AFMS_Caldon07

download AFMS_Caldon07

of 42

description

caldon

Transcript of AFMS_Caldon07

  • Acadiana Flow Measurement SchoolLafayette, LAApril 17- 18, 2007

    RAISING PERFORMANCE. TOGETHERTM

    Liquid UltrasonicFlow Meters

    MEASUREMENT SYSTEMS

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Liquid Ultrasonic Meter with Integral TransmitterLiquid Ultrasonic Meter with Integral Transmitter

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    TransTrans--Alaska PipelineAlaska PipelineFirst Multi-path Ultrasonic Flow Meters for Liquid Petroleum Measurement

    Application: Line Balance

    Pipeline Length: ~ 800 miles

    Number of Meters: 23

    Size: 48 inch

    Rate: ~ 100,000 BPH

    Date Installed: 1976

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Creating Ultrasonic Sound Creating Ultrasonic Sound Piezoelectric Phenomenon

    Crystal Rings to Produce Ultrasound 0.5 to 2 MHz

    -1

    -0.8

    -0.6

    -0.4

    -0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    3.20E-05 3.30E-05 3.40E-05 3.50E-05 3.60E-05 3.70E-05 3.80E-05 3.90E-05 4.00E-05

    Voltage+

    -

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Sound Wave Converted to Voltage

    -1

    -0.8

    -0.6

    -0.4

    -0.2

    0

    0.2

    0.4

    0.6

    0.8

    1

    3.20E-05 3.30E-05 3.40E-05 3.50E-05 3.60E-05 3.70E-05 3.80E-05 3.90E-05 4.00E-05Voltage

    Sound

    +

    -

    Sensing Ultrasonic SoundSensing Ultrasonic SoundPiezoelectric Phenomenon

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    TransitTransit Time FlowmetersTime Flowmeters

    Tup = L/(C-V cos)Tdown = L/(C+V cos)

    Where: L = Path LengthC = Speed of Sound in the fluid = Angle of sound path to the pipe axisV = Average velocity along the pipe axis

    The solution for fluid velocity is independent of the speed of sound (C)

    2cos )T(TLV

    du =

    Tup

    Tdown

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    PP11PP22PP33PP44

    Differential Transit TimeDifferential Transit Time

    Spool

    Signal Processing unit

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    WettedWetted Transducers Transducers No RefractionNo Refraction

    Caldon LEFM 240C

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    AccousticAccoustic Transducer Housings and RTDTransducer Housings and RTDCaldon LEFM 240C

    Transducer Housings

    RTD Temperature Probe

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    AccousticAccoustic Transducer AssemblyTransducer Assembly

    Spacer Spring

    Transducer HousingCompression Nut

    Weld

    Transducer

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Chordal Acoustic Paths and Flow ProfileChordal Acoustic Paths and Flow Profile

    ( ) CosTT TPathLengthPnV downup =

    2)(

    Velocity of Each Path

    AVkQ ii

    bi = =

    4

    1

    Integration into a Flow Measurement60-70 times per second

    P1

    P2

    P3

    P4

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Frequency Generator

    Pulse FormationPulse Formation

    AVkQ ii

    bi = =

    4

    1

    1/60 Sec

    1/60 Sec

    1/60 Sec

    1/60 Sec

    Continuous Pulse Output

    1/60 Sec

    1/60 Sec

    1/60 Sec

    1/60 Sec

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Transmitter(Signal Processing Unit)

    Power: 24 Vdc, 120 Vac, 240 Vac

    3 Pulse Channels: 0 5 V

    Serial: ModBus RTU Up to 4 Analogs

    Out:Flow Rate

    DensityTemperature

    Viscosity

    Flow

    Up to 3 Analogs In:Temperature

    PressureDensity

    Transmitter (Signal Processing Unit) Transmitter (Signal Processing Unit) Inputs and Output

    Interconnect Cables

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Meter PricesMeter Prices

    E

    x

    p

    e

    n

    s

    e

    (

    $

    )

    Increasing uncertainty

    Cost of metering system

    Financial exposure

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Meter Measurement UncertaintyMeter Measurement Uncertainty

    Application Typical Uncertainty

    Line Balance or Check Metering +/- 0.3 to 0.5%

    Custody Transfer +/- 0.15 to 0.25%

    Master Meter +/- 0.1 to 0.12%

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    TwoTwo--Path MeterPath MeterLine Balance and Check Metering

    Major CharacteristicsStabilityReproducibilityReliabilityBidirectional Flow Economy

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    FourFour--Path MeterPath MeterCustody Transfer Measurement

    Major CharacteristicsPrecision Accuracy LinearityStabilityBidirectional FlowProvability

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    EightEight--Path MeterPath MeterPremium Custody Transfer and Master Meter Measurement

    Major CharacteristicsPremium Accuracy Immune to Installation Effects Total RedundancyBidirectional FlowMaster Meter

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Meter Installation and Flow Conditioning Meter Installation and Flow Conditioning

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Horizontal Meter Orientation Horizontal Meter Orientation

    Avoids: Gas Interference at the Top of the Pipe Particles/Water at the bottom of the Pipe

    Horizontal Acoustic Paths

    Gas

    Water/particles

    ChordalPaths

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Proving Ultrasonic Flow Meters Proving Ultrasonic Flow Meters

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Theory of Proving Theory of Proving Flow

    Known Volume

    Meter Displacer Detectors

    Pipe/Displacer/Detectors

    Known volume (undisputed)

    1st Mile long prover in USA 1958

    Modern provers

    Bidirectional Unidirectional Small Volume

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Theory of Proving

    Comparison of the Meters Registration and to a Known Volume (Standard) to Determine a Meter Factor

    The Comparison is Made Several Times and the Repeatability Measured

    The Conditions at the Time are Recorded

    The Process is Called Proving

    )()(

    metervolumeindicatedprovervolumeactualFactorMeter =

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Repeatability of Ultrasonic Flow MetersRepeatability of Ultrasonic Flow Meters

    Vortices formed by viscous shear Against the pipe wall

    Standard Deviation of Transit Time Measurement Between 1% and 2%

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    API Chapter 4.8, Appendix A

    Proving Runs

    Repeatability Limit

    Meter Factor Uncertainty

    3 0.02 2.7/10,000

    4 0.03 2.7/10,000

    5 0.05 2.7/10,000

    6 0.06 2.7/10,000

    7 0.08 2.7/10,000

    8 0.09 2.7/10,000

    9 0.10 2.7/10,000

    10 0.12 2.7/10,000

    11 0.13 2.7/10,000

    12 0.14 2.7/10,000

    13 0.15 2.7/10,000

    14 0.16 2.7/10,000

    15 0.17 2.7/10,000

    16 0.18 2.7/10,000

    17 0.19 2.7/10,000

    18 0.20 2.7/10,000

    19 0.21 2.7/10,000

    20 0.22 2.7/10,000

    Repeatability of Proving RunsRepeatability of Proving Runs

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Prover Size and Proving RepeatabilityProver Size and Proving Repeatability

    Prover Volume vs Meter Size

    5 Runs 0.05% 8 Runs 0.09% 10 Runs 0.12% 15 Runs 0.17%

    Prover Size (bbl)4 33 15 10 6

    6 73 34 22 14

    8 130 60 40 25

    10 203 94 62 39

    12 293 135 89 56

    14 399 184 121 77

    16 521 241 158 100

    Meter Size (in.)

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Prover Size and Repeatability Prover Size and Repeatability Small Volume ProversSmall Volume Provers

    Proving Runs and Passes per Run5 Runs, 1 Pass per Run

    5 Runs, 5 Passes per Run

    5 Runs, 10 Passes per Run

    10 Runs, 1 Pass per Run

    10 Runs, 5 Passes per Run

    10 Runs, 10 Passes per Run

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Small Volume Prover Small Volume Prover Proving ReportProving Report

    3 Passes per Run,

    5 Runs Repeat within

    0.05%

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Manufactured Pulses Delay and Dampening

    Fundamental Pulse Delay or Sampling Period (PD)Dampening Filter Time Constant (DT)Proving Run Time (PT)Flow Rate Change (%) during the Prove Run (RC)

    Time

    PDDT DT DT

    PT

    F

    l

    o

    w

    R

    a

    t

    e

    RC

    Erroneous Indication of

    Volume due to PD and DT

    PTDTPDRCError )((%) +

    Example:

    .5%(0.020+0.100)/0.500 = 1.2% Error

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Meter CharacterizationMeter Characterization

    Improves meter accuracy by compensating for non-linearity of raw Meter Factor for varying Reynolds Number (Re)

    Meter is calibrated in a laboratory on liquids and flow rates that most closely match the application Re

    Because the meter directly measures the flow rate and viscosity, it knows the current Re and make the appropriate correction

    QDRe =

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    OIML Specification OIML Specification R117 LinearityR117 Linearity

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    OIML Specification OIML Specification R117 Linearity R117 Linearity

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    API Chapter 5.8API Chapter 5.8

    Recommend Practices for the Custody Transfer Measurement of

    Liquid Petroleum

    Recommend Practices for the Custody Transfer Measurement of

    Liquid Petroleum

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Meter Calibration versus In-situ Proving

    API MPMS Chapter 5.8

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    White Rose FPSO Meters at SPSE, FranceWhite Rose FPSO Meters at SPSE, France

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Husky Oil Crude Oil Metering System - White Rose FPSO

    Measurement System Measurement System -- Master MeterMaster Meter

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    International Organization for International Organization for Legal Metrology Legal Metrology

    OIML R 117A Series of Tests to Insure Operation and Performance Suitable for Custody Transfer Measurement

    OIML R 117A Series of Tests to Insure Operation and Performance Suitable for Custody Transfer Measurement

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    OIML Performance Specification OIML Performance Specification R117R117

    Additional Requirements:

    Sealing and Password Protection

    Dry Heat

    Power Voltage Variations

    Short Time Power Reductions

    Electrostatic Bursts

    Electromagnetic Susceptibility

    Tampering

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Certification by a third Party (NMi) that the Meter Meets the Requirements

    Certification by a third Party (NMi) that the Meter Meets the Requirements

    LEFM 240C

    LEFM 220C

    OIML ROIML R--117 Certification117 Certification

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    Advantages of Ultrasonic Flow MetersAdvantages of Ultrasonic Flow Meters Simplicity of Measurement System

    Large Size Meters Smaller Systems Fewer Components

    Reduced Cost of Measurement & Ownership No Wearing Parts Low P Less Proving

    Multi-property Measurement Density Viscosity Temperature VOS Diagnostics, etc.

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM

    In a NutshellValue of Ultrasonic Meters

    Simplest Measurement Solution

    Lowest Cost CAPEX & OPEX

    Not Just a Flow Meter

  • MEASUREMENT SYSTEMS

    RAISING PERFORMANCE. TOGETHERTM