ACS550 Presentation
-
Upload
panapakorn-shinawatra -
Category
Documents
-
view
241 -
download
2
description
Transcript of ACS550 Presentation
AC
S55
0 ©
AB
B O
y. -
2
ACS550, Standard Drive
ABB Standard Drive Part of the family - The ABB Drive
Reliable quality product Global support
Convenient with all the aspects Simple selection Excellence in connectivity Intuitive drive All inside as standard Proven Performance
AC
S55
0 ©
AB
B O
y. -
3
ACS550, Standard Drive
0,75 to 5,5 kW
up to 11 kW
up to 22 kW
up to 45 kW
up to 55 kW
up to 132 kW
up to 160 kW
up to 355 kW
Complete power range 0.75 - 355 kW, 1 - 500 HP 3 phase 230 V (up to 75 kW) and
400 V series IP21 / UL Type 1 IP54 / UL Type 12 (R1-R6 only)
AC
S55
0 ©
AB
B O
y. -
4
ACS550, Standard Drive Installation
550-01 Mounting options Wall Side-by-Side Flange
550-02 Mounting options Free standing Side-by side
AC
S55
0 ©
AB
B O
y. -
6
ACS550 – Selection
Relay Output Extension +L511
Type code shows output current and input voltage Control options can be ordered using plus codes or
as separate option kits
ACS550-01-06A9- 4+L511+K451
Output Current6.9 A
Input Voltage380 to 480 V
DeviceNet Adapter+K451
AC
S55
0 ©
AB
B O
y. -
8
ACS550 – Selection
Dimensions are in [mm]
R1 R2 R3 R4
369
212125
469
222125
583
231 203
262203
689
AC
S55
0 ©
AB
B O
y. -
9
ACS550 – Selection
Dimensions are in [mm]
R5 R6R7
R8
739
286 265
880
400300
1507
250 520
2024
347617
AC
S55
0 ©
AB
B O
y. -
10
ACS550 - Connectivity
Relay OutputExtension (3 x RO)
Plug-in Fieldbus Modules
Inbuilt Modbus
Extensive I/O- 2 x AI- 2 x AO- 6 x DI- 3 x RO
Easy connection to factory automation systems through multiple I/Os and plug-in options
AC
S55
0 ©
AB
B O
y. -
12
ACS550 - Connectivity
550 supports the new parameterization tool FlashDrop
For selecting and setting parameters Parameter set for non-connected drive In warehouse or during mechanical
installation Possibility to hide selected parameters
Machine protection Only essential parameters are shown
FlashDrop connection behind the control panel - protection class will remain
AC
S55
0 ©
AB
B O
y. -
13
ACS550 - Connectivity
All FBs are either embedded or mechanically installed inside the drive Modbus is the embedded fieldbus ACS 800 type Fieldbus modules are used to
provide remaining FBs Available fieldbuses:
PROFIBUS DeviceNet LonWorks ControlNet CANopen Ethernet (Modbus TCP & Ethernet/IP)
AC
S55
0 ©
AB
B O
y. -
14
ACS550 - Intuitive
Assistant control panel functions Run the assistants in conjunction with drive software Has help button giving manual information List of changed parameters Real time clock Fault Logger 15 languages supported in one panel
AC
S55
0 ©
AB
B O
y. -
15
ACS550 - Intuitive Basic control panel
7 segment display Implement panel protocol to display and modify parameters Upload or download capabilities Backlight
AC
S55
0 ©
AB
B O
y. -
16
ACS550 - Intuitive Buttons of the Assistant control panel:
Soft key 2
Help button
Start button
Soft key 1
Loc / Rem mode
Stop button
Soft key 2 Function
Soft key 1 function
Up and down buttons (to change parameters and their values)
AC
S55
0 ©
AB
B O
y. -
17
ACS550 - Intuitive
Start - Up assistantStart - Up assistant guides the user through all essential settings to be done without going directly into the parameter list.
Maintenance assistantMaintenance assistant can set the drive a criteria to insert preventive maintenance.
Timer Assistant helps in using timed functions Serial Communication Assistant for making
fieldbus setup simple and easy PID Assistant for feedback scaling and setting Drive Optimizer to optimize the drive in different
aspects Noise Efficiency Motor control performance
Assistants in the panel
AC
S55
0 ©
AB
B O
y. -
18
ACS550 - Intuitive
Fault Logger (Assistant panel only)
Easy way to find out What happened When happened
Tells drive status at the point of time the fault occurred Frequency, speed, torque, current, voltage etc…
Example: Panel Loss – fault 10 Panel tells the operator to “check: comm lines and connections,
parameter 3002, parameters in groups 10 and 11”
AC
S55
0 ©
AB
B O
y. -
20
ACS550 - Intuitive
DriveWindow Light 2 For commissioning the drive Possibility to monitor the drive Assistant to create direct configuration of the drive Remains compatible to other Low Voltage AC Drive
products
AC
S55
0 ©
AB
B O
y. -
21
The old way to do it...
ACS550 - All inside
…And ACS550
Built-in: - RFI filter, input choke, braking chopper (R1&R2), Modbus-(other fieldbuses as internal plug-in options)
EMC filter
Braking chopper input
choke
AC
S55
0 ©
AB
B O
y. -
22
ACS550 - All inside
Basic control panelAssistant control panel(as standard)
Plug-in Fieldbus
Relay OutputExtension Module
ACS550 internal options
AC
S55
0 ©
AB
B O
y. -
23
ACS550 – All inside
EMC filter
Cable lengths for 1st environment 75 – 300 m Cable lengths for 2nd environment 100 – 300 m
Detailed table on cable lengths available EMC environment explanation
AC
S55
0 ©
AB
B O
y. -
24
ACS550 – All inside New way to suppress harmonics caused by the inverter
“swinging choke”swinging choke” At partial load the swinging choke reactance increases THD reduction up to 24.2% compared to traditional choke
AC
S55
0 ©
AB
B O
y. -
25
ACS550 – All inside
“Swinging Choke” Designed to reduce harmonics at full and partial
loads Perfect for Variable Torque Centrifugal Loads
AC
S55
0 ©
AB
B O
y. -
26
ACS550 – Performance
Sensorless vector control Up to 12 kHz switching frequency at reduced current for
R1-R4 Automatic noise reduction
Switching frequency goes up when load decreases Noise smoothing function
Motor thermistor input (both PT 100 and PTC) Two independent PIDs On - Off controlled cooling fan
AC
S55
0 ©
AB
B O
y. -
27
ACS550 – Performance Scalar control for easy start-up and multi-motor
applications Sensorless Vector providing very good performance
Step load response (Dynamic accuracy)Vector Control
00.10.20.30.40.50.60.70.80.9
150 750 1500
Speed [rpm]
Stiff
ness
[%s]
ACS550
Competitor A
Competitor B