*Add supply Voltage: A: 230VAC, B: 24VDC Supplied with separate power supply 4 Points 5 Points 6 Points 6 Points 8 Points 12 Points 14 Points 16 Points 22 Points 24 Points Accessories With Pushbuttons Red Perspex window 30x30mm c/w LED Block Yellow Perspex window 30x30mm c/w LED Block Green Perspex window 30x30mm c/w LED Block AL-3030-R AL-3030-Y AL-3030-G Small Window no Pushbuttons Large Window no Pushbuttons 12B2SPO-* 10B4SPO-* 10B6SPO-* 26B0SPO-* 20B14SPO-* 30B22SPO-* 10B8S00-* 20B16S00-* 30B24S00-* 14B0S00-* 28B0S00-* 312B0S00-* 416B0S00-* 624B0S00-* Code Description Monitors potential free input contacts (NO or NC) 4 to 16, for any change of status (Abnormal) & activates one common output relay for audible device with respective flashing LED windows, thus indicating the “Alarm” status. This flashing annunciation window is “Acknowledged” & “Reset” (when returns back to normal) by external push buttons. • Powerful Microprocessor Circuit. • Optically Isolated input Circuit. • Low Power Consumption. • Two Window Sizes, Big & Small. • Built-in system watchdog LED. • Super Bright LEDs. • Fully integrated construction. • NO/NC selectable input configuration. • AC/DC auxiliary supply. • DIN standard panel cutouts. • Front replaceable windows & Inscriptions. • Moulded enclosures. Specifications Aux. Supply: Input: Output: Rating: Facia Window Size: Flash Rate: 24/48V DC / 110/220V AC Potential Free Contacts (NO or NC Site Configurable) 1 NO for Audible Hooter 5A, 230V AC Resistive Big: 60 x 30mm Small: 30 x 30mm Fast: 60 Flash/Min. Slow: 30 Flash/Min. LED: Interrogation Voltage: Response Time: Power Consumption: Grouping (Trip/Non Trip): Colour Red (Amber/Green on request) 12V DC 25m.sec. ±10m.sec 1.5W/Window Optional 12B2SPO 10B4SPO 10B6SPO 26B0SPO 10B8S00 20B16S00 28B0S00 312B0S00 14B0S00 416B0S00 Printing of Front Replaceable Windows 30 x 30mm transparent film 60 x 30mm transparent film AL-30 AL-60 Code Description • Black letters on transparent film to be sandwiched between front & rear difusers Cutout Size 68x138 68x138 68x138 138x138 138x138 210x138 Cutout Size 68x138 138x138 210x138 Cutout Size 68x138 138x138 210x138 282x138 2x(210x138) ALARM ANNUNCIATORS Red Perspex window 60x30mm c/w LED Block Yellow Perspex window 60x30mm c/w LED Block Green Perspex window 60x30mm c/w LED Block AL-6030-R AL-6030-Y AL-6030-G Code Description Description Code Supply Size 8-Channel Annunciator 8-Channel Annunciator 10-Channel Annunciator M4100-12 M4100-22 M1000-24-00C 12VDC/AC ±30% 24VDC/AC ±30% 12-24VDC 96x96 96x96 144x144 8 & 10 Channel Alarm Annunciator • Input contact type NO/NC and delays 0-15 secs are selectable individually on all channels. • Two common output relays for siren and alarm with voltage free contacts. • Legend can be typewritten on the label easily accessible behind front plate. • Two integrated push buttons for siren reset/lamp test and alarm accept. Remote individual selectable blocking with adjustable unblocking delay 0-15 secs. • Plug-in terminal block for easy service. • DC or AC supply voltage. Specifications for M4100 • Consumption: 0.15A • Temp Range: -20˚ to +70˚C • Minimum input delay: 50ms Accessories for M4100 Front cover with handle IP54 M0846-00 Front cover with key IP54 M0846-01 Specifications for M1000 • Output relay : Max. 220V AC/2A • Output : Max. 150mA per channel • LED flash frequency : Slow Flashing Light 0.8Hz ±10% Quick Flashing Light 8Hz ±10% • Programming : Switches on rear of unit • Reset/Lamp Test : Via Pushbuttons • Power Consumption : 180mA M4100 M1000 DPM 177 INSTRUMENTS

Transcript of ACDC Pages 177-192 (low res).pdf

Page 1: ACDC Pages 177-192 (low res).pdf

*Add supply Voltage: A: 230VAC, B: 24VDC †Supplied with separate power supply

4 Points5 Points6 Points6 Points8 Points12 Points14 Points16 Points22 Points24 Points

Accessories

With Pushbuttons

Red Perspex window 30x30mm c/w LED BlockYellow Perspex window 30x30mm c/w LED BlockGreen Perspex window 30x30mm c/w LED Block

AL-3030-RAL-3030-YAL-3030-G

Small Window no Pushbuttons

Large Window no Pushbuttons

12B2SPO-*10B4SPO-*10B6SPO-*26B0SPO-*

––

20B14SPO-*–

30B22SPO-*–

––––

10B8S00-*––

20B16S00-*–

30B24S00-*

14B0S00-*–––

28B0S00-*312B0S00-*

–416B0S00-*

–†624B0S00-*

Code Description

Monitors potential free input contacts (NO or NC) 4 to 16, for any change of status (Abnormal) & activates one common output relay for audible device with respective flashing LED windows, thus indicating the “Alarm” status. This flashing annunciation window is “Acknowledged” & “Reset” (when returns back to normal) by external push buttons.• Powerful Microprocessor Circuit.• Optically Isolated input Circuit.• Low Power Consumption.• Two Window Sizes, Big & Small.• Built-in system watchdog LED.• Super Bright LEDs.

• Fully integrated construction.• NO/NC selectable input configuration.• AC/DC auxiliary supply.• DIN standard panel cutouts.• Front replaceable windows & Inscriptions.• Moulded enclosures.

SpecificationsAux. Supply:

Input:Output:Rating:Facia Window Size:Flash Rate:

24/48V DC / 110/220V ACPotential Free Contacts (NO or NC Site Configurable)1 NO for Audible Hooter5A, 230V AC ResistiveBig: 60 x 30mm Small: 30 x 30mmFast: 60 Flash/Min. Slow: 30 Flash/Min.

LED:

Interrogation Voltage:Response Time:Power Consumption:Grouping (Trip/Non Trip):

Colour Red (Amber/Green on request)12V DC

25m.sec. ±10m.sec1.5W/WindowOptional

12B2SPO 10B4SPO 10B6SPO 26B0SPO 10B8S00 20B16S00 28B0S00 312B0S00

14B0S00 416B0S00

Printing of Front Replaceable Windows

30 x 30mm transparent film60 x 30mm transparent film

AL-30AL-60

Code Description

• Black letters on transparent film to be sandwiched between front & rear difusers

Cutout Size

68x138 68x138 68x138138x138

138x138

210x138

Cutout Size

68x138

138x138

210x138

Cutout Size

68x138

138x138210x138

282x138

2x(210x138)

ALARM ANNUNCIATORS

Red Perspex window 60x30mm c/w LED BlockYellow Perspex window 60x30mm c/w LED BlockGreen Perspex window 60x30mm c/w LED Block

AL-6030-RAL-6030-YAL-6030-G

Code Description●

Description CodeSupply Size8-Channel Annunciator8-Channel Annunciator10-Channel Annunciator

M4100-12M4100-22M1000-24-00C

12VDC/AC ±30%24VDC/AC ±30%12-24VDC

96x9696x96144x144

8 & 10 Channel Alarm Annunciator• Input contact type NO/NC and delays

0-15 secs are selectable individually on all channels.

• Two common output relays for siren and alarm with voltage free contacts.

• Legend can be typewritten on the label easily accessible behind front plate.

• Two integrated push buttons for siren reset/lamp test and alarm accept.

• Remote individual selectable blocking with adjustable unblocking delay 0-15 secs.

• Plug-in terminal block for easy service.• DC or AC supply voltage.

Specifications for M4100• Consumption: 0.15A• Temp Range: -20˚ to +70˚C• Minimum input delay: 50ms

Accessories for M4100Front cover with handle IP54 M0846-00 Front cover with key IP54 M0846-01

Specifications for M1000

• Output relay : Max. 220V AC/2A• Output : Max. 150mA per channel• LED flash frequency : Slow Flashing Light 0.8Hz ±10% Quick Flashing Light 8Hz ±10%• Programming : Switches on rear of unit• Reset/Lamp Test : Via Pushbuttons• Power Consumption : 180mA

M4100 M1000

DPM 177

INST

RU

MEN

TS

Page 2: ACDC Pages 177-192 (low res).pdf

M90 extended family of PLCs extends to 158 I/0, GSM and MODbus communication, with embedded graphic operator panel. PLC & HMI programmed with one programme! All models supplied with software, instruction manual, cable & connectors.

Expansion Modules

Accessories

For power supplies, see page 69.

OPLC-GSM-K1M90-19-R4V200-19-ET1

GSM modem, magnet antenna, cables and adaptorsRS232 to RS422/485 converterEthernet module for PLC V230 & V260 only

Communication OptionsEX-A1IO-DI8-TO8IO-AI4-AO2IO-DI8-RO4IO-DI16IO-TO16IO-RO8EX90-DI18-RO8IO-PT4

Expansion Adaptor8 Digital Inputs, 8 Transistor Outputs4 Analog Inputs, 2 Analog Outputs8 Digital Inputs, 4 Relay Outputs16 Digital Inputs16 Transistor Outputs8 Relay Outputs8 Digital Inputs, 8 Relay Outputs4 PT100 Inputs, -42 to 112°C

M90-R1

M90-R1

-CAN

M90-R2

-CAN

M90-T1

M90-TA

2-CAN

V120

-12-R1

V120

-12-R2

C

V120

-12-UN

2

V230

-13-B2

1

V260

-16-B2

1

1 line x 16 characters80

15

2048 words

256256

–64–

12µsec

1 portRS232/485 converter supplied

– 1 port 1 port – –

Up to 6 phone numbers, up to 1k of user defined messages

8 PNP 10 PNP2 (16 bit)

12 24 – 25

– 6 – – 11 8 – 1 (0-10V) – 1 (1.5kHz) –

Up to 64 extra I/O via 8 expanders

24VDC96 x 96

8 lines x 22 characters 128 x 64p255

16

16k words

10241024256

128 (32 bit)64 (32 bit unsigned)

0.8µsec

2 ports1 port

– 1 port –Master/slave protocol

Up to 8 phone numbers

7 PNP/NPN 8 PNP/NPN 3 (32 bit) 2 (32 bit) 12 22 (2 below)

26

6 – – 10

– – 2 (2kHz)

12/24VDC96 x 96

128 x 64p 240 x 64p100

24 33

16k words

20481600256192

64 (32 bit unsigned)0.8µsec

2 ports1 port1 port

Master/slave protocolUp to 8 phone numbers

16 PNP/NPN2 (32 bit)

33

–10

4 PNP/NPN–

2 (50kHz) NPN

12/24VDC218 x 184 260 x 184

Notes: 1) High speed counter/shaft encoder/frequency measurer of normal digital inputs, 10kHz max. Can be used as normal digital input. 2)10 bit analog input: 0-5V, 0-10V, 0-20mA, 4-20mA. 3) 10 bit analog input: 0-10V, 0-1mA, 4-20mA,4-20mA. 4) 10 bit analog input: 0-5V, 0-10V. 5) 10 bit analog input: 0-10V. 6) 14 bit universal input for thermocouple, PT100, 0-10V, 0-20mA, 4-20mA.

Up to 128 I/O extra via 8 expanders

• RS232/485 Up to 64 mixed M90 family units

• CANbus • MODBUS • GSM/SMS control • Remote access with any

phone-line modem

DisplayResolution (Pixels)HMI displayKeyboardNo. of keysProgrammePLC sizeReal time clockCoilsRegisters/integers32 bit integersTimersDouble wordExecution timeCommunicationRS232RS485CANbusMODBUSGSMI/OsDigital inputsHigh speed inputAnalog inputThermocouple/PT100Relay outputspnp outputsAnalog outputsHighspeed outputI/O expansionGeneralPower supplySize mm

Real-time clock functions (date and time) with 7 year battery backup – all models

IP65 when panel mounted

One Windows-based program for both PLC & HMI

Note: when using expansion modules expansion adaptor must be installed

DPM

MICRO PLCs

INST

RU

MEN

TS

178

Page 3: ACDC Pages 177-192 (low res).pdf

The Lm Micro Series PLC is comprised of various modules. The basic functional configuration requires a CPU module working as a basic unit, in comple-ment with optional expansion modules such as communication modules, digital I/0 modules and analogue I/0 modules

Expansion Modules

AccessoriesLS3601LA3801-COM-300LA3810HT6100HD2100

LM PLC & HMI Programming Software CDLM Communication Cable - RS-232 Cable (2m)LM Expansion Module (500mm length)HMI USB Programming cableRS-232 Serial programming cable

Communication Options

LM MICRO SERIES PLCs

LM3210-EDILM3211-EDIALM3220-EDOTLM3222-EDORLM3221-EDOTLM3223-EDORLM3310-EAILM3320-EAOLM3401LM3403

8 Digital 24VDC input module8 Digital 230VAC input module8 Digital 24VDC solid state output module8 Digital 230VAC /24VDC relay output module16 Digital 24VDC solid state output module16 Digital 230VAC/24VDC relay output module4 Channel Analog input module4 Channel Analog output moduleProfibus DP slave interface moduleEthernet interface module

LM31

04

LM31

05

LM31

06

LM31

07E

LM31

09

LM32

30-ED

MTLM

3231

-EDMR

LM33

30-EA

M

HT66

00C

HT68

00T

24VDC 240VAC 24VDC 240VAC 240VAC125(L) x 90(W) x 70(H)mm

Unlimited number of counters, 15 bits counting rangeUnlimited number of timers, 1ms to 49days

0.37µs per instructionReal time clock function, 10 years back-up

60 000 words

1 1 1 1 1 – – – – 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

5 5 11 9 21 3 3 3 3 3 – – – 2 – – 6 – 8 16 6 – 10 – 1 – – – 1 –1Point,20kHz – 2Points,20kHz – – 2 2 4 4 7

Expansion Modules21-28VDC

192 x 138mm 224 x 161mm

320 x 240 640 x 48010 000hrs

200mHz RISC

128k WordsCommunication

RS232RS485ModbusG-Mode

I/OsDigital Inputs

Digital High Speed InputsAnalog Input

Relay OutputsPNP Outputs

Analog OutputPulse Output

Max Expansion Module

GeneralHMI Display

50(L) x 90(W) x 70(H)mm

12bitA/D10 000 000 Open/ Close

<10ms <10ms <10ms

65535words

– – –– – –– – –– – –

4 4 –– – –– – 4– 4 –4 – –– – –– – –– – –

CPU ModulesPower Supply

SizeProgramme

ResolutionTimers/ LifespanExcecution timeReal Time Clock

PLC Program Size

Code Description

Catalogues & ManualsLD3000LD3001LD3002HT6101LM3101HMI101

LM Micro Series PLC - Hardware ManualLM Micro Series PLC - Software ManualLM Micro Series PLC - Instruction ManualHMI User GuideComplete software & infoComplete software & info

Connections

DPM

Programming Languages• Instruction List (IL) • Function Block Diagram (FBD)• Sequence Function Chart (SFC) • Structual Text (ST)• Ladder Diagram (LD) • Continuous Function Chart (CFC)

Connection to expansion modulesWiring terminal for output + input power supplyWiring terminal for input + output power supplyRS-232/RS-485 communica-tion portRUN/STOP operation switch + analogue presetsI/O channels status indicatorPLC status indicator - Run, Stop, Com, ErrorHeat radiatorDIN Rail fastenerHole for backplane or wall mounting

12

3

4

A

BC

DEF

179

INST

RU

MEN

TS

Page 4: ACDC Pages 177-192 (low res).pdf

Rotating Disc kWh Meters 0142 Authorisation No. 0102402

1-Phase 230V Range 3-Phase 380V+N Range

6 Digit register Metal Base and Polycarbonate coverLower bearing is magnetic suspension type

HX12D-40 10-40AHX12D-60 15-60AHX12D-80 20-80ASize (mm): 160H x 122W x 126D

HX34D-80 20-80AHX34D-100 30-100AHX34C CT-5ASize (mm): 260H x 170W x 135D

HX12D-40/60 HX34

DDS223-63 DDS722-100 DTS722-60/100

Mechanical Counter kWh Meters

3-Phase 400V+N Range Size Pulse/kWDTS722-60DTS722-100

Digital kWh Meters

3-Phase 400V + N

DDSF223-30DDSF223-63DDSF722-60

1-Phase 230V

DSS722-5DSS722-60DSS722-1001m=17.5mm Wide

• Pulsed output 3200 Imp/kWh • Class 1

DDSF722-60 DSS722-5/ 60/ 100

Range Size Pulse/kW

3-Phase 400V+N

5-30A 1m 20005-63A 2m 20005-100A 3m 800

DDS223-30 DDS223-63 DDS722-100

1-Phase 230V

Range Size Pulse/kW5-60A 6m 3205-100A 6m 160

Range Size Pulse/kW5-30A 1m 2000 5-63A 2m 2000 5-60A 3m 1600

Range Size Pulse/kW1.5-5A (CT) 6m 16005-60A 6m 3205-100A 6m 160

Pre-payment kWh Meters

Code DescriptionDDSY238-60DTSY238-60

DTSY238-80

Single Phase3-Phase4 wire 400V+N3-Phase meter.4wire 400V+N

• Power failure memory • Direction of power indication• Anti-theft function • Coded card for fraud protection• Software requires Windows XP© or Windows 7©

Accessories

Code DescriptionDDSY-CDDSY-P

Amps15-60A15-60A

20-80ADDSY-C

OutputPulses/kW1600200

100

DDSY-P

Pre-payment CardCard readers. c/w program software

Code Size Accuracy DisplayECR-3-72ECR-3-96

72 x 7296 x 96

1% ±1 digit1% ±1 digit

4-digit 14.2mm high4-digit 14.2mm high

CT-Ratio.../5A.../5A

Range0.00-0.990.00-0.99

Digital Power Factor MeterOperating

Voltage230VAC ±10%230VAC ±10%

Non-flammable enclosureFlush mounting with rear terminals

DPM

PRE-PAYMENT kWh METERS

POWER FACTOR METER

kWh METERS

DDSF223-30 DDSF223-63DDS223-30

INST

RU

MEN

TS

180

Page 5: ACDC Pages 177-192 (low res).pdf

Supply Voltage UnCurrent, (I max)Operating CurrentFrequencyOperating VoltagePower ConsumptionPrecision accuracy classPulse transmissionRecorded harmonicsSize: 1M = (17.5mm)Digits

230VAC5(25)A

0.02 to 25A50/60Hz

195 to 253V0.5VA

Class 1Type SO

Until 7kHz1m5+1

230VAC5(32)A

0.02 to 32A50/60Hz

195 to 253V0.5VA

Class 1Type SO

Until 7kHz2m5+1

230VAC10(63)A

0.04 to 65A50/60Hz

195 to 253V0.5VA

Class 1Type SO

Until 7kHz2m5+1

MODULAR ENERGY METER (kWh)

Code CONTAX 2511 CONTAX 3221

• DIN Rail Mount• Operating Temp:

-20 to 50°C

CONTAX 6521

CodeW, Wh orVA, Vah or ELF3234VAR, VARh orPF

W, Wh, PF orVA, Vah,PF or ELF3234-3VAR, VARh, PF

V, A, F ELF3259

• Inputs (V), 110 or 400VAC Range: 80-500V 3 Phase 4 Wire

• Input (I) 1A or 5A programmable• Supply Volts: 80-270VAC @ 3VA

Accuracy: 2% for VARh All others: 1%

• Phase wise & total RMS for power, total for Energy Meters

• 10 year back-up of integrated data• VA function selectable 3D or Arithmetic• V shows all Line-Line, Line-Neutral,

Individual & Average Voltages• Size: 96 x 48 x 40(D)mm

1C15WRPkWh and kVARh3 Phase 400V + N

Indication (Active and Reactive Power)

• 7 Digit Electro-mechanical display• Accuracy: 2% (kWh)

3% (kVARh)

230VAC40 (80)A0.08-80A50/60Hz230VAC

<2VAClass1

1000lmp/ kwh–

1m6+1

ES-80L

PM-KW10-99kW Indicator

• c/w 16A Plug & Socket• Ideal to check your kW

usage from generator etc.

c/w 80A CT

kWh METERS

230VAC5 (32)A

0.02-32A50/60Hz230VAC

<2VAClass1

1000lmp/ kwh–

1m6+1

ES-32L

c/w tamper-proof terminal seal

1 x kWh 1C15WP3 Phase 400V + N

kWh MeterC/T Ratio selectable by DIP SwitchSelectable Primary CT Current:

5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300, 400, 500, 600, 750, 800, 1000, 1200, 1250, 1500,

1600, 2000, 2500, 3000, 4000, 5000, 6000• 7 Digit Electro-mechanical display

• Accuracy: 2%• Pulsed Output

2 x kWh 1C15WP2

DPM

RIMD.W15230VACCT.../5A60, 100, 150, 250, 400, 600, 1000/5A50/60Hz195 to 253V4VA2m3

Supply Voltage UnCurrent, (I max)Operating Current

FrequencyOperating VoltagePower ConsumptionSize: 1M = (17.5mm)Digits

CodeDigital Power kWh MeterkWh Indicator

181

INST

RU

MEN

TS

Page 6: ACDC Pages 177-192 (low res).pdf

Zaptronix kWh Meters

Energy & Maximum Demand• kWh, kVAh, kVArh • kW and kVA • Block & Moving window

ZAP03BE-MD only• Data & Event logging • RS232 • Pulse output• Time of use

Features:Measurement parameters• Watt, VAr, VA (Import/Export & per phase)• Volt, Amp, Power Factor, Frequency

kWh Meter + Maximum Demand

Code System V Range Amps Accuracy

ZAP1CSZAP1CS-R

1ph, 2-wire, 230V1ph, 2-wire, 230V with RS485 Serial Port

Type

BS

BS

184-275V

184-275V

100A

100A

10-100, Class 1

10-100, Class 1

ZAP03BE-MD* 3ph, 4-wire, 230/400V 184-275V (L-N) 5A 1-5/6, Class 1

ZAP03BS / ZAP03BE-MD / ZAP03LM

ZAP03DS

AccessoriesZAP-EDAT • EDAT+g for GSM-GPRS AMR at multi meter (up to 128) Installations ZAP3AM, ZAPICS, ZAP03LM • EDAT+e for Internet AMR at multi meter (up to 128) installations ZAP1CS, ZAP3AMZAP-SOFT Remlt! Lite Programming Software CD. – download for free. Can be downloaded from

www.zaptronix.co.za/downloads, This is for ZAP03DS , ZAP03BE, ZAP03BS ZAP-OPTO Optocoupler RS232 for BS type housingZAP-OPTO/USB Optocoupler USB for BS type housing*ZAP-PRO Factory programming for ZAP kWh meters (free service)ZAP-MPS (MPS) Meter reading & configuration software. Free download from www.zaptronix.co.za This is for ZAP03AM, ZAP1CS

kWh METERS

Single Phase High Load (100A) Direct Connect, Class 1 Accuracy Billing Meter

ZAP-OPTO

BS

*Note: All 3-phase meters must be programmed before use

Features:• Billing meter for active (kWh) import & export energy • 3 Phase , CT and VT connected Meter• Low cost, no maintenance required • Large , Multi function LC -Display• Easy Meter Communication via Infrared flag port• Engineering software included/ available for download at no charge

Mounting

DIN Rail

Din Rail

ZAP03DS*ZAP03BS*

3Ph, 4 wire, 230/4003Ph, 4 wire, 230/400

DINBS

184-275V (L-N)184-275V (L-N)

5A5A

1-5/6, Class 11-5/6, Class 1

Three Phase Active Energy Meter (CT-Connected)DIN RailBase Mount

Base Mount

Features:As per ZAP03BE-MD plus: I/O; 2 x I/P MD synch, E01, water or gas pulse (programmable); 4 x O/P load shedding, rated for 20mA @ 30VDC.Additional Registers:• Target demand • Interlock timer • Load priority setting• Percentage Hysteresis • Override • Load switching frequency

kWh Meter + Maximum Demand + Load Management (Load Shedding)

ZAP03LM 3ph, 4-wire, 230/400V (L-N) 5A 1-5/6, Class 1BS Base Mount

ZAP3AM5/PZAP3AM100ZAP3AM160

3Ph, 4 wire, 230/4003Ph, 4 wire, 230/4003Ph, 4 wire, 230/400

–––

230V/400V230V/400V230V/400V

5A100A160A

1-5/6, Class 110-100, Class 110-160, Class 1

PI-Range Profiling - Energy Demand Logging Multi-tariff Meter - IEC 62053-21Base MountBase MountBase Mount

Features:• Billing meter for active (Wh) and reactive (VArh) energy demand (VA)• Flexible multi-tariff (TOU) billing meter with auto registration• Profile logging of total energy and average energy demand

ZAP3AM5 230VZAP3AM5 110V

3Ph, 4 wire, 230/4003Ph, 3 wire, 110V (P-P)

––

230V/400V110V-480V

5A5A

1-5/6, Class 11-5/6, Class 1

Lambda-Range Logging - Energy Demand Logging Multi-tariff Meter - IEC 62053-21Base MountBase Mount

Features:• 4 Quadrant, billing meter for active (Wh) and reactive (VArh) energy demand (VA)• Data storage of last 16 months energy and maximum demand for 4 tariffs• Load profile with integration period 1, 5, 30, 60min• Event registration of power outages, per phase voltage loss, under/ over voltage• Full multi-tariff (TOU) billing meter with auto registration• Extensive 6 channel logging from 32 readings and event recording• Remote automated meter data acquisition via IP or GSM-GPRS/SMS

ZAP1CSZAP1CS-R

ZAP3AM

*Add 110V for 3 phase system 3PH, 3 Wire, 88-132V (P-P)

*Add 110V for 3 phase system 3PH, 3 Wire, 88-132V (P-P)

• Remote automated meter reading ready (ZAP1CS-R)

• Remote automated meter reading ready with ZAP-EDAT

DPM

INST

RU

MEN

TS

182

Page 7: ACDC Pages 177-192 (low res).pdf

White (or green/ Yellow) Wire to Phase

Blue wire to Blue phase

Black Wire to Neutral

Red Wire to Geyser

Ditto for other controllers

White (or Brown) wire to Seconary side of Geyser C/B (or Isolator)

Red (or Brown)Wire to Red Phase

DPM

ENERGY SAVING CONTROLLER

Code

Monitor your own electricity and save power and money!

AML-1208 • 1 x Current sensor• 1 x Sender unit• 1 x Display unit

With the standard electricity In-Home-Display unit, you can clip the current sensor around the electricity meter's live feed supply such that it measures the total electrical power entering your home or office. Power consumption will be recorded and transmitted to the display unit wirelessly.The following features are provided also: • Dual battery system is used to extend operation period and to prevent data lost during battery changing • Indicate existing cost alert level by Tri-color LED • Display temperature and current time • Clock alarm and cost alert level setting • Monitor up to 8 sensors • Support >30m RF transmission• 4 x Batteries

• 1 x User Manual• 1 x Desk Stand

This product is a semi-portable communication product used in the household market. You can view the instant electricity consumption, cost-up-to-current-hour and records (eg. hourly, daily, weekly, and monthly) as well as estimated CO² emission produced. Transmitting frequency 433mHz with proprietary communication coding for different market segments.

(1-Phase) Monitoring System

Geyser Controller with Embedded Microprocessor

WIRELESS POWER DISPLAY UNIT

Geysers are the largest user of electricity in most households using up to 60%. GC-100 geyser controller will save 40%-60% of geyser usage.

Code GC-100Features • Immediate saving from first monthly bill.

• Ensures geyser is off during peak periods• Back-up battery to retain memory• Override switch geyser off and on• 8 Pre-programmable time periods

Technical Info• Input Voltage: 220/ 240VAC 50Hz• Mounting: Din Rail• Memory: 120 day battery• Current Sensor: 20Amps• Relay output 20A

Passive Power Factor CorrectionPower Factor Correction (PFC) is a technique of counteracting the undesirable effects of electric loads that create a power factor less than one. This range of passive (PFC) units can save 10%-20% of energy consumpion.

Code DescriptionES15ES100ES300ES3001ES3002

Single-Phase (1000kwh) 16A SA plug-in typeSingle Phase (2000kwh)Three-Phase (6200Kwh)Three-Phase (10 000Kwh)Three-Phase (15 000Kwh)

Technical InfoSingle-Phase voltage: 220-240VAC 50HzThree-Phase voltage: 380-420VACOperating temperature: 60˚C (max.)

Features Prolongs life of appliancesStabilise electrical currentAvailable in single and three-phaseSuitable for home, shops, offices, restaurants, etc.

Combination Geyser/ Power Factor Protection & Surge ProtectionCombination units consist of both geyser controller and passive power factor (energy saving). These are parallel connection types, for single and three phase units, some available fitted with surge protection.

Code DescriptionES100-GCES100-GC-SSES100-2GC-SSES300-GCES300-GC-SSES300-2GC-SS

Single phase power + Geyser controllerSingle phase power + Geyser + Surge protectionSingle phase power + 2 x Geyser + Surge protectionThree phase power + Geyser controllerThree phase power + Geyser + Surge protection (3ph+N)Three phase power + 2 x Geyser + Surge protection (3ph+N)

Technical InfoSingle-Phase voltage: 220-240VAC 50HzThree-Phase voltage: 380-420VACSurge Protection: 65kA

MS15

ES100

ES300

Dimensions 95 x 56 x 56125 x 85 x 60190 x 140 x 70D240 x 190 x 90D240 x 190 x 90D

Dimensions170 x 200 x 85mm170 x 200 x 85mm170 x 200 x 85mm210 x 215 x 100mm210 x 215 x 100mm210 x 215 x 100mm

(3 Phase) Monitoring System*Add 2 x Current Sensor (AML-CS) + AML-1208CodeAML-CS

Kit Description

DescriptionCurrent Sensor

The three-phase energy saver can be wired either at the DB or the incoming Eskom box.Note: As long as the black is connected to neutral, it does not matter which of the other wires connect to which phase.

Eco-F

rien

dly

183

INST

RU

MEN

TS

Page 8: ACDC Pages 177-192 (low res).pdf

Type CodeTotem Pole Output (HTL)NPN N/O Output (TTL)Line Driver Output (TTL)Pulses/Revolution

Supply VoltsE40S6-*-3-1E40S6-*-3-2E40S6-*-6-L

12-24VDC12-24VDC5VDC

*Add to code: *100, 360, 500, 1000,1024

Code Supply VoltsE50S8-*-3-1E50S8-*-3-2E50S8-*-6-L

12-24VDC12-24VDC5VDC

*Add to code: *50, 100, 200, 250, 360, 1000, 1024, 1800, 2500, 3600

40mmØ, Shaft type encoder(Incremental Type)

50mmØ, Shaft type encoder(Incremental Type)

Shaft

Totem Pole OutputNPN Open OutputLine Driver Output

Max. Response Freq.

Specifications 6mm 8mm

Low Load current: Max. 30mA, Residual voltage: Max. 0.4VHigh Load current: Max. 10mA, Output Voltage: Min. 1.5V

Load Voltage: Max. 30V, Load current: Max. 30mA, Residual Voltage: Max. 0.4VLow Load current: Max. 20mA, Residual Voltage: Max. 0.5VHigh Load current: Max. -20mA, Output Voltage: Min. 2.5V

180kHz

Code E4DC-6/6Code E5DC-8/8

Coupling

Code E5DC-10/10

Manual Start/StopFuel and Start solenoid

Common AlarmLow oil Pressure

High Engine Temp.Auxiliary Shutdown

Charge Fail

None

None

NoneNone

First Up Fault*Low oil Pressure

*High Engine Temp.*Charge fail warning*Auxiliary shutdown

68 x 68None

ApplicationRelay outputs

Digital inputs

Analog inputs

Config. Method Event logging*Comms. Port RS232 or RS485

Operator Display

Other Feautres

Panel CutoutCANbus

Code DSE501K-1

GENSET CONTROLLERS

AMFFuel on, Crank

2 x Configurable

Low oil PressureHigh Engine Temp.Auxiliary Shutdown

+2 ConfigurableNone

Via front face

NoneNone

Warning/Shutdown &active inputs are

signalled by LEDs, load transfer (contactor control) have a mimic

LED display

149 x 109None

704AMF

Fuel, Crank, Mains & Alt Contactor

2 x ConfigurableLow oil Pressure

High Engine Temp.Auxiliary Shutdown

+2 ConfigurableNone

Via front face

NoneNone

Hour counter + warning/shutdown & active

inputs are signalled by LED's Load transfer,

(contactor control) have a mimic LED display

154 x 98None

4120AMF

Fuel, Crank, Mains & Alt Contactor

2 x ConfigurableLow Oil Pressure, High Engine Temp,

Emergency Stop, Remote Start (3 attempt) or Mains Stimulation,

Charge Fail (D+) 2 Configurable2 Inputs. Coolant temp. & oil pressure with the option of

configuring these as digital inputsFront face or PC via interface

type P810NoneNone

Backlit LCD scrolling Mains - Alternator voltage. Load Current,

Oil Pressure, Engine Temperature, DC Volts, Hours Run, RPM and

Hz, Alternator or Mains info, Common Alarm and Scroll Button.

Mimic LEDs, Mode Selection

182 x 137None

DSE720AMF

Standard Gen Controller Outputs

+ 4 x fully ConfigurableStandard Gen Controller

Inputs+ 8 fully Configurable

4 including pressure, temperature and fuel volume

Limited front face, Fully via USB programming port250 most recent events

Type of events recorded can be selected. Fitted with both RS232 and RS485, but only one can be used at a time

Multi Menu Access via front panel: Status, Engine,

Generator, Mains, Alarms, Event log, Serial Port

• Modbus RTU • IP65 gasket • USB connectivity & SCADA• Engine exercise Schedular • Dummy load control plus

load shedding up to 5 stages220 x 160CANbus

DSE7320

All controllers are suitable for 12 or 24V DC systems.*For remote real time diagnostics and telemetry, including SMS communications. PSTN or GSM modem not included.

Code P810 INTERFACEUSB Interface Module c/w cables and software for programming Model 720

ROTARY ENCODER

DPM

INST

RU

MEN

TS

184

Page 9: ACDC Pages 177-192 (low res).pdf

72 x 72YY2NN YNNN

L1/NL-L-N

NNNNNN N

LEDYYNNYY

96 x 96YY21N YYNN

L1/NL-L-N

NNYYYN N

LEDYYNNYY

144 x 204 x 37 YY21N YYNN

L1/NL-L-N

NNYYYN N

LEDYYNNYY

144 x 204 x 37 YY64Y YYYY

L-L-NL-L-N

YYYYYY

Last 50 eventsLCD

YYYYYY

144 x 204 x 37 YY64N YYYY

L-L-NL-L-N

YYYYYY

Last 32 eventsLED

YYYYYY

Size (mm)Automatic engine start/stop and load transferManual, Automatic and Test Mode controlUser configurable inputsUser configurable outputsOptional expansion board with user configurable 8 I/O EXOM-210.FL.EXRSpeed sensing from alternator voltageSpeed sensing from magnetic pickup3 resistive sender inputs (oil, fuel, temp.)Load current measurementGenerator Volts measurementMains Volts measurementEarth current measurementExercise at programmed time intervalsRS-232, Modbus ASCII Serial communicationAvailable for Remote using by PC softwareStandard modem communicationGenerator Power measuring by kVA, kW, kVAh, kWh, kVAr, kWrhEvent logsDisplayMains contactor outputsGenerator contactor outputsProgrammable weekly working permit calendarMaintenance warning (working hour or elapsed month)Fully ProgrammableSimple push button controlled operation

Model EAOM-19 EAOM-09 EAOM-09F EAOM -210FLS EAOM-210FDS

YY

Frequency Measurement

NYN21YN YYN

LED72 x 72

YY

Generator Voltage/ Power Measurement

3 PhaseYN32YY YYY

LED96 x 96

YY

Generator Voltage/ Power Measurement

1 PhaseYY32YY YYY

LED96 x 96

Automatic engine Start/StopAutomatic Shutdown on fault conditionAlternator voltage and fre-quency measurementLoad current measurementRemote Start/Stop input3 resistive sender unitsUser configurable inputsUser configurable outputsSpeed sensing off AlternatorSpeed sensing off magnetic PickupRS-232 Serial CommsRemote use from PCStandard Modem CommsDisplaySize (mm)

Model EAOM-36 EAOM-7 EAOM-71

144 x 204 x 37 YY64N YYYY

L-L-NL-L-N

YYYYYY

Last 32 eventsLCD

YYYYYY

MESSENGER

EAOM-19 EAOM-9 EAOM-9F EAOM-210FLS EAOM-2FDS MESSENGERwith GSM

ATS-10 EAOM-3ControlsGenerator remote startLoad transfer to mainsMains and generator contactorMonitors3 Phase mains voltageAlternator voltageProgram parameters

Size: 72 x 72mm

ControlsFuel and stop solenoidStarter motorManual generator start/ stopPreheat (Glow Plug)MonitorsEngine running timeError IndicationFail MonitoringLow oil pressureHigh temperatureOver speed failureCharging fail

Size: 72 x 72mm

Automatic Transfer Switch

Manual Key Start Controller

DPM

GENSET CONTROLLERS 8-32 VDC

185

INST

RU

MEN

TS

Page 10: ACDC Pages 177-192 (low res).pdf

• Climatic category: 25/85/21.• Standard tolerance: ±5%; -2+8%.• Rated frequency: 50 – 60Hz.• Voltage: 1.1 Un at 50Hz.• Dissipation factor at 20°C, V = Un, 50Hz: ≤15:10-4

Specifications• Dielectric material: Metalised polypropylene, low losses non inductive winding.• Case and cover: self-extinguishing thermoplastic resin.• Lead: 2 x 0.75mm2. PVC 90°C.• Reference standards: CEI 33-3; VDE 560-8; ASE 1029; VDE EN60252.

Code Capacitance(µF)

SizeØ x H mm

CA-2MFCA-2.5MFCA-3MFCA-3.5MFCA-4MFCA-4.5MFCA-5MFCA-6MFCA-6.3MFCA-7MFCA-7.5MFCA-8MFCA-9MFCA-10MFCA-11MFCA-12MF

22.533.544.5566.377.589101112

25 x 5325 x 5325 x 5325 x 5325 x 5325 x 5325 x 6925 x 6925 x 6925 x 6930 x 7330 x 7330 x 7330 x 7330 x 7335 x 73

Code Capacitance(µF)

SizeØ x H mm

CA-13MFCA-13.5MFCA-14MFCA-15MFCA-16MFCA-17.5MFCA-18MFCA-20MFCA-25MFCA-30MFCA-32MFCA-35MFCA-40MFCA-45MFCA-50MFCA-55MFCA-60MF

1313.514151617.51820253032354045505560

35 x 7335 x 7335 x 7335 x 7335 x 7335 x 7335 x 7335 x 9635 x 9640 x 9540 x 9540 x 9550 x 10050 x 10050 x 10050 x 10050 x 100

MOTOR STARTING & LIGHTING CAPACITORS

Code Capacitance(µF)

SizeØ x H mm Code Capacitance

(µF)

Motor Run Capacitors – 480VAC Motor Start Capacitors – 275VAC

CAR-1.5MFCAR-2MFCAR-3MFCAR-4MFCAR-5MFCAR-6MFCAR-8MFCAR-10MFCAR-12MFCAR-14MFCAR-16MFCAR-18MFCAR-20MFCAR-25MFCAR-30MFCAR-40MFCAR-50MF

1.523456810121416182025304050

25 x 5525 x 5530 x 6332 x 7332 x 7332 x 7332 x 7332 x 7335 x 7535 x 7535 x 7535 x 9835 x 9835 x 9840 x 9450 x 10050 x 100

CAS-30MFCAS-50MFCAS-100MFCAS-125MFCAS-130MFCAS-160MFCAS-300MFCAS-328MF

30 - 3653 - 6488 - 106124 - 149130 - 156145 - 174270 - 324328 - 454

SizeØ x H mm50 x 8550 x 8550 x 8550 x 8550 x 8550 x 8550 x 11060 x 110

Supplied with 150mm flying leads and M8 mounting stud

Lighting Capacitors – 250VAC

With mounting stud M8

T

CA

PAC

ITO

RS

& P

FC

186

Page 11: ACDC Pages 177-192 (low res).pdf

R0440-050R0440-075R0440-100R0440-125R0440-150R0440-200R0440-250R0440-300R0440-350R0440-400R0440-450R0440-500R0440-600R0440-700R0440-800

440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V

57.51012.51520253035404550607080

6.5A9.7A13A16A20A26A33A40A46A52A58A66A79A92A105A

300 x 115 x 115300 x 115 x 115300 x 115 x 115300 x 115 x 115300 x 115 x 115425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 165 x 150425 x 320 x 150425 x 320 x 150425 x 320 x 150

Code Rated Voltage 440V

468.510.51317222629353844526070

400VCurrentper Phase

DimensionsH x A x P(mm)

Code Ø x Hmm

C440-010C440-015C440-020C440-025C440-030C440-040C440-050C440-075C440-100C440-125C440-150C440-200C440-250C440-300C440-350C440-400C440-500

70 x 21570 x 21570 x 21570 x 21570 x 21570 x 21570 x 21585 x 215100 x 215100 x 215100 x 300120 x 300120 x 300136 x 300136 x 300136 x 300136 x 300

Currentper Phase1.3A1.9A2.5A3.2A3.8A5.0A6.3A9.7A13A17A20A26A33A39A46A58A66A

440VkVAr at

11.522.53457.51012.515202530354050

400V0.81.21.522.53468.510.513172226293645

Ideal for use with harmonic filters• Terminals – clamp type • Mounting via stud • Overpressure disconnection • Discharge resistors fittedManufactured to EN60831-1/2

Rated Voltage440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V440V

Cylindrical 3 phase power factor capacitors

Technical CharacteristicsCapacitance tolerance: -5 +10%Frequency: 50Hz (60Hz on request)Temperature Range: -40°c + 55°cDielectric Losses: ≤ 0.5 W/kVArMaximum over voltage: 1.11 x UnMaximum over current: 1.5 x InFuse ratings to be 1.5 to 1.8 times the nominal capacitor current

VM-60VM-70VM-90VM-100VM-120VM-150VM-180VM-210

Code Size kVAr Steps 800 x 600 x 400 800 x 600 x 400 800 x 800 x 4001115 x 800 x 4001115 x 800 x 4001575 x 600 x 4001575 x 600 x 4001838 x 600 x 400Other standard panels available: 240, 270, 300, 330, 360, 420, 480, 540, 600 and 660kVAr.Standard panels include incoming isolator, controller, protection fuses, contactors and capacitor banks.

607090100120150180210

20 + 20 + 2020 + 20 + 3010 + 20 + 30 + 3020 + 20 + 30 + 3030 + 30 + 30 + 3030 + 30 + 30 + 6030 + 30 + 60 + 6030 + 60 + 60 + 60

Automatic PFC Panels – 400V

kVAr Selection: See AC/DC Website. Energy audit service availableVM-100

kVAr at

WireSize2.5mm2

2.5mm2

2.5mm2

2.5mm2

2.5mm2

2.5mm2

2.5mm2

6mm2

6mm2

6mm2

10mm2

25mm2

25mm2

50mm2

50mm2

50mm2

50mm2

WireSize2.5mm2

4mm2

4mm2

6mm2

10mm2

10mm2

10mm2

16mm2

16mm2

25mm2

25mm2

50mm2

70mm2

70mm2

95mm2

• Maximum THD in Voltage: 2%• Maximum THD in Current: 25%• Discharge Resistance: Incorporated• Dielectric: Metalized polypropylene film• Voltage test between terminals: 2.15 x Un 2sec • Voltage test terminals to case: 3kV for 10 sec AC• Standard EN60831-1/2

Ideal for use with harmonic filters• Terminals –

stud type • Discharge

resistors fitted

Manufactured to EN60831-1/2

Code Ø x Hmm

CurrentA550V

kVAr at400V

Rated Voltage

D2800C550-75C550-100C550-125C550-150C550-200C550-250C550-300C550-400C550-500

70 x 21585 x 21585 x 215100 x 215100 x 215100 x 300120 x 300120 x 300136 x 300136 x 300

3.73A5.59A7.46A9.32A11.19A14.91A18.64A22.37A29.83A37.28A

57.51012.5152025304050

2.643.975.296.617.9310.5813.2215.8721.1526.44

550V550V550V550V550V550V550V550V550V550V

WireSize4mm2

4mm2

4mm2

4mm2

6mm2

6mm2

10mm2

10mm2

16mm2

25mm2

3 Phase Capacitors – Steel enclosed type

POWER FACTOR CORRECTION CAPACITORS

T

WARNING: all PFC systems require protection against harmonics, generated by such devices as variable speed drives and UPS’s, and transient surges including lightning.

187

CA

PAC

ITO

RS

& P

FC

Page 12: ACDC Pages 177-192 (low res).pdf

Code RG-8BS RG3-12CS ED8-96

2.557.51012.515202530

RTF-2.5RTF-5RTF-7.5RTF-10RTF-12.5RTF-15RTF-20RTF-25RTF-30

Harmonic Filters are designed to eliminate the 5th (250Hz) harmonic & higher, which can cause damage to three phase capacitors used for power factor correction.

Standards: IEC-289; IEC-076Tolerance “L”: 3%Thermostat Protection: 90°CHeat Insulation Class: Class F (155°C)Insulation Voltage: 4kVMaximum Overload: 1.17 x InMaximum THD in current: 25%Voltage: 440V, 50Hz, Resonance Frequency: 189Hz

CodePower KVAr

3540455060708090100

RTF-35RTF-40RTF-45RTF-50RTF-60RTF-70RTF-80RTF-90RTF-100

CodePower KVAr

THREE PHASE HARMONIC FILTERS

RDM6 RDM12

Last 10 conditions

Capacitor stepsAlarm outputVoltage measurement & supplyFrequencyDisplay typeSizeExternal C.T.ProgrammingRequired COSɸDisplaysRMS voltage & currentCOS ɸOutput relay stepAlarm displaysHigh/low voltageHigh/low currentUnder/over compensationOver voltage/currentUnder compensationCurrent & voltage distortionAlarm memoryTemperatureDual Target CosɸEnergy Ratio AlarmHarmonic Measurement & ProtectionRS-485 CommunicationCompensation Individual phases, separately

8✔

10-500& 230±10%45/65Hz

LED96 x 96

x/5AAuto/Man

Programmable

LED

High Only–✔

Voltage Only✔

12✔

10-300& 230±10%50/60Hz

LED144 x 144

x/5AAuto/Man

Programmable

LED

High Only–✔

Voltage Only✔

✔ (3 CTs)

81

230/400V45/65Hz

LED96 x 96

x/5AMan

Programmable

LED

61

380/415V50/60Hz

LCD96 x 96

x/5AAuto/Man

Programmable

LED

121

380/415V50/60Hz

LCD144 x 144

x/5AAuto/Man

Programmable

LED ✔

T

POWER FACTOR CONTROLLERS

CA

PAC

ITO

RS

& P

FC

188

Page 13: ACDC Pages 177-192 (low res).pdf

Code Max. kVAR

No. ofModules

Size H x W x D

Base Units IP31 Each contains incoming isolator, control fuses, controller plus terminals for external alarm and CT

LND-EVLND1LND2LND3

2562.5137.5200

351116

380 x 425 x 360 390 x 565 x 360 720 x 565 x 3601150 x 565 x 360

LND-EV Max. Steps4 Steps6 Steps6 Steps6 Steps

=

Code kVAR400V

Modular Width

Capacitor Modules – 440V Single Step – for LND1, 2 and 3 Base Units.Each complete with capacitors, contactor, fuses, neon fuse indicators and plug-in connections

JOL-025JOL-05JOL-10JOL-12.5JOL-15JOL-20JOL-25

2.551012.5152025

1111222

Code kVAR400V Steps

JOLEV-17.5JOLEV-20JOLEV-25

17.52025

2.5+5+105+5+105+10+10

*Modular Width333

*Effective value at 400V

*kVAR440V2.14.18.210.312.316.420.5

*kVAR440V14.416.420.5

This compact modular system is both rugged and highly efficient. By ordering a base unit, the steps required plus an external CT,a complete automatic PFC system can be assembled in minutes for fast installation. The components can be stocked by PFC specialists and electrical wholesalers for immediate supply from stock. There is no need for custom engineering or workshop assembly.• Simple ordering, assembly and installation for end users and contractors.• A wide range of systems can be assembled from very few parts.

• Rugged 440V rated capacitors offer long life.• Assembly is simply slide-in, plug-in and go!

+

MountingWallWallWallFloor

3-Step Modules for LND-EV only One module completes the system with LND-EV

NominalkVAR 400V

MaxkVAR 400V

Base Unit Required

204050607580100125150165

20.54151.2557.473.882102.5123143.5164

LND-EVLND1LND1LND2LND2LND2LND2LND3LND3LND3

Free Modules0005331420

MaxkVAR 440V255062.57090100125150175200

Recommended Combinations – Many other kVAr combinations can be created to suit application requirementsModulesRequiredJOLEV-25 x 1JOL-10 x 1 + JOL-20 x 2JOL-12.5 x 1 + JOL-25 x 2JOL-20 x 1 + JOL-25 x 2JOL-15 x 1 + JOL-25 x 3JOL-25 x 4JOL-25 x 5JOL-25 x 6JOL-25 x 7JOL-25 x 8

Steps5+10+1010+20+2012.5+25+2520+25+2515+25+25+2525+25+25+2525+25+25+5025+25+50+5025+50+50+5025+25+50+50+50

• Supply & control voltage Vn, 400V• Capacitor rated voltage, 440V• Maximum over voltage during a 24hr

period – For 8hrs 484V – For 30mins 506V

– For 5mins 528V – For 1min 570V

• Maximum over current 1.3 x In• Maximum current distortion (TDHI)

– Peak 40% – Continuous 10%

• Ambient -15 to +35°C• Operating temperature

– Peak 55°C – Maximum 24hr average 45°C – Maximum yearly average Deg., 35°C

• Loss <0.4W/kVAr

• Life expectation is 30 000hrs x (25 ÷ D)

• Standards: IEC 60439-1, IEC 60831-1

Specifications

LND1

LND2 LND3

For external CTs, see page 167. For harmonic filters, see page 188.

T

MODULAR POWER FACTOR CORRECTION SYSTEM

189

CA

PAC

ITO

RS

& P

FC

Page 14: ACDC Pages 177-192 (low res).pdf

Features• 2 x 7 digit LED displays:

PV (Process Value) REDSV1 (Set Point Value) GREEN

• Measure range: multi-range and pre-scalable• Input types: TC (J, K, R, S, T,...)

RTD (PT100...) 0-10V, 1-5V, 4-20mA

Connection Diagram for TZN4M

• SV2 input for oven door interlock• Indicating accuracy of ±0.3% ( F - S)• Dual PID function selectable fast response

PID action (PIDF) or slow response PID action (PIDS)

• Control: ON/OFF, P, PI, PD, PIDF, PIDS con-trol

SpecificationMulti-volt Supply: 100 to 240VACConsumption: 5VAControl Relay output: C/O 3A @ 250VACSampling time: 250ms

Universal 4 digit temperature controller – Dual indication (full PID controller)

48 x 48TZ4ST-14RTZ4ST-14CTZN4S-24R

72 x 72 / 96 x 96TZN4M-14R TZ4L-14RTZN4M-14C TZ4L-14CTZN4M-24R –

96 x 48TZ4H-14RTZ4H-14C

48 x 96TZ4W-14RTZ4W-14CTZ4W-24R

Size (H x W)Control Relay & Alarm Relay4-20mA output & Alarm RelayControl Relay + 2 Alarm Relays

IndicatorType Indicator 5 Sensor Input Indicator Indicator

Size

Supply Volts

Code: PT100Code: JCode: K

Temperature Range

72 x 72mm 96 X 96mm

110-230VAC

SG-781*P SG-681*P SG-781*J SG-681*J SG-781*K SG-681*K

*Add temp range100, 200, 400°C

48 x 96mm

110-240VAC

T4WM-400PT4WM-500J

T4WM-1200K

36 x 72mm

100-240VAC

T4YI-400PT4YI-500J

T4YI-1200K

24 x 48mm

12-24VDC

T3NI-400P––

Connection Diagram for TZ4H

Indicator

34 x 76mm

230VAC

MTR10-599PMTR10-999JMTR10-999K

Connection Diagram for TZN4SControlO/P ‘C’

PID TEMPERATURE CONTROLLERS

TEMPERATURE INDICATORS

48 x 48TZN4S-14RTZN4S-14CTZN4S-24R

TC

TEM

PER

ATU

RE

CO

NTR

OLS

190

Page 15: ACDC Pages 177-192 (low res).pdf

Technical specificationSupply: 110/220VACInput: Thermocouple K, J and PT100Accuracy: 1% of full scale

Connectiondiagram

Control: On/Off actionOutput: Relay 1C/O 5A@250V Hysteresis: 2,5% full scaleAlarm: 10% of full scale

Analog Setting Analog Setting & Deviation Display

Analog Setting & Full Scale Display

Thumbwheel Setting & Digital Display

–SG-714*SG-612*

–*Add temperature 100, 200, 400 or 600°C and Probe type PT100., J or K e.g. SG-622 400J

–SG-724*SG-622*

– – – SG-742* SG-632* – – –

800 & 1200°C

–SG-771*SG-671*

SG-771/A*/SG-671/A*

Size 96 x 48Size 72 x 72Size 96 x 96

Range & ProbeHigher Range ‘K’

ON/OFFControl

With alarm72 x 72/ 96 x 96

Connection diagram

All supplied complete with Y-50 mounting bracketSpecifications: Supply voltage 110-240VAC Hysteresis 2,5% full scale Relay output: 1 C/O @ 2A 250VACPanel-mount or 8 pin plug-in.

Reversed 8 pin P3G-08

Digital 1 Set Point

Transparent cover for 72 x 72VJ4482

Adaptor for 72 x 72 to 96 x 96VJ4458

Digital 2 Set Point Thumbwheel 1 Set Point Analog 1 Set Point

SizeProbe PT100Probe J & K

72 x 72mmVM6251 -99° to 999°CVM6392 -99° to 999°C

72 x 72mmVM6269 -99° to 999°CVM6400 -99° to 999°C

48 x 48mmTP-48*P *100, 200, 400°CTP-48*J *200, 400°C

TP-48*K *200, 400°C

48 x 48mmTR-48*P *100, 200, 400°CTR-48*J *100, 200, 400°C

TR-48*K *100, 200, 400°C

ON/OFFControl

When using 2-wire PT100 Probe, short circuit terminals 4 and 5

SupplyVolts

Connection diagram

IP54

Digital

34 x 76mmMTR11-150PTC*

–• Supply: 230VAC* C/W ProbeRange: 50-150°CSpare Probe: PTC150

For blind temperature controllers, see page 67.

SG-861*––

SG-861/A*

• Direct/Reverse PWM & Neutral zone operation

Technical specificationSupply: 24 or 230VACInput: Thermocouple K, J & PT100Accuracy: 1% of full scaleOutput: Relay C/O 8A@250V• Min/Max Alarms• Differential or Hysteresis

programmable

TC

TEMPERATURE CONTROLLERS

191

TEM

PER

ATU

RE

CO

NTR

OLS

Page 16: ACDC Pages 177-192 (low res).pdf

Code Current KW

Voltage Control for Heaters Single Phase (230V)

Three Phase (400V)

SpecificationsInput Signal: 4-20mA, 0-20mA, 1-5VDC. 0-5VDCControl System: Phase controlInsulation Resistance: 500VDC (10g ohms)

Output Voltage: 0-100%Constant- Voltage Characteristics: Output accuracy 1%Ambient Temperature: -10/50°C Humidity 90% RH belowVR1: Min V output Ads.VR2: Max V output Ads.

Benefits• Small size, saving space • High accuracy and fast response• Eliminates contactor noise • Extends heater life • High efficiency, no maintenance • Maintains stable process

temperature

SG-027SG-057

27A57A

612.5

Ultra fast Fuse30A60A

Code Current KWSG-100SG-132SG-162

100A132A162A

2229.336

Ultra fast Fuse100A160A160A

Code LoadCurrent KW

SG-325SG-350SG-375

25A50A75A

16.53349

Ultra fast Fuse25A50A75A

Code KWSG-3100SG-3130SG-3160

100A130A160A

6686105

Ultra fast Fuse100A160A160A

LoadCurrent

Connection Diagram

Thermocouples NOTE: Wire ColoursJ: White & White with Yellow Stripe

K: White & White with Red StripePT100: 2 x White, 1 x Red

Probe size 100mm x 5.0 ØCable: 1.5m

Thread size 1/4” or 1/2”Cable: 1.5m

Probe: 1/2” Thread150mm x 5.0 ØSteel Braided Cable PVC Coated

ProbeType

PT100

PT100PT100

Type JType K

TC-P/S*

TC-J/S*TC-K/S*

TC-P 100DStd 1/4” threadTC-P 200D*TC-P STEELStd ¼” threadTC-J*TC-K*

100°C

200°C400°C

400°C400°C

PVC

PVCSteel

SteelSteel

Thermo-coupleType

ScrewTypeCode

KSE-P

KSE-JKSE-K

Head TypeCode

TC-P2 CABLETC-P4 CABLE

TC-J CABLETC-K CABLE

Code

200°C PVC coated Grey400°C Steel braided

400°C Steel braided400°C Steel braided

DescriptionTempRange

400°C

400°C400°C

TempRange

CableType

Installationexample

Temperature Transmitter (2 wire)

TRT-PT100*TRT-J*TRT-K*

SpecificationOutput Signal: 4 - 20mA DCPower Supply: 12 - 40VDCAccuracy: ±0.15% F.S. (PT100) ±0.5% F.S. (J & K)

Steel Cable

PVC Cable

*Specify 1/4” or 1/2”

Com-pression Clamp

Thermocouple Connectors

FemaleFPL-PT100FPL-JFPL-K

MaleMPL-PT100MPL-JMPL-K

1/2” BrassCC-02B

1/4” BrassCC-04B

1/2” S/SteelCC-02S

1/4” S/SteelCC-04S

Code

Probe size 100mm x 5.0 ØCable: 1.5m

*Specify 1/4” or 1/2”

KEN-P

KEN-JKEN-K

Large HeadCode

TEMPERATURE PROBES

SCR HEATER ELEMENT REGULATORS

*Add Temperature range PT100: 50, 100,150, 200, 400°C J: 100,150, 200, 400, 600°C K: 100,150, 200, 400, 600, 1000, 1200°CFits into Head Type KEN-P, J or K

TC

RHE

TEM

PER

ATU

RE

CO

NTR

OLS