Accusonic Model 7700-7720 Networked Flowmeter System · in exposed or buried pipes, penstocks, ˚...
Transcript of Accusonic Model 7700-7720 Networked Flowmeter System · in exposed or buried pipes, penstocks, ˚...
Accusonic® Technologies, a division of ADS® LLC, designs and manufactures ultrasonic
transit-time � ow measurement systems that are renowned
for their precise accuracy and reliability in di� cult operating
environments. Accusonic � owmeter systems can be
found in hydroelectric plants, thermal power plants, water and wastewater treatment facilities,
sewage collection systems, and other types of water � ow
conveyance pipelines and channels. With over 35 years of experience and over 3000 systems installed worldwide,
Accusonic o� ers a full range of services including installation,
system integration, turbine performance testing services,
and � eld training.
Accusonic Model 7700-7720 Networked Flowmeter System
About AccusonicSYSTEM DESCRIPTION
C A P A B I L I T I E S S U M M A R Y
© 2008 ADS LLC. All Rights Reserved.
28 Patterson Brook Road, West Wareham, MA 02576, USA • Tel. +1- 508-273-9600 • Fax: +1- 508-273-9699 • Email: [email protected]
SYSTEM SPECIFICATIONS
H A R D W A R EH A R D W A R E
The Accusonic® Model 7700-7720™ Networked Flowmeter System o� ers 7th generation Accusonic ultrasonic transit-time � ow measurement technology for reliable, high-accuracy � ow monitoring in large pipes and open channels. The Model 7700™ Master Control Unit provides integrated � ow monitoring capability with centralized control and enhanced real-time connectivity to multiple pipes and/or channels within a single plant or network of plants. The 7700 allows for � exible con� gurations of � ow measurement networks across pressurized pipes, penstocks, low-head intakes, and open channels.
The networked � owmeter system uses the Model 7720™ Flowmeter to measure � owrates in more than one pipe or channel. The system can be expanded with additional 7720 Flowmeters to simultaneously monitor � owrates in up to 64 separate locations. Measurable pipe/channel sizes range from 8 inch (200 mm) to 500 feet (150 m) in diameter.
The Model 7720 Flowmeter utilizes the multiple parallel-path transit-time technique, an absolute � ow measurement method which is capable of achieving high accuracy under di� cult metering conditions. Flowrate is calculated in the 7720 via full-pro� le integration of the � ow velocity measured at each acoustic path. Measurement accuracies to within + or - 0.5% of true � owrate can be achieved. In addition, the 7700-7720 System can provide � ow measurements in accordance with the ASME PTC 18-2002 test code using up to 18-paths in a single pipe application.
• Continuous Flow Measurement, Recording and Data Display• Multiple Pipe Flowrates and Flow Totalization• User-Selectable Display Screens (Data & Diagnostics Displays)• Easy, Menu-Based System Setup and Operation• Automated Self-Test and Operational Diagnostics• Accusonic HydroFlowTM Software for
enhanced operation.
Model 7700-7720 Features
Power Requirement 90 - 260 VAC, 47 - 63 Hz(DC Power Options Available)
Style Options 7700DT Desktop Computer7700NB Notebook Computer7700TB Ruggedized Notebook Computer
Data display options for above: Flowrate Totalized Flow System Status Calendar / Clock Any Parameter or Variable User-De� nable Screens Velocity Pro� le
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
DS-7700-7720-10-05-08
www.accusonic.com
Model 7700 shown with Ruggedized Notebook Computer and Model 7720 Flowmeter
Model 7700 Notebook Computer with HydroFlowTM Software and Model 7720 Flowmeter
Output OptionsEthernet ConnectivityRS-232 Serial Communication PortFormatted Reports for output to printersEight (8) Isolated 4 - 20 mA Outputs – OptionalEight (8) Pulsed Totalizer / Alarm Relay Contacts – OptionalModbus Interface (RS-232 or RS-485) – Optional
Model 7720 Flowmeter speci� cations available in the Model 7720 data sheet
A Division of ADS LLCADS. An IDEX Fluid & Metering Business.
A Division of ADS LLC
H A R D W A R E
SYSTEM CONFIGURATIONS
Accusonic � owmeters may be con� gured for a wide variety of applications, including � ow measurements in exposed or buried pipes, penstocks, � ow conduits, intake structures, tunnels or open channels. Accusonic has developed specialized transducers to meet virtu-ally any installation requirement, including the follow-ing transducer options.
• Fully Removable and Fixed Window Transducers for Exposed Steel Pipes
• Internal-Mount and Array-Mount Transducers for Concrete Pipes and Conduits
• ‘Cold Tap’ or ‘Hot Tap’ Transducers for Pipes with External Access Only
• Low-Cost Transducers for Low-Head Hydro Intakes
APPLICATIONS
• Hydropower Flow Monitoring - Penstocks and Low- Head Intakes
• Pump and Generate Flow Monitoring for Pumped- Storage Plants
• Precision Flow Measurement for Turbine Effi ciency Testing (meets ASME PTC 18-2002 and IEC 60041 codes)
• Water Supply and Transmission Flow Monitoring
• Water Distribution and Revenue Metering
• Pump and Irrigation Flow Control
• FERC Minimum Flow Compliance Documentation
SYSTEM ADVANTAGES
• Multiple-Pipe Flow Measurements from a Single Console
• Superior Accuracy Over Wide-Ranging Flow Conditions
• Minimal Flowstream Intrusion, No Head Loss
• No Required ‘Flow Profi le’ Calibrations
• Bi-Directional Flow Measurement Capability
• Flexible System Outputs to Meet Engineering Requirements
• Ethernet and Modbus Interfaces for SCADA Applications
BENEFITS
• Improve and Document Hydro Unit Performance
• Ensure Unit Power Output Meets Specifi cations
• Balance Hydro Unit Allocation Dispatch
• Document Water Resource Utilization Compliance
• Improve Power Plant and Unit Effi ciency
Hyrdopower Low-Head Intakes
Multiple Pipe Monitoring with Remote7720 Flowmeters
Model 7657/7658 Internal Mount Transducers
Model 7601/7641 Feedthrough Transducers
Model 7625/7605 Fixed Window Transducers
FLOW
7700
7720
7720
7720
7700
77207720 TRANSDUCER OPTIONS