X69038
20.5/17/1415/12/10724/600/494530/424/353
38/36/3437/35/32235X1,270X690235X960X690
3225
20.5/17/1415/12/10724/600/494530/424/353
38/36/3437/35/32235X1,270X690235X960X690
3225
Cooling1
45,000(21,200-52,600)
42,700(19,500-47,800)
45,000(21,200-52,600)
42,700(19,500-47,800)
45,000(21,200-52,600)
42,700(19,500-47,800)
45,000(21,200-52,600)
42,700(19,500-47,800)
FHQ50/60/71/100/125/140DA
CEILING SUSPENDED TYPE
Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room
100
FHQ100DAVM4
RZR100MVM4
10.0 (5.0-11.2)
3.03
60
FHQ60DAVM4
RZR60MVM4
6.0 (2.6-6.3)
1.58
SPECIFICATION (1 Phase)
3 Phase, 380–415 V, 50 Hz
kW
Btu/h
kWPower consumption
ModelName
Indoor unit
Outdoor unit
Power supplyCooling capacity1,2
Rated (Min. - Max.)
125100
FHQ100DAVM4 FHQ125DAVM4
RZR100MYM4 RZR125MYM4
140
FHQ140DAVM4
RZR140MYM4
10.0 (5.0-11.2)
12.5 (5.7-14.0)
50
FHQ50DAVM4
RZR50MVM4
5.0(2.3-5.6)
1.24 3.03 4.42
125
FHQ125DAVM4
RZR125MVM4
12.5 (5.7-14.0)
4.42
1 Phase, 220–240 V, 50 Hz
71
FHQ71DAVM4
RZR71MVM4
2.373.303.80W/WCOP 4.03 3.30 2.83
VP20 (I.DØ20XO.DØ26)
Hermetically sealed swing type
30
Ø9.5Ø15.9
990X940X32065
49
Ø26.0 (Hole)
2.031.9(Charged for 30 m)
595X845X30043
48
1.351.6 (Charged for 30 m)
°CDBCertified operation range
Motor output
CoolingNight quiet mode
CompressorCoil
kWRefrigerant charge (R-410A) kg
dB(A)dB(A)
Sound pressure level3
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
TypeCross fin coil Micro channelType
73
49 52
1.92
4544
1.12
21 to 46
50 (Equivalent length 70)
1.76
5452 54
14.0(6.2-15.4)
5.552.522.833.00
7.1 (3.2-8.0)
20,500(8,900-21,500)
17,100(7,900-19,100)
24,200(10,900-27,300)
Cooling1
Outdoor unit
140
FHQ140DAVM4
RZR140MVM4
42/38/34235X1,590X690235X1,270X690
3832
28/24/2020.5/17/14988/847/706
38/36/34724/600/494
37/35/32235X960X690
25
15/12/10530/424/353
°CWBCertified operation range
Dimensions (HXWXD) mmdB(A)
Machine weight kg
Airflow rate (H/M/L) m3/min
Sound pressure level3 (H/M/L)
Indoorunit cfm
42/38/3446/42/38 44/41/37
28/24/20 31/27/23988/847/706 1,094/953/812
14 to 25
44/41/37
31/27/231,094/953/812
46/42/38
34/29/241,200/1,024/847
34/29/241,200/1,024/847
14.0(6.2-15.4)
34,100(17,100-38,200)
34,100(17,100-38,200)
42,700(19,500-47,800)
42,700(19,500-47,800)
47,800(21,200-52,600)
47,800(21,200-52,600)
5.552.52
Accessory required for indoor unit.
BRC1C61
Wired LCD Remote Controller
Note: Remote controller cable is not included and must be obtained locally.
A signal receiver must be added to the indoor unit. Wireless LCD remote controller
BRC7GA56
Wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit (Installed type)
BRC1E63
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
SOPHISCATED DESIGN
FLEXIBLE INSTALLATION
AUTO SWING & LOUVERS
NON FLOCKING FLAP
SUITABLE FOR HIGH CEILINGS
QUIET OPERATION
FEATURES
3231
Cooling capacity1,2
Rated (Min. - Max.) kW
Btu/h
kWPower consumption
ModelName
Indoor unit
Power supply
Cooling1
SPECIFICATION (1 Phase, 3 Phase)100
FAQ100CVEA4
RZR100MVM4
100
FAQ100CVEA4
RZR100MYM4
10.0(5.0-11.2)
34,100(17,100-38,200)
°CWBCertified Operation range
Dimensions (HXWXD) mmdB(A)
Machine weight kg
Airflow rate (H/M/L)
Sound pressure level3 (H/M/L)
Indoorunit
m3/min
49/45/41
17340X1,200X240
26/23/19
14 to 25
cfm 918/812/671
3.37
W/WCOP 2.97
1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Outdoor unit
Outdoor unit
°CDBCertified Operation range
Sound pressure level 3
Motor outputCompressor
Coil
kWRefrigerant charge (R-410A) kg
dB(A)
Dimensions (HXWXD) mm
Machine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Outdoor unit
Outdoorunit
mmMax. interunit piping length m
mMax. installation level difference
Type
Cooling
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
Ø9.5
49dB(A)Night quiet mode 45
30
Ø15.9
Hermetically sealed swing typeType Micro channel
Ø26.0 (Hole)
1.9 (Charged for 30 m)
21 to 46
50 (Equivalent length 70m)
990X940X32065 73
2.03 1.92
VP13 (O.DØ18 X I.DØ13)
BRC1C61
intelligent Touch Controller2
Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA93) is necessary.
Option ListName of option Remark
Central remote controller2
Remote controller
Unified ON/OFF controller2
Schedule timer2
Wiring adaptor for electrical appendices3
Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)
Kit nameFAQ100CVEA4
DCS302CA61DCS301BA61DST301BA61DCS601C51KRP4AA51
KJB311AAKJB212AA
Drain-up kit
Installation box for adaptor PCB
Noise filter ( For electromagnetic interface use only)
Remote sensor (for Indoor temperature) KRCS01-4B
K-KDU572EVE
KRP4AA93
KEK26-1A
BRC7EB519Wireless type
BRC1E62Navigation Remote Controller Wired type1
Wired type1
Cooling only
WALL MOUNTED TYPE
Compact designand easy installationCompact designand easy installation
FAQ100C
Accessory required for indoor unit.
BRC1E63
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
BRC1C61
Wired LCD Remote Controller
Note: Remote controller cable is not included and must be obtained locally.
A signal receiver must be added to the indoor unit.
Wireless LCD remote controller
BRC7EB519
Wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit (Installed type)
COMPACT & SOPHISCATED DESIGN
6-DIRECTION REFRIGERANT PIPING FLEXIBILITY
AUTO SWING & WIDE-ANGEL LOUVERS
INTERLOCK CONTROL
COMFORT EVEN ON THE FAR SIDE OF THE ROOM
EASY CLEANING
FEATURES
3433
Power supply 1 Phase, 220–240 V, 50 Hz1 Phase, 220–240 V, 50 Hz
SPECIFICATION (1 Phase)
ModelName
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
kW
Btu/h
°CDB
°CWB
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressorCoil
Indoorunit
Dimensions (HXWXD)Air filter5
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)Sound pressure level4
Sound pressure level4 (H/M/L)
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate (H/M/L)Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCooling1Power consumption
Pa
cfm
Night quiet mode dB(A)
External static pressure3
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50
FBQ50EVE4
RZR50MVM4
5.0 (2.3-5.6)
50 (Equivalent length 70)
VP25 (I.DØ25XO.DØ32)
Ø9.5Ø15.9
Ø26.0 (Hole)
1.12
1.39
60
FBQ60EVE4
RZR60MVM4
6.0(2.6-6.3)
245X1,000X800----------
37
595X845X30043
Hermetically sealed swing typeType Micro channelCross fin coil
1.351.6 (Charged for 30 m)
635/530/44118/15/12.5
1.69
35/33/31
48
71
FBQ71EVE4
RZR71MVM4
7.1 (3.2-8.0)
1.76
2.22
140
FBQ140EVE4
RZR140MVM4
14.0(6.2-15.4)
5.85
4544
Rated 50 (50-150)
100
FBQ100EVE4
RZR100MVM4
990X940X320
10.0 (5.0-11.2)
65
2.031.9(Charged for 30 m)
1,130/953/79432/27/22.5
812/688/56523/19.5/16
2.82
38/35.5/3338/35/33
49 52 54 52 54
125
FBQ125EVE4
RZR125MVM4
12.5 (5.7-14.0)
245X1,400X80047
1,271/1,077/88336/30.5/25
4.58
40/37.5/35
100
FBQ100EVE4
RZR100MYM4
10.0 (5.0-11.2)
1,130/953/794
73
1.92
32/27/22.5
2.82
38/35.5/33
49
3 Phase, 380–415 V, 50 Hz
125
FBQ125EVE4
RZR125MYM4
12.5 (5.7-14.0)
1,271/1,077/88336/30.5/25
4.58
40/37.5/35
140
FBQ140EVE4
RZR140MYM4
14.0(6.2-15.4)
17,100(7,900-19,100)
20,500(8,900-21,500)
24,200(10,900-27,300)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
34,100(17,100-38,200)
42,700(19,500-47,800)
47,800(21,200-52,600)
5.85W/WCOP 3.60 3.56 3.20 2.393.55 2.73 3.55 2.73 2.39
Wh/WhCSPF 5.40 5.20 5.04 4.384.73 4.61 4.73 4.61 4.38
SPECIFICATION (3 Phase)
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3External static pressure is changeable in 11 stages by remote controller.4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.5Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.
Power supply 1 Phase, 220–240 V, 50 Hz1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
ModelName
Indoor unit
Outdoor unit
Indoor unitOutdoor unit
kW
Btu/h
°CDB
°CWB
Cooling
Certified Operation range
Certified Operation range
Motor outputCompressor
Coil
Indoorunit
Dimensions (HXWXD)Air filter5
Colour
mm
dB(A)
kWRefrigerant charge (R-410A)Sound pressure level4
Sound pressure level4 (H/M/L)
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
Machine weight kg
kg
Airflow rate (H/M/L)Fan
Outdoorunit
Colour
Heat insulation
Max. interunit piping length mmMax. installation level difference
Type
----------
Both liquid and gas piping
mmOutdoor unit
Ivory white
kWCooling1Power consumption
Pacfm
Night quiet mode dB(A)
External static pressure3
Cooling capacity1,2
Rated (Min. - Max.)
30
21 to 46
14 to 25
m3/min
50 (Equivalent length 70)
VP25 (I.DØ25XO.DØ32)
Ø9.5Ø15.9
Ø26.0 (Hole)
----------
Rated 50 (50-150)
1,170X900X32097
125
FBQ125EVE4
RZR125LUY14
12.5 (5.7-14.0)
1,271/1,077/88336/30.5/25 18/15/12.5 23/19.5/16
635/530/441 812/688/565 1,271/1,077/883 635/530/441 812/688/56536/30.5/25 18/15/12.5 23/19.5/16
40/37.5/35 35/33/31 38/35/33 40/37.5/35 35/33/31 38/35/33
3.73
245X1,000X800245X1,400X80047 37 47 37
140
FBQ140EVE4
RZR140LUY14
125
FBQ125EVE4
RZR125LVVM4
140
FBQ140EVE4
RZR140LVVM4
14.0(6.2-15.4)
4.71W/WCOP 3.35 2.97
12.5 (5.7-14.0)
3.73
14.0(6.2-15.4)
4.713.35 2.97
3.15 (Charged for 30 m)50
45
2.4 2.9
46
Hermetically sealed scroll typeType Cross fin coil
125
FBQ60EVE4x2
RZR125LUY14
12.5 (5.7-14.0)
3.73
140
FBQ71EVE4x2
RZR140LUY14
125
FBQ60EVE4x2
RZR125LVVM4
140
FBQ71EVE4x2
RZR140LVVM4
14.0(6.2-15.4)
4.713.35 2.97
12.5 (5.7-14.0)
3.73
14.0(6.2-15.4)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
42,700(19,500-47,800)
47,800(21,200-52,600)
4.713.35 2.97
45
2.4 2.9
46
245X1,000X800245X1,400X800
3.7(Charged for 30 m)
45
2.92.4
46 45
2.4 2.9
46
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
FBQ50/60/71/100/125/140E
Thinner design allows greater installation flexibilityThinner design allows greater installation flexibility
Option List
Only one mounting plate can be installed for each indoor unit.Mounting plate is necessary for each adaptor marked .
FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4Name of option Remark
High-efficiency filter1
Filter chamber(for rear suction)1
Long-life filter1
Air discharge adaptor
Adaptor for wiring Wiring adaptor for electrical appendices(2)Remote sensorMounting plate for adaptor PCB.3,4,5
Central remote controller6
Unified ON/OFF controller6
Schedule timer6
intelligent Touch Controller6
Service panel
Remote controller
65%90%
WhiteFresh whiteBrown
Wired type2
Wired type2
Wireless type Cooling only
Kit name
KAFP632B80
Shield plate for side plate
Navigation Remote Controller
KAFP632B160KAFP633B80 KAFP633B160KDDFP63B80 KDDFP63B160KAFP631B80 KAFP631B160KTBJ25K80W KTBJ25K160WKTBJ25K80F KTBJ25K160FKTBJ25K80T KTBJ25K160TKDAP25A71A
KDBD63A160BRC4C66BRC1C61BRC1E62
KRCS01-4BKRP4A98
DCS302CA61DCS301BA61DST301BA61DCS601C51
KDAP25A140A
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required.
3
4Up to 2 adaptors can be fixed for each mounting plate.2Wiring for wired remote controller to be procured locally. 5
6The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
KRP1C64KRP4AA51
DESIGN & INSTALLATION FLEXIBILITY
ADJUSTABLE EXTERNAL STATIC PRESSURE
SILVER ION ANTI-BACTERIAL DRAIN PAN
INTERLOCK CONTROL
SWITCHABLE FAN SPEED
EASY MAINTENANCE
FEATURES
Accessory required for indoor unit.
BRC1C61
Wired LCD Remote Controller
Note: Remote controller cable is not included and must be obtained locally.
A signal receiver must be added to the indoor unit. Wireless LCD remote controller
BRC4C66Signal receiver unit
(Installed type)Wireless remote controller is suppliedin a set with a signal receiver.
BRC1E63
Navigation Remote Controller(Wired Remote Controller)
Note: Remote controller cable is not included and must be obtained locally.
3635
Note: Remote controller cable is not included and must be procured locally.
Wired LCD remote controller
BRC1C61
Accessory required for indoor unit.
BRC1E63 can be
incorporated into the
indoor unit.
(Wired Remote Controller)
Navigation Remote Controller
Note: Remote controller cable is not included and must be procured locally.
BRC1E63
FVQ50/60/71/100/125/140C
New airflow controlfor more comfortNew airflow controlfor more comfort
SPECIFICATION (1 Phase)
Power supply 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
ModelName
Indoor unit
Outdoor unit
Outdoor unit
kW
Btu/h
kWCooling1Power consumption
Cooling capacity1,2
Rated (Min. - Max.)
71
FVQ71CVEB4
RZR71MVM4
60
FVQ60CVE4
RZR60MVM4
50
FVQ50CVE4
RZR50MVM4
7.1 (3.2-8.0)
2.58
140
FVQ140CVEB4
RZR140MVM4
14.0(6.2-15.4)
5.89
100
FVQ100CVEB4
RZR100MVM4
10.0 (5.0-11.2)
3.28
125
FVQ125CVEB4
RZR125MVM4
140
FVQ140CVEB4
RZR140MYM4
100
FVQ100CVEB4
RZR100MYM4
125
FVQ125CVEB4
RZR125MYM4
12.5 (5.7-14.0)
4.62
°CWBCertified Operation range
Indoorunit
Dimensions (HXWXD) mmdB(A)Sound pressure level3 (H/M/L)
Machine weight kg
Airflow rate (H/M/L)Fancfm
14 to 25
m3/min
1,850X600X27039
635/565/49418/16/14
43/41/38988/883/777
28/25/22988/918/847
28/26/241,059/988/918
30/28/26
50/47/441,850X600X350
47
53/51/4851/48/46988/883/777
28/25/22988/918/847
28/26/241,059/988/918
30/28/26
50/47/44 53/51/4851/48/46
°CDB
Cooling
Certified Operation range
Motor outputCompressor
Coil
kWRefrigerant charge (R-410A)Sound pressure level3
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
kg
Outdoorunit
Max. interunit piping length mmMax. installation level difference
Type
mmOutdoor unit
Night quiet mode dB(A)
30
21 to 46
50 (Equivalent length 70)
VP20 (I.DØ20XO.DØ26)
Ø9.5Ø15.9
Ø26.0 (Hole)
595X845X30043
Hermetically sealed swing typeType Cross fin coil Micro channel
1.6 (Charged for 30 m)48
1.761.351.12 1.92
4544990X940X320
65
2.031.9 (Charged for 30 m)
49 52 54
73
49 52 54
W/WCOP 2.75
6.0 (2.6-6.3)
1.843.26
5.0 (2.3-5,6)
1.273.94 2.383.05 2.71
14.0(6.2-15.4)
5.89
10.0 (5.0-11.2)
3.28
12.5 (5.7-14.0)
24,200(10,900-27,300)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
20,500(8,900-21,500)
17,100(7,900-19,100)
47,800(21,200-52,600)
34,100(17,100-38,200)
42,700(19,500-47,800)
4.622.383.05 2.71
Power supply 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
ModelName
Indoor unit
Outdoor unit
Outdoor unit
kW
Btu/h
kWCooling1Power consumption
Cooling capacity1,2
Rated (Min. - Max.)
125
FVQ125CVEB4
RZR125LUY14
12.5 (5.7-14.0)
4.39
140
FVQ140CVEB4
RZR140LUY14
125
FVQ125CVEB4
RZR125LVVM4
140
FVQ140CVEB4
RZR140LVVM4
13.5(6.2-15.4)
5.40W/WCOP 2.85 2.50
12.5 (5.7-14.0)
4.39
13.5(6.2-15.4)
5.402.85
°CWBCertified Operation range
Indoorunit
Dimensions (HXWXD) mmdB(A)Sound pressure level3 (H/M/L)
Machine weight kg
Airflow rate (H/M/L)Fancfm
14 to 25
m3/min 28/26/24 30/28/26 18/16/14 28/26/24 30/28/26 18/16/14988/918/847 1,059/988/918 635/565/494
51/48/461,850X600X350 1,850X600X270
47 39 47 391,850X600X350 1,850X600X270
53/51/48 43/41/38 51/48/46 53/51/48 43/41/38988/918/847 1,059/988/918 635/565/494
2.50
125
FVQ60CVE4x2
RZR125LUY14
12.5 (5.7-14.0)
4.39
140
FVQ71CVEB4x2
RZR140LUY14
125
FVQ60CVE4x2
RZR125LVVM4
140
FVQ71CVEB4x2
RZR140LVVM4
13.5(6.2-15.4)
5.402.85 2.50
12.5 (5.7-14.0)
4.39
13.5(6.2-15.4)
42,700(19,500-47,800)
46,100(21,200-52,600)
42,700(19,500-47,800)
46,100(21,200-52,600)
42,700(19,500-47,800)
46,100(21,200-52,600)
42,700(19,500-47,800)
46,100(21,200-52,600)
5.402.85 2.50
Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)2Capacities are net, including a deduction for cooling for indoor fan motor heat.3The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
°CDB
Cooling
Certified Operation range
Motor outputCompressor
Coil
kW
Refrigerant charge (R-410A)Sound pressure level3
dB(A)
Dimensions (HXWXD) mmMachine weight kg
Piping connections
mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit
kg
Outdoorunit
Max. interunit piping length mmMax. installation level difference
Type
mmOutdoor unit
Night quiet mode dB(A)
30
21 to 46
50 (Equivalent length 70)
VP20 (I.DØ20XO.DØ26)
Ø9.5Ø15.9
Ø26.0 (Hole)
1,170X900X320
5045
97
2.8 3.4
46
3.15 (Charged for 30 m)
45
2.4 3.1
46
Hermetically sealed scroll typeType Cross fin coil
3.7 (Charged for 30 m)
45
2.8 3.4
4645
2.4 3.1
46
SPECIFICATION (3 Phase)
Option ListKit name
Name of optionFVQ71CVEB4 FVQ100CVEB4FVQ50CVE4 FVQ60CVE4
DCS302CA61DCS301BA61DST301BA61
KAFJ95L160
Remark
Replacement long-life filterBRC1C61Remote controller
Navigation Remote ControllerCentral remote controller2
Unified ON/OFF controller2
Schedule timer2
intelligent Touch Controller2
Adaptor for wiring3
Wiring adaptor for electrical appendicesInstallation box for adaptor PCB
Note: 1Wiring for wired remote controller to be procured locally. 2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA95) is necessary.
FVQ125CVEB4 FVQ140CVEB4
KRP1BA57DCS601C51
KRP4AA52KRP4AA95
BRC1E62Wired type1
Wired type1
NEW COMFORTABLE AIRFLOW CONTROL
LONG-LIFE FILTER
SWITCHABLE FAN SPEED
SAFETY LOCK FUNCTION OF SUCTION GRILLE
QUIET OPERATION
QUICK & EASY TO INSTALL & MAINTENANCE
FEATURES
FLOOR STANDING TYPE
3837