Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft...

21
BREMEN 1st September, 2016 ION AROCENA DE LA RÚA Nabrawind Project Manager ANTONIO UGARTE CENER Wind Energy Director www.nabrawind.com www.cener.com Advanced Validation Strategy for Nabrawind Self Erected Tower

Transcript of Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft...

Page 1: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

BREMEN

1st September, 2016

ION AROCENA DE LA RÚA

Nabrawind Project ManagerANTONIO UGARTE

CENER Wind Energy Directorwww.nabrawind.com

www.cener.com

Advanced Validation Strategy for Nabrawind Self Erected Tower

Page 2: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

NABRAWINDAdvanced Wind Technologies

1 Introduction

Drastic Cost Reduction

Modularity Proven Technologies

Modular Blade Joint

Self Erected Tower

Nabrawind Introduction

Page 3: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

1 Introduction

Cost Increase€HH140=1.6·€HH100

Most Expensive Component HH>120

LogisticsRoads / Bridges Limiting Concepts

Assembly CranesLack of AvailabilityLarge Mobilization and Rental Costs

Installation RateNew Concepts Delaying Wind Farm Installation Rates

WTG IntegrationControl Challenges in Soft-Soft TowersSoft-Stiff Unfeasible for XXL Steel Towers

XXL Tower Challenges

Page 4: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

2 XXL Tower Alternatives Evaluation

TubularSteel

SegmentedSteel

PrecastConcrete or

HybridLattice Nabrawind

SET

Tower Cost

Logistics

Assembly & Erection

Modal Coupling

Operation Proven Life

Good Poor

Page 5: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

Nabrawind SET

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

Client WTG

Client WTG

Page 6: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

80 100 120 140 160 180

Tota

l Cos

t [k€

]

Hub Height [m]

Tower + Installation Cost

Steel Tubular

Hybrid Tubular

NBW -30%+40m

Page 7: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

Self ErectionNo Large Cranes

Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly

Page 8: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

Self ErectionNo Large Cranes

Fast Assembly2-Days WTG Erection (Wind >15m/s)Prefab Foundation (T<0ºC)

0 5 10 15

SET160m

Concrete140m

Steel100m

Steel60m

Installation Days

Crane Inst

WTG Inst.

Crane Des

WTG Installation Sequence (no Foundation)

0 10 20 30 40 50 60

SET160m

Concrete140m

Steel100m

Steel60m

Installation Days

FoundationFound. CuringCrane InstWTG Inst.Crane Des

WTG Installation Sequence

Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly

Page 9: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

Self ErectionNo Large Cranes

Fast Assembly2-Days WTG ErectionPrefab Foundation

Easy WTG IntegrationSoft-Stiff Tower H>180No Functional Affection

Freq

uenc

y [H

z]

Rotor speed [rpm]

1P

3P

6P

1st Bending

2nd Bending

1st Torsion

⍉130 HH160 Campbell Diagram

Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly

Page 10: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

3 Nabrawind Self Erected TowerAdvanced Lattice Structure

Simple Logistics and OperationPackable in Standard 40ft ContainersMaintenance Free Structure and Connections

Self ErectionNo Large Cranes

Fast Assembly2-Days WTG ErectionPrefab Foundation

Easy WTG IntegrationSoft-Stiff Tower H>180No Functional Affection

Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly

Page 11: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

TubularSteel

SegmentedSteel

PrecastConcrete or

HybridLattice Nabrawind

SET

Tower Cost

Logistics

Assembly & Erection

Modal Coupling

Operation Proven Life

Nabrawind Self Erected TowerTower Alternatives Comparison3

Page 12: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

4 CENER Introduction21 M€ In 2016 the annual budget is

20,5€ million. 70% self-financing

190 190 employees

100 M€ Total investments (2002-2016): ~ 101€ million

NUMBERS:• Wind Power• Photovoltaic• Solar thermal• Biomas• Grid integration• Bioclimatic architecture

AREAS

Page 13: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

5 Advanced Tower Validation WTG Blades vs Towers Validation Strategy Comparison

FullScaleTests

SubcomponentTests

Coupon Tests

WTG Blades

Component Verification √

Design Details

Validation√

Material Allowables Definition

Page 14: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

5 Advanced Tower Validation WTG Blades vs Towers Validation Strategy Comparison

FullScaleTests

SubcomponentTests

Coupon Tests

WTG Blades

WTGTowers SET

Component Verification √ X √

Design Details

Validation√ ∼ √

Material Allowables Definition

√ ∼ √

Page 15: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

6 Fatigue Full Scale Tower TestTest Objectives

Tower & Foundation Accelerated Proven Life

0

5

10

15

20

25

0 5 10 15 20

Ope

rativ

e Pr

oven

Life

[yea

rs]

Time [years]

Accelerated Test

Operational Proven Life Acceleration

Conventional Operation

Page 16: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

6 Fatigue Full Scale Tower TestTest Setup

Hot SpotsLattice Members

Foundation SettlementBolt Preload Control

Tower Head MassTower Head Exciter

Strain GaugesLVDTLVDT

Bolt Load Sensors

Page 17: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

6 Fatigue Full Scale Tower TestTest Design

Tow

er H

eigh

[m]

Bending Moment Ranges [kNm]

20y Design Loads20y Eq. Test LoadsFinal Test Loads

γt

Full Scale Test Load Distribution

Tower DesignFatigue Loads20/25 years

Test EquivalentLoads

>20/25 years

Test Loads

Damage-Equivalent Ranges Analysis

IEC61400-23 based Test Factor (γt):- Conseq. Failure- Tower Variation- Fatigue Formulation

Page 18: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

7 XXL Tower Alternatives EvaluationAfter SET Full-Scale Test

TubularSteel

SegmentedSteel

PrecastConcrete or

HybridLattice Nabrawind

SET

Tower Cost

Logistics

Assembly & Erection

Modal Coupling

Operation Proven Life

Page 19: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

Tower Tests

8 Nabrawind Self Erected Tower ProjectProject Summary

Design Certificate

2015 2016

Company / Project Funding

SET TechnologyDevelopment

HH160 Tower Detailed Design

2017 2018

HH160 Tower Prototype Manuf. & Erection

Tower Certificate

TowerPreserials

Page 20: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

8 Nabrawind Self Erected Tower ProjectProject Summary

Page 21: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower

Thanks for your Attention

www.nabrawind.com

www.cener.com