AeroMACS SARPS Validation Report from SESAR Project 9.16
Sixth Meeting of the Surface Datalink Working GroupSendai, November 13th-14th, 2014
Domenico CardamoneAvionics LoB
CTO/Capability Department
2© 2014 Selex ES S.p.A. – All rights reserved
SESAR WP 9.16 Test Strategy
Thales BS-MS Local integration
In Thales lab
Selex BS-MS Local integration
In Selex lab
Thales BS withSelex MS
Interoperability
Thales BS
Thales MS
Selex BS
Selex MS
Selex MSStatic Tests from Airbus Laboratory
(BS at the Airport)
Thales BS and MSTests with carsOn Toulouse
Airport
Thales BS
Thales MS
Selex BS and MSTests with cars
On ToulouseAirport
Selex BS and MSTests with A/COn Toulouse
Airport
Project 9.16VerificationActivities
Project 15.2.7VerificationActivities
Selex BS withThales MS
Interoperability
STEP 1
STEP 2
STEP 3
STEP 4
3© 2014 Selex ES S.p.A. – All rights reserved
AeroMACS SARPS Validation Report from SESAR WP 9.16Contents
This document presents a subset of the Validation and Verification results from the project SESAR 9.16. These results contribute to the validation of the AeroMACS SARPS.
• SESAR 9.16 Project Overview• Airbus & Selex ES & Test Benchs Description• Selex ES AeroMACS MS/BS prototype description• Summary of the Lab Test performed by Selex ES• Summary of the Test performed by Airbus
• Validation Items and Results Summary• Lists of AeroMACS SARPs Requirements and validation results
• Selex ES Tests Details Report• Lab Test Reports
• Airbus Tests Details Report• Lab Tests Report• Car Tests Report• A/C Tests Report
4© 2014 Selex ES S.p.A. – All rights reserved
AeroMACS SARPS Validation Report from SESAR WP 9.16 Main Results• Selex ES Lab Test Report are OK (STEP 1)• Selex ES has to test data transfer with Security and Handover with data transfer• Airbus Test Lab Test Report are generally OK, remarks about a high PLR not
confirmed during the static test field • Airbus Test Lab Test Report has no report for data transfer with security (STEP2)• Airbus static field test about RTT/Jitter/UDP-TCP Throughput are OK• Airbus Car Test were limited by the limited signal coverage over the Airport, so
mobility tests (doppler, handover and throughput) were not possible all over the airport surface (STEP3)
• Airbus A/C tests about AeroMACS integration on board are OK (STEP 4)• Airbus A/C mobility test yet to be done.