Getting Started Guide v1.1 Included in documentation pack: Getting Started Guide • Warranty • Installation Instructions • Quick Start Programming Guide • Flow Reference Guide • Troubleshooting Site Profile Worksheets Quick Reference Guide Activate your WeatherTRAK Pro3 Pre-activate to expedite at www.weathertrak.com/activate or call (800) 362-8774

Transcript of Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note:...

Page 1: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

Getting Started Guide v1.1

Included in documentation pack:Getting Started Guide •Warranty •InstallationInstructions •QuickStartProgrammingGuide •FlowReferenceGuide •TroubleshootingSiteProfileWorksheetsQuickReferenceGuide

Activate your WeatherTRAK Pro3Pre-activate to expedite at www.weathertrak.com/activateor call (800) 362-8774

Page 2: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Warranty

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3W0513 2 800.362.8774 • hydropoint.com

Our Promise to You

WeatherTRAK Product Series WarrantyHydroPointDataSystemsInc.warrantstothepurchaserofitsWeath-erTRAKproducts,whenshipped in itsoriginalcarton that theywillbefreefromdefectsinmaterialsandworkmanshipforthetimepe-riodset forthbelow. Duringthewarrantyperiod,HydroPointDataSystems,Inc.will,atitsoption,eitherrepairthedefectorreplacethedefectiveproductorpartthereofatnochargetothepurchaser forpartsduringthewarrantyperiod.

The WeatherTRAK ET Pro3 series has a five (5) year warranty from date of purchase.Thiswarrantydoesnotapplytoanyproductwhichhasbeendam-aged, defaced, subjected tomisuse, abnormal service or handling(includingshippingdamage),orwhichhasbeenalteredindesignorconstruction.

Thiswarrantydoesnotcoversurfacediscolorationonstainlesssteelenclosures. Surfacediscolorationcanoccur fromavarietyofenvi-ronmentalconditionsoutsideofHydroPoint’scontrolsuchaswind-blownsoils,waterquality,andcontaminants.

Thewarrantydescribedaboveisinadditiontowhateverimpliedwar-rantymaybegrantedtopurchaserby law. (All impliedwarranties,includingthewarrantyofmechantabilityandfitforuse,arelimitedtotheperiod(s)fromdateofpurchasesetforthabove).

Neithersalespersonnelofthesellernoranyotherpersonisautho-rized tomakeanywarrantiesother than thosedescribedabove,ortoextendthedurationofanywarrantiesbeyondthetimeperiodde-scribedherein.

Thewarrantydescribedabove shallbe the soleandexclusivewar-rantygrantedbyHydroPointDataSystems,Inc.andshallbethesoleandexclusiveremedyavailabletothepurchaser.

Correctionof defects, in themanner andperiodof timedescribedherein, shall constitute complete fulfillmentof all liabilities and re-sponsibilities of HydroPoint Data Systems, Inc. to the purchaserwith respect to theproduct,andshallconstitute full satisfactionofallclaims,whetherbasedoncontract,negligence,strictlyliabilityorotherwise.

InnoeventshallHydroPointDataSystems,Inc.,beliableorinanywayresponsible, foranydamagesordefects intheproductwhichwerecausedbyrepairsorattemptedrepairsperformedbyanyoneotherthanHydroPointDataSystems,Inc.

NorshallHydroPointDataSystems, Inc.,be liableor inanyway re-sponsibleforanyincidentalorconsequentialeconomicorpropertydamage.Somestatesdonotallowtheexclusionofincidentalorcon-sequentialdamages,sotheaboveexclusionmaynotapplytoyou.

Thiswarrantydoesnotapplytoimproperinstallationorgrounding,acts of God, such as lightning strikes and/or electrical line powersurges,floods,earthquakes,hurricanes,tornados,vandalism,verminsuchasslugs,ants,rodentsetc.,orimproperelectricalconnections.

Warranty Service ProceduresInorder toenforce the rightsunder this limitedwarranty, thepur-chasermustnotifyHydroPointDataSystems,Inc.,ofawarrantyclaimby contacting (800) 362-8774. At that time, the purchaserwill beaskedtoprovidedatedproofoforiginalpurchase.Acceptableformsofthisshallbeaphotocopyorscannedimageofthedatedoriginalinvoice faxedoremailed toHydroPointDataSystems, Inc.Thepur-chaserwillalsoneedtoprovideafulldescriptionofthetypeofprob-lemoccurring,acontactname,addressandtelephonenumberand/oremail.Ifrequested,purchasermustreturnthedefectiveproductattheirownexpense.

Table of Contents

Warranty ........................................................................... 2

Installation Instructions ................................................... 3GettingtoknowWeatherTRAK ........................................4WallInstallation .....................................................................6Activation ................................................................................ 10Programming ......................................................................... 10

Quick Start Programming Guide ..................................... 11ActivationorHelp ................................................................ 12Programming ......................................................................... 12MaintenanceTips .................................................................14

Flow Reference Guide ....................................................... 17Function ...................................................................................18Setup .........................................................................................18LearningStationFlow ......................................................... 20

Troubleshooting Guide .................................................... 23WeatherTRAKETPro3CentralAlerts .............................24DefinitionofAlerts ...............................................................25

HydroPoint Data Systems, Inc.

1720 Corporate Circle Tel (800) 362-8774Petaluma, CA 94954 Fax (707) 769-9695 [email protected] hydropoint.com

Page 3: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

hydropoint.com

WeatherTRAK ET Pro3

Installation Instructions

Page 4: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 4 800.362.8774 • hydropoint.com

Getting to Know WeatherTRAK ET Pro3

Inthissection,controllernavigationandnewhardwarefeaturesareidentified.

NavigationTheuserinterfaceincorporatesfivemainfunctions:

1. Thedisplay2. Themenubuttons3. Theleftv andrightlarrowbuttons4. Theplusgandminus… buttons5. The*button

Figure 1 Controller Front Panel

Thecontrollerusesa5-line,24-characterdisplay.Thescreencon-trastcanbeadjustedintheSETUPmenuforlowandbrightlightconditions.Theupperlinedisplaysthesub-functionsofanyoneofthe4mainmenubuttonsasshowninFigure1.Thesecondorlowerlinecommonlydisplayschoicesofvalueswithineachsub-function.Thethirdlineiscommonlyusedtodisplayalertsoridentifyabbre-viationsofAlerts.

Pushingtheleftorrightarrowbuttonsallowsyoutoscrollthroughallofthesub-functionswithinamenu.Pushingtheplusandminusbuttonsallowsyoutoselectchoicesforeachsub-function.Press-ingandholdingthe*buttoninsomelimitedsub-menuswithintheSETUP,STATIONS,FLOWandMANUALmenuswilldisplayadditionalinformation.IntheCOPYmenuthe*buttonexecutesthe“copy”function.

Controller Hardware TheWeatherTRAKETPro3seriesdeliversuniquehardwarefeaturestosimplifyinstallation,fielddiagnosticsandtroubleshooting:• Interchangeabletransformerandgroundluglocation• Easilyremovablecommandmodule—withouttheneedfor

handtools.• ModularStationhardwarekeystoincreaseordecreasestation

count.

Station Output DesignThenumericalvaluescorrespondtotheFigure2linedrawingofthestationoutputboardsforfasterrecognition.

1. Heavy-dutypush-intypeterminalblocks;twoinputspersta-tionrequirenotoolstoconnectordisconnectfieldwire.(Thismakesiteasiertoteststationoutputvoltageorresistancetotroubleshootwiringissues).Terminalblocksareononehori-zontalplaneforfasterinstallationwithmultiplevalvecommonwireterminations.Apumpstartcanbeassignedasanystationoutput.

2. Dedicatedflowsensorinputsandseparatemastervalveoutput.

3. CorrespondingstationoutputgreenLED’sforconfirmationofvalveoperationduringscheduledirrigation,manualoperationorvalvefieldwireintegritytesting.AblueLEDdesignatesamastervalveoutputwhenprogrammed.

4. Removablerainsensorand24-VACterminalblockforfasterfieldwireconnection.

5. Stationmodularitythatprovides6-stationcountflexibilitybysimplyinsertingahardwarekeytoactivateadditionalstations.AdditionalkeyscanbepurchasedfromHydroPointoryourlocalHydroPointdistributor.

6. Replaceable3.0ampslo-blowfuseprotectiontoprotectthetransformerfromfieldwireshorts.

7. TroubleshootingyellowandgreenLED’sonthestationinput/outputboardsindicate24-and5-Voltpowerrespectively confirmingpropervoltagehasreachedoneorbothstationoutputboards.

8. DirectremotecompatibilitywitheitheraRainMaster™ProMaxUAwithEX32cableassemblyorTRC™CommanderorSidekickserieshand-heldremotes

Note:Smallmechanicalfootprintmakesiteasytoinstallandprovidesawiderangeofapplicationsparticularlywherespaceislimited.

Page 5: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 5 800.362.8774 • hydropoint.com

1 2 3 4 5 6 7 8 9 10 11 12 MV1 VC

13 14 15 16 17 18 19 20 21 22 23 24 VCFL1

25 26 27 28 29 30 31 32 33 34 35 36 MV1 VC

37 38 39 40 41 42 43 44 45 46 47 48 VCFL2

!

@

#

$

%^

&

*

Figure 2 Station Output Board Design

Note:Stationoutputboards12-24and25-48areidentical,butdonotsupporttworainsensors.Terminatetheflowsensorandrainsensorwiresinthe12-24stationoutputboardonly.

Interchangeable Transformer TheWeatherTRAKETPro3shipswiththetransformerontherightsideoftheenclosure.Thisenclosuredesignallowsthetransformertobemovedtotheleftsidetoaccommodateelectricalconnectionsasneeded.Themountingbracketisinterchangeabletosimplifyrelocatingthetransformertotheleftsidewhennecessary.

Figure 3 Interchangeable Transformer and Ground Lug

Note:Ifthetransformerisre-locatedtotheleftside,thenrelo-catethegroundlugtotherightsideasshowninFigure3.

Center Drill Points for Rain Sensor MountingThebottomleftandrightoutersidesoftheenclosurehavetwosetsofdrillingcenterpoints.ThesedrillingpointsareforenclosuremountingforspecificIrritrolorTorowirelessorwiredrainorrain/freezesensors.Two(2-qty)self-tappingstainlesssteelscrewsaretapedtotheinsideoftheenclosuretomountarainsensorreceiverwhenneeded.

Figure 4 Drill Points for Rain Switch Mounting

Note:Mounttherainsensorreceiverontheoppositesideofthetransformerlocationtoavoidreceptionissuesforwirelessmodels.

Removable Command Module Thefaceplateorcommandmodulecanbeeasilyremovedorsliddownintoalowerpositionbylooseningthecaptivescrewsbyhand.Removingthecommandmoduleprovidesaccesstotherainswitchinputand24-VACsource.

Note:Ifpanelremovalisnecessary,supportitwithonehand,thendisconnectthecableswiththeotherhandandsetit asidecarefully.

Figure 5 Removable Command Module

Page 6: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 6 800.362.8774 • hydropoint.com

Station KeysTheWeatherTRAKETPro3incorporatesstationcountmodularitybyusingstationkeys.Thestationinput/outputboardsareavailableintwoconfigurations,uptoeither12to24stationsor12to48sta-tions.Toincreasethestationcountfrom12to18stationsorhigher,insertastationkeyintothestationoutputboardfromlefttoright(seeFigure6).Thestationkeywillilluminatewhenactivated.Thecontrollerwillautomaticallydiscovertheexpandedstationcountwithin30seconds.

Figure 6 Station Keys

Toprogramadditionalstations:• Increase“MaxActiveStations”intheSETUPmenu.Additional

stationscanbeprogrammedfromthecontrollerorremotelyviawww.weathertrak.net.

• Toincreasetheoverallnumberofstationsabove24,addanadditionalstationexpansionboardwiththecorrespondingsta-tionkeys.ContactHydroPointoryourlocaldistributorforthisservicekit.

Controller Electrical Specifications• TransformerSize:3.0amp,80VA,ULlisted• InputPower:120VAC(60Hz)or220VAC(60Hz)• StationOutputSpecifications:

• 24VAC(60Hz)• 1.0amps(1000milliamps)max.perstationoutput/pump

output • 1.0amps(1.0milliamps)maxmastervalveoutput• 3.0ampsmaximumallowableload

Wall Installation

Note:AvoidpotentialelectricshockbyconfirmingtheACpoweris“off”beforestartingthiswork.

Wall Mounting InstructionsLocatethe2mountingholesonthebackoftheenclosure.Thetwouppermountingholesarekeyholes.Thisdesignallowsthetwoupperfastenerstobeinstalledfirst.Theenclosureisthenslippedoverandpusheddowntocompletetheinstallation(seeFigure7).Usetheenclosedblue-coloredpapertemplatetolocatetheseholesaccurately.Typicalmountingheightforawall-mountenclosureisbetween41”and48”aboveafinishedsurface.

Figure 7 Example of Wall Mount Drilling Template

Athirdmountingholecanbefoundinthecenteroftheenclosurebelowthestationinput/outputboard.

Beforedrilling,verifythatthecontrollerislevelandverticallystraightbeforeinstalling.

Step 1. Removetheouterdoortogainbetteraccesstotheinterioroftheenclosurebyslidingitupwards,thenplaceitinalocation to prevent damage.

Step 2. Markanddrillnewmountingholesusingtheblue-coloredpapertemplate,thendrillappropriatelysizedholeswithahammer-drillasneeded.Useplasticinsertsandmountingscrews(tapedtothecontrollerwiththeenclosurekeys)tosecurethecontroller.

Step 3. Hangtheenclosureonthesefastenersandverifytheen-closureismountedlevelbothverticallyandhorizontally.

Step4. Locatethethirdcentermountingholeandinsertthelastfastener.Tightenallfastenerstotheenclosuretosecuretotheverticalsurface.

Page 7: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 7 800.362.8774 • hydropoint.com

Connecting the Controller to AC PowerThefollowingwiringdiagramsandinstructionsindicateACpowerconnectionstobothwall-mountandpedestalstylecontrollers.

TheWeatherTRAKETPro3seriescontrollerincorporatesadualvolt-agepowersupplyforawiderangeofcommercialapplications.Thecontrollercanbeconnectedtoasinglephase120Vorsinglephase220Vsource.

Theinputsideofthetransformerhas5color-codedconductors.Alabelisattachedtothetransformerbodywithidentificationforeachconductor.Twooftheconductors(specificto220Vconnections)havebeenterminatedwithwirenuts,shortenedandtiedtogetherwithazip-tietoavoidconfusionfor120Vinstallations.

Note:BeforemakingaconnectiontoyourWeatherTRAKETPro3seriescontroller,disconnectthepowertoavoidelectricshock.Thisinstallationshouldbemadebyaqualifiedelectri-cianandshouldmeetstateandlocalelectricalcodes.

Step 1. Confirmthecontrollerhasbeensecurelyfastenedtoaflat,verticalsurfacebeforestartingthiswork.

Step 2. Opentheenclosuredoorandlocatethetransformermountedtothechassis.Threadanapprovedweatherproofplasticorgalvanizedmetaljunctionboxontothe1/2”nippleandsecurewithaconduitlocknut.

Step 3. Connectapprovedconduittotheundersideofthejunc-tionbox.

Step4. Pulltherequirednumberofconductorsandterminatetheminthejunctionboxwithsufficientlengthsothatwirenutconnectionscanbemade.

Step5. Removeapproximately1/2”ofthewireinsulationoftheconductoranduseanappropriatelysizedwirenutbasedonthenumberofwireconnectionsbeingmade.Adheretolocalandstateelectricalcodes.

Step6. Thegroundwireshouldbeterminatedwithanappro-priatelysizedeyelet(includedongroundingstud)andsecuredwithanutwiththeintegralstarwasherlocatedwithinthejunctionbox(seeFigure8).

Figure 8 Typical 120 Volt Wiring Diagram

Note:Blueandbrownwiresaretiedoffwithaziptieandwirenuts.

Note:For120Vwireapplications,connectthefollowingconductorsfromtheprimarysideofthetransformertowiringfromanapprovedelectricalsource(seeFigure8).Theunusedblueandbrownwiresarecutshortandterminatedwitha wirenut.

Note:For220V,single-phaseapplicationsconnectthefollowingconductorsfromtheprimarysideofthetransformertowiringfromanapprovedelectricalsource(seeFigure9).

!

Page 8: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 8 800.362.8774 • hydropoint.com

Figure 9 Typical 220 Volt Wiring Diagram

Note:Secureeachgroundwirewithitsownindividuallockingnutandintegralstarwasher.Theunusedblackandbrownwiresshouldbeterminatedwithawirenutseparately.

Rain Switch Installation TheWeatherTRAKETPro3seriescontrolleriscompatiblewiththefollowingmanufacturersofnormallyclosedwiredorwirelessrainorrain/freezeswitches:

• ToroTMwiredandwirelessrainswitches• IrritrolTMwiredandwirelessrainswitches• Hunter Mini-ClikTM

• HunterwirelessRain-ClikTMrainswitches• RainBird®WR2wirelessrainswitches

TheETPro3seriesisnot compatible withthefollowingrainswitches:

• RainBirdRainCheckTMseries• RainBirdTippingBucketTMmodels• RainMasterTippingBucketTMmodels

• WaterConservationServices’RainGuardTMseries

!

Note:Whenawirelessrainswitchisusedwithametalen-closure,installtherainsensorreceiveroutsidetheenclosuretoensurereceptionfromaremotelymountedrainswitchtransmitter.

Irritrol Wireless Rain Switch InstallationStep 1: Mounttherainswitchreceiverwhereitcanbeeasily

accessedandobserved.

Note:Donotinstallawirelessrainsensor withinmetalenclosureswheresignalstrength isdiminished.

Step 2: Forwall-mountinstallations,routethereceiverwiresthroughthebottomoftheenclosureintotheinterioroftheenclosure.Deburranyfielddrilledthroughholesandinserta¼”insidediameterrubbergrommettoprotectfieldwiring.Addasmallamountofsiliconesealantwherethesensorwireentersthegrommetforaddedprotection.Avoidshortingwiresfromanopenthru-holewithoutagrommet.Ashortedwirecancausepermanentdamagetothecontrollerelectron-ics,anissuenotcoveredunderwarranty.

Step 3: Locatetherainsensorinputterminalblockintheupper-leftcornerofthe24-stationinput/outputboard.Thisterminalblockisdesignedtoberemov-abletofacilitatefasterconnectionofrainsensorwir-ing.Toremove,simplywiggletheterminalblocksidetoside.Remove the rain switch wire jumper before installing the rain sensor wire.(SeeFigure10).

Figure 10 Rain Switch Terminal Block with Loop

Step4: Removeapproximately3/8”ofwireinsulationtoexposethesolidorstrandedconductor.

Step5: Confirmtheleverofthescrewlessterminalisintheuporunlockedposition.Inserttheexposedwireandpresstheleverdownwardtolock.Confirmcontactbygentlypullingdownontheinsertedwire.

Page 9: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 9 800.362.8774 • hydropoint.com

Step6: Connecttheredwirestothe24-VACterminalstoredcoloredterminals.Theseterminalsarenotpolarized;eitherwirecanbeinsertedintoeitherofthetwofarleftterminalpositions.

Step7: InsertthewhitewireintothewhiteterminalandthebrowncoloredwireintoblackterminalasshowninFigure11.

Note:Confirmtheleverhasnotclampeddownonthewireinsulationwhichcanresultinelectricalcontinuityandoperationoftherainswitch.

24 Rain Rain Flow 24 Input Input Sensor VAC RS1 RS2

Figure 11 Irritrol Wireless Rain Switch Series

Step8: Locatetherainswitchtransmitterwithinthemanu-facturer’srecommendedrange.Locatethetransmit-terwhereitwillreceiverainfallwithoutobstruction.Confirmcommunicationtothereceiverbeforemountingpermanently.

Step9: Testtherainsensorfunctionbypressingthetestswitchontopofthetransmitterforabriefperiodoftime.Confirmthecontrollerdisplays“RainSwitch”intheRUNmenuwhenthetestswitchisdepressed.

Note:Forothercompatiblerainswitchwiringdiagrams,pleasereadthemanufacturer’sinstallationinstructionsfornormallyclosedrainswitches.

Connecting a Flow SensorTheWeatherTRAKETPro3seriesiscompatiblewithDataIndustrial(BadgerMeter)IR220series,CreativeSensorTechnologyandNeta-fim(usingreedswitchregisters)irrigationflowsensors.

To connect a flow meter:Step 1: Locatethesix-positionterminalblockinthemiddle

ofthefirst12-stationoutputboardandlocatetwoinputsforflowsensingonthefarright.Thesearelabeled“FL1”/”VC”andreflectthecoloroftherecom-mendedshieldedflowsensorwire(seeFigure12).

Figure 12 Flow Sensor Input

Step 2: Remove3/8”ofwireinsulationandplaceintotheap-propriateterminalblockbyconnectingtheredwireto“FL1”(orthe“+”terminal)andblackwiretoVC(orthe“-“terminal).

Step 3: Closeorpushdowntheterminalblocklever.

Step4: ConsulttheFlowReferenceGuideinthispacketforinstructionsonhowtosetupflow.

Connecting a Hand-Held RemoteWeatherTRAKETPro3seriescontrollerscomestandardwithhand-heldremotecapability.Compatibilityissimplyplugandplaywithnoadditionalwiring,software,activationorprogrammingrequired.TheWeatherTRAKETPro3seriesisdirectlycompatiblewiththefol-lowinghand-heldremotes:

• RainMasterTM PROMAX-UA with 32 EX extension cable (soldseparately)

• TRCTM-TRCommanderorSidekickSeries(soldseparately)

Note:TheseproductsareavailablethroughlocaldistributorsandarenotpartoftheWeatherTRAKproductline.

Bothhand-heldremoteproductsareintendedforportableuseandrequirethatthetransceiverwithantennabelocatedoutsidetheenclosuretoensureconsistentoperation.ThestationLED’swillslightlyilluminatewhenthehand-heldreceiverispluggedin.AblueLEDwillilluminatewhenamastervalveisactivatedfromtheremoteindicatingithasbeenactivated.

Page 10: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Installation Instructions

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513 10 800.362.8774 • hydropoint.com

Note:Ifpermanentmountingofthetransceiverisrequired,installtheantennaoutsidetheenclosure.

BoththeRainMasterandTRCremotecablescanbepluggedintoeitheroneoftheverticallyoriented32-pinconnectorsoneitherstationoutputboard,(seeFigure13).Theconnectorscorrespondtostations1-24orstations25-48asneeded.

Note:Forstations25-48,youmustenterstation1for25,2for26,…24for48usingtheremoteinterface.

Figure 13 Hand-held Remote Connectors

Note:Hand-heldremotekitscanbepurchasedthroughyourlocalirrigationdistributor.

Note:Functionalityofeitherremoteislimitedtomanual on/off,stationupordownandmastervalveon/off.

Followthehand-heldremotemanufacturer’sprogrammingsequencewhenanormallyopenmastervalveisinuse.AnotheralternativeistousetheMaintenanceTimeoutfeaturefoundintheADVANCEDmenutoopenthemastervalvein½hourincrementsfrom½hourto8hours.

Manual Valve TestToensureallfieldwiringisproperlyconnectedandallstationsareoperatingproperlyconductafieldwireintegritytest.

Step 1. PressthemainmenubuttontoMANUAL.

Step 2. Presstheminusbuttonuntilthe“ValveTest”screenap-pears.

Step 3. Presstherightarrowbuttonuntilthefollowingscreenappears:

RUNVALVETEST—RTVT:OFF

00SH00NCFaults

Step4. PresstheSELECTbutton,thenpressthe“*”buttontostartthetest.Itwilltakeabout15secondstoverifycontinuitytoallstationsandthemastervalve.

Step5. Ifanyfieldwiringissuesexist,theywillbeidentifiedasa“Fault”.Avalvefaultcouldbe“SH”(ValveShort)fromafailingsolenoidOC(overcurrent)fromvalvesdrawingmorethan1000mAoran“NC”(ValveNo-Connectoropen)reflectingabrokenwireorwirethatisnotmakinggoodcontactinthecorrespondingstationterminal.

Activation

Inordertoreceivedailyweatherupdates,yourcontrollermustbeactivated.Toactivate,callHydroPointCustomerServiceat(800)362-8774.

For a faster call, complete the blue activation card inside the

controller before calling HydroPoint Customer Service.

Programming

RefertothelaminatedQuickStartProgrammingGuideforprogram-minginstructionsinbothEnglishandSpanish.Freeonlinetrainingisavailableat:http://hydropoint.com/training/

Visithydropoint.comorsupport@hydropoint.comtoaccessandprintadditionalcopiesofthisInstallationGuide.

Note:RainMasterTMisaregisteredtrademarkofRainMasterIrrigation;PROMAXTMisregisteredproductofRainMasterIrrigation;TRCTMisaregisteredtrademarkofRemoteControlTechnologies.

Page 11: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Quick Start Programming Guide

hydropoint.com

WeatherTRAK ET Pro3

Quick StartProgramming Guide

Page 12: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Quick Start Programming Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3QSPG0513 12 800.362.8774 • hydropoint.com

Date: Year,Month,Day

Time: Hour(confirmamorpm),minutes

Time Zone:Selectyourlocaltimezone

Auto Daylight Savings:Automaticallyupdatescontrollertwiceayear,unlessyoupressthebuttonto“No.”

Maximum Active Stations:Numberofstationsphysicallywiredintothecontroller.

Stack or Overlap: WhenStackisselected,allprogramsoperateoneafteranother. Thestarttimeandwaterwindowforallpro-gramsisassignedtoProgramA.WhenOverlapisselected,eachprogramcanhaveitsownstarttimeandwaterwindow.SeetheOwnersManualformoredetail.

The following SETUP functions are optional:Master Valve: SelectthetypeofMasterValveifused.

Note:ItisimportanttoselectNoneifamastervalvedoesnotexist.SelectingNormallyOpenorNormallyClosedwhenyoudonothaveamastervalvemaycauseaValvealertthatcanprevent irrigation.

Assign Pump Start Output:Anystationoutputmaybeselected.Ifapumpstartisnotrequired,leavethissettingasNotAssigned.

Runtime Valve Test: Default setting is“Yes”. See theOwner’sManualformoredetails.

Max Backup ET: Representstheworst-caseweeklyET foryourareaforthemonthofJuly.Ifyouarenotsurewhatthisnumbershouldbe,callourCustomerService800numberforhelp.

Days / TimesInthismenuastarttime,waterwindowandawaterdaymodecanbeassignedtooneoffouravailableprogramsA-D.Ifapumpstarthasbeenassignedasastationoutput,anyoneofthreeprogramscanbeexcludedfromapumpstart.

Note:CheckforSTACKorOVERLAP(SeeSETUPforStackorOverlap.):IfStackisset;programsB,CandDwillhavethesamestarttimeasprogramA.ProgramswillrunsequentiallystartingwithprogramA.IfOverlapisset,differentstarttimesmaybesetforeachprogram.

Exclude a Program from a Pump Start (only when assigned)Anyoneofthreeprogramscanbeexcludedfromapumpstartwhenastationoutputhasbeenassignedasapumpstart.Thefactoryde-fault isallprogramsareassignedtoapumpstartunlessotherwiseselected. This featuremightbeusedwhendripemittersand rotorusethesamemainlinebutonlyonesprinklertypeneedstheaddeddeliverypressure.

Set Start Times and Water WindowsPresstheDAYS/TIMESMenubutton.PresstheplusorminusbuttontoselectprogramA,B,CorD.PresstherightorleftarrowbuttontoSETSTARTS/WINDOWS.PresstheSELECTbuttontoedit1stSTART/WINDOW.Pressthearrowandplusorminusbuttoninsequenceto

Activation or Help

Call Customer Service 1-800-362-8774

ThecontrollermustbeactivatedtoreceivedailyETinformation(localweatherinformation).Tospeedupactivation,completetheActivationcardincludedwiththemanualsandotherdocumenta-tionbeforecallingCustomerService.

CONTROLLERMUSTBEACTIVATEDTOUSE AUTOMATEDBYWEATHERTRAKORUSERWITHET.

Programming

Setup

The following SETUP functions must be setup for the controller to operate properly. PresstheSETUPMenubutton.Presstheleftorrightarrowbuttonstomovetoeachfunction.Presstheplusorminusbuttonstochangetheunderlinedvalue.

Page 13: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Quick Start Programming Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3QSPG0513 13 800.362.8774 • hydropoint.com

setthestarttimeandthewaterwindow.Ifa2ndstarttimeisneededpresstherightorleftarrowbuttonto2ndSTARTTYPE.Presstheplusorminusbutton to seteitherHighETorOff.Repeat thisprocedureforeachprogramused.1stand2ndstarttimescannotoverlapandthemaximumwaterwindowis24hrs.

Selecting Water Day ModePresstheDAYS/TIMESMenubutton.Presstherightorleftarrowbut-tontoWATERDAYMODE(forProgramA,B,CorD).Presstheplusorminusbuttontoselectoneofthefollowingsevenwaterdaymodes:

Optimized by WeatherTRAK:ETandindividualstationsettingsdeterminewateringdaysautomatically.Presstheplusorminusbuttontoexcludeadayifneeded.

Odd/Even: WatersbasedonOddorEvencalendardays. PresstheplusorminusbuttontoselectOddorEvendays.

Interval:WhenIntervalisselected,presstherightorleftarrowtoWATER DAY INTERVAL. Presstheplusorminusbuttontosetthedayinterval.Dayintervalscanbesetfrom1to30days.

Days of Week: Usesa7-daycalendarSundaythroughSaturday.Presstherightarrowtomovethrougheachdayoftheweek.Presstheplusorminusbuttontoturndaysofforon.(Offdaysshownasadash“—“).

Days of Week by Month:Usesa7-daycalendarSundaythroughSaturdayforeachmonthoftheyear.Presstherightarrowbuttonto JanOKTOWATERON.Press the right arrowbutton tomovethrougheachdayoftheweek.Presstheplusorminusbuttontoturndaysofforon.Presstherightarrowbuttontomovetothenextmonth.Followtheaboveprocedureforeachmonthoftheyear.

Off:WhenOffisselected,thecontrollerwillignoreprogrammedstartsfortheselectedprogramuntiladifferentwater-daymodeisselected.

StationsIndividual stations are assigned to a program (start time(s), waterwindowandwaterdaymode),andstationmode.Therearefoursta-tionmodestoselectfrom:AutomatedbyWeatherTRAK,Userw/ET,UserNoET andOff. Select the stationmodebasedon the typeoflandscapetobeirrigated.

Note:Thesamestationcannotbeassignedtodifferentprograms.

Programming for Existing LandscapesAutomated by WeatherTRAKAutomatically calculates run times, cycle and soaks for each zonebasedonzone-specificattributes.DailyETupdatesthenadjustthecalculatedruntimestoreflectcurrentweatherconditions.Runtimeswillvaryasweatherchanges.

Note:Tonavigatethroughthenextseveralscreens,presstherightarrowbuttontomovetoeachunderlinedheadingandpresstheplusorminusbuttontoselectachoicewithineachfunction.

Select Station:Locatethestationtobeprogrammed.

Select Station Mode: Select AutomatedbyWeatherTRAK.

Note:ToPreviewabbreviatedAutomodestationsettingsforthisspecificstation,pressandholdthe*button.

Select a Program: Assignthestationtoaprogramthathasastarttimeandwaterdaymode.

Use Water Window:Ifthisstationcanirrigateoutsideofthewa-terwindow,select“No”.

Usable Rainfall:Ifastationisunderaroof,heavytreecanopyorsemi-porousroof,selecteither“None”orapercentofrainfallthatisactuallyused.When“None”isselected,thespecificstationwillwaterduringRainPause.

Sprinkler Type: Select 1 of 13 industry-recognized sprinklertypes. Whenasprinklertypeisselected,adefaultprecipitationrateandsprinklerefficiencyvalueisautomaticallyassigned.Bothvaluescanbechangedinthenexttwoscreens ifdifferentthanthedisplayeddefaultrates.

Precipitation Rate: IshowmuchisappliedinInchesperHour.Changing the precip ratewill change run times. Lower Preciprates=highruntimes,HigherPreciprates=lowerruntimes.

Sprinkler Efficiency:Everysprinklerapplieswaterwithaspecificefficiencybasedon itsdesignandperformanceand spacing. Ifheadorrowspacingisstretched,efficiencyisless.(Higher=lesswater;Lower=morewater).

Soil Type:Select1of5soiltypesdeterminedbytheUSDA.

Plant Type: Select1of17planttypesthatbest representsthevalvezonebeingirrigated.

Root Depth:Presstheplusorminusbuttontoselectrootdepth.(Shallowroots=more frequentwatering;deeproots= less fre-quentwatering.)

Microclimate: Select1of4 levelsofsunexposureofthevalvezonebeingirrigated.

Slope: Select1of5slopegradients. Thesteepertheslopethehighernumberofcycleswillbeapplied.

Sprinkler Location on Slope: Select1of5choices identifyingsprinklerlocationsonaslope.

Next Station: Presstherightarrowbuttontogotothenextsta-tionoruseCOPYtoduplicatesettingstolikestations.

Page 14: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Quick Start Programming Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3QSPG0513 14 800.362.8774 • hydropoint.com

Maintenance Tips

Manual WateringStations canbeoperated individuallywith specific run timesor allstationswithoneruntime.PresstheMANUALMenubutton.Select“SpecificStations”or“AllStations”bypressingtheplusorminusbut-ton.

Manual Water Specific Stations: Press the right or left arrowbuttontothefirststationyouwanttowater.Presstheplusormi-nusbuttontotheminutesdesired.Theselectedstationwillstartimmediately. Toaddmorestations,presstherightorleftarrowbuttontothenextstationdesired.

Manual Water All Stations:Presstheplusorminusbuttontothedesiredruntime.Station1willstartimmediately,andallotherac-

tivestationswillfollowsequentiallyforthesameruntime.

Note:TostopastationthatisoperatingmanuallypresstheOFFMenubuttonfor5secondsthenbacktoRUN.

% Adjust - More or Less WaterAdjust Water AmountAdjustsindividualstationsformoreorlesswater.A0%settingmeansthereisnoadjustmentforthatparticularstation.

Pressthe%ADJUSTMenubuttonifvalvezoneistoowetortoodry.Presstheplusorminusbuttontoselectthestationtoadjust in5%incrementsfrom-50%to+25%.

Adjust Day FrequencyIncreasesordecreases thenumberofdaysof theweekper stationwhenwaterisappliedanddoesnotincreasetheamountbeingap-pliedunlessETincreases.A0%settingmeansthereisnoadjustmentforthatparticularstation.

Press theplusorminusbutton toDayFrequency/Depletion. PresstherightorleftarrowbuttontoADJDAYS(MAD).Presstherightorleftbuttontoselectthestationtoadjust.

Note:UsingeitherAdjustfunctionadjustsETorMADwhichwilladjustruntimesorfrequencyofirrigation.

Rain Pause - Suspend IrrigationPause Controller: This feature is useful formajor rain events,scheduledactivitiesoranyothereventwherewateringmustbesuspendedforasetperiodoftime.RainPausestopsallirrigation(exceptmanualwatering). Press the RAIN PAUSEMenu button.Presstheplusorminusbuttontosetthenumberofdaystobepaused(upto200days).RainPausecanbereducedoreliminat-edbyusingpressingtheplusorminusbuttontoremovepauseddays.

User With ETSet run times, number of cycles and the soaks between cycles. ItthenautomaticallyincreasesordecreasesruntimebasedonthedailyweatherinformationdefinedasET.

Select Station: Locatethestationtobeprogrammed.

Select Station Mode:SelectUserw/ET

Select a Program:Assignstationtoaprogram(withastarttime,waterwindowandwaterdaymode).

Use Water Window:Ifthisstationcanirrigateoutsideofthewa-terwindow,select“No”.

Usable Rainfall: Ifastationisunderaroof,heavytreecanopyorsemi-porousroof,selecteither“None”orapercentofrainfallthatisactuallyused.When“None”isselected,thespecificstationwillwaterduringRainPause.

Set Runtime: Setadesiredcycleruntime.

Set Number of Cycles and the Soak Time: Select from 1-20cyclesandSoaktimesfrom0to480minutesin10minuteincre-ments.

Reference ET: Set a reference ET that is appropriate for theschedulejustset.ThenumberyouseeinparenthesisisETforthepastweekandisthevaluetoenterasPart1and2.Alternately,youcansettheprogramyouwouldruninJulyanduseaweeklyreferenceETthatisnormalforyourareainJuly.

Other Stations:Repeatthesestepsforotherstationsassignedtothisstationmode.

Programming for New LandscapesUser No ETUserNoETiscommonlyusedforplantestablishmentperiodswhenoverwateringisrequiredtoestablishnewroots.Runtimes,cycleandsoakperiodsarealluserdefinedinthisstationmode.UserNoETsetsupthesameasUserWithETexceptthereisnoreferenceET.ActivationisnotrequiredforUserNoET.

CopyThisfunctionletsyouquicklycopyallstationsettingsfromanypar-ticularstationtoanyotherstationortoallstations.PresstheCOPYMenubutton.Presstherightorleftarrowbuttontoselectthestationtocopy from. Press theplusorminusbutton to select the stationtocopyto.(“AllStations”isoneofthechoices.)Pushthe(*)buttonuntilCOPYINGisdisplayed.Repeattheprocessforeachstationtobecopied.

Page 15: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Quick Start Programming Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3QSPG0513 15 800.362.8774 • hydropoint.com

Note:The controller counts down the pause days at the Program A Start time. A controller with 1 day pause will start irrigation right after the next Program A start time.

PreviewThismenuPreviewsprogrammingchangesofindividualstationdataorFlowparameters(ifaflowsensorisusedandsetup).

Station DataPress the rightor less arrowbutton to view stationdata. Press therightorleftarrowbuttontochangethestationnumberandtheplusor minus button to view projected water days (based on currentET) inoneweekincrementsfrom1-8weeks.Displayedstationdataincludes run time, cycle and soakperiods, stationmode,%adjust-ments,projectedwaterdaysonaweeklybasis.

Flow DataPresstheplusorminusbuttontoviewFlowData.PresstherightorleftarrowbuttontoviewpreviouslysetupFlowparameters.(Ifaflowsensorissetupandused).

Manual Valve TestManual Valve Test FunctionThisfeatureconfirmswireintegritybetweenthecontrollerandvalvesinthefield.Thistestcanquicklyidentify,onastationbasis,whereanelectricalfaultexists.

Run Manual Valve TestPresstheMANUALMenubutton.PresstherightorleftarrowbuttontoRUNVALVETEST.PresstheplusorminusbuttontochangefromSkiptoView.Pressthe (*)buttontoruntheManualValveTest.Youwillhearthecontrollerbrieflysendasignaltoeverystationincludingthemastervalve.Presstherightorleftarrowbuttontoviewthefirsteightvalves.Press the rightor leftarrowbuttontoviewadditionalstationsingroupsofeight.“?”meansthetesthasnotbeenoperatedand“--“meansthestationdoesnothaveanelectricalfault.Thistestcannotberunifanyvalveisoperating.TheControllerwillidentifya(SH)“Short”(currentdrawexceeding1000mA)or(NC)“NoConnect”reflectingabrokenwire.

Note:ValvealertsmustbeclearedintheALERTmenutoensurestationswilloperate.Failuretoclearanalertcouldsuspendwatering.Ifarelayispresent,thecontrollerwilldisplayan“SH”becausetherelaycannotopenandclosefastenoughforthedurationofthistest.

Viewing Solenoid Current DrawThecontrollerwilldisplaythemilliampdrawofanystationsolenoidinthistest.

Step 1. PressthemainmenubuttontoSETUP.

Step 2. Presstherightarrowbuttonuntilthefollowingscreenappears:

RUNVALVETEST—RTVT:OFF

Skip00SH00NCFaults

Step 3. Presstheminusbuttontochangetheword“Skip”to“View”,thenpressthe“*”buttontostartthetest.Itwilltakeabout15secondstoverifycontinuitytoallstationsandthemastervalve.

Step4. Ifanyfieldwiringissuesexist,theywillbeidentifiedasa“Fault”.Avalvefaultcouldbe“SH”(ValveShort)fromafail-ingsolenoidoran“NC”(ValveNo-Connectoropen)reflect-ingabrokenwireorwirethatisnotmakinggoodcontactinthecorrespondingstationterminal.

System ShutdownThisfeaturecanbefoundintheOFFmenuwhenacatastrophiceventoccurs.Thisfeatureisnotintendedforwinterizationbutwillstopscheduledirrigationuntilemergencyrepairscanbemade.PresstheOFFMenubutton.Presstheplusorminusbuttontolocate“SystemShutdown”.Thecontrollerwillimmediatelystopallsched-uledirrigationandcloseanormallyopenmastervalveuntilresetbypressingthe(*)buttoninthissubmenu.

Page 16: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain
Page 17: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK ET Pro3 Flow Reference Guide

hydropoint.com

WeatherTRAK ET Pro3

Flow Reference Guide

Page 18: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Flow Reference Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3FRG0513 18 800.362.8774 • www.hydropoint.com

Flow Alert Clearing Thisscreenprovidesachoicebetween(a)allowingthecontrollertoautomaticallyclearflowalertsatthebeginningofthescheduledPro-gramAstarttime,or(b)requiringtheusertoclearflowalertsmanual-ly.Ifmanualoperationisselected,irrigationwillnotoccuronalertedstationsuntilthefieldissueisfoundandresolved.Ifthereisaflowalertonthemastervalve,allirrigationwillbesuspendeduntiltheis-sueisresolvedandalertscleared.

Press theminusbutton to change this valueasneeded. Press therightarrowbuttontomovetothenextscreen.

Set Flow Meter SizeThechoicesofflowmetersizesare1”,1.25”,1.50”,2.00”,3.00”,4.00”andInsertType. Presstheminusbuttontoselectthesizethatmatchestheflowsensorinstalled.Ifaflowsensorsmallerthan1”isused,thenselect“Insert-Type”andentertheKandOffsetvalueforthesizebe-ingusedasfoundinthemanufacturer’sinstallationmanual.Presstherightarrowbuttontomovetothenextscreen.

View /Edit K and Offset ValuesWhenaflowsensorsizeisselected,itscorrespondingdefaultKandOffsetvaluesaredisplayedintwoconsecutivescreensandrepresentPVCpipingvalues.Ifanotherpipingmaterialisbeingused,theseval-uescanbeedited.Whenedited,thecontrollerwilldisplaythedefaultandeditedvaluesforcomparison.

Note:Ifaflowsensor’sKorOffsetvalueiseditedandadifferentsizeflowmeterisselected,theeditedvaluewillreplacethedefaultvalueuntilrevised.

PresstheSELECTbuttontoedit.Allcharacterscanbeeditedinclud-ingthe“+”and“-“values. Presstheplusorminusbuttontochangethevalueandtherightarrowbuttontomovetothenextvalue.Presstherightorleftarrowtoexitthesubmenu.

Ifusingothercompatibleflowsensorsasidentifiedinthechartbe-low,edittheKFactorandOffsetvaluesfromthecontroller’sdefaultsettings.

Function WeatherTRAKPro3offersaflowmonitoringfeaturecalled“LearnedFlow.”Thisfeaturecomparesindividualstationflowsagainstapreviously“learnedflow”valueandwilltriggeranalertmessageifadefinedflowthresholdanddelayperiodisexceeded.

SetupAllof theLearnedFlowsetup functionscanbe found in the“Flow”menu. Toutilize this feature,acompatibleflowsensormustbe in-stalledandsetupproperly.(Seelistofcompatibleflowsensorbelow.)

Note:WeatherTRAKETPro3seriesiscompatiblewithDataIndustrial“IR”seriesandCreativeSensorTechnologyflowsensormodelsinvarioussizes.

Toconfigureflowmonitoringandlearnedflowfunctions,followtheenclosedsequenceofscreensandsubmenus.StartbypressingtheFlowmenubutton.

Measured FlowThis screen displaysmeasured flow at all times, regardless of howmanystationsarecurrentlyoperating.Ifmorethanonestationisop-erating(scheduledormanualstations),thedisplaywill indicatethecombinedflowrate.Ifnoirrigationiscurrentlyoperating,butflowisbeingindicated,thevaluemayindicatealeaksituationthatneedsattention.Presstherightarrowbuttontomovetothenextscreen.

Select Flow Meter ModeToinitiateanyflowmonitoringfunctions,theflowmetermodemustfirstbe changed from the factorydefault settingof“Off”.Press theminusbuttontochangetheflowmetermodefrom“Off”to“1.”Presstherightarrowbuttontomovetothenextscreen.

Page 19: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Flow Reference Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3FRG0513 19 800.362.8774 • www.hydropoint.com

Compatible Flow Sensor – K and Offset Values

Manufacturer

FlowSensororHydro–

Meter Size KFactor Offset

CreativeSensorTechnology(001series)

1” +00.320 +00.022

1-1/2” +00.650 +00.750

2” +01.192 +00.938

DataIndustrialPVCmodels

735series ½” +00.07800 +00.90

735series ¾” +00.1563 +00.90

735series 1” +00.261119 +01.200

228series 1-/12” +01.697 -00.316

Netafim(Register-Typeonly)

1” +06.00 +00.0000

1-1-/2”,2”,3”&4”

+60.00 +00.0000

Edit Excluded Stations from No Flow AlertsInsomeapplicationstheflowratevarieswidelybasedonthetypeofsprinklersinstalled.Insomecasestheflowrateofthedripemittersistoolowtobereadaccurately.Thecontrollerwilloperatestations,butwillnotbeabletorecordanaccurateflowrateandmayfalselypostaNoFlowAlert.Toavoidthisoccurrence,selectstationstobeexcludedfromNoFlowAlerts.

PresstheSELECTbuttontoviewthefirst8stations.Presstheplusorminusbuttontochangethevaluefrom“-“to“EX”forexclude.Presstherightarrowbuttontomovetothenextstationornextsetof8stationsuptothecontroller’smaxactivestations.Pressingthe*but-tononthesescreenswillalternatebetweenselectingallstationsandselectingnostations.Presstheleftorrightarrowbuttontotheendtoexitthesubmenu.

Settingflowthresholdsaccuratelywillreducethepotentialforfalseflowalerts.Thefollowingrulesofthumbaresuggestionstoreducethisoccurrence.Takingafewmomentstorecordeachstationsflowratewillprovideareferencetomakethresholddecisionseasierandfaster.

•Mainline Break Threshold – Generally, selecting a value 20%

higher than the stationwith thehighest flow ratewill suffice.

This value is set in GPM. If two or more stations are being

operatedatonetime,selectaGPMthatcombinesthestation(s)

withthehighestflowrate.

•StationHighFlowThreshold–Twochoicesareavailable;1)select

a%abovethe“learnedflow”rate.The%isappliedtoallstations

globally.2)EnterindividualstationhighflowthresholdsinGPM.

Eithermethodcanbeusedforeachstation.

•NoFlowThreshold–Selectingaflowvalueatleast15-20%less

thanthestationwiththelowestflowratewillsuffice.Reference

thelearnedflowvaluestomakethisdetermination.

•Leak Detect Threshold – If a site incorporates quick couplers,

hosebibsorafillpipeforapond,selectathresholdGPMhigher

thanthisdemand.

•SettingaDelayPeriod–This represents a time lengthofhow

longthecontrollerwillwaitforflowtostabilize.Whenthedelay

expiresandaflowthresholdisexceeded,thecontrollerwillraise

analertandtakecorrectivemeasures.Thefactorydefaultperiod

is3minutes.Therangeis1-6minutesin1minuteincrements.

Set Mainline Break Threshold and Delay Themainline break threshold should be higher than the station(s)withthehighestflowrate.Forexampleifthestationwiththehighestflow is60GPM, then20%higherwouldbeapproximately75GPM.Forthresholdsof30GPMandlower,theGPMvaluecanbeset in1GPMincrements,andforGPMvalueshigherthan35GPM,theincre-mentis5GPM.

Presstheplusorminusbuttontoincreaseordecreasethefactoryde-faultvalueof50GPM.PresstherightarrowbuttontoselecttheDelayPeriod.Thisvaluecanbechangedbypressingtheplusorminusbut-ton.Presstherightarrowbuttontothenextscreen.

Note:AnyFlowMonitoringfeaturecanbeturned“Off”independentlyofotherflowmonitoringfunctionsbypressingtherightorleftarrowbuttontothezerovalue,whichwilldisplayas“Off”.

Set No Flow Threshold and DelayTheNoFlowThresholdisintendedtonotifyauserifapumpstationfails, thebackflowdevicehasbeenshut-off,a remotecontrolvalvefailstoopen,orifanisolationvalveinthemainlinehasbeenturnedoff. Set theNoFlow thresholdat least15% lower than thestationwiththelowestflowvalue.

Presstheplusorminusbuttonincreaseordecreasethefactoryde-faultvalueof5GPM.PresstherightarrowbuttontoselecttheDelayPeriod.Thisvaluecanbechangedbypressingtheplusorminusbut-ton.Presstherightarrowbuttontomovetothenextscreen.

Page 20: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Flow Reference Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3FRG0513 20 800.362.8774 • www.hydropoint.com

Set Leak Detect Threshold and DelayThe controller will continuously monitor for leaks when irrigationisoffandduringscheduled irrigationwith longsoakperiodswhennoirrigationisactuallyoperating.Thecontrollerwillsimplypostanalertofaleak,butthecontrollerwillnottakefurtheraction.Usethe“ExtendedLeak”featuretoisolatethemainlinewhennormallyopenmastervalvesareinuse.

Presstheplusorminusbuttontoincreaseordecreasethefactoryde-faultvalueof15GPM.PresstherightarrowbuttontoselecttheDelayPeriod.Thisvaluecanbechangedbypressingtheplusorminusbut-ton.Presstherightarrowtomovetothenextscreen.

Set Extended Leak DelayThis feature is exclusive to irrigation systems that incorporate nor-mallyopenmastervalveswherealeakisdetected.Correctiveactionisneededtopreventwaterwastageorpropertydamagefromsatu-ratedsoilfromacontinuousleak.

IfaleakpersistsbeyondtheLeakDetectdelayperiodandthenbe-yondtheExtendedLeakDelayperiod,thecontrollerwillimmediatelypostanExtendedLeakAlertandcloseanormallyopenmastervalve.

Anexampleofhowthisworksmightbewhenawindowwashercon-nectsintoaquickcouplerontheirrigationmaintofillbucketsofwa-terinordertowashwindows.FillingthebucketsinitiallymaycauseaLeakDetectAlert.IfthewaterisleftonbeyondtheExtendedLeakdelaytimeperiod,thecontrollerwilltakecorrectiveaction.

TheExtendedLeakalertallowsnormalirrigationtooccurassched-uled.Ifthewindowwashercorrectstheconditionbyturningthewa-teroff,thecontrollerwillautomaticallyclearthealertafterthenextirrigationcycle.

While remaining in the“Leak Detect” screen press the right arrowbuttontothefieldfollowing“+”toselecttheExtendedLeakDetectDelayPeriod.Thisvaluecanbechangedfrom“Off”toaselectedvaluebypressingtheplusorminusbutton.Therangeis1-240minutesinone-minuteincrements.Presstherightarrowbuttontomovetothenextscreen.

Set Station High Flow Offset %Thestationhighflowthresholdvaluecanbesetusingapercentagethatappliesgloballyforallstations.Thepercentagerangesfrom5%to80%aboveeachstation’s“LearnedFlow”or“AssignedStationFlow”(ASF)value.Thepercentagevaluecanbesetin5%increments.

Press theplusorminusbutton to increaseordecrease the stationhighflowoffset%.Presstherightarrowbuttontomovetothenextscreen.

Note:TheStationHighFlowOffsetisusedinthefollowing“StationFlow”submenu.Thissubmenuletstheuserconfigureeachstationwitha“learnedflow”valueusingtheoffset,orwithaspecificuser-definedthresholdGPM.

View Station FlowInthissubmenuthecontrollerwilldisplaya“learnedflow”valueor“AssignedStationFlow”(ASF)foreachstation.Thisvaluecanbe(a)avaluemeasuredduringlearning,or(b)auser-definedvalue.Ifthestationscreendisplays“Unk”,thevalueisnotlearnedoruser-defined,andis“unknown.”

Use the arrowbuttons andplus andminusbuttons tonavigate asfollows:Ifthe“AssignedStationFlow”istobeedited,presstheplusorminus buttons to set a user-defined value. If a value has been“learned”andtheASFisnotcurrentlythe“learned”value,thiswillbeindicatedonthethirddisplayline.The“learned”valuecanbesetbypressingthe*button.

Press the right arrowbutton to select StationHighFlowThreshold(SHFT).Thisvaluecanbesetto(a)theASFvalueplustheOffsetsetpreviously,or(b)auser-definedvalue.Presstheplusorminusbuttontosetauser-definedvalue.IftheASFvalueisnot“Unk”,pressingthe*buttonsetsSHFTtotheASFplusoffsetvalue.Presstherightarrowbuttontomovetothenextstation.

Learning Station Flow

Select Stations to Learn FlowThis submenu lets theuser select stationsonwhich toLearnFlow.Thefactorydefaultis“NoLearnStations.”Learningeachstation’sflowrateisrequiredforthecontrollertooperate,storeandthencompareforaccurateflowmonitoring.Oneormorestationscanbeselected.Pressingthe*buttonwillalternatebetweenselectingallstationsandselectingnostations.

Note: Ifastation’sflowratehasbeenpreviouslylearned,thecontrollerwillonlydisplaythemostrecentlylearnedvalue.Theglobalstationoffsetpercentageisappliedtothisvalue.

ToselectastationtoLearnFlow,presstheSELECTbuttontoviewthefirst8stations.Press theplusorminusbuttontochangethevalueunderthecorrespondingstationnumberof“—“to“LF”forLearnFlow.Presstherightarrowbuttontomovetothenextstation.Repeatthisprocessasoftenasneeded.Presstherightorleftarrowbuttontotheend(ineitherdirection)toexitthesubmenu.

Set Delay Before LearningThisdelaytimecorrespondstohowlongthecontrollerwillallowflowtostabilizebeforerecordingastation’s learnedflowvalue.Anotherway to thinkabout this is selecting thestations run-time. This isaglobalsettingappliedtoall stations thatare learning. If somesta-tionsrequirealongerdelayperiodtoensureaccuraterecording,theywillneedtobelearnedseparatelywithalongerdelayperiod.Allow-ingtoolittletimeforlearningcouldleadtofalseHighStationFlowAlerts.

Therangeofthedelayperiodis3-10minutesin1-minuteincrementsandthefactorydefaultvalueis3minutes.

Page 21: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Flow Reference Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3FRG0513 21 800.362.8774 • www.hydropoint.com

Note:Forsomestationsthatareend-fedfromavalvewithlonglateralruns,thedelaytimemayneedtobeextendedtoensurethesystemhasbalancedbeforeaflowvalueisrecorded.

Presstheplusorminusbuttontoincreaseordecreasethedelaype-riodin1minuteincrements.Presstherightarrowbuttontomovetothenextscreen.

Learn Flow (On/Off)Nowthatallof theLearnedFlow requirementsareconfigured, thecontrollercanoperateeachstationindependentlytorecordstation’slearnedflowrate.

Note:NootherirrigationshouldbeoperatingduringtheLearnFlowtimeperiodwhetheritisscheduledormanualirrigation.Thiskeepsthecontrollerfromrecordingfalseflowvalues.

TostarttheLearnFlowoperation,presstheplusorminusbuttontochangethevaluefrom“Off”to“On”.Thisoperationcanbeinterruptedatanytimebypressingtherightorleftarrowbackto“Off”.Ifthistaskisinterrupted,thecontrollerwillpreservethepreviouslyselectedsta-tionsthathaveyettobeoperatedandwillcontinuelearningwhenturnedback“On”.Thecontrollerwilldisplaythestationnumber,theremainingtimelefttorecordthestationlearnedflowvalue,andtheactualflowvalueinrealtime.

Note:Isitsuggestedthatthe“Flow”menupositionremainonuntilthisoperationiscompleted.Whenlearningisinprogress,thetext“LRNXX”(whereXX=stationnumber)isshowninthelowerright-handcornerofthescreen.

IfnostationshavebeenselectedtoLearnFlow,thesecondlineofthescreenwilldisplay(NoLearnStations).

PresstherightarrowbuttontomovethedisplaytothelastFlowsub-menuscreenor“FlowMenuComplete,”thenpresstheRunmenubut-tonoranotherpositionasneeded.

Need Help?Formoredetailedinformationonflowmonitoring,Alerts,Alertclearing;downloadandprinttheOwner’sManualfrom www.Hydropoint.comorcallHydroPointCustomerServiceat(800)362-8774(www.Hydropoint.com)[email protected]

Page 22: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain
Page 23: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

hydropoint.com

WeatherTRAK ET Pro3

Troubleshooting Guide

WeatherTRAK ET Pro3 Troubleshooting Guide

Page 24: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 24 800.362.8774 • www.hydropoint.com

WeatherTRAK ET Pro3 Central AlertsWeatherTRAKETPro3AlertsaresenttoourWeatherTRAKserverinatimelyfashionandcanalwaysbeviewedontheAlertswebpage.Userscanelecttobenotifiedbyemailortextmes-sagewhenthealertsareraisedandclearedbysettingupAlertNotificationsontheUserPref-erenceswebpage.

Allalertsindicatethatsomethingiswrongandshouldbeinvestigated.Criticalalertsrequireurgentattention.Majoralertsshouldbeinvestigatedpromptly.

AlertsaresummarizedbyAlertCategorylistedas:

System Alerts (Flow and Valve Alerts) Communication Alerts•MainlineBreak(MB)

•StationHighFlow(HF)*

•NoFlow(NF)

•Leak(LK)

•ExtendedLeak(EX)*

•ValveShort(SH)

•ValveOverCurrent(OC)*

•ValveNoConnect(NC)

•Hardware(HW)

•SystemOverCurrent(SOC)*

•ControllerOffline(OFL)

•NoETCommunication(CM)

Program Alerts Account Alerts Irrigation Alerts•WaterWindow(WD)

•WaterDay(DY)

• ETSubscription(SB) •ControllerOff(CO)*

•SystemShutdown(SD)*

•ControllerPaused(CP)

•ManualIrrigation(MI)

Notes about the automatic clearing of Flow Alerts• In5.0and5.6controllers,flowalertsareclearedautomaticallyattheProgramAstart

time.• In6.0+controllers,FlowAlertClearingcanbesettoAutoorManualonthecontroller.

• IfFlowAlertClearingissettoAuto,theFlowAlerts,excepttheExtendedLeakAlert,areclearedautomaticallyattheProgramAstarttime.

• IfFlowAlertClearingissettoManual,theFlowAlerts,exceptfortheLeakDetectAlert,mustbeclearedbytheuser.

• Automatic Leak Alert Clearing: The Extended Leak Alert will not be clearedautomaticallyatProgramAstarttime,butwillberetestedafterirrigationandmaybeclearedatthattime.TheLeakDetectAlertalwaysclearsautomaticallyatProgramAstarttime.

• ToclearFlowAlertsatthecontroller,presstheALERTSbuttononthemainmenu.PresstherightarrowbuttonuntilVIEWFLOWSTATUSappears.Pressthegreen*buttontoclearallFlowAlerts.

Notes about Valve Alerts• ValveAlertsareonlyreportediftheRTVTissettoOn,SetupMenuonthecontroller,

ProgramPageSetupPanelontheweb.In5.6and6.0+controllers,avalvetestisalwaysrunatProgramAstarttime.

• ToclearValveAlertsatthecontroller,presstheALERTSbutton.PresstherightarrowbuttonuntilVIEWVALVESTATUSappears.PresstheplusorminusbuttontochangeSkiptoView.Presstherightarrowbuttontoenterstatusscreen.Pressgreen*button.

• TocleartheSOCalertatthecontroller,presstheALERTSbutton.PresstherightarrowbuttonuntilVIEWVALVESTATUSappears.PresstheplusorminusbuttontochangeSkiptoView.PresstherightarrowbuttontoviewSYSTEMOVERCURRENT.Pressgreen*button.

Alerts - Controller BeepingWhy does a Controller Beep? Thecontrollerwillbeepat8:00amwhencommunicationhasnotbereceivedfor5consecu-tivedaysorWeatherTRAKCentralsubscriptionisabouttoexpireorhasexpired.

Note:Pressinganybuttonwillstopthebeepinguntil8:00amthenextday.BeepingwillstopwhencommunicationisrestoredorthesubscriptionisrenewedbycallingWeatherTRAKCustomerService.

AlertsTherearesixcategoriesofalerts:FL(Flow),VL(Valve),CM(Communication),WD(Window),DY(Day),HW(Hardware),SB(Subscription).“ER”indicatesanalertexistsforaparticularstation.“--“indicatesnoalertexists.

View / NavigationPresstheALERTSMenubutton. Thissummarywilldisplaythe7majorcategoriesofalerts.Presstherightorleftarrowbuttonfindthealertcategory.Presstheplusorminusbuttontochangefrom“Skip”to“View”.Presstherightorleftarrowbuttontoscrollalldatawithinthatparticular alert.

Clearing AlertsThefollowingAlertscanbeclearedbypressingthe*buttonwhileintheinthespecificAlertscreen:

• AllFlowAlerts• AllValveAlerts

ThefollowingAlertsmustbeclearedbychangingprogrammingparameters:• WaterDayAlerts• WaterWindowAlerts

ThefollowingAlertsmustbeclearedbyWeatherTRAKCustomerService:• SubscriptionAlerts• CommunicationAlerts

HardwarealertsmayrequireaservicecallifitcannotberesolvedoverthephonewithCus-tomer Service.

Page 25: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 25 800.362.8774 • www.hydropoint.com

Definition of AlertsFlow AlertsTheWeatherTRAKETPro3softwarecancontinuouslymonitorforthefollowingflowcondi-tions:

• MB(MainlineBreak)—AMainlineBreakalertgenerallymeansamainlinepipeorfittinghasfailed.

• HF(StationHighFlow)—AstationHighFlowalertisgenerallywhenasprinklerheadorlateralpipeisbrokenorleaking.

• NF(NoFlow)—ANoFlowalertmeansanoperatingstationisnotrecordinganyflow.

• LK (Leak Detect)— A Leak Detect alert is when flow is observed during non-scheduledirrigationorduringscheduledirrigationwhennoirrigationisoperating.

• EX(ExtendedLeakDetect)whenaflowmeterisused—AnExtendedLeakDetectalertisifaleakexceedsauser-defineddelayperiodwithanormallyopenmasteraspartoftheirrigationsystem.

FormoredetailsaboutAlertsdefinitionsprinttheOwner’sManualforwww.hydropoint.com.Seethe“LearnedFlow”ReferenceGuideinthecontrollerliteratureforanoverviewofthisfeature.

Note:IfaFlowAlertisposted,confirmaflowmeterisinuse.IfnoFlowmeterexists,PresstheFLOWMenubuttontoturntheFlowMeterstatusto“Off”.Remembertoclearthisalert.

Valve AlertsTherearetwokindsofvalvealerts:

• SH(Short),afailedsolenoid• NC(NoConnect),abrokenwire

Note:Notclearingvalvealertsmaycausestationswithalertstonotoperate.

Communication AlertsAcommunicationalertindicatesthedailyETweatherupdatewasnotreceived.

Water Window AlertsThetotalruntimeforaprogramisgreaterthanthelengthofthewaterwindow.Thisprob-lemwillbecomeworseasETincreases.Increasethewaterwindoworassignsomestationstoanotherprogramtoremovethisalert.

Note:Enteringprogramsthatexceedthewaterwindowmaydamageyourlandscape.

Day AlertThisalertoccurswhenstationdepletionisreachedbeforethenextscheduledwaterday.Thishappenswhenarestrictivedaypatternisselectedoradayisexcludedformowing.Notre-solvingthisproblemmaycausedamagetoyourlandscape. Dayalertscanonlybeclearedbyremovingthedayrestrictionorbyturningoff-daystoon.Itisnormaltohaveadayalertinthesummeronaturfprogramwhereadayhasbeenomittedformowing.Removingtheexcludeddayisoptional.

Hardware AlertPresstherightorleftarrowbuttontoHARDWARE.ThisalertindicatesthatthecontrollerisseeinglessavailablestationsthanaresetinMaxActiveStations.Commoncausesarealooseribboncableoradamagedoutputboard. CallCustomerServicefortroubleshootingassis-tance.

Note:Hardwarealertscanonlybeclearedbycorrectingthehardwareproblem.CallWeatherTRAKCustomerServiceforassistance.

Subscription AlertThisalertindicatesthattheWeatherTRAKETEverywhere™subscriptionhasexpiredorisabouttoexpire.

Page 26: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 26 800.362.8774 • www.hydropoint.com

System AlertsSystemAlertsreflectproblemswiththecontrollerhardwareandcouldaffectscheduledirrigation.

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearMainline Break

MB Critical FlowhasexceededtheMainlineBreakThreshold.

Duringcontroller-ini-tiatedirrigation:Thecontrollerclosesthestationvalve(s).

•Locateandfixbreak.

•Locateandreplacethebrokenfitting.

Atthecontroller,selecttheALERTSmenu.ViewtheFLOWSTATUSscreen.Pressthe*buttontoclearallflowalerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”

Seenotebelowabouttheautomaticclearingoftheflowalerts.

StationHighFlow*

HF Major FlowhasexceededtheStationHighFlowthreshold.

Possiblecauses:•Abrokensprinklerhead.

•Abrokenlateralpipe.

•TheStationHighFlowthreshold(SHFT)istoolow.

Thecontrollerstopsirrigationonthesta-tionthatwasirrigat-ing,raisestheStationHFalertonthatsta-tionandmovestothenextstation(s)inthescheduledsequence.ThecontrollerbemaysettoautomaticallyclearandretestforthisalertatthestartofProgramA.Seeowner’smanualforFlowAlertClearing.

•Locateandreplacethebrokensprinklerheads.

•Repairthebrokenlateralpipe

•ConfirmtheStationHighFlowThresh-oldsettingiscorrect.

Atthecontroller,selecttheALERTSmenu.ViewtheFLOWSTATUSscreen.Pressthe*buttontoclearallflowalerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”

Seenotebelowabouttheautomaticclearingoftheflowalerts.

NoFlow NF Major FlowhasdroppedbelowtheNoFlowthreshold.

Possiblecauses:•Thesolenoidplungernotliftingtoallowvalvetoopen.

•TheMasterValvenotopeningifinuse.

•ThePumpStartnotbeingacti-vated.

•Agatevalveorisolationvalveinthemainlinehasbeenclosed.

Thecontrollerstopsirrigationonthestation,raisesaNoFlowAlertonthesta-tionandthenmovestothenextstationinthescheduledsequence.IfthreeconsecutivestationshaveNoFlowalerts,thecontrollerstopsirrigation.

•Bleedthecorrespondingvalvemanu-allytodetermineifwaterpressureexists.

•VerifythePumpStartisoperatingcor-rectly.

•Locateandopenanyclosedgatevalves.

Atthecontroller,selecttheALERTSmenu.ViewtheFLOWSTATUSscreen.Pressthe*buttontoclearallflowalerts.

Seenotebelowabouttheautomaticclearingoftheflowalerts.

Page 27: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 27 800.362.8774 • www.hydropoint.com

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearExtendedLeak*

EX Major FlowhasexceededtheLeakDetectthresholdcontinuouslyfortheextended leak period.

Possiblecauses:•Someoneisusingaquickcouplerorhosebib.

•Astuckopenvalve.

•Abrokenmainlinefitting.

ThecontrollerclosesaNormallyOpenMas-terValveandraisesanExtendedLeakAlert.Thenextirrigationwillstartasscheduledbutthealertwillnotbeclearedautomati-cally.

•Repairanyvalves,quickcouplersorhosebibs.

•Preventtheunauthorizeduseofaquickcouplerorhosebib.

Atthecontroller,selecttheALERTSmenu.ViewtheFLOWSTATUSscreen.Pressthe*buttontoclearallflowalerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”

Seenotebelowabouttheautomaticclearingoftheflowalerts.

Leak LK Major FlowhasexceededtheLeakDetectthresholdforthefirstleakdelayperiod.

Possiblecauses:•Someoneisusingaquickcouplerorhosebib.

•Avalveisnotclosingcompletelyandisleaking.

•Amainlinefittinghasacrackandisleaking.

•Amainlinepipehasdevelopedaslowleak.

•Aquickcouplerisstuckpartiallyopenorahosebibhasbeenleftopen.

Thisisaninformation-onlyalert.Noactionwillbetakenonthecontroller.

•Repairanyvalves,quickcouplersorhosebibs.Preventtheunauthorizeduseofaquickcouplerorhosebib.

Atthecontroller,selecttheALERTSmenu.ViewtheFLOWSTATUSscreen.Pressthe*buttontoclearallflowalerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”

Seenotebelowabouttheautomaticclearingoftheflowalerts.

ValveShort SH Major Thecurrentdrawforassinglevalvesolenoidhasexceeded3.0amps.

Possiblecauses:•Afailingsolenoid.

•Anickedwireisexposedtowetsoil.

•Abrokenwirehasbeenexposedtowetsoil.

Thecontrollerstopsirrigationforthespe-cificvalveandraisesaValveShortAlertonthevalve.IfthevalveistheMasterValve,allirrigationstops.IfitisthePumpStartvalve,irrigationstopsun-lesstheprogramhasPumpStartExcluded.

•DisconnectthesolenoidfromthefieldwireandconductanOhmstesttoseeifsolenoidisdefective.IfOhmsreadingislessthan10Ohmsreplacethesolenoid.

•Useawiretrackertolocateafieldwirespliceandreplace.

•Lookforobvioussignsofsitedisrup-tionthatcouldhaveleadtomechanicaldamagetoafieldwire.Replacethefieldwire.

Atthecontroller,selecttheALERTSmenu.ViewtheVALVESTATUSscreen.Pressthe*buttontoclearallvalvealerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”.

Seenotebelowabouttheautomaticclearingofvalvealerts.

System Alerts continued

Page 28: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 28 800.362.8774 • www.hydropoint.com

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearValveOverCurrent*

OC Major Thecurrentdrawforassinglevalvesolenoidhasexceededthestationelectricalthreshold.Seecontrollermanualforspecificthreshold.

Possiblecauses:•Afailingsolenoid.

•Anickedwireisexposedtowetsoil.

•Twostationsarebridgedintoonestationoutputandthecurrentdrawistoohigh.

Thecontrollerstopsirrigationforthespe-cificvalveandraisesaValveOverCurrentAlertonthevalve.IfthevalveistheMasterValve,allirrigationstops.IfitisthePumpStartvalve,irrigationstopsunlessthepro-gramhasPumpStartExcluded.

•DisconnectthesolenoidfromthefieldwireandconductanOhmstesttoseeifsolenoidisdefective.IfOhmsreadingislessthan10Ohmsreplacethesolenoid.

•Useawiretrackertolocateafieldwirespliceandreplace.

•Removeoneoftwobridgedstations.

Atthecontroller,selecttheALERTSmenu.ViewtheVALVESTATUSscreen.Pressthe*buttontoclearallvalvealerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”.

Seenotebelowabouttheautomaticclearingofvalvealerts.

ValveNoConnect

NC Major Thecurrentdrawforavalvesole-noidisbelow75mA.

Possiblecauses:•ThenumberofMaxActiveStationsexceedsthenumberofstationsphysicallyconnectedtothecon-troller.

•AribboncablebetweenstationPCBsispartiallydisconnectedorstationkeysaremissing.

•Nofieldwireisconnectedtoaspecificstationoutput.

•Thefieldwireterminatedinthesta-tionoutputisnotmakingpropercontact.

•Thefieldwireisbrokenorthereisacorrodedorfailedsplice.

ThecontrollercannotoperatethisvalveandwillraiseaNoConnectAlertonthevalve.IfthevalveistheNormallyClosedMasterValve,noir-rigationwilloccur.

•ReducethenumberofMaxActivesta-tionsintheSETUPmenu.

•Re-insertorrepairtheribboncableandverifysufficientstationkeys.

•Ifvalvesolenoidshavelowcurrentdraw,bridgetwovalvestoonestationoutput.

•ConductanOhmstestonafieldwirewhilethesolenoidremainsdiscon-nected.IfOhmsvalueishigherthat10Ohms,afieldwireorbadspliceexists.IfOhmsreadingonsolenoidisgreaterthan100,replacethesolenoid.

Atthecontroller,selecttheALERTSmenu.ViewtheVALVESTATUSscreen.Pressthe*buttontoclearallvalvealerts.

or

GotoManagepageinWeatherTRAK.netandselect“ClearFlowandElectricalalerts”.

Seenotebelowabouttheautomaticclearingofvalvealerts.

System Alerts continued

Page 29: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 29 800.362.8774 • www.hydropoint.com

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearHardware HW Major Thecontrollerisnotdetectingall

oftheuser-definedMaxActiveSta-tions.

Possiblecauses:•Theuser-definedMaxActiveSta-tionsexceedsthenumberofsta-tionsdetectedbythecontroller.

•OneormoreStation-Keysaremiss-ingorimproperlyinstalled.

•Theribboncablebetweenstationinput/outputboardsisdefectiveorconnectingpinsarebent.

•Astationoutputboardhasbeendamaged.

Thecontrollercannotirrigatestationsthatare not detected.

•VerifyMaxActiveStationsinSETUPmenu.

•Confirmribbonscablesareseatedproperly.

•VerifythenumberofStationKeysisadequatefortherequiredstations.

•Useanotherribboncableorun-bendtheconnectorpins.

•Lookforscorchmarksontheboardorastrongodorofburntcomponents.Replaceasneeded.

Approximately30secondsafterthesitua-tionisremedied,thecontrollerautomaticallyclearsthisalert.

SystemOverCurrent*

SOC Major Thecurrentdrawforagroupofstationshasexceeded2.7ampsor2700mA.

Probablecause:•Toomanystationsirrigatingatthesametime.

Thecontrollerau-tomaticallyreducesthenumberofvalvesirrigating,droppingmanual irrigation and less-depletedstationsfirst.

•Re-programthecontrollertoreducethenumberofstationsoperatingatthesametime.

TocleartheSOCalertatthecontroller,selectALERTS,thenVALVESTATUSthenSYSTEMOVERCURRENT.Pressthe*buttontoclear.

Communication AlertsCommunicationAlertsindicateproblemsexchanginginformationwiththecontroller.

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearController Offline

OFL Major ThecontrollerhasnotcommunicatedwiththeWeatherTRAKCentralserverrecently.

Possiblecauses:•Controllerpowerhasbeenturnedoff.

•Two-wayphaseintegritiesarelow.

•2-waycontrollersetto1-wayinADVANCEDmenu.

Unlessthepowerisoff,thecontrollerwillcontinuetoirrigateasscheduled,however,thecontrollermaynotre-ceiveETmessagesandthecontrollermaynolongerbesynchronizedwiththewebsite.

•RestoreACpoweriflost.

•Verifyphaseintegrities.

•SetcommunicationintheADVANCEDmenuto2-way.

Alertwillautomaticallyclearwhencommunicationisrestored.

NoETCommuni-catio

CM Major EThasnotbeenreceivedfor5days.

Possiblecauses:•Impropermicrozonehasbeenassignedtothe

controller.

•ETSubscriptionhasexpired.

ThecontrollercontinuestoirrigateallstationsusingthelastreceivedETmessagefor5days.After5daysthecontrollerwillusethebackupET.

•CallHydroPointCustomerServicetoverifymicrozoneandaskforanewETsignaltobesent.ConfirmETmes-sageisreceived

•RenewWeather-TRAKETEverywhereSubscription.

AlertwillautomaticallyclearwhenanewETmes-sageisreceived.

System Alerts continued

Page 30: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 30 800.362.8774 • www.hydropoint.com

Program AlertsProgramAlertsindicatethattheirrigationschedulingneedsmodification.

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearWaterWin-dow

WD Minor Theuser-definedwaterwindowistooshortforthenumberofstationsassigned.

Possiblecause:•Currentweatherconditionsrequireruntimesthatexceedthelengthofthewaterwindow.

Thecontrollerproportionatelyre-ducesallstationruntimestofitwithintheuser-definedwaterwindow.Thelandscapemaybeatriskduetoinsuf-ficientirrigation.

•IncreasethelengthofthewaterwindowintheDAYS/TIMESmenu.

•Assignsomestationstoanotherprogram.

Re-programmingthecon-trollerwillprobablyclearthealert.

WaterDay DY Minor Somestationsareassignedtoaprogramthathastoofewdaysofirrigation.

Possiblecause:•Currentweatherconditionsrequiremorefrequentirrigation.

Thecontrollercontinuestoirrigate,tryingtocompensatebyextendingruntimeswherepossible.Theland-scapemaybeatrisk.

•Changetheprogram(DAYS/TIMESmenu)toincreasethenumberofwaterdays.

•Assignthestationstoaprogramwhichhasmorewaterdays.

Re-programmingthecon-trollerwillprobablyclearthealert.

Account AlertsAccountAlertsindicatethattheETEverywheresubscriptionhasexpired.

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearETSub-scription

SB Minor TheWeatherTRAKETEverywhereSub-scriptionServicehasexpired.

Thecontrollerwillcontinuetoirrigatebutat8:00AMeverymorning,theControllerwillstartbeepingevery30seconds.

•CallCustomerServiceandrenewtheWeatherTRAKETEverywhereSubscrip-tion.

•ChangeallstationstoUserNoET.

Renewingtheservicewillclearthealert.

Irrigation Status AlertsIrrigationStatusEventsindicatethatthecontrollerisOff,Shutdown,Paused,orinManualIrrigationmode.

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearController Off*

CO Low Auserhasturnedoffallirrigation.Thiswasdonebypressingthemainfunctionbuttonto“OFF.

Possiblecauses:

•Controllerhasbeenturnedoffforrepairs,pesti-cide/insecticideapplicationorspecialevent.

•Controllerhasbeenturnedoffforwinterization.

Thecontrollerstopsallscheduledirrigationindefinitelybutleavesanor-mallyopenmastervalveinthe“open”ordefaultposition.ThecontrollerwillcontinuetoreceivedailyET’sandcalculatestationspecificdepletion.

•Notapplicable Pressthemainmenubuttonfromthe“OFF”to“RUN”position.

SystemShutdown*

SD Low Auserhasturnedoffallirrigationandactuatedamastervalve.

Possiblereason:•Acatastrophiceventhasoccurredwhereauserneededtoensurethatthemastervalveisclosed.

Thecontrollerstopsallscheduledirrigationindefinitelyandclosesanormallyopenmastervalve.ThecontrollerwillcontinuetoreceivedailyET’sandcalculatestationspecificdepletion.

•Notapplicable Takethecontrolleroutofthe“Sys-temShutdown”modefromtheOFFmenubypressingthe*buttonandselecttoRUNmenu.

Page 31: Activate your WeatherTRAK Pro3 Pre-activate to expedite at ... · Station Output Board Design Note: Station output boards 12-24 and 25-48 are identical, but do not support two rain

WeatherTRAK Troubleshooting Guide

©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3TG0513 31 800.362.8774 • www.hydropoint.com

Alert Type Abbr. Severity Definition/Possible Causes Controller Action Possible Remedies How to ClearManual Ir-rigation*

MI Low Thecontrolleriscurrentlymanuallyirrigating.Todeterminewhichstation,gototheMANUALpageandview“ControllerOperatingStatus”fromWeatherTRAK.net.

Possiblecauses:•Auserhasstartedmanualirrigationonasinglestation,multipleorallstationsfromthecontrollerorfromtheWeatherTRAK.netcentral.

Thecontrollerwillrunallmanualstationsetupformanualirrigationprogram.Thecontrollercansupportbothscheduledandmanualirrigationatthesametime.

•Notapplicable Thiseventwillautomaticallyclearwhenmanualirrigationprogramiscomplete.Themanualirrigationprogramcanbestoppedim-mediatelyfromthecontrollerorWeatherTRAK.net.

Controller Paused

CP Low Thecontroller’sirrigationispausedeitherbyarainpauseorrainswitch.Somestationsmaystillirri-gateifthestation’suseablerainfallsettingisnone.

Possiblecauses:•ArainpausehasbeensetatthecontrollerorfromWeatherTRAK.netcentral.

•ArainpausewasautomaticallysetbyWeather-TRAK’sClimateCenter.

•Arainsensorhasbeenactivated.*

•Arainsensorhasfailedopen(norainhasoc-curred).

Thecontrollerstopsallscheduledirrigation(exceptstationswithuseablerainfallsettonone)andstopscalculat-ingdepletiononpausedstationsuntiltherainpausedurationhasexpired.

•None,ifithasrecentlyrained,thisisexpect-edcontrollerbehavior.Ifithasnotrainedandthepausewasgener-atedbyarainswitch,therainswitchshouldbechecked.

Setrainpausedurationto0daysonthecontrollerorfromWeather-TRAK.net.Bypasstherainswitch.

* These alerts are only available on the controllers with 6.0 or greater software.

Irrigation Status Alerts continued