*Add supply Voltage: A: 230VAC, B: 24VDC †Supplied with separate power supply
4 Points5 Points6 Points6 Points8 Points12 Points14 Points16 Points22 Points24 Points
Accessories
With Pushbuttons
Red Perspex window 30x30mm c/w LED BlockYellow Perspex window 30x30mm c/w LED BlockGreen Perspex window 30x30mm c/w LED Block
AL-3030-RAL-3030-YAL-3030-G
Small Window no Pushbuttons
Large Window no Pushbuttons
12B2SPO-*10B4SPO-*10B6SPO-*26B0SPO-*
––
20B14SPO-*–
30B22SPO-*–
––––
10B8S00-*––
20B16S00-*–
30B24S00-*
14B0S00-*–––
28B0S00-*312B0S00-*
–416B0S00-*
–†624B0S00-*
Code Description
Monitors potential free input contacts (NO or NC) 4 to 16, for any change of status (Abnormal) & activates one common output relay for audible device with respective flashing LED windows, thus indicating the “Alarm” status. This flashing annunciation window is “Acknowledged” & “Reset” (when returns back to normal) by external push buttons.• Powerful Microprocessor Circuit.• Optically Isolated input Circuit.• Low Power Consumption.• Two Window Sizes, Big & Small.• Built-in system watchdog LED.• Super Bright LEDs.
• Fully integrated construction.• NO/NC selectable input configuration.• AC/DC auxiliary supply.• DIN standard panel cutouts.• Front replaceable windows & Inscriptions.• Moulded enclosures.
SpecificationsAux. Supply:
Input:Output:Rating:Facia Window Size:Flash Rate:
24/48V DC / 110/220V ACPotential Free Contacts (NO or NC Site Configurable)1 NO for Audible Hooter5A, 230V AC ResistiveBig: 60 x 30mm Small: 30 x 30mmFast: 60 Flash/Min. Slow: 30 Flash/Min.
LED:
Interrogation Voltage:Response Time:Power Consumption:Grouping (Trip/Non Trip):
Colour Red (Amber/Green on request)12V DC
25m.sec. ±10m.sec1.5W/WindowOptional
12B2SPO 10B4SPO 10B6SPO 26B0SPO 10B8S00 20B16S00 28B0S00 312B0S00
14B0S00 416B0S00
Printing of Front Replaceable Windows
30 x 30mm transparent film60 x 30mm transparent film
AL-30AL-60
Code Description
• Black letters on transparent film to be sandwiched between front & rear difusers
●
●
●
Cutout Size
68x138 68x138 68x138138x138
138x138
210x138
Cutout Size
68x138
138x138
210x138
Cutout Size
68x138
138x138210x138
282x138
2x(210x138)
ALARM ANNUNCIATORS
Red Perspex window 60x30mm c/w LED BlockYellow Perspex window 60x30mm c/w LED BlockGreen Perspex window 60x30mm c/w LED Block
AL-6030-RAL-6030-YAL-6030-G
Code Description●
●
●
Description CodeSupply Size8-Channel Annunciator8-Channel Annunciator10-Channel Annunciator
M4100-12M4100-22M1000-24-00C
12VDC/AC ±30%24VDC/AC ±30%12-24VDC
96x9696x96144x144
8 & 10 Channel Alarm Annunciator• Input contact type NO/NC and delays
0-15 secs are selectable individually on all channels.
• Two common output relays for siren and alarm with voltage free contacts.
• Legend can be typewritten on the label easily accessible behind front plate.
• Two integrated push buttons for siren reset/lamp test and alarm accept.
• Remote individual selectable blocking with adjustable unblocking delay 0-15 secs.
• Plug-in terminal block for easy service.• DC or AC supply voltage.
Specifications for M4100• Consumption: 0.15A• Temp Range: -20˚ to +70˚C• Minimum input delay: 50ms
Accessories for M4100Front cover with handle IP54 M0846-00 Front cover with key IP54 M0846-01
Specifications for M1000
• Output relay : Max. 220V AC/2A• Output : Max. 150mA per channel• LED flash frequency : Slow Flashing Light 0.8Hz ±10% Quick Flashing Light 8Hz ±10%• Programming : Switches on rear of unit• Reset/Lamp Test : Via Pushbuttons• Power Consumption : 180mA
M4100 M1000
DPM 177
INST
RU
MEN
TS
M90 extended family of PLCs extends to 158 I/0, GSM and MODbus communication, with embedded graphic operator panel. PLC & HMI programmed with one programme! All models supplied with software, instruction manual, cable & connectors.
Expansion Modules
Accessories
For power supplies, see page 69.
OPLC-GSM-K1M90-19-R4V200-19-ET1
GSM modem, magnet antenna, cables and adaptorsRS232 to RS422/485 converterEthernet module for PLC V230 & V260 only
Communication OptionsEX-A1IO-DI8-TO8IO-AI4-AO2IO-DI8-RO4IO-DI16IO-TO16IO-RO8EX90-DI18-RO8IO-PT4
Expansion Adaptor8 Digital Inputs, 8 Transistor Outputs4 Analog Inputs, 2 Analog Outputs8 Digital Inputs, 4 Relay Outputs16 Digital Inputs16 Transistor Outputs8 Relay Outputs8 Digital Inputs, 8 Relay Outputs4 PT100 Inputs, -42 to 112°C
M90-R1
M90-R1
-CAN
M90-R2
-CAN
M90-T1
M90-TA
2-CAN
V120
-12-R1
V120
-12-R2
C
V120
-12-UN
2
V230
-13-B2
1
V260
-16-B2
1
1 line x 16 characters80
15
2048 words
256256
–64–
12µsec
1 portRS232/485 converter supplied
– 1 port 1 port – –
Up to 6 phone numbers, up to 1k of user defined messages
8 PNP 10 PNP2 (16 bit)
12 24 – 25
– 6 – – 11 8 – 1 (0-10V) – 1 (1.5kHz) –
Up to 64 extra I/O via 8 expanders
24VDC96 x 96
8 lines x 22 characters 128 x 64p255
16
16k words
10241024256
128 (32 bit)64 (32 bit unsigned)
0.8µsec
2 ports1 port
– 1 port –Master/slave protocol
Up to 8 phone numbers
7 PNP/NPN 8 PNP/NPN 3 (32 bit) 2 (32 bit) 12 22 (2 below)
26
6 – – 10
– – 2 (2kHz)
12/24VDC96 x 96
128 x 64p 240 x 64p100
24 33
16k words
20481600256192
64 (32 bit unsigned)0.8µsec
2 ports1 port1 port
Master/slave protocolUp to 8 phone numbers
16 PNP/NPN2 (32 bit)
33
–10
4 PNP/NPN–
2 (50kHz) NPN
12/24VDC218 x 184 260 x 184
Notes: 1) High speed counter/shaft encoder/frequency measurer of normal digital inputs, 10kHz max. Can be used as normal digital input. 2)10 bit analog input: 0-5V, 0-10V, 0-20mA, 4-20mA. 3) 10 bit analog input: 0-10V, 0-1mA, 4-20mA,4-20mA. 4) 10 bit analog input: 0-5V, 0-10V. 5) 10 bit analog input: 0-10V. 6) 14 bit universal input for thermocouple, PT100, 0-10V, 0-20mA, 4-20mA.
Up to 128 I/O extra via 8 expanders
• RS232/485 Up to 64 mixed M90 family units
• CANbus • MODBUS • GSM/SMS control • Remote access with any
phone-line modem
DisplayResolution (Pixels)HMI displayKeyboardNo. of keysProgrammePLC sizeReal time clockCoilsRegisters/integers32 bit integersTimersDouble wordExecution timeCommunicationRS232RS485CANbusMODBUSGSMI/OsDigital inputsHigh speed inputAnalog inputThermocouple/PT100Relay outputspnp outputsAnalog outputsHighspeed outputI/O expansionGeneralPower supplySize mm
Real-time clock functions (date and time) with 7 year battery backup – all models
IP65 when panel mounted
One Windows-based program for both PLC & HMI
Note: when using expansion modules expansion adaptor must be installed
DPM
MICRO PLCs
INST
RU
MEN
TS
178
The Lm Micro Series PLC is comprised of various modules. The basic functional configuration requires a CPU module working as a basic unit, in comple-ment with optional expansion modules such as communication modules, digital I/0 modules and analogue I/0 modules
Expansion Modules
AccessoriesLS3601LA3801-COM-300LA3810HT6100HD2100
LM PLC & HMI Programming Software CDLM Communication Cable - RS-232 Cable (2m)LM Expansion Module (500mm length)HMI USB Programming cableRS-232 Serial programming cable
Communication Options
LM MICRO SERIES PLCs
LM3210-EDILM3211-EDIALM3220-EDOTLM3222-EDORLM3221-EDOTLM3223-EDORLM3310-EAILM3320-EAOLM3401LM3403
8 Digital 24VDC input module8 Digital 230VAC input module8 Digital 24VDC solid state output module8 Digital 230VAC /24VDC relay output module16 Digital 24VDC solid state output module16 Digital 230VAC/24VDC relay output module4 Channel Analog input module4 Channel Analog output moduleProfibus DP slave interface moduleEthernet interface module
LM31
04
LM31
05
LM31
06
LM31
07E
LM31
09
LM32
30-ED
MTLM
3231
-EDMR
LM33
30-EA
M
HT66
00C
HT68
00T
24VDC 240VAC 24VDC 240VAC 240VAC125(L) x 90(W) x 70(H)mm
Unlimited number of counters, 15 bits counting rangeUnlimited number of timers, 1ms to 49days
0.37µs per instructionReal time clock function, 10 years back-up
60 000 words
1 1 1 1 1 – – – – 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
5 5 11 9 21 3 3 3 3 3 – – – 2 – – 6 – 8 16 6 – 10 – 1 – – – 1 –1Point,20kHz – 2Points,20kHz – – 2 2 4 4 7
Expansion Modules21-28VDC
192 x 138mm 224 x 161mm
320 x 240 640 x 48010 000hrs
200mHz RISC
128k WordsCommunication
RS232RS485ModbusG-Mode
I/OsDigital Inputs
Digital High Speed InputsAnalog Input
Relay OutputsPNP Outputs
Analog OutputPulse Output
Max Expansion Module
GeneralHMI Display
50(L) x 90(W) x 70(H)mm
12bitA/D10 000 000 Open/ Close
<10ms <10ms <10ms
65535words
– – –– – –– – –– – –
4 4 –– – –– – 4– 4 –4 – –– – –– – –– – –
CPU ModulesPower Supply
SizeProgramme
ResolutionTimers/ LifespanExcecution timeReal Time Clock
PLC Program Size
Code Description
Catalogues & ManualsLD3000LD3001LD3002HT6101LM3101HMI101
LM Micro Series PLC - Hardware ManualLM Micro Series PLC - Software ManualLM Micro Series PLC - Instruction ManualHMI User GuideComplete software & infoComplete software & info
Connections
DPM
Programming Languages• Instruction List (IL) • Function Block Diagram (FBD)• Sequence Function Chart (SFC) • Structual Text (ST)• Ladder Diagram (LD) • Continuous Function Chart (CFC)
Connection to expansion modulesWiring terminal for output + input power supplyWiring terminal for input + output power supplyRS-232/RS-485 communica-tion portRUN/STOP operation switch + analogue presetsI/O channels status indicatorPLC status indicator - Run, Stop, Com, ErrorHeat radiatorDIN Rail fastenerHole for backplane or wall mounting
12
3
4
A
BC
DEF
179
INST
RU
MEN
TS
Rotating Disc kWh Meters 0142 Authorisation No. 0102402
1-Phase 230V Range 3-Phase 380V+N Range
6 Digit register Metal Base and Polycarbonate coverLower bearing is magnetic suspension type
HX12D-40 10-40AHX12D-60 15-60AHX12D-80 20-80ASize (mm): 160H x 122W x 126D
HX34D-80 20-80AHX34D-100 30-100AHX34C CT-5ASize (mm): 260H x 170W x 135D
HX12D-40/60 HX34
DDS223-63 DDS722-100 DTS722-60/100
Mechanical Counter kWh Meters
3-Phase 400V+N Range Size Pulse/kWDTS722-60DTS722-100
Digital kWh Meters
3-Phase 400V + N
DDSF223-30DDSF223-63DDSF722-60
1-Phase 230V
DSS722-5DSS722-60DSS722-1001m=17.5mm Wide
• Pulsed output 3200 Imp/kWh • Class 1
DDSF722-60 DSS722-5/ 60/ 100
Range Size Pulse/kW
3-Phase 400V+N
5-30A 1m 20005-63A 2m 20005-100A 3m 800
DDS223-30 DDS223-63 DDS722-100
1-Phase 230V
Range Size Pulse/kW5-60A 6m 3205-100A 6m 160
Range Size Pulse/kW5-30A 1m 2000 5-63A 2m 2000 5-60A 3m 1600
Range Size Pulse/kW1.5-5A (CT) 6m 16005-60A 6m 3205-100A 6m 160
Pre-payment kWh Meters
Code DescriptionDDSY238-60DTSY238-60
DTSY238-80
Single Phase3-Phase4 wire 400V+N3-Phase meter.4wire 400V+N
• Power failure memory • Direction of power indication• Anti-theft function • Coded card for fraud protection• Software requires Windows XP© or Windows 7©
Accessories
Code DescriptionDDSY-CDDSY-P
Amps15-60A15-60A
20-80ADDSY-C
OutputPulses/kW1600200
100
DDSY-P
Pre-payment CardCard readers. c/w program software
Code Size Accuracy DisplayECR-3-72ECR-3-96
72 x 7296 x 96
1% ±1 digit1% ±1 digit
4-digit 14.2mm high4-digit 14.2mm high
CT-Ratio.../5A.../5A
Range0.00-0.990.00-0.99
Digital Power Factor MeterOperating
Voltage230VAC ±10%230VAC ±10%
Non-flammable enclosureFlush mounting with rear terminals
DPM
PRE-PAYMENT kWh METERS
POWER FACTOR METER
kWh METERS
DDSF223-30 DDSF223-63DDS223-30
INST
RU
MEN
TS
180
Supply Voltage UnCurrent, (I max)Operating CurrentFrequencyOperating VoltagePower ConsumptionPrecision accuracy classPulse transmissionRecorded harmonicsSize: 1M = (17.5mm)Digits
230VAC5(25)A
0.02 to 25A50/60Hz
195 to 253V0.5VA
Class 1Type SO
Until 7kHz1m5+1
230VAC5(32)A
0.02 to 32A50/60Hz
195 to 253V0.5VA
Class 1Type SO
Until 7kHz2m5+1
230VAC10(63)A
0.04 to 65A50/60Hz
195 to 253V0.5VA
Class 1Type SO
Until 7kHz2m5+1
MODULAR ENERGY METER (kWh)
Code CONTAX 2511 CONTAX 3221
• DIN Rail Mount• Operating Temp:
-20 to 50°C
CONTAX 6521
CodeW, Wh orVA, Vah or ELF3234VAR, VARh orPF
W, Wh, PF orVA, Vah,PF or ELF3234-3VAR, VARh, PF
V, A, F ELF3259
• Inputs (V), 110 or 400VAC Range: 80-500V 3 Phase 4 Wire
• Input (I) 1A or 5A programmable• Supply Volts: 80-270VAC @ 3VA
Accuracy: 2% for VARh All others: 1%
• Phase wise & total RMS for power, total for Energy Meters
• 10 year back-up of integrated data• VA function selectable 3D or Arithmetic• V shows all Line-Line, Line-Neutral,
Individual & Average Voltages• Size: 96 x 48 x 40(D)mm
1C15WRPkWh and kVARh3 Phase 400V + N
Indication (Active and Reactive Power)
• 7 Digit Electro-mechanical display• Accuracy: 2% (kWh)
3% (kVARh)
230VAC40 (80)A0.08-80A50/60Hz230VAC
<2VAClass1
1000lmp/ kwh–
1m6+1
ES-80L
PM-KW10-99kW Indicator
• c/w 16A Plug & Socket• Ideal to check your kW
usage from generator etc.
c/w 80A CT
kWh METERS
230VAC5 (32)A
0.02-32A50/60Hz230VAC
<2VAClass1
1000lmp/ kwh–
1m6+1
ES-32L
c/w tamper-proof terminal seal
1 x kWh 1C15WP3 Phase 400V + N
kWh MeterC/T Ratio selectable by DIP SwitchSelectable Primary CT Current:
5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300, 400, 500, 600, 750, 800, 1000, 1200, 1250, 1500,
1600, 2000, 2500, 3000, 4000, 5000, 6000• 7 Digit Electro-mechanical display
• Accuracy: 2%• Pulsed Output
2 x kWh 1C15WP2
DPM
RIMD.W15230VACCT.../5A60, 100, 150, 250, 400, 600, 1000/5A50/60Hz195 to 253V4VA2m3
Supply Voltage UnCurrent, (I max)Operating Current
FrequencyOperating VoltagePower ConsumptionSize: 1M = (17.5mm)Digits
CodeDigital Power kWh MeterkWh Indicator
181
INST
RU
MEN
TS
Zaptronix kWh Meters
Energy & Maximum Demand• kWh, kVAh, kVArh • kW and kVA • Block & Moving window
ZAP03BE-MD only• Data & Event logging • RS232 • Pulse output• Time of use
Features:Measurement parameters• Watt, VAr, VA (Import/Export & per phase)• Volt, Amp, Power Factor, Frequency
kWh Meter + Maximum Demand
Code System V Range Amps Accuracy
ZAP1CSZAP1CS-R
1ph, 2-wire, 230V1ph, 2-wire, 230V with RS485 Serial Port
Type
BS
BS
184-275V
184-275V
100A
100A
10-100, Class 1
10-100, Class 1
ZAP03BE-MD* 3ph, 4-wire, 230/400V 184-275V (L-N) 5A 1-5/6, Class 1
ZAP03BS / ZAP03BE-MD / ZAP03LM
ZAP03DS
AccessoriesZAP-EDAT • EDAT+g for GSM-GPRS AMR at multi meter (up to 128) Installations ZAP3AM, ZAPICS, ZAP03LM • EDAT+e for Internet AMR at multi meter (up to 128) installations ZAP1CS, ZAP3AMZAP-SOFT Remlt! Lite Programming Software CD. – download for free. Can be downloaded from
www.zaptronix.co.za/downloads, This is for ZAP03DS , ZAP03BE, ZAP03BS ZAP-OPTO Optocoupler RS232 for BS type housingZAP-OPTO/USB Optocoupler USB for BS type housing*ZAP-PRO Factory programming for ZAP kWh meters (free service)ZAP-MPS (MPS) Meter reading & configuration software. Free download from www.zaptronix.co.za This is for ZAP03AM, ZAP1CS
kWh METERS
Single Phase High Load (100A) Direct Connect, Class 1 Accuracy Billing Meter
ZAP-OPTO
BS
*Note: All 3-phase meters must be programmed before use
Features:• Billing meter for active (kWh) import & export energy • 3 Phase , CT and VT connected Meter• Low cost, no maintenance required • Large , Multi function LC -Display• Easy Meter Communication via Infrared flag port• Engineering software included/ available for download at no charge
Mounting
DIN Rail
Din Rail
ZAP03DS*ZAP03BS*
3Ph, 4 wire, 230/4003Ph, 4 wire, 230/400
DINBS
184-275V (L-N)184-275V (L-N)
5A5A
1-5/6, Class 11-5/6, Class 1
Three Phase Active Energy Meter (CT-Connected)DIN RailBase Mount
Base Mount
Features:As per ZAP03BE-MD plus: I/O; 2 x I/P MD synch, E01, water or gas pulse (programmable); 4 x O/P load shedding, rated for 20mA @ 30VDC.Additional Registers:• Target demand • Interlock timer • Load priority setting• Percentage Hysteresis • Override • Load switching frequency
kWh Meter + Maximum Demand + Load Management (Load Shedding)
ZAP03LM 3ph, 4-wire, 230/400V (L-N) 5A 1-5/6, Class 1BS Base Mount
ZAP3AM5/PZAP3AM100ZAP3AM160
3Ph, 4 wire, 230/4003Ph, 4 wire, 230/4003Ph, 4 wire, 230/400
–––
230V/400V230V/400V230V/400V
5A100A160A
1-5/6, Class 110-100, Class 110-160, Class 1
PI-Range Profiling - Energy Demand Logging Multi-tariff Meter - IEC 62053-21Base MountBase MountBase Mount
Features:• Billing meter for active (Wh) and reactive (VArh) energy demand (VA)• Flexible multi-tariff (TOU) billing meter with auto registration• Profile logging of total energy and average energy demand
ZAP3AM5 230VZAP3AM5 110V
3Ph, 4 wire, 230/4003Ph, 3 wire, 110V (P-P)
––
230V/400V110V-480V
5A5A
1-5/6, Class 11-5/6, Class 1
Lambda-Range Logging - Energy Demand Logging Multi-tariff Meter - IEC 62053-21Base MountBase Mount
Features:• 4 Quadrant, billing meter for active (Wh) and reactive (VArh) energy demand (VA)• Data storage of last 16 months energy and maximum demand for 4 tariffs• Load profile with integration period 1, 5, 30, 60min• Event registration of power outages, per phase voltage loss, under/ over voltage• Full multi-tariff (TOU) billing meter with auto registration• Extensive 6 channel logging from 32 readings and event recording• Remote automated meter data acquisition via IP or GSM-GPRS/SMS
ZAP1CSZAP1CS-R
ZAP3AM
*Add 110V for 3 phase system 3PH, 3 Wire, 88-132V (P-P)
*Add 110V for 3 phase system 3PH, 3 Wire, 88-132V (P-P)
• Remote automated meter reading ready (ZAP1CS-R)
• Remote automated meter reading ready with ZAP-EDAT
DPM
INST
RU
MEN
TS
182
White (or green/ Yellow) Wire to Phase
Blue wire to Blue phase
Black Wire to Neutral
Red Wire to Geyser
Ditto for other controllers
White (or Brown) wire to Seconary side of Geyser C/B (or Isolator)
Red (or Brown)Wire to Red Phase
DPM
ENERGY SAVING CONTROLLER
Code
Monitor your own electricity and save power and money!
AML-1208 • 1 x Current sensor• 1 x Sender unit• 1 x Display unit
With the standard electricity In-Home-Display unit, you can clip the current sensor around the electricity meter's live feed supply such that it measures the total electrical power entering your home or office. Power consumption will be recorded and transmitted to the display unit wirelessly.The following features are provided also: • Dual battery system is used to extend operation period and to prevent data lost during battery changing • Indicate existing cost alert level by Tri-color LED • Display temperature and current time • Clock alarm and cost alert level setting • Monitor up to 8 sensors • Support >30m RF transmission• 4 x Batteries
• 1 x User Manual• 1 x Desk Stand
This product is a semi-portable communication product used in the household market. You can view the instant electricity consumption, cost-up-to-current-hour and records (eg. hourly, daily, weekly, and monthly) as well as estimated CO² emission produced. Transmitting frequency 433mHz with proprietary communication coding for different market segments.
(1-Phase) Monitoring System
Geyser Controller with Embedded Microprocessor
WIRELESS POWER DISPLAY UNIT
Geysers are the largest user of electricity in most households using up to 60%. GC-100 geyser controller will save 40%-60% of geyser usage.
Code GC-100Features • Immediate saving from first monthly bill.
• Ensures geyser is off during peak periods• Back-up battery to retain memory• Override switch geyser off and on• 8 Pre-programmable time periods
Technical Info• Input Voltage: 220/ 240VAC 50Hz• Mounting: Din Rail• Memory: 120 day battery• Current Sensor: 20Amps• Relay output 20A
Passive Power Factor CorrectionPower Factor Correction (PFC) is a technique of counteracting the undesirable effects of electric loads that create a power factor less than one. This range of passive (PFC) units can save 10%-20% of energy consumpion.
Code DescriptionES15ES100ES300ES3001ES3002
Single-Phase (1000kwh) 16A SA plug-in typeSingle Phase (2000kwh)Three-Phase (6200Kwh)Three-Phase (10 000Kwh)Three-Phase (15 000Kwh)
Technical InfoSingle-Phase voltage: 220-240VAC 50HzThree-Phase voltage: 380-420VACOperating temperature: 60˚C (max.)
Features Prolongs life of appliancesStabilise electrical currentAvailable in single and three-phaseSuitable for home, shops, offices, restaurants, etc.
Combination Geyser/ Power Factor Protection & Surge ProtectionCombination units consist of both geyser controller and passive power factor (energy saving). These are parallel connection types, for single and three phase units, some available fitted with surge protection.
Code DescriptionES100-GCES100-GC-SSES100-2GC-SSES300-GCES300-GC-SSES300-2GC-SS
Single phase power + Geyser controllerSingle phase power + Geyser + Surge protectionSingle phase power + 2 x Geyser + Surge protectionThree phase power + Geyser controllerThree phase power + Geyser + Surge protection (3ph+N)Three phase power + 2 x Geyser + Surge protection (3ph+N)
Technical InfoSingle-Phase voltage: 220-240VAC 50HzThree-Phase voltage: 380-420VACSurge Protection: 65kA
MS15
ES100
ES300
Dimensions 95 x 56 x 56125 x 85 x 60190 x 140 x 70D240 x 190 x 90D240 x 190 x 90D
Dimensions170 x 200 x 85mm170 x 200 x 85mm170 x 200 x 85mm210 x 215 x 100mm210 x 215 x 100mm210 x 215 x 100mm
(3 Phase) Monitoring System*Add 2 x Current Sensor (AML-CS) + AML-1208CodeAML-CS
Kit Description
DescriptionCurrent Sensor
The three-phase energy saver can be wired either at the DB or the incoming Eskom box.Note: As long as the black is connected to neutral, it does not matter which of the other wires connect to which phase.
Eco-F
rien
dly
183
INST
RU
MEN
TS
Type CodeTotem Pole Output (HTL)NPN N/O Output (TTL)Line Driver Output (TTL)Pulses/Revolution
Supply VoltsE40S6-*-3-1E40S6-*-3-2E40S6-*-6-L
12-24VDC12-24VDC5VDC
*Add to code: *100, 360, 500, 1000,1024
Code Supply VoltsE50S8-*-3-1E50S8-*-3-2E50S8-*-6-L
12-24VDC12-24VDC5VDC
*Add to code: *50, 100, 200, 250, 360, 1000, 1024, 1800, 2500, 3600
40mmØ, Shaft type encoder(Incremental Type)
50mmØ, Shaft type encoder(Incremental Type)
Shaft
Totem Pole OutputNPN Open OutputLine Driver Output
Max. Response Freq.
Specifications 6mm 8mm
Low Load current: Max. 30mA, Residual voltage: Max. 0.4VHigh Load current: Max. 10mA, Output Voltage: Min. 1.5V
Load Voltage: Max. 30V, Load current: Max. 30mA, Residual Voltage: Max. 0.4VLow Load current: Max. 20mA, Residual Voltage: Max. 0.5VHigh Load current: Max. -20mA, Output Voltage: Min. 2.5V
180kHz
Code E4DC-6/6Code E5DC-8/8
Coupling
Code E5DC-10/10
Manual Start/StopFuel and Start solenoid
Common AlarmLow oil Pressure
High Engine Temp.Auxiliary Shutdown
Charge Fail
None
None
NoneNone
First Up Fault*Low oil Pressure
*High Engine Temp.*Charge fail warning*Auxiliary shutdown
68 x 68None
ApplicationRelay outputs
Digital inputs
Analog inputs
Config. Method Event logging*Comms. Port RS232 or RS485
Operator Display
Other Feautres
Panel CutoutCANbus
Code DSE501K-1
GENSET CONTROLLERS
AMFFuel on, Crank
2 x Configurable
Low oil PressureHigh Engine Temp.Auxiliary Shutdown
+2 ConfigurableNone
Via front face
NoneNone
Warning/Shutdown &active inputs are
signalled by LEDs, load transfer (contactor control) have a mimic
LED display
149 x 109None
704AMF
Fuel, Crank, Mains & Alt Contactor
2 x ConfigurableLow oil Pressure
High Engine Temp.Auxiliary Shutdown
+2 ConfigurableNone
Via front face
NoneNone
Hour counter + warning/shutdown & active
inputs are signalled by LED's Load transfer,
(contactor control) have a mimic LED display
154 x 98None
4120AMF
Fuel, Crank, Mains & Alt Contactor
2 x ConfigurableLow Oil Pressure, High Engine Temp,
Emergency Stop, Remote Start (3 attempt) or Mains Stimulation,
Charge Fail (D+) 2 Configurable2 Inputs. Coolant temp. & oil pressure with the option of
configuring these as digital inputsFront face or PC via interface
type P810NoneNone
Backlit LCD scrolling Mains - Alternator voltage. Load Current,
Oil Pressure, Engine Temperature, DC Volts, Hours Run, RPM and
Hz, Alternator or Mains info, Common Alarm and Scroll Button.
Mimic LEDs, Mode Selection
182 x 137None
DSE720AMF
Standard Gen Controller Outputs
+ 4 x fully ConfigurableStandard Gen Controller
Inputs+ 8 fully Configurable
4 including pressure, temperature and fuel volume
Limited front face, Fully via USB programming port250 most recent events
Type of events recorded can be selected. Fitted with both RS232 and RS485, but only one can be used at a time
Multi Menu Access via front panel: Status, Engine,
Generator, Mains, Alarms, Event log, Serial Port
• Modbus RTU • IP65 gasket • USB connectivity & SCADA• Engine exercise Schedular • Dummy load control plus
load shedding up to 5 stages220 x 160CANbus
DSE7320
All controllers are suitable for 12 or 24V DC systems.*For remote real time diagnostics and telemetry, including SMS communications. PSTN or GSM modem not included.
Code P810 INTERFACEUSB Interface Module c/w cables and software for programming Model 720
ROTARY ENCODER
DPM
INST
RU
MEN
TS
184
72 x 72YY2NN YNNN
L1/NL-L-N
NNNNNN N
LEDYYNNYY
96 x 96YY21N YYNN
L1/NL-L-N
NNYYYN N
LEDYYNNYY
144 x 204 x 37 YY21N YYNN
L1/NL-L-N
NNYYYN N
LEDYYNNYY
144 x 204 x 37 YY64Y YYYY
L-L-NL-L-N
YYYYYY
Last 50 eventsLCD
YYYYYY
144 x 204 x 37 YY64N YYYY
L-L-NL-L-N
YYYYYY
Last 32 eventsLED
YYYYYY
Size (mm)Automatic engine start/stop and load transferManual, Automatic and Test Mode controlUser configurable inputsUser configurable outputsOptional expansion board with user configurable 8 I/O EXOM-210.FL.EXRSpeed sensing from alternator voltageSpeed sensing from magnetic pickup3 resistive sender inputs (oil, fuel, temp.)Load current measurementGenerator Volts measurementMains Volts measurementEarth current measurementExercise at programmed time intervalsRS-232, Modbus ASCII Serial communicationAvailable for Remote using by PC softwareStandard modem communicationGenerator Power measuring by kVA, kW, kVAh, kWh, kVAr, kWrhEvent logsDisplayMains contactor outputsGenerator contactor outputsProgrammable weekly working permit calendarMaintenance warning (working hour or elapsed month)Fully ProgrammableSimple push button controlled operation
Model EAOM-19 EAOM-09 EAOM-09F EAOM -210FLS EAOM-210FDS
YY
Frequency Measurement
NYN21YN YYN
LED72 x 72
YY
Generator Voltage/ Power Measurement
3 PhaseYN32YY YYY
LED96 x 96
YY
Generator Voltage/ Power Measurement
1 PhaseYY32YY YYY
LED96 x 96
Automatic engine Start/StopAutomatic Shutdown on fault conditionAlternator voltage and fre-quency measurementLoad current measurementRemote Start/Stop input3 resistive sender unitsUser configurable inputsUser configurable outputsSpeed sensing off AlternatorSpeed sensing off magnetic PickupRS-232 Serial CommsRemote use from PCStandard Modem CommsDisplaySize (mm)
Model EAOM-36 EAOM-7 EAOM-71
144 x 204 x 37 YY64N YYYY
L-L-NL-L-N
YYYYYY
Last 32 eventsLCD
YYYYYY
MESSENGER
EAOM-19 EAOM-9 EAOM-9F EAOM-210FLS EAOM-2FDS MESSENGERwith GSM
ATS-10 EAOM-3ControlsGenerator remote startLoad transfer to mainsMains and generator contactorMonitors3 Phase mains voltageAlternator voltageProgram parameters
Size: 72 x 72mm
ControlsFuel and stop solenoidStarter motorManual generator start/ stopPreheat (Glow Plug)MonitorsEngine running timeError IndicationFail MonitoringLow oil pressureHigh temperatureOver speed failureCharging fail
Size: 72 x 72mm
Automatic Transfer Switch
Manual Key Start Controller
DPM
GENSET CONTROLLERS 8-32 VDC
185
INST
RU
MEN
TS
• Climatic category: 25/85/21.• Standard tolerance: ±5%; -2+8%.• Rated frequency: 50 – 60Hz.• Voltage: 1.1 Un at 50Hz.• Dissipation factor at 20°C, V = Un, 50Hz: ≤15:10-4
Specifications• Dielectric material: Metalised polypropylene, low losses non inductive winding.• Case and cover: self-extinguishing thermoplastic resin.• Lead: 2 x 0.75mm2. PVC 90°C.• Reference standards: CEI 33-3; VDE 560-8; ASE 1029; VDE EN60252.
Code Capacitance(µF)
SizeØ x H mm
CA-2MFCA-2.5MFCA-3MFCA-3.5MFCA-4MFCA-4.5MFCA-5MFCA-6MFCA-6.3MFCA-7MFCA-7.5MFCA-8MFCA-9MFCA-10MFCA-11MFCA-12MF
22.533.544.5566.377.589101112
25 x 5325 x 5325 x 5325 x 5325 x 5325 x 5325 x 6925 x 6925 x 6925 x 6930 x 7330 x 7330 x 7330 x 7330 x 7335 x 73
Code Capacitance(µF)
SizeØ x H mm
CA-13MFCA-13.5MFCA-14MFCA-15MFCA-16MFCA-17.5MFCA-18MFCA-20MFCA-25MFCA-30MFCA-32MFCA-35MFCA-40MFCA-45MFCA-50MFCA-55MFCA-60MF
1313.514151617.51820253032354045505560
35 x 7335 x 7335 x 7335 x 7335 x 7335 x 7335 x 7335 x 9635 x 9640 x 9540 x 9540 x 9550 x 10050 x 10050 x 10050 x 10050 x 100
MOTOR STARTING & LIGHTING CAPACITORS
Code Capacitance(µF)
SizeØ x H mm Code Capacitance
(µF)
Motor Run Capacitors – 480VAC Motor Start Capacitors – 275VAC
CAR-1.5MFCAR-2MFCAR-3MFCAR-4MFCAR-5MFCAR-6MFCAR-8MFCAR-10MFCAR-12MFCAR-14MFCAR-16MFCAR-18MFCAR-20MFCAR-25MFCAR-30MFCAR-40MFCAR-50MF
1.523456810121416182025304050
25 x 5525 x 5530 x 6332 x 7332 x 7332 x 7332 x 7332 x 7335 x 7535 x 7535 x 7535 x 9835 x 9835 x 9840 x 9450 x 10050 x 100
CAS-30MFCAS-50MFCAS-100MFCAS-125MFCAS-130MFCAS-160MFCAS-300MFCAS-328MF
30 - 3653 - 6488 - 106124 - 149130 - 156145 - 174270 - 324328 - 454
SizeØ x H mm50 x 8550 x 8550 x 8550 x 8550 x 8550 x 8550 x 11060 x 110
Supplied with 150mm flying leads and M8 mounting stud
Lighting Capacitors – 250VAC
With mounting stud M8
T
CA
PAC
ITO
RS
& P
FC
186
R0440-050R0440-075R0440-100R0440-125R0440-150R0440-200R0440-250R0440-300R0440-350R0440-400R0440-450R0440-500R0440-600R0440-700R0440-800
440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V
57.51012.51520253035404550607080
6.5A9.7A13A16A20A26A33A40A46A52A58A66A79A92A105A
300 x 115 x 115300 x 115 x 115300 x 115 x 115300 x 115 x 115300 x 115 x 115425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 320 x 150425 x 320 x 150425 x 320 x 150
Code Rated Voltage 440V
468.510.51317222629353844526070
400VCurrentper Phase
DimensionsH x A x P(mm)
Code Ø x Hmm
C440-010C440-015C440-020C440-025C440-030C440-040C440-050C440-075C440-100C440-125C440-150C440-200C440-250C440-300C440-350C440-400C440-500
70 x 21570 x 21570 x 21570 x 21570 x 21570 x 21570 x 21585 x 215100 x 215100 x 215100 x 300120 x 300120 x 300136 x 300136 x 300136 x 300136 x 300
Currentper Phase1.3A1.9A2.5A3.2A3.8A5.0A6.3A9.7A13A17A20A26A33A39A46A58A66A
440VkVAr at
11.522.53457.51012.515202530354050
400V0.81.21.522.53468.510.513172226293645
Ideal for use with harmonic filters• Terminals – clamp type • Mounting via stud • Overpressure disconnection • Discharge resistors fittedManufactured to EN60831-1/2
Rated Voltage440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V
Cylindrical 3 phase power factor capacitors
Technical CharacteristicsCapacitance tolerance: -5 +10%Frequency: 50Hz (60Hz on request)Temperature Range: -40°c + 55°cDielectric Losses: ≤ 0.5 W/kVArMaximum over voltage: 1.11 x UnMaximum over current: 1.5 x InFuse ratings to be 1.5 to 1.8 times the nominal capacitor current
VM-60VM-70VM-90VM-100VM-120VM-150VM-180VM-210
Code Size kVAr Steps 800 x 600 x 400 800 x 600 x 400 800 x 800 x 4001115 x 800 x 4001115 x 800 x 4001575 x 600 x 4001575 x 600 x 4001838 x 600 x 400Other standard panels available: 240, 270, 300, 330, 360, 420, 480, 540, 600 and 660kVAr.Standard panels include incoming isolator, controller, protection fuses, contactors and capacitor banks.
607090100120150180210
20 + 20 + 2020 + 20 + 3010 + 20 + 30 + 3020 + 20 + 30 + 3030 + 30 + 30 + 3030 + 30 + 30 + 6030 + 30 + 60 + 6030 + 60 + 60 + 60
Automatic PFC Panels – 400V
kVAr Selection: See AC/DC Website. Energy audit service availableVM-100
kVAr at
WireSize2.5mm2
2.5mm2
2.5mm2
2.5mm2
2.5mm2
2.5mm2
2.5mm2
6mm2
6mm2
6mm2
10mm2
25mm2
25mm2
50mm2
50mm2
50mm2
50mm2
WireSize2.5mm2
4mm2
4mm2
6mm2
10mm2
10mm2
10mm2
16mm2
16mm2
25mm2
25mm2
50mm2
70mm2
70mm2
95mm2
• Maximum THD in Voltage: 2%• Maximum THD in Current: 25%• Discharge Resistance: Incorporated• Dielectric: Metalized polypropylene film• Voltage test between terminals: 2.15 x Un 2sec • Voltage test terminals to case: 3kV for 10 sec AC• Standard EN60831-1/2
Ideal for use with harmonic filters• Terminals –
stud type • Discharge
resistors fitted
Manufactured to EN60831-1/2
Code Ø x Hmm
CurrentA550V
kVAr at400V
Rated Voltage
D2800C550-75C550-100C550-125C550-150C550-200C550-250C550-300C550-400C550-500
70 x 21585 x 21585 x 215100 x 215100 x 215100 x 300120 x 300120 x 300136 x 300136 x 300
3.73A5.59A7.46A9.32A11.19A14.91A18.64A22.37A29.83A37.28A
57.51012.5152025304050
2.643.975.296.617.9310.5813.2215.8721.1526.44
550V550V550V550V550V550V550V550V550V550V
WireSize4mm2
4mm2
4mm2
4mm2
6mm2
6mm2
10mm2
10mm2
16mm2
25mm2
3 Phase Capacitors – Steel enclosed type
POWER FACTOR CORRECTION CAPACITORS
T
WARNING: all PFC systems require protection against harmonics, generated by such devices as variable speed drives and UPS’s, and transient surges including lightning.
187
CA
PAC
ITO
RS
& P
FC
Code RG-8BS RG3-12CS ED8-96
2.557.51012.515202530
RTF-2.5RTF-5RTF-7.5RTF-10RTF-12.5RTF-15RTF-20RTF-25RTF-30
Harmonic Filters are designed to eliminate the 5th (250Hz) harmonic & higher, which can cause damage to three phase capacitors used for power factor correction.
Standards: IEC-289; IEC-076Tolerance “L”: 3%Thermostat Protection: 90°CHeat Insulation Class: Class F (155°C)Insulation Voltage: 4kVMaximum Overload: 1.17 x InMaximum THD in current: 25%Voltage: 440V, 50Hz, Resonance Frequency: 189Hz
CodePower KVAr
3540455060708090100
RTF-35RTF-40RTF-45RTF-50RTF-60RTF-70RTF-80RTF-90RTF-100
CodePower KVAr
THREE PHASE HARMONIC FILTERS
RDM6 RDM12
Last 10 conditions
Capacitor stepsAlarm outputVoltage measurement & supplyFrequencyDisplay typeSizeExternal C.T.ProgrammingRequired COSɸDisplaysRMS voltage & currentCOS ɸOutput relay stepAlarm displaysHigh/low voltageHigh/low currentUnder/over compensationOver voltage/currentUnder compensationCurrent & voltage distortionAlarm memoryTemperatureDual Target CosɸEnergy Ratio AlarmHarmonic Measurement & ProtectionRS-485 CommunicationCompensation Individual phases, separately
8✔
10-500& 230±10%45/65Hz
LED96 x 96
x/5AAuto/Man
Programmable
✔
✔
LED
High Only–✔
Voltage Only✔
✔
✔
✔
✔
✔
✔
✔
–
12✔
10-300& 230±10%50/60Hz
LED144 x 144
x/5AAuto/Man
Programmable
✔
✔
LED
High Only–✔
Voltage Only✔
✔
✔
✔
✔
✔
✔
✔
✔ (3 CTs)
81
230/400V45/65Hz
LED96 x 96
x/5AMan
Programmable
✔
✔
LED
✔
✔
✔
–
61
380/415V50/60Hz
LCD96 x 96
x/5AAuto/Man
Programmable
✔
✔
LED
✔
✔
✔
✔
✔
121
380/415V50/60Hz
LCD144 x 144
x/5AAuto/Man
Programmable
✔
✔
LED ✔
✔
✔
✔
✔
T
POWER FACTOR CONTROLLERS
CA
PAC
ITO
RS
& P
FC
188
Code Max. kVAR
No. ofModules
Size H x W x D
Base Units IP31 Each contains incoming isolator, control fuses, controller plus terminals for external alarm and CT
LND-EVLND1LND2LND3
2562.5137.5200
351116
380 x 425 x 360 390 x 565 x 360 720 x 565 x 3601150 x 565 x 360
LND-EV Max. Steps4 Steps6 Steps6 Steps6 Steps
=
Code kVAR400V
Modular Width
Capacitor Modules – 440V Single Step – for LND1, 2 and 3 Base Units.Each complete with capacitors, contactor, fuses, neon fuse indicators and plug-in connections
JOL-025JOL-05JOL-10JOL-12.5JOL-15JOL-20JOL-25
2.551012.5152025
1111222
Code kVAR400V Steps
JOLEV-17.5JOLEV-20JOLEV-25
17.52025
2.5+5+105+5+105+10+10
*Modular Width333
*Effective value at 400V
*kVAR440V2.14.18.210.312.316.420.5
*kVAR440V14.416.420.5
This compact modular system is both rugged and highly efficient. By ordering a base unit, the steps required plus an external CT,a complete automatic PFC system can be assembled in minutes for fast installation. The components can be stocked by PFC specialists and electrical wholesalers for immediate supply from stock. There is no need for custom engineering or workshop assembly.• Simple ordering, assembly and installation for end users and contractors.• A wide range of systems can be assembled from very few parts.
• Rugged 440V rated capacitors offer long life.• Assembly is simply slide-in, plug-in and go!
+
MountingWallWallWallFloor
3-Step Modules for LND-EV only One module completes the system with LND-EV
NominalkVAR 400V
MaxkVAR 400V
Base Unit Required
204050607580100125150165
20.54151.2557.473.882102.5123143.5164
LND-EVLND1LND1LND2LND2LND2LND2LND3LND3LND3
Free Modules0005331420
MaxkVAR 440V255062.57090100125150175200
Recommended Combinations – Many other kVAr combinations can be created to suit application requirementsModulesRequiredJOLEV-25 x 1JOL-10 x 1 + JOL-20 x 2JOL-12.5 x 1 + JOL-25 x 2JOL-20 x 1 + JOL-25 x 2JOL-15 x 1 + JOL-25 x 3JOL-25 x 4JOL-25 x 5JOL-25 x 6JOL-25 x 7JOL-25 x 8
Steps5+10+1010+20+2012.5+25+2520+25+2515+25+25+2525+25+25+2525+25+25+5025+25+50+5025+50+50+5025+25+50+50+50
• Supply & control voltage Vn, 400V• Capacitor rated voltage, 440V• Maximum over voltage during a 24hr
period – For 8hrs 484V – For 30mins 506V
– For 5mins 528V – For 1min 570V
• Maximum over current 1.3 x In• Maximum current distortion (TDHI)
– Peak 40% – Continuous 10%
• Ambient -15 to +35°C• Operating temperature
– Peak 55°C – Maximum 24hr average 45°C – Maximum yearly average Deg., 35°C
• Loss <0.4W/kVAr
• Life expectation is 30 000hrs x (25 ÷ D)
• Standards: IEC 60439-1, IEC 60831-1
Specifications
LND1
LND2 LND3
For external CTs, see page 167. For harmonic filters, see page 188.
T
MODULAR POWER FACTOR CORRECTION SYSTEM
189
CA
PAC
ITO
RS
& P
FC
Features• 2 x 7 digit LED displays:
PV (Process Value) REDSV1 (Set Point Value) GREEN
• Measure range: multi-range and pre-scalable• Input types: TC (J, K, R, S, T,...)
RTD (PT100...) 0-10V, 1-5V, 4-20mA
Connection Diagram for TZN4M
• SV2 input for oven door interlock• Indicating accuracy of ±0.3% ( F - S)• Dual PID function selectable fast response
PID action (PIDF) or slow response PID action (PIDS)
• Control: ON/OFF, P, PI, PD, PIDF, PIDS con-trol
SpecificationMulti-volt Supply: 100 to 240VACConsumption: 5VAControl Relay output: C/O 3A @ 250VACSampling time: 250ms
Universal 4 digit temperature controller – Dual indication (full PID controller)
48 x 48TZ4ST-14RTZ4ST-14CTZN4S-24R
72 x 72 / 96 x 96TZN4M-14R TZ4L-14RTZN4M-14C TZ4L-14CTZN4M-24R –
96 x 48TZ4H-14RTZ4H-14C
–
48 x 96TZ4W-14RTZ4W-14CTZ4W-24R
Size (H x W)Control Relay & Alarm Relay4-20mA output & Alarm RelayControl Relay + 2 Alarm Relays
IndicatorType Indicator 5 Sensor Input Indicator Indicator
Size
Supply Volts
Code: PT100Code: JCode: K
Temperature Range
72 x 72mm 96 X 96mm
110-230VAC
SG-781*P SG-681*P SG-781*J SG-681*J SG-781*K SG-681*K
*Add temp range100, 200, 400°C
48 x 96mm
110-240VAC
T4WM-400PT4WM-500J
T4WM-1200K
–
36 x 72mm
100-240VAC
T4YI-400PT4YI-500J
T4YI-1200K
–
24 x 48mm
12-24VDC
T3NI-400P––
–
Connection Diagram for TZ4H
Indicator
34 x 76mm
230VAC
MTR10-599PMTR10-999JMTR10-999K
–
Connection Diagram for TZN4SControlO/P ‘C’
PID TEMPERATURE CONTROLLERS
TEMPERATURE INDICATORS
48 x 48TZN4S-14RTZN4S-14CTZN4S-24R
TC
TEM
PER
ATU
RE
CO
NTR
OLS
190
Technical specificationSupply: 110/220VACInput: Thermocouple K, J and PT100Accuracy: 1% of full scale
Connectiondiagram
Control: On/Off actionOutput: Relay 1C/O 5A@250V Hysteresis: 2,5% full scaleAlarm: 10% of full scale
Analog Setting Analog Setting & Deviation Display
Analog Setting & Full Scale Display
Thumbwheel Setting & Digital Display
–SG-714*SG-612*
–
–*Add temperature 100, 200, 400 or 600°C and Probe type PT100., J or K e.g. SG-622 400J
–SG-724*SG-622*
–
–
– – – SG-742* SG-632* – – –
800 & 1200°C
–SG-771*SG-671*
SG-771/A*/SG-671/A*
–
Size 96 x 48Size 72 x 72Size 96 x 96
Range & ProbeHigher Range ‘K’
ON/OFFControl
With alarm72 x 72/ 96 x 96
Connection diagram
All supplied complete with Y-50 mounting bracketSpecifications: Supply voltage 110-240VAC Hysteresis 2,5% full scale Relay output: 1 C/O @ 2A 250VACPanel-mount or 8 pin plug-in.
Reversed 8 pin P3G-08
Digital 1 Set Point
Transparent cover for 72 x 72VJ4482
Adaptor for 72 x 72 to 96 x 96VJ4458
Digital 2 Set Point Thumbwheel 1 Set Point Analog 1 Set Point
SizeProbe PT100Probe J & K
72 x 72mmVM6251 -99° to 999°CVM6392 -99° to 999°C
72 x 72mmVM6269 -99° to 999°CVM6400 -99° to 999°C
48 x 48mmTP-48*P *100, 200, 400°CTP-48*J *200, 400°C
TP-48*K *200, 400°C
48 x 48mmTR-48*P *100, 200, 400°CTR-48*J *100, 200, 400°C
TR-48*K *100, 200, 400°C
ON/OFFControl
When using 2-wire PT100 Probe, short circuit terminals 4 and 5
SupplyVolts
Connection diagram
IP54
Digital
34 x 76mmMTR11-150PTC*
–
–• Supply: 230VAC* C/W ProbeRange: 50-150°CSpare Probe: PTC150
For blind temperature controllers, see page 67.
SG-861*––
SG-861/A*
–
• Direct/Reverse PWM & Neutral zone operation
Technical specificationSupply: 24 or 230VACInput: Thermocouple K, J & PT100Accuracy: 1% of full scaleOutput: Relay C/O 8A@250V• Min/Max Alarms• Differential or Hysteresis
programmable
TC
TEMPERATURE CONTROLLERS
191
TEM
PER
ATU
RE
CO
NTR
OLS
Code Current KW
Voltage Control for Heaters Single Phase (230V)
Three Phase (400V)
SpecificationsInput Signal: 4-20mA, 0-20mA, 1-5VDC. 0-5VDCControl System: Phase controlInsulation Resistance: 500VDC (10g ohms)
Output Voltage: 0-100%Constant- Voltage Characteristics: Output accuracy 1%Ambient Temperature: -10/50°C Humidity 90% RH belowVR1: Min V output Ads.VR2: Max V output Ads.
Benefits• Small size, saving space • High accuracy and fast response• Eliminates contactor noise • Extends heater life • High efficiency, no maintenance • Maintains stable process
temperature
SG-027SG-057
27A57A
612.5
Ultra fast Fuse30A60A
Code Current KWSG-100SG-132SG-162
100A132A162A
2229.336
Ultra fast Fuse100A160A160A
Code LoadCurrent KW
SG-325SG-350SG-375
25A50A75A
16.53349
Ultra fast Fuse25A50A75A
Code KWSG-3100SG-3130SG-3160
100A130A160A
6686105
Ultra fast Fuse100A160A160A
LoadCurrent
Connection Diagram
Thermocouples NOTE: Wire ColoursJ: White & White with Yellow Stripe
K: White & White with Red StripePT100: 2 x White, 1 x Red
Probe size 100mm x 5.0 ØCable: 1.5m
Thread size 1/4” or 1/2”Cable: 1.5m
Probe: 1/2” Thread150mm x 5.0 ØSteel Braided Cable PVC Coated
ProbeType
PT100
PT100PT100
Type JType K
TC-P/S*
TC-J/S*TC-K/S*
TC-P 100DStd 1/4” threadTC-P 200D*TC-P STEELStd ¼” threadTC-J*TC-K*
100°C
200°C400°C
400°C400°C
PVC
PVCSteel
SteelSteel
Thermo-coupleType
ScrewTypeCode
KSE-P
KSE-JKSE-K
Head TypeCode
TC-P2 CABLETC-P4 CABLE
TC-J CABLETC-K CABLE
Code
200°C PVC coated Grey400°C Steel braided
400°C Steel braided400°C Steel braided
DescriptionTempRange
400°C
400°C400°C
TempRange
CableType
Installationexample
Temperature Transmitter (2 wire)
TRT-PT100*TRT-J*TRT-K*
SpecificationOutput Signal: 4 - 20mA DCPower Supply: 12 - 40VDCAccuracy: ±0.15% F.S. (PT100) ±0.5% F.S. (J & K)
Steel Cable
PVC Cable
*Specify 1/4” or 1/2”
Com-pression Clamp
Thermocouple Connectors
FemaleFPL-PT100FPL-JFPL-K
MaleMPL-PT100MPL-JMPL-K
1/2” BrassCC-02B
1/4” BrassCC-04B
1/2” S/SteelCC-02S
1/4” S/SteelCC-04S
Code
Probe size 100mm x 5.0 ØCable: 1.5m
*Specify 1/4” or 1/2”
KEN-P
KEN-JKEN-K
Large HeadCode
TEMPERATURE PROBES
SCR HEATER ELEMENT REGULATORS
*Add Temperature range PT100: 50, 100,150, 200, 400°C J: 100,150, 200, 400, 600°C K: 100,150, 200, 400, 600, 1000, 1200°CFits into Head Type KEN-P, J or K
TC
RHE
TEM
PER
ATU
RE
CO
NTR
OLS