Adalet Catalog Draft Increased Safety VH4X VC4X METER HOUSINGS ADALET.COM ©Adalet AdAleT enclosure...

9
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet EXPLOSIONPROOF METER HOUSINGS 229 Explosionproof Meter Housings Contents Explosionproof Meter Housings Screw Cover 230 Window Screw Cover 238 Dome Cover 247 Drilling & Tapping Guidelines 255

Transcript of Adalet Catalog Draft Increased Safety VH4X VC4X METER HOUSINGS ADALET.COM ©Adalet AdAleT enclosure...

EXPLOSIONPROOF METER HOUSINGS

SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet

SCREW COVER

EXPL

OSI

ON

PRO

OF

MET

ER H

OU

SIN

GS

229

Explosionproof Meter Housings

ContentsExplosionproof Meter Housings Screw Cover 230

Window Screw Cover 238

Dome Cover 247

Drilling & Tapping Guidelines 255

EXPLOSIONPROOF METER HOUSINGS

ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet

SCREW COVER

EXPLOSIO

NPR

OO

FM

ETER H

OU

SING

S

230

Screw Cover Explosionproof Meter Housings

XJDH N44 1/8” x 4 1/8” x 3”

Cover Opening 3 3/4”

XJDAH N45 3/4” x 5 3/4” x 4 7/8”

Cover Opening 4 3/16”

XJSH N4(Tapped on side pads only)

4” I.D. x 2 22/32” depthCover Opening 4”

XJLH N46” x 6” x 3 9/16”

Cover Opening 5 3/8”

XJTH N45 13/16” x 6 9/16” x 4”

Cover Opening 5 3/8”

XJHAH N47 3/16” x 9 3/16” x 4”Cover Opening 7”

XJMCH N46 3/4” x 6 3/4” x 3”

Cover Opening 7”

XJMAH N46 3/4” x 6 3/4” x 5”

Cover Opening 7”

XJMH N46 3/4” x 6 3/4” x 8”

Cover Opening 7”

XJXH N44 7/8” x 4 7/8” x 3 1/16”Cover Opening 4 3/4”

XJKAH N49 1/2” x 11 1/2” x 8 1/8”Cover Opening 9”

XJKH N49 1/2” x 11 1/2” x 6 1/8”Cover Opening 9”

XJHCH N47 3/4” x 10 5/16” x 5”Cover Opening 7”

XJHBH N47 1/4” x 9 1/8” x 6”

Cover Opening 7”

XJNH 6 & 12 N411 1/2” x 12 3/4” x 6(12)”Cover Opening 10 3/4”

• Drilled and tapped to specification, attach layout sheet. • Dimensions are nominal internal.

A

E

C

BD

H

G

K

JF

A

E

C

BD

H

G

K

JF

XJWHH N46 7/8” I.D. x 4 7/8” D

Cover Opening 6 7/8”

XJWTH N45 3/8” I.D. x 3 3/4” D

Cover Opening 5 3/8”

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet

sCrEW CoVEr

EXPL

OSI

ON

PRO

OF

MET

ER H

OU

SIN

GS

231

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GClass IIIClass I, Zone 1, AEx d IIB+H2Ex d IIB+H20539 II 2GD (Optional)*EEx d IIB+H2 (Optional)*IP 66NEMA Type 4

*specify ATEX if required

UL 1203CSA C22.2 No. 25 & 30 UL 60079-0/UL 60079-1CSA 60079-0/CSA 60079-1ATEX Directive 94/9/ECEN 50014, EN50018IEC 60529

UL 50

CERTIFICATIONS

Screw Cover Explosionproof / flameproof Meter Housings

A

E

C

BD

H

G

K

JF

A

E

C

BD

H

G

K

JF

XJDHX N44 1/8” x 4 1/8” x 3”

Cover Opening 3 3/4 ”

XJDAHX N45 3/4 ” x 5 3/4 ” x 4 7/8”

Cover Opening 4 3/16”

XJSHX N4(Tapped on side pads only)

4” I.D. x 2 22/32” depthCover Opening 4”

XJLHX N46” x 6” x 3 9/16”

Cover Opening 5 3/8”

XJTHX N45 13/16” x 6 9/16” x 4”

Cover Opening 5 3/8”

XJHAHX N47 3/16” x 9 3/16” x 4”Cover Opening 7”

XJMCHX N46 3/4 ” x 6 3/4 ” x 3”

Cover Opening 7”

XJMAHX N46 3/4 ” x 6 3/4 ” x 5”

Cover Opening 7”

XJMHX N46 3/4 ” x 6 3/4 ” x 8”

Cover Opening 7”

XJXHX N44 7/8” x 4 7/8” x 3 1/16”

Cover Opening 4 3/4”

XJKAHX N49 1/2 ” x 11 1/2 ” x 8 1/8”Cover Opening 9”

XJKHX N49 1/2 ” x 11 1/2 ” x 6 1/8”Cover Opening 9”

XJHCHX N47 3/4 ” x 10 5/16” x 5”Cover Opening 7”

XJHBHX N47 1/4 ” x 9 1/8” x 6”

Cover Opening 7”

XJNHX 6 & 12 N411 1/2 ” x 12 3/4 ” x 6(12)”Cover Opening 10 3/4 ”

XJWHHX N46 7/8” I.D. x 4 7/8” D

Cover Opening 6 7/8”

XJWTHX N45 3/8” I.D. x 3 3/4 ” D

Cover Opening 5 3/8”

• Drilled and tapped to specifi cation, attach layout sheet. • Dimensions are internal.

EXPLOSIONPROOF METER HOUSINGS

ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet

sCrEW CoVEr

EXPLOSIO

NPR

OO

FM

ETER H

OU

SING

S

232

XJDH N4XJDHX N4

XJDAH N4XJDAHX N4

XJSH N4XJSHX N4

*XJS can be tapped on side pads only.

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

5 1⁄83 ¾

34 5⁄8

3 11⁄166 3⁄165 1⁄84 1⁄8

6 ¾5 ¼

4 7⁄86 5⁄8

4 3⁄168 3⁄86 ¾5 ¾

3 ¾4 7⁄16

4 5⁄322 23⁄32

4

4 7⁄163 ¾

¾

5 1⁄83 ¾

34 5⁄8

3 11⁄166 3⁄165 1⁄84 1⁄8

6 ¾5 ¼

4 7⁄86 5⁄8

4 3⁄168 3⁄86 ¾5 ¾

3 ¾4 7⁄16

4 5⁄322 23⁄32

4

4 7⁄163 ¾

¾

Screw Cover Explosionproof Meter Housings

STANDARD FEATURES

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJDH N4

XJDAH N4

XJSH N4*

2

1

1

4 1/8

5 3/4

4

4 1/8

3 3/4

-

3

4 7/8

2 23/32

3 3/4

4 3/16

4

7/16

7/16

5/16

5 1/2

11 1/2

2 3/4

NOMINAL DIMENSIONS

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet

sCrEW CoVEr

EXPL

OSI

ON

PRO

OF

MET

ER H

OU

SIN

GS

233

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)XJLH N4

XJLHX N4

XJTH N4XJTHX N4

XJXH N4XJXHX N4

8 3⁄8

5 ¼

7

6

6 7

5 7⁄83 9⁄16

5 3⁄8

6 9⁄166

4

7 7⁄16

5 13⁄16

6 11⁄16

7 ¾

6 7⁄16

5 ¾

4 7⁄8

5 ¾

6 ¾

4 ¾

4 ¾

5 ¾

5 1⁄163 1⁄16

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJLH N4

XJTH N4

XJXH N4

2

2

2

6

5 13/16

4 7/8

6

6 9/16

4 7/8

3 9/16

4

3 1/16

5 3/8

5 3/8

4 3/4

7/16

1/2

11/2 3

9 1/2

11

6 1/4

NOMINAL DIMENSIONS

STANDARD FEATURES

Screw Cover Explosionproof / flameproof Meter Housings

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet

sCrEW CoVEr

EXPLOSIO

NPR

OO

FM

ETER H

OU

SING

S

234

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

Screw Cover Explosionproof Meter Housings

STANDARD FEATURES

XJMH N4XJMHX N4

XJMAH N4XJMAHX N4

XJMCH N4XJMCHX N4

9 1⁄8

4

6 ¼

7 ¾

11 ¾

6 ¾

7 ¾6 ¾

7

9 1⁄8

5

6 ¼

7 ¾

8 ¾

6 ¾

7 ¾6 ¾

7

9 1⁄8

3

6 ¼

7 ¾

6 ¾

6 ¾

7 ¾

6 ¾

7

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJMH N4

XJMAH N4

XJMCH N4*

2

2

2

6 3/4

6 3/4

6 3/4

6 3/4

6 3/4

6 3/4

8

5

3

7

7

7

7/16

7/16

5/16

21 1/2

16 1/2

14 1/2

NOMINAL DIMENSIONS

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet

sCrEW CoVEr

EXPL

OSI

ON

PRO

OF

MET

ER H

OU

SIN

GS

235

XJHAH N4 XJHAHX

XJHBH N4XJHBHX N4

XJHCH N4 XJHCHX N4

4

9 ¾

10 3⁄16

6 9⁄16

9 3⁄16

8 3⁄16

7 3⁄16

7

8 ¾

6

9 ¾

10 ¼

8 11⁄16

9 1⁄16

8 3⁄8

7 ¼

7

8 7⁄8

10 ¼

11 7⁄16

7 9⁄16

10 5⁄16

8 7⁄8

7 ¾

7

7 ¾

5 11⁄16

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJHAH N4

XJHBH N4

XJHCH N4

2

2

2

7 3/16

7 1/4

7 3/4

9 3/16

9 1/8

10 5/16

4

6

5

7

7

7

9/16

9/16

9/16

16 1/2

22

18

NOMINAL DIMENSIONS

STANDARD FEATURES

Screw Cover Explosionproof / flameproof Meter Housings

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet

sCrEW CoVEr

EXPLOSIO

NPR

OO

FM

ETER H

OU

SING

S

236

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated.• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

Screw Cover Explosionproof Meter Housings

STANDARD FEATURES

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJKH N4

XJKAH N4

3

3

9 1/2

9 1/2

11 1/2

11 1/2

6 1/8

8 1/8

9

9

9/16

9/16

40

44

NOMINAL DIMENSIONS XJKH N4XJKHX N4

XJKAH N4XJKAHX N4

12 3⁄8

11 ½

6 1⁄8

9 ½

9 1⁄8

10 ¾

8

12 ¾

9 1⁄8

12 3⁄8

11 ½

8 1⁄8

9 ½

9 1⁄8

10 ¾

8

12 ¾

11 1⁄8

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS

EXPLOSIONPROOF METER HOUSINGS

SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet

sCrEW CoVEr

EXPL

OSI

ON

PRO

OF

MET

ER H

OU

SIN

GS

237

A

E

C

BD

H

G

K

JF

A

E

C

BD

H

G

K

JF

XJWHH N4XJWHHX N4

A

E

C

BD

H

G

K

JF

XJWTH N4XJWTHX N4

A

E

C

BD

H

G

K

JF

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated.• A large cover opening enhances mounting pan installation.• Two depths available for a wider selection of effi cient component packaging• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

14 3⁄8

11 ½

16 ¾

10 ¾

12 ¾9

13 1⁄8

XJNH N4XJNHX N4

Screw Cover Explosionproof Meter Housings

STANDARD FEATURES

• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum size as indicated.• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)

NOMINAL DIMENSIONS (Inches)

CAT. NUMBER A B C D E F G H J K

XJWHH N4 7-3/4 7 3/4 6 3/8 6 3/8 7/16 5 5/8 4 9/16 1 13/16 1 3/4 7 7/8

XJWTH N4 6 1/4 6 1/4 5 1/8 5 1/8 3/8 5 1/8 4 1 1/2 1 7/16 6 3/8

STANDARD FEATURES

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.W L D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJNH 6

XJNH 12

4

4

11 1/2

11 1/2

12 3/4

12 3/4

6

12

10 3/4

10 3/4

5/8

5/8

61

85

NOMINAL DIMENSIONS

CAT. NUMBER CONDUIT SIZE

INSIDE DIM.Dia. D

DIAMETER COVER

OPENING

MOUNTING HOLE SIZE

WEIGHT(LBS)

XJWHH N4

XJWTH N4

2 1/2

2

6 7/8

5 3/8

4 7/8

3 3/4

6 7/8

5 3/8

7/16

3/8

8 1/2

7 1/2

NOMINAL DIMENSIONS

OVERALLHEIGHT

9 13/16

13 5/16

UL 1203CSA C22.2 No. 25 & 30 UL 50

Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4

CERTIFICATIONS