Air and Water-Resistive / Waterproofing Barrier Systems...
Transcript of Air and Water-Resistive / Waterproofing Barrier Systems...
Air and Water-Resistive / Waterproofing Barrier Systems
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
Installation Guidelines
Air and Water-Resistive/Waterproofing Barrier Systems
Step 1 Prepare• Reinforce and bridge Sheathing joint with Joint Fabric .........................................................4
• Fill and bridge sheathing joint with Joint & Seam Filler .........................................................5
• Reinforce and bridge rough opening preparation Joint Fabric and EZCorners ...........................6
• Fill and bridge rough opening preparation Joint & Seam Filler ...............................................7
• Fill, bridge and flash rough opening preparation Joint & Seam Filler & FastFlash ....................8
• CMU rough opening preparation with Joint & Seam Filler and FastFlash ..................................9
• Through-wall penetrations Joint & Seam Filler .......................................................................10
Step 2 Protect• Sheathing joint prepared with Joint Fabric, Spray Wrap, MVP or VB .....................................12
• Sheathing joint prepared with Joint & Seam Filler, Spray Wrap, MVP, VB or Cat-5 ..................13
• Rough Opening prepared with Joint & Seam Filler, Spray Wrap, MVP or VB ............................14
• Rough Opening prepared with Joint & Seam Filler/FastFlash, Spray Wrap, MVP, VB or Cat-5...15
• CMU Rough opening not previously treated ..........................................................................16
• CMU Rough opening prepared with Joint & Seam Filler/FastFlash ..........................................17
• Through-Wall Penetrations Joint & Seam Filler and Spray Wrap, MVP, VB or Cat-5 ..................18
Step 3 Transition• Parapet Termination using Spray Wrap, MVP, VB or Cat-5 .......................................................20
• CMU Control Joint with Transition Membrane and Spray Wrap, MVP, VB or Cat-5 ....................21
• Window Installation using AirDam .........................................................................................22
• Metal flashing Treatment using Joint Fabric ...........................................................................23
• Metal flashing Treatment using Joint & Seam Filler and FastFlash ...........................................24
• Brick Anchor Attachment .......................................................................................................25
• Termination at grade - Sheathing with Joint Fabric .................................................................26
• Termination at grade - Sheathing with Joint & Seam Filler and FastFlash ................................27
• StuccoPrime to receive stucco scratch coat ..............................................................................28
• Through-Wall Flashing on CMU ..............................................................................................29
• Through-Wall Flashing on Sheathing ......................................................................................30
• Through-Wall Flashing on Spandrel Construction ...................................................................31
Table of Contents
New Construction
Air and Water-Resistive/Waterproofing Barrier Systems
Step 1
To make a claim on PROSOCO’s R-GUARD warranties, you must meet all terms and conditions of the warranty, including use of the applicable R-GUARD Installation Guidelines. If a specific installation detail or technique is not covered, then the general principles outlined in the R-GUARD Installation Guidelines must have been followed. Contact PROSOCO with any questions regarding installation.
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime SheathingPROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 4
www.prosoco.com
Reinforce and bridgesheathing joint with Joint Fabric
Apply second coat of R-GUARD Spray Wrap, R-GUARD MVP or R-GUARD VB over Joint Fabric.
Spot overdriven screws.
PROSOCO R-GUARD®Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®Joint Fabric
Light weight structural members
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
embedded into a wet priming application of R-GUARD Spray Wrap, R-GUARD MVP or R-GUARD VB
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 5
www.prosoco.com
Fill and bridgesheathing joint with Joint & Seam Filler
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
Fille
r
Fill and bridge joints and seams up to 1/2”. Spread 1” beyond seam edge to a thickness of 20 - 30 mils.Spot overdriven screws.
PROSOCO R-GUARD®Joint & Seam Filler
Sheathing
Light weightstructural member
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 6
www.prosoco.com
Reinforce and bridgerough opening preparationJoint Fabric and EZCorners
Step E
Step FStep G
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
PROSOCO R-GUARD®
EZCorner
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
PROSOCO R-GUARD®
EZCorner
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
PROSOCO R-GUARD®
EZCorner
Step D
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
PROSOCO R-GUARD®
EZCorner
Step C
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
Step B
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
EZCorner
PROSOCO R-GUARD®
Joint Fabric
Step A
PROSOCOR-GUARD®
Spray Wrap, MVP or VB
Sheathing
PROSOCO R-GUARD®
Joint Fabric
R-GUARD Joint Fabric is applied in a shingle fashion with at least a 2” overlap
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 7
www.prosoco.com
Fill and bridgerough opening preparationJoint & Seam Filler
into all inside corners, cracks, open joints and seams in the rough opening and sheathed surfaces to a thickness of 20 - 30 mils.
PROSOCO R-GUARD®Joint & Seam Filler
Sheathing
Light weight structural members
PROSOCO R-GUARD®GypPrime
Sheathing
Light weight structural members
Fille
r
Consolideate and seal cut edges of gypsum board sheathing in rough openings with PROSOCO R-GUARD® GypPrime.
PROSOCO R-GUARD®Joint & Seam Filler
Fille
r
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 8
www.prosoco.com
Fill, bridge and flashrough opening preparationJoint & Seam Filler & FastFlash
1-inch beyond each seam edge to a thickness of 20 - 30 mils.
PROSOCO R-GUARD®Joint & Seam Filler
SheathingSupporting structure
PROSOCO R-GUARD®GypPrime
Fille
r
PROSOCO R-GUARD FastFlash over the inside of the rough opening and extending 4-6” over the face of the structural wall
PROSOCO R-GUARD®FastFlash
PROSOCO R-GUARD®Joint & Seam Filler
Fille
r
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 9
www.prosoco.com
CMU rough opening preparation with Joint & Seam Filler and FastFlash
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
PROSOCO R-GUARD®FastFlash4” - 6” onto wall
Spread one inch vertically andhorizontally from the corner
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 10
www.prosoco.com
Through-wall penetrationsJoint & Seam Filler
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
Fille
r
Between pipe and sheathing
PROSOCO R-GUARD®Joint & Seam Filler
Sheathing
Supporting structure
Pipe pentration
New Construction
Air and Water-Resistive/Waterproofing Barrier Systems
Step 2
To make a claim on PROSOCO’s R-GUARD warranties, you must meet all terms and conditions of the warranty, including use of the applicable R-GUARD Installation Guidelines. If a specific installation detail or technique is not covered, then the general principles outlined in the R-GUARD Installation Guidelines must have been followed. Contact PROSOCO with any questions regarding installation.
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 12
www.prosoco.com
Sheathing joint prepared with Joint Fabric, Spray Wrap,MVP or VB
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP or VB
Sheathing
Supporting structure
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 13
www.prosoco.com
Sheathing joint prepared with Joint & Seam Filler, Spray Wrap, MVP, VB or Cat-5
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5
Sheathing
Supporting structure
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
Applied over surface prepared with R-GUARD® Jont & Seam Filler
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 14
www.prosoco.com
Rough Opening prepared with Joint & Seam Filler, Spray Wrap, MVP or VB
PROSOCO R-GUARD®Spray Wrap, MVP or VB
Supporting structure
Fille
rPROSOCO R-GUARD®Joint & Seam Filler
Overlaps rough opening prepared with R-GUARD® GypPrime and R-GUARD® Joint & Seam Filler
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 15
www.prosoco.com
Rough Opening prepared with Joint & Seam Filler/FastFlash, Spray Wrap, MVP, VB or Cat-5
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5
Supporting structure
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
PROSOCO R-GUARD®FastFlash
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 16
www.prosoco.com
CMU Rough opening not previously treated.
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP or VB
Treat open cracks in rough opening with Joint& Seam Filler
Fille
r
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 17
www.prosoco.com
CMU Rough opening prepared with Joint & Seam Filler/FastFlash.
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
PROSOCO R-GUARD®FastFlash
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 18
www.prosoco.com
Through-Wall Penetrations Joint & Seam Filler and Spray Wrap, MVP, VB or Cat-5
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5
Supporting structure
Pipe pentration
Fille
r
PROSOCO R-GUARD®Joint & Seam Filler
New Construction
Air and Water-Resistive/Waterproofing Barrier Systems
Step 3
To make a claim on PROSOCO’s R-GUARD warranties, you must meet all terms and conditions of the warranty, including use of the applicable R-GUARD Installation Guidelines. If a specific installation detail or technique is not covered, then the general principles outlined in the R-GUARD Installation Guidelines must have been followed. Contact PROSOCO with any questions regarding installation.
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 20
www.prosoco.com
Parapet Terminationusing Spray Wrap, MVP, VB or Cat-5
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5
Roof MembranePROSOCO R-GUARD® Transition Membrane (coatable)
Supporting structure
Blocking and support for coping
Coping
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 21
www.prosoco.com
CMU Control Joint with Transition Membrane and Spray Wrap, MVP, VB or Cat-5
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD®Spray Wrap, MVP, VB or Cat-5Step A. Install transition membraneStep B. Overcoat transition membrane with Spray Wrap, MVP, VB or Cat-5
PROSOCO R-GUARD® Transition Membrane (coatable)
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 22
www.prosoco.com
Window Installation using AirDam
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® FastFlash
PROSOCO R-GUARD® AirDamInterior air and weather barrier sealant for windows and doors
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 23
www.prosoco.com
Metal flashing Treatment using Joint Fabric
PROSOCO R-GUARD® Spray Wrap, MVP or VB
Head Flashing
Pan Flashing
PROSOCO R-GUARD® Joint Fabric
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 24
www.prosoco.com
Metal flashing Treatment using Joint & Seam Filler and FastFlash
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
Fille
r
PROSOCO R-GUARD® FastFlash
Head Flashing
PROSOCO R-GUARD® Joint & Seam Filler
Supporting structure
PROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 25
www.prosoco.com
Brick Anchor Attachment
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
Brick Anchor
Installed Brick Anchor
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 26
www.prosoco.com
Termination at grade - Sheathing with Joint Fabric
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® Joint Fabric
Metal Flashing
PROSOCO R-GUARD® Transition Membrane (coatable)
Supporting structure
Sheathing
PROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 27
www.prosoco.com
Termination at grade - Sheathing with Joint & Seam Filler and FastFlash
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
Metal Flashing
Supporting structure
Sheathing
PROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
Fille
rPROSOCO R-GUARD® FastFlash
PROSOCO R-GUARD® Joint & Seam Filler
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 28
www.prosoco.com
StuccoPrime to receive stucco scratch coat
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® FastFlash
PROSOCO R-GUARD® StuccoPrime
PROSOCO R-GUARD® Cat-5
Stucco
Fille
r
PROSOCO R-GUARD® Joint & Seam Filler
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 29
www.prosoco.com
Through-Wall Flashing on CMU
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® FastFlash
Through-WallFlashing
CMU WallPROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
Fille
r
PROSOCO R-GUARD® Joint & Seam Filler
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 30
www.prosoco.com
Through-Wall Flashingon Sheathing
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® FastFlash
Through-Wall Flashing
PROSOCO R-GUARD® Spray Wrap, MVP, VB or Cat-5
Fille
r
PROSOCO R-GUARD® Joint & Seam Filler
Supporting structure
PROSOCO installation guidelines are illustrations of construction. They are intended for use by the design/construction professional to assist in developing project-specific details. They should be modified where necessary to accommodate individual project conditions. Refer to appropriate PROSOCO specification and Product Data Sheet. Updated February, 2011.
page 31
www.prosoco.com
Through-Wall Flashing on a Spandrel Construction
Cat-5FastFlashSpray Wrap
Joint & Seam EWS AirDam
GypPrimeStucco Prime Sheathing
PROSOCO R-GUARD® FastFlash
Through-wallFlashing Membrane
Fille
r
PROSOCO R-GUARD® Joint & Seam Filler
PROSOCO R-GUARD® Cat-5