AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

8
AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

Transcript of AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

Page 1: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

..L

AIR CONDITIONING &HEAT PUMP PRODUCTS

SEER 17

Page 2: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

SEER 17 / R-410A

Compressor

Indoor UnitOutdoor Unit

AS-12UR1SVEDJ AS-12TR1SVEDJModelsType T1, INVERTER T1, INVERTERCooling Capacity Btu/h 12000 12000 Heating Capacity Btu/h 13000 NoCooling Capacity Range Btu/h 2500-13500 2500-13500Heating Capacity Range Btu/h 2500-14500 NoPower Input-Cooling W 1200 1200 Power Input-Heating W 1200 NoSEER Cooling 17.9 18.4 HSPF Heatling 9.4 NoEER for Cooling Btu/W 10.00 10.00 COP for Heating Btu/W 10.83 NoMoisture Removal L/H.r 1.2 1.2 Refrigerant Type R410A R410AIndoor Sound Pressure (S/H/M/L) dB (A) 40/36/33/26 40/36/33/26Outdoor Sound pressure (H) dB (A) 54 54 Airflow Indoor Unit (S/H/M/L) m3/h 700/645/596/469 700/645/596/469Airflow Indoor Unit (S/H/M/L) CFM 416/384/355/279 416/384/355/279Airflow Outdoor Unit (H) m3/h 1600 1600Airflow Outdoor Unit (H) CFM 952 952 Voltage, Frequency, Phase V 115V~,60Hz,1P 115V~,60Hz,1P

Current input Cooling (A) 10.8 10.8

Heating (A) 10.8 No

Current Range Cooling (A) 2.5-15 2.5-15

Heating (A) 2.5-15 No

Compressor Type Rotary Rotary

MFG GMCC GMCCIndoor motor speed H/M/L 1250/1100/950 1250/1100/950Outdoor motor speed H/M/L 850/600/450 850/600/450Liquid Pipe inch 1/4 1/4Gas Pipe inch 3/8 3/8

AIR CONDITIONING Cooling Heating Cooling Only

Page 3: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

Net Dimensions (WxHxD) Indoor Unit mm 815×270×214 815×270×214

inch 32 1/16x10 5/8x8 7/16 32 1/16x10 5/8x8 7/16

Net Dimensions (WxHxD) Outdoor Unit mm 715×482×240 715×482×240

inch 28 1/8x19x9 7/16 28 1/8x19x9 7/16Net Weight - Indoor Unit Kg 9.0 9.0 Net Weight - Outdoor Unit Kg 27.0 26.5

Packing Dimensions (WxHxD) Indoor Unit mm 870×335×265 870×335×265

inch 34 1/4x13 3/16x10 7/16 34 1/4x13 3/16x10 7/16

Packing Dimensions (WxHxD) Outdoor Unit mm 830×530×340 830×530×340

inch 32 11/16x20 7/8x13 3/8 32 11/16x20 7/8x13 3/8Gross Weight - Indoor Unit Kg 11.0 11.0 Gross Weight - Outdoor Unit Kg 30 29 Test Standard ARI 210-240 ARI 210-240Approvals ETL/AHRI ETL/AHRILED Display on Front Panel Yes YesLED Dimmer Yes Yes7 Indoor Fan Speed Yes YesLCD Wireless Remote Controller Yes Yes"I feel" in remote controller Yes YesBack lighting remote controller Yes Yes-20°C (-4°F) Heating Yes NoWorking Temperature Range - Cooling (°C/°F) -15℃-46℃;(5℉-115℉) -15℃-46℃;(5℉-115℉) Working Temperature Range - Heating (°C/°F) -20℃-24℃;(-4℉-75℉) No8°C (46°F) Heating to avoid freezing water pipe in Kitchen Yes No°C & °F convertible Yes Yes2 Ways Draining Connection (Left or Right) Yes YesCompressor Intelligent Pre-heating Yes NoSmart Function Yes YesSuper Function Yes YesAuto Restart Yes YesAuto Defrost Yes YesAuto Cleaning Yes YesQuiet Mode Yes Yes24 Hours Timer Yes YesRemovable and washable Panel Yes YesLouver Postion Memory Yes YesWashable High Definition Filter Yes YesHorizontal Auto Swing Louver Yes YesChassis Electric heater function Yes No

SEER 17 / R-410A

Indoor UnitOutdoor Unit

AS-12UR1SVEDJ AS-12TR1SVEDJModels

Compressor

AIR CONDITIONING Cooling Heating Cooling Only

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

Page 4: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

SEER 17 / R-410A

Compressor

AS-18UR3SXADJ AS-18TR3SXADJModels

Indoor UnitOutdoor Unit

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

Type T1, INVERTER T1, INVERTERCooling Capacity Btu/h 18,000 18000 Heating Capacity Btu/h 20,000 NoCooling Capacity Range Btu/h 6500-19500 6500-19500Heating Capacity Range Btu/h 6000-21500 NoRated Input-Cooling W 1700 1700 Rated Input-Heating W 2000 NoSEER Cooling 17.6 18.3 HSPF Heatling 10.1 NoEER for Cooling Btu/W 10.59 10.59 COP for Heating Btu/W 10.00 NoMoisture Removal L/H.r 2.0 2.0 Refrigerant Type R410A R410ARefrigerant charge volume g 1400 1350 Indoor Sound Pressure (S/H/M/L) dB (A) 45/43/38/35 45/43/38/35Outdoor Sound pressure (H) dB (A) 56 56 Airflow Indoor Unit (S/H/M/L) m3/h 1005/901/750/580 1005/901/750/580Airflow Indoor Unit (S/H/M/L) CFM 598/536/446/345 598/536/446/345Airflow Outdoor Unit (H) m3/h 2000 2000Airflow Outdoor Unit (H) CFM 1190 1190Voltage, Frequency, Phase V 208/230V~,60Hz,1P 208/230V~,60Hz,1P

Rated Current Cooling (A) 7.6 7.6

Heating (A) 9.0 No

Current Range Cooling (A) 1.8-12 1.8-12

Heating (A) 1.8-12 No

Compressor Type Rotary Rotary

MFG GMCC GMCCIndoor motor power output W 35 35Indoor motor speed H/M/L 1150/990/830 1150/990/830Outdoor motor speed H/M/L 910 910Evaporator material, Tube outside dia.and type

mm Ф7,innergroove tube Ф7,innergroove tube

Condenser material, Tube outside dia.and type

mm φ7 innergroove tube φ7 innergroove tube

AIR CONDITIONING Cooling Heating Cooling Only

Page 5: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

..I 1

Connecting Pipe Diameter, Liquid Pipe inch 1/4 1/4Connecting Pipe Diameter, Gas Pipe inch 1/2 1/2

Net Dimensions (WxHxD) Indoor Unit mm 915×315×236� 915×315×236�

inch 36x12 3/8x9 5/16 36x12 3/8x9 5/16

Net Dimensions (WxHxD) Outdoor Unit mm 810x585x280 810x585x280

inch 31 7/8x23x11 31 7/8x23x11Net Weight Indoor Unit Kg 12.5 12.5 Net Weight Outdoor Unit Kg 39 38

Packing Dimensions (WxHxD) Indoor Unit mm 1000×390×315 1000×390×315

inch 39 3/8x15 3/8x12 3/8 39 3/8x15 3/8x12 3/8

Packing Dimensions (WxHxD) Indoor Unit mm 940x640x385 940x640x385

inch 37x25 3/16x15 3/16 37x25 3/16x15 3/16Gross Weight Indoor Unit Kg 14.5 14.5 Gross Weight Outdoor Unit Kg 42 41 Test Standard ARI 210-240 ARI 210-240Approvals ETL/AHRI ETL/AHRILED Display on Front Panel Yes YesLED Dimmer Yes Yes7 Indoor Fan Speed Yes YesLCD Wireless Remote Controller Yes Yes"I feel" in remote controller Yes YesBack lighting remote controller Yes YesWorking Temperature Range - Cooling (°C/°F) 0℃-46℃;(32℉-115℉) 0℃-46℃;(32℉-115℉)Working Temperature Range - Heating (°C/°F) -20℃-24℃;(-4℉-75℉) No8°C (46°F) Heating to avoid freezing water pipe in Kitchen Yes No°C & °F convertible Yes Yes2 Ways Draining Connection (Left or Right) Yes YesCompressor Intelligent Pre-heating Yes NoSmart Function Yes YesSuper Function Yes YesAuto Restart Yes YesAuto Defrost Yes YesAuto Cleaning Yes YesQuiet Mode Yes Yes24 Hours Timer Yes YesRemovable and washable Panel Yes YesLouver Postion Memory Yes YesWashable High Definition Filter Yes YesHorizontal Auto Swing Louver Yes YesChassis Electric heater function Yes No

AS-18UR3SXADJ AS-18TR3SXADJModels

SEER 17 / R-410A

Indoor UnitOutdoor Unit

AIR CONDITIONING Cooling Heating Cooling Only

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

Compressor

Page 6: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

SEER 17 / R-410A

Indoor UnitOutdoor Unit

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

Compressor

AIR CONDITIONING Cooling Heating

Type T1, INVERTERCooling Capacity Btu/h 24�000 Heating Capacity Btu/h 24�500 Cooling Capacity Range Btu/h 8000-26500Heating Capacity Range Btu/h 8000-26500Rated Input-Cooling W 2290 Rated Input-Heating W 2280 SEER Cooling 17,6 HSPF Heatling 9,8 EER for Cooling Btu/W 10,48 COP for Heating Btu/W 10,75 Moisture Removal L/H.r 2,4 Refrigerant Type R410ARefrigerant charge volume g 1630 Indoor Sound Pressure (S/H/M/L) dB (A) 48/45/40/36Outdoor Sound pressure (H) dB (A) 58 Airflow Indoor Unit (S/H/M/L) m3/h 1080/980/820/650Airflow Indoor Unit (S/H/M/L) CFM 643/583/488/387Airflow Outdoor Unit (H) m3/h 2800Airflow Outdoor Unit (H) CFM 1666 Voltage, Frequency, Phase V 208/230V~,60Hz,1P

Rated Current Cooling (A) 10,5

Heating (A) 10,4

Current Range Cooling (A) 2.0-13

Heating (A) 2.0-13Compressor Type RotaryCompressor MFG GMCCIndoor motor power output W 35Indoor motor speed H/M/L 1100/960/800Outdoor motor speed H/M/L 840Liquid Pipe inch 3/8Gas Pipe inch 5/8

Models AS-24UR3SBBDJ

Page 7: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

),~

SEER 17 / R-410A

Indoor UnitOutdoor Unit

A PARTICIPATINGCORPORATIONIN THE ARI AIRCONDITIONINGCERTIFICATIONPROGRAM

Compressor

Net Dimensions (WxHxD) Indoor Unit mm 1085×315×236

inch 42 3/4x12 3/8x9 5/16

Net Dimensions (WxHxD) Outdoor Unit mm 860x650x310

inch 33 7/8x25 9/16x12 3/16 Net Weight Indoor Unit Kg 15 Net Weight Outdoor Unit Kg 50

Packing Dimensions (WxHxD) Indoor Unit mm 1170×390×315

inch 46 1/16x15 3/8x12 7/16

Packing Dimensions (WxHxD) Outdoor Unit mm 995x730x445

inch 39 3/16x28 3/4x17 1/2Gross Weight Indoor Unit Kg 17,0 Gross Weight Outdoor Unit Kg 54,0 Test Standard ARI 210-240Approvals ETL/AHRILED Display on Front Panel YesLED Dimmer Yes7 Indoor Fan Speed YesLCD Wireless Remote Controller Yes"I feel" in remote controller YesBack lighting remote controller YesWorking Temperature Range - Cooling (°C/°F) 0℃-46℃; (32℉-115℉)Working Temperature Range - Heating (°C/°F) -20℃-24℃; (-4℉-75℉)8°C (46°F) Heating to avoid freezing water pipe in Kitchen Yes°C & °F convertible Yes2 Ways Draining Connection (Left or Right) YesCompressor Intelligent Pre-heating YesSmart Function YesSuper Function YesAuto Restart YesAuto Defrost YesAuto Cleaning YesQuiet Mode Yes24 Hours Timer YesRemovable and washable Panel YesLouver Postion Memory YesWashable High Definition Filter YesHorizontal Auto Swing Louver YesChassis Electric heater function Yes

AS-24UR3SBBDJModels

AIR CONDITIONING Cooling Heating

Page 8: AIR CONDITIONING & HEAT PUMP PRODUCTS - Distribution DWP

.,,.

Indoor Unit

Outdoor Unit