Agilent ChemStation What’s New ?gRevision B.04.02 Adopting new technology
© Agilent Technologies 2010
Agilent ChemStation – Modern Instrument Control
Agilent RC.NET driver technology
• New Method & Run Control view
• XML method format
• Method migration
• LC/CE Method resolution• LC/CE Method resolution
• LC Macro compatibility
• GC News
Agilent ChemStation B.04.02© Agilent Technologies 2010
ChemStation B.04.02 – New Look for LC & CENew Look Classic LookNew Look Classic Look
Drivers RC.NET driver architecture ChemStation driver architecture
Instrument User Interface
Common UI (& drivers) inEZChrom and ChemStation
Proprietary UI – ChemStation only
SupportedModules
• 1100/1200 standard modules• 1290 modules, 7100 CE
• All 1100/1200 modules• No support for 1290 LC, 7100 CE
Diagnostics Diagnostics in Lab Advisor • 1100/1200 modules: Lab AdvisorDiagnostics Diagnostics in Lab Advisor • 1100/1200 modules: Lab Advisor• 1100 modules: Diagnostics View
OQ/PV • Limited OQ/PV View• Instrument qualification in ACE
• OQ/PV View available• Instrument qualification in ACE
Agilent ChemStation B.04.02
• Instrument qualification in ACE • Instrument qualification in ACE
© Agilent Technologies 2010
The New Look of the LC ChemStation in DetailStart/Stop/Pause buttons
Method information area
Instrument dashboard area for all modules
UI access to data analysis and ECM preferencespreferences
Information area or current samplep
Access to sample tray
Agilent ChemStation B.04.02© Agilent Technologies 2010
The New Look of the CE ChemStation in Detail
Instrument dashboard area for all modulesfor all modules
The new G7100A CE instrument is only supported with RC NETwith RC.NET drivers.
Agilent ChemStation B.04.02© Agilent Technologies 2010
The New Instrument Method Editor Single Method UI with one tab per modulemodule
Hide/show common timetable graph for all modules
Agilent ChemStation B.04.02© Agilent Technologies 2010
Changes & Benefits of RC.NETNew Interactive Method & Run Control View*
• Modern Navigation Elements and Design
– Tooltips context menus one-click access to dialogs etcTooltips, context menus, one click access to dialogs etc.
• Dashboard for Instrument Control replaces System Diagram
– Customizable
– Intuitive graphics, icons reveal additional information
– Display capabilities for multiple modules of the same type (e.g. pumps)
– Focus on most important information, visible even from a distance
Show/hide more detailed information per module– Show/hide more detailed information per module
Agilent ChemStation B.04.02
* Not yet in GC ChemStation
© Agilent Technologies 2010
Instrument Dashboard Capabilities – Demo
Customizable representation– Continuously adjustable in size– Show/hide elements
Freel arrange order of displa ed mod les
User Interface Demo Video
View video in explorer
– Freely arrange order of displayed modules – Choice to display more details per module– View modules of interest, minimize others
New intuitive instrument graphics
Dashboard Demo Video
New, intuitive instrument graphics – Easily identify the module – See current status– Access method settings
Most important information at a glance– See current values, method settings & limits – Clearly see status, even from a distance
Enhanced capabilities– Display multiple modules of the same type
(for example, pumps).
Agilent ChemStation B.04.02© Agilent Technologies 2010
Instrument Dashboard Capabilities – Demo
Customizable module names– Individual device names help to better distinguish identical
modules. (user’s choice)
Icons reveal more information– external contact board installed (see picture)– RFID tag present for
lView video in explorer
• columns• flow cell, or • lamp
– Tool tips reveal information stored in tags
Dashboard Icons
Demo Video
Instrument method editor– Single tabbed method user interface.
Method EditorDemo Video
View video in explorer
Embedded in new Method & Run Control View– Run control– Sample information area
Run Control Demo VideoVi id i l
Agilent ChemStation B.04.02
Sample information area
© Agilent Technologies 2010
View video in explorer
Changes & Benefits of RC.NETNew Interactive Method & Run Control View*New Interactive Method & Run Control View
• Not Ready status color
– Changed from red (now only used for error state) to yellowyellowChanged from red (now only used for error state) to yellowyellow
• Sequence and method change flags
– Sequence change flag moved to new sequence areaq g g q
– Method change flag moved to new method area
• LC Instrument Diagnostics
– No longer part of ChemStation
– Now entirely done in Lab Advisor
– Single, data system-independent application for diagnostics
Agilent ChemStation B.04.02
* Not yet in GC ChemStation
© Agilent Technologies 2010
Changes & Benefits of RC.NETGC ChemStation News
• 7693A ALS support on 6890 and 6850 GC systems
– New 7693A Automatic Liquid Sampler system can now be controlled withNew 7693A Automatic Liquid Sampler system can now be controlled with 6890 & 6850 Gas Chromatographs
Agilent ChemStation B.04.02© Agilent Technologies 2010
Changes & Benefits of RC.NETMethod handlingg
• New instrument method format– XML file structure
– Same format for ChemStation & EZChrom
– Checksum-protected
• Method migration– done automatically (no extra step)
– converted during method load (change flag is set)
– Silent migration during automation
Method resol tion (online ChemStation)• Method resolution (online ChemStation)– Consistency Check: Does method match current configuration?
Agilent ChemStation B.04.02© Agilent Technologies 2010
Method Resolution in Detail – What happens?New LC or CE RC.NET drivers
Method Resolution Type ConsequenceMethod Resolution Type Consequence
Consistent Method can be used –no modification required
Automatically Resolvable Method can be used –internal schema migration
Manual Resolution Recommended Method can be used –Optional parts of the method are removed
Manual Resolution Required
Method must be modified
Agilent ChemStation B.04.02© Agilent Technologies 2010
Method Resolution in Detail – ExamplesNew LC or CE RC.NET drivers
Method Resolution Type ExampleMethod Resolution Type Example
Consistent Method has new format and fits current configuration
Automatically Resolvable Old method is migrated (*.reg or *.mth *.XML format)
Manual Resolution Recommended Removed unused settings, e.g. external contacts board is not installed but part of method
Manual Resolution Required
Configuration mismatch, e.g. quaternary vs. binary pump
Agilent ChemStation B.04.02© Agilent Technologies 2010
Method Resolution in Detail – AutomationNew LC or CE RC.NET drivers
Method Resolution Type AutomationMethod Resolution Type Automation
Consistent Method is loaded and executed
Automatically Resolvable Method is loaded and executed
Manual Resolution Recommended Method is loaded, changed and executed; logbook entry describes change
Manual Resolution Required
Method is skipped; logbook entry describes reason
Agilent ChemStation B.04.02© Agilent Technologies 2010
Macro CompatibilityImpact of the RC.NET driver introduction p
• Data analysis or reporting macros– not affected, no changesnot affected, no changes
• Macros that interact with instruments– may require modification
• Register interface still exists– Same capabilities as before
– provides access to items, such as
• method parameters
• status informationstatus information
Agilent ChemStation B.04.02© Agilent Technologies 2010
Macro Compatibility DetailsMajor Differences compared to classic driversj p
• Register names are different
• Module status register content split into two:Module status register content split into two:
– status register
– configuration register
• Header item and table names inside register are mostly different
– Some header items have been split into two parts, for example StopTime no split intoStopTime now split into:
• StopTime_Time
• StopTime_Mode (either SET or NOLIMIT)p _ ( )
• New Pretreatment register hosts Injector program– no longer part of the method register
Agilent ChemStation B.04.02© Agilent Technologies 2010
LC/CE ChemStation B.04.02 Device Support
Device Type RC.NET UI Classic UI
1100 / 1200 standard & RR modules1100 / 1200 standard & RR modules (incl. SQ MSD & 35900E A/D)
1290 LC modules, 7100 CE
1290 with standard 1100/1200 modules
“Special” modules*Special modules
SQ MSD with 1290 or 7100
35900E A/D with 1290 or 7100
* RC.NET drivers will be available in the near future ! Special Modules are: Preparative system (G1361A, G1391A, G2260A), Micro / Nano system (G1382A, G1377A, G1387A,
Agilent ChemStation B.04.02
G2225A), Fraction Collector (G1364A), Dual Loop Autosampler (G2255A), ChipCube (G4220A), Cluster Drivers (G1316C TCC Cluster, G1160A/Pump Cluster)
© Agilent Technologies 2010
Agilent ChemStation – General Changes
General Changes
• Sequencing
• Instrument Qualification
• Diagnostics
• New version of OpenLAB• New version of OpenLAB Intelligence Reporter
Agilent ChemStation B.04.02© Agilent Technologies 2010
General Changes in ChemStation Sequencingq g
• Easy Sequence
– New user interface for simple sequence planning and queuingNew user interface for simple sequence planning and queuing
• New Sequence printout
– Format was changed to allow printing of very long names and text fieldsg p g y g
Agilent ChemStation B.04.02© Agilent Technologies 2010
Easy Sequence In more detail…
Easy Sequence consists of two phases
• Planning• Planning– Easy Sequence Template – Samples
– Easy Sequence Template – Calibration
• Execution– Easy Sequence – Submission
– Sequence Queue – Scheduled SequencesSequence Queue Scheduled Sequences
Agilent ChemStation B.04.02© Agilent Technologies 2010
Easy Sequence Template – SamplesPlanningg
Define sequence qcharacteristics –
• Method
• Namingg
• Data location
Agilent ChemStation B.04.02
Manager
© Agilent Technologies 2010
Easy Sequence Template – CalibrationPlanningg
Define sequence qcharacteristics –
• Calibration type
• Blanks
• Control samples
• Methods
Agilent ChemStation B.04.02
Manager
© Agilent Technologies 2010
Easy Sequence – SubmissionExecution
Create sequence qbased on template –
• Modify available parameters as neededneeded
• Review
• Submit to queue
Agilent ChemStation B.04.02
Operator
© Agilent Technologies 2010
Sequence Queue – Scheduled SequencesExecution
Monitor queue –q
•Active queue
– Pause / Resume
– Change order
•History queue
Agilent ChemStation B.04.02
Operator
© Agilent Technologies 2010
Easy Sequence What are the key benefits?y
It…
• … is easier to use
• … less error-prone due to pre-configured templates
t di ti t l l f l i d ti• … two distinct user levels for planning and execution
• … provides sequence queuing capabilities
Agilent ChemStation B.04.02© Agilent Technologies 2010
Instrument QualificationAgilent Compliance Engineg p g
• All Agilent instrument qualification is delivered with ACE
– Single application for deliverySingle application for delivery
– independent of data system
• ChemStation OQ/PV View
– Not used for Agilent delivery of qualification services
– Still fully available with classic drivers
– Will entirely disappear in near future
Agilent ChemStation B.04.02© Agilent Technologies 2010
Instrument Diagnostics Lab Advisor
• Agilent instrument diagnostics done with Lab Advisor
– Single application for diagnosticsSingle application for diagnostics
– independent of data system
• ChemStation Diagnostics Viewg
– Latest Agilent hardware not included
– Still available with classic drivers
– Will entirely disappear in near future
Agilent ChemStation B.04.02© Agilent Technologies 2010
General Changes in ChemStation Reportingp g
• NEW with OpenLAB Intelligence Reporter revision A.02.01*
– Easy to use Report Template Editor (RTE)Easy to use Report Template Editor (RTE)
– Reporting of chromatograms for one or multiple injections
– Reporting of calibration curves
– Reporting of spectra
– New “Quick Query” function
– OLIR Client without direct database connection
– New report controls for MS BI Studio
Agilent ChemStation B.04.02
*separate application, requires OpenLAB Enterprise Content Manager
© Agilent Technologies 2010
OpenLAB Intelligence Reporter Advanced ChemStation Reportingp g
ECM-based advanced report builder integrated into ChemStation for:g
– Sequence summary and cross-sequence reporting
– Custom calculations, trend-charting
– Decision-based results reporting
Agilent ChemStation B.04.02© Agilent Technologies 2010
OpenLAB Intelligence ReporterMore details…
• Extended reporting and knowledge generation via
– search-based report content selectionsearch based report content selection
– condense information by visualizing key results (e.g. in trend charts)
– decision-based result presentation(flag outliers, automatically sort results by pass/fail criteria, etc.)
– custom calculation(e.g. summary calculations, statistics, complex reports like Dissolution Tests)
• Report on data from Agilent data systems stored in OpenLAB ECM
• Capabilities to report on non-chromatographic data(ECM administration, ECM usage, ….)
Agilent ChemStation B.04.02© Agilent Technologies 2010
What’s New in ChemStation Revision B.04.02Summaryy
• New Method & Run Control View – Modern design with intuitive navigation elements is complemented by the new dashboard for easy g y yinstrument control.
• Full compatibility of existing methods is facilitated by automatic method i ti d th th d l timigration and the new method resolution.
• Easy sequence is a new user interface for simple sequence planning, submission and queuingsubmission and queuing
• Agilent Compliance Engine for instrument qualification of the entire lab
• Lab Advisor – one application for instrument diagnostics independent of the data system
• Advanced Reporting capabilities with OpenLAB Intelligence Reporter i i B 02 01
Agilent ChemStation B.04.02
revision B.02.01
© Agilent Technologies 2010