Aero Derivative GT
Transcript of Aero Derivative GT
-
7/31/2019 Aero Derivative GT
1/3
Aero derivative GT
LM2500 LM5000 LM6000
Max Output (kW) 33400 34451 43850
Comp. stage (LPC,HPC) 17 19 (14,5) 19 (14,5)
Turb. Stage (HPT,LPT) 6 3 (2,1,3 power turbine) 7 (2,5)Spool 1 2 2
Pressure ratio 23 : 1 28.5 : 1
Turbine speed (rpm) 3600 3600 3600
Exhaust temp (F) 786.48 708.15 728.15
Low Heat Value (Btu/kWs-h) 8850 9080 8515
th % - simple cycle 39 38 42
Frequency (Hz) 50/60 50/60
LM2500
LM6000
GE
-
7/31/2019 Aero Derivative GT
2/3
LM5000
-
7/31/2019 Aero Derivative GT
3/3
R-R P&W
Trent 60 FT8
51000
15 (7,8)
3 (1,2,4 power turbine)3 2
35 : 1
3600 3600
713.15
8586 (kJ/kWe-hr)
42