WSAA Product Appraisal 14/02 1
COPYRIGHT
Acu-Tech Piping Systems PRODUCT APPRAISAL REPORT 14/02
Maxiplast Polyethylene (PE) Pressure Pipe
AS/NZS 4130:2009 Polyethylene pipes for pressure applications
Publication Date 18 June 2014
WSAA Product Appraisal 11/08 Issue 2 2
COPYRIGHT
Document History
The following information indicates the changes made to this document.
Date Version File Location
13 May 2014 Peer Review draft
U:\PP1 Industry Performance and Regulation\PP1-012 Product Appraisals\Civil Asset Infrastructure\2014\PA 1402 Acu-Tech Piping Systems - Maxiplast Polyethylene\Maxiplast PE Appraisal Draft 6-5-14.docx
19 June 2014 Publication version
U:\PP1 Industry Performance and Regulation\PP1-012 Product Appraisals\Civil Asset Infrastructure\2014\PA 1402 Acu-Tech Piping Systems - Maxiplast Polyethylene\Final\PA
1402 Maxiplast PE Appraisal final.docx
Peer Reviewers
Name/Title Organisation Date
Peter Pittard, Contractor WSAA 7/5/2014
Carl Radford, Product Appraisal Manager WSAA 12/5/2014
Adam Glasson, Technical Officer Goulburn Valley Water 14/5/2014
Mohamed Yoosuf, Senior Engineer, Standards City West Water 27/5/2014
David Moore, Manager, Design City West Water 27/5/2014
Colin Paxman - Manager Products and Standards South East Water 2/6/2014
Approvals
Name/Title Signature Date
Carl Radford, Product Appraisal Manager Carl Radford 19/6/2014
WSAA Product Appraisal 14/02 3
COPYRIGHT
Overview of WSAA
The Water Services Association of Australia (WSAA) is the peak body of the Australian
urban water industry. Its members and associate members provide water and wastewater
services to approximately 16 million Australians and to many of our largest industrial and
commercial enterprises.
Urban water service providers have a critical role in ensuring that Australians have access
to adequate and high quality water services. As Australia‟s population continues to grow,
with most of this growth occurring in cities, that role becomes increasingly important.
WSAA‟s vision is for Australian urban water utilities to be valued as leaders in the
innovative, sustainable and cost effective delivery of water services. WSAA strives to
achieve this vision by promoting knowledge sharing, networking and cooperation amongst
members. WSAA identifies emerging issues and develops industry-wide responses. WSAA
is the national voice of the urban water industry, speaking to government, the broader
water sector and the Australian community.
Copyright
This document is copyrighted. Apart from any use as permitted under the Copyright Act
1968, no part of this document may be reproduced or transmitted in any form or by any
means, electronically or mechanical, for any purpose, without the express written
permission of the Water Services Association of Australia Limited.
© Copyright 2014 by WATER SERVICES ASSOCIATION of Australia Limited All rights
reserved.
WSAA Product Appraisal 14/02 4
COPYRIGHT
CONTENTS
1 EXECUTIVE SUMMARY ............................................................................................................................................. 5
1.1 Recommendations ................................................................................................................................................ 5
2 THE APPLICANT ......................................................................................................................................................... 6
3 THE PRODUCT ........................................................................................................................................................... 6
4 SCOPE OF THE APPRAISAL ..................................................................................................................................... 6
5 APPRAISAL CRITERIA ............................................................................................................................................... 7
5.1 General.................................................................................................................................................................. 7
5.2 Quality Assurance Requirements .......................................................................................................................... 7
5.3 Performance Requirements................................................................................................................................... 7
6 COMPLIANCE WITH APPRAISAL CRITERIA............................................................................................................. 7
6.1 Compliance with Quality Assurance Requirements ............................................................................................... 7
6.2 Compliance with Performance Requirements ....................................................................................................... 8
6.2.1 Polyethylene (PE) compounds ........................................................................................................................ 8
6.2.2 Testing of pipes .............................................................................................................................................. 8
6.2.3 Suitability for contact with drinking water ........................................................................................................ 9
6.2.4 Colour coding .................................................................................................................................................. 9
7 FITTING INSTRUCTIONS, TRAINING AND INSTALLATION ..................................................................................... 9
8 PRODUCT MARKING ................................................................................................................................................. 9
9 PACKAGING AND TRANSPORTATION ................................................................................................................... 10
10 PRODUCT WARRANTY .......................................................................................................................................... 10
11 WATER AGENCY EXPERIENCE WITH THE PRODUCT OR FIELD TESTING REPORT ..................................... 10
12 LIFE EXPECTANCY ................................................................................................................................................ 11
13 DISCLAIMER ........................................................................................................................................................... 11
13.1 Issue of Report .................................................................................................................................................. 11
13.2 Limits on Reliance on Information and Recommendations................................................................................ 11
13.2.1 Disclaimer of liability ................................................................................................................................... 11
13.2.2 Need for independent assessment ............................................................................................................. 12
13.3 No Updating ...................................................................................................................................................... 12
13.4 No Warranty ...................................................................................................................................................... 12
APPENDIX A - QUALITY CERTIFICATIONS ............................................................................................................... 13
APPENDIX B - WSAA PRODUCT SPECIFICATION .................................................................................................... 19
APPENDIX C - SUPPLIER CONTACTS ....................................................................................................................... 21
WSAA Product Appraisal 14/02 5
COPYRIGHT
1 EXECUTIVE SUMMARY
The Acu-Tech Group is a manufacturer and supplier of high performance, thermoplastic
pipeline systems for fluid and gas transfer and cable protection. Products are
manufactured primarily from polyethylene and polypropylene materials and are utilized for
a wide range of applications in plumbing, mining, civil and mechanical services markets.
Established in 2000, the Acu-Tech Group is a privately owned and operated company
based in Maddington, Perth WA and Tullamarine, Melbourne Victoria. The group consists
of Maxiplast, the manufacturer of polyethylene pipe and fittings and Acu-Tech Piping
Systems, the sales and distribution division for the Maxiplast range of products.
This Appraisal covers Series 1 PE100 plain walled pipes manufactured by Maxiplast in
compliance with AS/NZS 4130:2009 – Polyethylene (PE) pipes for pressure applications.
The range includes Series 1 PE100 plain walled pipes in sizes from DN 20 up to DN 800
and a wide range of pressure classifications up to and including PN 25.
Acu-Tech Group Series 1 PE Pipe has the following applications for Water Agencies:
• reticulation (pressure drinking1 water supply and gravity, pressure and vacuum
sewerage)
• property services (water supply and sewerage)
Pipes are offered in lengths of 6m, 12m and 20m for all sizes, in coiled lengths of 50m,
100m, 150m and 200m for sizes DN20 to DN125 and in coiled lengths of 100m for sizes
>DN125 and ≤ DN160.
The pipe brands submitted for appraisal are as detailed below although other colour
options can be provided on request.
Brand Colour Coding Application
Acu-Water Black with Blue stripes Drinking Water
Acu-Sewer Black with Cream Stripes or with Cream Internal Jacket
Pressure Sewer (also suitable for non-pressure sewer)
Recycle –Tech
Black with Purple Stripes or with Purple Outer Jacket
Recycled Water
Acu-Black Plain Black Multi-purpose
Acu-Tech and Maxiplast both have Quality Management certification to ISO 9001:2008.
Maxiplast has Type 5 Product Certification (ApprovalMark) and WaterMark certification for
its range of PE100 pipes.
Plastic pipeline systems are commonly designed on the basis of 50 year extrapolated
material test data. For correctly manufactured and installed systems, the actual life cannot
be predicted, but can reasonably be expected to be well in excess of 100 years before
major rehabilitation is required. Pipe life expectancy can vary with the quality of
installation workmanship, system operating conditions and other site-specific factors.
This appraisal concludes that Maxiplast PE100 pipe is „fit for purpose‟ and is suitable for
use in water supply reticulation networks, recycled water applications and pressure
sewerage applications including vacuum sewerage.
1.1 Recommendations
It is recommended that WSAA members and associates accept/authorise Maxiplast pipes
as listed in Section 4 – „Scope of the Appraisal‟ and in conjunction with the ApprovalMark
Schedule. The recommendation is subject to the pipes being designed, installed, tested,
WSAA Product Appraisal 14/02 6
COPYRIGHT
commissioned and tapped in accordance with Maxiplast recommendations, appropriate
WSAA Codes, Technical Notes and nominated Standards.
2 THE APPLICANT
The Acu-Tech Group is a manufacturer and supplier of high performance, thermoplastic
pipeline systems for fluid and gas transfer and cable protection. Products are
manufactured primarily from polyethylene and polypropylene materials and are utilized for
a wide range of applications in plumbing, mining, civil and mechanical services markets.
Established in 2000, Acu-Tech is a privately owned and operated company based in
Maddington, Western Australia.
The group consists of Maxiplast, the manufacturer of polyethylene pipe and fittings and
Acu-Tech Piping Systems, the sales and distribution division for the Maxiplast range of
products.
Acu-Tech provides the complete pipeline system package including valves, fusion welding
equipment, training, QA and technical support.
Polyweldtech, a wholly owned subsidiary company, provides fusion weld training and
quality assurance services and also operates a fully equipped NATA accredited laboratory,
providing material and destructive weld testing services.
Acu-Tech also has a sales and distribution centre in Melbourne VIC at Tullamarine.
3 THE PRODUCT
Maxiplast PE100 plain ended pipe is product certified for compliance with AS/NZS
4130:2009 by Approval Mark International (ApprovalMark Certificate No. AMI 74541 and
WaterMark Certificate No. WMKA22040). The product is based on black, fully
compounded PE100 resin compliant to AS/NZS 4131:2010, and all jacket/stripe coloured
resin is also based on fully compounded PE100 resin. The final compound is in
compliance with AS/NZS 4130:2009 section 7.3 “Striping and jacket compounds”.
Maxiplast PE pipe is available as solid black, black with coloured stripes, or black with
coloured jacket.
4 SCOPE OF THE APPRAISAL
This product appraisal applies to Maxiplast PE pressure pipe manufactured to AS/NZS
4130:2009 Polyethylene (PE) pipes for pressure applications for use in water supply,
recycled water supply and sewerage systems as described below:
(a) Series 1
(b) Material Classification: PE100 (HDS 8 MPa)
(c) Pressure Classes: PN 6.3, PN 8, PN 10, PN 12.5, PN 16, PN 20 and PN 25 as
defined in AS/NZS 4130 Clause 6.
(d) Sizes: DN 20 to DN 800 as defined in AS/NZS 4130 Table 2
(e) Pipe Length: 6 m, 12 m or 20 m
(f) Coil Length: DN 20 to DN 125 – 50 m, 100 m, 150 m and 200 m; >DN 125 to ≤ DN
160 – 50 m and100 m.
The pipe brands submitted for appraisal are as detailed in Table 1 below:
WSAA Product Appraisal 14/02 7
COPYRIGHT
TABLE 1 MAXIPLAST PE PIPE BRANDS
Brand Colour Coding Application
Acu-Water Black with Blue stripes Drinking Water
Acu-Sewer Black with Cream Stripes or with Cream Internal Jacket
Pressure Sewer (also suitable for non-pressure sewer)
Recycle –Tech
Black with Purple Stripes or with Purple Outer Jacket
Recycled Water
Acu-Black Plain Black Multi-purpose
Pipe included in the Scope is listed on the ApprovalMark Schedule shown in Appendix A.
5 APPRAISAL CRITERIA
5.1 General
Appraisal criteria is determined by the WSAA Infrastructure Products and Materials
Network and regularly reviewed to ensure that the criteria reflect the requirements of
WSAA members.
5.2 Quality Assurance Requirements
The WSAA product appraisal network accepts polyethylene pipe manufactured in
compliance with AS/NZS 4130 and duly verified by means of an ISO Type 5 product
certification scheme undertaken by a JAS-ANZ accredited Conformity Assessment Body
(CAB) or by means of an equivalent international accreditation system recognised by JAS-
ANZ.
The manufacturer is generally expected to have a production management and control
system that has been duly accredited in accordance with AS/NZS ISO 9001, as a
prerequisite to undergoing a product certification audit.
5.3 Performance Requirements
Maxiplast PE100 pressure pipe has been appraised for compliance with AS/NZS
4130:2009 Polyethylene (PE) pipes for pressure applications.
Readers are also referred to the following WSAA “National Codes List” :
WSA 01-2004 Polyethylene Pipeline Code
The WSAA Product Specifications that are most relevant to this application are as follows:
(a) WSA PS-207 – Polyethylene (PE) Pipes for Pressure Applications – Water Supply
and Sewerage
(b) WSA PS-215 – Polyethylene (PE) Property Service Pipes for Pressure Applications –
Water Supply.
To view or download a copy WSA PS-207 and WSA PS-215 visit the WSAA website. A
copy of WSA PS-207 and WSA PS-215 has also been attached as Appendix B.
6 COMPLIANCE WITH APPRAISAL CRITERIA
6.1 Compliance with Quality Assurance Requirements
Maxiplast holds a Quality Management System certification complying with ISO 9001:2008
as demonstrated by Certificate No. QMS 75367, issued by Approval Mark International, for
the manufacture and supply of quality polyethylene pipes and conduits for pressure and
non-pressure applications. Acu-Tech Piping Systems is also licensed to ISO 9001:2008
by SAI-Global, Certificate No. QEC29280, for the supply of piping systems and
components.
WSAA Product Appraisal 14/02 8
COPYRIGHT
6.2 Compliance with Performance Requirements
6.2.1 Polyethylene (PE) compounds
Maxiplast manufactures PE pipe using polyethylene compound PE100 complying with
AS/NZS 4131:2010.
The PIPA Polyolefin Technical Committee has evaluated available compounds used for
PE pipe including for coloured pipe jacket and stripe production and has listed compliant
materials in its Industry Guideline POP004. Maxiplast has provided documentation to
demonstrate that the materials utilised in their pipe production are contained within
POP004.
6.2.2 Testing of pipes
The material compounds utilised, process verification and batch release test results
confirm that the pipe meets the requirements of AS/NZS 4130:2009.
Batch release testing is done in-house on appropriate specialised testing equipment.
Maxiplast has provided copies of Type Test reports conducted by Vipac Plumbing
Products Laboratory and Chisolm Institute to demonstrate compliance with the
requirements of AS/NZS 4130. AMS Laboratories completed testing for compliance to
AS/NZS4020. All laboratories are NATA accredited.
Table 2 summarises the Type Testing results.
TABLE 2
TYPE TESTING RESULTS
Requirement Clause Requirement Result Pipe Size
Dimensional Measurements
9.1, 9.4 Geometrical characteristics for diameter, wall thickness and out-of-roundness
Vipac Reports 602946-1 602947-2 263744-1 Complies
DN25 DN63 DN160
Effect on water 9.6 Comply with AS/NZS4020 AMS Report 1004028 Complies
DN20
Resistance to internal
pressure at 80⁰C. 10.1
Withstand 5.4MPa hydrostatic pressure at 80° C for 165h
Vipac Reports 602946-1 602947-2 263744-1 Complies
DN25 DN63 DN160
Resistance to internal
pressure at 80⁰C. 10.1
Withstand 5.0MPa hydrostatic pressure at 80° C for 1000h
Vipac Reports 602946-1 602947-2 263744-1 Complies
DN25 DN63 DN160
Reversion 10.2 ≤ 3% when tested at 110⁰C
Vipac Reports 602946-1 602947-2 263744-1 Complies
DN25 DN63 DN160
Thermal stability 10.3 Oxidation induction time ≥
20 min at 200⁰C.
Chisolm Report 207/11 Complies
DN25 DN63 DN160
Slow crack growth resistance PE100 SDR11
10.4 ≥500 Hours when tested at 920kPa Pressure
Vipac Report 594110-0 Complies
DN 110
WSAA Product Appraisal 14/02 9
COPYRIGHT
6.2.3 Suitability for contact with drinking water
Maxiplast PE100 pressure pipe complies with the requirements of AS/NZS 4020:2005
Test report No. 1004028, from AMS Laboratories, was submitted for DN 20 PE100 Series
1 SDR11 PN16 Pressure Pipe to demonstrate compliance with AS/NZS 4020:2005 –
Product for use in contact with drinking water.
6.2.4 Colour coding
Maxiplast PE100 pressure pipe complies with the colour coding scheme specified in
AS/NZS 4130:2009, i.e.:
(a) Solid black pipe with blue stripes no darker than RAL 5012 for drinking water supply
reticulation networks.
(b) Solid black pipe with purple stripes or jackets no lighter than RAL 310 70 15 nor
darker than RAL 330 40 40 for recycled water applications.
(c) Solid black pipe with cream stripes or jackets no lighter than RAL 080 90 20 nor
darker than RAL 075 80 20 for sewerage applications.
7 FITTING INSTRUCTIONS, TRAINING AND INSTALLATION
PE pressure pipe has been a commonly used product in the urban water industry for many
years. Maxiplast PE pipe is compatible with fittings manufactured in accordance with
AS/NZS 4129:2008 Fittings for polyethylene pipes for pressure applications.
For specific design and installation information relating to PE pressure pipelines and PE
gravity pipelines refer to the WSAA Polyethylene Pipeline Code - WSA 01 available at the
WSAA web site www.wsaa.asn.au or AS/NZS 2033:2008 Installation of polyethylene pipe
systems.
Electrofusion welding, butt fusion and mechanical compression fittings may be used for
joining pipe-to-pipe or fitting-to-pipe. All welding shall be performed by welders who have
successfully completed training by a Registered Training Organisation, endorsed by the
Plastics Industry Pipe Association for the relevant welding method(s).
The Plastics Industry Pipe Association provides technical guidelines for jointing in the
following documents.
(a) POP001 Electrofusion Jointing of Pipe and fittings for Pressure Applications.
(b) POP003 Butt Fusion Jointing of PE Pipes and Fittings – Recommended Parameters.
POP001 contains recommendations for equipment required, for jointing, maintenance,
servicing and calibration procedures, records to be kept and the training program to be
respected to produce good fusion joints in polyethylene pipes.
POP003 is a guide to the butt fusion of polyethylene pipe using AS/NZS 4130 material as
a basis, recommending the butt fusion procedures and parameters as specified in ISO
21307.
Copies of these documents can be downloaded from the PIPA website www.pipa.com.au.
8 PRODUCT MARKING
Maxiplast pipes are marked in accordance with the requirements of AS/NZS 4130:2009 as
follows:
Manufacturers Name: ACU-TECH
Trademark: ACU-WATER, ACU-SEWER, RECYCLE-TECH, ACU-BLACK
Product Code: e.g. PBS18011006
Pipe Series Number: S1
WSAA Product Appraisal 14/02 10
COPYRIGHT
Nominal outside diameter, classification and SDR: e.g. DN180 PN16 SDR11
PE material classification: PE100
Date of manufacture using the ISO system: e.g.140401 (i.e. 1st April 2014)
Time of manufacture: e.g. 1245
Identification of manufacturing site: MADE IN WA BY ACU-TECH
Extrusion Line No: e.g. L3
The standard number: AS/NZS 4130
ApprovalMark Licence: - AMI 74541
WaterMark Licence: WMKA 22040
Special Application information: e.g. RECYCLED WATER - DO NOT DRINK or SEWAGE
Example PE Pressure Pipe
ACU-WATER PBS18011006 S1 DN180 PN16 SDR11 PE100 AS/NZS 4130 WMKA 22040
AMI 74541 MADE IN WA BY ACU-TECH (08) 9238 8000 140401 1245 L3
9 PACKAGING AND TRANSPORTATION
Acu-Tech advises that transport, handling and storage as set out in AS/NZS 2033 is
recommended. Acu-Tech has documented packaging and delivery procedures for
transporting pipes of various sizes from their plant. Pipe is packaged using timber bases
and scalloped slats between each row, as well as strapping to minimise movement during
transport.
Agencies should ensure pipe is inspected when delivered to site to see that there has
been no transport damage caused by movement and abrasion or serious distortion caused
by excessive tightening of holding straps.
Pipes are delivered by road transport and delivered direct ly to site, unless advised
otherwise by customers.
The Plastics Industry Pipe Association also provides technical guidelines for Packaging,
Handling and storage of Polyethylene pipe and fittings in POP005 Packaging, Handling,
and Storage of Polyethylene Pipes and Fittings.
Copies of these documents can be downloaded from the PIPA website www.pipa.com.au.
10 PRODUCT WARRANTY
The products are covered by the normal commercial and legal requirements of the
Competition and Consumer Act 2010 (Cth), which covers manufacture to the relevant
standard. Details of Acu-Tech Piping Systems warranty is included in their terms and
conditions of sale.
11 WATER AGENCY EXPERIENCE WITH THE PRODUCT OR FIELD TESTING
REPORT
At the time of writing there is no field report available on the installation of Maxiplast PE
pipes. However, PE pipe is becoming a common use pipe material and it is expected that
little would be learned from a field test report. Maxiplast PE100 pipe has been used
successfully in a number of projects over the past 5 years. Examples of some recent
installations include the following:
(a) 10,000 m of DN 200 Acu-Water PN12.5 SDR 13.6 in 20m lengths for a Western
Australian Water Corporation project at Dwellingup installed by DM Civil.
WSAA Product Appraisal 14/02 11
COPYRIGHT
(b) 2,000m of DN560 Acu-Black PN16 SDR11 for the Western Australian Water
Corporation Esperence Port Access Corridor project installed by John Holland.
Both installation contractors reported a high level of quality and service.
(c) Water Corporation (Western Australia) has recently issued an approval certi ficate for
the range of Acu-Tech PE100 pipe for PN1 2.5, PN 16 and PN 20 in sizes from DN
25 to DN 630.
12 LIFE EXPECTANCY
Based on the documented conformance to the nominated standards and the industry
material operational experience, PE pipe has been rated „A‟ – Life expectancy in excess of
100 years before major rehabilitation. This rating is only a general guide to life expectancy
and may increase or decrease as a result of the quality of installation, system operating
conditions, operating environment and other geographical and site specific factors. Using
modern rehabilitation techniques, pipeline systems can be successfully maintained and
operated indefinitely provided the pipe and other structures do not collapse.
13 DISCLAIMER
This Product Appraisal Report (Report) is issued by the Water Services Association of
Australia Limited on the understanding that:
This Report applies to the product(s) as submitted. Any changes to the product(s) either
minor or major shall void this Report.
To maintain the recommendations of this Report any such changes shall be detailed and
notified to the Product Appraisal Manager for consideration and review of the Report and
appropriate action. Appraisals and their recommendations will be the subject of continuous
review dependent upon the satisfactory performance of products.
WSAA reserves the right to undertake random audits of product manufacture and
installation. Where products fail to maintain appraised performance requirements the
appraisal and its recommendations may be modified and reissued. Appraisal reports will
be reviewed and reissued at regular intervals not exceeding five (5) years.
The following information explains a number of very important limits on your ability to rely
on the information in this Report. Please read it carefully and take it into account when
considering the contents of this Report.
Any enquiries regarding this report should be directed to the Program Manager, Carl
Radford, Phone: 03 8605 7601 email [email protected].
13.1 Issue of Report
This Report has been published and/or prepared by the Water Services Association of
Australia Limited and nominated Project Manager and peer group of technical specialists
(the Publishers).
The Report has been prepared for use within Australia only by technical specialists that
have expertise in the function of products such as those appraised in the Report (the
Recipients).
By accepting this Report, the Recipient acknowledges and represents to the Publisher (s)
and each person involved in the preparation of the Report that the Recipient has
understood and accepted the terms of this Disclaimer.
13.2 Limits on Reliance on Information and Recommendations
13.2.1 Disclaimer of liability
Neither the Publisher(s) nor any person involved in the preparation of the Report accept(s)
any liability for any loss or damage suffered by any person however caused (including
WSAA Product Appraisal 14/02 12
COPYRIGHT
negligence or the omission by any person to do anything) relating in any way to the Report
or the product appraisal criteria underlying it. This includes (without limitation) any liability
for any recommendation or information in the Report or any errors or omissions.
13.2.2 Need for independent assessment
The information and any recommendation contained (expressly or by implication) in this
Report are provided in good faith. However, you should treat the information as indicative
only. You should not rely on that information or any such recommendation except to the
extent that you reach an agreement to the contrary with the Publisher(s).
This Report does not contain all information that a person might require for the purposes
of assessing any product discussed or appraised within it (Product). The product appraisal
criteria used in preparing this Report may not address all relevant aspects of the Product.
Recipients should seek independent evidence of any matter which is material to their
decisions in connection with an assessment of the Product and consult their own advisers
for any technical information required. Any decision to use the Product should take into
account the reliability of that independent evidence obtained by the Recipient regarding
the Product.
Recipients should also independently verify and assess the appropriateness of any
recommendation in the Report, especially given that any recommendation will not take into
account a Recipient‟s particular needs or circumstances.
WSAA has not evaluated the extent of the product liability and professional indemnify
insurance that the provider of the product maintains. Recipients should ensure that they
evaluate the allocation of liability for product defects and any professional advice obtained
in relation to the product or its specification including the requirements for product liability
and professional indemnity insurance.
13.3 No Updating
Neither the Publisher(s) nor any person involved in the preparation of this Report [has]
[have] any obligation to notify you of any change in the information contained in this
Report or of any new information concerning the Publisher(s) or the Product or any other
matter.
13.4 No Warranty
The Publisher(s) do[es] not, in any way, warrant that steps have been taken to verify or
audit the accuracy or completeness of the information in this Report, or the accuracy,
completeness or reasonableness of any recommendation in this Report.
WSAA Product Appraisal 14/02 13
COPYRIGHT
APPENDIX A - QUALITY CERTIFICATIONS
TABLE A1 BT FAMILY TRUST T/A MAXIPLAST MANAGEMENT SYSTEM
Quality Systems Standard ISO 9001:2008
Certification licence no. QMS 75367
Certifying agency Approval Mark International
First date of certification 16 November 2013
Current date of certification 16 November 2013
Expiry date of certification 16 November 2015
TABLE A2 BT FAMILY TRUST T/A MAXIPLAST PRODUCT CERTIFICATION
Product Standard/Spec AS/NZS 4130:2009
Certificate No. AMI 74541
Certifying agency Approval Mark International
First date of certification 5 December 2013
Current date of certification 5 December 2013
Expiry date of certification 5 December 2018
TABLE A3 MORREN FAMILY TRUST T/A ACU-TECH PIPING SYSTEMS
MANAGEMENT SYSTEM
Quality Systems Standard ISO 9001:2008
Certification licence no. QEC 29280
Certifying agency SAI-Global
First date of certification 17 February 2012
Current date of certification 25 March 2013
Expiry date of certification 16 February 2015
WSAA Product Appraisal 14/02 14
COPYRIGHT
WSAA Product Appraisal 14/02 15
COPYRIGHT
WSAA Product Appraisal 14/02 16
COPYRIGHT
WSAA Product Appraisal 14/02 17
COPYRIGHT
WSAA Product Appraisal 14/02 18
COPYRIGHT
WSAA Product Appraisal 14/02 19
COPYRIGHT
APPENDIX B - WSAA PRODUCT SPECIFICATION
WSAA Product Appraisal 14/02 20
COPYRIGHT
WSAA Product Appraisal 14/02 21
COPYRIGHT
APPENDIX C - SUPPLIER CONTACTS
Acu-Tech Piping Systems – Manufacturing, Sales and Distribution
Address
119 Kelvin Road
Maddington WA 6109
PO Box 103
Maddington WA 6989
Contact Person Caleb Morren
Phone 08 9238 8000
Fax 08 9238 8800
Email [email protected]
Acu-Tech Piping Systems – Melbourne Depot
Address Suite 3 47 Allied Drive
Tullamarine Vic 3043
Contact
Phone
Ralph Morren
03 9338 0300
Fax 03 9338 0600
Email [email protected]
WSAA Product Appraisal 14/02 22
COPYRIGHT
Melbourne Office
Level 8, 401 Docklands Drive Docklands VIC 3008
Phone: (03) 8605 7666 Fax: (03) 8605 7612 Sydney Office
Level 11, 39 Martin Place
Sydney NSW 2000
GPO Box 915
Sydney NSW 2001
Phone: (02) 9221 5966 Fax: (02 9221 5977
www.wsaa.asn.au