Perma-Column® combines the durability of concrete with the value of post-frame construction for a long-lasting foundation performance.

Build better, build stronger, build to last.

Perma-Column® is 3x stronger than standard concrete

Supports solid posts, nail-laminated or glue-laminated wood columns

10,000 psi precast concrete

60,000 psi rebar

Powder-coated ¼” steel bracket

Uplift anchors and 12” and 24” column extenders available

Guaranteed to last generations

The International Code Council has evaluated and certified Perma-Column® precast concrete posts are compliant with the following:

• 2018 and 2015 International Building Code® (IBC)• 2018 and 2015 International Residential Code® (IRC)• 2017 Florida Building Code—Building• 2017 Florida Building Code—Residential• 2016 California Building Code (CBC)• 2016 California Residential Code (CRC)

• Easier permitting and approvals• Assured code-compliance

• Trust in Perma-Column® quality• Confidence in their lasting investment See ICC-ES Evaluation Report No. ESR-4238 at icc-es.org/report-listing/esr-4238/

Builder advantages

Customer benefits

CERTIFIED EXCELLENCEICC-ES certified

The Perma-Column® difference

LOAD AND RESISTANCE FACTOR DESIGN (LRFD)

PLRFD (lb)

PC6300 PC6400 PC6600 PC8300 PC8400 PC8500

VLRFD-x

(lb)VLRFD-z

(lb)VLRFD-x

(lb)VLRFD-z

(lb)VLRFD-x

(lb)VLRFD-z

(lb)VLRFD-x

(lb)VLRFD-z

(lb)VLRFD-x

(lb)VLRFD-z

(lb)VLRFD-x

(lb)VLRFD-z

(lb)

1000090008000

372236683614

370636523598

461045554501

497749184860

431442604205

455644984441

512150635004

464045874534

638663276269

630562476190

759275337475

787878177756

700060005000

355935053451

354434903436

444743924338

480147424684

415140974042

438443264269

494648874828

448144284375

621061516093

613260746016

741673577299

769576347573

400030002000

339733423288

338233283274

428442294175

462545664507

398839343879

421241544097

477047114653

432142684215

603459765917

595859005843

724071817123

751374527391

10000

-1000-2000

3234318029632746

3220316629502734

4120406638493631

4449439041553921

3825377135533336

4039398237533523

4594453543014067

4162410938973684

5858580055665331

5785572754955264

7064700567716536

7330726970266782

-3000-4000-5000

252823112094

251823022086

341431962979

368634513216

311929012684

329430642835

383235983363

347232603047

509748624628

503348014570

630160675832

653962956051

BUILD BETTER. BUILD STRONGER. BUILD TO LAST.

SHEAR CAPACITIES

LOAD AND RESISTANCE FACTOR DESIGN (LRFD) ALLOWABLE STRENGTH DESIGN (ASD)

Model ID

Width (in)

Depth (in)

Length (in)

PLRFD (lb)

MLRFD-x

(ft-lb)MLRFD-z (ft-lb)

TLRFD (lb)

PASD (lb)

MASD-x (ft-lb)

MASD-z (ft-lb)

TASD (lb)

PC6300 5-3/8 5-3/8 59-3/4 113100 6517 6620 10320 70700 4073 4137 6870

PC6400 6-7/8 5-3/8 59-3/4 140100 9217 6723 9070 87600 5761 4202 6030

PC6600 6-3/8 5-3/8 59-3/4 131100 8317 6694 9360 82000 5198 4184 6230

PC8300 5-3/8 7-1/8 59-3/4 153100 9781 14545 15710 95700 6113 9091 10450

PC8400 6-7/8 7-1/8 59-3/4 188900 13966 14792 13590 118100 8729 9245 9040

PC8500 8-3/8 7-1/8 59-3/4 223000 17955 14945 12340 139400 11222 9341 8210

Perma-Column® meets the market demand for durability, fits into your current building process, and elevates your reputation for enduring quality.

For SI: 1 inch = 25.4 mm, 1 pound = 4.4482 N 1 For biaxial bending: mx + mz < 1 Mx Mz 2 The tabulated values account for combined axial compression load and bending moment load. No reduction in

axial compression loads and bending moment loads for combined axial compression bending moment is required. 3 For combined tension loads and bending moment loads: t + m < 1 T M4 Length is measured from the top of the concrete to the bottom of the concrete.

For SI: 1 inch = 25.4 mm, 1 pound = 4.4482 N 1 The tabulated shear values are for columns with axial tension load (ACI 318-14 Eq. 22.5.6.1 and 22.5.7.1 respectively)

ALLOWABLE STRENGTH DESIGN (ASD)

PASD (lb)

PC6300 PC6400 PC6600 PC8300 PC8400 PC8500

VASD-x

(lb)VASD-z (lb)

VASD-x

(lb)VASD-z (lb)

VASD-x

(lb)VASD-z (lb)

VASD-x

(lb)VASD-z (lb)

VASD-x

(lb)VASD-z (lb)

VASD-x

(lb)VASD-z (lb)

625056255000

232622922259

231622832249

288128472813

311130743037

269626622628

284728122776

320131643128

290028672834

399139543918

394139053869

474547084672

492448864848

437537503125

222521912157

221521812148

277927452711

300129642927

259425602526

274027042668

309130543018

280027672734

388138453808

383237963760

463545984562

481047714733

250018751250

212320892055

211420802046

267726432609

289128542817

249224582425

263225962561

298129442908

270126682635

377137353698

372436883652

452544884452

469546574619

6250

-625-1250

2021198718521716

2013197918441709

2575254124052270

2780274425972450

2391235722212085

2525248923452202

2871283526882542

2601256824352303

3662362534783332

3615357934353290

4415437842324085

4581454343914239

-1875-2500-3125

158014451309

157414391303

213419981862

230421572010

194918131677

205819151772

239522492102

217020371905

318630392893

314530012856

393837923645

408739343782

© 2020 Perma-Column, LLC All rights reserved.

BUILD BETTER Perma-Column® outperforms treated wood — guaranteed

Insist on the environmentally friendly solution that will outlast a treated wood foundation every time. Only Perma-Column® precast concrete columns provide your building a foundation engineered to last for generations to come.

BUILD STRONGER Perma-Column® is 3x stronger than concrete

Perma-Column® piers are precast concrete, reinforced with 60,000 psi rebar welded to a ¼” steel bracket. Perma-Column® is the unmatched post-frame foundation solution for homes and municipal, commercial, and agricultural buildings.

BUILD TO LAST Perma-Column® protects the value of your building

Post-frame construction materials have come a long way. Your building deserves the lasting durability of a permanent foundation. Perma-Column® is engineered to protect the structural integrity of your post-frame building and is backed by a lifetime warranty.

www.permacolumn.com

400 Carol Ann Lane, Ossian, IN 46777 | Tel: 800 622-7190 | Fax: 260 622-7192

BUILD ON A PERMANENT FOUNDATION Build with Perma-Column®