AECMSA Electrical Cable Price Variation Factors

64
SANS 97 SANS 1507 SANS 1339 BS6346 SATS CSE 49E & G 2007 JOHANNESBURG FOR EACH R1,00, RISE OR FALL, PER METRIC TON IN THE PRICES OF COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE. ISSUED BY THE ASSOCIATION OF ELECTRIC CABLE MANUFACTURERS OF SOUTH AFRICA COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE PRICE VARIATION FACTORS FOR ELECTRIC CABLES CONFORMING TO SPECIFICATIONS:- THE VARIATIONS IN THIS BOOKLET ARE PER 100 METRES OF CABLE

Transcript of AECMSA Electrical Cable Price Variation Factors

Page 1: AECMSA Electrical Cable Price Variation Factors

SANS 97

SANS 1507

SANS 1339

BS6346

SATS CSE 49E & G

2007 JOHANNESBURG

FOR EACH R1,00, RISE OR FALL, PER METRIC TON IN

THE PRICES OF COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE.

ISSUED BY

THE ASSOCIATION OF ELECTRIC CABLE MANUFACTURERS OF SOUTH AFRICA

COPPER, ALUMINIUM, LEAD, STEEL, PVC AND XLPE PRICE VARIATION FACTORS

FOR ELECTRIC CABLES

CONFORMING TO SPECIFICATIONS:-

THE VARIATIONS IN THIS BOOKLET ARE PER 100 METRES OF CABLE

Page 2: AECMSA Electrical Cable Price Variation Factors

Page 1 1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 2 1000V Low Tension General Purpose Cables to SANS 97 AFAA

Page 3 3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 4 3,3kV General Purpose Belted Cables to SANS 97 AFAA

Page 5 6,6kV General Purpose Belted Fully impregnated Cables to SANS 97 Tables 9 & 15

Page 6 6,6kV General Purpose Belted Fully impregnated cables to SANS 97 Table 16

Page 7 6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 8 6,6kV General Purpose Belted Drained Cables to SANS 97 AFAA

Page 9 11kV General Purpose Fully Impregnated Belted Cables to SANS 97 Tables 17 & 18

Page 10 11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 Tables 10 & 19.

Page 11 11kV Screened Type Fully Impregnated General Purpose Cables to SANS 97 AFAA

Page 12 11kV Drained General Purpose Belted Cables for Normal Service Conditions &

11kV Fully Impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 13 11kV Screened Type Drained General Purpose Cable for Normal Service Conditions &

11kV Fully impregnated Cables with Augmented Dielectric to SANS 97 AFAA

Page 14 12,7/22kV General Purpose Impregnated Screened Cables to SANS 97 Tables 11 & 20

Page 15 1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 16 1000V Low Tension Heavy Duty Cables to SANS 97 AFAA

Page 17 3,3kV Heavy Duty (Belted) Cables to SANS 97 AFAA

Page 18 3,3kV Heavy Duty (Belted) Cables to SANS 97 Table 22.

Page 19 6,6kV Heavy Duty (Belted) Cables to SANS 97 Tables 13 & 23

Page 20 6,6kV Heavy Duty (Belted) Cables to SANS 97 Table 24

Page 21 11kV Heavy Duty (Belted) Cables to SANS 97 Tables 25 & 26

Page 22 11kV Heavy Duty Screened Cables to SANS 97 Tables 14 & 27

Page 23 11kV Heavy Duty Screened Cables to SANS 97 AFAA

Page 24 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 25 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 26 600/1000V PVC PVC SWA PVC Cables to SANS 1507

Page 27 600/1000V PVC PVC ECC/SWA PVC Cables to SANS 1507

Page 28 1,9/3,3kV 3 Core PVC PVC SWA PVC Cables to SANS 1507

Page 29 600/1000V Stranded AL PVC PVC SWA PVC Cables to SANS 1507

Page 30 600/1000V Solid AL PVC PVC SWA PVC Cables to SANS 1507

Page 31 600/1000V Solid AL PVC PVC SWA/ECC PVC Cables to SANS 1507

Page 32 600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC Cables to BS 6346

Page 33 600/1000V PVC PVCT ASA PVC Cables to BS 6346

Page 34 600/1000V 3 Core PVC PVC Cables with Split-Concentric Neutral &

Earth Conductors to SANS 1507

Page 35 3,8/6,6kV single core type A Cable to SANS 1339

Page 36 6,35/11kV single core type A cable to SANS 1339

Page 37 8,7/15kV single core type A cable to SANS 1339 AFAA

Page 38 12,7/22kV single core type A cable to SANS 1339

Page 39 19/33kV single core type A cable to SANS 1339

INDEX

Printed 2007/06/13 Index Page 1

Page 3: AECMSA Electrical Cable Price Variation Factors

Page 40 3,8/6,6kV single core type A2 cable to SANS 1339 AFAA

Page 41 6,35/11kV single core type A2 cable to SANS 1339 AFAA

Page 42 8,7/15kV single core type A2 cable to SANS 1339 AFAA

Page 43 12,7/22kV single core type A2 cable to SANS 1339 AFAA

Page 44 19/33kV single core type A2 cable to SANS 1339 AFAA

Page 45 3,8/6,6kV single core type B cables to SANS 1339

Page 46 6,35/11kV single core type B cable to SANS 1339

Page 47 8,7/15kV single core type B cable to SANS 1339 AFAA

Page 48 12,7/22kV single core type B cable to SANS 1339

Page 49 19/33kV single core type B cable to SANS 1339

Page 50 3,8/6,6kV three core type A cable to SANS 1339

Page 51 6,35/11kV three core type A cable to SANS 1339

Page 52 8,7/15kV three core type A cable to SANS 1339 AFAA

Page 53 12,7/22kV three core type A cable to SANS 1339

Page 54 19/33kV three core type A cable to SANS 1339

Page 55 3,8/6,6kV three-core type B cable to SANS 1339

Page 56 6,35/11kV three-core type B cable to SANS 1339

Page 57 8,7/15kV three-core type B cable to SANS 1339 AFAA

Page 58 12,7/22kV three-core type B cable to SANS 1339

Page 59 19/33kV three-core type B cable to SANS 1339

Page 60 Standard Signaling Cables (outdoor) to SATS Specification No.CSE 49E

Page 61 Standard Signaling Cables (indoor) to SATS Specification No.CSE 49G

INDEX

Printed 2007/06/13 INDEX 2

Page 4: AECMSA Electrical Cable Price Variation Factors

PAGE 1

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING AREA

mm2 SERVING OVER & mm2

OVER ARMOUR SERVING

ARMOUR COMBINED

6 - - - - 0.011* - 0.071 0.057 0.062 0.025 0.037 6

10 - - - - 0.019 - 0.071 0.056 0.060 0.025 0.036 10

16 - - - - 0.031 - 0.080 0.060 0.063 0.026 0.039 16

25 - - - - 0.048 0.014 0.088 0.067 0.070 0.032 0.043 25

35 - - - - 0.067 0.021 0.098 0.073 0.075 0.034 0.048 35

50 - - - - 0.095 0.030 0.109 0.079 0.101 0.038 0.057 50

70 - - - - 0.134 0.041 0.131 0.086 0.113 0.043 0.064 70

95 - - - - 0.181 0.055 0.167 0.095 0.120 0.050 0.092 95

120 - - - - 0.250 0.071 0.193 0.101 0.133 0.054 0.087 120

150 0.142 0.044 0.123 0.021 0.287 0.080 0.209 0.137 0.180 0.063 0.103 150

185 0.175 0.053 0.143 0.023 0.354 0.109 0.235 0.147 0.193 0.067 0.112 185

240 0.228 0.070 0.171 0.028 0.459 0.141 0.297 0.164 0.215 0.079 0.130 240

300 0.204 0.087 0.203 0.035 0.574 0.176 0.361 0.191 0.237 0.092 0.151 300

400 0.379 0.117 0.258 0.043 - 0.235 0.455 0.202 0.337 0.103 0.168 400

500 0.474 0.146 0.288 0.047 - 0.294 0.510 0.220 0.366 0.112 0.192 500

630 0.598 0.183 0.351 0.057 - - - - - - - 630

STEEL PVC

* Circular conductors

PAGE 1

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA

SINGLE CORE 2 CORE

Printed 2007/06/13

Page 5: AECMSA Electrical Cable Price Variation Factors

PAGE 2

RATED COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREA

mm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVING

COMBINED COMBINED

6 0.017* - 0.076 0.059 0.066 0.026 0.039 0.023* - 0.084 0.064 0.069 0.027 0.042 6

10 0.029* - 0.087 0.066 0.072 0.032 0.043 0.030* - 0.096 0.070 0.077 0.033 0.047 10

16 0.046* - 0.100 0.070 0.098 0.035 0.051 0.062* - 0.119 0.077 0.106 0.038 0.058 16

25 0.072 0.022 0.100 0.072 0.084 0.035 0.051 0.095 0.030 0.122 0.082 0.109 0.041 0.059 25

35 0.100 0.031 0.119 0.078 0.107 0.038 0.058 0.134 0.041 0.145 0.087 0.119 0.046 0.072 35

50 0.144 0.044 0.143 0.086 0.117 0.043 0.065 0.191 0.058 0.172 0.096 0.130 0.053 0.084 50

70 0.201 0.062 0.170 0.094 0.128 0.051 0.083 0.268 0.082 0.209 0.133 0.183 0.063 0.103 70

95 0.273 0.084 0.203 0.129 0.180 0.060 0.101 0.364 0.112 0.257 0.149 0.202 0.071 0.119 95

120 0.344 0.106 0.235 0.140 0.194 0.066 0.110 0.459 0.140 0.297 0.160 0.215 0.079 0.130 120

150 0.431 0.132 0.265 0.152 0.200 0.076 0.122 0.574 0.176 0.360 0.174 0.238 0.091 0.049 150

185 0.531 0.163 0.309 0.163 0.223 0.083 0.140 0.708 0.217 0.437 0.189 0.327 0.099 0.161 185

240 0.689 0.211 0.381 0.192 0.295 0.097 0.156 0.919 0.282 0.529 0.212 0.370 0.111 0.189 240

300 0.861 0.264 0.450 0.201 0.351 0.105 0.179 1.148 0.353 0.630 0.234 0.440 0.122 0.209 300

400 - 0.353 0.581 0.233 0.390 0.110 0.201 - 0.470 0.752 0.269 0.513 0.134 0.230 400

500 - 0.441 0.679 0.253 0.481 0.127 0.217 - 0.588 0.907 0.292 0.627 0.145 0.249 500

630 - - - - - - - - - - - - - - 630* Circular conductors

PAGE 2

STEEL PVC STEEL PVC

1000V LOW TENSION GENERAL PURPOSE CABLES TO SANS 97 AFAA

3 CORE 4 CORE

Printed 2007/06/13

Page 6: AECMSA Electrical Cable Price Variation Factors

PAGE 3

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.129 0.070 0.111 0.041 0.061 16

25 - - - - 0.072 0.022 0.130 0.080 0.111 0.041 0.061 25

35 - - - - 0.100 0.031 0.145 0.086 0.118 0.044 0.072 35

50 - - - - 0.144 0.044 0.171 0.094 0.128 0.051 0.082 50

70 - - - - 0.201 0.062 0.202 0.129 0.165 0.059 0.100 70

95 - - - - 0.273 0.084 0.235 0.141 0.194 0.066 0.110 95

120 - - - - 0.344 0.106 0.268 0.152 0.207 0.076 0.121 120

150 0.142 0.044 0.141 0.023 0.431 0.132 0.298 0.163 0.222 0.080 0.137 150

185 0.175 0.053 0.150 0.027 0.531 0.163 0.364 0.174 0.239 0.091 0.149 185

240 0.228 0.070 0.179 0.029 0.689 0.211 0.436 0.192 0.334 0.100 0.163 240

300 0.284 0.087 0.213 0.037 0.861 0.264 0.519 0.211 0.368 0.111 0.189 300

400 0.379 0.117 0.257 0.044 - 0.353 0.639 0.238 0.396 0.120 0.205 400

500 0.474 0.146 0.299 0.047 - 0.441 0.740 0.258 0.489 0.130 0.222 500

630 0.598 0.183 0.360 0.058 - - - - - - - 630

STEEL PVC

* Circular conductors

PAGE 3

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA

1,9/3,3kV

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 7: AECMSA Electrical Cable Price Variation Factors

PAGE 4

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.132 0.081 0.115 0.043 0.064 16

25 - - - - 0.072 0.022 0.131 0.083 0.116 0.043 0.064 25

35 - - - - 0.100 0.031 0.151 0.090 0.123 0.045 0.077 35

50 - - - - 0.144 0.044 0.180 0.097 0.133 0.053 0.085 50

70 - - - - 0.201 0.062 0.211 0.134 0.183 0.063 0.103 70

95 - - - - 0.273 0.084 0.246 0.146 0.200 0.067 0.113 95

120 - - - - 0.344 0.106 0.278 0.156 0.214 0.077 0.124 120

150 0.142 0.044 0.149 0.026 0.431 0.132 0.319 0.167 0.239 0.088 0.143 150

185 0.175 0.053 0.170 0.028 0.531 0.163 0.371 0.179 0.245 0.093 0.152 185

240 0.228 0.070 0.197 0.035 0.689 0.211 0.457 0.196 0.342 0.102 0.167 240

300 0.284 0.087 0.225 0.038 0.861 0.264 0.539 0.216 0.375 0.112 0.192 300

400 0.379 0.117 0.278 0.045 - 0.353 0.644 0.242 0.459 0.123 0.209 400

500 0.474 0.146 0.303 0.049 - 0.441 0.750 0.262 0.491 0.131 0.225 500

630 0.598 0.183 0.360 0.059 - - - - - - - 630

STEEL PVC

* Circular conductors

PAGE 4

3,3kV GENERAL PURPOSE (BELTED) CABLES TO SANS 97 AFAA

3,3/3,3kV

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 8: AECMSA Electrical Cable Price Variation Factors

PAGE 5

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.066* - 0.151 0.086 0.118 0.045 0.077 16

25 - - - - 0.072 0.022 0.150 0.088 0.120 0.044 0.076 25

35 - - - - 0.100 0.031 0.172 0.094 0.128 0.051 0.083 35

50 - - - - 0.144 0.044 0.194 0.101 0.137 0.054 0.085 50

70 - - - - 0.201 0.062 0.233 0.139 0.192 0.065 0.107 70

95 - - - - 0.273 0.084 0.261 0.152 0.208 0.076 0.121 95

120 - - - - 0.344 0.106 0.310 0.162 0.222 0.080 0.131 120

150 0.142 0.044 0.151 0.027 0.431 0.132 0.361 0.173 0.237 0.091 0.148 150

185 0.175 0.053 0.172 0.029 0.531 0.163 0.382 0.185 0.296 0.097 0.158 185

240 0.228 0.070 0.201 0.035 0.689 0.211 0.464 0.202 0.350 0.105 0.177 240

300 0.284 0.087 0.234 0.039 0.861 0.264 0.554 0.221 0.384 0.116 0.196 300

400 0.379 0.117 0.267 0.046 - 0.353 0.663 0.248 0.472 0.125 0.213 400

500 0.474 0.146 0.310 0.054 - 0.441 0.781 0.269 0.508 0.134 0.227 500

630 0.598 0.183 0.371 0.059 - - - - - - - 630

STEEL PVC

* Circular conductors

PAGE 5

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLES 9 & 15

3,8/6,6kV EARTHED

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 9: AECMSA Electrical Cable Price Variation Factors

PAGE 6

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.172 0.094 0.125 0.051 0.083 16

25 - - - - 0.072 0.022 0.172 0.095 0.129 0.051 0.082 25

35 - - - - 0.100 0.031 0.182 0.099 0.135 0.054 0.086 35

50 - - - - 0.144 0.044 0.213 0.138 0.186 0.063 0.103 50

70 - - - - 0.201 0.062 0.254 0.147 0.201 0.070 0.118 70

95 - - - - 0.273 0.084 0.293 0.158 0.217 0.078 0.126 95

120 - - - - 0.344 0.106 0.317 0.168 0.230 0.088 0.144 120

150 0.142 0.044 0.171 0.028 0.431 0.132 0.373 0.179 0.245 0.093 0.153 150

185 0.175 0.053 0.194 0.030 0.531 0.163 0.445 0.192 0.334 0.100 0.163 185

240 0.228 0.070 0.224 0.037 0.689 0.211 0.488 0.209 0.375 0.109 0.186 240

300 0.284 0.087 0.252 0.044 0.861 0.264 0.570 0.227 0.395 0.118 0.202 300

400 0.379 0.117 0.299 0.048 - 0.353 0.684 0.253 0.479 0.128 0.217 400

500 0.474 0.146 0.348 0.057 - 0.441 0.790 0.275 0.519 0.137 0.234 500

630 0.598 0.183 0.380 0.066 - - - - - - - 630

STEEL PVC

* Circular conductors

PAGE 6

6,6kV GENERAL PURPOSE (BELTED) FULLY IMPREGNATED CABLES TO SANS 97 TABLE 16

6,6/6,6kV UNEARTHED

SINGLE CORE 3 CORE TABLE 16

Printed 2007/06/13

Page 10: AECMSA Electrical Cable Price Variation Factors

PAGE 7

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* 0.177 0.093 0.127 0.053 0.084 16

25 - - - - 0.072 0.022 0.172 0.095 0.131 0.051 0.083 25

35 - - - - 0.100 0.031 0.201 0.120 0.164 0.056 0.097 35

50 - - - - 0.144 0.044 0.225 0.138 0.194 0.064 0.106 50

70 - - - - 0.201 0.062 0.267 0.152 0.204 0.071 0.119 70

95 - - - - 0.273 0.084 0.297 0.163 0.220 0.079 0.130 95

120 - - - - 0.344 0.106 0.361 0.174 0.237 0.090 0.147 120

150 0.142 0.044 0.168 0.028 0.431 0.132 0.383 0.183 0.295 0.096 0.155 150

185 0.175 0.053 0.181 0.030 0.531 0.163 0.445 0.197 0.339 0.101 0.165 185

240 0.228 0.070 0.209 0.036 0.689 0.211 0.532 0.215 0.371 0.111 0.189 240

300 0.284 0.087 0.257 0.043 0.861 0.264 0.613 0.234 0.399 0.120 0.205 300

400 0.379 0.117 0.287 0.047 - 0.353 0.738 0.262 0.487 0.130 0.222 400

500 0.474 0.146 0.353 0.056 - 0.441 0.852 0.282 0.597 0.139 0.237 500

630 0.598 0.183 0.382 0.065 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 7

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA

3,8/6,6kV EARTHED

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 11: AECMSA Electrical Cable Price Variation Factors

PAGE 8

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.202 0.130 0.181 0.086 0.101 16

25 - - - - 0.072 0.022 0.204 0.130 0.166 0.085 0.100 25

35 - - - - 0.100 0.031 0.224 0.137 0.189 0.091 0.105 35

50 - - - - 0.144 0.044 0.256 0.148 0.196 0.100 0.118 50

70 - - - - 0.201 0.062 0.297 0.159 0.217 0.110 0.126 70

95 - - - - 0.273 0.084 0.316 0.170 0.233 0.126 0.145 95

120 - - - - 0.344 0.106 0.377 0.181 0.293 0.133 0.154 120

150 0.142 0.044 0.194 0.030 0.431 0.132 0.445 0.193 0.334 0.141 0.164 150

185 0.175 0.053 0.203 0.036 0.531 0.532 0.477 0.203 0.354 0.151 0.179 185

240 0.228 0.070 0.234 0.039 0.689 0.211 0.560 0.221 0.384 0.165 0.195 240

300 0.284 0.087 0.278 0.046 0.861 0.264 0.642 0.240 0.474 0.179 0.212 300

400 0.379 0.117 0.306 0.055 - 0.353 0.772 0.267 0.505 0.191 0.228 400

500 0.474 0.146 0.370 0.059 - 0.441 0.886 0.287 0.612 0.205 0.245 500

630 0.598 0.183 0.445 0.069 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 8

6,6kV GENERAL PURPOSE (BELTED) DRAINED CABLES TO SANS 97 AFAA.

6,6/6,6kV UNEARTHED

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 12: AECMSA Electrical Cable Price Variation Factors

PAGE 9

RATED COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREA

mm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVING

COMBINED COMBINED

16 0.046* - 0.183 0.101 0.138 0.054 0.087 0.046* - 0.222 0.140 0.189 0.065 0.106 16

25 0.072 0.022 0.183 0.090 0.136 0.054 0.006 0.072 0.022 0.221 0.144 0.189 0.064 0.105 25

35 0.100 0.031 0.205 0.134 0.183 0.060 0.102 0.100 0.031 0.256 0.147 0.201 0.067 0.112 35

50 0.144 0.044 0.245 0.145 0.198 0.066 0.110 0.144 0.044 0.276 0.156 0.214 0.077 0.186 50

70 0.201 0.062 0.277 0.155 0.212 0.076 0.122 0.201 0.062 0.319 0.168 0.229 0.084 0.142 70

95 0.273 0.084 0.308 0.167 0.239 0.084 0.141 0.273 0.084 0.372 0.180 0.245 0.092 0.151 95

120 0.344 0.106 0.366 0.178 0.245 0.092 0.150 0.344 0.106 0.404 0.190 0.330 0.098 0.160 120

150 0.431 0.132 0.393 0.188 0.329 0.098 0.159 0.431 0.132 0.461 0.201 0.350 0.104 0.175 150

185 0.531 0.163 0.465 0.201 0.349 0.103 0.168 0.531 0.163 0.540 0.215 0.372 0.111 0.188 185

240 0.689 0.211 0.541 0.218 0.378 0.112 0.192 0.689 0.211 0.583 0.230 0.398 0.118 0.202 240

300 0.861 0.264 0.633 0.237 0.464 0.123 0.208 0.861 0.264 0.672 0.248 0.484 0.127 0.217 300

400 - 0.353 0.750 0.264 0.497 0.131 0.225 - 0.353 0.781 0.275 0.517 0.134 0.231 400

500 - 0.441 0.860 0.289 0.612 0.140 0.240 - 0.441 0.907 0.296 0.632 0.145 0.250 500*Circular conductors

PAGE 9

STEEL PVC STEEL PVC

11kV GENERAL PURPOSE FULLY IMPREGNATED BELTED CABLES TO SANS 97 TABLES 17 & 18

6,35/11kV EARTHED 11/11kV UNEARTHED

3 CORE TABLE 17 3 CORE TABLE 18

Printed 2007/06/13

Page 13: AECMSA Electrical Cable Price Variation Factors

PAGE 10

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.204 0.132 0.178 0.059 0.100 16

25 - - - - 0.072 0.022 0.202 0.141 0.188 0.056 0.097 25

35 - - - - 0.100 0.031 0.214 0.147 0.196 0.063 0.104 35

50 - - - - 0.144 0.044 0.245 0.159 0.207 0.067 0.113 50

70 - - - - 0.201 0.062 0.298 0.164 0.215 0.078 0.125 70

95 - - - - 0.273 0.084 0.314 0.175 0.231 0.088 0.144 95

120 - - - - 0.344 0.106 0.382 0.193 0.251 0.093 0.152 120

150 0.142 0.044 0.177 0.029 0.431 0.132 0.434 0.198 0.334 0.100 0.163 150

185 0.175 0.053 0.202 0.035 0.531 0.163 0.464 0.209 0.351 0.105 0.177 185

240 0.228 0.070 0.221 0.038 0.689 0.211 0.523 0.230 0.386 0.114 0.194 240

300 0.284 0.087 0.267 0.045 0.861 0.264 0.645 0.256 0.467 0.124 0.211 300

400 0.379 0.117 0.309 0.049 - 0.353 0.770 0.269 0.544 0.132 0.227 400

500 0.474 0.146 0.362 0.058 - 0.441 0.887 0.289 0.617 0.142 0.244 500

630 0.598 0.183 0.434 0.068 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 10

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 TABLES 10 & 19.

6,35/11kV EARTHED

SINGLE CORE TABLE 10 3 CORE TABLE 19

Printed 2007/06/13

Page 14: AECMSA Electrical Cable Price Variation Factors

PAGE 11

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.276 0.161 0.211 0.076 0.122 16

25 - - - - 0.072 0.022 0.275 0.159 0.217 0.075 0.121 25

35 - - - - 0.100 0.031 0.309 0.169 0.228 0.078 0.126 35

50 - - - - 0.144 0.044 0.326 0.180 0.230 0.088 0.144 50

70 - - - - 0.201 0.062 0.382 0.191 0.249 0.093 0.153 70

95 - - - - 0.273 0.084 0.444 0.199 0.334 0.100 0.164 95

120 - - - - 0.344 0.106 0.477 0.207 0.354 0.105 0.177 120

150 0.142 0.044 0.224 0.037 0.431 0.132 0.546 0.221 0.376 0.112 0.191 150

185 0.175 0.053 0.235 0.039 0.531 0.163 0.580 0.236 0.390 0.117 0.200 185

240 0.228 0.070 0.268 0.045 0.689 0.211 0.673 0.246 0.477 0.209 0.213 240

300 0.284 0.087 0.308 0.054 0.861 0.264 0.771 0.273 0.517 0.134 0.230 300

400 0.379 0.117 0.359 0.058 - 0.353 0.897 0.292 0.627 0.143 0.246 400

500 0.474 0.146 0.419 0.067 - 0.441 1.021 0.313 0.668 0.152 0.261 500

630 0.598 0.183 0.453 0.078 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 11

11kV SCREENED TYPE FULLY IMPREGNATED GENERAL PURPOSE CABLES TO SANS 97 AFAA.

11/11kV UNEARTHED

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 15: AECMSA Electrical Cable Price Variation Factors

PAGE 12

RATED COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREA

mm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVING

COMBINED COMBINED

16 0.046* - 0.233 0.137 0.197 0.066 0.111 0.046* - 0.308 0.167 0.219 0.079 0.129 16

25 0.072 0.022 0.232 0.155 0.200 0.066 0.110 0.072 0.022 0.305 0.172 0.228 0.078 0.128 25

35 0.100 0.031 0.267 0.156 0.213 0.071 0.120 0.100 0.031 0.319 0.171 0.231 0.080 0.131 35

50 0.144 0.144 0.309 0.172 0.228 0.078 0.129 0.144 0.044 0.371 0.191 0.245 0.092 0.150 50

70 0.201 0.062 0.360 0.178 0.231 0.090 0.146 0.201 0.062 0.397 0.195 0.325 0.098 0.160 70

95 0.273 0.084 0.381 0.190 0.292 0.096 0.155 0.273 0.084 0.466 0.208 0.351 0.104 0.176 95

120 0.344 0.106 0.452 0.201 0.337 0.101 0.165 0.344 0.106 0.539 0.220 0.367 0.110 0.188 120

150 0.431 0.132 0.475 0.206 0.357 0.106 0.180 0.431 0.132 0.558 0.232 0.385 0.116 0.196 150

185 0.531 0.163 0.549 0.222 0.379 0.112 0.192 0.531 0.163 0.645 0.243 0.463 0.122 0.207 185

240 0.689 0.211 0.637 0.247 0.460 0.122 0.206 0.689 0.211 0.749 0.260 0.496 0.129 0.221 240

300 0.861 0.264 0.739 0.268 0.494 0.130 0.223 0.861 0.264 0.841 0.280 0.529 0.138 0.242 300

400 - 0.353 0.864 0.287 0.602 0.139 0.238 - 0.353 0.979 0.300 0.638 0.147 0.252 400

500 - 0.441 0.978 0.306 0.648 0.148 0.255 - 0.441 1.112 0.321 0.679 0.155 0.269 500*Circular conductors

PAGE 12

STEEL PVC STEEL PVC

11kV DRAINED GENERAL PURPOSE (BELTED) CABLES FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED-CABLES

WITH AUGMENTED DIELECTRIC TO SANS 97 AFAA

6,35/11kV EARTHED 11/11kV UNEARTHED

3 CORE 3 CORE

Printed 2007/06/13

Page 16: AECMSA Electrical Cable Price Variation Factors

PAGE 13

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD PVC RATED

AREA SERVING DSTA SWA SERVING BEDDING SERVING AREA

mm2 OVER OVER & OVER mm2

ARMOUR ARMOUR SERVING ARMOUR

COMBINED

16 - - - - 0.046* - 0.232 0.146 0.199 0.066 0.111 - - - - 16

25 - - - - 0.072 0.022 0.231 0.155 0.199 0.065 0.108 - - - - 25

35 - - - - 0.100 0.031 0.267 0.156 0.211 0.071 0.119 - - - - 35

50 - - - - 0.144 0.044 0.308 0.166 0.228 0.078 0.126 - - - - 50

70 - - - - 0.201 0.062 0.361 0.179 0.246 0.089 0.146 - - - - 70

95 - - - - 0.273 0.084 0.386 0.191 0.319 0.096 0.155 - - - - 95

120 - - - - 0.344 0.106 0.454 0.198 0.327 0.101 0.164 - - - - 120

150 0.142 0.044 0.192 0.035 0.431 0.132 0.477 0.212 0.357 0.106 0.179 0.142 0.044 0.255 0.043 150

185 0.175 0.053 0.224 0.037 0.531 0.163 0.549 0.220 0.379 0.112 0.192 0.175 0.053 0.267 0.045 185

240 0.228 0.070 0.256 0.043 0.689 0.211 0.634 0.244 0.460 0.122 0.206 0.228 0.070 0.308 0.048 240

300 0.284 0.087 0.293 0.047 0.861 0.264 0.734 0.263 0.497 0.130 0.222 0.284 0.087 0.359 0.058 300

400 0.379 0.117 0.320 0.055 - 0.353 0.867 0.283 0.607 0.139 0.238 - - - - 400

500 0.474 0.146 0.371 0.060 - 0.441 1.001 0.276 0.648 0.148 0.255 0.474 0.146 0.456 0.070 500

630 0.598 0.183 0.442 0.069 - - - - - - - 0.598 0.183 0.536 0.083 630

STEEL PVC

* Circular conductors

PAGE 13

11 kV SCREENED TYPE DRAINED GENERAL PURPOSE CABLE FOR NORMAL SERVICE CONDITIONS & 11kV FULLY IMPREGNATED CABLES WITH

AUGMENTED DIELECTRIC TO SANS 97 AFAA

6,35/11kV 11/11kV

SINGLE CORE 3 CORE SINGLE CORE

Printed 2007/06/13

Page 17: AECMSA Electrical Cable Price Variation Factors

PAGE 14

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

25 - - - - 0.072* 0.022* 0.400 0.194 0.322 0.096 0.167 25

35 - - - - 0.100* 0.031* 0.459 0.205 0.341 0.099 0.175 35

50 - - - - 0.144 0.044 0.413 0.204 0.341 0.101 0.172 50

70 - - - - 0.201 0.062 0.481 0.217 0.364 0.107 0.189 70

95 - - - - 0.273 0.084 0.553 0.233 0.390 0.114 0.198 95

120 - - - - 0.344 0.106 0.584 0.243 0.399 0.120 0.208 120

150 0.162 0.064 0.232 0.040 0.431 0.132 0.662 0.249 0.470 0.125 0.218 150

185 0.175 0.053 0.261 0.044 0.531 0.163 0.694 0.261 0.495 0.126 0.229 185

240 0.228 0.070 0.296 0.047 0.689 0.211 0.800 0.274 0.526 0.131 0.246 240

300 0.284 0.087 0.361 0.057 0.861 0.264 0.907 0.293 0.622 0.143 0.261 300

400 0.379 0.117 0.379 0.066 1.148 0.353 1.045 0.313 0.668 - - 400

500 0.474 0.146 0.445 0.074 1.436 0.441 1.171 0.361 0.710 - - 500

630 0.598 0.183 0.485 0.085 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 14

12,7/22kV GENERAL PURPOSE IMPREGNATED SCREENED CABLES TO SANS 97 TABLES 11 & 20

12,7/22kV

SINGLE CORE TABLE 11 3 CORE TABLE 20

Printed 2007/06/13

Page 18: AECMSA Electrical Cable Price Variation Factors

PAGE 15

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

10 - - - - 0.019* - 0.097 0.064 0.081 0.027 0.039 10

16 - - - - 0.031* - 0.109 0.067 0.087 0.032 0.044 16

25 - - - - 0.048 0.014 0.124 0.073 0.095 0.034 0.048 25

35 - - - - 0.067 0.021 0.150 0.098 0.103 0.040 0.063 35

50 - - - - 0.095 0.030 0.168 0.107 0.111 0.042 0.070 50

70 - - - - 0.134 0.041 0.196 0.116 0.152 0.153 0.084 70

95 - - - - 0.181 0.055 0.245 0.127 0.168 0.055 0.093 95

120 - - - - 0.230 0.071 0.256 0.135 0.176 0.062 0.102 120

150 0.142 0.044 0.187 0.023 0.287 0.088 0.316 0.148 0.231 0.070 0.122 150

185 0.175 0.053 0.202 0.027 0.354 0.109 0.338 0.157 0.263 0.077 0.128 185

240 0.228 0.070 0.234 0.030 0.459 0.141 0.414 0.174 0.292 0.090 0.146 240

300 0.284 0.087 0.298 0.037 0.574 0.176 0.488 0.191 0.320 0.098 0.165 300

400 0.379 0.117 0.330 0.045 - 0.235 0.581 0.208 0.347 0.106 0.180 400

500 0.474 0.146 0.375 0.055 - 0.294 0.688 0.231 0.386 0.117 0.200 500

630 0.598 0.183 0.465 0.059 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 15

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA

SINGLE CORE 2 CORE

Printed 2007/06/13

Page 19: AECMSA Electrical Cable Price Variation Factors

PAGE 16

RATED COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREA

mm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVING

COMBINED COMBINED

10 0.029* - 0.129 0.074 0.094 0.037 0.048 0.038* - 0.139 0.098 0.099 0.036 0.062 10

16 0.046* - 0.143 0.103 0.104 0.039 0.064 0.062* - 0.167 0.109 0.114 0.040 0.066 16

25 0.072 0.022 0.153 0.100 0.107 0.040 0.064 0.095 0.030 0.183 0.111 0.114 0.043 0.074 25

35 0.100 0.031 0.179 0.109 0.115 0.043 0.071 0.134 0.041 0.202 0.119 0.160 0.051 0.085 35

50 0.144 0.044 0.198 0.118 0.157 0.051 0.085 0.191 0.058 0.245 0.132 0.174 0.056 0.097 50

70 0.201 0.062 0.245 0.129 0.173 0.056 0.095 0.268 0.082 0.302 0.141 0.194 0.066 0.110 70

95 0.273 0.084 0.275 0.141 0.188 0.064 0.106 0.364 0.112 0.340 0.158 0.269 0.078 0.129 95

120 0.344 0.106 0.318 0.152 0.241 0.072 0.124 0.459 0.140 0.402 0.172 0.289 0.089 0.145 120

150 0.431 0.132 0.383 0.166 0.272 0.083 0.141 0.574 0.176 0.474 0.189 0.312 0.097 0.163 150

185 0.531 0.163 0.423 0.177 0.296 0.091 0.148 0.708 0.217 0.558 0.203 0.340 0.103 0.175 185

240 0.689 0.211 0.508 0.197 0.328 0.100 0.169 0.918 0.282 0.672 0.228 0.379 0.114 0.196 240

300 0.861 0.264 0.603 0.219 0.366 0.111 0.188 1.148 0.353 0.793 0.251 0.483 0.126 0.215 300

400 - 0.353 0.715 0.239 0.424 0.121 0.205 - 0.470 0.937 0.275 0.533 0.137 0.234 400

500 - 0.441 0.854 0.263 0.504 0.131 0.225 - 0.588 1.095 0.300 0.643 0.147 0.254 500* Circular conductors

PAGE 16

STEEL PVC STEEL PVC

1000V LOW TENSION HEAVY DUTY CABLES TO SANS 97 AFAA

3 CORE 4 CORE

Printed 2007/06/13

Page 20: AECMSA Electrical Cable Price Variation Factors

PAGE 17

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.238 0.117 0.154 0.048 0.084 16

25 - - - - 0.072 0.022 0.229 0.116 0.152 0.048 0.083 25

35 - - - - 0.100 0.031 0.246 0.123 0.162 0.053 0.088 35

50 - - - - 0.144 0.044 0.269 0.131 0.174 0.059 0.100 50

70 - - - - 0.201 0.062 0.299 0.142 0.187 0.065 0.106 70

95 - - - - 0.273 0.084 0.329 0.154 0.257 0.076 0.126 95

120 - - - - 0.344 0.106 0.391 0.165 0.277 0.083 0.140 120

150 0.142 0.044 0.235 0.028 0.431 0.132 0.415 0.176 0.296 0.091 0.147 150

185 0.175 0.053 0.256 0.029 0.531 0.163 0.487 0.189 0.316 0.097 0.163 185

240 0.228 0.070 0.275 0.036 0.689 0.211 0.570 0.206 0.343 0.105 0.176 240

300 0.284 0.087 0.306 0.039 0.861 0.264 0.666 0.228 0.379 0.114 0.198 300

400 0.379 0.117 0.339 0.046 - 0.353 0.793 0.247 0.481 0.125 0.212 400

500 0.474 0.146 0.400 0.055 - 0.441 0.905 0.268 0.507 0.133 0.229 500

630 0.598 0.183 0.441 0.060 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 17

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 AFAA

1,9/3,3kV

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 21: AECMSA Electrical Cable Price Variation Factors

PAGE 18

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.240 0.118 0.163 0.053 0.087 16

25 - - - - 0.072 0.022 0.246 0.117 0.161 0.051 0.086 25

35 - - - - 0.100 0.031 0.264 0.124 0.170 0.055 0.093 35

50 - - - - 0.144 0.044 0.286 0.133 0.183 0.063 0.102 50

70 - - - - 0.201 0.062 0.315 0.144 0.197 0.066 0.111 70

95 - - - - 0.273 0.084 0.348 0.155 0.270 0.078 0.129 95

120 - - - - 0.344 0.106 0.402 0.166 0.291 0.085 0.143 120

150 0.142 0.044 0.245 0.029 0.431 0.132 0.431 0.180 0.308 0.093 0.151 150

185 0.175 0.053 0..267 0.030 0.531 0.163 0.498 0.192 0.327 0.099 0.167 185

240 0.228 0.070 0.287 0.037 0.689 0.211 0.587 0.212 0.354 0.108 0.184 240

300 0.284 0.087 0.319 0.044 0.861 0.264 0.685 0.232 0.386 0.117 0.200 300

400 0.379 0.117 0.380 0.048 - 0.353 0.814 0.251 0.489 0.126 0.215 400

500 0.474 0.146 0.413 0.056 - 0.441 0.927 0.277 0.519 0.135 0.232 500

630 0.598 0.183 0.453 0.066 - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 18

3,3kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 22

3,3/3,3kV

SINGLE CORE 3 CORE TABLE 22

Printed 2007/06/13

Page 22: AECMSA Electrical Cable Price Variation Factors

PAGE 19

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.264 0.130 0.177 0.056 0.096 16

25 - - - - 0.072 0.022 0.265 0.129 0.175 0.055 0.095 25

35 - - - - 0.100 0.031 0.288 0.134 0.180 0.063 0.102 35

50 - - - - 0.144 0.044 0.310 0.142 0.191 0.066 0.111 50

70 - - - - 0.201 0.062 0.340 0.155 0.272 0.077 0.127 70

95 - - - - 0.273 0.084 0.398 0.169 0.294 0.084 0.142 95

120 - - - - 0.344 0.106 0.433 0.179 0.299 0.092 0.150 120

150 0.142 0.054 0.256 0.030 0.431 0.132 0.508 0.191 0.319 0.098 0.165 150

185 0.175 0.065 0.276 0.035 0.531 0.163 0.560 0.203 0.340 0.103 0.175 185

240 0.228 0.085 0.298 0.038 0.689 0.211 0.624 0.221 0.370 0.112 0.191 240

300 0.284 0.106 0.350 0.045 0.861 0.264 0.715 0.241 0.427 0.122 0.208 300

400 0.379 0.143 0.382 0.048 - 0.353 0.841 0.260 0.501 0.130 0.224 400

500 0.474 0.178 0.420 0.057 - 0.441 0.969 0.282 0.597 0.140 0.240 500

630 0.598 0.224 0.484 0.067 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 19

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 13 & 23

3,8/6,6kV

SINGLE CORE TABLE 13 3 CORE TABLE 23

Printed 2007/06/13

Page 23: AECMSA Electrical Cable Price Variation Factors

PAGE 20

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.292 0.139 0.187 0.064 0.104 16

25 - - - - 0.072 0.022 0.290 0.138 0.187 0.063 0.103 25

35 - - - - 0.100 0.031 0.308 0.142 0.195 0.066 0.105 35

50 - - - - 0.144 0.044 0.339 0.151 0.263 0.076 0.126 50

70 - - - - 0.201 0.062 0.390 0.163 0.285 0.084 0.141 70

95 - - - - 0.273 0.084 0.424 0.174 0.304 0.092 0.149 95

120 - - - - 0.344 0.106 0.485 0.186 0.325 0.098 0.164 120

150 0.142 0.044 0.276 0.036 0.431 0.132 0.520 0.195 0.340 0.102 0.172 150

185 0.175 0.053 0.298 0.038 0.531 0.163 0.599 0.209 0.363 0.109 0.185 185

240 0.228 0.070 0.315 0.044 0.689 0.211 0.696 0.232 0.386 0.117 0.200 240

300 0.284 0.087 0.382 0.048 0.861 0.264 0.799 0.251 0.485 0.126 0.215 300

400 0.379 0.117 0.411 0.056 - 0.353 0.929 0.272 0.518 0.135 0.232 400

500 0.474 0.146 0.475 0.065 - 0.441 1.065 0.291 0.617 0.144 0.248 500

630 0.598 0.183 0.558 0.070 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 20

6,6kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLE 24

3,8/6,6kV

SINGLE CORE 3 CORE TABLE 24

Printed 2007/06/13

Page 24: AECMSA Electrical Cable Price Variation Factors

PAGE 21

RATED COPPER ALUMINIUM LEAD COPPER ALUMINIUM LEAD RATED

AREA DSTA SWA SERVING BEDDING DSTA SWA SERVING BEDDING AREA

mm2 OVER & OVER & mm2

ARMOUR SERVING ARMOUR SERVING

COMBINED COMBINED

16 0.046* - 0.319 0.150 0.257 0.071 0.123 0.046* - 0.391 0.168 0.290 0.085 0.142 16

25 0.072 0.022 0.319 0.159 0.268 0.071 0.122 0.072 0.022 0.390 0.171 0.296 0.084 0.141 25

35 0.100 0.031 0.348 0.161 0.277 0.077 0.128 0.100 0.031 0.423 0.183 0.309 0.090 0.146 35

50 0.144 0.044 0.402 0.180 0.296 0.084 0.141 0.144 0.044 0.475 0.189 0.325 0.096 0.161 50

70 0.201 0.062 0.433 0.181 0.305 0.092 0.149 0.201 0.062 0.509 0.195 0.334 0.100 0.169 70

95 0.273 0.084 0.498 0.192 0.325 0.098 0.165 0.273 0.084 0.592 0.209 0.360 0.108 0.183 95

120 0.344 0.106 0.528 0.205 0.341 0.102 0.173 0.344 0.106 0.623 0.218 0.373 0.111 0.190 120

150 0.431 0.132 0.600 0.212 0.367 0.109 0.186 0.431 0.132 0.696 0.230 0.393 0.118 0.200 150

185 0.531 0.163 0.677 0.231 0.385 0.114 0.195 0.531 0.163 0.737 0.247 0.473 0.123 0.209 185

240 0.689 0.211 0.737 0.241 0.472 0.123 0.209 0.689 0.211 0.855 0.263 0.504 0.130 0.223 240

300 0.861 0.264 0.865 0.265 0.501 0.131 0.225 0.861 0.264 0.961 0.283 0.607 0.139 0.238 300

400 - 0.353 0.980 0.286 0.612 0.140 0.240 - 0.353 1.092 0.305 0.638 0.148 0.255 400

500 - 0.441 1.171 0.310 0.638 0.150 0.258 - 0.441 1.232 0.326 0.690 0.160 0.275 500* Circular conductors

PAGE 21

3 CORE TABLE 25 3 CORE TABLE 26

STEEL PVC STEEL PVC

11kV HEAVY DUTY (BELTED) CABLES TO SANS 97 TABLES 25 & 26

6,35/11kV EARTHED 11/11kV UNEARTHED

Printed 2007/06/13

Page 25: AECMSA Electrical Cable Price Variation Factors

PAGE 22

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.317 0.155 0.265 0.071 0.123 16

25 - - - - 0.072 0.022 0.316 0.160 0.271 0.070 0.122 25

35 - - - - 0.100 0.031 0.340 0.166 0.283 0.077 0.127 35

50 - - - - 0.144 0.044 0.391 0.173 0.302 0.084 0.141 50

70 - - - - 0.201 0.062 0.423 0.183 0.321 0.092 0.149 70

95 - - - - 0.273 0.084 0.497 0.195 0.330 0.098 0.165 95

120 - - - - 0.344 0.106 0.524 0.204 0.341 0.102 0.172 120

150 0.142 0.044 0.277 0.038 0.431 0.132 0.601 0.218 0.369 0.109 0.185 150

185 0.175 0.053 0.297 0.039 0.531 0.163 0.676 0.231 0.409 0.114 0.195 185

240 0.228 0.070 0.315 0.046 0.689 0.211 0.735 0.247 0.474 0.123 0.208 240

300 0.284 0.087 0.301 0.054 0.861 0.264 0.843 0.267 0.507 0.131 0.225 300

400 0.379 0.117 0.412 0.059 - 0.353 0.970 0.286 0.607 0.140 0.240 400

500 0.474 0.146 0.482 0.067 - 0.441 1.108 0.309 0.653 0.149 0.257 500

630 0.598 0.183 0.562 0.080 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 22

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 TABLES 14 & 27

6,35/11kV

SINGLE CORE TABLE 14 3 CORE TABLE 27

Printed 2007/06/13

Page 26: AECMSA Electrical Cable Price Variation Factors

PAGE 23

RATED COPPER ALUMINIUM LEAD PVC COPPER ALUMINIUM LEAD RATED

AREA SERVING DSTA SWA SERVING BEDDING AREA

mm2 OVER OVER & mm2

ARMOUR ARMOUR SERVING

COMBINED

16 - - - - 0.046* - 0.465 0.191 0.322 0.096 0.158 16

25 - - - - 0.072 0.022 0.476 0.195 0.328 0.095 0.156 25

35 - - - - 0.100 0.031 0.498 0.202 0.338 0.098 0.162 35

50 - - - - 0.144 0.044 0.516 0.211 0.354 0.102 0.169 50

70 - - - - 0.201 0.062 0.601 0.228 0.376 0.109 0.185 70

95 - - - - 0.273 0.084 0.674 0.241 0.394 0.114 0.195 95

120 - - - - 0.344 0.106 0.719 0.251 0.411 0.119 0.203 120

150 0.142 0.044 0.329 0.046 0.431 0.132 0.801 0.257 0.485 0.125 0.213 150

185 0.175 0.053 0.340 0.048 0.531 0.163 0.855 0.263 0.496 0.130 0.222 185

240 0.228 0.070 0.401 0.058 0.689 0.211 0.960 0.281 0.533 0.138 0.236 240

300 0.284 0.087 0.466 0.060 0.861 0.264 1.070 0.303 0.638 0.146 0.251 300

400 0.379 0.117 0.497 0.069 - 0.353 1.213 0.323 0.679 0.155 0.268 400

500 0.474 0.146 0.567 0.080 - 0.441 1.365 0.342 0.721 0.164 0.284 500

630 0.598 0.183 0.614 0.086 - - - - - - - 630

STEEL PVC

*Circular conductors

PAGE 23

11kV HEAVY DUTY SCREENED CABLES TO SANS 97 AFAA

11/11kV

SINGLE CORE 3 CORE

Printed 2007/06/13

Page 27: AECMSA Electrical Cable Price Variation Factors

PAGE 24

RATED RATED

AREA AREA

mm2 COPPER STEEL* PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

1,5 0.001 - - 0.003 0.016* 0.017* 0.004 0.017* 0.019* 0.006 0.018* 0.021* 1,5

- - - 0.023# 0.018 - 0.025# 0.020# - 0.027# 0.024#

2,5 0.002 - - 0.005 0.018* 0.020* 0.007 0.019* 0.022* 0.010 0.025* 0.025* 2,5

- - - 0.028# 0.022# - 0.029# 0.025# - 0.032# 0.028#

4 0.004 - - 0.008 0.022* 0.025* 0.011 0.022* 0.027* 0.015 0.034* 0.032* 4

- - - 0.030# 0.026# - 0.032# 0.028# - 0.035# 0.034#

6 0.006 - - 0.011 0.032 0.029 0.017 0.034 0.032 0.023 0.037 0.036 6

10 0.009 - - 0.019 0.037 0.036 0.029 0.039 0.039 0.038 0.043 0.044 10

16 0.015 0.016 0.016 0.031 0.039 0.044 0.046 0.059 0.051 0.062 0.066 0.060 16

25 0.024 0.018 0.020 0.048 0.043 0.038 0.072 0.066 0.053 0.095 0.073 0.062 25

35 0.033 0.030 0.022 0.067 0.058 0.040 0.100 0.072 0.059 0.134 0.103 0.071 35

50 0.047 0.034 0.028 0.095 0.073 0.056 0.144 0.104 0.072 0.191 0.118 0.095 50

70 0.067 0.038 0.033 0.134 0.101 0.065 0.201 0.116 0.087 0.268 0.133 0.111 70

95 0.090 0.058 0.043 0.181 0.115 0.079 0.273 0.132 0.110 0.364 0.151 0.133 95

120 0.114 0.064 0.047 0.230 0.124 0.090 0.344 0.142 0.121 0.459 0.209 0.156 120

150 0.142 0.070 0.055 - - - 0.431 0.157 0.140 0.574 0.230 0.187 150

185 0.175 0.094 0.061 - - - 0.531 0.213 0.172 0.708 0.251 0.217 185

240 0.228 0.107 0.077 - - - 0.609 0.247 0.210 0.918 0.355 0.270 240

300 0.284 0.117 0.090 - - - 0.861 0.351 0.257 1.148 0.398 0.326 300

400 0.379 0.132 0.109 - - - - - - - - - 400

500 0.474 0.145 0.124 - - - - - - - - - 500

630 0.598 - - - - - - - - - - - 630

800 0.759 - - - - - - - - - - - 800

1000 0.948 - - - - - - - - - - - 1000

PAGE 24

∗DC CIRCUITS ONLY * 0,9 MM SWA

# 1,25 MM SWA

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

NUMBER OF CORES

1 2 3 4

Printed 2007/06/13

Page 28: AECMSA Electrical Cable Price Variation Factors

PAGE 25

RATED RATED

AREA 5 6 7 8 9 AREA

mm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

0,75 0.0036 0.015* 0.017* 0.0043 0.017* 0.017* 0.0050 0.017* 0.017* 0.0057 0.018* 0.019* 0.0065 0.019* 0.021* 0,75

0.027# 0.019# 0.029# 0.022# 0.031# 0.023# 0.033# 0.024# 0.035# 0.026*

1.0 0.0048 0.017* 0.018* 0.0058 0.017* 0.018* 0.0068 0.019* 0.021* 0.0078 0.019* 0.021* 0.0087 0.021* 0.022* 1.0

0.029# 0.020* 0.031# 0.024# 0.033# 0.026# 0.035* 0.028# 0.037# 0.027*

1,5 0.0073 0.024* 0.024* 0.0087 0.031* 0.026* 0.0102 0.031* 0.027* 0.0110 0.034* 0.030* 0.0130 0.037* 0.035* 1,5

0.031# 0.027# 0.033# 0.030# 0.035# 0.030# 0.037# 0.033# 0.040# 0.037*

2,5 0.0120 0.034 0.030 0.0140 0.035 0.033 0.0170 0.036 0.034 0.0190 0.039 0.038 0.0220 0.048 0.041 2,5

4 0.0190 0.037 0.037 0.0240 0.040 0.039 0.0270 0.041 0.040 0.0310 0.060 0.053 0.0350 0.066 0.056 4

6 0.0290 0.040 0.040 0.0350 0.060 0.047 0.0400 0.062 0.053 0.0460 0.062 0.056 0.0520 0.071 0.060 6

10 0.0480 0.060 0.056 0.0570 0.066 0.060 0.0680 0.069 0.064 0.0770 0.089 0.063 0.0860 0.101 0.068 10

16 0.0770 0.072 0.070 0.0920 0.094 0.076 0.1080 0.098 0.079 0.1230 0.101 0.078 0.1380 0.118 0.088 16

RATED RATED

AREA 10 12 14 16 19 AREA

mm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

0,75 0.0072 0.030 0.024 0.0086 0.031 0.025 0.0102 0.033 0.028 0.0110 0.034 0.032 0.0130 0.036 0.034 0,75

1.0 0.0097 0.035 0.028 0.0110 0.036 0.030 0.0130 0.036 0.030 0.0150 0.036 0.033 0.0180 0.038 0.036 1.0

1,5 0.0140 0.040 0.035 0.0170 0.041 0.038 0.0210 0.043 0.044 0.0240 0.059 0.051 0.0280 0.060 0.056 1,5

2,5 0.0250 0.062 0.048 0.0290 0.064 0.053 0.0340 0.067 0.057 0.0390 0.071 0.061 0.0460 0.093 0.071 2,5

4 0.0390 0.069 0.060 0.0460 0.071 0.062 0.0540 0.095 0.070 0.0620 0.100 0.077 0.0730 0.112 0.085 4

6 0.0570 0.096 0.063 0.0700 0.100 0.068 - - - - - - - - - 6

10 0.0960 0.109 0.078 Q.116 0.110 0.088 - - - - - - - - - 10

16 0.1540 0.122 0.100 0.1850 0.127 0.109 - - - - - - - - - 16* 0,9mm SWA

# 1,25mm SWA

PAGE 25

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

NUMBER OF CORES

NUMBER OF CORES

Printed 2007/06/13

Page 29: AECMSA Electrical Cable Price Variation Factors

PAGE 26

RATED RATED

AREA 20 21 24 27 AREA

mm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

0,75 0.014 0.037 0.036 0.015 0.038 0.037 0.017 0.057 0.046 0.019 0.058 0.049 0,75

1.0 0.019 0.039 0.038 0.021 0.040 0.039 0.024 0.060 0.049 0.027 0.060 0.053 1.0

1,5 0.029 0.068 0.059 0.031 0.068 0.063 0.035 0.094 0.069 0.039 0.096 0.075 1,5

2,5 0.048 0.098 0.077 0.051 0.098 0.083 0.058 0.109 0.088 0.066 0.114 0.097 2,5

4 0.077 0.112 0.091 0.081 0.112 0.100 0.092 0.125 0.110 0.104 0.128 0.121 4

RATED RATED

AREA AREA

mm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

0,75 0.022 0.060 0.053 0.024 0.062 0.056 0.027 0.066 0.060 0.044 0.101 0.087 0,75

1.0 0.029 0.064 0.056 0.032 0.066 0.059 0.036 0.069 0.063 0.059 0.107 0.096 1.0

1,5 0.044 0.099 0.080 0.048 0.099 0.085 0.053 0.108 0.091 0.088 0.134 0.135 1,5

2,5 0.073 0.117 0.105 0.080 0.117 0.113 0.090 0.127 0.123 0.148 0.193 0.188 2,5

4 0.116 0.132 0.129 0.127 0.137 0.139 0.142 0.144 0.148 0.235 0.217 0.221 4

PAGE 26

NUMBER OF CORES

30 33 37 61

600/1000V PVC PVC SWA PVC CABLES TO SANS 1507

NUMBER OF CORES

Printed 2007/06/13

Page 30: AECMSA Electrical Cable Price Variation Factors

PAGE 27

RATED RATED

AREA AREA

mm2 COPPER STEEL PVC COPPER STEEL PVC COPPER STEEL PVC mm2

1,5 0.0051 0.014° 0.017° 0.0065 0.015° 0.019° 0.0079 0.017° 0.021° 1,5

- 0.021* 0.018* - 0.023* 0.020* - 0.025* 0.024*

2,5 0.0081 0.016° 0.020° 0.0110 0.017° 0.022° 0.0130 0.018° 0.025° 2,5

- 0.023* 0.022* - 0.024* 0.025* - 0.027* 0.028*

4 0.0130 0.016° 0.025° 0.0160 0.017° 0.027° 0.0200 0.029° 0.032° 4

- 0.025* 0.026* - 0.027* 0.028* - 0.030* 0.034*

6 0.0180 0.026 0.029 0.0250 0.028 0.032 0.0290 0.030 0.036 6

10 0.0320 0.026 0.036 0.0410 0.028 0.039 0.0490 0.031 0.044 10

16 0.0480 0.026 0.044 0.0660 0.044 0.051 0.0790 0.045 0.060 16

25 0.0660 0.026 0.038 0.0910 0.045 0.053 0.1120 0.052 0.062 25

35 0.0860 0.036 0.048 0.1200 0.051 0.059 0.1490 0.080 0.071 35

50 0.1250 0.043 0.056 0.1740 0.073 0.072 0.2170 0.085 0.095 50

70 0.1740 0.063 0.065 0.2410 0.076 0.087 0.3010 0.091 0.111 70

95 0.2410 0.059 0.079 0.3320 0.077 0.110 0.4130 0.092 0.133 95

120 0.3120 0.049 0.090 0.4260 0.068 0.121 0.5300 0.127 0.156 120

150 - - - 0.5130 0.082 0.140 0.6420 0.147 0.187 150

185 - - - 0.6450 0.114 0.172 0.8020 0.143 0.217 185

240 - - - 0.8330 0.123 0.210 1.0390 0.213 0.270 240

300 - - - 1.0380 0.190 0.257 1.2930 0.225 0.326 300° 0.9mm SWA

* 1.25mm SWA

PAGE 27

600/1000V PVC PVC SWA/ECC PVC CABLES TO SANS 1507-1990

NUMBER OF CORES

2 3 4

Printed 2007/06/13

Page 31: AECMSA Electrical Cable Price Variation Factors

PAGE 28

COPPER STEEL PVC

16 0.046 0.099 0.095 16

25 0.072 0.104 0.086 25

35 0.100 0.111 0.096 35

50 0.144 0.122 0.110 50

70 0.201 0.134 0.126 70

95 0.273 0.147 0.142 95

120 0.344 0.157 0.155 120

150 0.431 0.213 0.180 150

185 0.531 0.228 0.200 185

240 0.689 0.251 0.227 240

300 0.861 0.346 0.257 300

PAGE 28

1,9/3,3kV 3 CORE PVC PVC SWA PVC CABLES TO SANS 1507

RATED

AREA

mm2

1,9/3,3kV RATED

AREA

mm2

Printed 2007/06/13

Page 32: AECMSA Electrical Cable Price Variation Factors

PAGE 29

STRANDED

ALUMINIUMSTEEL* PVC

STRANDED

ALUMINIUMSTEEL PVC

STRANDED

ALUMINIUMSTEEL PVC

STRANDED

ALUMINIUMSTEEL PVC

25 0.0073 0.018 0.020 0.0147 0.043 0.038 0.0220 0.066 0.053 0.0300 0.073 0.062 25

35 0.0102 0.030 0.022 0.0210 0.058 0.048 0.0310 0.072 0.059 0.0410 0.103 0.071 35

50 0.0145 0.034 0.02B 0.0300 0.073 0.056 0.0440 0.104 0.072 0.0580 0.118 0.095 50

70 0.0210 0.038 0.033 0.0410 0.101 0.065 0.0620 0.116 0.087 0.0820 0.133 0.111 70

95 0.0280 0.058 0.043 0.0550 0.115 0.079 0.0840 0.132 0.110 0.1120 0.151 0.133 95

120 0.0350 0.064 0.047 0.0710 0.124 0.090 0.1060 0.142 0.121 0.1400 0.209 0.156 120

150 0.0440 0.070 0.055 - - - 0.1320 0.157 0.140 0.1760 0.230 0.187 150

185 0.0530 0.094 0.061 - - - 0.1630 0.213 0.172 0.2170 0.251 0.217 185

240 0.0700 0.107 0.077 - - - 0.2110 0.247 0.210 0.2820 0.355 0.270 240

300 0.0870 0.117 0.090 - - - 0.2640 0.351 0.257 0.3530 0.398 0.326 300

400 0.1170 0.132 0.109 - - - - - - - - - 400

500 0.1460 0.145 0.124 - - - - - - - - - 500

630 0.1830 - - - - - - - - - - - 630

800 0.2330 - - - - - - - - - - - 800

1000 0.2910 - - - - - - - - - - - 1000

3 4

* DC CIRCUITS ONLY

PAGE 29

600/1000V STRANDED AL PVC PVC SWA PVC CABLES TO SANS 1507

RATED

AREA

mm2

NUMBER OF CORESRATED

AREA

mm2

1 2

Printed 2007/06/13

Page 33: AECMSA Electrical Cable Price Variation Factors

PAGE 30

SOLID

ALUMINIUMSTEEL PVC

SOLID

ALUMINIUMSTEEL PVC

SOLID

ALUMINIUMSTEEL PVC

16 0.009 0.036 0.037 0.013 0.039 0.039 0.017 0.057 0.050 16

25 0.014 0.039 0.032 0.021 0.045 0.043 0.028 0.070 0.055 25

35 0.019 0.042 0.035 0.030 0.067 0.051 0.039 0.076 0.062 35

50 0.028 0.066 0.049 0.042 0.077 0.064 0.056 0.111 0.076 50

70 0.039 0.072 0.055 0.058 0.110 0.074 0.078 0.127 0.096 70

95 0.053 0.104 0.068 0.080 0.127 0.096 0.107 0.144 0.120 95

120 - - - 0.100 0.134 0.108 0.134 0.157 0.131 120

150 - - - 0.126 0.149 0.125 0.168 0.219 0.163 150

185 - - - 0.156 0.209 0.154 0.207 0.238 0.195 185

240 - - - 0.202 0.233 0.190 0.269 0.342 0.248 240

300 - - - 0.252 0.254 0.217 0.336 0.376 0.292 300

PAGE 30

600/1000V SOLID AL PVC PVC SWA PVC CABLES TO SANS 1507

RATED

AREA

mm2

NUMBER OF CORESRATED

AREA

mm2

2 3 4

Printed 2007/06/13

Page 34: AECMSA Electrical Cable Price Variation Factors

PAGE 31

SOLID

ALUMINIUM

COPPER

ECCSTEEL PVC

SOLID

ALUMINIUM

COPPER

ECCSTEEL PVC

SOLID

ALUMINIUM

COPPER

ECCSTEEL PVC

16 0.009 0.011 0.026 0.037 0.013 0.011 0.029 0.039 0.017 0.012 0.047 0.050 16

25 0.014 0.011 0.024 0.032 0.021 0.011 0.031 0.043 0.028 0.012 0.053 0.055 25

35 0.019 0.011 0.028 0.035 0.030 0.012 0.050 0.051 0.039 0.012 0.060 0.062 35

50 0.028 0.019 0.042 0.049 0.042 0.019 0.053 0.064 0.056 0.018 0.086 0.076 50

70 0.039 0.030 0.041 0.055 0.058 0.032 0.074 0.074 0.078 0.032 0.089 0.096 70

95 0.053 0.041 0.062 0.068 0.080 0.041 0.079 0.096 0.107 0.041 0.099 0.120 95

120 - - - - 0.100 0.041 0.089 0.108 0.134 0.041 0.110 0.131 120

150 - - - - 0.126 0.059 0.086 0.125 0.168 0.065 0.148 0.163 150

185 - - - - 0.156 0.084 0.119 0.154 0.207 0.084 0.152 0.195 185

240 - - - - 0.202 0.084 0.144 0.190 0.269 0.085 0.240 0.248 240

300 - - - - 0.252 0.114 0.139 0.217 0.336 0.116 0.247 0.292 300

PAGE 31

600/1000V SOLAL PVC PVC SWA/ECC PVC CABLES TO SANS 1507

RATED

AREA

mm2

NUMBER OF CORESRATED

AREA

mm2

2 3 4

Printed 2007/06/13

Page 35: AECMSA Electrical Cable Price Variation Factors

PAGE 32

RATED

AREA

mm2

SOLID ALUMINIUMALIMINIUM STRIP

ARMOUR

SINGLE WIRE

ARMOURPVC WITH ASA PVC WITH SWA

RATED

AREA

mm2

280 (4X70) 0.078 0.025 0.110 0.067 0.070 280 (4X70)

380 (4X95) 0.107 0.039 0.125 0.084 0.090 380 (4X95)

480 (4X120) 0.134 0.043 0.137 0.098 0.105 480 (4X120)

600 (4X150) 0.168 0.047 0.148 0.108 0.110 600 (4X150)

740 (4X185) 0.207 0.051 0.205 0.124 0.129 740 (4X185)

960 (4X240) 0.269 0.074 0.230 0.149 0.159 960 (4X240)

1200 (4X300) 0.336 0.081 0.250 0.171 0.183 1200 (4X300)

600/1000V PVC PVCT ASA PVC or PVC PVC SWA PVC CABLES to BS 6346

PAGE 32

Printed 2007/06/13

Page 36: AECMSA Electrical Cable Price Variation Factors

PAGE 33

SOLID

ALUMINIUM

ALUMINIUM

STRIP ARMOURPVC

SOLID

ALUMINIUM

ALUMINIUM

STRIP ARMOURPVC

SOLID

ALUMINIUM

ALUMINIUM

STRIP ARMOURPVC

16 0.009 0.008 0.028 0.013 0.008 0.028 0.017 0.009 0.033 16

25 0.014 0.007 0.027 0.021 0.009 0.036 0.027 0.010 0.044 25

35 0.019 0.008 0.032 0.030 0.010 0.042 0.038 0.011 0.051 35

50 0.028 0.009 0.040 0.042 0.019 0.054 0.055 0.022 0.066 50

70 0.039 0.018 0.044 0.058 0.021 0.062 0.076 0.024 0.076 70

95 0.053 0.020 0.057 0.080 0.035 0.079 0.104 0.039 0.095 95

120 - - - 0.100 0.037 0.088 0.131 0.043 0.109 120

150 - - - 0.126 0.041 0.107 0.164 0.049 0.129 150

185 - - - 0.156 0.045 0.126 0.202 0.071 0.154 185

240 - - - 0.202 0.067 0.149 0.262 0.078 0.187 240

300 - - - 0.252 0.074 0.177 0.328 0.084 0.222 300

PAGE 33

600/1000V PVC PVCT ASA PVC CABLES to BS 6346

RATED

AREA

mm2

NUMBER OF CORESRATED

AREA

mm2

2 3 4

Printed 2007/06/13

Page 37: AECMSA Electrical Cable Price Variation Factors

PAGE 34

RATED AREA mm2 COPPER PVC RATED AREA mm2

4 0.012 0.011 4

6 0.018 0.015 6

10 0.030 0.018 10

16 0.045 0.021 16

25 0.064 0.028 25

600/1000V 3 CORE PVC PVC CABLES WITH SPLIT-CONCENTRIC NEUTRAL &

EARTH CONDUCTORS TO SANS 1507

PAGE 34

Printed 2007/06/13

Page 38: AECMSA Electrical Cable Price Variation Factors

PAGE 35

mm2 Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape° mm

2

50 0.0513 0.0200 1.60 mm 0.0242 0.0402 0.0376 0.0067 50

70 0.0717 0.0224 1.60 mm 0.0259 0.0429 0.0452 0.0073 70

95 0.0973 0.0250 1.60 mm 0.0277 0.0474 0.0545 0.0080 95

120 0.1214 0.0271 1.60 mm 0.0291 0.0498 0.0630 0.0085 120

150 0.1484 0.0295 1.60 mm 0.0308 0.0544 0.0722 0.0091 150

185 0.1840 0.0319 2.0 mm 0.0418 0.0541 0.0942 0.0097 185

240 0.2397 0.0363 2.0 mm 0.0446 0.0649 0.1129 0.0106 240

300 0.2990 0.0422 2.0 mm 0.0486 0.0681 0.1345 0.0116 300

400 0.3813 0.0495 2.0 mm 0.0528 0.0823 0.1628 0.0129 400

500 0.4869 0.0568 2.5 mm 0.0728 0.0982 0.2142 0.0141 500

630 0.6425 0.0626 2.5 mm 0.0785 0.1107 0.2611 0.0154 630

800 0.8290 0.0692 2.5 mm 0.0848 0.1238 0.3242 0.0168 800

1000 1.0380 0.0762 2.5 mm 0.0917 0.1427 0.3934 0.0182 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor including aluminium wire armour

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

3.8/6.6kV SINGLE CORE TYPE A CABLE TO SANS 1339

PAGE 35

Printed 2007/06/13

Page 39: AECMSA Electrical Cable Price Variation Factors

PAGE 36

mm2 Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape° mm

2

50 0.0520 0.0261 1.6000 0.0263 0.0436 0.0397 0.0075 50

70 0.0724 0.0290 1.6000 0.0280 0.0479 0.0473 0.0081 70

95 0.0980 0.0321 1.6000 0.0298 0.0509 0.0566 0.0087 95

120 0.1222 0.0346 2.0000 0.0313 0.0551 0.0651 0.0092 120

150 0.1492 0.0376 2.0000 0.0417 0.0639 0.0831 0.0098 150

185 0.1847 0.0405 2.0000 0.0438 0.0638 0.0962 0.0104 185

240 0.2404 0.0447 2.0000 0.0469 0.0713 0.1152 0.0112 240

300 0.2995 0.0487 2.0000 0.0498 0.0755 0.1357 0.0121 300

400 0.3816 0.0546 2.5000 0.0540 0.0866 0.1640 0.0132 400

500 0.4871 0.0599 2.5000 0.0734 0.0990 0.2149 0.0143 500

630 0.6426 0.0659 2.5000 0.0794 0.1118 0.2620 0.0155 630

800 0.8292 0.0728 2.5000 0.0856 0.1233 0.3250 0.0169 800

1000 1.0382 0.0802 2.5000 0.0926 0.1440 0.3942 0.0184 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor including aluminium wire armour

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

6.35/11kV SINGLE CORE TYPE A CABLE TO SANS 1339

PAGE 36

Printed 2007/06/13

Page 40: AECMSA Electrical Cable Price Variation Factors

PAGE 37

mm2 Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape° mm

2

50 0.0529 0.0341 1.60 0.0288 0.0493 0.0422 0.0084 50

70 0.0733 0.0377 1.60 0.0305 0.0521 0.0499 0.0090 70

95 0.0989 0.0414 2.00 0.0409 0.0578 0.0678 0.0096 95

120 0.1231 0.0445 2.00 0.0428 0.0634 0.0766 0.0101 120

150 0.1501 0.0481 2.00 0.0449 0.0663 0.0862 0.0107 150

185 0.1856 0.0516 2.00 0.0470 0.0715 0.0994 0.0113 185

240 0.2413 0.0567 2.00 0.0500 0.0782 0.1183 0.0121 240

300 0.3004 0.0615 2.00 0.0529 0.0825 0.1388 0.0129 300

400 0.3825 0.0686 2.50 0.0728 0.0982 0.1828 0.0141 400

500 0.4880 0.0750 2.50 0.0776 0.1072 0.2190 0.0152 500

630 0.6435 0.0823 2.50 0.0833 0.1202 0.2659 0.0164 630

800 0.8301 0.0907 2.50 0.0899 0.1367 0.3293 0.0178 800

1000 1.0391 0.0995 2.50 0.0969 0.1567 0.3985 0.0193 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor including aluminium wire armour

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

8.7/15kV SINGLE CORE TYPE A CABLE TO SANS 1339 AFAA

PAGE 37

Printed 2007/06/13

Page 41: AECMSA Electrical Cable Price Variation Factors

PAGE 38

mm2 Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape° mm

2

50 0.0537 0.0424 1.60 0.0312 0.0549 0.0446 0.0092 50

70 0.0741 0.0465 2.00 0.0416 0.0587 0.0609 0.0098 70

95 0.0997 0.0508 2.00 0.0438 0.0648 0.0707 0.0104 95

120 0.1239 0.0544 2.00 0.0457 0.0674 0.0796 0.0109 120

150 0.1509 0.0585 2.00 0.0478 0.0726 0.0891 0.0115 150

185 0.1864 0.0626 2.00 0.0499 0.0757 0.1023 0.0121 185

240 0.2421 0.0685 2.00 0.0529 0.0825 0.1212 0.0129 240

300 0.3012 0.0741 2.50 0.0711 0.0921 0.1570 0.0138 300

400 0.3833 0.0823 2.50 0.0764 0.1028 0.1864 0.0149 400

500 0.4888 0.0897 2.50 0.0815 0.1147 0.2230 0.0160 500

630 0.6443 0.0982 2.50 0.0870 0.1284 0.2696 0.0172 630

800 0.8309 0.1079 2.50 0.0936 0.1454 0.3329 0.0186 800

1000 1.0399 0.1181 2.50 0.1005 0.1623 0.4021 0.0201 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor including aluminium wire armour

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

12.7/22kV SINGLE CORE TYPE A CABLE TO SANS 1339

PAGE 38

Printed 2007/06/13

Page 42: AECMSA Electrical Cable Price Variation Factors

PAGE 39

mm2 Copper* XLPE AWA Diameter AWA PVC Aluminium# Copper Tape° mm

2

50 0.0558 0.0663 2.00 0.0467 0.0711 0.0601 0.0112 50

70 0.0761 0.0718 2.00 0.0488 0.0742 0.0682 0.0118 70

95 0.1017 0.0776 2.00 0.0511 0.0798 0.0779 0.0124 95

120 0.1259 0.0824 2.00 0.0529 0.0825 0.0868 0.0129 120

150 0.1529 0.0879 2.50 0.0701 0.0908 0.1115 0.0135 150

185 0.1885 0.0934 2.50 0.0728 0.0982 0.1251 0.0141 185

240 0.2441 0.1013 2.50 0.0766 0.1030 0.1449 0.0150 240

300 0.3032 0.1088 2.50 0.0805 0.1133 0.1664 0.0158 300

400 0.3854 0.1198 2.50 0.0858 0.1236 0.1958 0.0170 400

500 0.4908 0.1298 2.50 0.0909 0.1382 0.2324 0.0181 500

630 0.6464 0.1411 2.50 0.0964 0.1496 0.2790 0.0193 630

800 0.8329 0.1542 3.15 0.1311 0.1722 0.3704 0.0207 800

1000 1.0420 0.1679 3.15 0.1398 0.1923 0.4414 0.0222 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor including aluminium wire armour

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

19/33kV SINGLE CORE TYPE A CABLE TO SANS 1339

PAGE 39

Printed 2007/06/13

Page 43: AECMSA Electrical Cable Price Variation Factors

PAGE 40

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0580 0.0200 0.0174 0.0134 0.0135 50

70 0.0790 0.0224 0.0200 0.0194 0.0146 70

95 0.1052 0.0250 0.0216 0.0268 0.0159 95

120 0.1299 0.0271 0.0243 0.0339 0.0169 120

150 0.1575 0.0295 0.0258 0.0414 0.0181 150

185 0.1937 0.0319 0.0290 0.0524 0.0193 185

240 0.2503 0.0363 0.0314 0.0683 0.0212 240

300 0.3106 0.0422 0.0360 0.0859 0.0232 300

400 0.3942 0.0495 0.0440 0.1100 0.0258 400

500 0.5010 0.0568 0.0502 0.1415 0.0283 500

630 0.6578 0.0626 0.0566 0.1826 0.0307 630

800 0.8458 0.0692 0.0641 0.2394 0.0335 800

1000 1.0563 0.0762 0.0723 0.3016 0.0365 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

3.8/6.6kV SINGLE CORE TYPE A2 CABLE TO SANS 1339 AFAA

PAGE 40

Printed 2007/06/13

Page 44: AECMSA Electrical Cable Price Variation Factors

PAGE 41

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0595 0.0261 0.0204 0.0134 0.0149 50

70 0.0805 0.0290 0.0218 0.0194 0.0161 70

95 0.1067 0.0321 0.0248 0.0268 0.0174 95

120 0.1314 0.0346 0.0261 0.0339 0.0184 120

150 0.1590 0.0376 0.0293 0.0414 0.0196 150

185 0.1951 0.0405 0.0309 0.0524 0.0208 185

240 0.2516 0.0447 0.0351 0.0683 0.0225 240

300 0.3115 0.0487 0.0393 0.0859 0.0241 300

400 0.3949 0.0546 0.0450 0.1100 0.0265 400

500 0.5014 0.0599 0.0506 0.1415 0.0286 500

630 0.6582 0.0659 0.0572 0.1826 0.0311 630

800 0.8461 0.0728 0.0647 0.2394 0.0339 800

1000 1.0567 0.0802 0.0729 0.3016 0.0368 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

6,35/11kV single core type A2 cable to SANS 1339 AFAA

PAGE 41

Printed 2007/06/13

Page 45: AECMSA Electrical Cable Price Variation Factors

PAGE 42

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0613 0.0341 0.0225 0.0134 0.0167 50

70 0.0823 0.0377 0.0255 0.0194 0.0179 70

95 0.1085 0.0414 0.0288 0.0268 0.0192 95

120 0.1332 0.0445 0.0301 0.0339 0.0202 120

150 0.1608 0.0481 0.0335 0.0414 0.0214 150

185 0.1969 0.0516 0.0352 0.0524 0.0226 185

240 0.2534 0.0567 0.0396 0.0683 0.0243 240

300 0.3133 0.0615 0.0441 0.0859 0.0259 300

400 0.3967 0.0686 0.0502 0.1100 0.0283 400

500 0.5032 0.0750 0.0561 0.1415 0.0304 500

630 0.6600 0.0823 0.0629 0.1826 0.0328 630

800 0.8479 0.0907 0.0707 0.2394 0.0357 800

1000 1.0584 0.0995 0.0792 0.3016 0.0386 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

8,7/15kV single core type A2 cable to SANS 1339 AFAA

PAGE 42

Printed 2007/06/13

Page 46: AECMSA Electrical Cable Price Variation Factors

PAGE 43

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0629 0.0424 0.0261 0.0134 0.0183 50

70 0.0839 0.0465 0.0292 0.0194 0.0195 70

95 0.1101 0.0508 0.0309 0.0268 0.0208 95

120 0.1348 0.0544 0.0341 0.0339 0.0218 120

150 0.1624 0.0585 0.0358 0.0414 0.0230 150

185 0.1985 0.0626 0.0394 0.0524 0.0242 185

240 0.2550 0.0685 0.0441 0.0683 0.0259 240

300 0.3150 0.0741 0.0466 0.0859 0.0275 300

400 0.3983 0.0823 0.0528 0.1100 0.0299 400

500 0.5048 0.0897 0.0589 0.1415 0.0320 500

630 0.6616 0.0982 0.0657 0.1826 0.0345 630

800 0.8495 0.1079 0.0766 0.2394 0.0373 800

1000 1.0601 0.1181 0.0856 0.3016 0.0402 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

12,7/22kV single core type A2 cable to SANS 1339 AFAA

PAGE 43

Printed 2007/06/13

Page 47: AECMSA Electrical Cable Price Variation Factors

PAGE 44

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0670 0.0663 0.0350 0.0134 0.0224 50

70 0.0879 0.0718 0.0366 0.0194 0.0236 70

95 0.1142 0.0776 0.0404 0.0268 0.0249 95

120 0.1389 0.0824 0.0420 0.0339 0.0259 120

150 0.1664 0.0879 0.0459 0.0414 0.0271 150

185 0.2026 0.0934 0.0478 0.0524 0.0283 185

240 0.2591 0.1013 0.0529 0.0683 0.0300 240

300 0.3190 0.1088 0.0581 0.0859 0.0316 300

400 0.4023 0.1198 0.0648 0.1100 0.0340 400

500 0.5089 0.1298 0.0715 0.1415 0.0361 500

630 0.6657 0.1411 0.0790 0.1826 0.0385 630

800 0.8536 0.1542 0.0878 0.2394 0.0414 800

1000 1.0641 0.1679 0.1007 0.3016 0.0443 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

19/33kV single core type A2 cable to SANS 1339 AFAA

PAGE 44

Printed 2007/06/13

Page 48: AECMSA Electrical Cable Price Variation Factors

PAGE 45

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0647 0.0200 0.0176 0.0134 0.0202 50

70 0.0863 0.0224 0.0202 0.0194 0.0220 70

95 0.1132 0.0250 0.0216 0.0268 0.0239 95

120 0.1384 0.0271 0.0243 0.0339 0.0254 120

150 0.1575 0.0295 0.0258 0.0414 0.0181 150

185 0.1937 0.0319 0.0290 0.0524 0.0193 185

240 0.2503 0.0363 0.0314 0.0683 0.0212 240

300 0.3106 0.0422 0.0360 0.0859 0.0232 300

400 0.3942 0.0495 0.0440 0.1100 0.0258 400

500 0.5010 0.0568 0.0502 0.1415 0.0283 500

630 0.6578 0.0626 0.0566 0.1826 0.0307 630

800 0.8458 0.0692 0.0641 0.2394 0.0335 800

1000 1.0563 0.0762 0.0723 0.3016 0.0365 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

3,8/6,6kV single core type B cables to SANS 1339

PAGE 45

Printed 2007/06/13

Page 49: AECMSA Electrical Cable Price Variation Factors

PAGE 46

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0670 0.0261 0.0207 0.0134 0.0224 50

70 0.0885 0.0290 0.0221 0.0194 0.0242 70

95 0.1154 0.0321 0.0251 0.0268 0.0261 95

120 0.1406 0.0346 0.0264 0.0339 0.0276 120

150 0.1688 0.0376 0.0296 0.0414 0.0294 150

185 0.2055 0.0405 0.0312 0.0524 0.0312 185

240 0.2629 0.0447 0.0354 0.0683 0.0337 240

300 0.3115 0.0487 0.0393 0.0859 0.0241 300

400 0.3949 0.0546 0.0450 0.1100 0.0265 400

500 0.5014 0.0599 0.0506 0.1415 0.0286 500

630 0.6582 0.0659 0.0572 0.1826 0.0311 630

800 0.8461 0.0728 0.0647 0.2394 0.0339 800

1000 1.0567 0.0802 0.0729 0.3016 0.0368 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

6,35/11kV single core type B cable to SANS 1339

PAGE 46

Printed 2007/06/13

Page 50: AECMSA Electrical Cable Price Variation Factors

PAGE 47

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0696 0.0341 0.0228 0.0134 0.0251 50

70 0.0912 0.0377 0.0258 0.0194 0.0269 70

95 0.1181 0.0414 0.0290 0.0268 0.0287 95

120 0.1433 0.0445 0.0304 0.0339 0.0303 120

150 0.1608 0.0481 0.0335 0.0414 0.0214 150

185 0.1969 0.0516 0.0352 0.0524 0.0226 185

240 0.2534 0.0567 0.0396 0.0683 0.0243 240

300 0.3133 0.0615 0.0441 0.0859 0.0259 300

400 0.3967 0.0686 0.0502 0.1100 0.0283 400

500 0.5032 0.0750 0.0561 0.1415 0.0304 500

630 0.6600 0.0823 0.0629 0.1826 0.0328 630

800 0.8479 0.0907 0.0707 0.2394 0.0357 800

1000 1.0584 0.0995 0.0792 0.3016 0.0386 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

8,7/15kV single core type B cable to SANS 1339

PAGE 47

Printed 2007/06/13

Page 51: AECMSA Electrical Cable Price Variation Factors

PAGE 48

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0721 0.0424 0.0264 0.0134 0.0275 50

70 0.0936 0.0465 0.0295 0.0194 0.0293 70

95 0.1205 0.0508 0.0312 0.0268 0.0312 95

120 0.1457 0.0544 0.0344 0.0339 0.0327 120

150 0.1739 0.0585 0.0361 0.0414 0.0345 150

185 0.1985 0.0626 0.0394 0.0524 0.0242 185

240 0.2550 0.0685 0.0441 0.0683 0.0259 240

300 0.3150 0.0741 0.0466 0.0859 0.0275 300

400 0.3983 0.0823 0.0528 0.1100 0.0299 400

500 0.5048 0.0897 0.0589 0.1415 0.0320 500

630 0.6616 0.0982 0.0657 0.1826 0.0345 630

800 0.8495 0.1079 0.0766 0.2394 0.0373 800

1000 1.0601 0.1181 0.0856 0.3016 0.0402 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

12,7/22kV single core type B cable to SANS 1339

PAGE 48

Printed 2007/06/13

Page 52: AECMSA Electrical Cable Price Variation Factors

PAGE 49

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.0726 0.0663 0.0350 0.0134 0.0280 50

70 0.0879 0.0718 0.0366 0.0194 0.0236 70

95 0.1142 0.0776 0.0404 0.0268 0.0249 95

120 0.1389 0.0824 0.0420 0.0339 0.0259 120

150 0.1664 0.0879 0.0459 0.0414 0.0271 150

185 0.2026 0.0934 0.0478 0.0524 0.0283 185

240 0.2591 0.1013 0.0529 0.0683 0.0300 240

300 0.3190 0.1088 0.0581 0.0859 0.0316 300

400 0.4023 0.1198 0.0648 0.1100 0.0340 400

500 0.5089 0.1298 0.0715 0.1415 0.0361 500

630 0.6657 0.1411 0.0790 0.1826 0.0385 630

800 0.8536 0.1542 0.0878 0.2394 0.0414 800

1000 1.0641 0.1679 0.1007 0.3016 0.0443 1000

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

19/33kV single core type B cable to SANS 1339

PAGE 49

Printed 2007/06/13

Page 53: AECMSA Electrical Cable Price Variation Factors

PAGE 50

mm2 Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape° mm

2

16 0.0614 0.0433 2.0 0.1388 0.0740 16

25 0.0885 0.0487 2.0 0.1488 0.0791 0.0215 0.0174 25

35 0.1175 0.0537 2.0 0.1576 0.0864 0.0298 0.0186 35

50 0.1541 0.0600 2.5 0.2152 0.1029 0.0404 0.0202 50

70 0.2154 0.0673 2.5 0.2315 0.1137 0.0582 0.0220 70

95 0.2924 0.0750 2.5 0.2502 0.1281 0.0806 0.0239 95

120 0.3650 0.0813 2.5 0.2660 0.1414 0.1019 0.0254 120

150 0.4462 0.0886 2.5 0.2823 0.1550 0.1243 0.0272 150

185 0.5530 0.0958 3.15 0.3820 0.1733 0.1574 0.0290 185

240 0.7204 0.1089 3.15 0.4164 0.2014 0.2054 0.0317 240

300 0.8988 0.1265 3.15 0.4521 0.2372 0.2583 0.0347 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

3.8/6.6kV THREE-CORE TYPE A CABLE TO SANS 1339

PAGE 50

Printed 2007/06/13

Page 54: AECMSA Electrical Cable Price Variation Factors

PAGE 51

mm2 Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape° mm

2

16 0.0636 0.0579 2.0 0.1553 0.0849 50

25 0.0907 0.0644 2.5 0.2099 0.0965 0.0215 0.0196 70

35 0.1198 0.0705 2.5 0.2210 0.1045 0.0298 0.0209 95

50 0.1563 0.0782 2.5 0.2368 0.1181 0.0404 0.0224 120

70 0.2176 0.0869 2.5 0.2531 0.1295 0.0582 0.0242 150

95 0.2946 0.0962 2.5 0.2718 0.1460 0.0806 0.0261 185

120 0.3672 0.1039 2.5 0.2876 0.1642 0.1019 0.0276 240

150 0.4484 0.1127 3.15 0.3868 0.1812 0.1243 0.0294 300

185 0.5552 0.1215 3.15 0.4092 0.1965 0.1574 0.0312 400

240 0.7224 0.1341 3.15 0.4406 0.2270 0.2054 0.0337 500

300 0.9002 0.1462 3.15 0.4708 0.2550 0.2583 0.0362 630

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

6.35/11kV THREE-CORE TYPE A CABLE TO SANS 1339

PAGE 51

Printed 2007/06/13

Page 55: AECMSA Electrical Cable Price Variation Factors

PAGE 52

mm2 Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape° mm

2

25 0.0934 0.0858 2.5 0.2358 0.1176 0.0215 0.0223 25

35 0.1224 0.0931 2.5 0.2473 0.1263 0.0298 0.0235 35

50 0.1589 0.1024 2.5 0.2627 0.1413 0.0404 0.0251 50

70 0.2202 0.1130 2.5 0.2804 0.1567 0.0582 0.0269 70

95 0.2973 0.1243 3.15 0.3808 0.1757 0.0806 0.0287 95

120 0.3699 0.1336 3.15 0.3989 0.1877 0.1019 0.0303 120

150 0.4511 0.1442 3.15 0.4213 0.2070 0.1243 0.0321 150

185 0.5579 0.1548 3.15 0.4436 0.2320 0.1574 0.0338 185

240 0.7251 0.1700 3.55 0.5380 0.2625 0.2054 0.0364 240

300 0.9029 0.1846 3.55 0.5714 0.2897 0.2583 0.0388 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

8.7/15kV THREE-CORE TYPE A CABLE TO SANS 1339 AFAA

PAGE 52

Printed 2007/06/13

Page 56: AECMSA Electrical Cable Price Variation Factors

PAGE 53

mm2 Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape° mm

2

35 0.1249 0.1163 2.5 0.2713 0.1441 0.0298 0.0260 35

50 0.1614 0.1271 2.5 0.2857 0.1568 0.0404 0.0275 50

70 0.2227 0.1394 3.15 0.3862 0.1766 0.0582 0.0293 70

95 0.2997 0.1524 3.15 0.4098 0.1983 0.0806 0.0312 95

120 0.3723 0.1632 3.15 0.4279 0.2110 0.1019 0.0327 120

150 0.4535 0.1754 3.15 0.4502 0.2296 0.1243 0.0345 150

185 0.5603 0.1877 3.15 0.4720 0.2556 0.1574 0.0363 185

240 0.7275 0.2054 3.55 0.5700 0.2851 0.2054 0.0388 240

300 0.9054 0.2223 3.55 0.6027 0.3087 0.2583 0.0413 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

12.7/22kV THREE-CORE TYPE A CABLE TO SANS 1339

PAGE 53

Printed 2007/06/13

Page 57: AECMSA Electrical Cable Price Variation Factors

PAGE 54

mm2 Copper* XLPE SWA Diameter SWA PVC Aluminium# Copper Tape° mm

2

50 0.1675 0.1988 3.15 0.4394 0.1934 0.0404 0.0336 50

70 0.2288 0.2153 3.15 0.4605 0.2415 0.0582 0.0354 70

95 0.3058 0.2328 3.55 0.5483 0.2636 0.0806 0.0373 95

120 0.3784 0.2472 3.55 0.5700 0.2851 0.1019 0.0388 120

150 0.4596 0.2637 3.55 0.5939 0.2992 0.1243 0.0406 150

185 0.5664 0.2802 3.55 0.6184 0.3235 0.1574 0.0424 185

240 0.7337 0.3039 3.55 0.6538 0.3601 0.2054 0.0449 240

300 0.9114 0.3265 3.55 0.6878 0.3974 0.2583 0.0474 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

19/33kV THREE-CORE TYPE A CABLE TO SANS 1339

PAGE 54

Printed 2007/06/13

Page 58: AECMSA Electrical Cable Price Variation Factors

PAGE 55

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

16 0.0775 0.0433 0.0395 16

25 0.1059 0.0487 0.0445 0.0215 0.0322 25

35 0.1362 0.0537 0.0496 0.0298 0.0348 35

50 0.1743 0.0600 0.0557 0.0404 0.0373 50

70 0.2373 0.0673 0.0640 0.0582 0.0404 70

95 0.2924 0.0750 0.0710 0.0806 0.0439 95

120 0.3650 0.0813 0.0782 0.1019 0.0239 120

150 0.4461 0.0886 0.0878 0.1243 0.0254 150

185 0.5530 0.0958 0.0966 0.1574 0.0272 185

240 0.7204 0.1089 0.1124 0.2054 0.0290 240

300 0.8988 0.1265 0.1320 0.2583 0.0317 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

3.8/6.6kV THREE-CORE TYPE B CABLE TO SANS 1339

PAGE 55

Printed 2007/06/13

Page 59: AECMSA Electrical Cable Price Variation Factors

PAGE 56

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

16 0.0819 0.0579 0.0487 16

25 0.1103 0.0644 0.0520 0.0215 0.0366 25

35 0.1406 0.0705 0.0585 0.0298 0.0393 35

50 0.1787 0.0782 0.0639 0.0404 0.0417 50

70 0.2418 0.0869 0.0727 0.0582 0.0448 70

95 0.2946 0.0962 0.0844 0.0806 0.0484 95

120 0.3672 0.1039 0.0908 0.1019 0.0261 120

150 0.4483 0.1127 0.1012 0.1243 0.0276 150

185 0.5552 0.1215 0.1106 0.1574 0.0294 185

240 0.7224 0.1341 0.1247 0.2054 0.0312 240

300 0.9002 0.1462 0.1394 0.2583 0.0337 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

6.35/11kV THREE-CORE TYPE B CABLE TO SANS 1339

PAGE 56

Printed 2007/06/13

Page 60: AECMSA Electrical Cable Price Variation Factors

PAGE 57

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

25 0.0934 0.0858 0.0640 0.0215 0.0223 25

35 0.1224 0.0931 0.0700 0.0298 0.0235 35

50 0.1589 0.1024 0.0785 0.0404 0.0251 50

70 0.2202 0.1130 0.0854 0.0582 0.0269 70

95 0.2973 0.1243 0.0943 0.0806 0.0287 95

120 0.3699 0.1336 0.1042 0.1019 0.0303 120

150 0.4510 0.1442 0.1135 0.1243 0.0321 150

185 0.5579 0.1548 0.1233 0.1574 0.0338 185

240 0.7251 0.1700 0.1403 0.2054 0.0364 240

300 0.9029 0.1846 0.1600 0.2583 0.0388 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

8.7/15kV THREE-CORE TYPE B CABLE TO SANS 1339 AFAA

PAGE 57

Printed 2007/06/13

Page 61: AECMSA Electrical Cable Price Variation Factors

PAGE 58

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

35 0.1249 0.1163 0.0857 0.0298 0.0260 35

50 0.1614 0.1271 0.0952 0.0404 0.0275 50

70 0.2227 0.1394 0.1042 0.0582 0.0293 70

95 0.2997 0.1524 0.1141 0.0806 0.0312 95

120 0.3723 0.1632 0.1249 0.1019 0.0327 120

150 0.4534 0.1754 0.1392 0.1243 0.0345 150

185 0.5603 0.1877 0.1500 0.1574 0.0363 185

240 0.7275 0.2054 0.1709 0.2054 0.0388 240

300 0.9053 0.2223 0.1835 0.2583 0.0413 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

12.7/22kV THREE-CORE TYPE B CABLE TO SANS 1339

PAGE 58

Printed 2007/06/13

Page 62: AECMSA Electrical Cable Price Variation Factors

PAGE 59

mm2 Copper* XLPE PVC Aluminium# Copper Tape° mm

2

50 0.1675 0.1988 0.1302 0.0404 0.0336 50

70 0.2288 0.2153 0.1426 0.0582 0.0354 70

95 0.3058 0.2328 0.1540 0.0806 0.0373 95

120 0.3784 0.2472 0.1709 0.1019 0.0388 120

150 0.4595 0.2637 0.1807 0.1243 0.0406 150

185 0.5664 0.2802 0.1952 0.1574 0.0424 185

240 0.7337 0.3039 0.2165 0.2054 0.0449 240

300 0.9114 0.3265 0.2381 0.2583 0.0474 300

*variation factor applies to a copper conductor including copper tape screen

#variation factor applies to an aluminium conductor

°variation factor for a copper tape screen applied to a cable with an aluminium conductor

19/33kV THREE-CORE TYPE B CABLE TO SANS 1339

PAGE 59

Printed 2007/06/13

Page 63: AECMSA Electrical Cable Price Variation Factors

PAGE 60

SIZE

CORES 2 3 4 6 9 12 16 21 27 37 52 61COPPER 0.0013 0.0020 0.0025 0.0038 0.0054 0.0077 0.010 0.014 0.017 0.024 0.034 0.039PVC 0.0150 0.0160 0.0170 0.0210 0.0270 0.0320 0.039 0.046 0.054 0.075 0.098 0.110SWA 0.0150 0.0160 0.0170 0.0200 0.0330 0.0350 0.038 0.029* 0.033* 0.037* 0.043* 0.044*

SIZE

CORES 2 3 4 6 9 10 16 21 27 37 52 61COPPER 0.0030 0.0045 0.006 0.009 0.014 0.018 0.024 0.032 0.041 0.056 0.079 0.093PVC 0.017 0.0190 0.021 0.025 0.033 0.039 0.046 0.061 0.075 0.094 0.129 0.149SWA 0.017 0.0180 0.019 0.023 0.034 0.017 0.025* 0.033* 0.037* 0.041* 0.048* 0.052*

SIZE

CORES 2 3 4 6 9 12 16 21 27 37 52 61COPPER 0.004 0.006 0.008 0.012 0.017 0.024 0.032 0.042 0.053 0.073 0.102 0.121PVC 0.019 0.021 0.025 0.030 0.040 0.045 0.059 0.074 0.087 0.113 0.160 0.175SWA 0.018 0.019 0.021 0.034 0.018* 0.029* 0.033* 0.037* 0.041* 0.045* 0.054* 0.058*

SIZE SIZECORES 2 3 4 37 CORES 2 3 4 6 9 12 21COPPER 0.0051 0.0078 0.010 0.094 COPPER 0.008 0.012 0.016 0.023 0.035 0.047 0.083PVC 0.0230 0.0250 0.028 0.123 PVC 0.026 0.028 0.032 0.037 0.057 0.066 0.096SWA 0.0210 0.0220 0.024 - SWA 0.023 0.024 0.035 0.020 0.026 0.030 0.036*

SIZE SIZECORES 2 3 4 6 CORES 2 4 12 2 3 4 6COPPER 0.012 0.018 0.024 0.035 COPPER 0.020 0.040 0.120 0.031 0.048 0.062 0.073PVC 0.032 0.036 0.038 0.049 PVC 0.036 0.041 0.090 0.043 0.051 0.058 0.073SWA 0.032 0.035 0.038 0.030 SWA 0.039 0.023* 0.043* 0.028* 0.031* 0.033* 0.037*

*Galvanised Ferrous Tape

PAGE 60

1,6mm2

2,5mm2 4mm2

6mm2 10mm2 16mm2

STANDARD SIGNALLING CABLES (OUTDOOR) TO SATS SPECIFICATION NO CSE 49E

0,9mm2

1,4mm2

Printed 2007/06/13

Page 64: AECMSA Electrical Cable Price Variation Factors

PAGE 61

SIZE CORES COPPER PVC

0,5mm2 50 0.0110 0.0210

70 0.0140 0.0250

0,63mm2 12 0.0030 0.0100

20 0.0060 0.0120

60 0.0170 0.0210

68 0.0210 0.0300

80 0.0230 0.0330

0,9mm2 1 0.0010 0.0009

4 0.0025 0.0120

10 0.0060 0.0150

20 0.0120 0.0180

16mm2 1 0.0150 0.0100

12 0.1800 0.0750

35mm2 1 0.0320 0.0210

2 0.0650 0.0510

3 0.0980 0.0530

6 0.1980 0.1140

12 0.3960 0.1730

70mm2 2 0.1310 0.0590

3 0.1960 0.0710

STANDARD SIGNALLING CABLES (INDOOR) TO SATS SPECIFICATION NO CSE 49G

PAGE 61

Printed 2007/06/13