Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in...

100
Catalogue 2004/2005 Air Conditioning Program R 407C R 410A More than Air Conditioning

Transcript of Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in...

Page 1: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

Catalogue 2004/2005Air Conditioning ProgramR 407CR 410A

More than Air Conditioning

Page 2: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

As one of the world’s leading technology companies,MITSUBISHI ELECTRIC is committed to providingproducts and solutions which will enhance the quality of our lives – at home, at work and at play.Our outstanding range of split and multi-split air conditioning systems reflect this philosophy.Whether you are an installer, specifier or user, you willappreciate the combination of quality, energy-efficiency,reliability and ease-of-installation that MITSUBISHI ELECTRIC Environmental Control products offer.

MITSUBISHI ELECTRICAir Conditioning Systems

Page 3: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

New technology, more comfort, more energy-efficiency - high-quality air conditioners of MITSUBISHI ELECTRIC!

Product series

The program offers you more choice than ever before. So whatever the application - a shopping centre, a hotel,restaurant, shop or even a domestic home - the differentproduct series provide the optimum fit.

Units of the M Series are designed for smaller rooms, eachoutdoor unit requires up to 4 indoor units.

The Mr. Slim Series is applied for middle-sized rooms and isavailable as single-split and as multi-split system in parallelmode.

The City Multi Series convinces with cooling capacity of 14 kW till 84 kW in a refrigerant cycle used for big projects.

New technology

The inverter technology and new refrigerant R410A enablemore energy efficiency. All indoor units can be controlledseparately for customised adjustment of temperature.

Easy installation

The environment-friendly systems of MITSUBISHI ELECTRICcan be installed with minimum work. Space-saving andcompact units are available for wall or floor mounting - for a flexible planning and design of structures. The air conditioning systems are expandable for subsequent increasing of the capacity at any time.

Rating conditions

COOLING Indoor: 27°C DB / 19°C WBOutdoor: 35°C DB / 24°C WBOutdoor water temperature for WR2 30°C

HEATING Indoor: 20°C DBOutdoor: 7°C DB / 6°C WBOutdoor water temperature for WR2 20°CRefrigerant piping length 5 m / 7.5 m* (one way)�H = 0 mSound pressure level measured in anechoicroom, at a position 1 m in front of the outdoor unit* For PUH-P8/10MYA and City Multi

Contents

M-Series

M-SeriesAccessories

Mr. Slim-R407C-Series

Mr. Slim-R410A-SeriesPower Inverter

Mr. Slim-SeriesAccessories

City Multi-Series

City Multi-SeriesAccessories

LossnayVentilationSeries

Dehumidifier

In-ceiling cassettes

Wall mounted systems

Floor standing units

Ceiling suspended systems

Above ceiling concealedducted systems

4

24

26

62

70

3

74

88

94

98

Page 4: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

The outstanding M Series brings legendary Mitsubishi Electric quality to the low-capacity air conditioning class. M Series units are perfect for small living spaces like of-fices, restaurants and small shops, where their unobtrusiveappearance and quiet operation are important advantages.

Ultra-energy-efficient

M Series systems are designed to give lowest possible running costs, with innovative energy-saving features like `Econo-Cool´, which direct airflow towards room occupants. This can allow set temperatures to be raised by 2°C with no loss in comfort and a 20% gain in energy efficiency.

M SeriesSplit- and Multi-Split SystemsCooling 2.3 kW - 8.5 kW

4

Page 5: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

Plus ...● Optional high-efficiency air

cleaning filters; deodorisingand antibacterial Catechin filters available for wall-mounted systems

● Rapid room cooling withswing mode feature

● Remote control of five different angles of airflow to reach ideal temperatures in optimum time

MSC Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

MS Cooling Only Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

MSC Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

MSH Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

MCF Cooling Only Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

MCFH Cooling/Heating Floor or Ceiling Mounted Systems . . . . . . . . . . . . . . . . . . . . . . . 11

MSZ Inverter Single Split Cooling/Heating Wall Mounted Systems . . . . . . . . . . . . . . . . . 12

SLZ Inverter Cooling/Heating 4-Ceiling Cassette Systems. . . . . . . . . . . . . . . . . . . . . . . . 14

SEZ Inverter Cooling/Heating Ceiling Concealed Systems . . . . . . . . . . . . . . . . . . . . . . . 15

MSX Multi Split Systems Cooling Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

MXZ Inverter Multi Split Systems Cooling/Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

M SERIES Accessories/Optional Parts/Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Range of M Series● Cooling Indoor: 21° - 32°C DB

15° - 23°C WBOutdoor: 21° - 43°C DB Non-Inverter models and

MXZ-A18 WV-15° - 43°C DB Inverter types

● Heating Indoor: 20° - 27°C DBOutdoor: - 9° - 21°C DB

-10° - 15°C WB

5

● A wide range of indoor unitsand dual-use units for eitherfloor or ceiling installation

● Quick and easy installation● Auto restart function● Winterkit in cooling mode

up to -15°C for inverter models and a wind-protectedinstallation

Lowest noise levels

With noise levels down to just 21 dB(A)

Excellent control features

M Series remote controllers incorporate easy-to-use features like `IFeel´ control, which memorises the user`s ideal tem-perature and recreates it precisely.

Multi-splits

The M Series includes split system models, running up to four in-door units from one outdoor unit.

Page 6: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

6

MSC Cooling OnlyWall Mounted Systems

Series

● Energy-saving rotary pistoncompressor

● Extremely quiet operation withnoise level of only 25 dB(A)*

● `Swing Mode´-function ena-bles automatically a more na-tural and comfortable airflowthroughout the room

● Factory charged with refrige-rant R410A

● Hand-held controller with `fu-zzy logic´ control

● Remote control for five diffe-rent angles of airflow direction

● Auto restart function● 24 h Timer● Long-life and washable Cate-

chin filters for deodorisingand prevention of bacteriaand viruses

Accessories:Additional filters available to keep air fresh, please view page 24

* MCS-A07/09YV

MSC COOLING ONLY - WALL MOUNTED SYSTEMSINDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kW) Cooling 2.3 2.55 3.5AIRFLOW (m3/h) Low 276 306 324

High 474 474 582NOISE dB(A) Low 25 25 26

High 36 36 40WEIGHT (kg) 9 9 10DIMENSIONS (mm) Width 815 815 815

Depth 244 244 244Height 278 278 278

ELECTRICAL SUPPLY220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.17 0.17 0.19OUTDOOR UNIT MU-A07YV MU-A09YV MU-A12YVPOWER CONSUMPTION (kW)

Cooling 0.715 0.795 1.14AIRFLOW (m3/h)

1686 1686 1914

NOISE dB(A) 45 45 49WEIGHT (kg) 34 34 36DIMENSIONS (mm) Width 780 780 780

Depth 255 255 255Height 540 540 540

MAX. PIPE LENGTH (m) 20 20 25MAX. HEIGHT DIFFERENCE (m) 10 10 10CHARGE R410A* (kg) 0.60 0.60 0.75PIPE SIZE Liquid 6 6 6ø (mm) Gas 10 10 12ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) 3.00 3.32 4.92

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 min front of and 0.8 m below the unit in anechoic chamber

Page 7: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

7

MS Cooling OnlyWall Mounted Systems

Series

● Energy-saving rotary pistoncompressor

● Compact indoor units - easyto install

● `Swing Mode´-function enables automatically a morenatural and comfortable airflow throughout the room

● Factory charged with refrigerant R410A

● Hand-held controller with `fuzzy logic´ control

● Remote control for five different angles of airflow direction

● Auto restart function● 24 h Timer● Long-life and washable

Catechin filters for deodorising and preventionof bacteria and viruses

Accessories:Additional filters available to keep air fresh, please view page 24

MS COOLING ONLY - WALL MOUNTED SYSTEMSINDOOR UNIT MS-A18WV MS-A24WV MS-A30WV CAPACITY (kW) Cooling 5.0 6.5 8.5AIRFLOW (m3/h) Low 528 588 684

High 768 768 960NOISE dB(A) Low 34 37 37

High 42 45 47WEIGHT (kg) 16 16 16DIMENSIONS (mm) Width 1100 1100 1100

Depth 227 227 227Height 325 325 325

ELECTRICAL SUPPLY220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.30 0.30 0.34OUTDOOR UNIT MU-A18WV MU-A24WV MU-A30WVPOWERCONSUMPTION (KW) Cooling 1.81 2.48 3.26AIRFLOW (m3/h)

2196 2760 2940

NOISE dB(A) 52 53 55WEIGHT (kg) 44 60 85DIMENSIONS (MM) Width 850 850 840

Depth 290 290 330Height 605 605 850

MAX. PIPE LENGTH (m) 25 25 30MAX. HEIGHT DIFFERENCE (m) 10 10 15CHARGE R410A* (kg) 1.40 1.90 2.30PIPE SIZE Liquid 6 6 10ø (mm) Gas 12 16 16ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A)) 7.93 10.39 14.42

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and0.8 m below the unit in anechoic chamber

Page 8: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

8

MSC Cooling/HeatingWall Mounted Systems

Series

● True comfort year-round● Compact indoor units -

easy to install● Extremely quiet operation with

noise level of only 25 dB(A)*● `Swing Mode´-function

for a quick cooling and comfortable airflow through-out the room

● Energy-saving rotary pistoncompressor

● Factory charged with refrigerant R410A

● Hand-held controller with `fuzzy logic´ control

● Remote control for five different angles of airflow direction

● Auto restart function● 24 h Timer● Long-life and washable

Catechin filters for deodorising and preventionof bacteria and viruses

Accessories:Additional filters availableto keep air fresh,please view page 24

* MSC-A07/09YV

MSC COOLING/HEATING - WALL MOUNTED SYSTEMSINDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YV CAPACITY (kW) Cooling 2.3 2.55 3.5

Heating 2.5 3.05 3.9AIRFLOW (m3/h) Low 276 306 324

High 474 474 582NOISE dB(A) Low 25 25 26

High 36 36 40WEIGHT (kg) 9 9 10DIMENSIONS (mm) Width 815 815 815

Depth 244 244 244Height 278 278 278

ELECTRICAL SUPPLY220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.17 0.17 0.19OUTDOOR UNIT MUH-A07YV MUH-A09YV MUH-A12YVPOWER CONSUMPTION (kW) Cooling 0.715 0.795 1.09

Heating 0.69 0.84 1.08AIRFLOW (m3/h)

1686 1710 1710

NOISE dB(A) 47 49 49WEIGHT (kg) 35 38 40DIMENSIONS (mm) Width 780 780 780

Depth 255 255 255Height 540 540 540

MAX. PIPE LENGTH (m) 20 20 25MAX. HEIGHT DIFFERENCE (m) 10 10 10CHARGE R410A* (kg) 0.62 1.00 1.00PIPE SIZE Liquid 6 6 6ø (mm) Gas 10 10 12ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) 3.00 3.32 4.65

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber (cooling mode)

Page 9: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

9

MSH Cooling/HeatingWall Mounted Systems

Series

● True comfort year-round● Compact indoor units -

easy to install● `Swing Mode´-function for a

quick cooling and comfort-able airflow throughout theroom

● Energy-saving rotary pistoncompressor

● Factory charged with refrigerant R410A

● Hand-held controller with`fuzzy logic´ control

● Remote control for five differ-ent angles of airflow direction

● Auto restart function● 24 h Timer

● Long-life and washable Catechin filters for deodorising and preventionof bacteria and viruses

Accessories:Additional filters available to keep air fresh,please view page 24

MSH COOLING/HEATING – WALL MOUNTED SYSTEMSINDOOR UNIT MSH-A18WV MSH-A24WV MSH-A30WV CAPACITY (kW) Cooling 5.0 6.3 8.5

Heating 5.2 7.2 9.4AIRFLOW (m3/h)) Low 528 588 684

High 768 768 960NOISE dB(A) Low 34 37 37

High 42 45 47WEIGHT (kg) 16 16 16DIMENSIONS (mm) Width 1100 1100 1100

Depth 227 227 227Height 325 325 325

ELECTRICAL SUPPLY220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.30 0.30 0.34OUTDOOR UNIT MUH-A18WV MUH-A24WV MUH-A30WVPOWER Cooling 1.78 2.41 3.26CONSUMPTION (kW) Heating 1.61 2.48 3.43AIRFLOW (m3/h))

2196 2760 2940

NOISE dB(A) 52 53 55WEIGHT (kg) 47 74 87DIMENSIONS (mm) Width 850 840 840

Depth 290 330 330Height 605 850 850

MAX. PIPE LENGTH (m) 25 25 30MAX. HEIGHT DIFFERENCE (m) 10 10 15CHARGE R410A* (kg) 1.75 2.15 2.30PIPE SIZE Liquid 6 6 10ø (mm) Gas 12 16 16ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) 7.93 10.39 14.42

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit inanechoic chamber (cooling mode)

Page 10: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

10

MCF Cooling OnlyFloor or Ceiling Mounted Systems

Series

● Versatile 2-in-1 design supplied with multi-purposebrackets for floor-standing orceiling-suspension

● Hand-held controller with`fuzzy logic´ control

● Lightweight and compact design for easy installation

● Readily access for pipe connections and maintenance

● Quiet operation noise● Adjustment of five different

angles of airflow direction

● Three fan-stages or automatic set-up angles ofairflow direction

● `Swing Mode´-function for aquick cooling and comfortableairflow throughout the room

● Factory charged with refrigerant R410A

● Auto restart function● 24 h Timer

Accessories:Additional filters available to keep air fresh,please view page 24

MCF COOLING ONLY - FLOOR OR CEILING MOUNTED SYSTEMSINDOOR UNIT MCF-A12WV MCF-A18WV MCF-A24WVCAPACITY (kW) Cooling 3.5 4.8 6.0AIRFLOW (m3/h) Low 474 492 642

High 678 780 840NOISE dB(A) Low 34 36 42

High 44 46 48WEIGHT (kg) 25 25 25DIMENSIONS (mm) Width 1100 1100 1100

Depth 180 180 180Height 650 650 650

ELECTRICAL SUPPLY220-240, 1, 50 (V, PHASE, Hz)

RUNNING CURRENT (A) 0.26 0.36 0.39OUTDOOR UNIT MU-A12YV MUCF-A18WV MUCF-A24WVPOWER CONSUMPTION (kW) Cooling 1.16 1.81 2.45AIRFLOW (m3/h)

1914 2196 2760

NOISE dB(A) 49 52 53WEIGHT (kg) 36 44 60DIMENSIONS (mm) Width 780 850 850

Depth 255 290 290Height 540 605 605

MAX. PIPE LENGTH (m) 25 25 25MAX. HeightNDIFFERENZ (m) 10 10 10CHARGE R410A* (kg) 0.75 1.2 1.8PIPE SIZE Liquid 6 6 6ø (mm) Gas 12 12 16ELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE,Hz)RUNNING CURRENT (A) 4.89 7.92 10.59

* Factory charged to 7 m pipe length, optional charging on page 25The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing) the unit in anechoic chamber

Page 11: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

11

Series MCFH Cooling/HeatingFloor or Ceiling Mounted Systems

● Versatile 2-in-1 design supplied with multi-purposebrackets for floor-standing orceiling-suspension

● Lightweight and compact design for easy installation

● Comfortable temperature thewhole year round

● Quiet operation noise● Hand-held controller with

fuzzy-logic control● Adjustment of five different

angles of airflow direction● 24 h Timer● Factory charged with

refrigerant R410A

● Readily access for pipe con-nections and maintenance

● Three fan-stages or automaticset-up angles of airflow direction

Accessories:Additional filters available tokeep air fresh,please view page 24

MCFH COOLING/HEATING - FLOOR OR CEILING MOUNTED SYSTEMSINDOOR UNIT MCFH-A12WV MCFH-A18WV MCFH-A24WVCAPACITY (kW) Cooling 3.5 4.8 6.0

Heating 3.7 5.0 6.8AIRFLOW(m3/h) Low 492 570 642

Mittel 636 696 744High 780 840 840

NOISE dB(A) Low 36 39 42High 46 48 48

WEIGHT (kg) 25 25 25DIMENSIONS (mm) Width 1100 1100 1100

Depth 180 180 180Height 650 650 650

ELECTRICAL SUPPLY220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.30 0.36 0.36OUTDOOR UNIT MUH-A12YV MUCFH-A18WV MUCFH-A24WVPOWER Cooling 1.16 1.81 2.45CONSUMPTION (kW) Heating 1.02 1.89 2.72AIRFLOW(m3/h)

1710 2196 2760

NOISE dB(A) 49 52 53WEIGHT (kg) 40 47 74DIMENSIONS (mm) Width 780 850 840

Depth 255 290 330Height 540 605 850

MAX. PIPE LENGTH (m) 25 25 25MAX. HEIGHT DIFFERENCE (m) 10 10 10CHARGE R410A* (kg) 1.0 1.75 2.15PIPE SIZE Liquid 6 6 6ø (mm) Gas 12 12 16ELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) 4.85 8.01 10.51

* Factory charged to 7 m pipe length, optional charging on page 25The noise levels are measured at a position 1.0 m in front of and 0.8 m below (ceiling mounted) / 1.0 m below (floor standing)the unit in anechoic chamber

Page 12: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

12

MSZ Inverter Single-SplitCooling/HeatingWall Mounted Systems

Series

● Compact indoor units - easy to install

● Easy and quick cleaning with`Quick Clean Body´-system

● Extremely quiet operationwith noise level of only 21dB(A) (MSZ-A09YV)

● Energy-saving inverter technology provides highestcomfort year-round

● `Swing Mode´-function for aquick cooling and comfort-able airflow throughout theroom

● Factory charged with refrigerant R410A

● Hand-held controller with`fuzzy logic´ control

MSZ INVERTER SINGLE-SPLIT, COOLING/HEATINGINDOOR UNIT MSZ-A09YV MSZ-A12YVCAPACITY (kW) Cooling 2.5 (0.9 - 3.2) 3.5 (1.0 - 4.1)

Heating 3.2 (0.9 - 5.0) 4.0 (0.9 - 6.0)AIRFLOW (m3/h) Low 222 288

High 504 630NOISE dB(A) Low 21 22

High 37 39WEIGHT (kg) 9 10DIMENSIONS (mm) Width 815 815

Depth 244 244Height 278 278

ELECTRICAL SUPPLY220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.17 0.19OUTDOOR UNIT MUZ-A09YV MUZ-A12YVPOWER Cooling 0.67 1,09CONSUMPTION (kW) Heating 0.84 1.08AIRFLOW(m3/h)

1900 1900

NOISE dB(A) 46 47WEIGHT (kg) 33 34DIMENSIONS (mm) Width 800 800

Depth 285 285Height 550 550

MAX. PIPE LENGTH (m) 20 20MAX. HEIGHT DIFFERENCE (m) 12 12CHARGE R410A* (kg) 0.80 0.90PIPE SIZE Liquid 6 6ø (mm) Gas 10 10ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) 3.3 5.0

● Remote control for five different angles of airflow di-rection

● 24 h Timer● Long-life and washable

Catechin filters for deodoris-ing and prevention of bacteria and viruses

● Winterkit in cooling mode upto -15° C, view page 5

Accessories:● Additional filters available to

keep air fresh,please view page 24

● Quick clean kit for connec-tion to household vacuum cleaner

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 mbelow the unit in anechoic chamber (cooling mode)

Page 13: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

13

MSZ Inverter Single-SplitCooling/HeatingWall Mounted Systems

Series

● Compact indoor units - easy to install

● Easy and quick cleaning with`Quick Clean Body´-system

● Energy-saving inverter technology provides highestcomfort year-round

● `Swing Mode´-function for aquick cooling and comfort-able airflow throughout theroom

● Factory charged with refrigerant R410A

● Hand-held controller with`fuzzy logic´ control

● Remote control for five different angles of airflow direction

● 24 h Timer● Long-life and washable

Catechin filters for deodorising and preventionof bacteria and viruses

● Winterkit in cooling mode upto -15° C, view page 5

Accessories:Additional filters available to keep air fresh,please view page 24

MSZ INVERTER SINGLE SPLIT, COOLING/HEATINGINDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YVCAPACITY (kW) Cooling 5.0 (0.9 - 5.9) 6.0 (0.9 - 6.7) 7.1 (0.9 - 8.1)

Heating 6.25 (0.9 - 7.8) 7.0 (0.9 - 8.1) 8.5 (0.9 - 9.5)AIRFLOW (m3/h) Low 486 510 552

High 828 1020 1020NOISE dB(A) Low 32 33 33

High 47 47 47WEIGHT (kg) 16 16 16DIMENSIONS (mm) Width 1100 1100 1100

Depth 258 258 258Height 325 325 325

ELECTRICAL SUPPLY220-240, 1, 50 (V, PHASE, Hz)

RUNNING CURRENT (A) 0.3 0.3 0.34OUTDOOR UNIT MUZ-A18YV MUZ-A24YV MUZ-A26YVPOWER Cooling 1.56 1.99 2,35CONSUMPTION (kW) Heating 1.73 2.05 2.65AIRFLOW (m3/h)

2940 2940 2940

NOISE dB(A) 55 55 55WEIGHT (kg) 72 72 80DIMENSIONS (mm) Width 840 840 840

Depth 330 330 330Height 850 850 850

MAX. PIPE LENGTH (m) 30 30 30MAX. HEIGHT DIFFERENCE (m) 15 15 15CHARGE R410A* (kg) 1.80 2.20 2.35PIPE SIZE Liquid 6 6 10ø (mm) Gas 12 16 16ELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE,Hz)RUNNING CURRENT (A) 6.9 8.8 11.0

* Factory charged to 7 m pipe length, optional charging on page 25The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m belowthe unit in anechoic chamber (cooling mode)

Units available approx. July/August 2004

Page 14: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

14

Series SLZ Inverter Cooling/HeatingIn-Ceiling Cassette Systems

● The standardised Euro-spacingfacilitates installation in existinginserted ceilings

● The required installation heightis only 235 mm

● Quiet operation with noise levelof only 32 dB(A)*

● Low weight of 16.5 kg - easy to install

● Best airflow adjustment bythree fan stages

● Long-life filters to keep airfresh, cleaning necessary onlyafter 2,500 hours of normal operation

● Equipped with drain pump,delivery height 500 mm

● Fresh air intake● Infrared controller with

12-hours on/off-timer● Auto restart function● Factory charged with R410A● Winterkit in cooling mode up

to -15° C, view page 5

* SLZ-A09AR

SLZ INVERTER COOLING/HEATING - IN-CEILING CASSETTE SYSTEMSINDOOR UNIT SLZ-A09AR SLZ-A12AR SLZ-A18ARGRILLE SLP-2AL SLP-2AL SLP-2ALCAPACITY (kW) Cooling 2.5 (0.9 - 3.2) 3.2 (1.0 - 4.1) 4.3 (0.9 - 5.0)

Heating 3.0 (0.9 - 3.7) 3.8 (0.9 - 4.8) 4.8 (0.9 - 5.6)AIRFLOW (m3/h) Low 480 540 540

Middle 540 600 600High 600 660 660

NOISE dB(A) Low 32 34 35High 38 39 40

WEIGHT (KG) (kg) 16.5/19.5 16.5/19.5 16.5/19.5DIMENSIONS (mm) Width 570 570 570Indoor unit Depth 570 570 570

Height* 235 235 235DIMENSIONS (mm) Width 650 650 650Grille Depth 650 650 650

Height** 20 20 20ELECTRICAL SUPPLY

220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) 0.4 0.6 0.62OUTDOOR UNIT SUZ-A09VR SUZ-A12VR SUZ-A18VRPOWER Cooling 0.76 1.06 1.53CONSUMPTION (kW) Heating 0.87 1.07 1.50AIRFLOW (m3/h)

1900 1900 2940

NOISE dB(A) 46 47 55WEIGHT (kg) 33 34 72DIMENSIONS (mm) Width 800 800 840

Depth 285 285 330Height 550 550 850

MAX. PIPE LENGTH (m) 20 20 30MAX. HEIGHT DIFFERENCE (m) 12 12 15CHARGE R410A*** (kg) 0.8 0.9 1.4PIPE SIZE Liquid 6 6 6ø (mm) Gas 10 10 12ELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) 3.7 4.9 7.4

*** Required installation height*** Visible height of grille*** Factory charged to 7 m pipe length, optional charging on page 25The noise levels are measured at a position 1.5 m below the unit in anechoic chamber (cooling mode)

Page 15: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

15

● Quiet operation of indoor andoutdoor units

● Compact, easy-to-install design (only 270 mm height)

● Low power consumption foreconomy of use

● Direct driven, forward curvedcentrifugal fan for maximumair throw

● Self diagnostic trouble shooting function

● Air intake options for entry atback or base of indoor unit

● High quality remote controlwith service display and 12 h-timer

● Factory charged with refrigerant R410A

● Auto restart function● Winterkit in cooling mode up

to -15°, view page 5● Air filters PAC-1000 FT

included in delivery

SEZ Inverter Cooling/HeatingCeiling Concealed Systems

SEZ INVERTER COOLING/HEATING - CEILING CONCEALED SYSTEMSINDOOR UNIT SEZ-A12AR SEZ-A18AR SEZ-A24ARCAPACITY (kW) Cooling 3.4 (1.0 - 4.3) 4.7 (0.9 - 5.6) 5.4 (0.9 - 6.1)

Heating 3.9 (0.9 - 4.9) 5.7 (0.9 - 6.6) 6.5 (0.9 - 7.4)AIRFLOW (m3/h) Low 600 720 720

High 780 1020 1200

EXTERNAL STATIC PRESSURE (Pa) 30 (50) 30 (50) 30 (50)NOISE dB(A) Low 30 31 32

High 35 39 43WEIGHT (kg) 33.5 33.5 33.5DIMENSIONS (mm) Width 1100 1100 1100

Depth 700 700 700Height 270 270 270

ELECTRICAL SUPPLY220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) 0.59 0.68 0.95OUTDOOR UNIT SUZ-A12VR SUZ-A18VR SUZ-A24VRPOWER Cooling 1.10 1.67 1.92CONSUMPTION (kW) Heating 1.11 1.78 2.02AIRFLOW (m3/h) 1900 1900 2196NOISE dB(A) 47 55 55WEIGHT (kg) 34 72 72DIMENSIONS (mm) Width 800 840 840

Depth 285 330 330Height 550 850 850

MAX. PIPE LENGTH (m) 20 30 30MAX. HEIGHT DIFFERENCE (m) 12 15 15CHARGE* R410A (kg) 0.8 0.9 1.4PIPE SIZE Liquid 6 6 6Ø (mm) Gas 10 12 16ELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) 5.0 8.0 9.0

Series

* Factory charged to 7 m pipe length, for further information please view page 25The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber

Page 16: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

16

Series MSX Multi-SplitCooling OnlyWall Mounted Systems

MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YVCAPACITY (kW) Cooling Depending on combinations, view pages 17-19

AIRFLOW (m3/h) Low 276 306 324High 474 474 582

NOISE dB(A) Low 25 25 26High 36 36 40

WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815

Depth 244 244 244Height* 278 278 278

ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50RUNNING CURRENT (A) 0.17 0.17 0.19 POWER CONSUMPTION (W) 35 35 40PIPE SIZE Liquid 6 6 6ø (mm) Gas 10 10 12

COMBINATION WITH 2 WALL MOUNTED INDOOR UNITS:OUTDOOR UNIT MUX-A10WV MUX-A19WV MUX-A25WVCAPACITY (kW) Cooling 2.8 5.9 7.0CONNECTABLE INDOOR Number 1 - 2 1 - 2 1 - 2UNITS Type 2 x 07 1 x 07 + 1 x 12 2 x 12AIRFLOW (m3/h) 1914 2460 2460NOISE dB(A) 49 52 52WEIGHT (kg) 35 66 68DIMENSIONS (mm) Width 780 840 840

Depth 255 330 330 Height 540 640 640

TOTAL PIPE LENGTH (m) 30 30 30MAX. PIPE LENGTH per indoor unit (m) 15 15 15MAX. HEIGHT DIFFERENCE DIFFERENCE (m)

10 10 10

COMPRESSORS (pc) 1 2 2

CHARGE R410A (kg)* Quantity 0.90 (2 x 0.7) 1.0 (12) 0.95 (12)

Apportionment – 0.8 (07) 0.95 (12)

Charge for (m) 10 (2 x 0.7) 7 (12) 7 (12)

Apportionment – 7 (07) 7 (12)PIPE SIZE Liquid 2 x 6 2 x 6 2 x 6ø (mm) Gas 2 x 10 1 x 10/ 1 x 12 2 x 12ELECTRICAL SUPPLY (V, Phase, Hz) 220-240, 1, 50RUNNING CURRENT (A) 3.59 9.32 11.87POWERCONSUMPTION (kW) 0.8 2.08 2.64

Advantages:● Cooling capacity between 2.8

kW and 7.3 kW per outdoorunit

● Up to four wall mounted indoor units with different capacity can be connectedfor cooling 2, 3 or 4 rooms

● Independent infrared controller with 24-hourson/off-timer

● Expandable system, units can be added at any time

● Multi-Split configurations provide greater economy andcomfort due to quiet opera-tion noise, MSC-A07/09 YVonly 25 dB(A)

● The energy-saving rotarycompressor enables quieteconomical performance

● Auto restart function● Refrigerant R410A

The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 mbelow the unit in anechoic chamber

* The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25

Page 17: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

17

MSX Multi-Split SystemsCooling Only - 2 Wall Mounted Indoor Units

Series

Twin Combination:

MSX-A10WV ● 2.8 kW cooling capacity● up to 2 connectable indoor units

2 x MSC-A07YV

MSX-A19WV ● 5.9 kW cooling capacity● up to two connectable indoor units

1 x MSC-A07YV1 x MSC-A12YV

MSX-A25WV ● 7.0 kW cooling capacity● up to two connectable indoor units

2 x MSC-A12YV

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT

MSC-A07YV MSC-A07YV1 indoor unit 2.40 –

– 2.40

2 indoor unit 1.40 1.40

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT

MSC-A12YV MSC-A07YV1 indoor unit 3.50 –

– 2.40

2 indoor unit 3.50 2.40

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT

MSC-A12YV MSC-A12YV1 indoor unit 3.50 –

– 3.50

2 indoor unit 3.50 3.50

MUX-A10WV

MSC-A07YV

MSC-A07YV

MUX-A19WV

MSC-A12YV

MSC-A07YV

MUX-A25WV

MSC-A12YV

MSC-A12YV

Page 18: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

18

Series MSX Multi-Split Systems Cooling Only - 3 or 4 Wall Mounted Indoor Units

MSC WALL MOUNTED INDOOR UNITS INDOOR UNIT MSC-A07YV MSC-A09YV MSC-A12YVCAPACITY (kW) Cooling Depending on combinations, view pages 17-19

AIRFLOW (m3/h) Low 276 306 324High 474 474 582

NOISE dB(A) Low 25 25 26High 36 36 40

WEIGHT (kg) 9 9 10 DIMENSIONS (mm) Width 815 815 815

Depth 244 244 244Height 278 278 278

ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50RUNNING CURRENT (A) 0.17 0.17 0.19 POWER CONSUMPTION (W) 35 35 40PIPE SIZE Liquid 6 6 6ø (mm) Gas 10 10 12

COMBINATION WITH 3 OR 4 WALL MOUNTED INDOOR UNITS:OUTDOOR UNIT MUX-A20WV MUX-A22WV MUX-A26WVCAPACITY (kW) Cooling 6.0 6.5 7.3CONNECTABLE INDOOR Number 1 - 3 1 - 3 1 - 4UNITS Type 3 x 09 2 x 07 + 1 x 12 2 x 09 + 2 x 12AIRFLOW (m3/h) 2460 2460 2760NOISE dB(A) 52 52 52WEIGHT (kg) 65 67 77DIMENSIONS (mm) Width 840 840 840

Depth 330 330 330 Height 640 640 850

TOTAL PIPE LENGTH (m) 45 45 60MAX. PIPE LENGTH per indoor unit (m) 15 15 15MAX. HEIGHTDIFFERENCE (m)

10 10 10

COMPRESSORS (pc) 2 2 2

CHARGE R410A (kg)* Quantity 0.80 (09) 0.85 (12) 1.05 (2 x 09)

Apportionment 1.0 (2 x 09) 0.85 (2 x 07) 1.05 (2 x 12)

Charge for (m) 7 (09) 7 (12) 10 (2 x 09)

Apportionment 10 (2 x 09) 10 (2 x 07) 10 (2 x 12)PIPE SIZE Liquid 3 x 6 3 x 6 4 x 6ø (mm) Gas 3 x 10 2 x 10 / 1 x 12 2 x 10 / 2 x 12ELECTRICAL SUPPLY (V, Phase, Hz) 220-240, 1, 50RUNNING CURRENT (A) 8.92 8.92 10.47POWER CONSUMPTIONincl. indoor units (kW) 1.99 1.98 2.36

The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 mbelow the unit in anechoic chamber

* The values in brackets refer to the connected indoor units MSC-A07/09/12YV, optional charging on page 25

Page 19: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

19

MSX-A20WV

TRIPLE COMBINATION:

● 6.0 kW cooling capacity● up to 3 connectable indoor units

3 x MSC-A09YV

MSX-A26WV ● 7.3 kW cooling capacity● up to 4 connectable indoor units

2 x MSC-A12YV2 x MSC-A09YV

MUX-A26WV

MSC-A12YV

MSC-A09YV

MSC-A12YV

MSC-A09YV

MSC-A09YV

MUX-A20WV MSC-A09YV

MSC-A09YV

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT

MSC-A09YV MSC-A09YV MSC-A09YV

1 indoor unit 2.60 – –– 2.90 –– – 2.90

2 indoor unit 2.60 2.80 –2.60 – 2.80

– 1.75 2.00

3 indoor unit2.50 1.75 1.75

● 6.5 kW cooling capacity● up to 3 connectable indoor units

1 x MSC-A12YV2 x MSC-A07YV

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT

MSC-A12YV MSC-A07YV MSC-A07YV

1 indoor unit 3.50 – –– 2.40 –– – 2.40

2 indoor unit 3.50 2.40 –3.50 – 2.40

– 1.45 1.45

3 indoor unit 3.40 1.45 1.45

MSX-A22WVMSC-A12YV

MUX-A22WV MSC-A07YV

MSC-A07YV

COOLING CAPACITY (kW)OPERATION INDOOR UNIT INDOOR UNIT INDOOR UNIT INDOOR UNIT

MSC-A12YV MSC-A12YV MSC-A09YV MSC-A09YV

1 indoor unit 3.40 – – –– 3.40 – –– – 2.75 –– – – 2.75

2 indoor unit 1.95 1.95 – –3.40 – 2.70 –3.40 – – 2.70

– 3.40 2.70 –– 3.40 – 2.70– – 1.70 1.70

3 indoor unit 1.95 1.95 2.80 –1.95 1.95 – 2.803.40 – 1.70 1.70

– 3.40 1.70 1.70

4 indoor unit 1.95 1.95 1.70 1.70

Page 20: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

20

MXZ Inverter Multi-SplitSystems Cooling/Heating

Series

● Energy-saving invertertechnology provides highestcomfort year-round

● Very quiet operation● Factory charged with R410A● Can operate with up to four

indoor units connected● Various indoor units available:

Wall mounted systems, flooror ceiling mounted systems,ceiling concealed system andin-ceiling cassette system

● Combination of indoor units with different capacitypossible

● Special control retains customised temperature adjustment

● Auto restart function● Winterkit in cooling mode up

to -15° C*, view page 5

* for MXZ-A26/32 WV

MXZ INVERTER MULTI-SPLIT SYSTEMS COOLING/HEATINGOUTDOOR UNIT MXZ-A18WV MXZ-A26WV MXZ-A32WVCAPACITY (kW) Cooling 5.4 (1.55 - 6.0) 7.2 (2.9 - 8.5) 8.0 (3.7 - 9.2)

Heating 6.6 (1.58 - 7.2) 9.0 (2.6 - 11.0) 9.4 (3.4 - 11.6) POWER CONSUMPTION Cooling 1.86 (0.37 - 2.13) 2.09 (0.72 - 2.56) 2.19 (0.81 - 2.58) incl. indoor units (kW) Heating 1.77 (0.29 - 1.85) 2.15 (0.53 - 3.05) 1.93 (0.59 - 3.23)AIRFLOW (m3/h) 2460 2630 2630NOISE dB(A) 50 48 48WEIGHT (kg) 52 69 70DIMENSIONS (mm) Width 909 900 900

Depth 330 360 360Height 640 900 900

MAX. PIPE LENGTH per indoor unit (m) 20 25 25TOTAL PIPE LENGTH (m) 30 50 70MAX. HEIGHTDIFFERENCE (m) 10 10 10CHARGE R410A* (kg) 1.75 3.5 3.5Pipe size Liquid 2 x 6 3 x 6 4 x 6Ø (mm) Gas 2 x 10 1 x 12 / 2 x 10 2 x 12 / 2 x 10ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50RUNNING CURRENT (A) Cooling 8.98 9.18 9.62

Heating 8.55 9.44 8.48

REMARK: The Multi-Split Systems run either cooling or heating mode.At least two indoor units have to be connected.Possible combinations on page 21, 22 and 23.

* Factory charged for max. pipe lengths please view page 25

Page 21: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

21

COMBINATION EXAMPLESMXZ-A18WV -Please refer to the following table forpermitted combinations

MXZ Inverter Multi-SplitSystems Cooling/Heating

Series

MXZ-A18WV• Wall mounted systems: MSC-A07/09/12YV• Floor or ceiling mounted systems: MCFH-A12WV• Ceiling concealed systems: SEZ-A12AR• In-ceiling cassette systems: SLZ-A09/12AR, SLP-2AL (Grille)

Combination Mode Capacity (kW)Model A B TOTAL

07 Cooling / HEATING 2.30 / 3.30 –/– 2.3 (0.90 - 2.95) / 3.30 (0.90 - 4.00)09 Cooling / HEATING 2.50 / 3.60 –/– 2.5 (0.90 - 3.30) / 3.60 (0.90 - 4.50)12 Cooling / HEATING 3.40 / 4.00 –/– 3.4 (0.90 - 4.00) / 4.00 (0.90 - 4.80)07+07 Cooling / HEATING 2.30 / 3.05 2.30 / 3.05 4.6 (1.49 - 5.30) / 6.10 (1.53 - 6.70)07+09 Cooling / HEATING 2.30/ 2.97 2.50 / 3.23 4.8 (1.49 - 5.40) / 6.20 (1.53 - 6.80)07+12 Cooling / HEATING 2.02 / 2.62 2.98 / 3.88 5.0 (1.51 - 5.60) / 6.50 (1.55 - 7.00)09+09 Cooling / HEATING 2.50 / 3.25 2.50 / 3.25 5.0 (1.51 - 5.55) / 6.50 (1.55 - 7.00)09+12 Cooling / HEATING 2.20 / 2.78 3.10 / 3.77 5.3 (1.53 - 5.80) / 6.55 (1.56 - 7.10)12 +12 Cooling / HEATING 2.65 / 3.30 2.65 / 3.30 5.4 (1.55 - 6.00) / 6.60 (1.58 - 7.20)

MXZ-A18WV

MCFH-A12WV

MXZ-A18WV

SLZ-A09/12ARSLP-2AL (Grille)

MSC-A12YV

SEZ-A12AR

Page 22: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

22

MXZ-A26WV • Wall mounted systems: MSC-A07/09/12YV, MSH-A18/24WV• Floor or ceiling mounted systems: MCFH-A12/18/24WV• Ceiling concealed systems: SEZ-A12/18/24AR• In-ceiling cassette systems: SLZ-A09/12/18AR (grille SLP-2AL)

Kombination Model Mode Capacity (kW)

A B C Total7 Cooling/Heating 2.3 / 3.3 2.3 (1.4-3.0) / 3.3 (1.2-4.2)9 Cooling/Heating 2.5 / 3.6 2.5 (1.4-3.3) / 3.6 (1.2-4.5)12 Cooling/Heating 3.4 / 4.0 3.4 (1.5-4.3) / 4.0 (1.2-4.8)18 Cooling/Heating 5.0 / 7.2 5.0 (1.6-5.6) / 7.2 (1.4-8.2)24 Cooling/Heating 6.0 / 7.9 6.0 (1.6-6.6) / 7.9 (1.4-8.6)07+07 Cooling/Heating 2.3 / 3.3 2.3 / 3.3 4.6 (2.0-5.4) / 6.6 (1.8-7.2)07+09 Cooling/Heating 2.1 / 3.02 2.7 / 3.88 4.8 (2.0-5.8) / 6.9 (1.8-8.7)07+12 Cooling/Heating 2.1 / 2.69 3.6 / 4.61 5.7 (2.0-6.6) / 7.3 (1.8-9.2)07+18 Cooling/Heating 2.01 / 2.49 5.18/ 6.41 7.2 (2.0-7.7) / 8.9 (1.8-9.9)07+24 Cooling/Heating 1.62 / 2.03 5.57 / 6.97 7.2 (2.0-8.0) / 9.0 (1.8-9.9)09+09 Cooling/Heating 2.5 / 3.6 2.5 / 3.6 5.0 (2.0-6.2) / 7.2 (1.8-9.1)09+12 Cooling/Heating 2.52 / 3.26 3.37 / 4.34 5.9 (2.0-7.3) / 7.6 (1.8-9.5)09+18 Cooling/Heating 2.4 / 3.0 4.8 / 6.0 7.2 (2.0-8.5) / 9.0 (1.8-10.1)09+24 Cooling/Heating 1.96 / 2.45 5.23 / 6.55 7.2 (2.0-8.5) / 9.0 (1.8-10.1)12+12 Cooling/Heating 3.4 / 4.0 3.4 / 4.0 6.8 (2.0-8.5) / 8.0 (1.8-9.8)12+18 Cooling/Heating 2.88 / 3.6 4.32 / 5.4 7.2 (2.0-8.5) / 9.0 (1.8-10.5)12+24 Cooling/Heating 2.4 / 3.0 4.8 / 6.0 7.2 (2.0-8.5) / 9.0 (1.8-10.5)18+18 Cooling/Heating 3.6 / 4.5 3.6 / 4.5 7.2 (2.1-8.5) / 9.0 (1.9-11.0)18+24 Cooling/Heating 3.08 / 3.86 4.11 / 5.14 7.2 (2.1-8.5) / 9.0 (1.9-11.0)07+07+07 Cooling/Heating 2.3 / 2.9 2.3 / 2.9 2.3 / 2.9 6.9 (2.9-8.1) / 8.7 (2.6-10.6)07+07+09 Cooling/Heating 2.16 / 2.67 2.16 / 2.67 2.77 / 3.44 7.1 (2.9-8.5) / 8.8 (2.6-11.0)07+07+12 Cooling/Heating 1.93 / 2.42 1.93 / 2.42 3.32 / 4.15 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+07+18 Cooling/Heating 1.58 / 1.96 1.58 / 1.96 4.05 / 5.06 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+07+24 Cooling/Heating 1.32 / 1.65 1.32 / 1.65 4.55 / 5.68 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+09+09 Cooling/Heating 2.01 / 2.52 2.59 / 3.24 2.59 / 3.24 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+09+12 Cooling/Heating 1.8 / 2.25 2.31 / 2.89 3.09 / 3.85 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+09+18 Cooling/Heating 1.48 / 1.85 1.9 / 2.38 3.81 / 4.76 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+09+24 Cooling/Heating 1.26 / 1.57 1.62 / 2.02 4.32 / 5.4 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+12+12 Cooling/Heating 1.62 / 2.03 2.79 / 3.48 2.79 / 3.48 7.2 (2.9-8.5) / 9.0 (2.6-11.0)07+12+18 Cooling/Heating 1.36 / 1.7 2.33 / 2.91 3.5 / 4.37 7.2 (2.9-8.5) / 9.0 (2.7-11.0)07+12+24 Cooling/Heating 1.17 / 1.46 2.0 / 2.51 4.01 / 5.02 7.2 (2.9-8.5) / 9.0 (2.7-11.0)07+18+18 Cooling/Heating 1.17 / 1.46 3.01 / 3.76 3.01 / 3.76 7.2 (2.9-8.5) / 9.0 (2.7-11.0)07+18+24 Cooling/Heating 1.02 / 1.28 2.64 / 3.0 3.52 / 4.4 7.2 (2.9-8.5) / 9.0 (2.7-11.0)09+09+09 Cooling/Heating 2.36 / 3.0 2.36 / 3.0 2.36 / 3.0 7.2 (2.9-8.5) / 9.0 (2.6-11.0)09+09+12 Cooling/Heating 2.16 / 2.7 2.16 / 2.7 2.89 / 3.6 7.2 (2.9-8.5) / 9.0 (2.6-11.0)09+09+18 Cooling/Heating 1.8 / 2.25 1.8 / 2.25 3.6 / 4.5 7.2 (2.9-8.5) / 9.0 (2.6-11.0)09+09+24 Cooling/Heating 1.45 / 1.92 1.45 / 1.92 4.11 / 5.14 7.2 (2.9-8.5) / 9.0 (2.6-11.0)09+12+12 Cooling/Heating 1.97 / 2.45 2.61 / 3.27 2.61 / 3.27 7.2 (2.9-8.5) / 9.0 (2.6-11.0)09+12+18 Cooling/Heating 1.66 / 2.07 2.21 / 2.76 3.32 / 4.15 7.2 (2.9-8.5) / 9.0 (2.7-11.0)09+12+24 Cooling/Heating 1.44 / 1.8 1.92 / 2.4 3.84 / 4.8 7.2 (2.9-8.5) / 9.0 (2.7-11.0)09+18+18 Cooling/Heating 1.44 / 1.8 2.88 / 3.6 2.88 / 3.6 7.2 (2.9-8.5) / 9.0 (2.7-11.0)09+18+24 Cooling/Heating 1.27 / 1.58 2.54 / 3.17 3.38 / 4.23 7.2 (2.9-8.5) / 9.0 (2.7-11.0)12+12+12 Cooling/Heating 2.4 / 3.0 2.4 / 3.0 2.4 / 3.0 7.2 (2.9-8.5) / 9.0 (2.6-11.0)12+12+18 Cooling/Heating 2.05 / 2.57 2.05 / 2.57 3.08 / 3.85 7.2 (2.9-8.5) / 9.0 (2.7-11.0)12+12+24 Cooling/Heating 1.8 / 2.25 1.8 / 2.25 3.6 / 4.5 7.2 (2.9-8.5) / 9.0 (2.7-11.0)12+18+18 Cooling/Heating 1.8 / 2.25 2.7 / 3.37 2.7 / 3.37 7.2 (2.9-8.5) / 9.0 (2.7-11.0)12+18+24 Cooling/Heating 1.6 / 2.0 2.4 / 3.0 3.2 / 4.0 7.2 (2.9-8.5) / 9.0 (2.7-11.0)

Page 23: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

2323

MXZ-A32WV • Wall mounted systems: MSC-A07/09/12YV, MSH-A18/24WV• Floor or ceiling mounted systems: MCFH-A12/18/24WV• Ceiling concealed systems: SEZ-A12/18/24AR• In-ceiling cassette systems: SLZ-A09/12/18AR (grille SLP-2AL)

Combination Model Model Capacity (kW)

Cooling/Heating A B C D Total7 Cooling/Heating 2.3 / 3.3 2.3 (1.4-3.0) / 3.3 (1.2-4.2)9 Cooling/Heating 2.5 / 3.6 2.5 (1.4-3.3) / 3.6 (1.2-4.5)12 Cooling/Heating 3.4 / 4.0 3.4 (1.5-4.3) / 4.0 (1.2-4.8)18 Cooling/Heating 5.0 / 7.2 5.0 (1.6-5.6) / 7.2 (1.4-8.4)24 Cooling/Heating 6.0 / 7.9 6.0 (1.6-6.6) / 7.9 (1.4-8.6)07+07 Cooling/Heating 2.3 / 3.3 2.3 / 3.3 4.6 (2.0-5.4) / 6.6 (1.8-7.2)07+09 Cooling/Heating 2.1 / 3.02 2.7 / 3.88 4.8 (2.0-5.8) / 6.9 (1.8-8.7)07+12 Cooling/Heating 2.1 / 2.69 3.6 / 4.61 5.7 (2.0-6.6) / 7.3 (1.8-9.2)07+18 Cooling/Heating 2.04 / 2.49 5.25 / 6.41 7.3 (2.0-7.7) / 8.9 (1.8-9.9)07+24 Cooling/Heating 1.75 / 2.12 6.0 / 7.28 7.75 (2.0-8.0) / 9.4 (1.8-9.9)09+09 Cooling/Heating 2.5 / 3.6 2.5 / 3.6 5.0 (2.0-6.2) / 7.2 (1.8-9.1)09+12 Cooling/Heating 2.52 / 3.26 3.37 / 4.34 5.9 (2.0-7.3) / 7.6 (1.8-9.5)09+18 Cooling/Heating 2.5 / 3.0 5.0 / 6.0 7.5 (2.0-8.5) / 9.0 (1.8-10.1)09+24 Cooling/Heating 2.11 / 2.56 5.64 / 6.84 7.75 (2.0-8.5) / 9.4 (1.8-10.1)12+12 Cooling/Heating 3.4 / 4.0 3.4 / 4.0 6.8 (2.0-8.8) / 8.0 (1.8-9.8)12+18 Cooling/Heating 3.1 / 3.76 4.65 / 5.64 7.75 (2.0-8.8) / 9.4 (1.8-10.5)12+24 Cooling/Heating 2.61 / 3.13 5.24 / 6.27 7.85 (2.0-8.8) / 9.4 (1.8-10.5)18+18 Cooling/Heating 3.95 / 4.7 3.95 / 4.7 7.9 (2.1-8.8) / 9.4 (1.9-11.2)18+24 Cooling/Heating 3.42 / 4.03 4.57 / 5.37 8.0 (2.1-8.8) / 9.4 (1.9-11.2)24+24 Cooling/Heating 4.0 / 4.7 4.0 / 4.7 8.0 (2.1-8.8) / 9.4 (1.9-11.2)07+07+07 Cooling/Heating 2.3 /2.9 2.3 /2.9 2.3 /2.9 6.9 (2.9-8.1) / 8.7 (2.6-10.6)07+07+09 Cooling/Heating 2.16 / 2.67 2.16 / 2.67 2.77 / 3.44 7.1 (2.9-8.6) / 8.8 (2.6-11.1)07+07+12 Cooling/Heating 2.07 / 2.53 2.07 / 2.53 3.55 / 4.33 7.7 (2.9-9.0) / 9.4 (2.6-11.6)07+07+18 Cooling/Heating 1.72 / 2.05 1.72 / 2.05 4.41 / 5.28 7.85 (2.9-9.0) / 9.4 (2.6-11.6)07+07+24 Cooling/Heating 1.46 / 1.73 1.46 / 1.73 5.03 / 5.93 7.95 (2.9-9.0) / 9.4 (2.6-11.6)07+09+09 Cooling/Heating 2.04 / 2.49 2.62 / 3.2 2.62 / 3.2 7.3 (2.9-8.9) / 8.9 (2.6-11.6)07+09+12 Cooling/Heating 1.93 / 2.35 2.49 / 3.02 3.33 / 4.02 7.75 (2.9-9.0) / 9.4 (2.6-11.6)07+09+18 Cooling/Heating 1.62 / 1.93 2.09 / 2.48 4.18 / 4.97 7.9 (2.9-9.0) / 9.4 (2.6-11.6)07+09+24 Cooling/Heating 1.4 / 1.64 1.8 / 2.11 4.8 / 5.64 8.0 (2.9-9.0) / 9.4 (2.6-11.6)07+12+12 Cooling/Heating 1.77 / 2.12 3.04 / 3.63 3.04 / 3.63 7.85 (2.9-9.0) / 9.4 (2.6-11.6)07+12+18 Cooling/Heating 1.49 / 1.77 2.56 / 3.04 3.84 / 4.57 7.9 (2.9-9.0) / 9.4 (2.7-11.6)07+12+24 Cooling/Heating 1.3 / 1.53 2.23 / 2.62 4.46 / 5.24 8.0 (2.9-9.0) / 9.4 (2.7-11.6)07+18+18 Cooling/Heating 1.3 / 1.53 3.34 / 3.93 3.34 / 3.93 8.0 (2.9-9.0) / 9.4 (2.7-11.6)07+18+24 Cooling/Heating 1.14 / 1.34 2.93 / 3.45 3.91 / 4.6 8.0 (2.9-9.0) / 9.4 (2.7-11.6)09+09+09 Cooling/Heating 2.36 / 3.0 2.36 / 3.0 2.36 / 3.0 7.1 (2.9-9.0) / 9.0 (2.6-11.6)09+09+12 Cooling/Heating 2.32 / 2.82 2.32 / 2.82 3.11 / 3.76 7.75 (2.9-9.0) / 9.4 (2.6-11.6)09+09+18 Cooling/Heating 1.97 / 2.35 1.97 / 2.35 3.95 / 4.7 7.9 (2.9-9.0) / 9.4 (2.6-11.6)09+09+24 Cooling/Heating 1.71 / 2.01 1.71 / 2.01 4.57 / 5.37 8.0 (2.9-9.0) / 9.4 (2.6-11.6)09+12+12 Cooling/Heating 2.15 / 2.56 2.85 / 3.41 2.85 / 3.41 7.85 (2.9-9.0) / 9.4 (2.6-11.6)09+12+18 Cooling/Heating 1.84 / 2.16 2.46 / 2.89 3.69 / 4.33 8.0 (2.9-9.0) / 9.4 (2.7-11.6)09+12+24 Cooling/Heating 1.6 / 1.88 2.13 / 2.5 4.26 / 5.01 8.0 (2.9-9.0) / 9.4 (2.7-11.6)09+18+18 Cooling/Heating 1.6 / 1.88 3.2 / 3.76 3.2 / 3.76 8.0 (2.9-9.0) / 9.4 (2.7-11.6)09+18+24 Cooling/Heating 1.41 / 1.65 2.82 / 3.31 3.76 / 4.42 8.0 (2.9-9.0) / 9.4 (2.7-11.6)12+12+12 Cooling/Heating 2.65 / 3.13 2.65 / 3.13 2.65 / 3.13 7.95 (2.9-9.0) / 9.4 (2.6-11.6)12+12+18 Cooling/Heating 2.28 / 2.68 2.28 / 2.68 3.42 / 4.02 8.0 (2.9-9.0) / 9.4 (2.7-11.6)12+12+24 Cooling/Heating 2.0 / 2.35 2.0 / 2.35 4.0 / 4.7 8.0 (2.9-9.0) / 9.4 (2.7-11.6)12+18+18 Cooling/Heating 2.0 / 2.35 3.0 / 3.52 3.0 / 3.52 8.0 (2.9-9.0) / 9.4 (2.7-11.6)12+18+24 Cooling/Heating 1.77 / 2.08 2.66 / 3.13 3.55 / 4.17 8.0 (2.9-9.0) / 9.4 (2.7-11.6)07+07+07+07 Cooling/Heating 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 1.95 / 2.35 7.8 (3.7-9.2) / 9.4 (3.4-11.6)07+07+07+09 Cooling/Heating 1.83 / 2.19 1.83 / 2.19 1.83 / 2.19 2.36 / 2.82 7.8 (3.7-9.2) / 9.4 (3.4-11.6)07+07+07+12 Cooling/Heating 1.68 / 1.99 1.68 / 1.99 1.68 / 1.99 2.91 / 3.41 7.95 (3.7-9.2) / 9.4 (3.4-11.6)07+07+07+18 Cooling/Heating 1.43 / 1.68 1.43 / 1.68 1.43 / 1.68 3.69 / 4.33 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+07+24 Cooling/Heating 1.24 / 1.46 1.24 / 1.46 1.24 / 1.46 4.26 / 5.01 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+09+09 Cooling/Heating 1.72 / 2.05 1.72 / 2.05 2.2 / 2.64 2.2 / 2.64 7.85 (3.7-9.2) / 9.4 (3.5-11.6)07+07+09+12 Cooling/Heating 1.59 / 1.88 1.59 / 1.88 2.04 / 2.41 2.72 / 3.22 7.95 (3.7-9.2) / 9.4 (3.4-11.6)07+07+09+18 Cooling/Heating 1.36 / 1.6 1.36 / 1.6 1.75 / 2.06 3.51 / 4.12 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+09+24 Cooling/Heating 1.19 / 1.4 1.19 / 1.4 1.53 / 1.8 4.08 / 4.8 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+12+12 Cooling/Heating 1.47 / 1.73 1.47 / 1.73 2.52 / 2.96 2.52 / 2.96 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+12+18 Cooling/Heating 1.27 / 1.49 1.27 / 1.49 2.18 / 2.56 3.27 / 3.84 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+12+24 Cooling/Heating 1.12 / 1.31 1.12 / 1.31 1.92 / 2.25 3.84 / 4.51 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+07+18+18 Cooling/Heating 1.12 / 1.31 1.12 / 1.31 2.88 / 3.38 2.88 / 3.38 8.0 (3.7-9.2) / 9.4 (3.4-11.6)07+09+09+09 Cooling/Heating 1.62 / 1.93 2.09 / 2.48 2.09 / 2.48 2.09 / 2.48 7.9 (3.7-9.2) / 9.4 (3.4-11.6)07+09+09+12 Cooling/Heating 1.5 / 1.77 1.93 / 2.28 1.93 / 2.28 2.59 / 3.04 7.95 (3.7-9.2) / 9.4 (3.4-11.6)07+09+09+18 Cooling/Heating 1.3 / 1.53 1.67 / 1.96 1.67 / 1.96 3.34 / 3.93 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+09+09+24 Cooling/Heating 1.14 / 1.34 1.46 / 1.72 1.46 / 1.72 3.91 / 4.60 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+09+12+12 Cooling/Heating 1.4 / 1.64 1.8 / 2.11 2.4 / 2.82 2.4 / 2.82 8.0 (3.7-9.2) / 9.4 (3.4-11.6)07+09+12+18 Cooling/Heating 1.21 / 1.43 1.56 / 1.83 2.08 / 2.45 3.13 / 3.67 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+09+12+24 Cooling/Heating 1.07 / 1.26 1.38 / 1.62 1.84 / 2.16 3.69 / 4.33 8.0 (3.7-9.2) / 9.4 (3.5-11.6)07+12+12+12 Cooling/Heating 1.3 / 1.53 2.23 / 2.62 2.23 / 2.62 2.23 / 2.62 8.0 (3.7-9.2) / 9.4 (3.4-11.6)07+12+12+18 Cooling/Heating 1.14 / 1.34 1.95 / 2.3 1.95 / 2.3 2.93 / 3.45 8.0 (3.7-9.2) / 9.4 (3.4-11.6)09+09+09+09 Cooling/Heating 1.97 / 2.35 1.97 / 2.35 1.97 / 2.35 1.97 / 2.35 7.9 (3.7-9.2) / 9.4 (3.4-11.6)09+09+09+12 Cooling/Heating 1.84 / 2.16 1.84 / 2.16 1.84 / 2.16 2.46 / 2.89 8.0 (3.7-9.2) / 9.4 (3.4-11.6)09+09+09+18 Cooling/Heating 1.6 / 1.88 1.6 / 1.88 1.6 / 1.88 3.2 / 3.76 8.0 (3.7-9.2) / 9.4 (3.5-11.6)09+09+09+24 Cooling/Heating 1.41 / 1.65 1.41 / 1.65 1.41 / 1.65 3.76 / 4.42 8.0 (3.7-9.2) / 9.4 (3.5-11.6)09+09+12+12 Cooling/Heating 1.56 / 1.83 1.75 / 2.06 2.34 / 2.75 2.34 / 2.75 8.0 (3.7-9.2) / 9.4 (3.4-11.6)09+09+12+18 Cooling/Heating 1.5 / 1.76 1.5 / 1.76 2.0 / 2.35 3.0 / 3.52 8.0 (3.7-9.2) / 9.4 (3.5-11.6)09+12+12+12 Cooling/Heating 1.6 / 1.88 2.13 / 2.5 2.13 / 2.5 2.13 / 2.5 8.0 (3.7-9.2) / 9.4 (3.4-11.6)12+12+12+12 Cooling/Heating 2.0 / 2.35 2.0 / 2.35 2.0 / 2.35 2.0 / 2.35 8.0 (3.7-9.2) / 9.4 (3.4-11.6)

Page 24: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

24

AccessoriesSeries

AIR CLEANING FILTERMODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1300FT 10 MSC-A07/09/12YV

MSZ-A09/12YVMAC-1700FT 10 MS(H)-A18/24/30WV MAC-1200FT 10 MCF/MCFH

DEODORISING FILTERMODEL REFERENCE QUANTITY APPLICABLE MODELSMAC-1700DF 10 MCF/MCFH

QUICK CLEAN KITMODEL REFERENCE QUANTITY APPLICABLE MODELSMAC-093SS-E1 1 MSZ-A09/12YV

OUTDOOR UNITS with R410A• Mostly factory charged to 7 m pipe length (one-way).

• Please view the required refrigerant charge for other pipe lengths inthe following table.

MU-A07/09/12/18/24/30YV/WVOUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 7 m 10 m 15 m 20 m 25 m 30 mMU-A07YV 0.600 0.660 0.760 0.860 – –MU-A09YV 0.600 0.660 0.760 0.860 – –MU-A12YV 0.750 0.810 0.910 1.010 1.110 –MU-A18WV 1.400 1.460 1.560 1.660 1.760 –MU-A24WV 1.900 1.960 2.060 2.160 2.260 –MU-A30WV 2.300 2.465 2.740 3.015 3.290 3.465

MUH-A07/09/12/18/24/30YV/WVOUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUH-A07YV 0.620 0.680 0.780 0.880 – –MUH-A09YV 1.000 1.060 1.160 1.260 – –MUH-A12YV 1.000 1.060 1.160 1.260 1.360 –MUH-A18WV 1.750 1.810 1.910 2.010 2.110 –MUH-A24WV 2.150 2.210 2.310 2.410 2.510 –MUH-A30WV 2.300 2.465 2.740 3.015 3.290 3.565

MUCFH-A18/24WVOUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 7 m 10 m 15 m 20 m 25 m MUCFH-A18WV 1.850 1.910 2.010 2.110 2.210MUCFH-A24WV 2.200 2.260 2.360 2.460 2.560

Refrigerant ChargeSeries

Page 25: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

2525

Refrigerant ChargeSeries

MUX-A10/19/25/20/22/26WVOUTDOOR UNITS Com- Indoor Units CHARGE (ONE-WAY) in kg(MODELS) pressor Models 7 m 10 m 15 m 20 m 25 m 30 m

MUX-A10WV 1 2 X MSC-A07YV – 0.900* 0.950 1.000 1.050 1.100MUX-A19WV 1 1 X MSC-A12YV 1.000* 1.060 1.160 – – –

1 1 X MSC-A09YV 0.800* 0.860 0.960 – – –

MUX-A25WV 1 1 X MSC-A12YV 0.950* 1.010 1.110 – – –1 1 X MSC-A12YV 0.950* 1.010 1.110 – – –

MUX-A20WV 1 1 X MSC-A09YV 0.800* 0.860 0.960 – – –1 2 X MSC-A09YV – 1.000* 1.050 1.100 1.150 1.200

MUX-A22WV 1 1 X MSC-A12YV 0.850* 0.910* 1.010 – – –1 2 X MSC-A07YV – 0.850* 0.900 0.950 1.000 1.050

MUX-A26WV 1 2 X MSC-A09YV – 1.050* 1.100 1.150 1.200 1.2501 2 X MSC-A12YV – 1.050* 1.100 1.150 1.200 1.250

* Factory charged

MUZ-A09/12/18/24/26 YVOUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 7 m 10 m 15 m 20 m 25 m 30 m MUZ-A 09 YV 0.860 0.950 1.100 1.250 – –MUZ-A 12 YV 0.960 1.050 1.200 1.350 – –MUZ-A 18 YV 1.800 1.860 1.960 2.060 2.160 2.260MUZ-A 24 YV 1.800 1.860 1.960 2.060 2.160 2.260MUZ-A 26 YV 2.000 2.165 2.265 2.365 2.465 2.565

SUZ-A09/12/18YV OUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 7 m 10 m 15 m 20 m 25 m 30 m SUZ-A 09 YV 0.860 0.950 1.100 1.250 – – SUZ-A 12 YV 0.960 1.050 1.200 1.350 – –SUZ-A 18 YV 1.800 1.860 1.960 2.060 2.160 2.260

MXZ-A18/26/32WVOUTDOOR UNITS CHARGE (ONE-WAY) in kg(MODELS) 20 m 25 m 30 m 40 m 50 m 60 m 70 m MXZ-A18WV 1.750 1.850 1.950 – – – –MXZ-A26WV – – 3.500 3.600 3.700 – –MXZ-A32WV – – 3.500 3.600 3.700 3.900 4.100

Page 26: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

26

The Mr. Slim Series offers a huge choice of componentsand configurations for a wide range of applications. The packaged air conditioners are adapted for middle-sized rooms, shops, restaurants and offices - for coolingonly or with heat pump-function. With ceiling cassettes,ceiling suspended units, wall mounted units and ceilingducted units, there is a Mr. Slim model which providesthe optimum fit for your next job.

Mr. Slim SeriesSplit- and Multi-Split Systems,R407CCooling 3.15 kW - 26.0 kW

Page 27: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

2727

COOLING ONLYPMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28PLA COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32PCA CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .36PKA WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38PSA FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

HEAT PUMP UNITS - COOLING AND HEATINGPMH 1-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44PLA/PLH COMPACT 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . .46PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48PCA/PCH CEILING SUSPENDED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONS . . . . . . . . . . . . . . . . . . . . . .52PKA/PKH WALL MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54PSA/PSH FLOORSTANDING UNITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56PEAD/PEHD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58PEH CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60

Advantages of Mr. Slim● Wide range of indoor units● Simultaneous operation of 2, 3

or 4 indoor units● Standard long-life filters● Auto change over between

cooling and heating mode● Heat pump with warm start

system● Indoor units without electrical

heater connectable to heatpump outdoor units

● A-Control makes servicing easier. Automatic switching between heating and cooling is available on heat pump units.Error codes are shown at remote controls display of indoor units.

● Wired or infrared remote controller optional

● Maintenance Tool for controland service

● All models can be interfaced toBuilding Management Systemsby Lon Works Interface

● Lossnay heat exchange ventilators connectable

● Factory charged with R407C● Winter kit as standard, cooling

up to -15°

Rating conditions Mr. SlimSeries* R407C:● Cooling

Indoor: 19°C - 35°C DB15°C - 22.5°C WB

Outdoor: -15°C - 46°C DB

● HeatingIndoor: 17°C - 28°C DBOutdoor: -11°C - 24°C DB

-12°C - 18°C WB

* For PUH-P8/10MYA other ratingconditions, please view page 61

Page 28: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

2828

● Simple installation and service,because of compact dimen-sions – installation height only230 mm

● Wired remote control● Precisely directed airflow to

prevent dirt built-up and stai-ning of ceiling tiles

● Standard long-life filter● Simple installation and easy

access drain and refrigerantpiping connections

● Factory charged with R407C● Rotary and scroll compressors● Twin, triple and quadruple

configuration possible● Standard drain pump for 600

mm height differences● External airflow prepared● 4 fan-stages for comfortable

and optimum airflow

Accessories:Optional parts on page 70 andthe following

Mr. Slim SeriesPMH Cooling Only1-Way-In-Ceiling Cassette Systems

Page 29: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

2929

PMH 1-WAY-IN-CEILING CASSETTE SYSTEMSCOOLING ONLYINDOOR UNIT PMH-P1.6 BA PMH-P2 BACAPACITY (kW) Cooling 4.4 5.4AIRFLOW (m3/h) Low 420 480

Middle 1 480 540Middle 2 540 600High 600 660

NOISE dB(A) Low 34 36High 40 42

WEIGHT incl. Grille (kg) 14/17 14/17DIMENSIONS (mm) Width 854 854Indoor unit Depth 395 395

Height* 230 230DIMENSIONS (mm) Width 1000 1000Grille Depth 470 470

Height** 30 30ELECTRICAL SUPPLY 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.29 0.29OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAAPOWER CONSUMPTION (kW) Cooling 1.6 2.3AIRFLOW (m3/h) 2700 3300

NOISE dB(A) 47 48WEIGHT (kg) 55 71DIMENSIONS (mm) Width 900 900

Depth 350 350Height 650 855

MAX. PIPE LENGTH (m) 40 40MAX. HEIGHT DIFFERENCE (m) 40 40CHARGE R407C*** (kg) 2.5 2.6PIPE SIZE Liquid 10 10ø (mm) Gas 16 16ELECTRICAL SUPPLY 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7

*** Required installation height*** Visible height of grille*** Factory charged to 20 m pipe length, optional charging please view page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz

Page 30: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

3030

● Wired remote control with 24h-timer

● Compact dimensions● Simple installation with easy

access drain and refrigerantpiping connections

● Adjustable air outlets for optimum airflow for ceilingheights up to 3.8 m

● Precisely directed airflow to prevent dirt built-up andstaining of ceiling tiles

● Rotary and scroll compressors● Factory charged with R407C● Long-life air filter● Drain pump for 500 mm height

difference

● Twin, triple, quadruple configuration possible, on page 72

Accessories:● Space panel enables installation

into ceiling void of just 258 mmdepth

● Infrared remote control● High efficiency filter and

external airflow

For detailed descriptionsplease view on page 70 and the following

Mr. Slim SeriesPLA Cooling Only4-Way-In-Ceiling Cassette Systems

Page 31: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

3131

PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLYINDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KACAPACITY (kW) Cooling 4.4 5.3 6.3AIRFLOW (m3/h) Low 780 780 840

Middle 1 840 840 900Middle 2 900 900 960High 960 960 1020

NOISE dB(A) Low 32 32 35High 37 37 39.5

WEIGHT incl. Grille (kg) 19 / 22.7 19 / 22.7 20 / 23.7DIMENSIONS (mm) Width 660 660 660Indoor unit Depth 660 660 660

Height* 298 298 298DIMENSIONS (mm) Width 760 760 760(Grille) Depth 760 760 760

Height** 30 30 30ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.64 0.65 0.61OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAAPOWER CONSUMPTION (kW) Cooling 1.8 2.4 2.6AIRFLOW (m3/h)

2700 3300 3000

NOISE dB(A) 47 48 48WEIGHT (kg) 55 71 82DIMENSIONS (mm) Width 900 900 900

Depth 350 350 350Height 650 855 855

MAX. PIPE LENGTH (m) 40 40 50MAX. HEIGHT DIFFERENCE (m) 40 40 50CHARGE R407C*** (kg) 2.5 2.6 3.1PIPE SIZE Liquid 10 10 10ø (mm) Gas 16 16 16ELECTRICAL SUPPLY(V, PHASE, Hz)

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50

RUNNING CURRENT (A) Cooling 2.5 3.7 4.5

Optional

*** Required installation height*** Visible height of grille*** Factory charged to 20 m pipe length, for further information please view page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.Outdoor units PU-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz

GRILLE-TYPE FOR WIRED REMOTE CONTROL PLP-2.5 KCGRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KLM

Page 32: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

32

● Wired remote control or infrared remote control with24h-timer

● Compact dimensions● Extremely quiet operation

noise, PLA-P3AA just 28 dB(A)● Weight reduced for PLA-P6AA

from 46 kg to only 37 kg● Great convenience due to four

fan-stages● Drain pump for 850 mm height

difference● Simple installation with easy

access drain and refrigerantpiping connections

● Adjustable air outlets for optimum airflow for ceilingheights up to 4.2 m

● Precisely directed airflow to prevent dirt built-up andstaining of ceiling tiles

● Rotary and scroll compressors● Factory charged with R407C● Long-life air filter

● Twin, triple, quadruple configuration possible, onpage 72

Accessories:● Space panel enables

installation into ceiling void of just 258 mm depth

● High efficiency filter and external airflow

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPLA Cooling Only4-Way-In-Ceiling Cassette Systems

Page 33: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

33

PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING ONLYINDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AACAPACITY (kW) Cooling 7.8 9.7 12.8 14.3AIRFLOW (m3/h) Low 900 1200 1320 1320

Middle 1 960 1380 1500 1500Middle 2 1080 1560 1680 1680High 1200 1680 1800 1800

NOISE dB(A) Low 28 33 35 37 High 34 41 43 45

WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37DIMENSIONS (mm) Width 840 840 840 840Indoor unit Depth 840 840 840 840

Height* 258 298 298 298DIMENSIONS (mm) Width 950 950 950 950(Grille) Depth 950 950 950 950

Height** 30 30 30 30ELECTRICAL SUPPLY 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, phase, Hz)RUNNING CURRENT (A) Cooling 0.81 1.25 1.43 1.6OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAAPOWER CONSUMPTION (kW) Cooling 3.4 3.7 5.0 5.9AIRFLOW (m3/h) 3000 5100 5700 6000

NOISE dB(A) 49 51 55 57WEIGHT (kg) 82 96 122 122DIMENSIONS (mm) Width 900 900 1050 1050

Depth 350 350 350 350Height 855 1260 1260 1260

MAX. PIPE LENGTH (m) 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 50 50 50 50CHARGE R407C*** (kg) 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10ø (mm) Gas 16 18 18 18ELECTRICAL SUPPLY 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0

*** Required installation height*** Visible height of grille*** Factory charged to 30 m pipe length, for further information please view page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.

GRILLE-TYPE FOR WIRED REMOTE CONTROL PLP-6 AAMGRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AALM

Page 34: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

3434

● Wired remote control with24h-timer

● Adjustable air outlets for optimum airflow for ceilingheights up to 3.5 m

● Rotary and scroll compressors● Factory charged with R407C● Long-life air filter● Great convenience due to four

fan-stages● Swing louvres with `Auto

Angle´ airflow

● Twin, triple, quadruple configuration possible, on page 72

Accessories:● High efficiency filter● Drain pump● Infrared remote control

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPCA Cooling OnlyCeiling Suspended Systems

Page 35: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

35

PCA CEILING SUSPENDED SYSTEMS COOLING ONLYINDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GACAPACITY (kW) Cooling 5.4 6.7 7.5 9.7 12.4 14.3AIRFLOW (m3/h) Low 600 840 840 1200 1620 1620

Middle 1 660 900 900 1260 1800 1800Middle 2 720 960 960 1380 1920 1920High 780 1080 1080 1500 2040 2040

NOISE dB(A) Low 37 37 37 40 41 42High 42 43 43 45 46 48

WEIGHT (kg) 27 34 34 37 43 45DIMENSIONS (mm) Width 1000 1310 1310 1310 1620 1620

Depth 680 680 680 680 680 680Height 210 210 210 270 270 270

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.43 0.55 0.55 0.7 1.1 1.1OUTDOOR UNIT PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAAPOWERCONSUMPTION (kW) Cooling 2.4 2.65 3.4 3.64 4.94 5.94AIRFLOW (m3/h)

3300 3000 3000 5100 5700 6000

NOISE dB(A) 48 48 49 51 55 57WEIGHT (kg) 71 82 82 96 122 122DIMENSIONS (mm) Width 900 900 900 900 1050 1050

Depth 350 350 350 350 350 350Height 855 855 855 1260 1260 1260

MAX. PIPE LENGTH (m) 40 50 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 50 50 50 50 50CHARGE R407C* (kg) 2.6 3.1 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10 10 10ø (mm) Gas 16 16 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 3.7 4.5 5.29 5.55 7.6 9.0

Optional

* Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 36: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

36

Mr. Slim SeriesPCA Cooling OnlyCeiling Suspended Systems For Applications InKitchens

● The established ceiling suspended system consistingof stainless steel for applica-tions in kitchens

● The special construction enables easy cleaning of thecasing and of all airflow parts

● Oil particles can be filtered 1.5times more efficient comparedto conventional types due to high performance filter (optional)

● On the rear panel roundknockout opening (Ø 200 mm)allows more comfort by supplying fresh air

● Rotary and scroll compressors

● Factory charged with R407C● Wired remote control with

24h-timer● Twin configuration possible,

on page 72

Accessories:● Oil mist filter (12 pcs.)PAC-SG 38 KF-E

For detailed descriptionsplease view on page 70 andthe following

Page 37: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

3737

PCA CEILING SUSPENDED SYSTEMSCOOLING ONLYINDOOR UNIT PCA-P3HA PCA-P5HACAPACITY (kW) Cooling 7.5 13.0AIRFLOW (m3/h) Low 1020 1800

High 1140 2280 NOISE dB(A) Low 34 44

High 38 50 WEIGHT (kg) 41 56 DIMENSIONS (mm) Width 1136 1520

Depth 650 650 Height 280 280

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.55 1.1

OUTDOOR UNIT PU-P3YGAA PU-P5YGAA

POWER CONSUMPTION (kW)

Cooling 3.36 4.90

AIRFLOW (m3/h) 3000 5700NOISE dB(A) 49 55WEIGHT (kg) 82 122DIMENSIONS (mm) Width 900 1050

Depth 350 350 Height 855 1260

MAX. PIPE LENGTH (m) 50 50MAX. HEIGHT DIFFERENCE (m) 50 50CHARGE R407C* (kg) 3.3 4.6PIPE SIZE Liquid 10 10 ø (mm) Gas 16 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 (V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.29 7.60

* Factory charged to 30 m pipe length, for further information please view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 38: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

38

● Infrared remote control with24h-timer

● Slim compact units for wallmounting

● Simple installation with easyaccess drain and refrigerantpiping connections

● Rotary and scroll compressors● Factory charged with R407C● Easily removable long-life air

filter● PKA-P1.6/2 GAL with four

fan-stages

● Swing louvres with “Auto Angle” airflow

● Twin, triple, quadruple configuration possible, on page 72

Accessories:● Drain pump● Wired remote control

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPKA Cooling OnlyWall Mounted Systems

Page 39: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

39

PKA WALL MOUNTED SYSTEMS COOLING ONLYINDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FALCAPACITY (kW) Cooling 4.5 5.6 6.5 7.9 9.5AIRFLOW (m3/h) Low 540 540 900 900 1320

Middle 1 600 600 – – –Middle 2 660 660 – – –High 720 720 1200 1200 1680

NOISE dB(A) Low 36 36 39 39 41High 43 43 45 45 46

WEIGHT (kg) 16 16 24 24 28DIMENSIONS (mm) Width 990 990 1400 1400 1680

Depth 235 235 235 235 235Height 340 340 340 340 340

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.33 0.33 0.43 0.43 0.52OUTDOOR UNIT PU-P1.6 YGAA PU-P2 YGAA PU-P2.5 YGAA PU-P3 YGAA PU-P4 YGAAPOWER CONSUMPTION (kW) Cooling 1.7 2.4 2.7 3.4 3.6AIRFLOW (m3/h)

2700 3300 3000 3000 5100

NOISE dB(A) 47 48 48 49 51WEIGHT (kg) 55 71 82 82 96DIMENSIONS (mm) Width 900 900 900 900 900

Depth 350 350 350 350 350Height 650 855 855 855 1260

MAX. PIPE LENGTH (m) 40 40 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50CHARGE R407C* (kg) 2.5 2.6 3.1 3.3 4.0PIPE SIZE Liquid 10 10 10 10 10ø (mm) Gas 16 16 16 16 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 5.3 5.6

Optional

* Factory charged to 20 m pipe length, PU-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 40: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

40

Mr. Slim SeriesPSA Cooling OnlyFloorstanding units

● Function panel case integrated● 24h-timer● Simple installation with easy

access drain and refrigerantpiping connections

● Rotary and scroll compressors● Factory charged with R407C

● Standard long-life filter● Twin and triple configuration

possible, on page 72

Accessories:Optional parts on page 70 andthe following

Page 41: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

41

PSA FLOORSTANDING UNITS COOLING ONLYINDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GACAPACITY (kW) Cooling 7.7 9.7 12.4 14.0AIRFLOW (m3/h) Low 900 1440 1560 1620

High 1080 1860 1920 2100NOISE dB(A) Low 40 44 46 47

High 45 49 51 52WEIGHT (kg) 43 51 51 53DIMENSIONS (mm) Width 600 600 600 600

Depth 270 350 350 350Height 1900 1900 1900 1900

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.68 1.1 1.26 1.62OUTDOOR UNIT PU-P3 YGAA PU-P4 YGAA PU-P5 YGAA PU-P6 YGAAPOWER CONSUMPTION (kW) Cooling 3.4 3.8 5.0 5.8AIRFLOW (m3/h)

3000 5100 5700 6000

NOISE dB(A) 49 51 55 57WEIGHT (kg) 82 96 122 122DIMENSIONS (mm) Width 900 900 1050 1050

Depth 350 350 350 350Height 855 1260 1260 1260

MAX. PIPE LENGTH (m) 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 50 50 50 50CHARGE R407C* (kg) 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10ø (mm) Gas 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0

* Factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m above.

Page 42: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

42

● Wired remote control with 24h-timer

● Simple installation with easyaccess drain and refrigerantpiping connections

● PEAD-P1.6/2/2.5 EA airflowvariable - draw in from theback or underside

● Rotary and scroll compressors● Factory charged with R407C● Standard long-life filter

● Twin, triple, quadruple configuration possible, on page 72

Accessories:● Drain pump● Fan motor (external static

pressure 130 Pa)

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPEAD Cooling OnlyAbove-Ceiling Concealed Ducted Systems

Page 43: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

43

PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING ONLYINDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EACAPACITY (kW) Cooling 4.5 5.6 6.7 7.7 9.7 12.3 14.1AIRFLOW (m3/h) Low 660 810 1020 1200 1620 2010 2190

High 840 1020 1260 1500 2040 2520 2760 EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**)NOISE dB(A) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47)

High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53)WEIGHT (kg) 33 33 42 44 62 65 70DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715

Depth 700 700 700 740 740 740 740Height 295 295 295 325 325 325 325

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.55 0.61 0.7 1.7 2.6 2.7 2.8OUTDOOR UNIT PU-P1.6YGAA PU-P2YGAA PU-P2.5YGAA PU-P3YGAA PU-P4YGAA PU-P5YGAA PU-P6YGAAPOWERCONSUMPTION (kW) Cooling 1.8 2.4 2.7 3.4 3.9 4.9 5.9AIRFLOW (m3/h) 2700 3300 3000 3000 5100 5700 6000NOISE dB(A) 47 48 48 49 51 55 57WEIGHT (kg) 55 71 82 82 96 122 122DIMENSIONS (mm) Width 900 900 900 900 900 1050 1050

Depth 350 350 350 350 350 350 350Height 650 855 855 855 1260 1260 1260

MAX. PIPE LENGTH (m) 40 40 50 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 50 50CHARGE R407C* (kg) 2.5 2.6 3.1 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10 10 10 10ø (mm) Gas 16 16 16 16 18 18 18ELECTRICAL SUPPLY 380-415, 3. 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7 4.5 5.3 5.6 7.6 9.0

** Factory charged to 20 m pipe length, PU-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73** Fan motor optional on page 70The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 44: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

44

● Simple installation and servicebecause of compact dimen-sions - installation height only230 mm

● Wired remote control with 24h-timer

● Quiet operation - only 29 dB(A)at PMH-P1 BA

● Precisely directed airflow to prevent dirt built-up andstaining of ceiling tiles

● Standard long-life filter● Easy access drain and

refrigerant piping connections● Factory charged with R407C● Rotary and scroll compressors● Drain pump for 600 mm height

difference● External airflow prepared● 4 fan-stages for comfortable

and optimum airflow

Accessories:Optional parts on page 70 andthe following

Mr. Slim SeriesPMH Cooling / Heating1-Way-In-Ceiling Cassette Systems

Page 45: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

45

PMH 1-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATINGINDOOR UNIT PMH-P1 BA PMH-P1.6 BA PMH-P2 BACAPACITY (kW) Cooling 3.15 4.4 5.4

Heating 3.4 5.0 6.25AIRFLOW (m3/h) Low 378 420 480

Middle 1 408 480 540Middle 2 456 540 600High 540 600 660

NOISE dB(A) Low 29 34 36High 35 40 42

WEIGHT incl. Grille (kg) 14/17 14/17 14/17DIMENSIONS (mm) Width 854 854 854Indoor unit Depth 395 395 395

Height* 230 230 230DIMENSIONS (mm) Width 1000 1000 1000Grille Depth 470 470 470

Height** 30 30 30ELECTRICAL SUPPLY 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.19 0.29 0.29

Heating 0.19 0.29 0.29OUTDOOR UNIT PUH-P1 VGAA PUH-P1.6 YGAA PUH-P2 YGAAPOWER Cooling 1.15 1.6 2.3CONSUMPTION (kW) Heating 1.06 1.7 2.4AIRFLOW (m3/h) 2700 2700 3300

NOISE dB(A) 46 47 48WEIGHT (kg) 50 55 71DIMENSIONS (mm) Width 900 900 900

Depth 350 350 350Height 650 650 855

MAX. PIPE LENGTH (m) 30 40 40MAX. HEIGHT DIFFERENCE (m) 30 40 40CHARGE R407C*** (kg) 1.7 2.5 2.6PIPE SIZE Liquid 6 10 10ø (mm) Gas 12 16 16ELECTRICAL SUPPLY 220-240, 1, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 4.9 2.5 3.7

Heating 4.5 2.6 3.8

*** Required installation height*** Visible installation height*** Factory charged to 20 m pipe length, for further information please view page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz

GRILLE-TYPE FOR WIRED REMOTE CONTROL PMP-40 BM

Page 46: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

46

● Wired remote control with24h-timer

● PLH units with additionalelectrical heating for a warm start and to increasecapacity of heat pump

● 4 fan-stages for best comfort● Precisely directed airflow to

prevent dirt built-up andstaining of ceiling tiles

● Adjustable air outlets for optimum airflow for ceilingheights up to 3.8 m

● Standard long-life filter● Simple installation with easy

access drain and refrigerantpiping connections

● Rotary and scroll compressors

● Factory charged with R407C

● Drain pump for 500 mm heightdifference

● Twin, triple, quadruple configuration possible, on page 72

Accessories: ● Space panel enables

installation into ceiling void of just 258 mm depth

● Infrared remote control● High efficiency filter and

external airflow

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPLA Cooling / HeatingPLH Cooling / Heating4-Way-In-Ceiling Cassette Systems

Page 47: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

47

PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATINGINDOOR UNIT PLA-P1.6 KA PLA-P2 KA PLA-P2.5 KAINDOOR UNIT WITH ELECTRICAL HEATING PLH-P1.6 KAH PLH-P2 KAH PLH-P2.5 KAHCAPACITY (kW) Cooling 4.4 5.3 6.3

Heating* 5.0 (6.4) 6.0 (7.4) 7.4 (9.5)AIRFLOW (m3/h) Low 780 780 840

Middle 1 840 840 900Middle 2 900 900 960High 960 960 1020

NOISE dB(A) Low 32 32 35High 37 37 39.5

WEIGHT PLA incl. Grille (kg) 19 / 22.7 19 / 22.7 20 / 23.7WEIGHT PLH incl. Grille (kg) 20 / 23.7 20 / 23.7 21 / 24.7DIMENSIONS (mm) Width 660 660 660Indoor unit Depth 660 660 660

Height** 298 298 298DIMENSIONS (mm) Width 760 760 760Grille Depth 760 760 760

Height*** 30 30 30ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.64 0.65 0.61

Heating* 0.45 (5.83) 0.45 (5.83) 0.45 (8.75)OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAAPOWER CONSUMPTION (kW) Cooling 1.8 2.4 2.6

Heating* 1.9 (3.3) 2.4 (3.8) 2.6 (4.7)AIRFLOW (m3/h) 2700 3300 3000

NOISE dB(A) 47 48 48WEIGHT (kg) 55 71 82DIMENSIONS (mm) Width 900 900 900

Depth 350 350 350Height 650 855 855

MAX. PIPE LENGTH (m) 40 40 50MAX. HEIGHT DIFFERENCE (m) 40 40 50CHARGE R407C**** (kg) 2.5 2.6 3.1PIPE SIZE Liquid 10 10 10ø (mm) Gas 16 16 16ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7 4.5

Heating 2.6 3.8 4.3

Optional

**** Values given in brackets incl. additional electrical heating**** Required installation height**** Visible height of grille**** Factory charged to 30 m pipe length, optional charging on page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.Outdoor units PUH-P1.6/2 YGAA also available in 220-240V, 1Ph, 50 Hz

GRILLE-TYPE FOR WIRED REMOTE CONTROL PLP-2.5 KCGRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-2.5 KLM

Page 48: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

48

● Wired remote control or infrared remote control with24h-timer

● PLH units with additional electrical heating for a warmstart and to increase capacityof heat pump

● Compact dimensions● Extremely quiet operation

noise, PLA-P3AA just 28 dB(A)● Weight reduced for PLA-P6AA

from 46 kg to only 37 kg● 4 fan-stages for best comfort● Drain pump for 850 mm height

difference● Simple installation with easy

access drain and refrigerantpiping connections

● Adjustable air outlets for optimum airflow for ceilingheights up to 4.2 m

● Precisely directed airflow toprevent dirt built-up and staining of ceiling tiles

● Rotary and scroll compressors● Factory charged with R407C● Long-life air filter● Twin, triple, quadruple

configuration possible, on page 72

Accessories: ● Space panel enables

installation into ceiling void of just 258 mm depth

● High efficiency filter and external airflow

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim Series PLA Cooling / HeatingPLH Cooling / Heating4-Way-In-Ceiling Cassette Systems

Page 49: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

49

PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATINGINDOOR UNIT PLA-P3 AA PLA-P4 AA PLA-P5 AA PLA-P6 AAINDOOR UNIT WITH ELECTRICAL HEATING PLH-P3 AAH PLH-P4 AAH PLH-P5 AAH PLH-P6 AAHCAPACITY (kW) Cooling 7.8 9.7 12.8 14.3

Heating* 9.3 (11.4) 10.6 (12.7) 14.9 (17.9) 17.1 (20.1)AIRFLOW (m3/h) Low 900 1200 1320 1320

Middle 1 960 1380 1500 1500Middle 2 1080 1560 1680 1680High 1200 1680 1800 1800

NOISE dB(A) Low 28 33 35 37High 34 41 43 45

WEIGHT PLA incl. Grille (kg) 24/29 30/35 30/35 32/37WEIGHT PLA incl. Grille (kg) 26/31 32/37 32/37 34/39DIMENSIONS (mm) Width 840 840 840 840Indoor unit Depth 840 840 840 840

Height** 258 298 298 298DIMENSIONS (mm) Width 950 950 950 950Grille Depth 950 950 950 950

Height*** 30 30 30 30ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.81 1.25 1.43 1.64

Heating* 0.81 (8.75) 1.25 (10.83) 1.43 (12.5) 1.64 (12.5)OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAAPOWER CONSUMPTION (kW) Cooling 3.4 3.7 5.0 5.9

Heating* 3.5 (5.6) 3.9 (6.0) 5.3 (8.3) 6.4 (9.4)AIRFLOW (m3/h)

3000 5100 57006000

NOISE dB(A) 49 51 55 57WEIGHT (kg) 82 96 122 122DIMENSIONS (mm) Width 900 900 1050 1050

Depth 350 350 350 350Height 855 1260 1260 1260

MAX. PIPE LENGTH (m) 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 50 50 50 50CHARGE R407C**** (kg) 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10ø (mm) Gas 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0

Heating 5.6 5.9 8.2 9.6

**** Values given in brackets incl. additional electrical heating**** Required installation height**** Visible height of grille**** Factory charged to 30 m pipe length, optional charging on page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.

GRILLE-TYPE FOR WIRED REMOTE CONTROL PLP-6 AAMGRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6 AALM

Page 50: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

50

● Wired remote control with 24h-timer

● PCH units with additional electrical heating for a warmstart and to increase capacityof heat pump

● Adjustable air outlets for optimum airflow for ceilingheights up to 3.5 m

● Rotary and scroll compressors● Factory charged with R407C● Long-life air filter● 4 fan-stages for optimum

comfort

● Swing louvres with `Auto Angle´ airflow

● Twin, triple, quadruple configuration possible, on page 72

Accessories: ● High efficiency filter● Drain pump● Infrared remote control

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPCA Cooling / HeatingPCH Cooling / HeatingCeiling Suspended Systems

Page 51: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

51

PCA/PCH CEILING SUSPENDED SYSTEMS COOLING / HEATINGINDOOR UNIT PCA-P2 GA PCA-P2.5 GA PCA-P3 GA PCA-P4 GA PCA-P5 GA PCA-P6 GAINDOOR UNIT WITH ELECTRICAL HEATING PCH-P2 GAH PCH-P2.5 GAH PCH-P3 GAH PCH-P4 GAH PCH-P5 GAH PCH-P6 GAHCAPACITY (kW) Cooling 5.4 6.7 7.5 9.7 12.4 14.3

Heating* 6.3 (7.7) 7.3 (9.4) 9.2 (11.3) 10.6 (13.4) 14.9 (17.9) 17.1 (20.1)AIRFLOW (m3/h) Low 600 840 840 1200 1620 1620

Middle 1 660 900 900 1260 1800 1800Middle 2 720 960 960 1380 1920 1920High 780 1080 1080 1500 2040 2040

NOISE dB(A) Low 37 37 37 40 41 42High 42 43 43 45 46 48

WEIGHT PCA (kg) 27 34 34 37 43 45WEIGHT PCH (kg) 28.5 36 36 39.5 46 48DIMENSIONS (mm) Width 1000 1310 1310 1310 1620 1620

Depth 680 680 680 680 680 680Height 210 210 210 270 270 270

ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50RUNNING CURRENT (A) Cooling 0.43 0.55 0.55 0.7 1.1 1.1

Heating* 0.43 (5.83) 0.55 (8.75) 0.55 (8.75) 0.7 (11.25) 1.1 (12.5) 1.1 (12.5)OUTDOOR UNIT PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAAPOWER Cooling 2.4 2.65 3.4 3.6 4.9 5.9CONSUMPTION (kW) Heating* 2.4 (3.8) 2.7 (4.8) 3.5 (5.6) 3.8 (6.55) 5.1 (8.1) 6.3 (9.3)AIRFLOW (m3/h) 3300 3000 3000 5100 5700 6000NOISE dB(A) 48 48 49 51 55 57WEIGHT (kg) 71 82 82 96 122 122DIMENSIONS (mm) Width 900 900 900 900 1050 1050

Depth 350 350 350 350 350 350Height 855 855 855 1260 1260 1260

MAX. PIPE LENGTH (m) 40 50 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 50 50 50 50 50CHARGE R407C** (kg) 2.6 3.1 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10 10 10ø (mm) Gas 16 16 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 3.7 4.5 5.3 5.5 7.6 9.0

Heating 3.8 4.3 5.6 5.8 8.1 9.6

** Values given in brackets incl. additional electrical heating** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Optional

Page 52: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

52

Mr. Slim SeriesPCA Cooling / HeatingCeiling Suspended Systems For Applications In Kitchens

● The established ceiling suspended system consistingof stainless steel for applica-tions in kitchens

● The special construction enables easy cleaning of thecasing and of all airflow parts

● Oil particles can be filtered 1.5times more efficient comparedto conventional types due to high performance filter (optional)

● On the rear panel roundknockout opening (Ø 200 mm)allows more comfort by supplying fresh air

● Rotary and scroll compressors

● Factory charged with R407C● Wired remote control with

24h-timer● Twin configuration possible,

on page 72

Accessories:● Oil mist filter (12 pcs.)PAC-SG 38 KF-E

For detailed descriptionsplease view on page 70 andthe following

Page 53: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

53

PCA CEILING SUSPENDED SYSTEMS COOLING / HEATINGINDOOR UNIT PCA-P3 HA PCA-P5 HACAPACITY (kW) Cooling 7.5 13.0

Heating 9.2 16.0AIRFLOW (m3/h) Low 1020 1800

High 1140 2280NOISE dB(A) Low 34 44

High 38 50WEIGHT (kg) 41 56DIMENSIONS (mm) Width 1136 1520

Depth 650 650Height 280 280

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50

(V, PHASE, Hz)RUNNING CURRENT (A) 0.55 1.1

OUTDOOR UNIT PUH-P3 YGAA PUH-P5 YGAA

POWER Cooling 3.36 4.90CONSUMPTION (kW) Heating 3.41 4.98AIRFLOW (m3/h) 3000 5700NOISE dB(A) 49 55WEIGHT (kg) 82 122DIMENSIONS (mm) Width 900 1050

Depth 350 350Height 855 1260

MAX. PIPE LENGTH (m) 50 50MAX. HEIGHT DIFFERENCE (m) 50 50CHARGE R407C* (kg) 3.3 4.6PIPE SIZE Liquid 10 10ø (mm) Gas 16 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.30 7.60

Heating 5.60 8.10

* Factory charged to 30 m pipe length, optional charging on page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 54: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

54

Mr. Slim SeriesPKA Cooling / HeatingPKH Cooling / HeatingWall Mounted Systems

● Infrared remote control with24h-timer

● PKH units with additional electrical heating for a warmstart and to increase capacityof heat pump

● Slim compact units for wallmounting

● Simple installation with easyaccess drain and refrigerantpiping connections

● Rotary and scroll compressors● Factory charged with R407C● Easily removable long-life

air filter

● PKA/H-P1.6/2 GAL/H with 4 fan-stages

● Swing louvres with `Auto Angle´ airflow

● Twin, triple, quadruple configuration possible, on page 72

Accessories: ● Drain pump● Wired remote control

For detailed descriptionsplease view on page 70 andthe following

Page 55: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

55

PKA/PKH WALL MOUNTED SYSTEMS COOLING / HEATINGINDOOR UNIT PKA-P1.6 GAL PKA-P2 GAL PKA-P2.5 FAL PKA-P3 FAL PKA-P4 FALINDOOR UNIT WITH ELECTRICAL HEATING PKH-P1.6 GALH PKH-P2 GALH PKH-P2.5 FALH PKH-P3 FALH PKH-P4 FALHCAPACITY (kW) Cooling 4.5 5.4 6.5 7.9 9.5

Heating* 5.0 (5.8) 6.3 (7.1) 7.4 (9.5) 9.5 (11.6) 10.9 (13.3)AIRFLOW (m3/h) Low 540 540 900 900 1320

Middle 1 600 600 – – –Middle 2 660 660 – – –High 720 720 1200 1200 1680

NOISE dB(A) Low 36 36 39 39 41High 43 43 45 45 46

WEIGHT PKA (kg) 16 16 24 24 28WEIGHT PKH (kg) 17 17 26 26 30DIMENSIONS (mm) Width 990 990 1400 1400 1680

Depth 235 235 235 235 235Height 340 340 340 340 340

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.33 0.33 0.43 0.43 0.52Heating* 0.33 (3.3) 0.33 (3.3) 0.43 (8.75) 0.43 (8.75) 0.52 (10.0)

OUTDOOR UNIT PUH-P1.6 YGAA PUH-P2 YGAA PUH-P2.5 YGAA PUH-P3 YGAA PUH-P4 YGAAPOWER Cooling 1.7 2.4 2.7 3.4 3.6CONSUMPTION (kW) Heating* 1.9 (2.7) 2.4 (3.2) 2.6 (4.7) 3.6 (5.7) 3.8 (6.2)AIRFLOW (m3/h) 2700 3300 3000 3000 5100NOISE dB(A) 47 48 48 49 51WEIGHT (kg) 55 71 82 82 96DIMENSIONS (mm) Width 900 900 900 900 900

Depth 350 350 350 350 350Height 650 855 855 855 1260

MAX. PIPE LENGTH (m) 40 40 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50CHARGE R407C** (kg) 2.5 2.6 3.1 3.3 4.0PIPE SIZE Liquid 10 10 10 10 10ø (mm) Gas 16 16 16 16 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7 4.3 5.3 5.6

Heating 2.6 3.8 4.5 5.6 5.9

Optional

** Values given in brackets incl. additional electrical heating** Factory charged to 20 m pipe length, PUH-P3/4 YGAA factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 56: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

56

Mr. Slim SeriesPSA Cooling / HeatingPSH Cooling / HeatingFloorstanding units

● Function panel case integratedand 24h-timer

● PSH units with additional electrical heating for a warmstart and to increase capacityof heat pump

● Compact design and high capacity

● Simple installation with easyaccess drain and refrigerantpiping connections

● Rotary and scroll compressors● Factory charged with R407C● Standard long-life filter● Twin and triple configuration

possible, on page 72

Accessories: Optional parts on page 70 and the following

Page 57: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

57

PSA/PSH FLOORSTANDING UNITS COOLING / HEATINGINDOOR UNIT PSA-P3 GA PSA-P4 GA PSA-P5 GA PSA-P6 GAINDOOR UNIT WITH ELECTRICAL HEATING PSH-P3 GAH PSH-P4 GAH PSH-P5 GAH PSH-P6 GAHCAPACITY (kW) Cooling 7.7 9.7 12.4 14.0

Heating* 9.3 (11.4) 10.9 (13.6) 14.6 (17.6) 17.1 (20.1)AIRFLOW (m3/h) Low 900 1440 1560 1620

High 1080 1860 1980 2100NOISE dB(A) Low 40 44 46 47

High 45 49 51 52WEIGHT PSA (kg) 43 51 51 53WEIGHT PSH (kg) 45 53 53 55DIMENSIONS (mm) Width 600 600 600 600

Depth 270 350 350 350Height 1900 1900 1900 1900

ELECTRICAL SUPPLY 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 0.68 1.1 1.26 1.62

Heating* 0.68 (8.75) 1.1 (11.25) 1.26 (12.5) 1.62 (12.5)OUTDOOR UNIT PUH-P3 YGAA PUH-P4 YGAA PUH-P5 YGAA PUH-P6 YGAAPOWER Cooling 3.4 3.8 5.0 5.8CONSUMPTION (kW) Heating* 3.5 (5.6) 3.9 (6.6) 5.4 (8.4) 6.1 (9.1)AIRFLOW (m3/h) 3000 5100 5700 6000NOISE dB(A) 49 51 55 57WEIGHT (kg) 82 96 122 122DIMENSIONS (mm) Width 900 900 1050 1050

Depth 350 350 350 350Height 855 1260 1260 1260

MAX. PIPE LENGTH (m) 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 50 50 50 50CHARGE R407C** (kg) 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10ø (mm) Gas 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 5.3 5.6 7.6 9.0

Heating 5.6 5.9 8.1 9.6

** Values given in brackets incl. additional electrical heating ** Factory charged to 30 m pipe length, optional charging on page 73The noise levels are measured at a position 1 m in front of and 1 m above.

Page 58: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

58

● Wired remote control with 24h-timer

● PEHD units with additionalelectrical heating for a warmstart and to increase capacityof heat pump

● Simple installation with easyaccess drain and refrigerantpiping connections

● PEAD/PEHD-P1.6/2/2.5 EA/Hairflow variable - draw in fromthe back or underside

● Rotary and scroll compressors● Factory charged with R407C

● Standard long-life filter● Twin, triple, quadruple

configuration possible, on page 72

Accessories: ● Drain pump● Fan motor (external static

pressure 130 Pa)

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim SeriesPEAD Cooling / HeatingPEHD Cooling / HeatingAbove-Ceiling Concealed Ducted Systems

Page 59: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

59

PEAD/PEHD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATINGINDOOR UNIT PEAD-P1.6EA PEAD-P2EA PEAD-P2.5EA PEAD-P3EA PEAD-P4EA PEAD-P5EA PEAD-P6EAINDOOR UNIT W. ELECTRICAL HEATING PEHD-P1.6EAH PEHD-P2EAH PEHD-P2.5EAH PEHD-P3EAH PEHD-P4EAH PEHD-P5EAH PEHD-P6EAHCAPACITY (kW) Cooling 4.5 5.6 6.7 7.7 9.7 12.3 14.1

Heating* 4.9 (5.9) 6.2 (7.2) 7.2 (8.7) 9.1 (11.2) 10.4 (12.9) 13.9 (16.9) 16.7 (19.7)AIRFLOW (m3/h) Low 660 810 1020 1200 1620 2100 2190

High 840 1020 1260 1500 2040 2520 2760EXTERNAL STATIC PRESSURE (Pa) 30(70) 30(70) 30(70) 70(130**) 70(130**) 70(130**) 70(130**)NOISE dB(A) Low 34(36) 36(38) 37(39) 37(40) 41(42) 44(46) 46(47)

High 38(43) 40(44) 41(46) 41(45) 46(48) 50(52) 51(53)WEIGHT PEAD (kg) 33 33 42 44 62 65 70WEIGHT PEHD (kg) 35 35 44 46 65 68 73DIMENSIONS (mm) Width 935 935 1175 1175 1415 1415 1715

Depth 700 700 700 740 740 740 740Height 295 295 295 325 325 325 325

ELECTRICAL SUPPLY220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 0.55 0.63 0.7 1.7 2.6 2.7 2.8Heating* 0.55 (4.71) 0.63 (4.8) 0.7 (7.0) 1.7 (10.4) 2.6 (12.6) 2.7 (15.2) 2.8 (15.2)

OUTDOOR UNIT PUH-P1.6YGAA PUH-P2YGAA PUH-P2.5YGAA PUH-P3YGAA PUH-P4YGAA PUH-P5YGAA PUH-P6YGAAPOWER Cooling 1.8 2.4 2.7 3.4 3.9 4.9 5.9CONSUMPTION (kW) Heating* 1.8 (2.8) 2.2 (3.2) 2.5 (4.0) 3.2 (5.3) 4.0 (6.5) 4.8 (7.8) 6.0 (9.0)AIRFLOW (m3/h) 2700 3300 3000 3000 5100 5700 6000NOISE dB(A) 47 48 48 49 51 55 57WEIGHT (kg) 55 71 82 82 96 122 122DIMENSIONS (mm) Width 900 900 900 900 900 1050 1050

Depth 350 350 350 350 350 350 350Height 650 855 855 855 1260 1260 1260

MAX. PIPE LENGTH (m) 40 40 50 50 50 50 50MAX. HEIGHT DIFFERENCE (m) 40 40 50 50 50 50 50CHARGE R407C*** (kg) 2.5 2.6 3.1 3.3 4.0 4.6 4.9PIPE SIZE Liquid 10 10 10 10 10 10 10ø (mm) Gas 16 16 16 16 18 18 18ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 2.5 3.7 4.3 5.3 5.6 7.6 9.0

Heating 2.6 3.8 4.5 5.6 5.9 8.2 9.6

*** Values given in brackets incl. additional electrical heating*** Fan motor optional on page 70*** Factory charged to 20 m pipe length, PUH-P3/P4/P5/P6 YGAA factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.

Page 60: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

60

● Wired remote control with 24h-timer

● Pressure to 150 Pa

● PUH-P8/10 MYA for simultaneous operation of Mr. Slim indoor units

● Factory charged with R407C

● Twin, triple, quadruple configuration possible, onpage 72

Accessories: Optional parts on page 70 andthe following

Mr. Slim SeriesPEH Cooling / HeatingConcealed Ducted Systems

Page 61: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

61

PEH CONCEALED DUCTED SYSTEMS COOLING/HEATINGINDOOR UNIT PEH-P8 MYA PEH-P10 MYACAPACITY (kW) Cooling 20.9 26.0

Heating 23.7 30.5AIRFLOW (m3/h) 3600 4800EXTERNAL STATIC PRESSURE (Pa) 50/150 50/150NOISE dB(A) 53 57WEIGHT (kg) 74 80DIMENSIONS (mm) Width 1580 1580

Depth 604 604Height 455 455

ELECTRICAL SUPPLY380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)

RUNNING CURRENT (A) Cooling 1.1 1.6Heating 1.1 1.6

OUTDOOR UNIT PUH-P8 MYA PUH-P10 MYAPOWER Cooling 7.92 9.96CONSUMPTION (kW) Heating 7.82 9.56AIRFLOW (m3/h) 11100 11100NOISE dB(A) 56 57WEIGHT (kg) 215 220DIMENSIONS (mm) Width 990 990

Depth 840 840Height 1715 1715

MAX. PIPE LENGTH (m) 50 50MAX. HEIGHT DIFFERENCE (m) 40 40CHARGE R407C* (kg) 6.0 6.5PIPE SIZE Liquid 12 12ø (mm) Gas 28 28ELECTRICAL SUPPLY

380-415, 3, 50 380-415, 3, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 13 16

Heating 12.8 15.4

* Factory charged, please view page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.

Rating conditions:COOLING Indoor: 15°C - 24°C WB

Outdoor: -15°C - 46°C DBHEATING Indoor: 15°C - 27°C WB

Outdoor: -12°C - 18°C DB

Page 62: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

62

Mr. Slim R410A-SeriesPower InverterSplit and Multi-Split SystemsThe established Mr. Slim Series with inverter technology - efficient, economical and very quiet.

Page 63: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

6363

POWER INVERTER-HEAT PUMP UNITSPLA 4-WAY-IN-CEILING CASSETTE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64PKA WALL-MOUNTED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66PEAD CEILING CONCEALED SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68

Advantages of Mr. Slim R410A-Series Power Inverter● New inverter-technology and

refrigerant R410A enable highenergy-efficiency

● The wide range of perfor-mance allows an optimum of convenience - for a quickcooling and heating

● All outdoor units with LOWNOISE - mode, only 44 dB(A)at PUHZ-RP3VHA

● The indoor units “RP” can be connected with Mr. SlimR407C outdoor units

● Multi Split simultaneous operation

● Standard long-life filters● Auto change over between

cooling and heating mode● A-Control makes servicing

easier. Automatic switchingbetween heating and coolingis available on heat pumpunits. Error codes are shownat remote controls display ofindoor units

● Lossnay heat exchange ventilators connectable

● Factory charged with refrigerant R410A

● Wired or infrared remote controller optional

NEW!

● Remote monitoring● Maintenance Tool for control

and service● All models can be interfaced

to Building Management Systems by Lon Works Interface

● Ceiling cassette models withcondensate pump

● Winter kit as standard, cooling up to -15°C. If the unitis placed in wind direction usethe optional part, view page70 and the following

Rating conditions Mr. Slim Series:● COOLING

Indoor: 19°C - 35°C DB15°C - 22.5°C WB

Outdoor: -15°C - 46°C DB● HEATING

Indoor: 17°C - 28°C DBOutdoor: -11°C - 24°C DB

-12°C - 18°C WB

Page 64: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

64

NEW!

● Wired or infrared remote control with 24h-timer provided

● Space-saving, quadratic design

● Installation height only 258mm (PLA-RP3 AA)

● Quiet operation noise - just 28 dB(A) (PLA-RP3 AA)

● Drain pump for 850 mm heightdifference

● Prepared duct connections:round 150 mm, rectangular350 x 100 mm

● 4 fan-stages for best comfort● Precisely directed airflow

to prevent dirt built-up andstaining of ceiling tiles

● Adjustable air outlets for optimum airflow for ceilingheights up to 4.2 m

● Standard long-life filter -cleaning necessary every2,500 operating hours

● Simple installation with easyaccess drain and refrigerantpiping connections

● Factory charged with R410A● Rotary and scroll compressors● Multi Split simultaneous

operation, view page 72

Accessories:● Space panel for installation of

PLA-RP4/5/6AA into ceilingvoid of just 258 mm depth

● High efficiency filter and external airflow

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim Power InverterPLA Cooling / Heating4-Way-In-Ceiling Cassette Systems

Page 65: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

65

POWER INVERTER PLA 4-WAY-IN-CEILING CASSETTE SYSTEMS COOLING / HEATINGINDOOR UNIT PLA-RP3 AA PLA-RP4 AA PLA-RP5 AA PLA-RP6 AACAPACITY COOLING (Min. - Nominal - Max.) kW 3.3 - 7.1 - 8.1 5.0 - 10.0 - 11.4 6.0 - 12.5 - 14.0 6.2 - 14.0 - 15.3CAPACITY HEATING (Min. - Nominal - Max.) kW 3.5 - 8.0 - 10.2 5.6 -11.2 - 14.0 6.0 - 14.0 - 16.0 6.2 - 16.0 - 18.0COP Cooling/Heating 3.60/3.42 3.30/3.30 3.21/3.28 2.81/3.26AIRFLOW (m3/h) Low 900 1200 1320 1320

Middle 1 960 1380 1500 1500Middle 2 1080 1560 1680 1680High 1200 1680 1800 1800

NOISE dB(A) Low 28 33 37 37 High 34 41 45 45

WEIGHT incl. Grille (kg) 24/29 30/35 30/35 32/37DIMENSIONS (mm) Width 840 840 840 840 Indoor unit Depth 840 840 840 840

Height** 258 298 298 298DIMENSIONS (mm) Width 950 950 950 950 Grille Depth 950 950 950 950

Height*** 30 30 30 30ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50RUNNING CURRENT (A) Cooling 0.79 1.25 1.43 1.6

Heating 0.79 1.25 1.43 1.6OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHAPOWER Cooling 1.97 3.03 3.89 4.99CONSUMPTION (kW) Heating 2.34 3.39 4.27 4.91AIRFLOW (m3/h)

3300 6000 6000 6000

NOISE dB(A) 44*/47 46*/49 47*/50 48*/50WEIGHT (kg) 75 121 121 121DIMENSIONS (mm) Width 950 900 900 900

Depth 360 360 360 360Height 943 1350 1350 1350

MAX. PIPE LENGTH (m) 50 75 75 75MAX. HEIGHT DIFFERENCE (m) 30 30 30 30CHARGE R410A**** (kg) 3.5 5.5 5.5 5.5PIPE SIZE Liquid 10 10 10 10ø (mm) Gas 16 16 16 16ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 8.0 12.3 15.8 20.3

Heating 9.7 13.9 17.5 20.7CIRCUIT BREAKER (A) 25 32 32 40

**** LOW NOISE mode**** Required installation height**** Visible height of grille**** Factory charged to 30 m pipe length, optional charging on page 73The noise levels are measured at a position 1.5 m below the unit in anechoic chamber.Indoor units "RP" can be connected with Mr. Slim R407C outdoor units.

GRILLE-TYPE FOR WIRED REMOTE CONTROL PLP-6AAMGRILLE-TYPE FOR INFRARED REMOTE CONTROL PLP-6AALM

Page 66: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

66

NEW!

● Infrared remote control with24h-timer

● Slim compact units for wallmounting

● Flexible louvre for evenlyspread of air

● Simple installation with easyaccess drain and refrigerantpiping connections

● Easily removable long-life airfilter

● Factory charged with R407C

● Rotary and scroll compressors● Multi Split simultaneous

operation possible, page 72

Accessories:● Drain pump● Wired remote control

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim Power InverterPKA Cooling / HeatingWall Mounted Systems

Page 67: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

67

POWER INVERTER PKA WALL MOUNTED SYSTEMS COOLING / HEATINGINDOOR UNIT PKA-RP3FAL PKA-RP4FALCAPACITY COOLING (Min. - Nominal - Max.) kW 3.3 - 7.1 - 8.1 5.0 - 10.0 - 11.4 CAPACITY HEATING (Min. - Nominal - Max.) kW 3.5 - 8.0 - 10.2 5.6 - 11.2 - 14.0 COP Cooling/Heating 3.59 / 3.33 3.41 / 3.45 AIRFLOW (m3/h) Low 900 1320

High 1200 1680 NOISE dB(A) Low 39 41

High 45 46WEIGHT (kg) 24 28 DIMENSIONS (mm) Width 1400 1680

Depth 235 235 Height 340 340

ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50 220-240, 1, 50RUNNING CURRENT (A) Cooling 0.43 0.52

Heating 0.43 0.52OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA POWER Cooling 1.98 2.93 CONSUMPTION (kW) Heating 2.40 3.25 AIRFLOW (m3/h) 3300 6000 NOISE dB(A) 44*/47 46*/49WEIGHT (kg) 75 121DIMENSIONS (mm) Width 950 950

Depth 360 360 Height 943 1350

MAX. PIPE LENGTH (m) 50 75MAX. HEIGHT DIFFERENCE (m) 30 30 CHARGE R410A** (kg) 3.5 5.5 PIPE SIZE Liquid 10 10 ø (mm) Gas 16 16 ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 (V, PHASE, Hz)RUNNING CURRENT (A) Cooling 8.0 12.3

Heating 9.7 13.9

CIRCUIT BREAKER (A) 25 32

Optional

** LOW NOISE mode** Factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.Indoor units “RP” can be connected with Mr. Slim R407C outdoor units.

Page 68: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

68

● Wired remote control with 24h-timer

● Standard long-life filter● Installation height only 325

mm● Simple installation with easy

access drain and refrigerantpiping connections

● Factory charged with R410A● Rotary and scroll compressors

● Multi Split simultaneous operation possible, page 72

Accessories:● Drain pump● Fan motor (external static

pressure 130 Pa)

For detailed descriptionsplease view on page 70 andthe following

Mr. Slim Power InverterPEAD Cooling / HeatingAbove-Ceiling Concealed Ducted Systems

NEW!

Page 69: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

69

POWER INVERTER PEAD ABOVE-CEILING CONCEALED DUCTED SYSTEMS COOLING / HEATINGINDOOR UNIT PEAD-RP3EA PEAD-RP4EA PEAD-RP5EA PEAD-RP6EACAPACITY COOLING (Min. - Nominal - Max.) kW 3.3 - 7.1 - 8.1 5.0 - 10.0 - 11.2 6.0 - 12.5 - 14.0 6.2 - 14.0 - 15.3CAPACITY HEATING (Min. - Nominal - Max.) kW 3.5 - 8.0 - 10.2 5.6 - 11.2 - 14.0 6.0 - 14.0 - 16.0 6.2 - 16.0 - 18.0COP Cooling/Heating 3.30/3.42 3.25/3.22 3.39/3.41 2.85/3.36AIRFLOW (m3/h) Low 1200 1620 2010 2190

High 1500 2040 2520 2760EXTERNAL STATIC PRESSURE (Pa) 70(130**) 70(130**) 70(130**) 70(130**)NOISE dB(A) Low 37(40) 41(42) 44(46) 46(47)

High 41(45) 46(48) 50(52) 51(53)WEIGHT (kg) 44 62 65 70DIMENSIONS (mm) Width 1175 1415 1415 1715

Depth 740 740 740 740Height 325 325 325 325

ELECTRICAL SUPPLY (V, PHASE, Hz) 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50RUNNING CURRENT (A) Cooling 1.6 2.5 2.6 2.7

Heating 1.6 2.5 2.6 2.7OUTDOOR UNIT PUHZ-RP3VHA PUHZ-RP4VHA PUHZ-RP5VHA PUHZ-RP6VHAPOWER Cooling 2.15 3.08 3.69 4.91CONSUMPTION (kW) Heating 2.34 3.48 4.11 4.76AIRFLOW (m3/h) 3300 6000 6000 6000 NOISE dB(A) 44*/47 46*/49 47*/50 48*/50 WEIGHT (kg) 75 121 121 121DIMENSIONS (mm) Width 950 950 950 950

Depth 360 360 360 360 Height 943 1350 1350 1350

MAX. PIPE LENGTH (m) 50 75 75 75 MAX. HEIGHT DIFFERENCE (m) 30 30 30 30 CHARGE R410A*** (kg) 3.5 5.5 5.5 5.5PIPE SIZE Liquid 10 10 10 10 ø (mm) Gas 16 16 16 16 ELECTRICAL SUPPLY

220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50(V, PHASE, Hz)RUNNING CURRENT (A) Cooling 8.0 12.3 15.8 20.4

Heating 9.7 13.9 17.5 20.7

CIRCUIT BREAKER (A) 25 32 32 40

*** LOW NOISE mode*** Fan motor optional 130 Pa*** Factory charged to 30 m pipe length, please also view page 73The noise levels are measured at a position 1 m in front of and 1 m below the unit in anechoic chamber.Indoor units "RP" can be connected with Mr. Slim R407C outdoor units.

Page 70: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

70

Mr. Slim R407C/R410A-SeriesAccessories

PART.NO. DESCRIPTION

PLA/PLH 4-WAY-IN-CEILING CASSETTE SYSTEMSPAC-SEO6 WP-E Wide panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAHPAC-SEO1 AS-E Space panel for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAHPAC-SE21 TM-E Multi-function casement for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAHPAC-SE13 KF-E High efficiency filter for PLA-P 1.6/2/2.5 KA, PLH-P 1.6/2/2.5 KAH (PAC-SE21 TM-E needed)PAC-SE60 AS-E Space panel for PLA-P 4/5/6 AA, PLH-P 4/5/6 AAHPAC-SG03 TM-E Multi-function casement for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAHPAC-SG01 KF-E High efficiency filter for PLA-P 3/4/5/6 AA, PLH-P 3/4/5/6 AAH (PAC-SG03 TM-E needed)

PCA/PCH CEILING SUSPENDED SYSTEMSPAC-SE85 DMA-E Drain pump for PCA-P 2/2.5/3 GA, PCH-P2/2.5/3 GAHPAC-SE86 DMA-E Drain pump for PCA-P 4/5/6 GA, PCH-P4/5/6 GAHPAC-SE80 KF-E High efficiency filter for PCA-P2 GA, PCH-P2 GAHPAC-SE81 KF-E High efficiency filter for PCA-P2.5/3/4 GA, PCH-P2.5/3/4 GAHPAC-SE82 KF-E High efficiency filter for PCA-P5/6 GA, PCH-P5/6 GAHPAC-SL99A-E Infrared remote control for PCA-P/PCH-P

PCA CEILING SUSPENDED SYSTEMS FOR KITCHEN APPLICATIONSPAC-SG38KF-E Special high efficiency oil filter, 12 pieces

PKA/PKH WALL-MOUNTED SYSTEMSPAC-SE88 DM-E Drain pump PKA-P/PKH-PPAR-20MAAT-E Wired remote control for PKH-P/PKA-P

PEAD/PEHD CEILING CONCEALED SYSTEMSPAC-KE03 DM-F Drain pump for PEAD-P/PEHD-PPAC-SK005 MT-F Fan motor 130 Pa pressure for PEAD-P3 EA/PEHD-P3 EAHPAC-SK004 MT-F Fan motor 130 Pa pressure for PEAD-P4 EA/PEHD-P4 EAHPAC-SK003 MT-F Fan motor 130 Pa pressure for PEAD-P5/6 EA/PEHD-P5/6 EAH

PU/PUH OUTDOOR UNITSPAC-SF37 DS-E Drain socket for Mr. Slim outdoor units P1.6 – P6PAC-SF08 SG-E Air outlet guide for Mr. Slim outdoor units P1.6 – P6 (for P4/5/6 2x PAC-SF08 SG-E)PAC-SF16 DP-E Drain pan PU(H)-P 1.6/4PAC-SF17 DP-E Drain pan PU(H)-P 5/6PAC-SF09 AG Airflow panel for cooling to -15° C for P1.6 – P6 (for P4/5/6 2x PAC-SF09 AG)

PUHZ OUTDOOR UNITSPAC-SG61DS-E Drain socket for Mr. Slim Power Inverter outdoor units RP3-RP6PAC-SG59SG-E Air outlet guide for outdoor units RP3-RP6. RP4/5/6 require two PAC-SG59SG-EPAC-SG64DP-E Drain pan for PUHZ-RP3/4/5/6 VHA

Accessories Indoor / Outdoor units

Page 71: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

71

Mr. Slim R407C/R410A-SeriesAccessories

PART.NO. DESCRIPTIONPAC-SE41 TS-E External Temperature SensorPAC-SF48 MA-E A/M Net-ConverterPAC-SF40 RM-E Operation remote controller boardPAC-SE55 RA-E Remote on/offCMS-MNF-B Maintenance Tool, to use with PAC-SF48 MA-E and PAC-SC34 KUALMAP02-E LonWorks®-Interface, to use with PAC-SF48 MA-E and PAC-SC50 KUAPAC-YT32PTA LCD weekly set back program timer – operation only with wired remote control modelsPAC-SF50MA A/M Net-Converter for Mr. Slim Inverter PUHZ R410 APAC-SC50KUA Power SupplyPAC-SK52ST Service-Display for outdoor units P1-P6 and RP3/4/5/6

Control Accessories

Further information: Planning handbook Mr. Slim Series

Page 72: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

72

Mr. Slim R407C:

** Attention: Only indoor units of same type can be installed.In Multi-Split-Mode all indoor units have to be installed in the same room because of temperature sensein the master unit.

** RP1.6/2/2.5 available from August 2004

INDOOR UNITS PLA-P/PLH-P1.6/2/2.5/3/4/5 PSA-P/PSH-P3/4/5PCA-P/PCH-P2/2.5/3/4/5 PEAD-P/PEHD-P1.6/2/2.5/3/4/5PKA-P/PKH-P1.6/2/2.5/3/4 PMH-P1.6/2

OUTDOOR UNITSCOMIBINATION Twin 50:50 Twin 50:50 Triple 33:33:33 Triple 25:25:50 Triple 20:40:40 Quadruple 25:25:25:25PU(H)-P3 YGAA 1.6 + 1.6 – –PU(H)-P4 YGAA 2 + 2 – –PU(H)-P5 YGAA 2.5 +2.5 – –PU(H)-P6 YGAA 3 + 3 2 + 2 + 2 1.6 + 1.6 + 3PUH-P8 MYA – 4 + 4 2.5 + 2.5 + 2.5 2 + 2 + 4 1.6 + 3 + 3 2 + 2 + 2 + 2PUH-P10 MYA – 5 + 5 3 + 3 + 3 2.5 + 2.5 + 5 2 + 4 + 4 2.5 + 2.5 + 2.5 + 2.5DISTRIBUTOR SDD-50 DA-E SDD-50WSA-E SDT-111 SA-E SDT-112 SA-E SDT-122 SA-E SDT-1111 SA-E

Combinations:

Mr. Slim R410A:

INDOOR UNITS** PLA-RP1.6/2/2.5/3PKA-RP1.6/2/2.5/3

PEAD-RP1.6/2/2.5/3OUTDOOR UNITSCOMBINATION Twin 50:50 Triple 33:33:33PUHZ-RP3VHA 1.6 + 1.6** – PUHZ-RP4VHA 2 + 2** – PUHZ-RP5VHA 2.5 +2.5** – PUHZ-RP6VHA 3 + 3 2 + 2 + 2** DISTRIBUTOR SDD-50SR-E SDT-111R-E

Combinations:

Accessories forMulti Split Systems*/Distributors:

● Twin, triple, quadruple configuration of Mr. Slim indoor units with single outdoorunits possible.

● Ideally suited to open plan areas in small- to medium-sized offices or shops.

Page 73: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

73

Mr. Slim-SeriesTechnical Data RefrigerantsR407C/R410A

● Charge concerning single operation,optional charges for simultaneous operation as in the planning guide described.

● Outdoor units P1-2.5: Factory charged to 20 m pipe length

● Outdoor units P3-P6: Factory chargedto 30 m pipe length

● Outdoor units P8 and P10: Factory charged 6 kg and 6.5 kg R407C. Please view in the table above pipe length and charging data

Charge R407C

Correction Factor R407C

EFFICIENCY CLASS CORRECTION FACTOR CAPACITY OF COOLING/HEATING

PIPE LENGTH (ONE WAY)/M 5 10 15 20 25 30 35 40 45 50

P1 1.00/1.00 0.992/0.997 0.983/0.996 0.978/0.994 0.966/0.991 0.959/0.989 – / – – / – – / – – / –

P1.6 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 – / – – / –

P2 1.00/1.00 0.993/0.998 0.984/0.995 0.978/0.993 0.969/0.990 0.961/0.988 0.956/0.985 0.948/0.983 – / – – / –

P2.5 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978

P3 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978

P4 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978

P5 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978

P6 1.00/1.00 0.975/0.998 0.955/0.995 0.935/0.993 0.918/0.990 0.900/0.988 0.884/0.985 0.869/0.983 0.855/0.980 0.840/0.978

P8 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.965/0.995 0.960/0.995 0.940/0.995 0.935/0.995 0.930/0.995

P10 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.960/0.995 0.958/0.995 0.955/0.995 0.950/0.995 0.950/0.995

CHARGING (ONE WAY) IN kg10 m 20 m 30 m 40 m 50 m

PUH-P1 VGAA 1.7 1.7 1.8 – –PU(H)-P1.6 YGAA 2.5 2.5 2.6 3.0 –PU(H)-P2 YGAA 2.6 2.6 3.1 3.7 –PU(H)-P2.5 YGAA 3.1 3.1 3.3 3.9 4.5PU(H)-P3 YGAA – 3.3 – 3.9 4.5PU(H)-P4 YGAA – 4.0 – 4.7 5.4PU(H)-P5 YGAA – 4.6 – 5.3 6.0PU(H)-P6 YGAA – 4.9 – 5.6 6.3PUH-P8 MYA 7.0 7.5 8.0 8.5 9.0PUH-P10 MYA 7.5 8.0 8.5 9.0 9.5

OUTDOOR UNITS

Charge R410A● Outdoor units PUHZ-P3/4/5/6VHA

factory charged to 30 m pipe length(one-way), optional charges as in thetable.

Correction Factor R410A

EFFICIENCY CLASS CORRECTION FACTOR CAPACITY OF COOLING/HEATING

PIPE LENGTH (ONE WAY)/M 5 10 15 20 30 40 50 60 70 75

RP3 1.00/1.00 0.989/0.997 0.978/0.994 0.967/0.991 0.947/0.985 0.930/0.979 0.905/0.973 – / – – / – – / –

RP4 1.00/1.00 0.985/0.997 0.971/0.994 0.958/0.991 0.931/0.985 0.908/0.979 0.887/0.973 0.865/0.967 0.847/0.961 0.838/0.958

RP5 1.00/1.00 0.982/0.997 0.963/0.994 0.9470.991 0.914/0.985 0.885/0.979 0.858/0.973 0.834/0.967 0.812/0.961 0.802/0.958

RP6 1.00/1.00 0.976/0.997 0.953/0.994 0.932/0.991 0.893/0.985 0.858/0.979 0.828/0.973 0.800/0.967 0.776/0.961 0.764/0.958

CHARGING (ONE WAY) IN kg10 m 20 m 30 m 40 m 50 m 60 m 75 m

PUHZ-RP3VHA 3.1 3.3 3.5 4.1 4.7 – –PUHZ-RP4VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9PUHZ-RP5VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9PUHZ-RP6VHA 5.1 5.3 5.5 6.1 6.7 7.3 7.9

OUTDOOR UNITS

Page 74: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

74

For large applications such as office blocks, hotels andlarge retail stores, City Multi – variable refrigerant flow(VRF) multi-split systems – offer significant advantagesover centralised plant systems.A certain times of the year, many buildings can requirecooling in some areas and heating in others – even inadjacent rooms.The outstanding City Multi R2 and WR2 systems meetthis requirement by distributing surplus heat from cooling operations to rooms where it is needed. This can result in energy savings of up to 20% overconventional systems. The water-cooled WR-system is adaptable specially to high-rise buildings.

City Multi-Series Y and R2

Page 75: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

75

Advantages of theCity Multi-Series● City Multi Super Y-Series manages

up to 32 indoor units in a single refrigerant circle

● Simultaneous cooling and heatingwith incomparable 2-pipe-system

● By distributing surplus heat fromcooling operations to rooms whereit is needed, the result can be 15%- 20% energy savings over con-ventional systems

● Automatic switch of operatingmode (heating/cooling), the roomtemperature stays constant

● Many indoor units, capacity-stepsand installation possibilities to select

● Inverter-driven outdoor compressor units with very low start currents

● Remote control of individual indoor units, to centralised systems, right up to full interfacewith industry standard BuildingManagement Systems

CITY MULTI Y-SeriesCity Multi Y-Series utilise 2-pipetechnology for cooling and heatingmode. By manual switch the mostcomfortable air conditions can bechoosen. The system is very versatile, it is possible to install up to 32 different indoor units to a single refrigerant circle. The capacity of all installed indoor units can be 50% up to 130%.

CITY MULTI R2-SeriesThe City Multi range has been re-engineered to use R407Cozone-friendly refrigerant – withoutperformance loss. Modern buildings with a reduced exchangeof air, technical equipment likePCs, printer etc. which warm upthe air require efficient air conditioning with simultaneouscooling and heating. The "Fuzzy-logic” makes individual airconditioning with max. 24 indoorunits possible. Inverter-driven outdoor compressor units with verylow start currents save energy. Distributing surplus heat from cooling operations to rooms whereit is needed is another way to save energy.

Control options to suitevery kind of applicationCity Multi systems offer an extremelywide choice of control solutions,from remote control of individual indoor units, to centralised systemsand computer-aided systems whichallow to control up to 2,000 units.Right up to full interface with industry standard Building Management Systems.

Operating range of City Multi● Cooling: indoor 15° – 24°C

(WB)/outdoor -5° – 43°C (DB)(water temperature for WR2: 10°C – 45°C)

● Heating (Y-Series):indoor 15° – 27°C (DB)/outdoor -15° – 15.5°C (WB)

● Heating (R2-Series):indoor 15° – 27°C (DB)/outdoor -15° – 15.5°C (WB)(water temperature for WR2: 10°C – 45°C)

Features of City Multi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

City Multi Y-series - Outdoors units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

City Multi R2 series - Outdoors units and BC-controllers . . . . . . . . . . . . . . . . . . . . . . 82

PMFY/PLFY - Ceiling cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

PCFY/PKFY - Suspended indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

PEFY - Concealed ducted indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

PFFY - Floor standing indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

City Multi - Control accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

City Multi - Accessoires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Page 76: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

76

City Multi Systems:Economic, efficient and high-quality

CITY MULTI Y-SERIES� Switching between Heating and Cooling

Flexible and Powerful Response from Compact Dimensions Flexi-bility is the motto with the City Multi Y-Series. A wide line-up ofindoor units in combination with a flexible piping system can con-

form to any layout. From 8 to 32 indoor units, depending on capacity, can beconnected to Y-Standard, BIG Y and SUPER Y outdoor units.

All indoor units connected to only one refrigerant circuit. This enables easy airconditioning of areas requiring individual control. In common with the R2, theCity Multi Y-Series can be easily operated through a central controller.

Y-Series Outdoor unit

Indoor unit

Indoor unit

Header Branch

Page 77: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

77

CITY MULTI R2-SERIES � Simultaneous Cooling andHeating excellent air conditioningunder the aspect of economy.

The R2-System means that simulta-neous cooling and heating is possi-ble. With the BC Controller connecting from 4 to24 indoor units to one outdoor unit using only twopipes and energy-saving heat recovery operation,economy and efficiency are guaranteed. Smoothauto-switching (heating/cooling) based on settemperature realises easier operation and morecomfortable environment in auto-mode. TheWR2-System uses the same technical bases likethe well-known R2-System. But the WR2-Seriesis the world´s only simultaneous heating/coolingtwo-pipe system with water-cooled outdoor units.WR2-System is specially for high-rise buildings.

R2-SeriesOutdoor unit

WR2-SeriesOutdoor unit

Water piping

Two-Pipe system

Conference room (cooling)

BC Controller

Conferenceroom (heating)

Office (heating)

OA room(cooling)

Connection

Office (cooling)

World-wide the onlysystem for simultaneouscooling and heatingwith 2 pipes.

Page 78: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

78

Mitsubishi Electric FEATURES of CITY MULTIFlexible and AdaptableThe variety provided by 19 outdoor models and 65 indoor models (9 different types) increase design flexibility.

R40

7C

BIG Y-SERIES

SUPER Y-SERIES

R2-SERIES

BIG R2-SERIES

WR2-SERIES

The Y-Series: Cooling or heating mode, a maximum of 32 indoor unitsconnectable with one refrigerant circuit.

The R2-Series: Simultaneous heating/cooling with up to 24 indoor unitsand heat recovery by BC-controller.

WR2-Series:World´s only simultaneous heating/cooling two-pipe system with water-cooled outdoor units.

SERIES Outdoor Cooling Heating No. of Total Capacity of unit capacity capacity Connect capacity connectable

(kW) (kW) indoor units indoor units indoor models*

Y-SERIES PUMY-P125 YMA 14.0 16,0 1-8 50 - 130% 20 - 125PUY-P200 YEM-A 22.4 – 1-13PUY-P250 YEM-A 28.0 – 1-16PUY-P315 YEM-A 35.5 – 1-16 50 - 130 % 20 - 250PUHY-P200 YEM-A 22.4 25.0 1-13PUHY-P250 YEM-A 28.0 31.5 1-16PUHY-P315 YEM-A 35.5 40,0 1-16

PUHY-P400 YMF-C 45.0 50.0 1-2050 - 130% 25 - 250PUHY-P500 YMF-C 56.0 63.0 1-20

PUHY-P400 YMF-C + PUHN-P200 YMF-C 67.4 75.0 2-32PUHY-P400 YMF-C + PUHN-P250 YMF-C 73.0 81.5 2-32

50 - 130% 20 - 250PUHY-P500 YMF-C + PUHN-P200 YMF-C 78.4 88.0 2-32PUHY-P500 YMF-C + PUHN-P250 YMF-C 84.0 94.5 2-32

PURY-P200 YEM-A 22.4 25.0 1-1550 - 150% 20 - 250PURY-P250 YEM-A 28.0 31.5 1-16

PURY-P400 YMF-C 45.0 50.0 2-2450 - 150% 20 - 250PURY-P500 YMF-C 56.0 63.0 2-24

PQRY-P200 YMF-C 22.4 25.0 1-1550 - 150% 20 - 250PQRY-P250 YMF-C 28.0 31.5 1-16

* Indoor units available: Type 20 (2.2 kW) up to type 250 (28.0 kW)

Page 79: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

79

All City Multi indoor units are compatible to Y-Series,R2- and WR2-Series.

* L-model: low stat. pressure, H-model: high stat. pressure

Indoor units- Overview

Capacity Capacity code

Cooling capacity (kW)

Type Heating capacity (kW)

P 20

2.2

2.5

P 25

2.8

3.2

P 32

3.6

4.0

P 40

4.5

5.0

P 50

5.6

6.3

P 63

7.1

8.0

P 71

8.0

9.0

P 80

9.0

10.0

P 100

11.2

12.5

P 125

14.0

16.0

P 140

16.0

18.0

P 200

22.4

25.0

P 250

28.0

31.5

Ceiling Cassette Type(1-way airflow)

PMFY-VBM-A

Ceiling Cassette Type(2-way airflow)

PLFY-VLMD-A/-B

Ceiling Cassette Type(4-way airflow)

PLFY-VKM-A/VAM-A

Ceiling Concealed(horizontal airflow)

PEFY-VML-A/VMH-A

Ceiling Concealed(variable airflow)

PEFY-VMM-A

Ceiling Suspended Type

PCFY-VGM-A

Wall Mounted Type

PKFY-VAM-A

Wall Mounted Type

PKFY-VGM-A

Floor StandingExposed Type

PFFY-VLEM-A

Floor StandingConcealed Type

PFFY-VLRM-A

● ● ● ●

● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ● ● ● ● ●

● ● ● ●

● ●

● ● ●

● ● ● ● ● ●

● ● ● ● ● ●

L-model* H-model*

B-model A-model

Page 80: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

80

Outdoor units - Technical dataCity Multi Y-Series, Cooling or Heating

OUTDOOR UNIT PUMY-P125 YMAMODEL REFERENCE PUMY-P125 YMACAPACITY (kW) Cooling 14.0

Heating 16.0AIRFLOW (m3/h) 5400NOISE* dB(A) 54WEIGHT (kg) 127DIMENSIONS (mm) Width 1020

Depth 350Height* 1280

MAX. PIPE LENGTH** (m) 100MAX. HEIGHT DIFFERENCE (m) 30CHARGE R407C*** (kg) 8.5PIPE SIZE ø (mm) liquid 10

gas 18ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3INPUT POWER (kW) Cooling 5.95

Heating 5.58STARTING CURRENT (A) 8RUNNING CURRENT (A) 9.1INDOOR UNITS TO INSTALL (pcs.) 1-8 / 20-125

City MultiStandard Y:

PU(H)Y-P200/250/315

YEM-A

City MultiY-Series:

PUMY-P125 YMA

STANDARD Y OUTDOOR UNIT COOLING ONLY COOLING/HEATINGMODEL REFERENCE PUY- PUY- PUY- PUHY- PUHY- PUHY-

P200YEM-A P250YEM-A P315YEM-A P200YEM-A P250YEM-A P315YEM-ACAPACITY (kW) Cooling 22.4 28.0 35.5 22.4 28.0 35.5

Heating – – – 25.0 31.5 40.0AIRFLOW (m3/h) 12000 12000 12000 12000 12000 12000NOISE* dB(A) 56 57 60 56 57 60WEIGHT (kg) 225 225 240 225 225 240DIMENSIONS (mm) Width 990 990 990 990 990 990

Depth 840 840 840 840 840 840Height* 1755 1755 1755 1755 1755 1755

MAX. PIPE LENGTH** (m) 240 240 240 240 240 240MAX. HEIGHT DIFFERENCE (m) 50 50 50 50 50 50CHARGE R407C (kg) 7 7 9 7 7 9PIPE SIZE ø (mm) liquid 12 12 12 12 12 12

gas 28 28 35 28 28 35ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3 380-415V, 50Hz, 3 380-415V, 50Hz, 3INPUT POWER (kW) Cooling 6.32 8.54 12.3 6.32 8.54 12.3

Heating – – – 6.80 8.95 12.49STARTING CURRENT (A) 8 8 8 8 8 8RUNNING CURRENT (A) 10.6 14.4 20.3 11.4 15.1 20.6INDOOR UNITS TO INSTALL (Number/Type) 1-13/20-250 1-16/20-250 1-16/20-250 1-13/20-250 1-16/20-250 1-16/20-250

*** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.*** one-way*** Factory charged to 50 m pipe length (one-way)

Page 81: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

81

** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.** one-way

City Multi Big Y:PUHY-P400/500 YMF-C

City MultiSuper Y

BIG Y OUTDOOR UNITSMODEL REFERENCE PUHY-P400YMF-C PUHY-P500YMF-CCAPACITY (kW) Cooling 45.0 56.0

Heating 50.0 63.0 AIRFLOW (m3/h) 22200 22200 NOISE* dB(A) 60 60 WEIGHT (kg) 440 475 DIMENSIONS (mm) Width 1990 1990

Depth 840 840 Height 1715 1715

MAX. PIPE LENGTH** (m) 220 220 MAX. HEIGHT DIFFERENCE (m) 50 50 CHARGE R407C (kg) 16 22 PIPE SIZE ø (mm) liquid 16 16

gas 35 35ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3 INPUT POWER (kW) Cooling 16.3 20.5

Heating 15.2 19.0INDOOR UNITS TO INSTALL (pcs.) 1-20/25-250

MODEL REFERENCE Cooling capacity (kW) Heating capacity (kW) Noise level Indoor units to installdB(A) (pcs.)

Super Y PUHY-P400YMF-C + PUHN-P200YMF-C 67.4 75.0 61.5 2-32/20-250Super Y PUHY-P400YMF-C + PUHN-P250YMF-C 73.0 81.5 62.0 2-32/20-250Super Y PUHY-P500YMF-C + PUHN-P200YMF-C 78.4 88.0 61.5 2-32/20-250Super Y PUHY-P500YMF-C + PUHN-P250YMF-C 84.0 94.5 62.0 2-32/20-250

When adding 20 or more indoor units to one system transmission booster PAC-SF46EPA is needed. For connecting PUHN use SUPER Y Kit CMC-30A.

PUHN UNITSMODEL REFERENCE PUHN-P200YMF-C PUHN-P250YMF-CCAPACITY (kW) Cooling 22.4 28.0

Heating 25.0 31.5AIRFLOW (m3/h) 11100 11100NOISE* dB(A) 61 62WEIGHT (kg) 240 255DIMENSIONS (mm) Width 990 990

Depth 840 840Height 1715 1715

MAX. PIPE LENGTH** (m) 220 220MAX. HEIGHT DIFFERENCE (m) 50 50CHARGE R407C (kg) 6.5 8.5PIPE SIZE ø (mm) liquid 12 12

gas 28 28ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3INPUT POWER (kW) Cooling Depending of Combination

Heating

City Multi BIG Y and Super Y-Series

SUPER Y:COMBINATION OF BIG Y AND PUHN

Page 82: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

82

Outdoor units - Technical dataCity Multi R2-Series

City Multi R2:PURY-P 200/250

YEM-A

BC-Controller – requiredfor R2/WR2

R2-OUTDOOR UNITSPURY- PURY-

MODEL REFERENCE P200YEM-A P250YEM-ACAPACITY (kW) Cooling 22.4 28.0

Heating 25.0 31.5AIRFLOW (m3/h) 12000 12000NOISE* dB(A) 56 57WEIGHT (kg) 238 238DIMENSIONS (mm) Width 990 990

Depth 840 840Height 1755 1755

MAX. PIPE LENGTH** (m) 240 240MAX. HEIGHT DIFFERENCE (m) 50 50CHARGE R407C (kg) 10.5 10.5PIPE SIZE ø (mm) liquid 18 18

gas 28 28ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3 380-415V, 50Hz, 3INPUT POWER (kW) Cooling 6.32 8.54

Heating 6.80 8.95STARTING CURRENT (A) 8 8RUNNING CURRENT (A) 11.4 15.1INDOOR UNITS TO INSTALL (pcs.) 1-15/20-250 1-16/20-250

WR2-SERIES WITH WATER COOLED HEAT EXCHANGER (ONLY FOR INDOOR USE)MODEL REFERENCE PQRY-P200YMF-C PQRY-P250YMF-C CAPACITY (kW) Cooling 22.4 28.0

Heating 25.0 31.5COOLING WATER FLOW RATE (m3/h) 3.9 4.9PRESSURE DROP (k Pa) 8 10MAX. PIPING LENGTH** (m) 220 220REFRIGERANT CIRCUITMAX. HIGH DIFFERENCE (m) 50 50REFRIGERANT CIRCUITCHARGE R407C (kg) 7.5 8.5NOISE* dB(A) 51 52WEIGHT (kg) 270 280DIMENSIONS (mm) Width 1150 1150

Depth 500 500Height 1670 1670

ELECTRICAL SUPPLY (V, PHASE, Hz) 380-415V, 50Hz, 3INPUT POWER (kW) Cooling 7.6 9.7

Heating 7.4 9.4STARTING CURRENT (A) 12 12RUNNING CURRENT (A) 12.1 15.5PIPE SIZE ø (mm) liquid 18 18

GAS 28 28OPERATING TEMP. RANGE COOLING INDOOR 15ºC – 24ºC (WB) / watertemp.10º C – 45º C

HEATING INDOOR 15ºC – 27ºC (DB) / watertemp.10º C – 45º CINDOOR UNITS NO./TYPE 1-15/20-250 1-16/20-250

Note:1) Cooling/heating capacity indicates the maximum value

at operation under the following conditions:Cooling/outdoor: 35°C DB/24°C WBWatertemperature WR2 30°CHeating/outdoor: 7°C DB/6°C WBWatertemperature WR2 20°C

2) The ambient temperature of heat source units has to bekept below 40°C DB. The ambient relative humidity ofheat source units has to be kept below 80%

** Noise level measured at a position of 1min front of the unit.

** one-way

City Multi WR2:PQRY-P200/250 YMF-C

Cooling + Heating simultaneous with

heat recovery

BC-CONTROLLER FOR R2/WR2-SERIESMODEL REFERENCE CMB- CMB- CMB- CMB- CMB- CMB- CMB-

P104V-F P105V-F P106V-F P108V-F P1010V-F P1013V-F P1016V-FNUMBER OF CONNECTIONS 4 5 6 8 10 13 16PIPE SIZE EXT., ø (mm) liquid 18 18 18 18 18 18 18

gas 28 28 28 28 28 28 28BC-Controller at outdoor unitPIPE SIZE EXT. ø (mm) liquid 10 10 10 10 10 10 10

gas 16 16 16 16 16 16 16Indoor unit at BC-ControllerWEIGHT (kg) 24 27 29 34 39 47 54DIMENSIONS (mm) Width 648 648 648 648 648 1098 1098

Depth 432 432 432 432 432 432 432Height 284 284 284 284 284 284 284

ELECTRICAL SUPPLY, (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.07 0.08 0.09 0.13 0.16 0.2 0.25RUNNING CURRENT (A) 0.3 0.36 0.43 0.56 0.69 0.89 1.08

Page 83: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

83

City Multi Big R2:PURY-P400/500 YMF-C

Master-Controller

Note: The Slave BC-Controller canonly use in combination with the Master Controller

** The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber.** one-way

BIG R2-OUTDOOR UNITSMODEL REFERENCE PURY-P400YMF-C PURY-P500YMF-C CAPACITY (kW) Cooling 45,0 56,0

Heating 50.0 63,0 AIRFLOW (m3/h) 22200 22200 NOISE* dB(A) 60 60 WEIGHT (kg) 470 500 DIMENSIONS (mm) Width 1990 1990

Depth 840 840 Height 1715 1715

MAX PIPE LENGTH** (m) 250 250MAX HIGH DIFFERENCE (m) 50 50CHARGE R407C (kg) 20 22PIPE SIZE ø (mm) liquid 28 28

gas 35 35ELECTRICAL SUPPLY (V, Freq.,Phase) 380-415V, 50Hz, 3 INPUT POWER (Cooling) 16,3 20.5

(Heating) 15.2 19.0INDOOR UNITS TO INSTALL No./Type 2-24/20-250

MASTER-CONTROLLER FOR BIG R2-SERIES MODEL REFERENCE CMB- CMB- CMB- CMB-

P108V-FA P1010V-FA P1013V-FA P1016V-FANUMBER OF CONNECTIONS 8 10 13 16PIPE SIZE EXT., ø (mm) liquid 28 28 28 28

gas 35 35 35 35BC-Controller at outdoor unitPIPE SIZE EXT. ø (mm) liquid 10 10 10 10

gas 16 16 16 16Indoor unit at BC-ControllerPIPE SIZE EXT. ø (mm) liquid 12 12 12 12

gas 18 18 18 18Master-Controller at Slave-Controller 28 28 28 28WEIGHT (kg) 44 49 57 64DIMENSIONS (mm) Width 1110 1110 1110 1110

Depth 520 520 520 520Height 289 289 289 289

ELECTRICAL SUPPLY, (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.14 0.17 0.23 0.26RUNNING CURRENT (A) 0.58 0.7 0.89 1.08

MODEL REFERENCE CMB-P108V-FB

NUMBER OF CONNECTIONS 8PIPE SIZE EXT., ø (mm) liquid 12

gas 18Slave Controller at Master Controller 28PIPE SIZE EXT. ø (mm) liquid 10

gas 16Indoor unit at Slave ControllerWEIGHT (kg) 32DIMENSIONS (mm) Width 648

Depth 432Height 284

ELECTRICAL SUPPLY, (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.128RUNNING CURRENT (A) 0.53

SLAVE-CONTROLLER FOR BIG R2-SERIES

Slave-Controller

Page 84: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

84

Indoor Units - Technical Data

PMFY 1-WAY IN-CEILING CASSETTESMODEL REFERENCE PMFY-P20VBM-A PMFY-P25VBM-A PMFY-P32VBM-A PMFY-P40VBM-AGRILLE MODEL PMP-40 BM PMP-40 BM PMP-40 BM PMP-40 BMCAPACITY (kW) Cooling 2.2 2.8 3.6 4.5

Heating 2.5 3.2 4.0 5.0AIRFLOW (m3/h) Low 390 438 438 462

Middle 1 432 480 480 522Middle 2 480 512 512 582High 522 558 558 642

NOISE* (Low/High) dB(A) 27/35 32/37 32/37 33/39WEIGHT / incl. Grille (kg) 14 (17) 14 (17) 14 (17) 14 (17)DIMENSIONS (mm) (Grille) Width 854 (1000) 854 (1000) 854 (1000) 854 (1000)

Depth 395 (470) 395 (470) 395 (470) 395 (470)Height** 230 (30) 230 (30) 230 (30) 230 (30)

PIPE SIZE ø (mm) liquid 6 6 6 6gas 12 12 12 12

ELECTRICAL SUPPLY (V, Freq.,Phase) 220 – 240 V, 50 Hz, 1INPUT POWER (kW) 0.042 0.044 0.044 0.054RUNNING CURRENT (A) 0.2 0.21 0.21 0.26

PLFY 2-WAY IN-CEILING CASSETTESPLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY-MODEL REFERENCE

P20VLMD-B P25VLMD-B P32VLMD-B P40VLMD-B P50VLMD-B P63VLMD-B P80VLMD-A P100VLMD-A P125VLMD-AGRILLE MODEL CMP-40 CMP-40 CMP-40 CMP-40 CMP-63 CMP-63 CMP-63 CMP-125 CMP-125

VLW-B VLW-B VLW-B VLW-B VLW-B VLW-B LW-F LW-F LW-FCAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0

Heating 2.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0AIRFLOW (m3/h) Low 390 390 390 420 540 600 900 1260 1440

Middle 1 480 480 480 510 660 780 1020 1380 1620Middle 2 – – – – – – 1140 1560 1800High 570 570 570 630 750 930 1260 1740 1980

NOISE* (Low/High) dB(A) 27 / 33 27 / 33 27 / 33 29 / 36 31 / 37 32 / 39 36 / 43 37 / 43 40 / 46

WEIGHT / incl. Grille (kg) 23 (29.5) 23 (29.5) 24 (30.5) 24 (30.5) 27 (34.5) 28 (35.5) 41 (51) 56 (67.5) 56 (67.5)DIMENSIONS (mm) Width 776 (1080) 776 (1080) 776 (1080) 776 (1080) 946 (1250) 946 (1250) 1358 (1650) 1708 (2000) 1708 (2000)(Grille) Depth 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 606 (670) 606 (670) 606 (670)

Height** 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (20) 338 (8) 338 (8) 338 (8)PIPE SIZE ø (mm) liquid 6 6 6 6 6 10 10 10 10

gas 12 12 12 12 12 16 16 18 18ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.075 0.075 0.075 0.085 0.086 0.105 0.23 0.25 0.28RUNNING CURRENT (A) 0.37 0.37 0.37 0.42 0.43 0.51 1.1 1.2 1.35

PLFY 4-WAY IN-CEILING CASSETTESPLFY- PLFY- PLFY- PLFY- PLFY- PLFY- PLFY-

MODEL REFERENCE P32VKM-A P40VKM-A P50VKM-A P63VKM-A P80VAM-A P100VAM-A P125VAM-AGRILLE MODEL PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-2.5KC PLP-6AA PLP-6AA PLP-6AACAPACITY (kW) Cooling 3.6 4.5 5.6 7.1 9.0 11.2 14.0

Heating 4.0 5.0 6.3 8.0 10.0 12.5 16.0AIRFLOW (m3/h) Low 780 780 780 840 960 1200 1320

Middle 1 840 840 840 900 1080 1380 1500Middle 2 870 870 900 960 1200 1560 1680High 900 900 960 1020 1320 1680 1800

NOISE* (Low/High) dB(A) 31 / 35 31 / 35 32 / 37 35 / 39 30 / 37 33 / 41 35 / 43

WEIGHT / incl. Grille (kg) 19 (22.7) 19 (22.7) 19 (22.7) 20 (23.7) 24 (29) 30 (35) 30 (35)DIMENSIONS Width 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950)(Grille) Depth 660 (760) 660 (760) 660 (760) 660 (760) 840 (950) 840 (950) 840 (950)

Height** 298 (30) 298 (30) 298 (30) 298 (30) 258 (30) 298 (30) 298 (30)PIPE SIZE ø (mm) liquid 6 6 6 10 10 10 10

gas 12 12 16 16 16 18 18ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz,1INPUT POWER (kW) 0.13 0.13 0.14 0.15 0.18 0.3 0.34RUNNING CURRENT (A) 0.6 0.6 0.64 0.68 0.86 1.43 1.64

* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber** Needed installation height, in brackets: Visible grille height

* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber** Needed installation height, in brackets: Visible grille height

* The values given in the table for the noise level reflect the measured at a position 1.5 m below the unit in anechoic chamber** Needed installation height, in brackets: Visible grille height

Page 85: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

85

PCFY SUSPENDED INDOOR UNITSPCFY- PCFY- PCFY- PCFY-MODEL REFERENCE P40VGM-A P63VGM-A P100VGM-A P125VGM-A

CAPACITY (kW) Cooling 4.5 7.1 11.2 14.0Heating 5.0 8.0 12.5 16.0

AIRFLOW (m3/h) Low 480 720 1080 1560Middle 1 600 840 1200 1680Middle 2 660 960 1380 1920High 720 1080 1500 2100

NOISE* dB(A) 29 / 38 32 / 39 36 / 43 37 / 44(Low/High)

WEIGHT (kg) 27 34 37 43DIMENSIONS (mm) Width 1000 1310 1310 1620

Depth 680 680 680 680Hight 210 210 270 270

PIPE SIZE ø (mm) liquid 6 10 10 10gas 12 16 18 18

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.10 0.13 0.16 0.24RUNNING CURRENT (A) 0.46 0.6 0.73 1.1

PKFY WALL MOUNTED INDOOR UNITSMODEL REFERENCE PKFY-P20VAM-A PKFY-P25VAM-A PKFY-P32VGM-A PKFY-P40VGM-A PKFY-P50VGM-ACAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6

Heating 2.5 3.2 4.0 5.0 6.3AIRFLOW (m3/h) Low 294 294 480 480 540

Middle 1 312 312 570 570 600Middle 2 336 336 630 630 660High 354 354 690 690 720

NOISE* dB(A) 32 / 36 32 / 36 33 / 41 33 / 41 34 / 43(Low/High)WEIGHT (kg) 8.5 8.5 16 16 16DIMENSIONS (mm) Width 815 815 990 990 990

Depth 158 158 235 235 235Height 295 295 340 340 340

PIPE SIZE ø (mm) liquid 6 6 6 6 10gas 12 12 12 12 16

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.04 0.04 0.07 0.07 0.07RUNNING CURRENT (A) 0.2 0.2 0.32 0.32 0.32

*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber

*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m below the unit in anechoic chamber

Page 86: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

86

Indoor Units - Technical Data

PEFY CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, VML WITH FILTER AS STANDARDPEFY- PEFY- PEFY- PEFY- PEFY- PEFY- PEFY-MODEL REFERENCE P20VML-A P25VML-A P32VML-A P40VMH-A P50VMH-A P63VMH-A P71 VMH-A

CAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 8.0Heating 2.5 3.2 4.0 5.0 6.3 8.0 9.0

AIRFLOW (m3/h) Low 324 324 360 600 600 810 930Middle 390 390 450 – – – –High 474 474 570 840 840 1140 1320

EXT. STATIC PRESSURE (Pa) 5 5 5 50 / 100 /150 / 200NOISE* (Low/High) dB(A) 29/36 29/36 30/40 27/34 27/34 32/38 32/39WEIGHT (kg) 18 18 18 44 44 45 50DIMENSIONS (mm) Width 720 720 720 750 750 750 1000

Depth 550 550 550 900 900 900 900Hight 225 225 225 380 380 380 380

PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 10gas 12 12 12 12 16 16 16

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.05 0.05 0.07 0.19 0.19 0.24 0.26RUNNING CURRENT (A) 0.24 0.24 0.32 0.88 0.88 1.12 1.20

PEFY CEILING CONCEALED DUCTED (REAR SUCTION) INDOOR UNITSPEFY- PEFY- PEFY- PEFY- PEFY- PEFY-MODEL REFERENCE P80VMH-A P100VMH-A P125VMH-A P140VMH-A** P200VMH-A** P250 VMH-A**

CAPACITY (kW) Cooling 9.0 11.2 14.0 16.0 22.4 28.0 Heating 10.0 12.5 16.0 18.0 25.0 31.5

AIRFLOW (Low/High) (m3/h) 1080/1500 1590/2280 1590/2280 1680/2400 3480 4320EXT. STATIC PRESSURE (Pa)

50/100/150/200 100/130/220/260

NOISE* (Low/High) dB(A) 35/41 34/42 34/42 34/42 45*** 52***WEIGHT (kg) 50 70 70 70 100 100DIMENSIONS (mm) Width 1000 1200 1200 1200 1250 1250

Depth 900 900 900 900 1120 1120 Hight 380 380 380 380 470 470

PIPE SIZE ø (mm) liquid 10 10 10 10 12 12gas 16 18 18 18 28 28

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1 380-415V, 50Hz, 3INPUT POWER (kW) (kW) 0.32 0.48 0.48 0.48 0.99 1.23RUNNING CURRENT (A) 1.47 2.34 2.34 2.35 1.62 2.00

***The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber*** Refering to projects. Please ask for delivery times.*** at 220 PA

*The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber

PEFY CEILING CONCEALED DUCTED (REAR OR BOTTOM SUCTION) INDOOR UNITS, FILTER AS STANDARDPEFY- PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - PEFY - PEFY -

MODEL REFERENCE P20VMM-A P25VMM-A P32VMM-A P40VMM-A P50VMM-A P63VMM-A P71VMM-A P80VMM-A P100VMM-A P125VMM-A P140VMM-ACAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0Heizleistung Heating 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0AIRFLOW(m3/h) Low 360 360 450 600 720 810 870 870 1380 1440 1770

Middle 432 432 540 720 870 972 1080 1080 – – –High 510 510 630 840 1020 1440 1260 1260 1980 2040 2520

EXT. STATIC PRESSURE (Pa) 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 30/50/100 50/130 50/130 50/130NOISE* (Low/High) dB(A) 27 / 32 27 / 32 28 / 35 31 / 37 31 / 38 31 / 38 32 / 39 32 / 39 40 / 44 42 / 45 42 / 45WEIGHT (kg) 27 27 27 33 33 42 42 42 62 65 70DIMENSIONS (mm) Width 815 815 815 935 935 1175 1175 1175 1415 1415 1715

Depth 700 700 700 700 700 700 700 700 740 740 740Hight 295 295 295 295 295 295 295 295 325 325 325

PIPE SIZE ø (mm) liquid 6 6 6 6 10 10 10 10 10 10 10gas 12 12 12 12 16 16 16 16 18 18 18

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.15 0.15 0.17 0.19 0.2 0.22 0.25 0.17 0.29 0.4 0.42RUNNING CURRENT (A) 0.73 0.73 0.81 0.92 0.98 1.07 1.15 0.82 1.31 1.9 1.95

Page 87: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

87

*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber

PFFY FLOOR STANDING (CONCEALED TYPE) INDOOR UNITSPFFY- PFFY- PFFY- PFFY- PFFY- PFFY-MODEL REFERENCE P20VLRM-A P25VLRM-A P32VLRM-A P40VLRM-A P50VLRM-A P63VLRM-A

CAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6 7.1Heating 2.5 3.2 4.0 5.0 6.3 8.0

AIRFLOW (m3/h) 330/390 330/390 420/540 540/660 720/840 720/930(Low/High)

NOISE* dB(A) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43(Low/High)

WEIGHT (kg) 18.5 18.5 20 21 25 27DIMENSIONS (mm) Width 886 886 1006 1006 1246 1246

Depth 220 220 220 220 220 220Height 639 639 639 639 639 639

PIPE SIZE ø (mm) liquid 6 6 6 6 10 10gas 12 12 12 12 16 16

ELECTRICAL SUPPLY (V, Freq., Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.04 0.04 0.06 0.065 0.085 0.1RUNNING CURRENT (A) 0.19 0.19 0.29 0.32 0.40 0.46

PFFY FLOOR STANDING (CABINET TYPE) INDOOR UNITSPFFY- PFFY- PFFY- PFFY- PFFY- PFFY-MODEL REFERENCE P20VLEM-A P25VLEM-A P32VLEM-A P40VLEM-A P50VLEM-A P63VLEM-A

CAPACITY (kW) Cooling 2.2 2.8 3.6 4.5 5.6 7.1Heizleistung Heating 2.5 3.2 4.0 5.0 6.3 8.0AIRFLOW (m3/h) 330/390 330/390 420/540 540/660 720/840 720/930(Low/High)

NOISE* dB(A) 31 / 37 31 / 37 32 / 37 35 / 40 35 / 40 37 / 43(Low/High)

WEIGHT (kg) 23 23 25 26 30 32DIMENSIONS (mm) Width 1050 1050 1170 1170 1410 1410

Depth 220 220 220 220 220 220Height 630 630 630 630 630 630

PIPE SIZE ø (mm) liquid 6 6 6 6 10 10Anschlüsse, außen ø (mm) gas 12 12 12 12 16 16

ELECTRICAL SUPPLY (V, Freq.,Phase) 220-240V, 50Hz, 1INPUT POWER (kW) 0.04 0.04 0.06 0.065 0.085 0.1RUNNING CURRENT (A) 0.19 0.19 0.29 0.32 0.40 0.46

*The values given in the table for the noise reflect the levels measured at a position 1 m in front of and 1 m above the unit in anechoic chamber

Page 88: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

88

City MultiSystem Control – Standard Remote Control

PAR-20MAA

Exposed type

Operatingstatus readout

PAC-SE51 CRAPAC-YT51 CRA*

PAR-F27 MEA

● PAR-20 MAA to connect at the indoor unit, building of groups of seperateDatabus System possible

● 1 Indoor unit individual, 1 Group with 16 indoor units possible by two-wiresignal lines

● Easy to read, easy to operate display● On/Off Timer● Temperature selection in 1°C units● Auto-diagnosis display

A microcomputer constantly monitors operation to keep the units runningsmoothly. Should problems occure, the temperature setting display changes toan auto-diagnosis display that shows the inspection mode and the unit addressalternately.

● Room thermometer is built into the remote controller.Switching possible to indoor unit room thermometer.

● PAR-F27 MEA to connect at the City Multi Databus System, easy to formgroups

● 1 Indoor unit individual / 1 Group with16 indoor units● Easy to read, easy to operate display● Extensive time function● Temperature selection in 1°C units● Auto-diagnosis display

A microcomputer constantly monitors operation to keep the units runningsmoothly. Should problems occure, the temperature setting display changes toan auto-diagnosis display that shows the inspection mode and the unit addressalternately.

● Room thermometer is built into the remote controller.Switching possible to indoor unit room thermometer.

● Limit temperature setting

● To simplify operation of the system, the range of controls has been limitedto START/STOP, room temperature and fan speed

● The only wiring required is cross-over wiring based on two-wire signal lines ● Room temperature sensors are built-in

The indoor unit can be replaced with body thermostats ● Easy-to-read, easy-to-operate icon display● Temperature selection● Can operate all types of indoor units● Standardized remote controllers for all indoor units● 1 indoor unit individual/1 group with 16 indoor units● PAC-SE51 CRA – Grouping addressing by data bus● PAC-YT51 CRA – Main grouping by two-wire signal lines

*Since this system has no operation mode switching, test operation, self-diagnosis or linkedsetting functions, it should always be used in conjunction with the PAR-F27MEA or othercentralized controller.

Page 89: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

89

City Multi System Control Accessories – Infrared-, Group- and

System Remote Control – Timer

Infrared-Remote Control PAR-FL31 MA andPAR-FA31 MA (Signal receiver)

● It can operate in a group system without requiring address settings

● When operating, it displays LED lamps. When errors occure, the error can be shown by the LED flash count

● 1 Indoor unit individual/1 group with 16 indoor unitsby two-wire signal lines

Group Remote Control PAC-SC30 GRA

● Easy to read, easy to operate display● Temperature selection in 1°C units● Auto-diagnosis-display

A microcomputer constantly monitors operation to keep the units runningsmoothly. Should problems occure, the temperature setting display changes toan auto-diagnosis display that shows the inspection mode and the unit addressalternately.

● 8 Indoor units individual / Max. 16 Indoor units in 8 groups

Programme Timer PAC-YT32 PTA

● One-week scheduling by remote controller● Set-back function● Control for PAR-F27 MEA

(1 Indoor unit individual / 1 group with 16 indoor units)

PAC-SC30GRA

PAR-FL31MA

PAR-FA31MA

PAC-YT32 PTA

Page 90: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

90

City Multi System Control Accessories – Infrared-, Group- and

System Remote Control – Timer

On/Off Remote Controller PAC-YT40 ANRA

● Up to 50 groups● Price competitive solution,

up to 50 indoor units

System Remote Controller PAC-SF44 SRA

● Control range as Standard Controller (Air Outlet Angle/Air Filter)● Limited room air temperature selection● Auto diagnosis system● 50 indoor units individual/max. 50 indoor units with 50 groups● Lock-out function for PAR-F27 MEA● External Input/Output

System Timer PAC-YT34 STA

● Directly connected to the M-Net databus● 50 groups/max. 50 indoor units● Timer-controlled mode● Timer-controlled temperature● 9 Timer functions● Lock-off selection (On/Off/Mode/Temperatue)

PAC-YT40 ANRA

PAC-YT34 STA

PAC-SF44SRA

Page 91: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

91

City Multi The New Controller G-50 A– The Next Controller Generation

● Simple and flexibleThe central controller G-50 A is equally suitable for small and large systems.

● Web browserUse a standard web browser on your PC, e.g. Microsoft Internet ExplorerTM, to operate and monitor the air-conditioning unit, which is connected to your localIntranet, in comfort.

● Integrated softwareThe easy to understand operating software is already integrated in the G-50 A.This represents Mitsubishi Electric’s own innovation and is not Windows-based.It is therefore impossible for hackers to spy in your system data.

● Three password levelsYou can safeguard against unauthorised access to the air-conditioning systemon three operating levels which are individually protected by passwords of yourchoice. – Access to an air-conditioning unit (or group) e.g. for each office/floor but

without the possibility to change the system settings– Access to group and maintenance functions, e.g. for in-house technicians– Access to the entire system, e.g. for the system administrator

● Remote accessYou can also operate your air-conditioning system with your PC by remote control via your local intranet or phone connection. The access is protected by a password of your choice.

● Automatic alarmIf an error occurs, the G-50 A sends a message with the most important information to a mobile phone (SMS) or an email to an address of your choice.

● Always up-to-dateUpgrades with continuously updated special functions are available for the G-50 A.Examples: – Energy consumption data for individual cost statements

– Special economy programmes– Annual schedules

G-50A

HARDWARE FOR G-50APos. Type Description

1 G-50A - Standard Standard central controller for 50 air conditioners2 G-50A - Pro As above G-50 incl. Web function & annual schedule, programmed for clients demand3 PAC-SC 50 KUA Power supply unit for G-504 BTX-1000 Router according to ME specification & installation is required depending to clients demands5 PC* with software TG 2000 PC according Me specification & installation with OS, Internet Explorer and software TG 20006 Watt Hour Meter Amount of WHM is depend of the project

SOFTWARE FOR G-50AWeb Function Set free HomepagePersonal Web RC Remote Control via PCPower consumption Ratio Calculate individual cost***Demand Control I Limit temperature range, optimize indoor-outdoor unit**Demand Control II Peak Cut*** only connection with PLC + PLC SoftwareAnnual Schedule Weekly and Yearly Timer**Data Export Trend Graph***Error scanning function Monitoring Error HistoryAuto Alarming Auto Alarm function – Error Code mailingService Maintenance Tool functionBACnet BACnet ConnectionPLC PLC connection direct with G-50 via RJ45

TG 2000 Installation TG 2000 software according customer requirement

* Computer periphery like Monitor, Keyboard, Mouse, Printer from client** Operation with G-50 or Pos. 5*** Additional pos. 5 nessassary, for Power consumption ration additional Pos. 6 nessassary

Page 92: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

92

City Multi – Central Remote Control– LonWorks® Interface– Maintenance Tool

Lon Works®-Interface

● Easy connection of City Multi Systems through LMAP02-E, the LonWorks®-M-Net protocol converter, the total system requirements of engineers and end-users can be met more effectively and simply.

● 1 Lon Works®-Interface manages 50 indoor units.L-MAP02-E

Maintenance Tool - CMS-MNF-B

● Using Maintenance Tool is the easiest way forcontrolling, servicing and operating the City Multisystem. All system information will be displayedon personal computer* screen based on WindowsSoftware and settings can be changed.

● In addition, error code numbers are output ontothe display.

● Easy maintenance is assured through the troublehistory printer output and call functions. Besidesths connection with modem and data transfer ispossible. CMS-MNF-B consists of converter boxand software, RS-232 cable (cross) is needed.

* Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, free space 10 MB on HDD.

Page 93: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

93

City Multi Accessories

*you can use also Standard T-Branch

CONTROLSMODEL REFERENCE DESCRIPTIONPAC-SF48MA-E A to M-Net transmission converterPAC-SE40TS-E Temperature sensorPAC-725AD Remote indicator (Pack of 10)PAC-SA88HA-E Remote indicator (Pack of 1)PAC-SF46EPA Transmission booster

ACCESSORIESMODEL REFERENCE DESCRIPTIONPLFY-P-VKM/VAM-APAC-SE06WP-E Wide panel for PLFY-P32/40/50/63 VKM-APAC-SE01AS-E Space panel for PLFY-P32/40/50/63 VKM-APAC-SE60AS-E Space panel for PLFY-P80/100/125 VAM-A

PAC-SE13FK-E High efficiency filter for PAC-SE21TM-EPAC-SG01KF High efficiency filter for PAC-SG03TM-E

PAC-SE21TM-E Multifunction casement for PLFY-P32/40/50/63 VKM-APAC-SG03TM-E Multifunction casement for PLFY-P80/100/125 VAM-A

PCFY-P-VGM-APAC-SE80KF-E High efficiency filter for PCFY-P40 VGM-APAC-SE81KF-E High efficiency filter for PCFY-P63/100 VGM-APAC-SE82KF-E High efficiency filter for PCFY-P125 VGM-A

PAC-SE84DM-E Drain pump for PCFY-P40 VGM-APAC-SE85DM-E Drain pump for PCFY-P63 VGM-APAC-SE86DM-E Drain pump for PCFY-P100/125 VGM-A

PEFY-P-VML/VMH-APAC-KE04DM-F Drain pump for PEFY-P-VMH-APAC-KE32LAF-F Replacement filter for PEFY-P20/25/32 VMLPAC-KE86LAF Optional filter for PEFY-P40/50/63 VMHPAC-KE88LAF Optional filter for PEFY-P71/80 VMHPAC-KE89LAF Optional filter for PEFY-P100/125/140 VMHPAC-KE85LAF Optional filter for PEFY-P200/250 VMHPAC-KE63TB-F Filter box for PEFY-P40/50/63 VMHPAC-KE80TB-F Filter box for PEFY-P71/80PAC-KE140TB-F Filter box for PEFY-P100/125/140PAC-KE250TB-F Filter box for PEFY-P200/250

PEFY-P-VMM-APAC-KE03DM-F Drain pump for PEFY-P-VMM-APAC-KE32EDF-F Round duct flange for PEFY-P20/25/32 VMM-APAC-KE50EDF-F Round duct flange for PEFY-P40/50 VMM-APAC-KE80EDF-F Round duct flange for PEFY-P63/71/80 VMM-APAC-KE125EDF-F Round duct flange for PEFY-P100/125 VMM-APAC-KE140EDF-F Round duct flange for PEFY-P140 VMM-A

PU(H)Y-P/PURY-P-YMF-B/CPAC-KBU02MT-F High static pressure motor, 30 PA for PU(H)Y-/PURY-

P200/250 YMF-CPAC-KBU03MT-F High static pressure motor, (30) 60 PA for PU(H)Y-/PURY-

P200/250/315 YEM-A

REFRIGERANT PIPESCMY-R160-H Junction pipe kit for BC-ControllerCMY-R160-HA Junction pipe kit for BC-Controller 2 x CMY-R160-HCMY-Y102S-F* Joint for capacity 160 or belowCMY-Y102L-F* Joint for capacity from 161 up to 330CMY-Y202-F* Joint for capacity from 331 up to630CMY-Y302-F* Joint for capacity 631 or aboveCMY-Y104-F* Header (4 branch)CMY-Y107-F* Header (7 branch)CMY-Y1010-F* Header (10 branch)CMC-30A Super Y Kit

Page 94: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

94

The sophisticated heat recovery technology of the Lossnay Element saves energy even while keeping yourroom comfortable.The simultaneous intake/exhaust of air together withthe Lossnay core recovers temperature and humidityfrom the room. The system’s benefit is to use thereleased cooling or heating energy for fresh airconditioning.

Lossnay Ventilation Systemswith heat recoveryVL-Series/LGH-Series

Page 95: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

• Ventilation without wasting energyVentilation of buildings can waste considerable amounts of heating or cooling energy. The Lossnay system can utilise a highpercentage of this energy to cut operating costs between 20%and 50% of the power what would otherwise be required to maintain a constant temperature.

• Save capital costs tooBy utilising this lost energy, the capacity of installed heating andcooling systems can also be reduced, with a consequent savingin capital costs of up to 30%. Lossnay units are designed tokeep exhaust air and fresh air completely separate and yet stillachieve an efficiency in the range of 60% to 70%. The fresh airthen enters the room at a similar temperature to be expelled air,to provide comfortable environmental conditions all year round.

• Lossnay at work - and at homeLossnay total heat exchange ventilators are available in rangesfor both commercial installations and residential use.

Renewedinternal air

Stale internalair recovery

Outside air is drawn in

Stale air expelled outside

Operating range Lossnay systemVL-Series: t = -10°C bis 40°C, ϕ = 60% maxLGH-Series: t = -10°C bis 40°C, ϕ = 80% max

LOSSNAY HEAT EXCHANGE SYSTEM

95

Page 96: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

96

Lossnay VL-Series Wall Mounted SystemsModel VL-100

Lossnay LGH-Series Ceiling Suspended SystemsModel LGH-40ES-E

To install the units of the Lossnay Series VL-100only 2 x 75 mm diameter bores are necessary.Supply and return air ducts and protective capsagainst invading rain water are included in delivery.The units operate very quietly, selection between2 fan speed levels is possible, the unit will be switchedon/off by pull string.

* The values given in the table for the noise level reflect the levels measured at a position 1 m infront of and 0.8 m below the unit in anechoic chamber

* The values given in the table for the noise level reflect the levels measured at aposition 1 m in front of and 0.8 m below the unit in anechoic chamber

• Compact DesignA mere 255 mm from front to back, this thin design takesup a minimum of space even when suspended from theceiling of an existing building.

• Minimal installation needsIn addition to this lightweight and compact design, connection to the outdoor unit requires just a 200 mm.

• Saves energyThe simultaneous intake/exhaust of air together with theLossnay core recovers temperature and humidity from theroom while ventilating, making this unit both economicaland environmentally friendly.

• A refined designDesigned to eliminate the outflow of air to the space directly beneath the unit, there is no worry of discomfortfrom drafts.

LOSSNAY-LGH-SERIESMODEL REFERENCE LGH-40ES-E

ELECTRICAL SUPPLY 220-240, 1, 50(V, PHASE,HZ)

POWER INPUT (W) low 88high 138

RUNNING CURRENT (A) low 0.4high 0.6

AIRFLOW (m3/h) low 250high 400

STATIC PRESSURE (Pa) low 10high 40

NOISE* dB(A) low 33high 42

TEMPERATURE RECOVERY low 70(%) EFFICIENCY high 60

ENTHALPY RECOVERY low 52(%) EFFICIENCY high 45

WEIGHT (kg) 25

DIMENSIONS (mm) WIDTH 900DEPTH 693HEIGHT 255

DUCT SIZE (mm) 2 x 200 ø

OPTIONAL PARTSMODEL REFERENCEPZ-03SLP-E Switch ON/OFF and Airflow

LOSSNAY-VL-SERIESMODEL REFERENCE VL-100U-EELECTRICAL SUPPLY

220-240, 1, 50(V, PHASE,Hz)POWER INPUT (W) Low 23

High 26AIRFLOW Low 65(m3/h) High 105NOISE* Low 29.5dB(A) High 39EFFICIENCY (%) Low 77

High 70WEIGHT (kg) 6.5DIMENSIONS (mm) Width 620

Depth 168Height 265

DUCT SIZE (mm) 2x75ø

Page 97: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

Lossnay LGH-Commercial SeriesModels LGH-15 to 200 RX

● Saves between 20% and 50% of the energy that would otherwise be lost by ventilation

● Saves up to 30% on initial capital costs of heating and cooling plant due to Lossnay’s ability to utilise heating or cooling energy that would otherwise be wasted

● Automatically humidifies or dehumidifies incoming air to match required interior conditions

● Supply air and exhaust air are kept strictly separated to ensure inbound air is always fresh

● Supply air is heated or cooled as required to match room conditions

● Provides comfortable ventilation through introduction of fresh air, helping to provide a healthy working environment

● Minimal Maintenance● Easily replaced Lossnay element

ACCESSORIES LOSSNAYMODEL REFERENCE DESCRIPTIONPZ-41SLB WIRED REMOTE Control for independent operationPZ-52SF Remote Controller for City Multi System

LOSSNAY-LGH-SERIESMODEL REFERENCE LGH15RX LGH25RX LGH35RX LGH50RX LGH80RX LGH100RX LGH150RX LGH200RXELECTRICAL SUPPLY

220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50(V,PHASE,Hz)RUNNING CURRENT (A) 0.52 0.55 0.82 0.96 1.8 2.3 3.3 4.6POWER INPUT (W) Low 52 54 97 123 304 465 585 900

Medium 74 91 154 193 368 495 670 995High*** 104 111 169 204 392 500 720 1000

AIRFLOW Low 120 165 230 350 670 870 1200 1400(m3/h) Medium 150 250 350 500 800 1000 1500 2000

High*** 150 250 350 500 800 1000 1500 2000STATIC PRESSURE (Pa)* Low 25 20 25 30 70 80 50 83

Medium 40 40 70 60 100 100 100 80High*** 90 65 150 150 140 160 137 137

NOISE** Low 21 21 23 24 30 32 33 36dB(A) Medium 24 25 28 30 32 34 36 37

High*** 26 27 31 32 34 36 37 39EFFICIENCY % Low 80 93 84 82 81 81 81 83

Medium 77 78 79 77 78 79 79 79High*** 77 78 79 77 78 79 79 79

WEIGHT (kg) 19 23 33 38 73 83 175 194DIMENSIONS (mm) Width 610 735 874 1016 1004 1221 1004 1231

Depth 780 780 888 888 1164 1164 1662 1662Height 275 275 317 317 398 398 800 800

DUCT SIZE (mm) 100ø 150ø 150ø 200ø 250ø 250ø 350ø 350ø

*** Refering to the airflow in the table*** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber*** Extra high ventilation step to increase stat. pressure

97

Page 98: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

9898

MJ-E16PX Dehumidifier

• Easy to operate by LCD display

• 3 operating modes: low,high and auto

• Large water container (6 L)

• Automatic stop by overflowprotection

• Timer: 1 – 9 hours operation

• Air filter

• Display of defrost

• Waterlevel visible

• Hygrostat

• Display of humidity(50%, 60%, 70%)

• Automatic restart after voltage break

• Collects up to 16 litres of moisture in a 24 hoursperiod

• Compact, unobstrusive andquiet in operation

• Low energy consumption

• Environment-friendlyrefrigerant R134a

Compact and efficient

MJ-E16PX seems unobstrusive and is portable because of its grip and weight (12.9 kg).

Additional Advantages

• Reduces the time of drying your clothes onthe line

• Installation of a hose possible to transport the condensate water

MJ-E16PXDEHUMIDIFYING CAPACITYLitres/24 hours 10°C/70% rel. humidity 3.1

27°C/60% rel. humidity 9.030°C/80% rel. humidity 16.0

TECHNICAL DATAWater container (I) 5.0Auto Stop (I) 5.0Weight (kg) 12.9Dimensions (mm) Width 360

Depth 281Height 569

Supply voltage (V, Phase, Hz) 220-240, 1, 50Power consumption (W) 280Noise dB(A) Low 33in fan operation High 35Operating temperature min. 1°C

max. 40°CCompressor type RotaryRefrigerant R134 aColour white

MJ-E16PXCONTROL FUNCTIONSMode button selects low, high and autoTimer button press to set operation time

1 – 9 hours or permanentControl lamp shows adjustmentTank full lamp lights when water tank

needs emptyingDefrost lamp light is on during

defrost operationHumidity lamp lights when extremely high

rel. humidity, audible signal forrel. humidity more than 70%

Page 99: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW
Page 100: Air Conditioning Program R 407C R · PDF fileSound pressure level measured in anechoic ... in front of and 0.8 m below the unit in anechoic chamber. 7 ... Heating 5.2 7.2 9.4 AIRFLOW

Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B. V.The Company reserves the right to make any variation in specification to the equipment described or to withdraw orreplace products without prior notification or public announcement. Mitsubishi Electric is constantly developing andimproving its products. All descriptions, illustrations, drawings and specifications in this publication present only generalparticulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Condi-tions of Sale, a copy of which is available on request.

Art. No. 154384 © 05/2004

MITSUBISHI ELECTRIC EUROPE B.V.AIR CONDITIONING DIVISIONGOTHAER STR. 8D-40880 RATINGENGERMANY

TEL.: +49-2102-486-1800FAX: +49-2102-486-7910

www.mitsubishi-electric-aircon.de