Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality...

88
Polypropylene and PVDF MATERIALS Acid W Acid W aste Systems aste Systems Cat OFAW-091505 September 2005

Transcript of Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality...

Page 1: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Polypropylene

and

PVDF

MATERIALS

Acid WAcid Waste Systemsaste Systems

Cat OFAW-091505September 2005

Page 2: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

Introducing Orion Fittings 4

Installations 5

Acid Waste System Outline 13

Materials 15

No-Hub Systems 16

Rionfuse CF (clamp-free) Outline 19

No-Hub/Rionfuse Outline 20

Socket Fusion Outline 22

Pipe Dimensions 23

No-Hub/Plain End Dimensions 24

Large Diameter 31

Socket Fusion Dimensions 34

Floor Drain Dimensions 40

Physical Properties 44

Installing Drainage Systems 46

Support Spacing 49

Chemical Resistance Polypropylene 51

Chemical Resistance PVDF 57

Assembly Instructions 63

Cold Weather Assembly 63

No-Hub/Mech Joint Assembly 64

Rionfuse CF Assembly 66

Socket Fusion Assembly 70

Backwelding Guidelines 71

Submittals 72

UL 723/ASTM E84 Approval 77

Rionfuser Submittal 78

Floor Drain Submittal 79

Floor Cleanout Submittal 85

Terms & Conditions of Sale 86

Table of ContentsTable of Contents

2 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 3: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 3

All data, information, formulas, recommendationsand suggestions provided in this manual concerningthe use of our products are based upon tests anddata believed to be reliable. However, it is theuser's responsibility to determine the suitability forhis own use of the products described herein, basedon the actual conditions of use. Since the actualuse by others is beyond our control, no guarantee,expressed or implied, is made by Orion Fittings,Inc., as to the results to be obtained or to theeffects of such use, nor does Orion Fittings, Inc.assume any liability arising out of the use of theinformation herein. The information contained here-in can not be construed to be absolutely complete since additional information may be nec-essary or desirable when exceptional or particularcircumstances or conditions exist or because ofapplicable laws or government regulations.

Copyright 2005 Orion Fittings, Inc. Prepared byBrad Weisbond for Orion fittings, Inc.September, 2005 All rights reserved. Thisbrochure may not be reproduced in whole or in partor be reproduced, duplicated or captured by anyelectronic means without express written permissionby Orion Fittings, Inc.

Rionfuse CF (clamp-free)

No Hub Fittings

Floor Drains and Cleanouts No-Hub Systems

Socket Fusion Systems

Electrofusion Equipment

Acid Waste Piping Systems

Page 4: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

4 ORION FITTINGS, INC. Acid Waste Piping Systems

Introducing Orion FittingsIntroducing Orion Fittings

Orion Fittings was the first company inNorth America to injection mold a completeline of polypropylene fittings. Through years ofexperience, Orion has established its positionas the industry leader in providing the engi-neer, the contractor and the ultimate user withdrainage and pure water piping products ofunsurpassed quality.

There are many reasons for Orion’s envi-able position. However, none is more impor-tant than our team of experienced manage-ment and production personnel. Working inclose cooperation at our centrally located pro-duction facility, our people routinely demon-strate Orion’s total capability in the design andmanufacture of polypropylene and polyvinyli-dene fluoride (PVDF) acid waste, pure water

and neutralization systems. They draw on thecompany’s 30-plus years of experience in themanufacture of these products to performwhere others cannot: by producing innovativeproducts utilizing the latest technological mate-rial of the petro-chemical industry.

At Orion, performance means many things.Our own in-house fabrication and productionmachine shops produce custom orders quickly,accurately and within budget. Our total in-housecapability to design, build and maintain moldskeeps costs to a minimum. We are the onlymanufacturer to offer complete drainage sys-tems including pipe, fittings, traps, dilutiontanks, neutralization basins and sinks.

Page 5: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 5

Quality Orion acid waste and high purityproducts have been installed in thousands offacilities over the years. Listed here is but aportion of those installations.

Installations

Central Midwest Region

Abbott Laboratories, North Chicago, IL

Abbott Laboratories, Abbott Park, IL

Abbott Laboratories, Northbrook, IL

Adams Community Schools, Monroe, IN

Allied Bendix, Kansas City, MO

Alpena General Hospital, Alpena, MI

Anoka-Ramsey Comm. College, Anoka, MN

Bartlett High School, Bartlett, IL

Belton High School, Belton, MO

Bethany Hospital, Kansas City, KS

Bismarck State College, Bismarck, ND

Blue Valley High School, Johnson Co., KS

Blue Valley North High School, Overland Park, KS

Boeing-Engineering, Wichita, KS

Carleton College, Northfield, MN

Carmel Junior High School, Carmel, IN

Center Grove High School, Greenwood, IN

Children’s Hospital, St. Louis, MO

Cleveland Clinic, Health Science Bldg., Cleveland, OH

College of Lake City, Waukegan, IL

Crystal Lakes High School, Crystal Lakes, IL

Davis Besse Nuclear Power Plant, Toledo, OH

Denmark High School, Denmark, WI

Dixon High School, Dixon, IL

Installations

ORION

Page 6: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Dorsey Laboratories, Lincoln, NE

Draft Feeds, Huntington, IN

Eagle Community High School, Zionsville, IN

Eastbrook Middle School, Marion, IN

Edmond Central Mid. High School, Edmond, OK

Fairfield High School, Cleves, OH

Franklin College, Barnes Science Hall, Franklin, IN

Freeport High School, Freeport, IL

FSI Corp, Chaska, MN

Ft. Wayne Northside High School, Ft. Wayne, IN

Garden City Community College, Garden City, KS

Grand Island Junior High School, Grand Island, NE

Greater Detroit Resource Recovery, Detroit, MI

Hillard High School, Willard, OH

Indianapolis Public Schools, Indianapolis, IN

IVTC (New Technology Center) Terre Haute, IN

Kal-Sec Industries, Kalamazoo, MI

Kearney High School, Kearney, MO

Kellogg Company, Kalamazoo, MI

Kerr-Mcgee Tech Lab, Oklahoma, OK

Lansing School System, Lansing, MI

Life Source, Glenview, IL

Lockport High School, Lockport, IL

Longview Junior College, Lee’s Summit, MO

Loyola Med. Center-Cancer Research, Maywood, IL

M.S.U. Gilbert Hall, E. Lansing, MI

Mankato State University, Mankato, MN

Maple Woods Junior College, Kansas City, MO

Maternal & Child Health Care Facility, Ann Arbor, MI

Michigan Bio-Tech Research Facility, E. Lansing, MI

Midland W.W.T.P., Midland, MI

Munson Medical Center, Traverse City, MI

Muskegon Schools, Muskegon, MI

New Sullivan High School, Sullivan, IN

Norden Laboratories, Lincoln, NE

Northwest High School, Wichita, KS

Oklahoma State Hospital, Oklahoma City, OK

Oklahoma State University 21st Century Project,Stillwell, OK

Olathe Junior High School, Olathe, KS

Parke Davis Pharmaceutical, Ann Arbor, MI

Price Corporation, Holland, MI

Providence-St. Margaret Hospital, Kansas City, KS

Purdue University, Food Science Bldg., West Lafayette,IN

Purdue University, GeoScience Building, WestLafayette, IN

Roosevelt University, Schaumburg, IL

Rose Hulman, Moench Hall, Terre Haute, IN

Roudebush VA Medical Center, Indianapolis, IN

Santa Fe Research Facility, Topeka, KS

SC Johnson Lab, Racine, WI

Shawnee Mission Hospital, Overland Park, KS

Southeast Middle School, Kansas City, MO

St. Francis Energy Center, Wichita, KS

St. Ignatius HS, Chicago, IL

St. Johns Hospital, Detroit, MI

St. Joseph Hospital, Saginaw, MI

St. Lukes Hospital, Ann Arbor, MI

St. Mary’s College, Notre Dame, IN

St. Mary’s Hospital, Minneapolis, MN

St. Mary’s Hospital, Bourbonnais, IL

Streetor Community Hospital, Streetor, IL

Sun Prairie HS, Sun Prairie, WI

Theda Clark Lab, Neenah, WI

Tony’s Pizza, Salina, KS

University Hospital, Columbus, OH

University of Indiana, Cancer Research Center, Indianapolis, IN

University of Indiana, Jordan Hall, Bloomington, IN

University of Kansas Medical Center, Kansas City, KS

University of Michigan Hospital, Ann Arbor, MI

University of Michigan, Cancer & Geriatrics, Ann Arbor,MI

University of Michigan, CC Little, Ann Arbor, MI

University of Nebraska, Lincoln, NE

University of Oklahoma Energy Center, Norman, OK

University of South Dakota, Vermillion, SD

University of Southern Indiana, Health Science Bldg.,

6 ORION FITTINGS, INC. Acid Waste Piping Systems

Orion Fittings, Inc. Installations

Page 7: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Veterans Administration Hospital, Oklahoma City, OK

Veterans Administration Hospital, Sioux Falls, SD

Wichita State University, Wichita, KS

Woodstock Hospital, Woodstock, IL

Eastern RegionAccutest Patterson, S. Brunswick, NJ

Allied Chemical, Morristown, NJ

Amherst Sewage Treatment Facility, Amherst, NY

Apollo Ridge High School, Spring Church, PA

Apple Hill Medical Center, York, PA

Applegarth School, Monroe, NJ

Aroostock Medical Center, Presque Isle, ME

Binestone Water Treatment Plant, Hinton, WV

Blue Ridge Community College, Charlottesville, VA

Boston Globe, Boston, MA

Brown University, Providence, RI

Cake Hospital, New Brunswick, NJ

Carnegie Mellon University–Research Institute, Pittsburgh, PA

Charley Brothers Warehouse, New Stanton, PA

Chesapeake Circulation, West Point, VA

Children’s Hospital, Pittsburgh, PA

Ciba Geigy, Summit, NJ

City-County Building, Pittsburgh, PA

Cornell University, Olin Hall, Ithaca, NY

Danville Middle School, Danville, PA

Doctors Hospital, Richmond, VA

E.I. Dupont Experimental Station, Wilmington, DE

East Coast Distribution Center, Newport News, VA

Electro Optics Lab (Naval Research Center), Washington, D.C.

Emmanuel College, Boston, MA

Enseco Labs, Summit, NJ

Fairmont Hospital, Fairmont, WV

Ford Motor Company, Edison, NJ

Fort Drum Expansion, Watertown, NY

Frederick Douglass High School, Prince Georges Co.,MD

Freehold Schools, Freehold, NJ

Gardiner High School, Gardiner, ME

General Electric, Reston, VA

George Mason University, Fairfax, VA

Hannahman Hospital, Philadelphia, PA

Harvard University Medical Center, Cambridge, MA

Harwood Mill water treatment plant, Newport News, VA

HI Pure Chemical, Nazareth, PA

Howard University, Washington, D.C.

Indiana Learning Center, Johnstown, PA

Ithaca College, School of Communication,Ithaca, NY

Karns City Area High School, Karns, PA

Lahey Clinic, Burlington, MA

Lakeview School, Sharpsville, PA

Life Technology Bldg., Gaithersburg, MD

Logan Middle School, Logan, WV

Louden High School, Washington, D.C.

Louisa Country Middle School, Charlottesville, VA

Madison High School, Madison, ME

Massachusetts General Hospital, Boston, MA

Massachusetts Water Resource Authority, Boston, MA

Acid Waste Piping Systems ORION FITTINGS, INC. 7

Installations Orion Fittings, Inc.

Page 8: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Millersville University, Millersville, PA

Molecular Biology Lab, Princeton, NJ

MWRA Metropolitan, Boston, MA

Mylan Pharmaceutical, Morgantown, WV

N.I.H., Bethesda, MD

New Hampshire Psychiatric Facility, Concord, NH

North Shore Hospital, Manhassett, Long Island, NY

Odor Control Lab, Richmond, VA

Oxon Hill High School, Oxon, MD

Paint Branch High School, Silver Springs, MD

Pennsylvania Hospital, Philadelphia, PA

Pinkerton Academy, Derry, NH

Potomac School, McLean, VA

Princeton University, Chem. Lab, E-Quad, Princeton,NJ

Princeton University, Frick Labs, Princeton, NJ

Princeton University, Lewis Thomas Lab, Princeton, NJ

Quabbin Regional School, Barre, VT

Quince Orchard High School, Gaithersburg, MD

Rockefeller Institute, New York City, NY

Rockview Prison Hospital, Rockview, PA

Rodel Mfg. Plant, Newark, DE

Rutgers University, Rutgers BioLabs, Piscataway, NJ

Sander & Thomas, Rocky Hill, CT

Sibly Hospital, Washington, D.C.

Sidwell Friends, Fairfax, VA

Sloan Kettering Laboratory, New York City, NY

Smethport Area Elementary School, Smethport, PA

Smith-Kline Beecham, Philadelphia, PA

St. Albans High School, Washington, D.C.

Summit Middle School, Summit, NJ

Temple Hospital, Philadelphia, PA

Thomas Jefferson Hospital, Philadelphia, PA

U.S.D.A. Center for Disease Control, Plum Island, NY

University of Connecticut-Stanford Campus, CT

University of Maryland, College Park, MD

University of Pennsylvania, Mudd Building,Philadelphia, PA

University of Virginia, Gilmer Hall, Charlottesville, VA

University of Virginia, Jordan Hall, Charlottesville, VA

University of Virginia, Multi-story Bldg., Charlottesville,VA

Veterans Administration Medical Center, Altoona, PA

Veterans Administration Medical Center, Clarksburg,WV

West Branch High School, Chesapeake, VA

West Virginia Institute of Technology, Montgomery, WV

West Virginia Medical Center (Chiller Plant), Morgantown, WV

Wheeling College, Donahue Hall, Wheeling, WV

Williamstown High School, Williamstown, NJ

Winchester Hospital, Winchester, VA

Yale University, New Haven, CT

Western RegionAdams Co. High School, Adams County, CO

Alta High School, Las Vegas, NV

Arcala College Science Building, Arcala, CA

Auraria College, Denver, CO

Ball Aerospace, Westminster, CO

Barbara Davis Research Center, Denver, CO

Berthoud Hall Lab, Colorado School of Mines

Boeing Research, Renton, WA

Boyd Coffee, Portland, OR

Cenref Labs, Brighton, CO

Chevron Research Building, Richmond, CA

Colorado College, Chemistry, Colorado Springs, CO

Colorado State University, bio-radiology building, Ft. Collins, CO

Colorado State University, chemistry building, Ft. Collins, CO

Columbia Basin Community College, Science Lab,Pasco, WA

Cord Labs, Broomfield, CO

DEA/Treasury Building, San Francisco, CA

Decatur High School, Federal Way, WA

Denver Water Board – Marston Treatment Plant,Denver, CO

Douglas Co. High School, Douglas County, CO

8 ORION FITTINGS, INC. Acid Waste Piping Systems

Orion Fittings, Inc. Installations

Page 9: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

H & O Foods, Las Vegas, NV

Hallmark Circuits, Poway, CA

Hewlett Packard, Santa Clara, CA

Highlands Ranch Waste Water Treatment Plant #2,Highland Ranch, CO

Hybriteck, San Diego, CA

Idaho State University, College of Pharmacy, Pocatello,ID

La Cueva High School, Albuquerque, NM

Lakeside High School, Seattle, WA

Los Lunas High School, Los Lunas, NM

Martin Marietta, Denver, CO

Metro Water Quality Lab, Seattle, WA

Micro-Biological Laboratory-Dept. of Water Supply,Lihue, Kauai, HI

Mira Costa College, Cardiff, CA

National Jewish Hospital, Denver, CO

Naval Environmental Laboratory Facilities, PearlHarbor, HI

Northwest Hospital, Seattle, WA

Palm Desert High School, Palm Desert, CA

Palomar College, San Marcos, CA

Pojoaque High School, Pojoaque, NM

Public Health Hospital, Seattle, WA

Quidel Labs, San Diego, CA

Renal Medical Center, Las Vegas, NV

River Medical, San Diego, CA

Rocky Mountain Analytical, Arvada, CO

Salk Institute, La Jolla, CA

San Diego Police Department, crime lab, San Diego,CA

Sandia Labs, Livermoor, CA

Santa Fe High School, Santa Fe, NM

Solar Research Institute, Golden, CO

Stanley Lake High School, Jefferson Co., CO

State of Hawaii, Dept. of Health Laboratory Facilities,Honolulu, HI

Strategic Defense Facility, Sandia Base, NM

Sweetwater Waste Water Treatment Plant, San Diego,CA

Synergen Labs, Boulder, CO

Syntex Chemical, Boulder, CO

Syntex, Palo Alto, CA

Thornton Water Treatment Plant, Thornton, CO

University of California at Davis – Food & AgriculturalScience Building, Davis, CA

University of California at Irvine

University of California at Irvine, Nelson Research, Irvine, CA

University of California at Los Angeles

University of California at Riverside, Riverside, CA

University of California at San Diego – Science Lab, San Diego, CA

University of California at San Diego – Bonnie Hall, San Diego, CA

University of Idaho, Science Building, Moscow, ID

University of New Mexico (Valencia Campus), Tome,NM

University of Oregon, Eugene, OR

University of Southern California, Los Angeles

University of Washington Hospital, Seattle, WA

University of Washington, Dental Building, Seattle, WA

University of Wyoming, decontamination center,Laramie, WY

USDA, Large Animal Isolation Facility, Laramie, WY

Vista High School, Vista, CA

Washburn High School, Las Vegas, NV

Waste Water Treatment, Albuquerque, NM

Wemlinger Water Treatment Plant, Aurora, CO

Yellow Zone Water Treatment Plant, Castle Rock, CO

Southern RegionA. Maceo Smith High School, Dallas, TX

AAA High School, Tampa, FL

Alief 9th Grade Campus, Houston, TX

Amaco Lab, Texas City, TX

American Greeting Cards, Bardstown, KY

Arlington Junior High School, Arlington, TX

Athens High School, Athens, TX

Baptist Medical Center, Montgomery, AL

Baptist Regional Medical Center, Corbin, KY

Acid Waste Piping Systems ORION FITTINGS, INC. 9

Installations Orion Fittings, Inc.

Page 10: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Brookwood High School, Atlanta, GA

Casnerr Heights School, El Paso, TX

Chase Brass & Copper Corp., Shelby, NC

Clay County Middle School, Orange Park, FL

Clemson University Biological Science Building,

Clemson, SC

Clemson University Chemistry Building, Clemson, SC

Coca-Cola Bottling Plant, Knoxville, TN

Coca-Cola, Atlanta, GA

Conroe Medical Center, Conroe, TX

Conway High School, Conway, SC

Cordia Corp., Miami Lakes, FL

Coweta County High School, Newnan, GA

Dallas Ind. School District, Dallas, TX

Dallas Middle School, Dallas, TX

Deer Valley High School, Glendale, AZ

Diamond Hill Jarvis High School, Ft. Worth, TX

Duke University Hospital North, Durham, NC

Duke University, Clinical Science Building, Durham, NC

Duval County Science Classrooms, Jacksonville, FL

E System, St. Petersburg, FL

E.I. Dupont, Research Triangle, NC

Easley Hospital, Easley, SC

Elmwood Medical Center, Metairie, LA

Emory University, Atlanta, GA

Fairview Middle School, Fairview, TN

FAU Science Building, Boca Raton, FL

Fina New Tech Lab, La Porte, TX

Florida Gulf Coast University, Ft. Myers, FL

Frito-Lay, Atlanta, GA

Gaither High, Tampa, FL

General Electric Corp., Wilmington, NC

Georgia Tech University, Atlanta, GA

Germantown Community Hospital, Germantown, TN

Grissom High School, Huntsville, AL

Groesbeck High School, Groesbeck, TX

H.M. Laundrum Middle School, Houston,TX

Harlingen West Campus, Harlingen, TX

Harriman W.W.T.P., Harriman, TN

Hermann Heart Institute, Houston, TX

High school science rooms, El Paso, TX

Highland Clinic, Shreveport, LA

Hockaday School, Dallas, TX

Homer Hospital, Homer, LA

Houston Comm. College, Stafford, TX

Humana Hospital, N. Miami Beach, FL

Hunters Lane High School, Nashville, TN

IBM Research Facility, Charlotte, NC

Indian River Medical Center, Vero Beach, FL

Iredell Memorial Hospital, Statesville, NC

Irmo High School, Irmo, SC

Italy High School, Italy, TX

Jefferson High School, Jefferson, TX

Judson High School, Converse, TX

Karns High School, Knoxville, TN

Kimberly-Clark, Atlanta, GA

Lake Brantley High School, Longwood, FL

Lake Wales Hospital, Lake Wales, FL

Land O’ Lakes High School, Land O’ Lakes, FL

Lely High School, Naples, FL

Louisiana State University Nursing School, Boyce, LA

10 ORION FITTINGS, INC. Acid Waste Piping Systems

Orion Fittings, Inc. Installations

Page 11: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Mary Black Hospital, Spartanburg, SC

Memorial Hospital, Jacksonville, FL

Memorial Middle School, Houston, TX

Methodist Community Medical Center,Sugarland, TX

Middle School North, Shreveport, LA

Middle School, Tampa, FL

Mission Junior High School, Mission, TX

Moses Molina High School, Dallas, TX

NASA Launch Facility, Cape Canaveral, FL

North Carolina State, State University, Raleigh, NC

North Dallas High School, Dallas, TX

North Shore High School, Houston, TX

Northside Hospital, GA

Northwood High School, Boyce, LA

Palm Beach Atlantic College, W. Palm Beach, FL

Palm Beach County Community College, W. PalmBeach, FL

Palo Alto College, San Antonio, TX

Pensacola Jr. College, Pensacola, FL

Peoria Elementary School, Peoria, AZ

Pepperidge Farm Labs, Lakeland, FL

Picayune High School, Pontotoc, MS

Pinkneyville High School, Gwinnett County, GA

Police Headquarters satellite fire facility, Phoenix, AZ

Prescott High School, Prescott, AZ

Providence Hospital, Charlotte, NC

Providence Hospital, Columbia, SC

Providence Hospital, Mobile, AL

Queen Creek Vocational Center, Queen Creek, AZ

R.J. Reynolds Tobacco Co. Research Building,Winston-Salem, NC

Red Mountain High School, Mesa, AZ

Roland Park Middle School, Tampa, FL

Rubbermaid Facility, Phoenix, AZ

Ruston High School, Ruston, LA

School S-6, W. Palm Beach, FL

Science Lab, Gulfport, MS

Science Lab, Ocean Springs Junior High School, Ocean Springs, MS

Seagroves High School, Seagroves, TX

Sears Auto Center, Riviera Beach, FL

Shands Hospital, Gainesville, FL

Smith-Kline Beecham Labs, Tampa, FL

Southwest Wastewater Treatment Plant, Houston, TX

Spring Lite Bottling Co., Miami, FL

SRP Service Center, Tolleson, AZ

St. Joseph Hospital, Houston, TX

St. Joseph Hospital, Tampa, FL

Stone Mountain High School, Atlanta, GA

Sun Sentinel Bldg., Deerfield Beach, FL

Texas Instruments, Sherman, TX

Texas Tech School of Medicine, Lubbock, TX

Tuskegee University, Chappey James ScienceResearch, Tuskegee, AL

Tuskegee University, farm mechanization center, Tuskegee, AL

U.S. Army ammunition plant, Shreveport, LA

Union Carbide, Inc., Research Triangle, NC

University Community Hospital, Tampa, FL

University of Alabama, Birmingham, AL

University of Alabama, Energy Mineral ResearchBuilding, Tuscaloosa, AL

University of Arizona Laboratory & Central OfficeBuilding, Tucson, AZ

University of Georgia, Athens, GA

University of Louisville School of Dentistry, Louisville,KY

University of South Carolina, Charlotte ChemistryBuilding, Charlotte, SC

University of South Carolina, Earth & Water ScienceBuilding, Columbia, SC

University of South Florida Cancer Research Center, Tampa, FL

University of South Florida Eye Institute, Tampa, FL

University of South Florida Health Services, Tampa, FL

Valley View High School, Canyon, TX

Veterans Administration Hospital, Columbia, SC

Veterans Administration Building, Houston, TX

Veterans Administration Education Building,Shreveport, LA

Veterans Administration Hospital, Big Spring, TX

Acid Waste Piping Systems ORION FITTINGS, INC. 11

Installations Orion Fittings, Inc.

Page 12: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Wake Forest University, Winston-Salem, NC

Wal-Mart Distribution Center, Brookhaven, MS

West Hall High School, Gainesville, GA

Winn-Dixie Distribution Center, Montgomery, AL

Winnfield School, Winnfield, LA

InternationalAmerican Embassy, Chittagong, Bangladesh

AT&T Microelectric Manufacturing Facility, Madrid,Spain

Carolina Area Hospital, Carolina, Puerto Rico

Esculea de Medicina de Puerto Rico, Rio Pedras,Puerto Rico

Hospital Alilo de Damas, Ponce, Puerto Rico

Hospital Auxilo Mutuw, Hato Rey, Puerto Rico

Hospital Gandara, Ponce, Puerto Rico

Inter American University, Rio Piedras, Puerto Rico

King Abdul Aziz University, Jedda, Saudi Arabia

King Fahad Air Base, Taif, Saudi Arabia

King Saud University, Riyadh, Saudi Arabia

McCaw Labs, Sabana Grande, Puerto Rico

Pepsi Cola Consolidated Lab, San Juan, Puerto Rico

Ponce District Hospital, Ponce, Puerto Rico

Psychiatric Hospital, Rio Piedras, Puerto Rico

Smith Kline & French, Guayama, Puerto Rico

U.S. Customs, San Juan, Puerto Rico

12 ORION FITTINGS, INC. Acid Waste Piping Systems

Orion Fittings, Inc. Installations

Page 13: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

A Choice of Materials and JoiningSystemsFor engineers and contractors, Orion

drainage systems molded from polypropylene,flame retardant Proxylene®, and Kynar®brand of Polyvinylidene fluoride (PVDF) have been the acid wasteproducts they’ve specified and installed foryears. Why? Because they know the cost ofdependable Orion drainage systems can befar less than competitive corrosion resistantmaterials. And because they have a choice ofmaterials and joining methods it’s easy to cus-

Acid WastePiping

Acid WastePiping

tom-design systems to meet their particularneeds. It’s a choice that is unequalled in theplumbing industry.

Orion offers the most complete line of fit-tings and pipe. This includes the widestassortment of sizes and drainage patternmolded geometries of any acid waste pipingsystem available today. Fittings are availablein three different joining systems—socketfusion, No-Hub/Plain End and Rionfuse ClampFree® electrofusion in two different materials:flame retardant Blueline polypropylene or forextreme applications or where fire is an issue,Super Blue PVDF (Polyvinylidene Fluoride).

Acid Waste Piping Systems ORION FITTINGS, INC. 13

Page 14: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

This acid waste piping system also has allthe accessories necessary to offer a truly com-plete plumbing system including finished floorcleanouts, floor drains, sinks, neutralizationtanks and monitors.

When it’s time to install a corrosion resistantdrainage system, look to the company that canhandle all your needs, from the sink to the finalhook-up and everything in between. Look toOrion.

Resins• Flame-retardant polypropylene (proxylene)

• Polyvinylidene fluoride (PVDF)

Joining Systems With the broadest range of joining systems

in the industry, whatever your needs are, youcan count on Orion to provide the exact systemyou need to meet your requirements.

• No Hub (Mechanical joint)

• Rionfuse Clamp Free® electrofusion

• Socket Fusion

Pipe • Standard: Schedule 40 (optional: Schedule

80)

• 1-1/2”–12" sizes available

• Blueline flame-retardant; non-flameretardant brownline; PolyvinylideneFluoride PVDF

Fittings• Schedule 40

• Blueline flame-retardant; PVDF

• Wide variety of fittings

• 11⁄2"–6" molded sizes available

• 8"–12" fabricated sizes available

• sizes above 12" can be fabricated

AccessoriesTo complete your corrosion resistant

drainage system, Orion offers a complete lineof laboratory accessories, including: sinks,tanks, drains and other accessories.Information on these accessories can be foundin Orion’s tank and accessories catalogs.

14 ORION FITTINGS, INC. Acid Waste Piping Systems

Monitors Floor drains & cleanouts Laboratory sinks Tanks

Orion Fittings, Inc. Acid Waste Piping Systems

Page 15: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Polypropylene

BluelineAll Orion joining systems are available mold-

ed from proxylene blueline resin. Proxylene (anOrion trade name) is a fire retardant, thermo-plastic material with excellent resistance tomost common organic and mineral acids, theirsalts, strong and weak alkalis and most organ-ic chemicals.

Proxylene is compounded of polypropylene Type II copolymer with fire retardant additives.Polypropylene is a thermoplastic material char-acterized by a stable and highly orderedsteroregular molecular chain. This structureproduces a rigid material with good strengthand aging properties.

Proxylene qualifies for UnderwritersLaboratory certification of V-2 when testedunder UL Subject 94 in thickness of .150 andover. Based on parameter of ASTM D635,Proxylene also meets established industry cri-teria for self-extinguishing. Proxylene qualifiesunder ASTM D2843 smoke chamber test witha maximum value of less than 50. It also doesnot contain toxic gases as do PVC and otherpetroleum-based plastics.

MaterialsMaterials

Acid Waste Piping Systems ORION FITTINGS, INC. 15

ORION

BrownlineBrownline pipe offers all the advantages of

Blueline Proxylene in installations where non-fire retardant materials are acceptable.

Kynar® brand PolyvinylideneFluoride (PVDF) PVDF is the most resistant of all thermoplas-

tics. It offers superior chemical resistance tomany solvents, acids, bases and halogens. It isdesigned for extra tough applications whereplastic may not have been considered before.

It has been certified to meet ASTM E-84 andUL 723 standards for flame spread and smokegeneration. The certification means that for thefirst time PVDF piping systems, whenapproved, can be used safely in areas such asair plenums where typically local codes haveprohibited use of plastic pipe due to fear of fire.

In addition to being non-combustible, PVDFis able to maintain much of its strength andchemical resistance within a broad temperaturerange of –40°F to 285°F.

Sizes from 112" to 12" are offered. Single wall

and double wall configurations are available.Molded drainage pattern fittings are alsooffered.

Page 16: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

16 ORION FITTINGS, INC. Acid Waste Piping Systems

NO-HUB-Plain EndJoiningSystems

Orion No-Hub/Plain End Joining System

The Drainage System Engineers and ContractorsChoose

Orion is recognized as an industry leader in themanufacture of economical, easy-to-install No Hubdrainage systems.

Our exclusive No-Hub coupling greatly simplifiesinstallation by eliminating the need for expensive toolssuch as torque wrenches, power packs and specialtightening tools. One easy-to-use, inexpensive pipegrooving tool and standard tool box hand tools are allthat are needed to produce tight, leak-free jointsevery time. Thus, significant savings can be realizedby specifying and installing Orion Polypropylene orPVDF drainage systems assembled with a mechani-cal joining system.

Check the many other features of the No-Hubdrainage system. You’ll see why it has become afavorite of engineers and contractors in hundreds ofinstallations in the United States, Canada and PuertoRico.

Features• Fast and easy installation means lower labor

cost

• All fittings pre-grooved at factory

• 10' length standard (20' sections available)All pipe factory grooved

• No heat or hot water required

• Easily assembled with ordinary hand tools

• Strong, unbreakable

• Easy to clean out and maintain (made withmaintenance people in mind)

• Reusable and easy to move and change.Ideal when systems modifications are calledfor in remodeling projects. Mechanical Jointsystems are adaptable for use with othermaterials, including PVDF.

• Stainless steel outer coupling

• No metal in joint

• Suitable for below ground applications

• Easy fabrication of complex sub-assemblies.

Page 17: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Recommended specification for Orion No-Hub/Plain End Blueline corrosive wastedrainage system.

The corrosive waste drainage system, conforming to ASTM F1412, shall be Orion bluelineflame-retardant polypropylene pipe and fittings. The pipe and fittings shall be joined using theOrion No-Hub/Plain End coupling. The pipe shall be supplied in factory grooved 10-ft. length.Fittings are to meet or exceed Schedule 40 dimensions. Each Orion coupling shall have 300series stainless steel outer band and 5⁄16" bolts, nuts and washers plated to meet a 100-hour saltspray test per ASTM B117. The polypropylene material shall conform to ASTM D4101.

Recommended specification for Orion No-Hub/Plain End Super Blue (PVDF)corrosive waste drainage system.

The corrosive waste drainage system, conforming to ASTM F1673, shall be Orion’s Super BluePVDF (Polyvinylidene Fluoride) pipe and fittings. The pipe and fittings shall be joined using theOrion No-Hub/Plain End coupling. The pipe shall be supplied in factory grooved 10-ft. lengths.Fittings are to meet or exceed Schedule 40 dimensions. Each Orion coupling shall have 300series stainless steel outer band and 5⁄16" bolts, nuts and washers plated to meet a 100-hour saltspray test per ASTM B117. The PVDF material shall conform to ASTM D3222. Pipe shall bemarked with UL to indicate compliance with UL723 (ASTM E84).

Sample Specifications Orion Fittings, Inc.

Acid Waste Piping Systems ORION FITTINGS, INC. 17

Page 18: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Proven Reliability........ORION NO HUB SYSTEMS

• Requires Pipe “Pups” for fitting tofitting Connections.

• Requires Petroleum Jelly.• May Require Periodic TighteningOf Nuts.

• Not Recommended For ConcealedAreas.

• Requires Pipe “Pups” for fitting tofitting Connections.

• Multiple Joint Components.

• Difficult To Fit In Walls.

• Requires Pipe “Pups” for fitting to

fitting Connections.• May Require Periodic Tightening

Of Nuts.

Plastic “Mechanical Joint” Fitting Plastic “Mechanical Joint” Fitting Plastic “Mechanical Joint” Fitting

• Proven “No-Hub” Design

• Quick & Easy Installation

• Light Weight

• High Chemical Resistance

Orio

n “

Orio

n “No-H

ub

No-Hub””

The Nex

t Gen

erat

ion In

Plast

ic A

cid W

aste

Pip

ing

Syste

ms

18 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 19: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

Orion’s state-of-the-art joining system forpolypropylene provides unsurpassed ease ofinstallation and joint strength.

When ease of installation is a prime consid-eration, there’s really only one joining systemyou should consider . . . the Rionfuse CF®

(Clamp Free) electrofusion system.The electrofusion coil is made of heavy

gauge wire that is molded right into theRionfuse coupling. Each coupling is manufac-tured using state of-the-art robotic technologyresulting in a system that is made to the high-est possible standards. This system providesa joint strength that has never before beenseen in this industry. Above all, unlike ourcompetition, the rionfuse CF joint does notrequire clamping devices at any time duringinstallation. Each wire terminal is protectedwith shrouds, which means couplings do notarrive damaged. The serpentine wire configu-ration and heavy gauge stainless steel wiremeans strong durable coils that won’t break.

Check the many features Rionfuse CF®

offers. You’ll see why it quickly has become afavorite of engineers and contractors in hun-dreds of installations in the United States,Canada, Mexico, and around the world.

Rionfuse CF®

(Clamp-Free)ElectrofusionSystem

Rionfuse CF®

(Clamp-Free)ElectrofusionSystem

Features• No Clamps required

• Fast and easy installation means lower cost

• Multiple jointing capabilities and both sides of couplingsfuse at the same time, saving labor

• Positive joints are made in just a few minutes

• Uses same plain end fittings as our No-Hub system

• 10' lengths standard (20' sections available)

• Easily assembled with ordinary hand tools & Rionfuser®

electrofusion machine

• Strongest joint in the industry.

• Non-corrosive polypropylene provides excellent resistanceto a wide variety of chemicals and acids

• “State of the art” joining system

• Joining machine tough and reliable, joint after joint

• Available in sizes of 11/2” - 12”

Recommended specification for Orion Rionfuse®Blueline corrosive waste drainage system.

The corrosive waste drainage system conforming toASTM F1412, shall be Orion’s Blueline flame retardant pipe& fittings. Pipe and fittings shall be joined using the OrionRionfuse® joining machine. Pipe shall be supplied in 10-ft.lengths. Fittings shall meet or exceed Schedule 40 dimen-sions. Each fitting socket shall be supplied with a moldedRionfuse CF ® coil, of heavy gauge resistance wire. TheRionfuse® joint shall conform to ASTM F1290.

Acid Waste Piping Systems ORION FITTINGS, INC. 19

Page 20: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Y O U M A K E Y O U M A K E

ORION NOORION NO-- HHUB OR........ UB OR........

NO-HUB BENEFITS

•Easy Fitting-to-Fitting Connections

(no pipe in between)

•Time Tested and Proven No-Hub Design

•Quick and Easy Installation and reliable

performance

•Available in Polypropylene and PVDF

•PP and PVDF are Easily Interchangeable

•Fittings Can Easily be Dis-assembled and

Re-assembled Ideal for systemmodifications

•Easy Assembly with Ordinary Hand Tools

•High resistance to lateral loading, making

No-Hub excellent for buried applications

SSSSaaaammmmeeee NNNNoooo----HHHHuuuubbbb FFFFiiii tttt tttt iiiinnnngggg uuuussssiiiinnnngggg yyyyoooouuuurrrr

Proven No-Hub Design

Both systems use the

• No Need for 2 Fitting Inventories• Same Fitting Lay Lengths - Regardless of Joining Type

ie: same system design for both joining methods

20 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 21: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

T H E C H O I C E ! T H E C H O I C E !

..........RIONFUSE CF ..........RIONFUSE CF

RIONFUSE CF BENEFITS

•No Clamps required

•Strongest Joint in the industry

•Proven Joint Design

(similar to gas fittings)

•Multiple Joint Capabilities

•Fusion Indicators - to show when a joint is

complete

•Coil is Integral to Joint - no separate parts

•Continuous Coil throughout Coupling - both

sides fuse at the same time saving installation

time.

•Available in Polypropylene and PVDF

CCCChhhhooooiiiicccceeee ooooffff JJJJooooiiiinnnniiiinnnngggg MMMMeeeetttthhhhoooodddd

Strongest Electrofusion Joint Available

SAME No-Hub Fittings

• Easy Transition From No - Hub to Riofuse CF• Same System Can Be Used Above and Below Ground

(patent pending)

Acid Waste Piping Systems ORION FITTINGS, INC. 21

Page 22: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

The Time Tested Drainage Systemfrom OrionSocket fusion drainage systems are

durable, strong and tamper-proof. Heat fusionforms a complete hermetically sealed systemwhich makes socket fusion systems ideal forsevere usage applications.

Socket fusion type pipe and fittings arejoined by heat fusing the polypropylene orpolyvinylidene fluoride material with an Orionthermostatically controlled heat tool. In a semi-molten state, pipe and fittings are easily joinedto form a strong and permanent sealed joint.PVDF fittings and pipe are also available inthe socket fusion joining system. However,because PVDF and PP are dissimilar materi-als they will not fuse together.

Check these outstanding features ofOrion’s time tested socket fusion systems.

Features• Fast and easy to install. Only 15–35

seconds per joint is all it takes after theheat-fusing tool has warmed up

• Several models of economical heat fusingtools are readily available from Orion

• Completely sealed for strength anddurability

• Forms true hermetically sealed joint

• All identical material, no electrolysis, nometal in joint

• Ideal for severe use applications

• Orion fusion systems meet ASTM D2657standards in their entirety

SocketFusionSystem

SocketFusionSystem

Recommended specification for OrionBlueline socket fusion corrosive wastedrainage system.

The corrosive waste drainage system, con-forming to ASTM F1412, shall be Orion’sBlueline flame retardant pipe and fittings. Pipeand fittings shall be joined using the Orionsocket fusion system conforming to ASTMD2657. The pipe shall be supplied in 10-ftlengths. The fittings shall meet or exceedSchedule 40 dimensions. The polypropylenematerial shall conform to ASTM D4101.

Recommended specification for OrionPVDF socket fusion corrosive wastedrainage system.

The corrosive waste drainage system, con-forming to ASTM F1673, shall be Orion’sSuper Blue PVDF (Polyvinylidene Fluoride)pipe and fittings. The pipe and fittings shall bejoined using the Orion socket fusion systemconforming to ASTM 2657. The pipe shall besupplied in 10-ft. lengths. The fittings shallmeet or exceed Schedule 40 dimensions. ThePVDF material shall conform to ASTM D3222.Pipe shall be marked with UL Classified toindicate compliance with UL723 (ASTM E84).

22 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 23: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems DimensionsAvailable in Polypropylene or PVDF

Weight per Stick (lbs) Sticks per BundleSchedule 40 Average OD Wall Thickness PP PVDF PP PVDF

1½ 1.900 0.145 4 8.8 10 102 2.375 0.154 6 12.5 10 53 3.500 0.216 10 18 5 34 4.500 0.237 15 28 3 16 6.625 0.280 24 48 1 18 8.625 0.322 42 N/A 1 N/A*10 9.842 0.300 65 N/A 1 N/A*12 12.400 0.380 91 N/A 1 N/A*14 13.976 0.430 115 N/A 1 N/A

Weight per Stick (lbs) Sticks per BundleSchedule 80 Average OD Wall Thickness PP PVDF PP PVDF

1½ 1.900 0.200 6 9 10 52 2.375 0.218 7 12 10 53 3.500 0.300 13 25 5 34 4.500 0.337 18 34 3 16 6.625 0.432 29 58 1 1**8 8.625 N/A 55 N/A 1 N/A**10 10.750 N/A 96 N/A 1 N/A**12 12.750 N/A 113 N/A 1 N/A

Weight per Stick (lbs) Sticks per Bundle

* denotes “Nominal” OD size. Actual pipe manufactured to class 45 psi metric standards

** denotes Special run required-not a standard stock item. Contact Orion for delivery times.

Pipe

O.D. (Outside Diameter)

Wall Thickness

Dimensions are in inches unless noted otherwise. Dimensional tolerance = ±⅛”

www.orionfittings.com Acid Waste 8

Page 24: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Fitting Dimensions No-Hub/Plain EndAvailable in Polypropylene or PVDF

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ⅛” 1¾” 4.86 8.692 ⅛” 2⅛” 5.43 11.403 ⅜” 3” 9.33 19.594 ¼” 3⅜” 13.25 27.836 ⅜” 4⅝” 23.75 49.87

CLSCoupling

A

B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 1½” 2.70 5.672 1½” 2.62 5.503 2⅜” 12.75 26.784 2¾” 19.46 40.876 4⅛” 30.25 63.53

45E1/8 Bend

A

A

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 2⅝” 2⅝” 2.45 5.152 3½” 3½” 3.73 7.833 4¾” 4¾” 16.83 35.344 5⅜” 5⅜” 18.58 39.026 9⅞” 9⅞” 61.45 129.00

90E1/4 Bend

A

B

90ELong Sweep

A

B

WEIGHT WEIGHTSize: A B C D E PP PVDF

1½ 2⅞” 2⅞” 4.2 9.62 3⅜” 3⅜” 5.8 12.33 5” 5” 20.8 46.24 5⅞” 5⅞” 40.6 84.8

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 4¾” 3⅜” 2⅝” 4.30 9.032 5½” 4¼” 3¼” 7.68 16.133 7⅝” 6⅛” 4¼” 18.08 37.974 10¼” 7⅛” 5¾” 34.93 73.35

90TSanitary Tee

A

B

C

*Weights are approximate, in ounces.

R90TReducing Sanitary Tee

A

B

C

WEIGHT WEIGHTSize: A B C D E PP PVDF

2x1½ 5⅛” 2¾” 2⅝” 4.75 10.013x1½ 6¾” 3½” 3⅝” 10.22 22.003x2 6¾” 3⅝” 3⅝” 10.70 22.404x1½ 10⅛” 8¼” 5¾” 35.18 71.604x2 10⅛” 6½” 5¾” 34.86 76.504x3 10⅛” 6¾” 5¾” 34.77 69.60

Dimensions are in inches. Dimensional tolerance = ±⅛”

9 ORION Kansas City, Kansas 66117 FAX 1 800-777-1653

Page 25: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E PP PVDF

2x1½ 7¼” 5⅝” 6⅜” 8.70 17.603x1½ 6¼” 5⅝” 5⅝” 13.82 27.603x2 8” 6⅜” 7¼” 19.55 40.104x1½ 8½” 7½” 8¼” 20.93 42.604x2 8⅝” 7” 7⅝” 20.70 41.804x3 10⅛” 9” 9” 33.10 66.806x2 19⅞” 11” 15⅞” 95.81 190.606x3 19⅞” 11” 15” 102.20 205.806x4 19⅞” 11⅝” 15⅜” 109.30 220.70

RLTYReducing Long Turn Wye

A

B

C

No-Hub/Plain End Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces.

WEIGHT WEIGHTSize: A B C D E PP PVDF

2x1½ 7¼” 2¼” 5” 6.75 14.213x1½ 7¼” 1½” 5¾” 10.43 11.803x2 8” 2½” 6½” 17.33 35.204x1½ 8⅜” 1⅞” 7⅝” 19.25 40.624x2 8½” 2⅝” 6¾” 17.88 36.804x3 10⅛” 2½” 7¾” 24.45 50.106x2 19⅞” 6⅝” 12⅝” 94.88 189.606x3 19⅞” 6⅝” 12⅝” 93.56 186.706x4 19⅞” 6⅝” 13” 94.49 189.60

R45YReducing Single Wye

A

B

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6⅜” 4⅞” 5½” 5.34 11.212 7¼” 5¾” 6½” 10.30 21.633 9⅛” 8⅜” 8½” 29.18 61.284 11⅛” 10” 9⅞” 35.78 75.146 19⅞” 13⅞” 16” 132.36 278.00

LTYLong Turn Wye

A

B

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6¼” 4” 2⅜” 8.60 18.062 8¼” 5⅜” 3” 14.87 31.233 8¾” 6⅛” 2⅝” 29.60 62.164 11¾” 8” 3¾” 37.43 78.606 19⅞” 11½” 6½” 147.62 310.00

D45YDouble Wye

AB B

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6⅜” 2” 4⅜” 3.74 7.852 7¼” 2¼” 5” 7.63 16.023 9⅛” 2⅝” 7½” 20.53 43.114 11⅛” 3⅜” 8¾” 30.80 64.686 19⅞” 6½” 11⅜” 99.96 209.90

45YSingle Wye

A

B

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 1” 7⅞” 2⅛” 3⅝” 4.85 10.192 1” 5½” 2⅛” 3½” 8.75 18.383 1⅜” 10¾” 2⅞” 4⅝” 22.73 47.734 1⅝” 12¼” 3½” 5⅞” 19.93 41.856 2⅛” 20¼” 9⅝” 13⅜” 68.61 144.10

counter-sunk plug included

COTClean Out Tee

A

A

B

B/2

CD

Dimensions are in inches. Dimensional tolerance = ±⅛”

www.orionfittings.com Acid Waste 10

Page 26: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Fitting Dimensions No-Hub/Plain EndAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces .

WEIGHT WEIGHTSize: A B C D E PP PVDF

2x1½ 8⅜” 5⅜” 3” 14.33 29.703x1½ 6¼” 5¼” 1½” 12.18 26.303x2 8¾” 6⅛” 2⅞” 19.60 38.704x1½ 8⅜” 7¾” 1⅞” 26.14 53.804x2 8⅜” 7⅞” 1⅞” 23.10 48.204x3 10⅛” 7⅜” 2¾” 30.03 60.906x2 19⅞” 12⅝” 6⅜” 122.90 250.606x3 19⅞” 12½” 6⅜” 104.36 210.706x4 19⅞” 12⅞” 6⅜” 106.22 215.70

RD45YReducing DoubleWye

AB B

C

WEIGHT WEIGHTSize: A B C D E PP PVDF

2x1½ 8⅜” 5¾” 7¼” 18.37 37.803x1½ 6¼” 5¾” 5⅝” 15.80 34.603x2 8¾” 6⅜” 7⅜” 23.86 48.704x1½ 8⅜” 7½” 7¾” 27.69 37.604x2 8⅜” 7⅝” 7¾” 29.12 83.604x3 10⅜” 8½” 8¾” 47.33 97.606x2 19⅞” 11” 15⅞” 108.86 218.006x3 19⅞” 12⅝” 16⅜” 113.46 230.716x4 19⅞” 13” 16⅜” 132.98 268.70

RDLTYReducing DoubleLong Turn Wye

A

B B

C C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6⅜” 4⅜” 5⅛” 10.26 21.552 8¼” 5” 6⅜” 16.23 34.083 8¾” 7⅞” 7¾” 46.90 98.494 11⅝” 9½” 10¼” 64.19 134.806 19⅞” 13⅜” 15⅝” 181.86 381.90

DLTYDouble LongTurn Wye

A

B B

C C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ⅞” 2⅛” 1.12 2.352 ¾” 2” 1.38 2.903 1¼” 3” 3.85 8.084 1¼” 3” 5.38 11.306 2” 4⅜” 15.30 32.13

MAMale Adapter

A

B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ⅞” 2⅛” 1.57 3.302 ¾” 2” 2.94 6.173 1¼” 3” 6.76 14.204 1¼” 3” 11.88 24.956 2” 4⅜” 25.41 53.36

COACleanout Adapter

AB

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ⅞” 2⅛” 1.12 2.352 ¾” 2” 1.90 3.993 1¼” 3” 4.93 10.354 1¼” 3” 7.78 16.346 2” 4⅜” 17.48 36.71

FAFemale Adapter

A

B

Dimensions are in inches. Dimensional tolerance = ±⅛”

11 ORION Kansas City, Kansas 66117 FAX 1 800-777-1653

Page 27: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 2¼” 2.06 4.332 2⅝” 3.16 6.643 3¼” 6.80 14.284 3⅜” 12.53 26.316 5¼” 26.55 55.76

CAPCap

A

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 3⅛” 1⅛” 2¼” 1.96 4.122 3⅜” 1⅛” 2⅝” 3.60 7.563 4⅝” 1⅛” 3¾” 8.60 18.064 5⅜” 1⅛” 4¾” 13.62 28.60

DADuriorn X MJ Adapter

A

B

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ⅜” 1” 1.57 .952 ¾” 1” 1.02 2.143 ¾” 1⅛” 1.83 3.844 ¾” 1⅛” 4.10 8.616 1” 1⅜” 7.93 16.65

CPCCleanout Plug

B A

ORION KCK USA

M

No-Hub/Plain End Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces.

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x1½ 2⅛” 1.52 3.193x1½ 2½” 4.11 8.633x2 2½” 3.34 7.014x1½ 4¼” 5.98 12.564x2 2¾” 5.03 10.564x3 3” 5.35 11.246x2 5⅜” 19.34 40.616x3 5½” 20.10 42.216x4 5¾” 20.08 42.17

RBReducing Bushing

A

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6” 2.73 5.732 6” 3.60 7.563 6” 7.80 16.384 6” 10.96 23.026 6” 19.60 41.16

DHADuriorn Hub X MJ Adapter

A

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6” 2.73 5.732 6” 3.60 7.563 6” 7.80 16.384 6” 10.96 23.026 6” 19.60 41.16

CIACast Iron Hub X MJ Adapter

A

Dimensions are in inches. Dimensional tolerance = ±⅛”

www.orionfittings.com Acid Waste 12

Page 28: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Fitting Dimensions No-Hub/Plain EndAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces.

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6½” 5⅛” 4” 5” 3½” 11.73 24.632 7¾” 5⅝” 5” 5½” 3⅝” 18.73 39.33

UTPFull drop unionP-trap

A

B

C

D E

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 8⅛” 5” 2⅝” 13.10 27.512 10⅛” 5½” 2¼” 22.73 47.73

UTPSS Trap

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 9” 5⅛” 4” 3½” 13.85 29.092 10½” 5½” 5” 3½” 19.10 40.11

UTRRunning Trap

A

B

C

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 6⅝” 2⅝” 4” 7.01 14.722 9⅛” 3⅜” 5⅝” 11.76 24.703 12¾” 4¾” 8” 42.29 88.814 15” 5⅝” 9½” 58.59 123.006 21¼” 7⅞” 13⅜” 192.25 403.70

RBPP Trap

A

BC

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ½” 2½” 2.50 5.252 ¾” 4” 4.66 9.79

RLNSSink Tail Piece Adapter

AB

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 8¾” 2¾” 2” 9.09 19.092 11⅜” 3½” 2¼” 15.72 33.013 16⅛” 4¾” 3⅜” 55.02 115.504 18⅞” 5⅝” 3⅞” 77.17 162.10

RBPSS Trap

A

B C

Dimensions are in inches. Dimensional tolerance = ±⅛”

13 ORION Kansas City, Kansas 66117 FAX 1 800-777-1653

Page 29: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ ½” 12¾” 7.33 15.392 ¾” 13⅝” 9.80 20.58

RLNS12Sink Tail Piece Extension

BA12

M

No-Hub/Plain End Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 2¼” 1.38 2.902 2½” 2.26 4.75

SJSlip Joint Adapter

A

Size: A 150# ANSI Pattern Holes

1½ 5” 42 6” 43 7” 44 9” 86 11” 8

BACK UPBackup Ring

A

.55 +/-.10

1

WEIGHT WEIGHTSize: A B 150# ANSI Pattern Holes PP PVDF

1½ 2¼” 5” 4 6.16 12.942 2⅝” 6” 4 8.48 17.813 3¼” 7” 4 18.18 38.184 3¼” 9” 8 26.63 55.926 5⅛” 11” 8 46.86 98.41

FLGFlange

A

B

WEIGHTSize: A B C PP

w/o BOTTLE 3⅛” 2⅛” 8.151PT 8⅝” 10.601QT 10¼” 11.732QT 11⅝” 14.00

BT1Bottle Trap w/o Bottle

A

B

C

11/2 IPS

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1½ 13⅜” 7.00 14.702 13⅝” 9.14 19.19

SJA12Slip Joint Adapter X 12

A12

Mechanical Joint

M

Dimensions are in inches. Dimensional tolerance = ±⅛”

www.orionfittings.com Acid Waste 14

Page 30: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Fitting Dimensions No-Hub/Plain EndAvailable in Polypropylene or PVDF

*Weights are approximate and in ounces.

WEIGHT WEIGHTSize: A B C D PP PVDF

1½” 9¼” 3½” 5” 3⅝” 25.20 52.922 10” 3⅜” 5¾” 3⅛” 27.95 58.70

DT1Drum Trap

A

B

C D

WEIGHT WEIGHTSize: A B PP PVDF

1½” 3” 7¼”

BT2Adjustable Riser Bottle Trapwith female threads

WEIGHT WEIGHTSize: A B PP PVDF

1½” 3” 7¼”

BT3adustable Riser Bottle TrapWithout bottle for use withglass mason Jar

Dimensions are in inches. Dimensional tolerance = ±⅛”

15 ORION Kansas City, Kansas 66117 FAX 1 800-777-1653

Page 31: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHTSize: A B C F PP

8 21/21/2 51/2

10 21/21/2 51/2

12 21/21/2 51/2

CLSCOUPLING

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 81/16

10 81/2

12 87/8

45E1/8 BEND

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 133/4

10 1413/16

12 1513/16

90E1/4 BEND

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 24 12 1210 24 12 1212 24 12 12

90T90 TEE

WEIGHT WEIGHTSize: A B C D EF PP PVDF

8x6 24 12 128x6 24 12 1210x6 24 12 1210x8 24 12 1212x8 24 12 1212x10 24 12 12

R90TREDUCING 90 TEE

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 273/16 713/16 175/8

10 307/16 81/4 2012 337/16 85/8 223/16

45YSINGLE WYE

Acid Waste Piping Systems Orion Fittings 16

Large Diameter Acid Waste Fitting DimensionsAvailable in Polypropylene

273/16

307/16

337/16

Page 32: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8x6 73/16 713/16 197/16

8x6 73/16 713/16 197/16

10x6 307/16 81/4 221/4

10x8 307/16 81/4 221/4

12x8 337/16 85/8 2413/16

12x10 337/16 85/8 2413/16

R45YReducing Single Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 273/16 713/16 201/2 201/4

10 307/16 81/4 225/8 223/8

12 337/16 85/8 249/16 245/16

LTYLong Turn Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8x6 73/16 713/16 1815/16 2311/16

8x6 73/16 713/16 201/2 249/16

10x6 307/16 81/4 2213/16 273/8

10x8 307/16 81/4 277/8 281/16

12x8 337/16 85/8 2911/16 301/4

12x10 337/16 85/8 307/16 307/16

RLTYReducing Long Turn Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 273/16 713/16 175/8

10 307/16 81/4 2012 337/16 85/8 223/16

D45YDouble Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8x6 73/16 713/16 1815/16 2311/16

8x6 73/16 713/16 201/2 249/16

10x6 307/16 81/4 2213/16 273/8

10x8 307/16 81/4 277/8 28 1/16

12x8 337/16 85/8 2911/16 301/4

12x10 337/16 85/8 307/16 307/16

RD45YReducing Double Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 273/16 713/16 201/2 2010 307/16 81/4 225/8 223/8

12 337/16 85/8 249/16 245/16

DLTYDouble Long Turn Wye

17 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Fitting Dimensions Large DiameterAvailable in Polypropylene

Page 33: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8 371/4 191/2 233/4

10 401/2 215/8 2712 49 22 28

PTRAPP Trap

Acid Waste Piping Systems Orion Fittings 18

Large Diameter Acid Waste Fitting DimensionsAvailable in Polypropylene

WEIGHT WEIGHTSize: A B C D E F PP PVDF

8x6 73/16 713/16 1815/16 2311/16

8x6 73/16 713/16 201/2 249/16

10x6 307/16 81/4 2213/16 273/8

10x8 307/16 81/4 27 7/8 28 1/16

12x8 337/16 85/8 2911/16 301/4

12x10 337/16 85/8 307/16 307/16

RDLTYReducing DoubleLong Turn Wye

Page 34: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 2.08 .88 1.28 2.692 2.08 .90 2.18 4.583 2.96 1.13 5.30 11.134 3.36 1.50 8.78 18.446 4.20 2.38 16.88 35.45

CLSCoupling

A

B

B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 1.62 1.78 3.742 .90 1.75 3.18 6.683 1.13 2.59 9.30 19.534 1.50 3.03 13.93 29.256 2.00 3.70 35.05 73.61

45E1/8 Bend

A

AB

B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 1.62 1.48 2.23 4.682 .90 1.75 1.57 4.30 9.033 1.13 2.59 2.59 3.75 7.874 1.50 3.03 3.03 21.43 45.006 2.00 3.70 4.00 66.30 139.20

SS45ESingle Socket 1/8 Bend

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 2.54 2.23 4.682 .90 3.41 4.30 9.033 1.13 4.65 3.75 7.874 1.50 5.60 21.43 45.006 2.00 7.47 66.30 139.20

90E1/4 Bend

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 2.46 2.41 2.08 4.372 .90 3.41 3.41 3.96 8.323 1.13 4.60 4.50 12.73 26.734 1.50 5.60 5.60 19.53 41.016 2.00 7.47 7.85 67.45 141.60

SS90ESingle Socket 1/4 Bend

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .95 3.25 3.63 7.622 .95 3.40 6.38 13.403 1.20 5.12 15.80 33.184 1.45 6.05 31.03 65.16

LS90ELong Sweep 1/4 Bend

34 ORION FITTINGS, INC. Acid Waste Piping Systems

Socket Fusion Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces

Page 35: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 2.34 2.52 4.60 5.20 10.922 .90 2.89 3.10 5.48 9.13 19.173 1.13 4.29 4.36 7.86 14.53 30.514 1.50 5.24 5.44 9.75 24.23 50.88

90TSanitary Tee

A A

A

B

C

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .90 .70 4.88 2.40 2.55 5.00 10.503x11⁄2 1.13 .80 6.68 3.13 3.50 12.13 25.473x2 1.13 .90 6.68 3.40 3.50 12.75 26.784x11⁄2 1.50 .74 9.75 7.13 5.44 36.03 75.664x2 1.50 .88 9.75 7.12 5.44 36.35 76.344x3 1.50 1.13 9.75 6.84 5.44 36.33 76.29

R90TReducing Sanitary Tee

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .77 7.29 2.12 3.54 4.03 8.462 .90 5.47 2.12 3.54 6.70 14.073 1.13 7.44 2.91 4.91 19.88 41.754 1.47 8.80 3.46 6.06 30.98 65.066 2.00 14.63 9.54 13.39 86.23 181.10Countersink clean-out plug included

COTClean Out Tee

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 6.30 2.00 4.34 5.84 12.262 .90 7.23 2.28 4.96 9.71 20.393 1.13 8.25 2.20 6.00 28.10 59.014 1.50 11.20 3.30 7.80 44.50 93.456 1.84 14.68 3.98 13.70 104.40 219.20

45YSingle Wye

A

A

AB

CD

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .90 .88 7.26 2.28 5.00 5.90 12.393x11⁄2 1.13 .70 6.25 1.25 5.40 11.55 24.263x2 1.13 .90 7.26 2.16 6.18 16.55 34.764x11⁄2 1.50 .88 8.20 2.00 7.71 16.10 33.814x2 1.50 .90 8.20 2.00 6.54 14.80 31.084x3 1.50 1.13 9.97 2.86 7.12 26.30 55.236x2 2.00 .90 14.68 4.00 12.23 62.23 130.706x3 2.00 1.13 14.68 4.00 11.00 57.85 121.506x4 2.00 1.50 14.68 4.00 11.00 58.90 123.70

R45YReducing Single Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 6.30 5.11 5.49 4.68 9.832 .90 7.23 5.73 6.26 8.35 17.543 1.13 8.25 7.87 7.48 25.05 52.614 1.50 11.20 9.63 9.90 39.03 81.966 1.84 14.68 14.91 15.19 120.26 252.50

LTYLong Turn Wye

A

A

A

B

C

D

Acid Waste Piping Systems ORION FITTINGS, INC. 35

Acid Waste Fitting Dimensions Socket FusionAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces

Page 36: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .90 .88 7.26 7.22 7.88 7.65 16.073x11⁄2 1.13 .88 6.25 5.99 5.62 14.91 31.313x2 1.13 .90 7.26 6.59 7.00 19.56 41.084x11⁄2 1.50 .88 8.20 7.50 7.88 21.67 45.514x2 1.50 .90 8.20 6.85 7.10 21.35 44.844x3 1.50 1.13 9.97 8.66 8.93 33.90 71.196x2 2.00 .90 14.68 10.87 13.12 94.63 198.706x3 2.00 1.13 14.68 11.40 12.81 67.70 142.206x4 2.00 1.50 14.68 11.89 12.86 71.23 149.60

RLTYReducing Long Turn Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .65 3.18 4.33 1.13 4.68 9.832 .90 4.16 5.80 1.63 8.35 17.543 1.13 6.00 8.25 2.20 25.05 52.614 1.50 7.80 11.20 3.30 39.03 81.966 1.84 13.70 14.68 3.98 120.26 252.50

D45YDouble Wye

A

A A

A

BBC

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .88 .76 8.69 2.47 5.40 10.95 23.003x11⁄2 1.13 .76 6.25 1.25 5.40 13.10 27.513x2 1.13 .90 8.20 2.00 6.20 19.18 40.284x11⁄2 1.50 .88 8.20 2.00 7.59 23.30 48.934x2 1.50 .90 8.20 2.00 6.54 21.83 45.844x3 1.50 1.13 9.85 2.50 7.30 32.43 68.106x2 2.00 .90 14.68 4.00 12.23 72.26 151.706x3 2.00 1.13 14.68 4.00 11.00 65.60 137.806x4 2.00 1.50 14.68 4.00 11.00 63.50 133.40

RD45YReducing Single Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 4.33 4.46 3.97 8.05 16.912 .90 5.80 5.25 6.12 14.37 30.183 1.13 8.25 7.87 7.48 41.35 86.844 1.50 11.20 9.63 9.90 65.79 138.206 1.84 14.68 14.91 15.19 156.60 328.90

DLTYDouble Long Turn Wye

A A

A

A

B

C C

D D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .90 .88 7.26 7.22 7.88 14.57 30.603x11⁄2 1.13 .88 6.25 5.99 5.62 16.72 35.113x2 1.13 .90 7.26 6.59 7.00 25.20 52.924x11⁄2 1.50 .88 8.20 7.50 7.88 26.40 55.444x2 1.50 .90 8.20 6.85 7.10 49.70 104.404x3 1.50 1.13 9.97 8.66 8.93 28.05 58.916x2 2.00 .90 14.68 10.87 13.12 137.06 287.806x3 2.00 1.13 14.68 11.40 12.81 83.20 174.706x4 2.00 1.50 14.68 11.89 12.86 90.26 189.50

RDLTYReducing Double Long Turn Wye

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .80 .88 2.08 1.08 2.272 .80 .90 2.08 1.88 3.953 1.50 1.13 3.02 4.30 9.034 1.60 1.50 3.33 6.75 14.186 2.00 2.00 4.22 18.00 37.80

MAMale Adapter

AB

C

36 ORION FITTINGS, INC. Acid Waste Piping Systems

Socket Fusion Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

*Weights are approximate, in ounces

Page 37: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .80 .88 2.08 1.30 2.732 .80 .90 2.08 2.25 4.733 1.40 1.13 2.96 5.53 11.614 1.50 1.50 3.36 9.05 19.016 1.99 2.00 4.22 8.35 17.54

FAFemale Adapter

AB

C

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .80 .88 2.08 1.75 3.682 .80 .90 2.08 3.28 6.893 1.40 1.13 2.96 7.35 15.444 1.50 1.50 3.36 13.10 27.516 1.99 2.00 4.22 26.28 55.19

COAClean Out Adapter

ABC

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .37 .99 .50 1.202 .67 .99 1.02 2.143 .67 1.11 1.83 3.844 .67 1.11 4.10 8.616 .98 1.35 7.93 16.65

CPCClean Out Plug

B A

ORIONKCKUSA

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 1.30 1.08 2.272 .90 1.30 1.48 3.113 1.13 1.52 2.70 5.674 1.23 1.55 6.45 13.556 2.38 2.82 20.63 43.32

CAPCap

A B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .88 1.90 1.30 2.733x11⁄2 .75 2.72 3.13 6.573x2 .88 2.57 3.33 6.994x11⁄2 .75 3.32 5.00 10.504x2 .90 3.27 5.18 10.884x3 1.13 3.07 5.45 11.456x2 .88 4.97 17.68 37.136x3 1.13 3.76 14.23 29.886x4 1.40 3.76 14.35 30.14

RBReducing Bushing

AB

Female End

Acid Waste Piping Systems ORION FITTINGS, INC. 37

Acid Waste Fitting Dimensions Socket FusionAvailable in Polypropylene or PVDF

WEIGHT WEIGHTSize: A B C D E F PP PVDF

2x11⁄2 .88 .90 2.083x11⁄2 .76 1.13 3.003x2 .90 1.13 3.204x11⁄2 .88 1.50 4.824x2 .90 1.50 3.604x3 1.13 1.50 3.446x2 .88 2.00 4.826x3 1.13 2.00 3.606x4 1.40 2.00 3.60

RCLSReducing Coupling

*Weights are approximate, in ounces

Page 38: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 8.90 4.77 4.00 3.27 .88 11.89 24.972 10.48 5.67 5.00 3.57 .90 19.20 40.32

UTRRunning Trap

A

B

C

D

E E

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 8.22 4.85 2.99 .88 12.78 26.842 10.11 5.55 3.19 .90 21.15 44.42

UTPSS Trap

A

BC

D

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 2.54 4.38 6.92 6.91 14.512 .90 3.41 5.92 9.33 11.70 24.573 1.13 4.60 7.76 12.36 38.63 81.124 1.50 5.60 9.64 15.24 60.25 126.506 2.00 7.47 13.32 20.79 197.05 413.80

RBPP Trap

AA

BC

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .88 2.54 1.92 8.51 8.99 18.882 .90 3.41 2.51 11.84 16.29 34.213 1.13 4.60 3.16 15.47 55.02 115.504 1.50 5.60 4.04 19.28 80.97 170.00

RBPSS Trap

A AB C

D

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .51 .80 2.02 1.63 3.422 .71 .90 2.77 2.95 6.20

RLNSSink Tail Piece Adapter

38 ORION FITTINGS, INC. Acid Waste Piping Systems

Socket Fusion Acid Waste Fitting DimensionsAvailable in Polypropylene or PVDF

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 6.45 4.77 4.00 4.85 3.27 .88 6.80 13.402 7.74 5.67 5.00 5.55 3.57 .90 11.60 25.30

UTPFull Drop Union P-trap 15 EPS

*Weights are approximate, in ounces

Page 39: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 2.22 .88 1.55 3.262 2.44 .90 2.76 5.80

SJSlip Joint Adapter

A

B

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 13.34 7.16 15.042 13.54 90.24

SJA12Slip Joint Adapter X 12

A

SOCKET FUSION

12

WEIGHTWEIGHTSize: A B C 150# ANSI Holes PP PVDF

11⁄2 1.15 .88 5.00 4 5.18 10.882 1.22 .90 6.00 4 6.80 14.283 1.62 1.13 7.50 4 14.08 29.574 1.65 1.50 9.00 8 20.55 43.166 2.70 2.38 11.00 8 31.58 66.32

FLGFlange

A

B

C

WEIGHT WEIGHTSize: A B 150# ANSI Holes PP PVDF

11⁄2 5.00 42 6.00 43 7.50 44 9.00 86 11.00 8

BACK UPBackup Ring

A

.55 +/-.10

150# ANSI B lt P tt

WEIGHT WEIGHTSize: A B C D PP PVDF

W/O BOTTLE .67 2.11 2.10 7.17 15.061PT 8.621QT 10.262QT 11.65

BT1Bottle Trap w/ Bottle

WEIGHT WEIGHTSize: A B C D E F PP PVDF

1-1/2 9.25 3.71 4.66 2.57 .84 23.80 49.982 9.90 3.33 5.76 3.25 .85 28.28 59.39

DT1Drum Trap

Acid Waste Piping Systems ORION FITTINGS, INC. 39

Acid Waste Fitting Dimensions Socket FusionAvailable in Polypropylene or PVDF

WEIGHT WEIGHTSize: A B C D E F PP PVDF

11⁄2 .51 13.25 7.33 15.392 .71 13.87 9.86 20.71

RLNS12Sink Tail Piece Extension

*Weights are approximate, in ounces

Page 40: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Floor Drain AWFDSTD

Accessories Available• Sediment Bucket• Flashing Clamp• ½” Trap Primer• Solid Cover• Funnel• Vandal Proofing

Recommended Specification: ORIONAWFDSTD Corrosion Resistant Floor Drainmanufactured from fire retardant polypropy-lene material conforming to ASTM D4101.Grate, plug, and covers are to be made fromfiber-filled polypropylene for strength and dura-bility.

Recommended Specification: ORIONAWFDSTD Corrosion Resistant Floor Drainmanufactured from PVDF material conformingto ASTM D3222. Grate, plug, and covers areto be made from fiber-filled PVDF for strengthand durability.

Note:Funnel replaces plug in AWFDSTD grate.

19 ORION FITTINGS, INC. Acid Waste Piping Systems

WEIGHT WEIGHTSize: A B C D E PP PVDF

2 4.54 45.57 95.1783 4.60 42.43 89.044 4.87 50.18 105.776 3.65 85.28 179.99

AWFDSTDNo-Hub/Plain End

AWFDSTDTop View

WEIGHT WEIGHTSize: A B C D E PP PVDF

2 4.16 .88 46.50 94.663 2.94 1.13 43.30 90.774 2.94 1.36 44.10 91.846 3.50 1.98 80.26 165.442 FIP 5.12 .80 47.20 95.603 FIP 3.00 1.40 45.80 91.844 FIP 2.94 1.50 50.98 108.716 FIP 3.50 1.99 90.84 186.34

AWFDSTDSocket Fusion

Floor Drain DimensionsComplete with Grate and Plug

Page 41: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Floor Drain AWFDSO

Accessories Available• Sediment Bucket• Flashing Clamp• 1½" Trap Primer• Solid Cover• Funnel• Vandal Proofing

Recommended Specification: ORIONAWFDSO Corrosion Resistant Floor Drainmanufactured from Fire RetardantPolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to bemade from fiber-filled polypropylene forstrength and durability.

Recommended Specification: ORIONAWFDSO Corrosion Resistant Floor Drainmanufactured from PVDF material conformingto ASTM D3222. Grate, plug, and covers areto be made from fiber-filled PVDF for strengthand durability.

Acid Waste Piping Systems Orion Fittings 20

WEIGHT WEIGHTSize: A B C D E PP PVDF

2 6.69 3.41 50.23 105.293 7.84 4.56 60.13 121.994 6.97 5.60 62.58 125.12

AWFDSONo-Hub/Plain End

AWFDSOTop View

Dimensions Floor Drain(Side Outlet) Complete with Grate and Plug

Page 42: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Floor Drain AWFDPTFloor Drain with Trap complete with grate

and plug

Accessories Available• Sediment Bucket• Flashing Clamp• 1½" Trap Primer• Solid Cover• Funnel• Vandal Proofing

Recommended Specification: ORIONAWFDPT (integral trap) Corrosion ResistantFloor Drain manufactured from Fire RetardantPolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to bemade from fiber-filled polypropylene forstrength and durability.

Recommended Specification: ORIONAWFDPT (integral trap) Corrosion ResistantFloor Drain manufactured from PVDF materialconforming to ASTM D3222. Grate, plug, andcovers are to be made from fiber-filled PVDFfor strength and durability.

21 ORION FITTINGS, INC. Acid Waste Piping Systems

WEIGHT WEIGHTSize: A B C D E PP PVDF

2 5.87 9.33 5.92 58.26 118.223 6.57 12.31 7.71 85.59 175.324 6.04 15.24 9.64 102.69 205.77

AWFDPTNo-Hub/Plain End

AWFDPTTop View

Floor Drain & Trap DimensionsComplete with Grate and Plug

Page 43: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Corrosion Resistant Finished FloorCleanoutIn applications where a cleanout is required

in a finished floor, Orion offers either a nickelbronze or brushed bronze cover. The lettersAWCO (Acid Waste Cleanout) are cast in thecover to help prevent confusion with a sanitarysewer cleanout if maintenance is required.

Both styles of covers are supplied with a fer-rule with a countersunk plug and adjustable topto facilitate easy installation when the floor ispoured.

Recommended Specification: ORION FCOcorrosion resistant finished floor cleanout.Manufactured from fire retardant polypropylenematerial conforming to ASTM D 4101, ferrulesupplied with countersunk plug and adjustabletop with round (square) nickel bronze (brushedbronze) cover, with AWCO (Acid WasteCleanout) cast in cover.

Recommended Specification: ORION FCOcorrosion resistant finished floor cleanout.Manufactured from PVDF material conformingto ASTM D 3222, ferrule supplied with counter-sunk plug and adjustable top with round(square) nickel bronze (brushed bronze)cover, with AWCO (Acid Waste Cleanout) castin cover.

Acid Waste Piping Systems Orion Fittings 22

Model & Size Finish Available

3" FCO SquareNickel Bronze; Brushed Bronze4" FCO SquareNickel Bronze; Brushed Bronze

FCO-SQTop View

Model & Size Finish Available

3" FCO RoundNickel Bronze, Brushed Bronze PP PVDF4" FCO RoundNickel Bronze; Brushed Bronze PP PVDF

FCO-RDTop View

FCOSide View

Dimensions Floor CleanoutComplete with Grate and Plug

5⁄16"x18 AdjustingScrews

Page 44: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

FLAME RETARDANT POLYPROPYLENE

Property Unit Value Test Method

Nominal Melt Flow g/10 min 0.75 ASTM D1238(at 230° C / 2.16 kg)

Density g/cm3 0.901 ASTM D792(at 73° F)Tensile Strength psi 3400 ASTM D638(at Yield)Elongation at Yield % 15 ASTM D638Modulus of Elasticity psi 150,000 ASTM D790AIzod Impact, notched ft-lb/in 13 ASTM D256

(at 73° F – 1/8” bar)Rockwell Hardness R scale 77 ASTM D785Melting Point ° F 324 Aristech

° C 162 AristechSpecific Gravity — .905 ASTM D792Water absorption % .02 ASTM D570

(24hrs @73° )FFlammability

Rate of Burning cm/min 1.25 ASTM D635Smoke Density Rating % 48 ASTM D2843Burning Class — V-2 UL 94Limiting Oxygen Index % 17 ASTM D2863

Polypropylene Material Cell Class PP0348 ASTM D4101Corrosive Waste Drainage System Complies ASTM F1412

NON-FLAME RETARDANT POLYPROPYLENE

Property Unit Value Test MethodNominal Melt Flow g/10 min 0.75 ASTM D1238(at 230° C / 2.16 kg)

Density (at 73° F) g/cm3 0.901 ASTM D792Tensile Strength at Yield psi 3400 ASTM D638Elongation at Yield % 15 ASTM D638Modulus of Elasticity psi 150,000 ASTM D790AIzod Impact, notched ft-lb/in 13 ASTM D256at 73° F – 1/8” barRockwell Hardness R scale 77 ASTM D785Melting Point ° F 324 Aristech

° C 162 AristechSpecific Gravity .905 ASTM D792Water absorption % .02 ASTM D57024hrs @73° F

Polypropylene Material Cell Class PP 0348 ASTM D4101Corrosive Waste Drainage System Complies ASTM F1412

Acid WAcid Waste Piping aste Piping Physical Propert iesPhysical Propert ies

44 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 45: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

PVDF

Property Unit Value Test Method

Specific Gravity 1.76 ASTM D-792Water Absorption % .03 ASTM D-570

24 Hrs.@ 73ºFTensile Strength psi psi 6,000 ASTM D-638

@ 73º FModulus of Elasticity psi 210,000 ASTM D-638

@73ºFFlexural Modulus psi psi 9,700 ASTM D-790Izod Impact Strength Ft-Lb/In 3.8 ASTM D-256

@ 73ºF (Notched)Hardness Shore D 78 ASTM D-2240Melting Point ºF 330 ASTM D-3418Coefficient of Thermal In/InºF x 10-5 7.4 ASTM D-696

Expansion Thermal Conductivity BTU-in/HR/Sq.Ft./ºF 1.18 ASTM D-433Heat Distortion Temp. psi 251 ASTM D-648

@ 66psiHeat Distortion Temp. psi 221 ASTM D-648

@ 264psiResistance to Heat ºF 230at Continuous DrainageLimiting Oxygen % 44 ASTM D-2836

Index (%)

Flame Spread 0-5 ASTM E-84Smoke Developed 35 ASTM E84Underwriters Lab V-0 UL. 94

Rating (sub. 94)PVDF Material Class Type I, Grade II ASTM D3222Corrosive Drainage Waste System Complies ASTM F1673

Physical Propert iesPhysical Propert ies ACID WASTE PIPING

Acid Waste Piping Systems ORION FITTINGS, INC. 45

Page 46: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Installing Drainage SystemsProper installation of Orion drainage sys-

tems is extremely important in assuring thatinstallations perform flawlessly for years.

Supporting a Drainage SystemSince Polypropylene has a higher expan-

sion rate than that of other materials, it cannotbe anchored to restrict movement from ther-mal expansion incurred from chemical reac-tions or the inadvertent dumping of hot waterinto the acid waste system.

Orion recommends the use of clevis orloop type pipe hangers. If split-ring or otherhanger types are used the hanger should bea size larger than the pipe being supportedso the polypropylene pipe is free to move.(For example, if supporting 2" pipe, use 3"hangers, or when supporting 3" pipe, use4"hangers, etc.)

Warnings:• The use of uni-strut type hangers or any

hanger which relies on clamp tightness forsupport voids manufacturers warranty.

• Do not clamp a polypropylene pipe sys-tem tightly. It must be free to move.

Recommended Hanger Spacing forOrion Polypropylene DrainageSystems Schedule 40 & Schedule 80*

Pipe size, inches Hanger Spacing, feet

11⁄2 42 43 54 66 68 6

10 712 7

*Or per code.

Recommended Hanger Spacing forOrion PVDF Drainage Systems*

Pipe, size, inches Hanger spacing, feet

11⁄2 4.52 53 5.54 66 7

*Or per code.

Pipe SpecificationsPolypropylene Acid Waste Pipe manufac-

tured from resin meeting ASTM D4101. Pipemeets the dimensional tolerances of ASTMD2447. All pipe is supplied in 10' sections (20'optional). All pipe is pregrooved at the factory.

PVDF Pipe manufactured from resin meet-ing ASTM D3222. Pipe meets the dimensionaltolerances of ASTM D2447. All pipe is sup-plied in 10' sections (20' optional). All pipe ispregrooved at the factory. All PVDF pipe ismarked with UL 723 classified.

Fitting Specifications

No-Hub/Plain End Fittings— Orion No-Hub/Plain End fittings meet or exceed ASTMF1412. Polypropylene fittings are manufac-tured from polyolefin material in accordancewith ASTM D4101. PVDF fittings are manu-factured from Kynar® brand of PVDF resinmeeting ASTM D3222. The outer band ofeach No-Hub/Plain End is 300 series stainlesssteel, and 5⁄16" bolts, nuts and washers platedto meet a 100 hour salt spray test per ASTMB117.

Socket Fusion Fittings— Socket fusion sys-tems conform to ASTM F1412. Orion socketfusion fittings meet or exceed ASTM D2657standards. Polypropylene fittings are manufac-tured from polyolefin material in accordancewith ASTM D4101. PVDF fittings are manufac-tured from Kynar® brand of PVDF resin meetingASTM D3222.

Rionfuse Electrofusion Fittings— OrionRionfuse fittings meet or exceed ASTM F1412.Polypropylene fittings are manufactured from poly-olefin material in accordance with ASTM D4101.

The molded coil is made of heavy gauge wire.Clamps are not to be used at any time duringinstallation.

Underground Installation of Orion Acid Waste SystemsThe trench as excavated for the pipe installation

must be free of loose stones, building materials oroutcroppings, and must provide minimum clear-ance around pipe of half the pipe diameter oneach side (horizontally) and one pipe diameterabove and below (vertically). The trench shall bebackfilled over the unexcavated base to a depth ofone pipe diameter with clean backfill. The backfillmaterial shall be free of stones and foreign matterand shall be capable of passing a No. 10 screen.

46 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid WAcid Waste Piping aste Piping Design DataDesign Data

Page 47: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

The piping shall be installed over this mate-rial and tested in accordance with applicableplumbing codes.

After testing, initial backfilling must be care-fully accomplished, still using No. 10 screenmaterial until fill surrounds the pipe. When theselected backfill meets a depth of one diameterover the pipe, then backfilling can proceed withnormal fill until complete. Fill shall be compact-ed using hand held compacting equipmentwhen fill is midway up the pipe, and again whenthe fill is over one diameter over the pipe.Heavy-duty compacting equipment can beused after the initial backfill is completed.

Testing Procedures

Fully inspect the installed piping for evidenceof mechanical abuse and suspect joints.

Split the system into convenient test sections,not exceeding 1000 ft. The piping should becapped off with an expandable plug at the endof the pipesection to be tested.

We suggest that straight lengths of pipe

should be backfilled between the fittings being test-ed, prior to testing.

Slowly fill the pipe section with water, taking care toremove all trapped air in the piping. Use airrelease valves in any high spots in the system. Donot pressurize at this stage.

Leave the pipe for at least one hour, to allow anequilibrium temperature to be achieved.

Visually check the system for leaks. If clear, checkfor and remove any remaining air from the system.

Pressurize the system to a suggested maximum of10 feet head by means of a standard 10 footstanding water test using a 10-foot vertical riser, ora low pressure hand pump.

Leave the line at 10 feet of head pressure for aperiod of up to 8 hours, during which time thewater level should not change, (standing watertest) or the pressure gauge reading should notchange (hand pump test).

Acid Waste Piping Systems ORION FITTINGS, INC. 47

Mechanical CouplingsPart Material Type Standard Size," Galvanic Reaction

Outer band Stainless steel AISI 304-2B ASTM A240 — —

Bolt bar Stainless steel AISI 304-2B ASTM A240 — —

Bolt* Carbon steel Cadmium plated with Grade 8 5/16-18x1 ⁄ —

dichromate coating

Nut* Carbon steel Cadmium plated with — 5/16-18 —

dichromate coating

Washers* Carbon steel Cadmium plated with

dichromate coating — 5/16 —

Welding Stainless steel Automatic MIG — — Basically nil

with Tri-Mix

Coupling body: Made from thermoplastic resin. This material has similar chemical resistant properties as the pipe and fittings

manufactured by Orion. It has been selected because of its excellent ability to be used as a gasket.

ASTM

Density .914 D792Tensile 2100 D1238

Low temp. brittleness (-76(F) D746

Vical softness point 185(F (85(C) D1525

Flexural stiffness 12,700 psi D747

Torsional stiffness 14,900 psi D1043

*Bolt, nut, washer are plated to meet 100 hour salt spray test per ASTM D117.

Design DataDesign Data ACID WASTE PIPING

Page 48: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

If there is a significant drop in pressure, or extended timesare required to achieve the desired pressure, either jointleakage has occurred or air is still trapped in the line. Inthis event, inspect for joint leaks. If none are found,check for trapped air - this air must be removed prior tocontinuing the test.

If joints are found to be leaking, the system must be fullydrained and the joints repaired. Dry or marginal Rionfusejoints can be easily re-fused by following the proceduresdetailed in this catalog. Leaking joints can be backweldedif necessary. It should not be necessary to cut out joints,unless the joint haspreviously been overheated, contaminated, fractured orvery badly made in the first place. Where joints have tobe cut out and replaced, the procedures for field cuts andjoint installation detailed in this manual should be fol-lowed.

Repeat the 10 feet head test after repairing any leaking joints, following the procedure described above.

NOTE: Tanks should not be pressure tested.

Pressure:This system was designed for acid waste of a gravity

nature. Some low-pressure applications are possible, butshould be checked with factory engineering departmentbefore specification or installation. Do not use compressedair or other compressed gases for testing or use.

The manufacturer DOES NOT RECOMMEND No-Hub/Plain End couplings for use in systems used fordumping hot water appliances (autoclaves, dishwashers,sterilizers, etc). For these systems, Orion socket fusion isrecommended on main stacks carrying hot water and allruns within 75 feet of appliance.

Thermal Expansion TablePolypropylene

∆T ∆T ∆T ∆T ∆T∆T ∆T Length 40ºF 50ºF 60ºF 70ºF 80ºF 90ºF 100ºF20 ft .57 .70 .85 .99 1.13 1.27 1.4240 ft 1.13 1.42 1.67 1.98 2.27 2.55 2.8360 ft 1.70 2.12 2.55 2.97 3.40 3.82 4.2580 ft 2.27 2.83 3.40 3.97 4.53 5.10 5.66100 ft 2.83 3.54 4.25 4.96 5.66 6.37 7.08

PVDF∆T ∆T ∆T ∆T ∆T

∆T ∆T Length40ºF 50ºF 60ºF 70ºF 80ºF 90ºF 100ºF20 .72 .90 1.08 1.26 1.44 1.62 1.8040 1.44 1.80 2.16 2.52 2.88 3.24 3.6060 2.16 2.70 3.24 3.78 4.32 4.86 5.4080 2.88 3.60 4.32 5.04 5.76 6.48 7.20100 3.60 4.50 5.40 6.30 7.20 8.10 9.00

To calculate thermal expansion, use theformula: ∆L=12eL∆T

e= coefficient of thermal expansion

e = 5.9 x 10-5 in/in ºF (.000059") for Polypropylenee = 7.5 x 10-5 in/in ºF (.000075") for PVDF

Polypropylene Example:Highest temperature expected: 100ºFLowest temperature expected: 50ºFTotal variation: ∆T: 50ºFLength of run: 20 ft.Change in T: 50ºFChange in L: .708"Where:Change in L= change in length from

thermal expansion or contraction (inches)∆T = difference between highest and lowesttemperature expected (0ºF)e = coefficient of thermal expansionL= length of pipe run (feet)

Example:L= 20ft∆T = 50(F∆L= 12 x .000059 x 50 x 20∆L= .708"

Pipe Dimension Data—ASTM F1412Nom Size Average O.D. Schedule 40 Schedule 80inches wall thickness wall thickness1-1/2 1.900 .145 .2002 2.375 .154 .2183 3.500 .216 .3004 4.500 .237 .3376 6.625 .280 .4328 8.625 .322 .50010 10.750 .365 .59312 12.750 .406 .687

All Orion Drainage Pipe Dimensions MeetsASTM F1412 Specifications

PitchOrion drainage systems are designed to allow for

1/4” pitch per foot. Installation should be planned toallow for full usage of this pitch.

48 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Piping Design Data

Page 49: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Recommended Pipe SupportSchedule For Above GroundInstallations.

• Data based on Orion pipe supported onuniform centers, carrying liquids havingspecific gravities up to 1.30, without majorload concentration.

• These recommendations are foruninsulated lines. If pipe is insulated thespans should be reduced by 35% toaccommodate the weight of insulation.

• Never support pipe in tight clamps; linesmust be free to move axially.

• Do not use compressed air or othercompressed gases for testing of or use inany Orion system. Use of compressed airor gases voids any and allwarranties.Schedule 40

Polypropylene* High Purity Pipe (maximum span, feet).

Schedule 40Temperature, ºF

Pipe Size 70 120 150

1⁄2" 4 3 continuous3⁄4" 4 3 continuous

1" 4.5 3 continuous

11⁄2" 5 3.5 continuous

2" 5 3.5 2

3" 6 3.5 2.5

4" 6 4.5 3

Schedule 80Temperature, ºF

Pipe Size 70 120 150

1⁄2" 5 3.5 continuous3⁄4" 5 3.5 continuous

1" 5.5 4 continuous

11⁄2" 5.5 4 2.5

2" 6 4.5 2.5

3" 7 5 3

4" 7.5 5 3.5

*Whiteline or Standardline

PVDF High Purity Pipe (maximum span, feet).

Schedule 40Temperature, ºF

Pipe Size 70 120 150

1⁄2" 4 3 continuous3⁄4" 4.5 3 continuous

1" 4.5 3.5 continuous

11⁄2" 5.5 4 continuous

2" 5.75 4 2

3" 6.5 4.5 2.5

4" 7.5 5 3

Schedule 80Temperature, ºF

Pipe Size 70 120 150

1⁄2" 5 3.5 continuous3⁄4" 5.5 3.5 continuous

1" 5.5 4 continuous

11⁄2" 6 4 2.5

2" 6.5 4.5 2.5

3" 7 5 3

4" 8 5 3.5

Acid Waste Piping Systems ORION FITTINGS, INC. 49

Design Data ACID WASTE PIPING

Page 50: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

50 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Piping Design Data

Maximum Service TemperaturesAs with all plastics, Polypropylene and PDVF have minimum and maximum service temperatures.

Exposure to certain chemicals may effect the maximum service temperatures of plastics and thereforeour chemical compatibility charts should be considered when determining the maximum working temper-atures of our piping systems. The joining method will also effect the maximum temperature of any plas-tic piping system.

The below information can be used as a guide for determining the maximum service temperatures forpolypropylene and PVDF based on water as the medium.

Polypropylene

Socket Fusion

•200ºF - Constant or Intermittent Flow

Rionfuse

•180ºF - Constant Flow

•200ºF - Intermittent Flow

No-Hub/Mechanical Joint•160ºF - Intermittent Flow•120ºF - Constant Flow

PVDFSocket Fusion•285ºF - Constant or Intermittent FlowNo-Hub/Mechanical Joint•180ºF - Intermittent Flow•160ºF - Constant Flow

Page 51: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acetaldehyde 100Acetamide 100Acetate Solvents, Crude NRAcetate Solvents, Pure NRAcetic Acid 5 180Acetic Acid 10 180Acetic Acid 20 180Acetic Acid 30 180Acetic Acid 50 180Acetic Acid 60 150Acetic Acid 80 150Acetic Acid, Glacial 120Acetic Anhydride 73Acetic Ether (See Ethyl Acetate) 73Acetone 120Acetonitrile (Methyl Cyanide) NRAcetophenone 73Acetyl Propane 130Acetylene 73Acid Mine Water 150Acrylic Acid NRAcrylonitrile 73Adipic Acid Aqueous 120Alcohol, Allyl 140Alcohol, Amyl 73Alcohol, Butyl 180Alcohol, Ethyl 180Alcohol, Isopropyl 120Alcohol, Methyl 180Alcohol, Polyvinyl 120Allyl Chloride 73Alum (See Aluminum Sulfate) 180Alum, Ammonium 180Alum, Chrome 180Alum, Potassium 180Aluminum, Chloride 180Aluminum, Fluoride 180Aluminum, Hydroxide 180Aluminum, Nitrate 180Aluminum, Potassium Sulfate (Potash Alum) 180Aluminum, Sulfate 10 180Ammonia 25 150

Ammonia 99 120Ammonium, Acetate 150Ammonium, Bifluoride 180Ammonium, Carbonate 180Ammonium, Chloride 150Ammonium, Fluoride 10 180Ammonium, Fluoride 20 180Ammonium, Hydroxide 180Ammonium, Nitrate 180Ammonium, Persulfate NRAmmonium, Phosphate 180

Dibasic 180Monobasic 180Tribasic 180

Ammonium, Sulfate 180Ammonium, Sulfide 180Amyl, Acetate NRAmyl Chloride NRAniline 150Aniline Hydrochloride 73Anthraquinone Sulfonic Acid 73Anti-Freeze (See Ethylene Glycol) 150Antimony Trichloride 120Aqua Regia NRArsenic Acid 140Aryl Sulfonic Acid NRBaking Soda (See Sodium Bicarbonate) -Barium Carbonate 180Barium Chloride 180Barium Hydroxide 180Barium Nitrate 180Barium Sulfate 180Barium Sulfide 180Beer 180Beet Sugar Liquors 150Benzaldehyde 10 120Benzene NRBenzene Sulfonic Acid 10 180Benzene Sulfonic Acid 100 150Benzoic Acid 150Benzol (see Benzene) NRBismuth Carbonate 180

Generally speaking, the chemical resistance of polypropylene and polyethylene is considered superior to that of met-als. They are unaffected by most inorganic acids, alkalis, and aqueous solutions which rapidly corrode metals, althoughsome concentrated acids and oxidizing agents can attack them, especially at elevated temperatures.

IMPORTANT NOTICE: This data refers to drainage systems usage only.For chemicals not listed, check with Orion.The information appearing here has been assembled from sources believed to be reliable, but is not guaranteed by Orion. Orion is not respon-

sible for its accuracy or reliabilty. In manufacturing its products, Orion uses raw materials manufactured by others, and Orion has no control over themethods used in installing its products or the conditions under which they are used. It does not make any representation concerning either the chem-ical resistance properties of its products or the toxicological effects of chemicals reacting with them. Nothing appearing here should be consideredas a recommendation for any use that would infringe patent rights or an endorsement for the use of any particular material or chemical or any classof materials or chemicals.

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Chemical Resistance of Polypropylene and Polyethylene

Acid Waste Piping Systems ORION FITTINGS, INC. 51

Page 52: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Bismuth Carbonate 180Black Liquor 150Bleach—see Sodium Hypochlorite 12.5 150Borax, Sodium Borate 180Boric Acid 180Brine 180Bromic Acid NRBromine Dry NRBromine Gas, Wet NRBromine Liquid NRBromine Water NRButane 73Butanol (see Alcohol, Butyl) NRButyl Acetate NRButyl Chloride (Chlorobutane) NRButyl Ether NRButyl Phenol NRButyl Phthalate 180Butylamine NRButylene (Liqudied Petroleum Gas) NRButyric Acid 180Calcium Acetate 180Calcium Bisulfide 180Calcium Bisulfite 180Calcium Carbonate 180Calcium Chlorate 180Calcium Chloride 150Calcium Hydroxide 180Calcium Hypochlorite 120Calcium Nitrate 180Calcium Sulfate 180Cane Sugar Liquors 180Carbon Dioxide (wet or dry) 180Carbon Disulfide NRCarbon Monoxide 180Carbon Tetrachloride NRCarbonic Acid 180Castor Oil 120Caustic Lime (Calcium Hydroxide) 180Caustic Soda (Sodium Hydroxide) 10 180Chloric Acid 20 NRChlorine Gas Wet NRChlorine Liquid NRChlorine Water Sat 180Chlorosulfonic Acid NRChromic Acid 5 120Chromic Acid 10 120Chromic Acid 20 120Chromium Alum 120Citric Acid 150Clorox Bleach 120Coconut Oil 150Coke Oven Gas 73

Chemical Resistance of Polypropylene and Polyethylene

Copper Carbonate 150Copper Chloride 150Copper Cyanide 150Copper Fluoride 150Copper Nitrate 150Copper Salts 150Copper Sulfate 150Copper Sulfate 5 150Corn Oil 100Corn Syrup 150Cottonseed Oil 180Creosote NRCresols NRCresylic Acid NRCroton Aldehyde 73Crude Oil 73Cupric Cyanide (see Copper Cyanide) 150Cupric Fluoride 150Cupric Nitrate 150Cupric Salts 150Cupric Sulfate (see Copper Sulfate) 150Cyclohexane NRCyclohexanol 73Cyclohexanone NRDecalin 180Detergents 180Detergents Heavy Duty 150Dextrin Starch Gum 150Dextrose (Glucose) 150Diacetone Alcohol 120Diazo Salts 120Dibenzyl Ether NRDibutyl Phthalate 73Dichlorethane (Ethylene Dichloride) NRDichlorobenzene 73Dichloroethylene NRDichloroisopropyl (Ether) NRDichloromethane NRDiesel Fuel 73Diethyl Cellosolve 73Diethylamine 120Diethylbenzene NRDiethylether (Ether) 73Dimethyl Ketone (see Acetone) 120Dimethyl Phthalate NRDimethylamine 120Dimethylbenzene NRDimethylformanide 120Dioctyl Phthalate NRDioxane 73Dipropylene Glycol 120Disodium Phosphate 180Distilled Water 180

52 ORION FITTINGS, INC. Acid Waste Piping Systems

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Page 53: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Divinylbenzene NRDry Cleaning Solvents 73Epichlorohydrin 120Epsom Salts 150Esters (General) NREthane NREthanol (see Alcohol Ethyl) 180Ethanolamine NREthers NREthyl Acetate 73Ethyl Acetate 120Ethyl Alcohol 150Ethyl Bromide NREthyl Chloride (Chiroethane) NREthyl Ether 73Ethyl Formate NREthylbenzene NREthylene Bromide NREthylene Chlorohydrin 73Ethylene Diamine 73Ethylene Dichloride (Dichloroethane) NREthylene Glycol 150Ethylene Oxide NRFatty Acids 180Ferric Chloride 180Ferric Nitrate 180Ferric Sulfate 180Ferrous Chloride 180Ferrous Nitrate 180Ferrous Sulfate 180Fish Solubles 180Fluoboric Acid 73Fluorine Gas 1 wet NRFluorine, Liquid 25 NRFluosilicic Acid (Hydro Fluosilic Acid) 120Formaldehyde 150Formaldehyde 35 150Formaldehyde 50 150Formic Acid 120Freon 11 (MF) 73Freon 12 73Freon 22 73Fructose 180Fruit Juice 180Fruit Pulp 180Fuel Oil NRFurfural (Ant Oil) Bran Oil NRGallic Acid 73Gas, Natural 73Gasoline, Leaded NRGasoline, Sour NRGasoline, Unleaded (1 Dry) NR

Gelatin 180Gin 120Glucose 180Glue 120Glycerine (see Glycerol) NRGlycerol (Glycyl Alcohol) 180Glycolic Acid 150Glycols 120Grape Sugar 120Green Liquor (Alkaline pulp) 73Heptane 73Hexane 73Hexyl Alcohol (Hexanol) 73Honey 180Hydraulic Oil NRHydraulic Oil (synthetic) NRHydrazine NRHydrobromic Acid 10 150Hydrobromic Acid 20 150Hydrobromic Acid 48 120Hydrochloric Acid 10 180Hydrochloric Acid 20 160Hydrochloric Acid 25 160Hydrochloric Acid (Muriatic Acid) 37 120Hydrocyanic Acid 150Hydrocyanic Acid (Prussic Acid) 10 73Hydrofluoric Acid 10 150Hydrofluoric Acid 20 150Hydrofluoric Acid 30 120Hydrofluoric Acid 40 120Hydrofluoric Acid 50 73Hydrofluoric Acid 65 73Hydrofluoric Acid 75 73Hydrofluosilicic Acid 20 120Hydrofluosilicic Acid 120Hydrogen 73Hydrogen Cyanide 73Hydrogen Fluoride 73Hydrogen Peroxide 5 73Hydrogen Peroxide 10 73Hydrogen Peroxide 30 73Hydrogen Peroxide 50 73Hydrogen Peroxide 90 NRHydrogen Peroxide NRHydrogen Phosphide (see Phosphine) 73Hydrogen Sulfide 150Hydrogen Sulfide (Ag Sol) 150Hydrogen Sulfide (dry) 150Hydroquinone 150Hydroxyacetic Acid 150Hydroxylamine Sulfate 120Hypochlorous Acid 120

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Chemical Resistance of Polypropylene and Polyethylene

Acid Waste Piping Systems ORION FITTINGS, INC. 53

Page 54: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Iodine Solution 73Isoctane 73Isopropyl Ether NRJet Fuel JP-3 NRJet Fuel JP-4 NRJet Fuel JP-5 NRKerosene 73Ketones 73Kraft Liquor 73Lactic Acid (Milk Acid) 150Lard Oil 73Lauric Acid 120Lauryl Chloride NRLead Acetate (Sugar of Lead) 180Lead Chloride 150Lead Nitrate 150Lead Sulfate 150Lemon Oil NRLime-Sulfur Solution 120Linoleic Acid (Linolic Acid) 120Linseed Oil (Flaxseed Oil) 150Lubricating Oil 73Machine Oil 120Magnesium Carbonate 180Magnesium Chloride 180Magnesium Citrate 180Magnesium Hydroxide 180Magnesium Nitrate 180Magnesium Sulfate (Epsom Salts) 180Maleic Acid 120Malic Acid (Apple Acid) 73Manganese Sulfate 180Mercuric Chloride 180Mercuric Cyanide 180Mercuric Nitrate 120Mercuric Sulfate 120Mercurous Nitrate 120Mercury (Quicksilver) 150Methane (Methyl Hydride) 120Methanol (see Alcohol, Methyl) -Methyl Alcohol 180Methyl Benzene (see Toluene) -Methyl Bromide NRMethyl Butyl Ketone NRMethyl Cellosolve 73Methyl Chloride (Chloromethane) NRMethyl Chloroform (Trichloroethane) NRMethyl Ethyl Ketone (MEK) 73Methyl Isobutyl Ketone NRMethyl Methacrylale NRMethyl Salicylate (Wintergreen 011) 73Methyl Sulfate 73

Chemical Resistance of Polypropylene and Polyethylene

Methylene Chloride NRMethylene Iodine NRMilk 180Mineral Oil 73Molasses 120Monoethanolamine 150Naphtha 120Naphthalene (Tar Camphor) NRNatural Gas 73Nickel Acetate 180Nickel Chloride 180Nickel Nitrate 180Nickel Sulfate 180Nicotine NRNicotine Acid (see Niacin) 73Nitric Acid 10 150Nitric Acid 20 140Nitric Acid 30 120Nitric Acid 40 120Nitric Acid 50 73Nitric Acid 70 NRNitric Acid Concentrate 100 NRNitric Acid Fuming (Red) NRNitroglycerine NRNitrous Oxide NROcenolol (Oleyl Alcohol) NROctane NROils

120Oils, Citric 73Oils, Clove 73Oils, Coconut 120Oils, Cod liver 73Oils, Corn 73Oils, Cotton Seed 120Oils, Creosote NROils, Crude Sour 73Oils, Diesel Fuel 73Oils, Fuel 73Oils, Linseed 150Oils, Mineral 120Oils, Olive 150Oils, Silicone 150Oils, Vegetable 73Oleic Acid (Red Oil) 73Oleum (Fuming Sulfuric Acid) NROxalic Acid 73Oxygen Gas NROzonized Water NRPalmitic Acid 10 180Palmitic Acid 70 180Peracetic Acid 40 NR

54 ORION FITTINGS, INC. Acid Waste Piping Systems

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Page 55: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Perchloric Acid 70 180Petroleum (Sour) 73Petroleum Oils 73Phanois (Carbolic Acid) 73Phenylhydrazine NRPhosgene Gas NRPhosgene Liquid NRPhosphoric Acid 10 180Phosphoric Acid 20 180Phosphoric Acid 40 180Phosphoric Acid 50 180Phosphoric Acid 80 180Phosphoric Acid 85 180Phosphorus Oxychloride 73Phosphorus Trichloride, dry 73Photographic Developer 150Photographic Solutions 150Phthalic Acid (Terephthalic Acid) NRPhthalic Anhydride NRPickle Brine 120Pickling Solutions 150Plating Solutions, Antimony 120Plating Solutions, Arsenic 120Plating Solutions, Brass 120Plating Solutions, Bronze 120Plating Solutions, Cadmium 120Plating Solutions, Chrome 120Plating Solutions, Copper 180Plating Solutions, Gold 120Plating Solutions, Indium 120Plating Solutions, Iron 120Plating Solutions, Lead 120Plating Solutions, Nickel 180Plating Solutions, Rhodium 150Plating Solutions, Silver 180Plating Solutions, Tin 180Plating Solutions, Zinc 180Polyethylene Glycol Emulsion 180Polyvinyl Alcohol 120Potash Potassium Carbonate 180Potassium Aluminum Sulfate 180Potassium Bicarbonate 180Potassium Bichromate (see Potassium Dichromate)

150Potassium Bisulfate 180Potassium Bromate 120Potassium Bromide 30 180Potassium Carbonate 180Potassium Chlorate Aqueous 30 180Potassium Chloride 180Potassium Chromate 180Potassium Copper Cyanide 150

Potassium Dichromate 180Potassium Ferricyanide 180Potassium Ferrocyanide 180Potassium Fluoride 180Potassium Hydroxide (Caustic Potash) 180Potassium Perbotate 150Potassium Perchlorate 150Potassium Permanganate 20 73Potassium Persulfate 120Potassium Pitrate 150Potassium Sulfate 180Potassium Sulfide 120Propane (Dimethyl-Methane) 73Salenic Acid 73Salt Brine 180Sea Water 180Silver Cyanide 180Silver Nitrate 180Silver Salts 180Silver Sulfate 150Soap Solutions 180Soda Ash (Sodium Carbonate) 180Sodium Acetate 180Sodium Alum 150Sodium Benzoate 180Sodium Bicarbonate 180Sodium Bisulfate 180Sodium Bisulfite 180Sodium Borate (Borax) 120Sodium Bromide 180Sodium Carbonate (Soda Ash) 180Sodium Chlorate 180Sodium Chloride (Salt) 180Sodium Chlorite 150Sodium Cyanide 180Sodium Dichromate 180Sodium Ferricyanide 150Sodium Ferrocyanide 150Sodium Fluoride 180Sodium Hydroxide 15 180Sodium Hydroxide 20 180Sodium Hydroxide 30 180Sodium Hydroxide 50 180Sodium Hydroxide 70 180Sodium Hydroxide Conc (Caustic Soda) 180Sodium Hypochlorite (Bleach) 12.5 120Sodium Hypochlorite Conc 20 73Sodium Metaphosphate 150Sodium Metasilicate 150Sodium Nitrate 180Sodium Paimitale 120Sodium Perborate 180

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Chemical Resistance of Polypropylene and Polyethylene

Acid Waste Piping Systems ORION FITTINGS, INC. 55

Page 56: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Sodium Peroxide 180Sodium Phosphate Acid 180Sodium Phosphate Alkaline (Mono Basic) 180Sodium Phosphate Neutral (Tri Basic) 180Sodium Silicate (Water Glass) 180Sodium Sulfate 180Sodium Sulfide 180Sodium Sulfite 180Sodium Thiocyanate 150Sodium Thiosulfate 180Soybean Oil 120Stannic Chloride (Tin Chloride) 150Stannous Chloride (Tin Salts) 150Stearic Acid 120Stoddard Solvent (Dry Cleaning Solvent) 73Succinic Acid (Butanedioic Acid) 150Suffonated Detergents 120Sugar Solutions 180Sulfamic Acid NRSulfate Liquors (Paper Pulp) 150Sulfur 73Sulfur Chloride NRSulfur Dioxide (Dry) 73Sulfur Dioxide (Wet) 73Sulfuric Acid 10 180Sulfuric Acid 30 150Sulfuric Acid 50 73Sulfuric Acid 60 73Sulfuric Acid 70 73Sulfuric Acid 80 NRSulfuric Acid 90 NRSulfuric Acid 95 NRSulfuric Acid 100 NRSulfurous Acid 150Tall Oil 180Tannic Acid 180Tartaric Acid (Dihydrxy Succinic Acid) 150Tatralin (Tetrahydro-Naphthalene) NRTetrachlorethane NRThionyl Chloride NRThread Cutting Oils 120Titanium Teirachloride NRToluene NRTransformer Oil (Liquid Insulators)

Mineral Oil Type 73Tributyl Phosphate 73Trichlorethylene 73Trichloroacetic Acid 73Trichloroethane (Methyl Chloroform) NRTriethanolamine NRTriethylamine NRTrisodium Phosphate 120

Chemical Resistance of Polypropylene and Polyethylene

Turpenline NRUrea 180Urine 180Vaseline 150Vegetable Oil 120Vinegar (4-8% Acetic Acid) 150Vinyl Ether NRWater Acid Mine 150Water Deionized 180Water Demineralized 180Water Distilled 180Water Potable 180Water Salt 180Water Sewage 180Whiskey 180White Liquor 73Wines 150Xylene NRZinc Chloride 180Zinc Nitrate 180Zinc Sulfate 180

56 ORION FITTINGS, INC. Acid Waste Piping Systems

Chemical Substance Concentration TemperatureºF Chemical Substance ConcentrationTemperatureºF

Page 57: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acetaldehyde NRAcetamide 75 25Acetic Acid 120 50Acetic Acid 10% in water 225 110Acetic Acid 50% in water 200 95Acetic Acid 80% in water 150 65Acetic Anhydride NRAcetone NRAcetone 10% in water 125 50Acetonitrile 125 50Acetophenone NRAcetyl Bromide 125 50Acetyl Chloride 125 50Acetylacetone NRAcetylene 250 120Acrylonitrile 75 25Adipic Acid 150 65Air 275 135Alcoholic Spirits 40% Ethyl Alcohol 200 95Allyl Alcohol 125 50Allyl Chloride 212 100Aluminum Acetate Aqueous solution or solid 275 135Aluminum Bromide 275 135Aluminum Chloride Up to 40% in water 275 135Aluminum Fluoride Aqueous solution or solid 275 135Aluminum Hydroxide 275 135Aluminum Nitrate Aqueous solution or solid 275 135Aluminum Oxychloride 275 135Aluminum Sulfate Aqueous solution or solid 275 135Ammonia, gas NRAmmonia, Liquid NRAmmonium Acetate Aqueous solution or solid 175 80Ammonium Alum Aqueous solution or solid 275 135Ammonium Bifluoride Aqueous solution or solid 150 65Ammonium Bromide Aqueous solution or solid 250 120Ammonium CarbonateAqueous solution or solid 275 135Ammonium Chloride Aqueous solution or solid 275 135Ammonium DichromateAqueous solution or solid 250 120Ammonium Fluoride Aqueous solution or solid 275 135Ammonium Hydroxide Up to “concentrated” 225 110Ammonium

Metaphosphate Aqueous solution or solid 275 135Ammonium Nitrate Aqueous solution or solid 275 135Ammonium Persulfate Aqueous solution or solid 75 25

Ammonium PhosphateAqueous solution or solid 275 135Ammonium Sulfate Aqueous solution or solid 275 135Ammonium Sulfide Aqueous solution or solid 125 50Ammonium ThiocyanateAqueous solution or solid 275 135Amyl Acetate 125 50Amyl Alcohol 275 135Sec-Amyl Alcohol 125 50Amyl Chloride 275 135Aniline 120 50Aniline Hydrochloride Aqueous solution or solid 75 25Aqua Regia 75 25Arsenic Acid Aqueous solution 275 135Asphalt 250 120Barium Carbonate 275 135Barium Chloride Aqueous solution or solid 275 135Barium Hydroxide 275 135Barium Nitrate Aqueous solution or solid 275 135Barium Sulfate 275 135Barium Sulfide 275 135Beer 212 100Beet Sugar Liquors 225 110Benzaldehyde 70 20Benzene 170 75Benzenesulfonic Acid Aqueous solution or solid 125 50Benzoic Acid 225 110Benzoyl Chloride 170 75Benzoyl Peroxide 170 75Benzyl Alcohol 250 120Benzyl Chloride 275 135Benzyl Ether 100 40Benzylamine Aqueous solution or liquid 75 25Black Liquor 175 80Bleaching Agents 275 135Borax 275 135Boric Acid 275 135Boron Trifluoride 75 25Brine 275 135Brine, acid 275 135Brine, basic 275 135Brine, chlorinated acid 200 95Bromic Acid Aqueous solution 200 95Bromine dry gas 150 65Bromine, liquid 150 65Bromine, Water 212 100

The information appearing here has been assembled from sources believed to be reliable, but is not guaranteed by Orion. Orion is not respon-sible for its accuracy or reliabilty. In manufacturing its products, Orion uses raw materials manufactured by others, and Orion has no control over themethods used in installing its products or the conditions under which they are used. It does not make any representation concerning either the chem-ical resistance properties of its products or the toxicological effects of chemicals reacting with them. Nothing appearing here should be consideredas a recommendation for any use that would infringe patent rights or an endorsement for the use of any particular material or chemical or any classof materials or chemicals.apure substance unless otherwise indicated btemperatures in ºF have been rounded to ºC in 5 degree increments cNR indicates that KYNAR resin is not recommmended for use with the chemical at room temperature or at the temperature indicated

Maximumb Maximumb

Temperature Temperature

Chemical Resistance of PVDF

Acid Waste Piping Systems ORION FITTINGS, INC. 57

Page 58: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Bromobenzene 150 65Bromoform 150 65m-Bromotoluene 175 80Butadiene 250 120Butane 250 120Butanediol Aqueous solution or liquid 275 135Butyl Acetate 80 25Butyl Acrylate 125 50Butyl Alcohol Aqueous solution or liquid 225 110sec-Butyl Alcohol Aqueous solution or liquid 200 95t-Butyl Alcohol Aqueous solution or liquid 200 95Butyl Bromide 275 135Butyl Chloride 275 135Butyl Ether 100 40Butyl Mercaptan 275 135Butyl Stearate 100 40Butylamine Aqueous solution or liquid NRsec-Butylamine Aqueous solution or liquid 70 20t-Butylamine Aqueous solution or solid 70 201 -Butylene 275 135Butylphenol 225 110Butyraidehyde 150 65Butyric Acid 225 110Calcium Acetate Aqueous solution or solid 275 135Calcium Bisulfate Aqueous solution or solid 285 135Calcium Bisulfite Aqueous solution or solid 200 95Calcium Bromide Aqueous solution or solid 275 135Calcium Carbonate 275 135Calcium Chlorate Aqueous solution or solid 275 135Calcium Chloride Aqueous solution or solid 275 135Calcium Hydroxide 275 135Calcium Hypochlorite Aqueous solution or solid 200 95Calcium Nitrate Aqueous solution or solid 275 135Calcium Oxide 250 120Calcium Phosphate 275 135Calcium Sulfate 275 135Cane Sugar Liquors 275 135Caprylic Acid 175 80Carbon Dioxide 275 135Carbon Disulfide 75 25Carbon Monoxide 275 135Carbon Tetrachloride 275 135Carbonic Acid 275 135Casein 250 120Castor Oil 275 135Chloral Hydrate 75 25Chlorinated Phenol 150 65Chlorine 5% in CCI4 200 95Chlorine, gas 200 95Chlorine, liquid 200 95Chlorine Dioxide 150 65Chlorine Water 225 110

Chemical Resistance of PVDF

Chloroacetic Acid Aqueous solution or pure NRChloroacetyl Chloride 125 50Chlorobenzene 170 75Chlorobenzene-sulfonic

Acid Aqueous solution or pure 200 95Chlorobenzyl Chloride 125 50Chlorofluorocarbon 11 200 95Chlorofluorocarbon 12 200 95Chlorofluorocarbon 13 200 95Chlorofluorocarbon 14 200 95Chlorofluorocarbon 21 200 95Chlorofluorocarbon 22 200 95Chlorofluorocarbon 113 200 95Chlorofluorocarbon 114 200 95Chloroform 125 506-Chlorohexanol 170 75Chlorohydrin 125 50Chloropicrin 150 65Chlorosulfonic Acid NRChlorotrimethylsilane 125 50Chrome Alum Aqueous solution or solid 200 95Chromic Acid Up to 40% in water 175 80Chromic Acid 50% in water 125 50Chromyl Chloride 125 50Cider 140 60Citric Acid Aqueous solution or solid 275 135Coal Gas 225 110Coconut Oil 275 135Copper Acetate Aqueous solution or solid 250 120Copper Carbonate, basic 275 135Copper Chloride Aqueous solution or solid 275 135Copper Cyanide 275 135Copper Fluoride 275 135Copper Nitrate Aqueous solution or solid 275 135Copper Sulfate Aqueous solution or solid 275 135Corn Oil 275 135Corn Syrup 250 120Cottonseed Oil 275 135Cresol 150 65Cresylic Acid 150 65Crotonaldehyde 125 50Crude Oil 275 135Cryolite 250 120Cuprous Chloride 250 120Cyclohexane 275 135Cyclohexanol 150 65Cyclohexanone 75 25Cyclohexyl Acetate 200 95Decane 250 120Dextrin Aqueous solution or solid 250 120Diacetone Alcohol 75 25p-Dibromobenzene 200 95

58 ORION FITTINGS, INC. Acid Waste Piping Systems

Maximumb Maximumb

Temperature TemperatureChemical Substance Concentration ºF ºC Chemical Substance Concentration ºF ºC

Page 59: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

1,2,-Dibromopropane 200 95Dibutyl Phthalate NRDibutyl Sebacate NRDibutylamine Aqueous solution or liquid 70 20Dichloroacetic Acid Aqueous solution or liquid 125 50o-Dichlorobenzene 150 65Dichlorodimethylsilane 125 50Dichloroethylene 225 1102,2,-Dichloropropionic Acid 125 50aa-Dichlorotoluene 150 65Diesel Fuels 275 135Diethanolamine Aqueous solution or liquid NRDiethylamine Aqueous solution or liquid 75 25Diethyl Malonate NRDiethylenetriamine Aqueous solution or liquid 125 50Diglycolic Acid 75 25Diisobutyl Ketone 200 95Diisobutyene 275 135Diisopropyl Ketone 125 50Dimethyl Acetamide NRDimethyl Formamide NRDimethyl Phthalate 75 25Dimethyl Sulfate 75 25Dimethyl Sulfoxide NR2,6,-Dimethyl-4-heptanol 200 952,5,-Dimethyl-1,5-hexadiene 250 120Dimethylamine Aqueous solution or gas 75 25Dimethylaniline 75 25Dioctyl Phthalate 75 251,4-Dioxane NRDioxolane NRDipropylene Glycol Methyl Ether 75 25Disodium Phosphate Aqueous solution or solid 200 95Divinyl Benzene 125 50Epichlorohydrin NREpsom Salts Aqueous solution or solid 200 95Ethanethiol 75 25Ethanolamine Aqueous solution or liquid NR2-Ethoxyethyl Acetate Aqueous solution or liquid 200 95Ethyl Acetate NREthyl Acetoacetate 75 25Ethyl Acrylate 75 25Ethyl Alcohol Aqueous solution or liquid 275 135Ethyl Chloride 275 135Ethyl Chloroacetate 75 25Ethyl Chloroformate 125 50Ethyl Cyanoacetate 75 25Ethyl Ether 125 50Ethyl Formate 75 25Ethylbenzene 125 50Ethylene ChlorohydrinAqueous solution or liquid 75 25Ethylene Dichloride 275 135

Ethylene Glycol Aqueous solution or liquid 275 135Ethylene Oxide 200 95Ethylenediamine Aqueous solution or liquid 225 1102-Ethyl-1-hexanol 250 120Fatty Acids 275 135Fatty Acids, Sulfonates 175 80Ferric Chloride Aqueous solution or solid 275 135Ferric Hydroxide 250 120Ferric Nitrate Aqueous solution or solid 275 135Ferric Sulfate 275 135Ferric Sulfide 250 120Ferrous Chloride Aqueous solution or solid 275 135Ferrous Hydroxide 250 120Ferrous Nitrate Aqueous solution or solid 275 135Ferrous Sulfate 275 135Fluorine 75 25Fluoroboric Acid Aqueous solution 275 135Fluosilicic Acid 275 135Formaldehyde 37% in water 125 50Formic Acid Aqueous solution or liquid 250 120Fructose Aqueous solution or solid 275 135Fruit Juices, Pulp 212 100Fuel Oil 275 135Fumaric Acid 170 65Furan NRFurfural 75 25Furfuryl Alcohol Aqueous solution or liquid 100 40Gallic Acid 75 25Gas, manufactured 275 135Gas, natural 275 135Gasoline, leaded 275 135Gasoline, sour 275 135Gasoline, unleaded 275 135Gelatin 250 120Gin 200 95Glucose Aqueous solution or solid 275 135Glue 250 120Glutamic Acid 200 95Glycerin Aqueous solution or liquid 275 135Glycine Aqueous solution or solid 75 25Glycolic Acid 75 25Heptane 275 135Hexachloro-1,3-butadiene 125 50Hexamethylenediamine NR NRHexamethylphosphotriamide NRHexane 275 135Hexyl Alcohol 175 80Hydrazine Aqueous solution or liquid 200 95Hydrazine

Dihydrochloride Aqueous solution or solid 75 25Hydrazine Hydrate Aqueous solution or liquid 125 50Hydriodic Acid Aqueous solution 275 135

Maximumb Maximumb

Temperature TemperatureChemical Substance Concentration ºF ºC Chemical Substance Concentration ºF ºC

Chemical Resistance of PVDF

Acid Waste Piping Systems ORION FITTINGS, INC. 59

Page 60: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Hydrobromic Acid Up to 50% in water 275 135Hydrochloric Acid Up to “concentrated” 275 135Hydrocyanic Acid Aqueous solution 275 135Hydrofluoric Acid Up to 40% in water 250 120Hydrofluoric Acid 41 -100% in water 200 95Hydrogen 275 135Hydrogen Chloride 275 135Hydrogen Cyanide 275 135Hydrogen Fluoride 200 95Hydrogen Peroxide Up to 30% in water 200 95Hydrogen Peroxide 90% in water 70 20Hydrogen Sulfide 275 135Hydrogen Sulfide Aqueous solution 225 110Hydroquinone 250 120Hypochlorous Acid Aqueous solution 70 20Iodine 10% in Non-Aqueous solvent 150 65Iodine, gas 150 65Iodoform 200 95Isoamyl Ether 250 120Isobutyl Alcohol 250 120Isooctane 250 120Isophorone 175 80Isopropyl Alcohol Aqueous solution or liquid 140 60Isopropyl Chloride 100 40Isopropyl Ether 125 50Isopropylbenzene 100 40Jet Fuel (JP4, JP5) 200 95Kerosene 275 135Lactic Acid Aqueous solution or pure 125 50Lanolin 250 120Lard Oil 275 135Lauric Acid 225 110Lauroyl Chloride 250 120Lauryl Mercaptan 200 95Lauryl Sulfate 250 120Lead Acetate Aqueous solution or solid 275 135Lead Chloride 250 120Lead Nitrate Aqueous solution or solid 250 120Lead Sulfate 250 120Lemon Oil 250 120Linoleic Acid 250 120Linseed Oil 275 135Lithium Bromide Aqueous solution or solid 225 110Lithium Chloride Aqueous solution or solid 250 120Lubricating Oil 275 135Magnesium Carbonate 275 135Magnesium Chloride Aqueous solution or solid 275 135Magnesium Citrate 250 120Magnesium Hydroxide 275 135Magnesium Nitrate Aqueous solution or solid 275 135Magnesium Sulfate Aqueous solution or solid 275 135Maleic Acid Aqueous solution or solid 250 120

Chemical Resistance of PVDF

Maleic Anhydride 75 25Malic Acid Aqueous solution or solid 250 120Manganese Sulfate Aqueous solution or solid 250 120Mercuric Chloride 250 120Mercuric Cyanide 250 120Mercuric Nitrate Aqueous solution or solid 275 135Mercury 275 135Methacrylic Acid 125 50Methane 275 135Methanesulfonic Acid Aqueous solution or liquid 200 95Methyl Acetate 100 40Methyl Acrylate 100 40Methyl Alcohol Aqueous solution or liquid 275 135Methyl Bromide 275 135Methyl Chloride 275 135Methyl Chloroacetate 75 25Methyl Chloromethyl Ether 75 25Methyl Ethyl Ketone NRMethyl lsobutyl Ketone NRMethyl Methacrylate 125 50Methyl Salicylate 150 65Methylamine NRMethylchloroform 125 50Methylene Bromide 175 80Methylene Chloride 125 50Methylene Iodide 200 95Methylsulfuric Acid Aqueous solution or liquid 125 50Methyltrichlorosilane 150 65Milk 250 120Mineral Oil 275 135Molasses 175 80Morpholine Aqueous solution or liquid 75 25Motor Oil 275 135Naphtha 275 135Naphthalene 200 95Nickel Acetate Aqueous solution or solid 250 120Nickel Chloride Aqueous solution or solid 275 135Nickel Nitrate Aqueous solution or solid 275 135Nickel Sulfate Aqueous solution or solid 275 135Nicotine 70 20Nicotinic Acid 250 120Nitric Acid Up to 10% in water 175 80Nitric Acid 11 - 70% in water 125 50Nitric Acid ”Concentrated” NRNitric Acid, fuming NRNitrobenzene 75 25Nitroethane 70 20Nitrogen 275 135Nitrogen Dioxide 170 75Nitroglycerin 125 50Nitromethane 120 50Nitrotoluene 175 80

60 ORION FITTINGS, INC. Acid Waste Piping Systems

Maximumb Maximumb

Temperature TemperatureChemical Substance Concentration ºF ºC Chemical Substance Concentration ºF ºC

Page 61: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Nitrous Oxide NROctane 275 135Octene 275 135Oleic Acid 250 120Oleum NROlive Oil 250 120Oxalic Acid 125 50Oxygen 275 135Ozone 225 110Palm Oil 200 95Palmitic Acid 250 120Paraffin 250 120Paraffin Oil 250 120Peanut Oil 250 120Perchloric Acid 10% in water 200 95Perchloric Acid 70% in water 125 50Perchloroethylene 275 135Perchloromethyl Mercaptan 125 50Petrolatum 275 140Petroleum 275 135Phenol 5% in water 175 80Phenol 125 501-Phenol-2-sulfonic Acid 125 50Phenyl Ether 125 50Phenylhydrazine 125 50Phenylhydrazine

Hydrochloride Aqueous solution or solid 125 50o-Phenylphenol 175 80Phosgene 175 80Phosphoric Acid Less than 85% in water 275 135Phosphoric Acid 85% in water 225 110Phosphorus, red 75 25Phosphorus, Oxychloride NRPhosphorus, Pentachloride 200 95Phosphorus, Pentoxide 200 95Phosphorus, Trichloride 200 95Phthalic Acid 200 95Picric Acid 75 25Plating Solutions: Brass 200 95Cadmium 200 95Chrome 200 95Copper 200 95Iron 200 95Lead 200 95Nickel 200 95Rhodium 200 95Silver 200 95Speculum 200 95Tin 200 95Zinc 200 95Polyethylene Glycol 200 95Polyvinyl Acetate 275 135

Maximumb Maximumb

Temperature TemperatureChemical Substance Concentration ºF ºC Chemical Substance Concentration ºF ºC

Chemical Resistance of PVDF

Acid Waste Piping Systems ORION FITTINGS, INC. 61

Polyvinyl Alcohol 275 135Potassium NRPotassium Acetate Aqueous solution or solid 275 135Potassium Alum Aqueous solution or liquid 275 135Potassium Aluminum Chloride 275 135Potassium BicarbonateAqueous solution or solid 200 95Potassium Bisulfate Aqueous solution or solid 275 135Potassium Borate Aqueous solution or solid 275 135Potassium Bromate Aqueous solution or solid 275 135Potassium Bromide Aqueous solution or solid 275 135Potassium Carbonate Aqueous solution or solid 275 135Potassium Chlorate 200 95Potassium Chloride Aqueous solution or solid 275 135Potassium Chromate Aqueous solution or solid 275 135Potassium Cyanide Aqueous solution or solid 275 135Potassium Dichromate 275 135Potassium FerricyanideAqueous solution or solid 275 135Potassium FerrocyanideAqueous solution or solid 275 135Potassium Fluoride Aqueous solution or solid 275 135Potassium Hydroxide 5 to 10% in water NRPotassium Hydroxide Greater than 50% in water NRPotassium Hypochlorite Aqueous solution 200 95Potassium Iodide Aqueous solution or solid 250 120Potassium Nitrate Aqueous solution or solid 275 135Potassium Perborate 275 135Potassium Perchlorate 200 95Potassium PermanganateAqueous solution or solid 250 120Potassium Persulfate 125 50Potassium Sulfate Aqueous solution or solid 275 135Potassium Sulfide 275 135Propane 275 135Propyl Acetate 100 40Propyl Alcohol Aqueous solution or liquid 150 65Propylamine NRPropylene Dibromide 200 95Propylene Dichloride 200 95Propylene Glycol Aqueous solution or liquid 150 65Propylene Oxide NRPyridine NRPyrogallol Aqueous solution or solid 120 50Salicylaldehyde 125 50Salicylic Acid 200 95Selenic Acid Aqueous solution or pure 150 65Silicon Tetrachloride 125 50Silicone Oil 250 120Silver Cyanide 275 135Silver Nitrate Aqueous solution or solid 275 135Silver Sulfate 250 120Sodium NRSodium Acetate Aqueous solution or solid 275 135Sodium Amalgam NRSodium Benzoate Aqueous solution or solid 275 135

Page 62: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Sodium Bicarbonate Aqueous solution or solid 275 135Sodium Bisulfate Aqueous solution or solid 275 135Sodium Bisulfite Aqueous solution or solid 275 135Sodium Bromate Aqueous solution or solid 200 95Sodium Bromide Aqueous solution or solid 275 135Sodium Carbonate Aqueous solution or solid 275 135Sodium Chlorate Aqueous solution or solid 250 120Sodium Chlorite Aqueous solution or solid 250 120Sodium Chromate Aqueous solution or solid 200 95Sodium Cyanide Aqueous solution or solid 275 135Sodium Dichromate Aqueous solution or solid 200 95Sodium Dithionite Aqueous solution or solid 100 40Sodium Ferricyanide Aqueous solution or solid 275 135Sodium Ferrocyanide Aqueous solution or solid 275 135Sodium Fluoride Aqueous solution or solid 285 135Sodium Fluosilcate 200 95Sodium Hydrogen

Phosphate Aqueous solution or solid 250 120Sodium Hydroxide Up to 10% in water 100 40Sodium Hydroxide Greater than 50% in water NRSodium Hypochlorite Up to 5% in water 275 135Sodium Hypoclorite 6–15% in water 200 95Sodium Iodide Aqueous solution or solid 275 135Sodium Nitrate Aqueous solution or solid 275 135Sodium Nitrite Aqueous solution or solid 275 135Sodium Palmitate 250 120Sodium Perchlorate Aqueous solution or solid 250 120Sodium Peroxide 200 95Sodium Phosphate Aqueous solution or solid 275 135Sodium Thiocyanate Aqueous solution or solid 250 120Sodium Thiosulfate Aqueous solution or solid 275 135Sour Crude Oil 275 135Soy Bean Oil 250 120Stannic Chloride Aqueous solution or solid 275 135Stannous Chloride Aqueous solution or solid 275 135Starch 200 95Stearic Acid 275 135Stilbene 175 80Styrene 180 85Succinic Acid 150 65Sugar Syrup 275 135Sulfur 250 120Sulfur Cloride 75 25Sulfur Dichloride 75 25Sulfur Dioxide 175 80Sulfur Trioxide NRSulfuric Acid Up to 60% in water 250 120Sulfuric Acid 80 - 93% in water 200 95Sulfuric Acid 98% in water 150 65Sulfuric Acid, fuming NRSulfuryl Chloride NRSulfuryl Fluoride 75 25Tall Oil 275 135Tallow 275 135Tannic Acid 225 110

Tar 250 120Tartaric Acid Aqueous solution or solid 250 1201,1,2,2,-Tetrabromoethane 250 1201,1,2,2,-Tetrachloroethane 250 1202,3,4,6,-Tetrachlorophenol 150 65Tetraethyllead 275 135Tetrahydrofuran Aqueous solution or liquid NRTetramethylammonium

Hydroxide Up to 10% in water 200 95Tetramethylurea NRThioglycol 75 25Thioglycolic Acid 175 80Thionyl Chloride NRThiophosphoryl Chloride NRThread Cutting Oils 200 95Titanium Tetrachloride 150 65Toluene 175 80Toluenesulfonyl Chloride 125 50Tomato Juice 212 100Tributyl Phosphate 75 25Trichloroacetic Acid Up to 10% in water 200 95Trichloroacetic Acid 50% in water to pure 125 501,2,4,-Trichlorobenzene 200 951,1,2,-Trichloroethane 150 65Trichloroethylene 275 1352,4,5,-Trichlorophenol 150 65Tricresyl Phosphate NRTriethanolamine Aqueous solution or liquid 125 50Triethyl Phosphate NRTriethylamine 125 50Trifluoroacetic Acid 50% in water 200 95Trifluoroacetic Acid 125 50Trimethylamine Aqueous solution or gas 150 65Turpentine 275 135Urea Aqueous solution or solid 250 120Varnish 250 120Varsol 250 120Vegetable Oil 275 135Vinegar 225 110Vinyl Acetate 250 120Vinyl Chloride 200 95Vinylidene Chloride 200 95Water 275 135Water, salt 275 135Water, sewage 250 120Whiskey 200 95Wine 200 95Xylene 200 95Zinc Acetate Aqueous solution 250 120Zinc Bromide Aqueous solution or solid 250 120Zinc Chloride Aqueous solution or solid 275 135Zinc Nitrate Aqueous solution or solid 275 135Zinc Sulfate Aqueous solution or solid 275 135

62 ORION FITTINGS, INC. Acid Waste Piping Systems

Chemical Resistance of PVDF

Maximumb Maximumb

Temperature TemperatureChemical Substance Concentration ºF ºC Chemical Substance Concentration ºF ºC

Page 63: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

Acid Waste Piping Systems ORION FITTINGS, INC. 63

Joint AssemblyMany of the questions you may have about

assembling Orion No-Hub/Plain End, socketfusion and electrofusion systems are answeredin this section. However if, after reading thissection you still have questions, please call ourtechnical department at (913) 342-1653, 8:00 am– 4:30 pm, Monday-Friday, Central Time.

Cold Weather Assembly

As with all types of plastic piping systems,installation in cold weather can be difficult andtherefore is not recommended at temperaturesbelow 40 degreesF unless proper precautionsare taken.

In cold weather installations, the area beinginstalled must be shielded from the wind andother outside elements and the joints must becovered with heating blankets, prior to beinginstalled.

If joints are installed in cold weather, they maybe difficult to seal. In addition, if above groundsystems are installed in cold temperatures andthe area is later heated; the system will expand,possibly causing undue stress on the entire sys-tem. In view of this, special care must be takenwhen designing and installing any plastic pipingsystem in cold weather. The above informationapplies to SocketFusion, Electrofusion and No-Hub/Plain End systems.

AssemblyAssembly

Page 64: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Assembly

64 ORION FITTINGS, INC. Acid Waste Piping Systems

No-Hub/Plain End Assembly

Grooving pipe in the fieldAlthough Orion’s Acid waste pipe is sup-

plied with factory grooves it may be necessaryto groove cut pipe sections in the field. Whenfield grooving is necessary, it is accomplishedquickly and simply with an Orion grooving tool.A tool kit containing all the tools you will needis available from Orion.

STEP 4Turn knob 1⁄4 turn clockwise, to 3 o’clock position.STEP 5Pushing against pipe, rotate tool clockwise twice aroundpipe. Maintain constant inward pressure against tool at

STEP 1Pipe to be used with the No-Hub/Plain End coupling mustbe cleanly cut with a thin wheel plastic tubing cutter toassure a clean square cut. STEP 2 Bevel and deburr the pipe with a deburring tool.The pipe must be beveled and deburred prior to groovingpipe.

handle during rotation.STEP 6Turn knob another 1⁄4 turn to 6 o’clock position. Proceed asin step 5, remembering to maintain constant inward pres-sure until no more material is removed from groove.

5

3 6

STEP 3With handle of grooving tool up, place knob on handle atthe top or 12 o’clock position.Insert tool fully onto pipe. Make sure pipe is touching thestop in the tool.

STEP 7Return knob to 12 o’clock position and remove tool frompipe. STEP 8Remove any burrs or material from groove edges. Seethat all excess material is removed from the grooving toolbefore grooving the next piece of pipe.

47

NOTE: DO NOT TESTANY ORION PIPING SYSTEM WITH COMPRESSED AIR ORGASSES. TEST HYDROSTATICALLY ONLY

Page 65: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 65

Acid Waste Assembly

No-Hub/Plain End Assembly

STEP 1Insert pre-grooved pipe or fitting into coupling until cou-pling rib snaps. This assures proper fit.

General Information:• Satisfactory installation requires careful

measurement.

• Cheating on pipe lengths will cause a bindallowing joints to leak even when fully tightened.

• Pipe must be kept clean. Mud, dirt or other foreignmatter in joints could cause leaks.

• Hanging specifications must be followed, takingcare to see that system is not clamped tightly inhangers. System must be free to move to allowfor thermal contraction and expansion. Westrongly recommend the use of an Orioninstallation kit for installing the system. This kithas been developed to furnish everythingnecessary for proper installation of the system.

• The below pictures demonstrate what is tytpicallythe proper tightness for the No-Hub/Plain Endcoupling as well as an example of over-tighteningand an example of insufficient tightening. Certainenvironmental conditions and/or manufacturingtolerances may require more or less tighteningthan is shown in the below examples.

STEP 2Position stainless steel band so equal amounts of innermaterial show on each side of band.

1

2

STEP 3Tighten bolts until coupling bars come together at the topand have a 1/16” to 1/8” gap at the bottom. Do not over-tighten. A standard 10" length x1/2” drive ratchet wrenchwith 6-point x1/2” socket is recommended.

3 Correctly Tightened

Too TightToo Loose

NOTE: DO NOT TESTANY ORION PIPING SYSTEM WITH COMPRESSED AIR ORGASSES. TEST HYDROSTATICALLY ONLY

Page 66: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

66 ORION FITTINGS, INC. Acid Waste Piping Systems

Turn on power switch on the RionfuserUnit and allow it to perform the automated self test.

Using the chart above mark thecorrect coupling depth on thepipe/fitting.Note: If using pipe, make sure to cutthe pipe straight and de-burr beforemarking the coupling depth.

Using 60 grit emery cloth,abrade the pipe/fitting areathat is to be fused.Note: Do not over-sand the pipe surface. Only abrade the pipeenough to remove the shiny sur-face of the pipe.

Insert the pipe/fitting com-pletely into the coupling. Verifythat the pipe/fitting is fullyseated into the coupling bymaking sure the edge of thecoupling is even with the markon the pipe from step 2.

The coupling fuses both sidesat once so repeat steps 2 thru 4for the other side of the coupling.

Once both sides of the couplinghas pipe/fitting properly seated,connect the Rionfuser leads tocoil terminals. Rionfuser will dis-play “Connect Leads” until theleads are attached.

Step 2 Step 3Step 1

Rionfuser Micro-Processor

Step 4 Step 5 Step 6

self test display

The instructions below are for installing the New Rionfuse CF system using the RIONFUSER electrofusionmicro-processor. It is up to the installing contractor to follow these guidelines and make practical

adjustments if necessary. If installing the Original Rionfuse system, please refer to Original Rionfuseinstallation instruction booklet.

Size Depth1-1/2” 1”2” 1”3” 1-3/8”4” 1-3/8”6” 2”8” 2-5/8”

RIONFUSE CF COUPLINGClamp-Free Design with Molded-In

electrofusion wire

Acid Waste Assembly Rionfuse CF

Page 67: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Fusion Cycle Fusion Cycle InformationInformation

Pipe Fusion FusionSize Time Current

1-1/2” 2:00 (2 min) 8.25 AMPS2” 2:00 (2 min) 8.25 AMPS3” 3:00 (3 min) 14.25 AMPS4” 3:00 (3 min) 14.25 AMPS6” 4:30 (4-1/2min) 19.00 AMPS8” 4:45 (4-3/4 min) 19.00 AMPS

10” 00000 000AMPS12” 00000 000AMPS

Note: If necessary, the Rionfuser has aMANUAL OVERRIDE function.

To perform this function, select the MANUAL OVERRIDE option

(Option #3 in the SELECT FITTINGSTYLE menu).

Step 8

As an alternative to pressing starton the control box, the installer canpress the start button on the outputleads. Fusion cycle information is shownto the right.The machine will automatically stopthe fusion process and sound anaudible alarm when the fusioncycle is complete. Disconnect theleads. Repeat steps 2-8 for additional fittings.

Step 7

Once continuity is confirmed, the display show SELECT FITTING STYLE (Rionfuse CF orOriginal) There is also a Manual Over-ride option. See manual override instruction pageswhen using that option.

Select Rionfuse CF. After selecting Rionfuse CF, the machine will ask you to select Size. Enter the correct size using the up/down arrows, then press start.

Once the proper size is selected, the Rionfuser will display, SELECT TYPE OF CYCLE . Under “Normal” environmental conditions, select Standard, then press start.

If ambient temperatures are below 50 degrees F, the joints must be preheated. In thiscase, select the PREHEAT cycle, then press start.Refer to the chart on page 3 for pre-heat instructions. If preheat is selected, theRionfuser will first preheat the joints and then automatically begin the standard fusion cycleafter a 2 minute “Heat Soak Time”. During the heat soak time, the unit will not be fusing thejoint, but the leads cannot be removed. If they are removed, the Rionfuser will stop thecycle and sound an audible alarm as well as display Error 112.

If the standard cycle is selected, the Rionfuser will automatically calculate the proper cur-rent and fusion time and will display the “Verify Weld Data” screen. If the weld data is cor-

Select Rionfuse CF.

Select SIZE.

Select TYPE of Cycle.

Example of ERROR 112

Disconnect Output Leads

Examples of Error Codes Error 108 Power Supply cut off Error 110 Fusion aborted by operatorError 112 Element Disconnecetd Error 128 Cannot maintain output current

Other error codes are possible. Please consult the Rionfuser manual or contact Orion for more information.Most errors are the result of incorrect power supply or the use of a bad generator. Do not use diesel weldinggenerators to power the Rionfuser unit. Standard 5000 watt generators used as a dedicated power source are typically sufficient.

Rionfuse CF Acid Waste Assembly

ORION FITTINGS, INC. 67

Page 68: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Rionfuse CF Multiple Jointing (# of FULL Couplings) Pipe Size: 1-1/2” 2” 3” 4” 6” 8” 10” 12”Max # of Couplings 3 3 2 2 1 1 1 1

In cold weather applications (below 50 degrees F) the joints should be pre-heated prior to performingthe standard fusion cycle. If the pre-heat cycle is used, the Rionfuser will automatically begin the stan-dard fusion cycle after a 2 minute heat soak cycle (machine will display a countdown timer during thistime). The Rionfuser automatically defaults to a 30 second pre-heat cycle, which is sufficient formany applications. However, due to a wide range of variables that occur in cold weather installations(wind, UV absorption, etc) additional pre-heat times may be necessary and it is up the the installingcontractor to determine what the proper pre-heat time is based on these varying field conditions.

The Rionfuser will promt the installer to select the Preheat/Warm UpCycle (Option #2)

The Rionfuser will display the preheat cycle remaining time (as wellas the weld number)

After completion of the preheat cycle, the Rionfuser will automaticallyswitch to the 2 minute heat soak time. After completion of the heat

soak cycle, the Rionfuser will automatically begin the standard fusion cycle.

The warm up time defaults to 30 seconds. This time can be changedby pressing the up/down arrows to the desired time, then press start.

Once the proper preheat time is entered, the Rionfuser will promptthe installer to verify the correct information prior to beginning thefusion cycle. If something is not correct, DO NOT START THEFUSION CYCLE.

Fusion should NOT be attempted below 30 degrees F. At very cold temperatures, heatshould be brought to the fusion area to bring it totemperatures above 30 degrees. In addition, all

material should be shielded from the wind and kept dry.

68 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Assembly Rionfuse CF

Cold Weather Assembly Guidelines forRionfuse CF

Page 69: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

PRECAUTIONS PRECAUTIONS AND AND ADDITIONALADDITIONAL INSTINSTALLAALLATION SUGGESTIONSTION SUGGESTIONS1. Installation is not recommended at ambient temperatures below 40 degrees F. If fusion is to be

performed at below 40 degrees, precautions must be made to be sure that the area is properly covered and heated.

2.Do not test with compressed air or gases. Test hydrostatically only. Typically a 10ft hydrostatic head pressure test is sufficient.

3.Store pipe and fittings out of direct sunlight. If material is to be stored outside, it should be cov-ered

with a black tarp and shielded from UV rays and kept dry.4.The Rionfuser has internal re-callibration capabilities. This unit will remind the user when it is time

for factory re-calibration (approximately every 2 years) This maintenance schedule must be strictlyfollowed to insure proper machine function.

5.Portable generators must be a minimum of 5kW and be dedicated to the Rionfuser Unit only. Diesel generators will NOT work.

6.The maximum allowable extension cord is 100 ft of 10 gauge wire.7.The Rionfuser unit allows for normal power variations. It is important to make sure that the power

source can supply a minimum of 100 volts (max of 150) before making Rionfuse joints. The Rionfuser will not start the fusion cycle if the supply voltage is not within 100-150 volts. If the Rionfuser cannot maintain output current due to drops in power supply during the fusion cycle, or there is a loss in continuity during the fusion cycle, the Rionfuser will end the cycle and sound anaudible alarm. If this occurs, the problem with the power source must be corrected (or thecontinuity fixed) before attempting to fuse any further joints. If power fluxuations or drops in power areallowed to continue, leaks in joints may occur as a result.

8. If a leak occurs, the system must be drained and the joints dried out. Re-connect the Rionfuser leads and fuse the joint using the warm up cycle setting (30 seconds). Upon completion of the warm up out cycle proceed to step 8 to re-start the standard fusion cycle.

9. Proper support of all joints must be achieved during the fusion and cooling cycles (approx10 minutes)

10. This brochure is meant to provide guidelines for fusing the Rionfuse CF system. Goodtypical plumbing installation practices as well as common sense should also be used. Whenin doubt, contact your local Orion Representative for installation suggestions.

In some rare instances, it may be necessary to manually override the Rionfuse unit in order to entertimes and/or currents that are not preset in the unit. The Manual Override function can also be used tofuse other materials-only if the fusion parameters (time and current) are known by the installer.

The basic instructions for using the manual override are as follows:1. When promted to SELECT FITTING STYLE (from step #7) select option #3 MANUAL OVERRIDE2. Enter the weld current for the fitting being fused by pressing the UP/DOWN arrows.

The weld current is shown in amps. Once current has been entered, press START.3. Enter the proper fusion time for the fitting being fused by pressing the UP/DOWN arrows. Once the

proper fusion time has been entered, press start.4. The machine will ask the installer to “Verify the Weld Data”. If the welding parameters shown on

the diplay are correct, press start to begin the “Manual” fusion cycle. At the end of the fusioncycle, the unit will stop the fusion and sound an audible alarm. Disconnect the leads and fuse another fitting if necessary.

Note: If the weld data is incorrect, do not begin the fusion cycle. Disconnect the leads and go back tostep #1. Also, pressing stop will cause the Rionfuser to go back one menu item.

Acid Waste Piping Systems ORION FITTINGS, INC. 69

Rionfuse CF Acid Waste Assembly

Page 70: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

70 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Assembly Socket Fusion

A socket fusion tool kit, including heat tool and various sizes of headsis available from Orion.

Note:• Make all field cuts of pipe square and true using a pipe cutter

designed for plastic pipe.• Make certain heads are installed properly on heat tool. Heads

are marked “M” and “F”, indicating male and female.• Bevel the leading edge of each pipe section with a 1/8” 45 degree

chamfer. This will minimize the amount of bead on the inside of thefitting when fused

STEP 2Measure depth of fitting. Subtract 1/16".

STEP 3Transfer measurement to pipe. Mark pipe with measurementobtained in Step 2.

3

1

4

STEP 1Check the heads for proper temperature (482 - 520°F or 250°- 270°C ). Ifnecessary, adjust the thermostat dial so that the 488°F Tempil stick burns,but the 525°F does not. NOTE: The newest Orion fusion tools mayhave a temperature dial in degrees celcius which has a maximumtemperature of 300°C. If this is the case, see temperature conversionchart below. Heat tools are factory set, however settings can vary due to factors such as weather, current variances, cord lengths, generators, etc.These variables should be checked on site. To increase tool temperature, turn dial “in” (clockwise). To decrease, turn screw “out” (counterclockwise). Step 6

Hold joint under pressure for 15 seconds to allow surfaces tofuse. Do not stress joint until fully cooled.

Clean any melted material from heater bushings using a cottonrag. Do not use abrasive materials to clean the heater bushings.

Confirm the heater bushings are the correct temperature beforefusing next joint.

The following chart shows the approximate time that the pipeand fitting should be held on the heater bushings. These timesare a guideline ony. It may be necessary to increase ordecrease times to obtain the correct meltconditions.

2

6

1-1/2” 2” 3” 4” 6”PP 12-15 sec 15-20 sec 20-25 sec 25-30 sec 30-35 secPVDF 12-15 sec 15-20 sec 20-25 sec 25-30 sec 30-35 sec

STEP 4Insert fitting on the male side of the heat tool. Then insertpipe on the female side. Do not insert past the mark onthe pipe.

Fusion Times in seconds

STEP 5Keep pipe and fitting absolutely straight on heat tool.

Use the chart below to determine how long to leave the pipe andfittings on the heater bushings.It should be noted that pipe andfittings will normally have a slight interference with the fusiontools. However, if the pipe and/or fittings do not fit tightly on theheater bushing, the heating time should be started when the components have swelled to just contact the surface of the bushing.

NOTE: DO NOT TEST NOTE: DO NOT TEST ANYANY ORION PIPING SYSTEM WITH COMPRESSED ORION PIPING SYSTEM WITH COMPRESSED AIR OR GASSES.AIR OR GASSES.TEST HYDROSTTEST HYDROSTAATICALLTICALLYY ONLONLYY

Temperature Conversion Factors

°F = Degrees in Farenheight°C = Degrees in Celcius(Centigrade)

°F = (°C x 1.8) + 32 °C= (°F - 32) x .555

°F °C122 50212 100300 150392 200482 250520 270572 300

Page 71: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 71

Slip Fit and Backwelding (Hot Gas Welding)

Welding Procedure

When a backwelding kit is purchased from Orion, acomplete booklet on Hot Gas welding is included. An overview of those welding procedures is summarizedbelow. (The following guidelines summarize the proce-dures used for backwelding with Orion’s speed tip

Line up the area or the two parts that are to be weld-ed together. Make sure that the surfaces are clean,oil and water free. Gently preheat the area where theweld is to be started by holding the Orion weldingGun near the surface and fanning the area. Nowfeed the welding rod into the preheat chamber of thespeed tip. This will start to soften the welding rod.Preheat both the softened welding rod and the areato be welded for about 5-6 seconds. Gently push thewelding rod through the preheat chamber out of thefront of the nozzle laying if down with pressure on thearea to be welded. DON’T STOP THE MOTIONjust gently work the rod through the preheat chamberand in a slow, fluid motion along the weld until thedesired seam is completed. The welding gun shouldalways be held at approximately a 45 degree anglefrom all surfaces. Typically a triple weld is required andtherefore 3 complete passes should be performed.

Hot Gas Welding (Backwelding)

Hot-gas welding (Backwelding) is a method usedprimarily as a means of joining certain outer compo-nents such as closure joints where one of the othermethods described above are not suitable or possi-ble. 12” Polypropylene as well as any outer PVDFcouplings require the slip fit and backweld method.Performing field pipe repairs may also require back-welding.This method involves the use of a weldingrod filler material matching that of the material beingjoined. The filler material, and immediate surfaces to be joined are heated by means of a hotgas, usually air or nitrogen, and then the filler material is pressed into place along the surfaces tobe joined. With hot gas welding, multiplepassed are usually required. Orion’s speed (hotgas) welding technique, used in slip-fit systems,is shown above. When Backwelding is required, thecontractor should be thoroughly trained prior to makingfield joints.

Hot Gas Welding (Backwelding) Acid Waste Assembly

Page 72: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

72 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Submittal Polypropylene Schedule 40

Pipe:

Flame Retardant Blueline® Schedule 40

Orion’s Blueline® acid waste pipe will be manufactured to the dimensions and tolerances ofASTM F1412 from fire retardant material in 10' lengths. Pipe will be cylindrical and straight. Pipe willbe supplied with factory grooves. The polypropylene material will conform to ASTM D4101.

Non Flame Retardant Brownline® Schedule 40Orion’s Brownline® acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1412 from non-flame retardant material in 10' lengths. Pipe will be cylindrical and straight.Pipe will be factory grooved. The polypropylene material will conform to ASTM D4101.

FittingsOrion Blueline® acid waste fittings will be manufactured to schedule 40 dimensions per ASTM

F1412 and will be made of fire retardant polypropylene. Fitting layouts will conform to ASTM D3311and F1412. The polypropylene material will conform to ASTM D4101.

Joining Methods:

No Hub-Mechanical Joint®Pipe and fittings will be joined using the NO HUB method, Utilizing all PLAIN END fittings joined

with Orion’s No Hub Couplings. All couplings to have a chemical resistance equal to the pipe andfittings. Each No Hub coupling will have an outer band of 300 series stainless steel with 5/16" bolts,nuts and washers plated to meet a 100 hour salt spray per ASTM B117. The No Hub joint will con-form to the requirements of ASTM F1412.

Rionfuse CF® (Clamp-Free) ElectrofusionThe Orion Rionfuse CF System will utilize the SAME plain end fittings as the No Hub system,

but are to be joined using the Rionfuse CF couplings. The Rionfuse machine will be used to pro-duce a hermetically sealed joint. The joints will conform to ASTM 1290, Technique I.

Socket Fusion®All fittings are to be socket end. All joints are to be made with Orion’s heat tools to produce a her-

metically sealed joint. Joints and joining procedures will conform to ASTM 2657, Technique I

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 73: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 73

Polypropylene Schedule 80 Acid Waste Submittal

Polypropylene Schedule 80

Pipe:

Flame Retardant Blueline Schedule 80 ®Orion’s blueline acid waste pipe will be manufactured to the dimensions and tolerances of ASTM

F1412 from fire retardant material in 10' lengths. Pipe will be cylindrical and straight. Pipe will befactory grooved. The polypropylene material will conform to ASTM D4101.

Non Flame Retardant Brownline Schedule 80 ®Orion’s brownline acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1412 from non-flame retardant material in 10' lengths. Pipe will be cylindrical and straight.Pipe will be factory grooved. The polypropylene material will conform to ASTM D4101.

FittingsOrion’s blueline acid waste fittings will be manufactured to schedule 40 dimensions per ASTM

F1412 and will be made of fire retardant polypropylene. Fitting layouts will conform to ASTM D3311and F1412. The polypropylene material will conform to ASTM D4101.

Joining Methods:

No-Hub/Plain End ®Pipe and fittings will be joined using the Riontite No-Hub/Plain End, having a chemical resistance

equal to the pipe and fittings. Each Riontite coupling will have an outer band of 300 series stainlesssteel with 5/16" bolts, nuts and washers plated to meet a 100 hour salt spray per ASTM B117. TheNo-Hub/Plain End will conform to the requirements of ASTM F1412.

Rionfuse CF® (Clamp-Free) ElectrofusionThe Orion Rionfuse CF System will utilize the SAME plain end fittings as the No Hub system,

but are to be joined using the Rionfuse CF couplings. The Rionfuse machine will be used to pro-duce a hermetically sealed joint. The joints will conform to ASTM 1290, Technique I.

Socket Fusion®All fittings are to be socket end. All joints are to be made with Orion’s heat tools to produce a her-

metically sealed joint. Joints and joining procedures will conform to ASTM 2657, Technique I.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 74: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

74 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Submittal Polypropylene BlackLine

Polypropylene Blackline

Pipe:

Non Flame Retardant Blackline Pipe Sch 40 �Orion’s blackline acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1412 from non-flame retardant material in 10' lengths. Pipe will be cylindrical and straight.The polypropylene material will conform to ASTM D4101 and manufactured to Schedule 40 wallthickness.

Non Flame Retardant Blackline Pipe Sch 80 �Orion’s blackline acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1412 from non-flame retardant material in 10' lengths. Pipe will be cylindrical and straight.The polypropylene material will conform to ASTM D4101 and manufactured to Schedule 80 wallthickness.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 75: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 75

PVDF Schedule 40 Acid Waste Submittal

Polyvinylidene Fluoride (PVDF) Schedule 40

Pipe:

PVDF Schedule 40 �Orion’s Super Blue acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1673 from PVDF material in 10' lengths. Pipe will be cylindrical and straight. Pipe will befactory grooved. The PVDF material will conform to ASTM D3222.

Fittings: �Orion’s Super Blue fittings will be manufactured to Schedule 40 dimensions per ASTM F1673

and will be manufactured from PVDF material conforming to ASTM D3222. Fitting layout will con-form to ASTM D3311 and F1673.

Joining Methods:

No-Hub/Plain End �Pipe and fittings will be joined using Orion’s mechanical coupling Each coupling will have an

outer band of 300 series stainless steel with 5/16" bolts nuts and washers plated to meet a 100 hoursalt spray test per ASTM B117. The No-Hub/Plain End will conform to ASTM F1673.

Socket Fusion �All fittings are to be socket end. All joints are to be made with Orion’s heat fusion tool to produce

a hermetically sealed joint. Joints and joining procedures will conform to ASTM 2657, Technique I.

Rionfuse Electrofusion �All Orion Rionfuse fittings to be socket end with stainless steel wire coil inserts. The Rionfuse

machine will be used to produce a hermetically sealed joint. The joints will conform to ASTM 1290,Technique I.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 76: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

76 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Submittal PVDF Schedule 80

Polyvinylidene Fluoride (PVDF) Schedule 80

Pipe:

PVDF Schedule 80 �Orion’s Super Blue acid waste pipe will be manufactured to the dimensions and tolerances of

ASTM F1673 from PVDF material in 10' lengths. Pipe will be cylindrical and straight. Pipe will befactory grooved. The PVDF material will conform to ASTM D3222.

FittingsOrion’s Super Blue fittings will be manufactured to Schedule 40 dimensions per ASTM F1673

and will be manufactured from PVDF material conforming to ASTM D3222. Fitting layout will con-form to ASTM D3311 and F1673.

Joining Methods:

No-Hub/Plain End �Pipe and fittings will be joined using Orion’s mechanical coupling. Each coupling will have an

outer band of 300 series stainless steel with 5/16" bolts nuts and washers plated to meet a 100 hoursalt spray test per ASTM B117. The No-Hub/Plain End will conform to ASTM F1673.

Socket Fusion �All fittings are to be socket end. All joints are to be made with Orion’s heat fusion tool to produce

a hermetically sealed joint. Joints and joining procedures will conform to ASTM 2657, Technique I.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 77: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 77

Underwriters Laboratories, Inc.Northbrook, IL Santa Clara, CA

Melvillve, NY Research Triangle, NCan independent, non profit organization of public safety

CERTIFICATE I

Mfr.’s Ref No. R15537Control No. 1P91

Orion Fittings, Inc., 2850 Fairfax Trafficway, Kansas City, KS 66115 is qualified under the classificationand Follow-up Services of Underwriters Laboratories Inc. to furnish molded plastic, Classified as to SurfaceBurning Characteristics. This manufacturer is therefore authorize to issue this Certificate for the bulk ship-ment of material described below as it’s representation that such material is manufactured in compliance withthe requirements established by Underwrites Laboratories, Inc. for this class of product. This certificate doesnot indicate proper application of installation of the units and does not apply to other material, which may beused at the location specified.

Trade Name: Orion “Super Blue” PVDF Pipe and Fittings

Classification: Underwriters Laboratories, Inc.Classified

Molded PlasticSurface Burning Characteristics

UL 723 (ASTM E-84)

Flame Spread: 5Smoke Developed: 35

UL 723/ASTM E84 Certificate Acid Waste Submittal

Page 78: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

78 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Submittal RIONFUSERElectrofusion Processor

RIONFUSER and RIONFUSER ULTRAFeatures and Benefits

• Automatic internal self-test upon every start-up• Controlled Output Power• Output power variation is +/- 2% (compared to 5 to 7%

with other units)• 4 line, Backlit LCD Display indicates Coil Resistance,

fusion time, ambient temperature, type of coil, power output, error codes

• Controlled Time cycle (2 minute base fusion time)• External Temperature gauge-adjusts fusion time based

on ambient temperature• Internal memory keeps track of date, time, weld #• PC interface capabilities.• Optional memory module is available for in-field

downloading of the Rionfuer’s memory• Readout indicates “successful weld” at end of fusion• Machine will automatically remind the user when it is

time for factory-recalibration (once every 2 years)• The processor will not allow a user to fuse with a power

supply that does not meet the voltage/frequency specs. •The unit will automatically stop the fusion process if

power input drops below minimum requirements. • Highly Shock resistant• Multiple Jointing capabilities (see chart below)• External circuit breaker• Self contained in easy to carry, rugged, suitcase style

enclosure.

• Splash proof during operation.• Wide range of supply voltage (97 to 150 VAC, 47 to 70

Hz, Sine or Square wave)• Operating range of 0°F to 120° F• No Warm up time-turn it on and immediately fuse• No duty cycle.= Increased productivity• Multiple Jointing Capabilities• Remote start button located on output leads• Automatic Dry Cycle-for drying wet joints• Made and serviced in the USA• Fast maintenance turn around times• Light weight - 45 pounds• One Year Warranty• Rionfuser processor is upgradable to Rionfuser Ultra

for large diameter sizes (12” - 18”).

Memory Module allows user to downloadthe processor’s memory on-site and thensend it to Orion for analysis of machinefunction, site conditions and fusion parameters for up to 1000 joints.

Page 79: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 79

Acid Waste Floor Drain Submittal

Floor Drain AWFDSTD

No-Hub/Plain EndComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A

� 2" MJ 4.54

� 3" MJ 4.60

� 4" MJ 4.87

� 6" MJ 3.65

� Funnel

� 1⁄2" Trap Primer FIP

� Sediment Bucket

� Flashing Clamp

� Solid Cover

� Vandal Proofing

� ORION AWFDSTD Corrosion ResistantFloor Drain manufactured from fire retardantpolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to be madefrom fiber-filled polypropylene for strength anddurability.

� ORION AWFDSTD Corrosion ResistantFloor Drain manufactured from PVDF materialconforming to ASTMD 3222. Grate, plug, andcovers are to be made from fiber-filled PVDF forstrength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 80: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

80 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Floor Drain Submittal

Floor Drain AWFDSTD

Socket FusionComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A B

® 2" SF 4.16 .88

® 3" SF 2.94 1.13

® 4" SF 2.94 1.36

® 6" SF 3.50 1.98

® 2" FIP 5.12 .80

® 3" FIP 3.00 1.40

® 4" FIP 2.94 1.50

® 6" FIP 3.50 1.99

® Funnel

® 1⁄2" Trap Primer FIP

® Sediment Bucket

® Flashing Clamp

® Solid Cover

® Vandal Proofing

® ORION AWFDSTD Corrosion ResistantFloor Drain manufactured from Fire RetardantPolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to bemade from fiber-filled polypropylene forstrength and durability.

® ORION AWFDSTD Corrosion ResistantFloor Drain manufactured from PVDF materialconforming to ASTM D3222. Grate, plug, andcovers are to be made from fiber-filled PVDFfor strength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 81: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 81

Acid Waste Floor Drain Submittal

Floor Drain AWFDSO

No-Hub/Plain EndComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A B

® 2" MJ 6.69 3.41

® 3" MJ 7.84 4.56

® 4" MJ 6.97 5.60

® Funnel

® 1⁄2" Trap Primer FIP

® Sediment Bucket

® Flashing Clamp

® Solid Cover

® Vandal Proofing

� ORION AWFDSO Corrosion ResistantFloor Drain manufactured from fire retardantpolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to bemade from fiber-filled polypropylene forstrength and durability.

� ORION AWFDSO Corrosion ResistantFloor Drain manufactured from PVDF materialconforming to ASTM D3222. Grate, plug, andcovers are to be made from fiber-filled PVDFfor strength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 82: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

82 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Floor Drain Submittal

Floor Drain AWFDSO

Socket FusionFloor Drain with side outletComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A B C

® 2" SF .90 6.69 3.41

® 3" SF 1.13 6.05 4.60

® 4" SF 1.50 6.97 5.60

® Funnel

® 1⁄2" Trap Primer FIP

® Sediment Bucket

® Flashing Clamp

® Solid Cover

® Vandal Proofing

® ORION AWFDSO Corrosion ResistantFloor Drain manufactured from Fire RetardantPolypropylene material conforming to ASTMD4101. Grate, plug, and covers are to bemade from fiber-filled polypropylene forstrength and durability.

® ORION AWFDSO Corrosion ResistantFloor Drain manufactured from PVDF materialconforming to ASTM D3222. Grate, plug, andcovers are to be made from fiber-filled PVDFfor strength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 83: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Acid Waste Piping Systems ORION FITTINGS, INC. 83

Acid Waste Floor Drain Submittal

Floor Drain AWFDPT

No-Hub/Plain EndFloor Drain with trapComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A B C

® 2" MJ 5.87 9.33 5.92

® 3" MJ 6.57 12.31 7.71

® 4" MJ 6.04 15.24 9.64

® Funnel

® 1⁄2" Trap Primer FIP

® Sediment Bucket

® Flashing Clamp

® Solid Cover

® Vandal Proofing

® ORION AWFDPT (integral trap) CorrosionResistant Floor Drain manufactured from FireRetardant Polypropylene material conformingto ASTM D4101. Grate, plug, and covers areto be made from fiber-filled polypropylene forstrength and durability.

® ORION AWFDPT (integral trap) CorrosionResistant Floor Drain manufactured fromPVDF material conforming to ASTM D3222.Grate, plug, and covers are to be made fromfiber-filled PVDF for strength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 84: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

84 ORION FITTINGS, INC. Acid Waste Piping Systems

Acid Waste Floor Drain Submittal

Floor Drain AWFDPT

Socket FusionFloor Drain with trapComplete with grate and plugGrate is designed to withstand 10,000 lbs.Check appropriate boxes

Size: A B C D

® 2" SF .90 5.87 5.92 9.33

® 3" SF 1.13 6.52 7.76 12.36

® 4" SF 1.40 6.04 9.64 15.24

® Funnel

® 1⁄2" Trap Primer FIP

® Sediment Bucket

® Flashing Clamp

® Solid Cover

® Vandal Proofing

® ORION AWFDPT (integral trap) CorrosionResistant Floor Drain manufactured from FireRetardant Polypropylene material conformingto ASTM D4101. Grate, plug, and covers areto be made from fiber-filled polypropylene forstrength and durability.

® ORION AWFDPT (integral trap) CorrosionResistant Floor Drain manufactured fromPVDF material conforming to ASTM D3222.Grate, plug, and covers are to be made fromfiber-filled PVDF for strength and durability.

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Page 85: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

Jobame: ____________________________________

JobLocation: _________________________________

Engineer____________________________________

Contractor:___________________________________

Representative:_______________________________

Acid Waste Piping Systems ORION FITTINGS, INC. 85

Model & Size Finish Available

® 3" FCO Square Nickel Bronze;

Brushed Bronze

® 4" FCO Square Nickel Bronze;

Brushed Bronze

® 3" FCO Round Nickel Bronze, PP PVDF

Brushed Bronze

® 4" FCO Round Nickel Bronze; PP PVDF

Brushed Bronze

® ORION FCO corrosion resistant finished floorcleanout. Manufactured from fire retardant polypropy-lene material conforming to ASTM D4101, ferrule sup-plied with countersunk plug and adjustable top withround (square) nickel bronze (brushed bronze) cover,with AWCO (Acid Waste Cleanout) cast in cover.

® ORION FCO corrosion resistant finished floorcleanout. Manufactured from PVDF material conformingto ASTM D3222, ferrule supplied with countersunk plugand adjustable top with round (square) nickel bronze(brushed bronze) cover, with AWCO (Acid WasteCleanout) cast in cover.

Acid Waste Floor Cleanout Submittal

Page 86: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ORION

General Terms & Conditions

Freight AllowanceAll orders are shipped F.O.B. Kansas City,

Kansas with full freight allowed on shipments of$5,000 net price, or more. The following itemsare always F.O.B. Kansas City, Kansas: alltanks, 8"– 10"– 12" and larger pipe and fittings,double containment , sinks and rims and tankaccessories. For shipments to Alaska or Hawaiiand for export freight allowances are as statedabove, freight allowances good only for ship-ment to East, Gulf or West Coast Ports. AllF.O.B. Kansas City, Kansas shipments will beshipped freight collect. When shipping to a jobsite freight will be third party billed.

TermsA 2% cash discount is allowed if payment of

invoice is mailed or delivered within 10 days ofinvoice date. All invoices are due net 30 days,with all Past Due accounts subject to a servicecharge of 11⁄2% per month. Minimum billing orcredit is for $50.00 net. Any order under mini-mum will carry a $10.00 surcharge.

TERMS & CONDITIONSTERMS & CONDITIONS

Order AcceptanceNo catalog, price list, literature or other

material describing Orion products is to be con-strued as an offer to sell same. Orders are sub-ject to acceptance by Orion at our facilities inKansas City, Kansas. Your order, whenshipped by Orion, shall be the complete con-tract between us, subject to, and incorporatingtherein, the terms and conditions herein setforth, and any provisions contained in yourorder that are inconsistent with our terms andconditions shall be inapplicable. Prices and dis-counts contained in any of our catalogs, pricelists or other literature are subject to changewithout notice.

WarrantyOur products are carefully inspected for

manufacturing defects. However, it is notalways possible to detect hidden defects. Ourproducts are warranted only to the extent thatwe will replace them without charge if they areproved to have manufacturing defects withinone year of the date of delivery to the sitewhere they are to be used or installed and pro-vided we have been given an opportunity toinspect any product alleged to be defective andthe installation or use thereof.

86 ORION FITTINGS, INC. Acid Waste Piping Systems

Page 87: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

No warranty is included against anyexpense for removal, reinstallation or otherconsequential damages arising from anydefect. The warranties set out above are theonly warranties made and are expressly in lieuof all other warranties, expressed or implied,including the warranties of merchantability andfitness for a particular purpose.

Rights governed by lawAny agreement for the sale, delivery, or use

of our products shall be construed andenforced in accordance with the laws of theState of Kansas. Any purchaser of our productsexpressly agrees that any legal action or pro-ceeding arising out of or in connection with thistransaction or our products shall be brought inthe appropriate court in Kansas City, Kansas.

Shipping dates or delaysPromises of shipping dates are estimates,

and therefore cannot be guaranteed. Orion willnot be liable for any delay in a delivery.

TaxesAny sales or manufacturers’ taxes existing,

or under future statutes, are to be paid by thebuyer.

Returned goods policy1. Permission to return goods must be

requested in writing. The request mustidentify original shipment of material byinvoice number and date of invoice, and listall goods to be returned.

2. The following items are non-cancelable andnon-returnable, and no credit will be issuedupon their return.

• Non-standard, special order or specialwelded items

• Double Containment

• All tanks, limestone and tank accessories

• All Standard line products

• Sinks and rims

• All PVDF Products

• Expansion joints

• 8"–10"–12"–14”–16”–18” Pipe & Fittings

• All fittings marked with (*) on price sheets.

• All pipe

3. Goods must be returned within one year afterpurchase in order to receive credit.

4. All goods must be returned “Prepaid.” For anygoods purchased on an FFA basis, outgoingfreight charges will be deducted from total creditamount.

5. All goods returned must be in resalablecondition and are subject to our inspection.Items deemed to be unfit for resale will bedisposed of with no credit issued, or returned tothe customer at their expense.

6. All fittings that were purchased with couplings orcoils must be returned with the correct quantityof couplings or coils. No credit will be issued onfittings returned without couplings or coils. Noindividual couplings or coils may be returned.

7. A restocking charge of 25% will be chargedagainst all returned goods, except Whitelinematerials, for which the charge will be 35%.Items requiring special cleaning will be subjectto a 40% re-stock.

8. All goods returned must have Orion’s ReturnAuthorization Number on boxes or cartons, andfreight prepaid. If not, they will be refused.

9. All credit memos issued may be applied tocurrent account balances only or to futurepurchases. No cash refunds will be issued.

Acid Waste Piping Systems ORION FITTINGS, INC. 87

Terms & Conditions Orion Fittings, Inc.

Page 88: Acid Waste Systems - Orion · PDF fileAcid Waste Piping Systems ORION FITTINGS, INC. 5 Quality Orion acid waste and high purity products have been installed in thousands of facilities

ACID WASTE PIPING SYSTEMS

Represented By:

ORION FITTINGS, INC.2850 Fairfax Trafficway

Kansas City, Kansas 66117Phone: 913-342-1653 Fax: 800-777-1653

www.orionfittings.com