accessories - nihon kohden

101

Click here to load reader

Transcript of accessories - nihon kohden

Page 1: accessories - nihon kohden

ACCESSORIESCARDIOLOGY2 0 1 3 / 2 0 1 4

Fighting Disease with Electronics

Page 2: accessories - nihon kohden

www.nihonkohden.net2 www.nihonkohden.net2

Dear Customer,

For more than 60 years NIHON KOHDEN has been one of Japan’s leading players in medical technology development and manufacturing and has subsidiaries and representative o� ces in Europe, the US, as well as in the Middle and Far East.

“Fighting Disease with Electronics“ – our corporate philosophy – refl ects the high standards we have set ourselves in combating disease by developing medical systems, contributing to higher quality of life for patients.

Our large product range of accessories and consumables is known for its outstanding quality, ease of use and reliability. Please note, that only the use of original NIHON KOHDEN approved accessories and consumables guarantee optimal examination results and make an important contribution towards ensuring that your device will continue to function impeccably and reliably even in years to come, while preserving the device’s features and functional capabilities.

As your partner in cardiology, NIHON KOHDEN provides only tested and approved product solutions from standard vital signs parameter such as ECG, SpO2 , NIBP or Temperature to specifi c parameters like Capnography or IBP Measurement. Our commitment to ensure continually highest quality allows you the best care of your patients and enhances your ECG, AED/TRN and Defi brillator performances.

NIHON KOHDEN invites you to discover the quality and features of our complete accessories and consumables portfolio in this

catalogue. Call today for more information or order directly!

Best regards,

NIHON KOHDEN EUROPE GmbH

Kristin Baar

Product Manager Accessories & Consumables

Introduction

Introduction

Page 3: accessories - nihon kohden

www.nihonkohden.net3 www.nihonkohden.net3

Accessories & Consumables Cardiology

Content

User Guide 6

Product Innovation & Smart Cable TM Technology 7

Highest Safety and Quality Standards 8

Quick Guide Electrocardiographs, Defi brillators, AED/TRN 9

1 ECG Measurement 10

Typical Arrhythmia Waveforms 11

1.1 ECG Cables 12

1.1.11.1.21.1.31.1.4

ECG 10-Lead CableECG 12/15-Lead CableECG Veterinary 5-Lead CableAdditional Cable Accessories

13141515

1.2 ECG Electrodes 16

1.2.11.2.21.2.31.2.41.2.51.2.6

Clip Electrodes Chest & Plate ElectrodesTab ElectrodesECG Electrodes for AdultsECG Electrodes for Children, Infants & NeonatesECG Electrode Adapter

171819202121

1.4 ECG Batteries 22

1.5 ECG Paper 24

1.6 Additional ECG Accessories 27

2 Accessories for Defi brillators 30

2.1 Defi brillator Batteries & Battery Charger 31

2.2 Defi brillator Paper 33

2.3 Defi brillator Bags 35

Page 4: accessories - nihon kohden

www.nihonkohden.net4 www.nihonkohden.net4

2.4 Disposable Defi brillator Pads 37

2.4.12.4.2

Disposable Pads with NIHON KOHDEN ConnectorDisposable Pads with R2 Connector

3839

2.5 Paddle Electrodes 40

2.5.12.5.22.5.3

Internal Paddle Electrode with Discharge Button for Series TEC-8300Internal Paddle Electrode with Discharge Button for TEC-5500/7700Neonate Paddle Adapter for TEC-5500/7700

414242

2.6 ECG Measurement 43

Typical Arrhythmia Waveforms 44

2.6.1 ECG Cables 45

2.6.1.1 ECG Cables for TEC-8300 46

2.6.1.1.12.6.1.1.2

ECG 3/6-Lead CablesECG 10-Lead Cables

4748

2.6.1.2 ECG Cables for TEC-5500 & TEC-7700 49

2.6.1.2.12.6.1.2.22.6.1.2.3

ECG 3-Lead CablesECG 5-Lead CablesFurther Defi brillator Connection Cables

505152

2.7 ECG Electrodes for Defi brillators 53

2.7.12.7.2

ECG Electrodes for AdultsECG Electrodes for Children, Infants & Neonates

5455

2.8 SpO2 Measurement 56

2.8.1 SpO2 Cables 57

2.8.2 SpO2 Probes 59

2.8.2.12.8.2.22.8.2.2.12.8.2.2.22.8.2.2.32.8.2.2.4

Reusable SpO2 ProbesDisposable SpO2 ProbesDisposable SpO2 Probes 24 pcs/box - cable length: 0.8 mDisposable SpO2 Probes 24 pcs/box - cable length: 1.6 mDisposable SpO2 Probes 5 pcs/box - cable length: 0.8 mDisposable SpO2 Probes 5 pcs/box - cable length: 1.6 m

616363646466

Content

Page 5: accessories - nihon kohden

www.nihonkohden.net5 www.nihonkohden.net5

2.9 ETCO2 Measurement (Capnography) 68

ETCO2 Selection Guide 69

ETCO2 Measurement Overview 70

2.9.1 ETCO2 Mainstream 71

2.9.1.12.9.1.22.9.1.3

Intubated Expired ETCO2

Intubated Expired and Inspired ETCO2 - “Opening a New Era in Capnography“Intubated and Non-Intubated Expired ETCO2 CapOne - “Opening a New Era in Capnography“

727374

2.10 Temperature Measurement 76

2.10.12.10.2

Standard Temperature MeasurementMeasurement of 2 Additional Temperatures

7777

2.11 NIBP Measurement (Non-invasive Blood Pressure) 78

2.11.12.11.22.11.32.11.3.12.11.3.2

NIBP Air HosesReusable NIBP Cu� s - NEW YAWARA CUFF 2Disposable NIBP Cu� sDisposable NIBP Cu� s for Infants & ChildrenDisposable NIBP Cu� s for Adults

7980828283

2.12 IBP Measurement (Invasive Blood Pressure) 84

2.12.12.12.2

IBP Transducer Cable with Direct ConnectionIBP Transducer Cable with Adapter Cable K952

8586

2.13 Portable CPR 88

2.14 Additional Defi brillator Accessories 90

3 Accessories for AED & Training Unit 92

3.13.2

Accessories for AED UnitsAccessories for AED Training Unit TRN-2100K

9696

Accessory Order Form 97

Index as per Supply Code 98

Index as per Model Code 100

Content

Page 6: accessories - nihon kohden

www.nihonkohden.net6 www.nihonkohden.net6

Care of Environment NIHON KOHDEN is making every possible e� ort to ensure that the actions of the company and its employees contribute to

preserving the environment. In order to conserve paper resources, we decided a more environment friendly approach which allows

us to update the catalogue more frequently in the future. Therefore the new accessories and consumables catalogue was designed

for view on your computer. It allows you to zoom pictures in order to see more details of the product. If you need indeed certain

chapters in print version, you can easily select and print them.

Find the right accessories in the catalogue You do not know exactly which article you need for your examination?

Following this user guide you will fi nd the content of this catalogue which is organized into parameter categories. In a particular

category you will see a list of accessories and consumables with corresponding supply codes, model codes, descriptions and

pictures. If you are not sure if one of the listed products will fi t to your requirements, please contact us or one of our regional

representatives.

You already know the article that you need for your examination?

In the index of the catalogue , from page 98 to page 99, the articles are listed alphabetically as per supply code; page 100, the products are

listed alphabetically as per model code. They will help you to fi nd directly the according product page.

If you are using the PDF version, simply use the “search function” of this by entering the description, supply or model code.

Or just click on the related chapter on the left side of the document.

Order informationTo order NIHON KOHDEN accessories and consumables or to get more information, please refer to the indicated regional

NIHON KOHDEN representatives below.

For your convenience, we have a printable order form at the end of this catalogue so that you can fax in your order directly or

mail/e-mail it to us. Please make sure to fi ll out all requested information as well as the required supply code and according

quantity. Please check the general terms and conditions including delivery time, payment and general warranty with your

responsible regional NIHON KOHDEN representatives:

User Guide

For Germany, Austria, Switzerland and BeneluxNIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland Albert-Einstein-Ring 9, 14532 Kleinmachnow, DeutschlandFax: +49 (0) 33203/573-19, E-Mail: [email protected] For Spain and Portugal NIHON KOHDEN IBERICA S.L. C/Ulises, 75A, 28043 Madrid, SpainFax: +34 91 300 46 76, E-Mail: [email protected] United KingdomNIHON KOHDEN UNITED KINGDOM Ltd. Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Surrey KT6 7EL, United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]

For France NIHON KOHDEN FRANCE SARL 8, rue François Delage, 94230 Cachan, FranceFax: +33 (0) 1 49 08 93 32, E-Mail: [email protected] Italy NIHON KOHDEN ITALIA S.r.l. Via Fratelli Bronzetti, 28, 24124 Bergamo, ItalyFax: +39 (0) 35-232546, E-Mail: [email protected] For all other European Countries, Russia, Turkey and Israel NIHON KOHDEN EUROPE GmbHRai� eisenstraße 10, 61191 Rosbach v. d. H., GermanyFax: +49 (0) 6003/827-599, E-Mail: [email protected]

User Guide

Page 7: accessories - nihon kohden

www.nihonkohden.net7 www.nihonkohden.net7 Product Innovation & Smart Cable™ Technology

With NIHON KOHDEN Smart Cable Technology, you will get complete mo-dular fl exibility at a signifi cantly reduced cost and without all of the incon-venience associated with traditional modular systems. Smart CableTM technology miniaturizes circuits found in traditional modules and em-beds that circuitry into the cable. When you plug a Smart CableTM into a MULTI connector, it automatically detects the type of parameter and starts measuring.

Smart Connector Technology is available for the following parameters:

NIHON KOHDEN - Smart Cable™ Technology A Cost-E� ective Solution to Modular Monitoring

Synthesized 18-lead ECG - Identify Invisible Ischemia -A New Technology for More Informative ECG Exam

What is Synthesized ECG ?

Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R)

and back leads (V7, V8, V9). The measurement procedure is the same as the standard 12-lead ECG but more information can be obtained.

18-lead synthesized ECG is expected to be useful in detecting right side and posterior infarction.

The most common ECG exam is the standard 12-lead ECG. It is simple to measure, has low burden on the body, and observing the heart from these 12 directions provides a lot of information which has a wide range of clinical applications.

However, some areas, especially pathological change in the right ventricle and the posterior wall cannot be observed from the 12-lead ECG. In order to actually measure the right chest (V3R, V4R, V5R) and back (V7, V8, V9) areas, it is necessary to use di� erent elec-trode positions than the standard 12-lead ECG. In particular, electrodes must also be attached to the patient’s back so that normal suction cup electrodes cannot be used. Also, the pati-ent must be turned over in some cases and in an emergency it is often di� cult to use back electrodes. This complicates the exam pro-cedure. Synthesized 18-lead ECG uses the 12-lead ECG waveforms to mathematically derive the waveforms of the right chest leads (V3R, V4R, V5R) and back leads (V7, V8, V9).

Standard 12-lead ECG Synthesized 18-lead ECGSynthesized right side leads (V3R-V5R) andsynthesized back leads (V7-V9) are added

V1 V2 V3

V4

V5

V6syn-V5R

syn-V7

syn-V4R

syn-V3RV1 V2 V3

V4

V5

V6

syn-V8syn-V9

Version 08/2013; Subject to change without notice

Parameter Series TEC-8300 BSM-1700 PVM-2700 BSM-3000 BSM-6000 BSM-9100 BSM-2300

initial SW initial SW SW-V.03-30 SW V.04-12 SW V.04-12 SW-V.13-05 SW V.04-31

Flo Trac (APCO) – – – –

BISx Bispectral Index –with YJ-671P

–with YJ-671P with YJ-230P

BISx remarks – – – –via JA-69xP (DAU) via AUX port only

Dual SpO₂ (Second SpO2) – –via JA-69xP (DAU) –

IBP (Invasive Blood Pressure)only PVM-2703

CO (Cardiac Output) – – –EtCO₂ (Capnography)

with PVM-2703TEMP (Temperature) – – – –RESP (Respiration) – – – – –FiO₂ (Fraction of inspired oxygen) – – – – –

= Available – = N/A Defi brillator Patient Monitors

Current Products Older Products

Page 8: accessories - nihon kohden

www.nihonkohden.net8 www.nihonkohden.net8

Highest Safety and Quality Standards Comprehensive quality assurance systems ensure that each of the more than 4,000 NIHON KOHDEN sta� members makes his/her contribution towards development, manufacture, marketing and customer services such that maximum product quality is guaranteed.

NIHON KOHDEN is certifi ed according to ISO 9001, ISO 13485 and ISO 14001.

NIHON KOHDEN designs and manufactures medical equipment in conformity with the standards of IEC 60601-1 (Medical Electrical Equipment: General Requirements for Safety).

NIHON KOHDEN products have earned a reputation for quality and long life. One reason is that all export products and major components are manufactured in our own ISO 9001 and IEC 13485 certifi ed factories.

In 1984, NIHON KOHDEN implemented a comprehensive companywide quality system, IQC – Integrated Quality Control. Under this system, quality begins at the earliest stage of every product’s life. Our IQC applies to the entire manufacturing process, from the planning stage through product development, design, parts procurement, production, inspection, storage, sales, distribution and after-sales support. IQC also involves nearly every employee.

Our rigid test procedures are structured to exceed the provisions of the GMP, Good Manufacturing Practice, codes enforced by the US Food and Drug Administration. NIHON KOHDEN also has 130 in-house quality control inspection sta� to ensure that standards are implemented and maintained in every department of the company.

IQC extends beyond production and into sales and support at each subsidiary. This sta� is responsible for ongoing contact with customers to determine their needs and making sure that these changing requirements are refl ected in new products. Service engineers are responsible for communicating any problem that may arise in the use of NIHON KOHDEN products, and assuring the customers of NIHON KOHDEN’s commitment to their satisfaction.

In 1995, NIHON KOHDEN received ISO 9001 certifi cation, the international standard for quality systems. In addition, NIHON KOHDEN’s four manufacturing facilities in Japan are the fi rst factories in the medical equipment industry to be certifi ed by the CSA, Canadian Standards Association, under their category certifi cation system. Most products sent to North America carry the CSA label.

Quality improvement is and always has been an ongoing process for NIHON KOHDEN.

Convince yourself of our expertise and the high quality of our products and services! Order directly!

Highest Safety and Quality Standards

Page 9: accessories - nihon kohden

www.nihonkohden.net9 www.nihonkohden.net9 Quick Guide NIHON KOHDEN

ECG-2350 ECG-2550 ECG-1500/1550 ECG-1150 ECG-1250 ECG-1350

ECG-1950 ECG-9620 ECG-9320 ECG-9130/9132 ECG-9110 ECG-9020/9022

ECG-9010 ECG-8830 ECG-8820/8823 ECG-8420/8450 ECG-8350/8370 ECG-8330/8340

ECG-8240/8270 ECG-8110 ECG-6851

ELEC

TRO

CARD

IOG

RAPH

S

TEC-8321/8322/8332/ TEC-5521/5531 TEC-7721/7731 TEC-7621/7631 TEC-7511/7521/7531 TEC-7100/7200/7300 8342/8352

TEC-6100 TEC-2202/2203

DEF

IBRI

LLAT

ORS

Quick GuideElectrocardiographs, Defi brillators, AED/TRN

AED

/TRN

AED-2100 AED-2150/2151/2152 TRN-2100 TRN-2150

Page 10: accessories - nihon kohden

0

500

1000

1500

2000

2500

3000

Without ec1 With ec1

Number of false alarms

NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false

alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as

NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.

Highly accurate ec1 arrhythmia analysis

ECG Measurement

Tachy

V. Rhythm

VPC Run

VT

Ext. Tachy

VF

Page 11: accessories - nihon kohden

www.nihonkohden.net11

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Cardiology › Typical Arrhythmia Waveforms

Lead C1

C2

C3

C4

C5

C6

Typical Arrhythmia Waveforms

Heart Anatomy

Nihon Kohden products which detect arrhythmia

Electrocardiographs / Defillibrators / Bedside Monitors

Diagnostic ECG Electrode Placement Cardiac Conduction SytemR and L electrodes should be placed just below the right and left clavicle. N and F electrodes should be placed on the lower edge of the rib cage, or at the level of the umbilicus at the mid-clavicular line.

Electrode PlacementFourth intercostal space at the right border of the sternum

Fourth intercostal space at the right border of the sternum

Midway between locations C2 and C4

At the mid-clavicular line in the fifth intercostal space

At the anterior axillary line on the same horizontal level as C4

At the mid-axillary line on the same horizontal level as C4 and C5

1. Inferior vena cava2. Superior vena cava3. Right atrium4. Tricuspid valve5. Right ventricle6. Pulmonary valve7. Pulmonary artery8. Pulmonary vein9. Left atrium10. Mitral valve11. Left ventricle12. Aortic valve13. Coronary artery 14. Aorta15. Brachiocephalic artery16. Left common carotid artery17. Left subclavian artery18. Descending aorta

SA nodeThe sinoatrial (SA) node generates a wave of electrical excitation.The excitation travels through the internodal pathways to the atria and the atrial muscles contract. This is recorded as the P-wave.The excitation travels to theatrioventricular (AV) node.The excitation then travels through the bundle of His and down through the right and left bundle branches.The excitation terminates at the Purkinje fibers in the ventricles and the ventricular muscles contract. This is the depolarization and is recorded as the QRS complex.The ventricular muscles relax. This is the repolarization and is recorded as the T- wave.

1

2

3

45

6

78

9

10

1112

13

14

15 16 17

18

778

C1 C2C3

F

C4 C5C6

N

R L

1 2

2

3

4

5

5

1

2

3

4

5

6

AV node

Rightbundlebranch

Purkinjefibers

Purkinjefibers

His bundle

Ventricles

Leftbundlebranch

Atria

Premature Ventricular Contractions (PVC)

• Premature contractions • Bizarre and wide QRS complexes • Full compensatory pause • Frequent PVCs are serious

• Fast pulse rate greater than 100 bpm • 3 or more irregular beats • Needs emergency treatment and countershock • May progress to

Ventricular Tachycardia (VT)

Multi- focal PVC Ventricular Fibrillation (VF)

• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes • Needs emergency treatment and countershock

12

Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II

• Sudden absence of QRS complexes (P-waves observed) • May progress to cardiac arrest • Possibillity of Adams-Stokes syndrome • Occasionally needs pacing

P P P

• Consecutive PVCs • May progress to ventricular tachycardia

Premature Supraventricular Contractions(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)

• Narrow QRS (excluding aberrant ventriular conduction) • Ectopic focus higher than His-bundle • Non-compensatory pause

• Slight ripples on the baseline • Irregular R-R intervals • Inverted QRS complexes • Non-compensatory pause

P P

123.456

-------------

-------------

-------------------

-------------------

--------------------------

--------------------------

R-on-T PVC Third-degree (complete) atrioventricular (AV) block

• Independent development of P-waves and QRS complexes • Possibility of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing

• PVC on summit of T-wave • Bizarre and wide QRS complexes

P P P P P PP P P P P

P

Q S

T

R

Page 12: accessories - nihon kohden

ECG Cables

ECG 12/15-Lead Cable

ECG Veterinary 5-Lead Cable

Additional Cable Accessories

ECG 10-Lead Cable

Page 13: accessories - nihon kohden

www.nihonkohden.net13

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Electrocardiographs > ECG Cables

ECG 10-Lead CableSupply CodeK081

ModelBJ-902D

Description10-Lead ECG Patient Cable, 4 mm banana plug (IEC), limb 3.4 m/chest 2.9 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs

K082 BJ-903D 10-Lead ECG Patient Cable, snap (IEC), limb 3.4 m/chest 2.9 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs

K079 BJ-901D 10-Lead ECG Patient Cable, 3 mm banana plug (IEC), limb 1.2 m/chest 0.7 mFor current products: ECG-1150/1250/1350/2350Packing unit: 1 pcs

K093C BR-912D 10-Lead ECG Patient Cable, 4 mm banana plug (IEC), for input-box JC-901D, for resting ECG, limb 1.2 m/chest 0.7 mFor current products: ECG-1550Packing unit: 1 pcs

K093D BR-913D 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for resting ECG, limb 1.2 m/chest 0.7 mFor current products: ECG-1550Packing unit: 1 pcs

K093F BR-913E 10-Lead ECG Patient Cable, clip (IEC), for input-box JC-901D, for stress test, limb/chest 0.6 mFor current products: ECG-1550Packing unit: 1 pcs

K096A 490933 Connection Cable for Patient Input-Box JC-901D, cable length: 2.0 mFor current products: ECG-1550Packing unit: 1 pcs

K096B 669269 Connection Cable for Patient Input-Box JC-901D, cable length: 5.0 mFor current products: ECG-1550Packing unit: 1 pcs

Page 14: accessories - nihon kohden

www.nihonkohden.net14

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Electrocardiographs > ECG Cables

ECG 12/15-Lead CableSupply CodeK093L

ModelBR-921D

Description15-Lead ECG Patient Cable, 3 mm banana plug (IEC), for input-box JC-901D, for stress test, limb/chest 1.2 mFor current products: ECG-1550Packing unit: 1 pcs

KB010 BR-202D 12-Lead Set (Electrode Leads: R,L,F,N,C1,C2,C3,C4,C5,C6), 4 mm banana plugFor current products: ECG-2550Packing unit: 1 pcs

KB012 BR-202D XYZ-Lead Set, 4 mm banana plugFor current products: ECG-2550Packing unit: 1 pcs

K118 Slide Clipper for ChestFor current products: ECG-2550Packing unit: 1 pcs

K119 Slide Clipper for LimbFor current products: ECG-2550Packing unit: 1 pcs

Supply Code Model Chest Lead Label Color Cable Length Cable Color For current products

Packing unit

KB01A BR-202D C1 redKB02A BR-202D C2 yellowKB03A BR-202D C3 greenKB04A BR-202D C4 brownKB05A BR-202D C5 blackKB06A BR-202D C6 violetKB07A BR-202D CX1KB08A BR-202D CX2KB09A BR-202D CX3KB10C red KB11C yellowKB12D green 1.4 mKB13B

1.0 mKB13D 1.4 mKB14B yellowKB15B redKB16B blueKB17B orangeKB18B brownKB19C white 1.2 m

white

white

ECG-2550

0.7 m

grey1.2 m

1.0 m white

1 pcs

black

Page 15: accessories - nihon kohden

www.nihonkohden.net15

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Electrocardiographs > ECG Cables

ECG Veterinary 5-Lead CableSupply Code K098

Model BJ-904D

Description 5-Lead Veterinary ECG Connection Cable, 3 mm banana plug (IEC) For current products: ECG-1950Packing unit: 1 pcs

Additional Cable AccessoriesSupply Code K097

ModelBM-901D

Description Adapter for ECG Vacuum Equipment with 15 PIN Sub-D Connector to input-box JC-901DFor current products: ECG-1500/1550Packing unit: 1 pcs

Page 16: accessories - nihon kohden

It is important to prepare the skin before attaching the electrodes

by cleaning it and removing chest hair. After this please attach

the lead wire to the electrodes before placing them on the skin.

This avoids pain to the patient. Secure the lead wire to the skin

(stress loop) preventing moving of the lead wire and therefore

noise on the ECG signal.

Standard Electrodes Placements

ECG Electrodes

Three electrodes Ten electrodes

Chest & Plate Electrodes

Tab Electrodes

Clip Electrodes

ECG Electrodes for Adults,Children, Infants & Neonates

ECG Electrode Adapter

Page 17: accessories - nihon kohden

www.nihonkohden.net17

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

FactsThe NIHON KOHDEN Fastclip ECG Electrodes allow a fl exible application for routine work and emergency on every paediatric and adult patient thanks to a simple adjustability of the clip pressure (clip size). A more comfortable handling is guaranteed due to di� erent con-nectors for any existing adapter type, a big contact area for reliable ECG measurements and easier cleaning after the measurement because of less asperity of the clip. In addition to this IEC colored label sets are delivered with NIHON KOHDEN Fastclip ECG Electrodes.

By following the next steps, optimized derivations can be realized with NIHON KOHDEN Fastclip ECG Electrodes:

1.) Clean the according skin areas with alcohol in order to remove traces of dirt and oil on the skin.2.) Apply a thin layer of CardioCream F010 on the cleaned skin areas and on the electrode part.3.) Clip the electrode on the wrist or ankle. Adjust the electrode positon by sliding the electrode part according to the thickness of the limb.

Supply Code H068A

Description Fastclip ECG Electrode, 3 mm, child/adult, blue, adjustable sizeFor current products: all ECG/EEGPacking unit: 4 pcs

H068B Fastclip ECG Electrode, 4 mm, child/adult, blue, adjustable sizeFor current products: all ECG/EEGPacking unit: 4 pcs

H072 Veterinary Clip Electrode, 3 mm, cable length: 0.3 m, for K098For current products: ECG-1950/9022Packing unit: 5 pcs

Any of tip, clip and snap type connector is available. Less asperity easy cleaning.

Three types of connectors available Easy cleaning

Opens more widly*, and roundform brings easy to grip. (*compared to the previous model)

Easy to handle

Contact pressure and position of elec-trodes section can be adjusted accor-ding to patients΄ conditions.

Adjustability

Tip SnapClipPrevious model New model

Raised dotsTrench shape

strongmiddle

weak

spring

wide

narrow

Electrocardiographs > ECG Electrodes

Clip Electrodes

Page 18: accessories - nihon kohden

www.nihonkohden.net18

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Chest & Plate ElectrodesSupply Code H041A

Model 6144-000427

Description Chest Suction Electrode, 3 mm, adult, size: 20 mm dia, grey rubber ballPacking unit: 3 pcs

H043A 6144-011852 Chest Suction Electrode, 4 mm, adult, size: 20 mm dia, grey rubber ballPacking unit: 3 pcs

H044A NC-124D Chest Suction Electrode Tako, 4 mm, child, size: 14 mm dia, pink octopus rubber ballPacking unit: 3 pcs

H044B NC-124D Chest Suction Electrode Kuma, 4 mm, child, size: 14 mm dia, blue bear rubber ball Packing unit: 3 pcs

H049 Grey Rubber Ball Set for Adult Suction Electrode H043APacking unit: 3 pcs

H052A Pink Octopus Rubber Ball Set for Children Suction Electrode H044APacking unit: 3 pcs

H052B Blue Bear Rubber Ball Set for Children Suction Electrode H044BPacking unit: 3 pcs

Electrocardiographs > ECG Electrodes

Page 19: accessories - nihon kohden

www.nihonkohden.net19

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Supply Code NKD-Z715

Description Plate Electrode, adult, size: 30 mm dia, suitable limb electrode straps, for NKD-Z722 Packing unit: 1 pcs

NKD-Z722 Rubber Strap, chest, size: 135 cm x 7 cm, black, 5 rows of holes, for plate electrode NKD-Z715Packing unit: 1 pcs

NKD-Z723 Attachment Button for Rubber Strap NKD-Z722Packing unit: 1 pcs

Tab ElectrodesSupply Code NKD-ECG/TAB1

Description ECG Tab Electrode Normal, Ag/AgCl, child/adult, radiolucent (X-ray, MRI), size: 26 x 34 mm, bio-solid gel, backing material: graphite, for resting ECGPacking unit: 500 pcs

NKD-ECG/TAB2 ECG Tab Electrode Small, Ag/AgCl, child, radiolucent (X-ray, MRI), size: 13 x 34 mm, bio-solid gel, backing material: graphite, for resting ECGPacking unit: 500 pcs

NKD-H/ADAPTER2 ECG Tab Electrode Clamps for NKD-ECG/TAB1 & NKD-ECG/TAB2, 4 mm banana plugPacking unit: 10 pcs

Electrocardiographs > ECG Electrodes

Page 20: accessories - nihon kohden

www.nihonkohden.net20

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

ECG Electrodes for AdultsNIHON KOHDEN VITRODE Disposable ECG Electrodes –

The result of over 30 years experience in disposable electrode manufacturing.

The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an extended period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause “noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is to change these electrodes at least every 48 hours. Please contact us for individual offer based on your annual volume! Use the possibility of call orders!

Supply Code G203

ModelL-150

Description ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel, general usePacking unit: 5 x 30 pcs

G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony softcloth with an elastic quality for tension, solid gelPacking unit: 5 x 30 pcs

G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam tape, solid gelPacking unit: 5 x 30 pcs

G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs

G236 M-150 ECG Electrode Vitrode M, Ag/AgCl, child/adult, size: 40 mm dia, foam tape, highbrid gel, for stress testPacking unit: 5 x 30 pcs

G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent adhesion even on sweaty skinPacking unit: 5 x 30 pcs

Electrocardiographs > ECG Electrodes

Page 21: accessories - nihon kohden

www.nihonkohden.net21

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

ECG Electrodes for Children, Infants & NeonatesSupply Code G210C

ModelF-150S

Description ECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs

ECG Electrode AdapterSupply Code N-00

Description Snap Adapter for Disposable ECG Electrodes, 4 mm dia plug to clip connectorPacking unit: 5 pcs

N-08 Clip Adapter for Disposable ECG Electrodes, 4 mm dia plug to snap connectorPacking unit: 10 pcs

Electrocardiographs > ECG Electrodes

Page 22: accessories - nihon kohden

ECG Batteries

Page 23: accessories - nihon kohden

www.nihonkohden.net23

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

ECG BatteriesSupply Code X065

Model NKB-301V

Description Battery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1350/2350/TEC-5500/7700Packing unit: 1 pcs

X071 SB-901D Battery Pack, 12V, 1950 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1150/1250/1950Packing unit: 1 pcs

X073 SB-150D Battery Pack, 12V, 3600 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-1500/1550Packing unit: 1 pcs

X078 SB-201D Battery Pack, 14.4V, 3400 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: ECG-2550Packing unit: 1 pcs

X040 LCS-2012NK Battery Pack, 12V, 2000 mAh, lead-acid, rechargeableFor old products: ECG-6000/OEC-8110Packing unit: 1 pcs

X041A LCT-1912ANK Battery Pack, 12V, 1900 mAh, lead-acid, rechargeableFor old products: ECG-9022/9132Packing unit: 1 pcs

X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeableFor old products: ECG-9320/TEC-7500Packing unit: 1 pcs

Electrocardiographs > ECG Batteries

Page 24: accessories - nihon kohden

ECG Paper

Page 25: accessories - nihon kohden

www.nihonkohden.net25

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

ECG PaperSupply Code A052

Model FQW210-10-295

Description Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages, with queue mark/perforationFor old products: ECG-9320Packing unit: 10 pcs

A053 FQW210-30-295 Thermal Paper, Z-fold, 210 mm x 300 m (page 295 mm), 1017 pages, without grid, with queue mark/perforationFor current products: ECG-2550/1550 | For old products: ECG-9320Packing unit: 1 pcs

A128 RQS50-3 Thermal Paper, roll, 50 mm x 30 m, orange gridFor current products: TEC-8300For old products: ECG-6651/TEC-7100/7200/7300Packing unit: 10 pcs

A129 RQS63-3 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforationFor old products: ECG-1150Packing unit: 10 pcs

NKD-210-10/295 Thermal Paper, Z-fold, 210 mm x 100 m (page 295 mm), 339 pages, without grid, with queue mark/perforation, equivalent to A052 & NKD-210-10AFor old products: ECG-9320/old MEBPacking unit: 10 pcs

NKD-210-5-295 Thermal Paper, Z-fold, 210 mm x 50 m (page 295 mm), 169 pages, without grid, equivalent to A053For current products: ECG-2550/1550 | For old products: ECG-9320 Packing unit: 10 pcs

NKD-A054 Thermal Paper, Z-fold, 210 mm x 30 m (page 140 mm), 214 pages, without grid, with queue mark/perforationFor current products: ECG-1350/2350 | For old products: ECG-9132Packing unit: 10 pcs

NKD-A730 Thermal Paper, Z-fold, 110 mm x 20 m (page 140 mm), 143 pages, without grid, with queue mark/perforationFor current products: ECG-1250/1950 | For old products: ECG-9022Packing unit: 10 pcs

Electrocardiographs > ECG Paper

Page 26: accessories - nihon kohden

www.nihonkohden.net26

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Supply Code NKD-63

Description Thermal Paper, Z-fold, 63 mm x 30 m (page 75 mm), 400 pages, with grid, without queue mark/perforationFor old products: ECG-9620Packing unit: 10 pcs

NKD-A129 Thermal Paper, roll, 63 mm x 30 m, with grid, without queue mark/perforation, equivalent to A129For current products: ECG-1150 | For old products: ECG-9620Packing unit: 10 pcs

NKD-145-2,5 Thermal Paper, Z-fold, 145 mm x 25 m (page 100 mm), 85 pages, orange grid, equivalent to A036BFor old products: ECG-8400Packing unit: 10 pcs

NKD-145-6A300 Thermal Paper, roll, 145 mm x 60 m (page 300 mm), 200 pages, orange grid, equivalent to A132 but without queue mark/perforationFor old products: ECG-8821Packing unit: 10 pcs

NKD-A134A Thermal Paper, roll, 210 mm x 30 m, without grid/queue mark/perforationFor old products: ECG-9110/9130/9132Packing unit: 10 pcs

Electrocardiographs > ECG Paper

Page 27: accessories - nihon kohden

Additional ECG Accessories

Page 28: accessories - nihon kohden

www.nihonkohden.net28

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Additional ECG AccessoriesSupply Code F010

Model Z-101BC

Description “CardioCream” ECG Electrode Paste, 100 g tubePacking unit: 2 pcs

NKD-G711 Electrode Spray Gyrolux, skin preparation for use of suction vacuum pumps, 250 ml bottlePacking unit: 1 pcs

NKD-SD1GB Memory SD Card 1 GBPacking unit: 1 pcs

Y011 404617 Thermal Head Cleaner PenFor current products: all ECG/TEC/old MEB/EEG/allBSM/PVM/OPV/WEPPacking unit: 1 pcs

NKD-BAG Carrying Bag for ECG & AccessoriesFor current products: ECG-1150/1250/1350/1950/2350Packing unit: 1 pcs

NKD-L936 Power Cable, Schuko plug, cable length: 2.0 mPacking unit: 1 pcs

NKD-POWERLINE Multiple Power Socket (4 slots), medical certifi cationPacking unit: 1 pcs

Electrocardiographs > Additional ECG Accessories

Page 29: accessories - nihon kohden

www.nihonkohden.net29

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Supply Code K117A

Description Connection Cable for Input Box, cable length: 2.0 mFor current products: ECG-2550Packing unit: 1 pcs

K117B Connection Cable for Input Box, cable length: 5.0 mFor current products: ECG-2550Packing unit: 1 pcs

K117C Connection Cable for Input Box, cable length: 10.0 mFor current products: ECG-2550Packing unit: 1 pcs

Electrocardiographs > Additional ECG Accessories

Page 30: accessories - nihon kohden

Accessories for Defi brillators

Page 31: accessories - nihon kohden

Defi brillator Batteries & Battery Charger

Page 32: accessories - nihon kohden

www.nihonkohden.net32

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Defi brillator Batteries & Battery Charger

Defi brillator Batteries & Battery ChargerSupply CodeX065

ModelNKB-301V

DescriptionBattery Pack, 12V, 2800 mAh, nickel-metal hydride (NiMH), rechargeableFor current products: TEC-5500/7700/ECG-1350 Packing unit: 1 pcs

X077 SB-831V Battery Pack, 14.4V, 6300 mAh, lithium-ion battery, rechargeableFor current products: TEC-8300Packing unit: 1 pcs

X041 LCT-1912NK-1 Battery Pack, 12V, 1900 mAh, lead-acid, rechargeableFor old products: TEC-7100/7200Packing unit: 1 pcs

X041B LC-S2912NK Battery Pack, 12V, 2900 mAh, lead-acid, rechargeableFor old products: ECG-9320/TEC-7500Packing unit: 1 pcs

X060A NKB-102V Battery Pack, 12V, 1700 mAh, nickel-cadmium (NiCd), rechargeableFor old products: TEC-8200Packing unit: 1 pcs

SB-801V External Dual Battery Charger, for 2x battery X077For current products: TEC-8300Packing unit: 1 pcs

SC-831V AC/DC Module for Series TEC-8300KFor current products: TEC-8300Packing unit: 1 pcs

SB-551V External Dual Battery Charger, for 2x battery X065For current products: TEC-5500/7700Packing unit: 1 pcs

Page 33: accessories - nihon kohden

Defi brillator Paper

Page 34: accessories - nihon kohden

www.nihonkohden.net34

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Defi brillator Paper

Defi brillator PaperSupply CodeA128

ModelRQS50-3

DescriptionThermal Paper, roll, 50 mm x 30 m, orange gridFor current products: TEC-8300 | For old products: ECG-6651/TEC-7100/7200/7300Packing unit: 10 pcs

A222 FQS50-3-100 Thermal Paper, Z-fold, 50 mm x 30 m (page 100 mm), 300 pages, orange gridFor current products: TEC-7700Packing unit: 10 pcs

A226 FQS50-2-100 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange gridFor current products: TEC-5500/BSM-2300/3000Packing unit: 10 pcs

A238 PS50-2 Thermal Paper, roll, 50 mm x 20 m, orange grid, without queue mark/perforationFor old products: TEC-6600Packing unit: 10 pcs

NKD-A226 Thermal Paper, Z-fold, 50 mm x 20 m (page 100 mm), 200 pages, orange gridFor current products: TEC-5500Packing unit: 10 pcs

Page 35: accessories - nihon kohden

Defi brillator Bags

Page 36: accessories - nihon kohden

www.nihonkohden.net36

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Defi brillator Bags

Defi brillator BagsSupply CodeNKD-DEFIBAG83

DescriptionSoftbag for Series TEC-8300K incl. Warning Sign Label Please indicate the specifi ed abbreviation letter for the required language when ordering: English (K), German (G), French (F), Italian (R), Spanish (E), Turkish (TR) or Russian (RU)! For current products: TEC-8300Packing unit: 1 pcs

NKD-STRAP83 Shoulder Strap for Series TEC-8300K SoftbagFor current products: TEC-8300Packing unit: 1 pcs

NKD-DEFIBAG2 Carrying Bag 2 with 2 Additional Attached Accessory BagsFor current products: TEC-7700Packing unit: 1 pcs

NKD-DEFIBAG3 Carrying Bag 3 with 1 Additional Attached Accessory BagFor current products: TEC-5500Packing unit: 1 pcs

NKD-DEFIBAG6 Accessory BagFor current products: TEC-5500/7700Packing unit: 1 pcs

Page 37: accessories - nihon kohden

Disposable Defi brillator Pads

Disposable Pads with NIHON KOHDEN Connector

Disposable Pads with R2 Connector

Page 38: accessories - nihon kohden

www.nihonkohden.net38

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Disposable Defi brillator Pads

Disposable Pads with NIHON KOHDEN ConnectorSupply CodeH312

ModelP-513

DescriptionDefi brillation Pads with Outside Connector, infant (< 10 kg), for use with adapter cable JC-765V/K342B, weight: 80 g ± 10 g, size: 73 mm ± 8 mm x 110 mm ± 11 mm, conductive surface: 48.40 cm2 ± 10%, cable length: 1.5 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair

H327 P-511 Defi brillation Pads with Outside Connector, child/adult (> 10 kg), for use with adapter cable JC-765V/K342B, weight: 90 g ± 15 g, size: 108 mm ± 10 mm x 159 mm ± 10 mm, conductive surface: 99 cm2 ± 10%, cable length: 1.5 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair

K342B JC-865V Adapter Cable for Disposable Defi brillator Pads H312/H327/H324A, cable length: 3.5 mFor current products: TEC-8300Packing unit: 1 pcs

JC-765V Adapter Cable for Disposable Pads H312/H327/H324A, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

Y206A AX-250V AED Cable Testing Unit for NIHON KOHDEN-Pads with Adapter Cable JC-765V/K342BFor current products: TEC-5500/7700/8300Packing unit: 1 pcs

Page 39: accessories - nihon kohden

www.nihonkohden.net39

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Disposable Defi brillator Pads

Disposable Pads with R2 ConnectorSupply CodeNKD-H405

Model DescriptionDefi brillator Pads with Outside R2 Connector, adult, for use with adapter cable JC-755V/K342A, size: 159.93 cm², conductive surface: 114.75 cm², cable length: 1.28 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair

NKD-H406 Defi brillator Pads with Outside R2 Connector, child, for use with adapter cable JC-755V/K342A, size: 78.13 cm², conductive surface: 53.80 cm², cable length: 1.28 mFor current products: TEC-5500/7700/8300Packing unit: 1 pair

K342A JC-855V Adapter Cable for Disposable Defi brillator Pads NKD-H405/NKD-H406 with R2 Connector, cable length: 3.5 mFor current products: TEC-8300Packing unit: 1 pcs

JC-755V Adapter Cable for Disposable Defi brillator Pads NKD-H405/NKD-H406 with R2 Connector, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

Y206B AX-251V AED Cable Testing Unit for R2 Pads with Adapter Cable JC-755V/K342AFor current products: TEC-5500/7700/8300Packing unit: 1 pcs

Page 40: accessories - nihon kohden

Paddle Electrodes

Internal Paddle Electrode

Neonate Paddle Adapter

Page 41: accessories - nihon kohden

www.nihonkohden.net41

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Paddle Electrodes

Internal Paddle Electrode with Discharge Button for Series TEC-8300

Supply CodeND-893V

DescriptionInternal Paddle Electrode with Discharge Button, including handle & electrode, size: 35 mm diaFor current products: TEC-8300Packing unit: 1 pair

ND-894V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 45 mm diaFor current products: TEC-8300Packing unit: 1 pair

ND-895V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 55 mm diaFor current products: TEC-8300Packing unit: 1 pair

ND-896V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 65 mm diaFor current products: TEC-8300Packing unit: 1 pair

ND-897V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 75 mm diaFor current products: TEC-8300Packing unit: 1 pair

Page 42: accessories - nihon kohden

www.nihonkohden.net42

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Disposable Defi brillator Pads

Internal Paddle Electrode with Discharge Button for TEC-5500/7700

Supply CodeND-593V

DescriptionInternal Paddle Electrode with Discharge Button, including handle & electrode, size: 35 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

ND-594V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 45 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

ND-595V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 55 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

ND-596V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 65 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

ND-597V Internal Paddle Electrode with Discharge Button, including handle & electrode, size: 75 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

Neonate Paddle Adapter for TEC-5500/7700Supply CodeND-612V

DescriptionPaddle Adapter, neonate, size: 44 mm diaFor current products: TEC-5500/7700Packing unit: 1 pair

Page 43: accessories - nihon kohden

NIHON KOHDEN’s ec1 arrhythmia analysis provides superior elimination of false

alarms. ec1 has been evaluated with worlds standard arrhythmia databases as well as

NIHON KOHDEN’s ECG database, with a result of 80% reduction of false alarms.

Some functions are limited on series TEC-8300K. Contact your NIHON KOHDEN repre-

sentative for details.

Highly accurate ec1 arrhythmia analysis

ECG Measurement

0

500

1000

1500

2000

2500

3000

Without ec1 With ec1

Number of false alarms

Tachy

V. Rhythm

VPC Run

VT

Ext. Tachy

VF

Page 44: accessories - nihon kohden

www.nihonkohden.net44

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Lead C1

C2

C3

C4

C5

C6

Typical Arrhythmia Waveforms

Heart Anatomy

Nihon Kohden products which detect arrhythmia

Electrocardiographs / Defillibrators / Bedside Monitors

Diagnostic ECG Electrode Placement Cardiac Conduction SytemR and L electrodes should be placed just below the right and left clavicle. N and F electrodes should be placed on the lower edge of the rib cage, or at the level of the umbilicus at the mid-clavicular line.

Electrode PlacementFourth intercostal space at the right border of the sternum

Fourth intercostal space at the right border of the sternum

Midway between locations C2 and C4

At the mid-clavicular line in the fifth intercostal space

At the anterior axillary line on the same horizontal level as C4

At the mid-axillary line on the same horizontal level as C4 and C5

1. Inferior vena cava2. Superior vena cava3. Right atrium4. Tricuspid valve5. Right ventricle6. Pulmonary valve7. Pulmonary artery8. Pulmonary vein9. Left atrium10. Mitral valve11. Left ventricle12. Aortic valve13. Coronary artery 14. Aorta15. Brachiocephalic artery16. Left common carotid artery17. Left subclavian artery18. Descending aorta

SA nodeThe sinoatrial (SA) node generates a wave of electrical excitation.The excitation travels through the internodal pathways to the atria and the atrial muscles contract. This is recorded as the P-wave.The excitation travels to theatrioventricular (AV) node.The excitation then travels through the bundle of His and down through the right and left bundle branches.The excitation terminates at the Purkinje fibers in the ventricles and the ventricular muscles contract. This is the depolarization and is recorded as the QRS complex.The ventricular muscles relax. This is the repolarization and is recorded as the T- wave.

1

2

3

45

6

78

9

10

1112

13

14

15 16 17

18

778

C1 C2C3

F

C4 C5C6

N

R L

1 2

2

3

4

5

5

1

2

3

4

5

6

AV node

Rightbundlebranch

Purkinjefibers

Purkinjefibers

His bundle

Ventricles

Leftbundlebranch

Atria

Premature Ventricular Contractions (PVC)

• Premature contractions • Bizarre and wide QRS complexes • Full compensatory pause • Frequent PVCs are serious

• Fast pulse rate greater than 100 bpm • 3 or more irregular beats • Needs emergency treatment and countershock • May progress to

Ventricular Tachycardia (VT)

Multi- focal PVC Ventricular Fibrillation (VF)

• Multi form PVCs • Bizarre and wide QRS complexes • No discernable P-waves, R-waves, P-R rythm or QRS complexes • Needs emergency treatment and countershock

12

Short run PVC Second-degree atrioventricular (AV) block, Mobitz type II

• Sudden absence of QRS complexes (P-waves observed) • May progress to cardiac arrest • Possibillity of Adams-Stokes syndrome • Occasionally needs pacing

P P P

• Consecutive PVCs • May progress to ventricular tachycardia

Premature Supraventricular Contractions(Premature Atrial Contractions (PAC)) Atrial Fibrillation (AF)

• Narrow QRS (excluding aberrant ventriular conduction) • Ectopic focus higher than His-bundle • Non-compensatory pause

• Slight ripples on the baseline • Irregular R-R intervals • Inverted QRS complexes • Non-compensatory pause

P P

123.456

-------------

-------------

-------------------

-------------------

--------------------------

--------------------------

R-on-T PVC Third-degree (complete) atrioventricular (AV) block

• Independent development of P-waves and QRS complexes • Possibility of bradycardia • Possibility of Adams-Stokes syndrome • Needs pacing

• PVC on summit of T-wave • Bizarre and wide QRS complexes

P P P P P PP P P P P

P

Q S

T

R

Cardiology › Typical Arrhythmia Waveforms

Page 45: accessories - nihon kohden

ECG Cables

Page 46: accessories - nihon kohden

ECG Cables for TEC-8300

ECG 3/6-Lead Cables

ECG 10-Lead Cables

Page 47: accessories - nihon kohden

www.nihonkohden.net47

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

ECG 3/6-Lead Cables

V4V4 V5

6-lead ECG measurementPowerful ECG measurement96 % of an ischaemia change can be detected by 6 electrodes (II, V4, V5)

ST Change Detection Report• Only with I lead symbol 33%• Only with V5 lead symbol 75%

• II + V5 lead symbol 80%• II + V5 + V4 lead symbol 96%More accurate ischaemia detection

Supply Code6124-039432

Model DescriptionConnection Cable Cover for DIN Type Electrodes for K922For current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG;ZM-920/930/940PGPacking unit: 1 pcs

K120 NA-0003 Electrode Lead Tube for K911/K910AFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 5 pcs

K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 m TEC-55/7700: for connection to defi brillators L153 is required BSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 mTEC-55/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-8300/5500/7700/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

K913A BR-906V 6-Lead ECG Electrode Cable, clip, cable length: 0.6 mFor current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

K912 BR-906P 6-Lead ECG Electrode Cable, clip, cable length: 0.8m requires K922For current products: TEC-8300/all BSM/PVM; ZM-920/930/940PGPacking unit: 1 pcs

Page 48: accessories - nihon kohden

www.nihonkohden.net48

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

Supply CodeK915

ModelBR-916P

Description6-Lead ECG Electrode Cable, snap, cable length: 0.8m,requires K922For current products: all BSM/PVM/TEC-8300; ZM-920/930/940PGPacking unit: 1 pcs

K922 JC-906P 3/6-Lead ECG Connection Cable for K910A/K911/K912/K915 to patient monitors/defi brillator, cable length: 3.0 mFor current products: TEC-8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

ECG 10-Lead CablesSupply CodeK901

ModelBJ-900P

Description 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 3.8 m, incl. patient electrode lead & connection cableFor current products: BSM-1700/3000/5100/6000/9100/TEC-8300Packing unit: 1 pcs

K354 BJ-831V 10-Lead ECG Patient Cable (12 channel ECG), clip, cable length: 2.5 mFor current products: TEC-8300Packing unit: 1 pcs

Page 49: accessories - nihon kohden

ECG Cables for TEC-5500 & TEC-7700

ECG 3-Lead Cables

ECG 5-Lead Cables

Additional Defi brillator Connection Cables

Page 50: accessories - nihon kohden

www.nihonkohden.net50

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

ECG 3-Lead CablesSupply CodeK120

ModelNA-0003

DescriptionElectrode Lead Tube, for K911/K910AFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 5 pcs

K910A BR-913P 3-Lead ECG Electrode Cable, clip, cable length: 0.8 mTEC-5500/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

K911 BR-903P 3-Lead ECG Electrode Cable, snap, cable length: 0.8 mTEC-5500/7700: for connection to defi brillators L153 is requiredBSM/PVM/TEC-8300: for connection to monitors K922 is requiredFor current products: TEC-5500/7700/8300/all BSM/PVM; ZS-910/920/930/940/530PG; ZM-920/930/940PGPacking unit: 1 pcs

K225 BR-018P 3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs

K226 BR-019P 3-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs

K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode LeadK225/K226/K227/K228For current products: TEC-5500/7700Packing unit: 1 pcs

K352A BC-763VA 3-Lead ECG Connection Cable (AHA), snap, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

K353A BC-763V 3-Lead ECG Connection Cable (IEC), snap, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

Page 51: accessories - nihon kohden

www.nihonkohden.net51

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

ECG 5-Lead CablesSupply CodeK227

ModelBR-020P

Description5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs

K228 BR-021P 5-Lead ECG Connection Cable (IEC), snap, cable length: 0.8 m, for use with L152For current products: TEC-5500/7700Packing unit: 1 pcs

K336 JC-005P Connection Cable (IEC), cable length: 3.0 m, for ECG Electrode LeadK225/K226/K227/K228For old products: TEC-8250/8251Packing unit: 1 pcs

K352B BC-765VA 5-Lead ECG Connection Cable (AHA), clip, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

K353B BC-765V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor current products: TEC-5500/7700Packing unit: 1 pcs

Page 52: accessories - nihon kohden

www.nihonkohden.net52

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

Further Defi brillator Connection CablesSupply CodeK232

ModelBR-002P

Description3-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 mFor old products: TEC-7000Packing unit: 1 pcs

K350A BC-753V 3-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor old products: TEC-7500Packing unit: 1 pcs

K234 BR-004P 5-Lead ECG Connection Cable (IEC), clip, cable length: 0.8 mFor old products: TEC-7000Packing unit: 1 pcs

K332 JC-002P Connection Cable (IEC) for ECG Electrode Lead K234, cable length: 3.0mFor old products: TEC-7000Packing unit: 1 pcs

K351A BC-755V 5-Lead ECG Connection Cable (IEC), clip, cable length: 3.5 mFor old products: TEC-7500Packing unit: 1 pcs

L151 JC-761V External ECG Input Cable, connection to patient monitors, cable length: 2.9 mFor current products: TEC-5500/7700Packing unit: 1 pcs

L152 JC-762V External Defi brillator Connection Cable, cable length: 3.0 m, for ECG Electrode Lead K225/K226/K227/K228For current products: TEC-5500/7700Packing unit: 1 pcs

L153 JC-763V External Defi brillator Connection Cable, cable length: 3.0 m, for ECG Electrode Lead K910A/K911For current products: TEC-5500/7700Packing unit: 1 pcs

Page 53: accessories - nihon kohden

NIHON KOHDEN Vitrode Disposable ECG Electrodes –

The result of over 30 years experience in disposable electrode manufacturing.

The ECG electrodes are the most important portions of the ECG/arrhythmia monitoring system. It is through these electrodes that

the electrical signals are conducted from the patient and into the monitoring system. If the electrodes are left in place for an exten-

ded period of time (over 48 hours), or they are reused once they are removed, they do not adhere to the patient’s skin and they cause

“noisy’’ ECG signals because of the poor conduction. In addition, the patient’s movement causes the electrodes to lose conducting

capabilities intermittently, and this leads to a “wandering’’ ECG waveform and muscle artifact. The standard monitoring practice is

to change these electrodes at least every 48 hours.

Please contact us for individual o� er based on your annual volume! Use the possibility of call orders!

ECG Electrodes for Defi brillators

Standard Electrodes PlacementsIt is important to prepare the skin before attaching

the electrodes by cleaning it and removing chest

hair. After this please attach the lead wire to the

electrodes before placing them on the skin. This

avoids pain to the patient. Secure the lead wire to

the skin (stress loop) preventing moving of the

lead wire and therefore noise on the ECG signal.

ECG Electrodes for Adults

ECG Electrodes for Children,Infants & Neonates

Three electrodes Ten electrodesSix electrodes

Page 54: accessories - nihon kohden

www.nihonkohden.net54

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

ECG Electrodes for AdultsSupply CodeG203

ModelL-150

DescriptionECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, foam tape, solid gel, general usePacking unit: 5 x 30 pcs

G204 C-150 ECG Electrode Vitrode C, Ag/AgCl, adult, size: 47 mm dia, breathable cottony soft-cloth with an elastic quality for tension, solid gelPacking unit: 5 x 30 pcs

G207 L-150X ECG Electrode Vitrode L, Ag/AgCl, adult, size: 35 mm dia, radiolucent (X-ray), foam tape, solid gelPacking unit: 5 x 30 pcs

G210D F-150M ECG Electrode Vitrode F, Ag/AgCl, adult, size M: 25 x 45 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs

G250 J-150 ECG Electrode Vitrode J, Ag/AgCl, adult, size: 40 mm dia, foam tape, solid gel, excellent adhesion even on sweaty skinPacking unit: 5 x 30 pcs

G272A V-09OM3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 30 x 3 pcs

G272B V-040M4 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 4 pre-wired electrodes with 1.5 mm touch proof connector for limb leadsPacking unit: 10 x 4 pcs

Defi brillators > ECG Measurement

Page 55: accessories - nihon kohden

www.nihonkohden.net55

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > ECG Measurement

Supply CodeG272C

ModelV-06OM6

DescriptionECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.0 m, radiolucent (X-ray), hydrogel, foam & cotton tape, 6 pre-wired electrodes with 1.5 mm touch proof connector for chest leadsPacking unit: 10 x 6 pcs

G278A V-09IO3 ECG Electrode Vitrode V, Ag/AgCl, child/adult, size: 25 x 45 mm, cable length: 1.5 m, radiolucent (X-ray), foam tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 30 x 3 pcs

ECG Electrodes for Children, Infants & NeonatesSupply CodeG210C

ModelF-150S

DescriptionECG Electrode Vitrode F, Ag/AgCl, neonate/child, size S: 18 x 36 mm, cotton tape especially for sensitive skin, adhesive gelPacking unit: 3 x 50 pcs

G271A V-120S3 ECG Electrode Vitrode V, Ag/AgCl, neonate/infant, without motif print, size: 20 mm dia, cable length: 0.6 m, radiolucent (X-ray), foam & cotton tape, 3 pre-wired electrodes with 1.5 mm touch proof connectorPacking unit: 40 x 3 pcs

Page 56: accessories - nihon kohden

A Pulse Oximeter is a non-invasive device used to percutaneously measure oxygen saturation

in the blood by use of a clip-on fi nger probe. Pulse oximeter works with the integration of a

probe placed onto patient’s fi ngertip or toe, obtains signals from the probe and the main

device calculates oxygen saturation in the body.

Oxygen saturation measured by a Pulse Oximeter is SpO2. “P” stands for “pulse”, and the

measurement principle is based on beat-by-beat changes in blood volume. In general, arteri-

al oxygen saturation measured by spectroscopic analysis is called “SaO2”, and oxygen satura-

tion measured by pulse oximeter is called “SpO2”.

The method for determination of arterial oxygen saturation, based on the photoelectric ple-

thysmography, was conceptualised and implemented in 1972 by the Japanese bio-engineer

Takuo Aoyagi (NIHON KOHDEN Corporation). This idea came about while using an ear den-

sitometer for recording dilution curves for dyes (pigments). The fi rst commercial oximeter

“OLV-5100” was presented by NIHON KOHDEN back in 1975.

Dr. Aoyagi’s innovative technology, pulse oximetry, has rapidly spread worldwide and become essential in critical care. In

2002, Dr. Aoyagi was awarded the Medal of Honor in Japan, in recognition of his great contribution to clinical medicine.

The NIHON KOHDEN SpO₂ Sensors of the BluPRO® Series are at the cutting edge of this progressive technology.

SpO₂ Measurement

Disposable

Page 57: accessories - nihon kohden

SpO2 Cables

Page 58: accessories - nihon kohden

www.nihonkohden.net58

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > SpO2 Measurement

SpO2 CablesSupply CodeK931

ModelJL-900P

DescriptionSpO2 Connection Cable, cable length: 2.5 m, rectangular connectorFor current products: TEC-8300/all BSM/PVM/PSG-1100Packing unit: 1 pcs

Y095A JL-550T2 SpO2 Connection Cable, cable length: 2.5 m, round connectorFor current products: TEC-5500/7700/JE-912A/921A/921AGPacking unit: 1 pcs

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

NoteSpO2 measurement starts when the SpO2 connection cable and SpO2 probe are connected to the device, and the SpO2 probe is attached to the patient.

When not measuring SpO2, disconnect the SpO2 connection cable from the device. Otherwise, noise from the probe sensor may interfere and incorrect data is displayed on the screen.

Page 59: accessories - nihon kohden

Reusable SpO2 Probes

Disposable SpO2 Probes

BluPRO® SpO₂ Probes – A Unique Sensing Technology

Reliability and high quality of our probes provide a continuous accurate and safe monitoring with highest patient

comfort. The comfortable, sure fi tting and lightweight characteristic reduces the e� ect of hand movement for

highly reliable SpO2 measurement.

This ensures patient safety, reduces the costs of care and increases therefore clinical e� ciency and cost

e� ectiveness. NIHON KOHDEN BluPRO® SpO2 Probes are comfortable, durable, accurate and needs-oriented.

Note that accurate and safe measurement is assured only when you use probes, connection cords and parts manu-

factured by NIHON KOHDEN. Some probes in the market may advertise as „compatible with NIHON KOHDEN

probes.“ We strongly recommend you to avoid these probes as a correct measurement cannot be guaranteed on

NIHON KOHDEN devices. NIHON KOHDEN is not responsible for problems caused by using other manufacturer’s probes.

Please contact us for an individual o� er based on your annual volume! Use the possibility of call orders!

SpO₂ Probes

Page 60: accessories - nihon kohden

www.nihonkohden.net60 www.nihonkohden.net60 Defi brillators > SpO₂ Measurement

SpO₂ Probes

Low birth weight

Neonate Infant Child Adult

2 kg 3 kg1000 g 30 kg10 kg 20 kg 40 kg 50 kg

Dis

posa

ble

Reus

able

P204F (TL-272T3)

P203C (TL-273T)

P203D (TL-274T)

P204C (TL-273T)

P204D (TL-274T)

P228A (TL-051S)

P229A (TL-061S)

P225F (TL-201T)

P204G (TL-273T3)

P204H (TL-274T3)

P228B (TL-052S)

P229B (TL-062S)

P225H (TL-201T1)

P225G (TL-220T)

P203G (TL-273T3)

P203H (TL-274T3)

P204B (TL-272T)

P203E (TL-271T3)

P203A (TL-271T)

P204E (TL-271T3)

P203F (TL-272T3)

P204A (TL-271T)

P203B (TL-272T)

Supply Code (Model)

Cable length (m)

Packing unit

1.6

0.8

0.8

0.8

0.8

0.8

0.8

1.6

1.6

1.6

1.6

1.6

0.6

1.6

1.6

1.6

0.8

1.6

0.8

1.6

1.6

0.8

0.8

24

5

5

5

24

5

24

5

24

5

P310C (TL-630T3) 1.6

P311C (TL-631T3) 1.6

1

Page 61: accessories - nihon kohden

www.nihonkohden.net61

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > SpO2 Measurement

Reusable SpO2 Probes

FactsNIHON KOHDEN reusable SpO2 fi nger-clips probes have parallel mounted upper and lower sensor shells, thus, providing an exact alignment of the op-tical sensor components and markedly enhanced comfort during long-term attachment. In addition, fl exible lateral fl aps shield the measuring signals from the external light, thus resulting to minimize the interference by additional artifi cial light sources! Bright LEDs provide more accurate measure-ment even for thicker fi ngers or dark skin tones. The fi nger-clip reusable probe is the most popular type of SpO2 probes. Instead of the typical hinge near the fi nger tip, P225F/P225H have a unique sure fi tting and comfortable mechanism using two sliding pieces for the front and back of the fi nger with two rubber fl aps along both sides of the fi nger. When you press the button, the two halves of the probe slide directly open, parallel to each other. No additional fi xation tape is needed. For a stable and comfortable measurement P225F/P225H, always keep the light emitters and detector aligned. NIHON KOHDEN provides unique reusable SpO2 probes.

Supply CodeP225F

ModelTL-201T

DescriptionSpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 1.6 m, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs

P225H TL-201T1 SpO2 BluPRO® Finger-Clip Probe, child/adult (> 20 kg) finger, cable length: 0.6 m, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs

FactsThe multi-site probe P225G can be used for neonatal feet as well as adult fi ngers as its curved contact surface is designed to fi t on di� erent attachment sites. The light emitter and detector are separate which allows especially an accurate alignment of the LED on the infant/neonatal instep. A unique sliding adjuster gives the best fi t on the attachment site secured by taping.

Supply CodeP225G

ModelTL-220T

Description SpO2 BluPRO® Multi-Site Probe, neonate (< 3 kg) instep,child/adult ( > 3 kg) fi nger/toe, cable length: 1.6 m, reusableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs

Reusable, but always clean – NIHON KOHDEN washable probes.

The reusable probes of the BluPRO® series are durable and washable, so you can clean them under running water or even immerse them in a soapy alkaline or disinfectant solution (glutaraldehyde solution 2.0 % or hydrochloric alkyl diaminoethylene glycine 0.5 %)! P225F / P225H P225G

Durable, washable, demand-oriented!P310C / P311C

Page 62: accessories - nihon kohden

www.nihonkohden.net62

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Facts Our special designed fi nger-tip probes, P310C and P311C, fi t immediately on the fi nger and are perfect for long-term measurement. A less covered fi nger area and cushioned materials lead to decrease pressure to the attachment site. The 3D molding attachment ensures a comfortable fi t. In combination with the soft and lightweight design the patient stress or discomfort is reduced and the probes can be remained up to 8 hours to one attachment site. A stable measurement is assured by gentle fi xation tapes P263 or P267 that avoid the falling o� of the probes and reduce artifact from cable movement.Reusable but with the comfort of a disposable probe, P310C and P311C are also applicable for sleep studies, for patients that are often bending their fi ngers or obese patients.

Supply CodeP310C

ModelTL-630T3

Description SpO2 BluPRO® Finger-Tip Probe L, child/adult (> 50 kg) fi nger, cable length: 1.6 m, long-term use, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs

P311C TL-631T3 SpO2 BluPRO® Finger-Tip Probe M, child/adult (> 20 kg) fi nger, cable length: 1.6 m, long-term use, reusableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 1 pcs

P263 Disposable Probe Cable Fixing Tape for P310C/P311C, size: 15 x 130 mmFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 3 x 30 pcs

P267 YS-093P2 Disposable Probe Fastener Tape for P310C/P311C,size: 15 x 140 mmFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 30 pcs

Defi brillators > SpO2 Measurement

Page 63: accessories - nihon kohden

www.nihonkohden.net63

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Disposable SpO2 Probes NIHON KOHDEN disposable probes, from neonate to adult sizes, place special emphasis on the exact positioning of the LEDs and detector. For this reason the two optical components are designed separately and can thus be brought into precise alignment with each other by the user. All probes have breathable material and can be remained up to 8 hours on one attachment site. Paediatric probes have a cute cartoon character printed on the tape to reassure children.

Self-adhesive, soft and thin tape provides a secure fi t. The special design allows an easy application to the attachment site. To get the most comfortable fi t, please bend the probe before attaching, do not strongly pull the attachment tape when attaching and do not push the tip of the fi nger with the attachment tape.

Disposable SpO2 Probes 24 pcs/box – cable length: 0.8 m

Supply CodeP203A

ModelTL-271T

Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203C TL-273T SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 0.8 m, disposableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203D TL-274T SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

Defi brillators > SpO2 Measurement

Page 64: accessories - nihon kohden

www.nihonkohden.net64

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Disposable SpO2 Probes 24 pcs/box – cable length: 1.6 m

Supply CodeP203E

ModelTL-271T3

Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203F TL-272T3 SpO2 BluPRO® Probe, child ( 10 – 50 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

P203H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 1.6 mFor current products:all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 24 pcs

Disposable SpO2 Probes 5 pcs/box – cable length: 0.8 m

Supply CodeP204A

ModelTL-271T

Description SpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P204B TL-272T SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

Defi brillators > SpO2 Measurement

Page 65: accessories - nihon kohden

www.nihonkohden.net65

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Supply CodeP204C

ModelTL-273T

Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P204D TL-274T SpO2 BluPRO® Probe, infant ( 3 –20 kg) fi nger/toe, cable length: 0.8 m For current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

FactsAbsolutely cost-e� ective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced!The light emitter and detector are covered by sponge and the entire attachment site has a fl at surface. This reduces the risk of skin burn and irritation. Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached fi nger. For fi xation, wrap the probe around the fi nger with attachment tape P259.

Supply CodeP228A

ModelTL-051S

Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) fi nger, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P229A TL-061S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) fi nger, cable length: 0.8 mFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P259 COTTONY Tape for fi xing disposable SpO2 ProbesFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 20 pcs

Defi brillators > SpO2 Measurement

Page 66: accessories - nihon kohden

www.nihonkohden.net66

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Disposable SpO2 Probes 5 pcs/box – cable length: 1.6 m

Supply CodeP204E

ModelTL-271T3

DescriptionSpO2 BluPRO® Probe, adult (> 30 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P204F TL-272T3 SpO2 BluPRO® Probe, child (10 – 50 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P204G TL-273T3 SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 40 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P204H TL-274T3 SpO2 BluPRO® Probe, infant (3 – 20 kg) fi nger/toe, cable length: 1.6 mFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

Defi brillators > SpO2 Measurement

Page 67: accessories - nihon kohden

www.nihonkohden.net67

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

FactsAbsolutely cost-e� ective, the series P228 and P229 are intended for long-term measurement on a single patient. The probes do not need to be replaced with a new one before 96 hours by changing the attachment site every 8 hours. So your running costs can be reduced! The light emitter and detector are covered by sponge and the entire attachment site has a fl at surface. This reduces the risk of skin burn and irritation. Since the probe itself is not self-adhesive, you can easily remove and attach the probe to change the attached fi nger. For fi xation, wrap the probe around the fi nger with attachment tape P259.

Supply CodeP228B

ModelTL-052S

Description SpO2 BluPRO® Probe, neonate (< 3 kg) instep, adult (> 50 kg) fi nger, cable length: 1.6 m, disposableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P229B TL-062S SpO2 BluPRO® Probe, infant/child (3 – 15 kg) toe, child (15 – 50 kg) fi nger, cable length: 1.6 m, disposableFor current products: all BSM/PVM/TEC/EEG; ZS-930/530/940PG; ZM-930/940PGPacking unit: 5 pcs

P259 COTTONY Tape for fi xing disposable SpO2 Probes, disposableFor current products: all BSM/PVM/TEC/EEG/PSG-1100; ZS-930/530/940PG; ZM-930/940PGPacking unit: 20 pcs

Handling of the probe a� ects measurement accuracy and patient safetyFor the proper placement of the probe on the fi nger, it is advisable that the light emitter and detector are placed just opposite to each other. When using a fi nger clip probe, it is necessary to ensure that the probe covers the fi nger properly, otherwise some portion of the light never passes through the body tissues and may reach the light-receiving part directly, leading to incorrect measurement results.

The more distant the light emitter and detector gets, the weaker the transmitted light intensity becomes. Additionally, a thinner body part tends to have small amount of blood, which makes it di� cult to extract the arterial blood signal component. The most suitable thickness of the probe site is about 10 mm.

Too loose probes may interfere with alignment of LEDs and detector, come o� easily by body movement, cause larger motion artifacts or be e� ected by venous pulse.

Too tight probes may cause venous pulsation, cause skin injuries such as burn and necrosis or unstable measurement because of a lower pulsatile signal.

Defi brillators > SpO2 Measurement

Page 68: accessories - nihon kohden

Reasons to measure ETCO₂ (the level of carbon dioxide in the air exhaled from the body –

normal value is about 38 mm Hg): Capnography helps to detect life-threatening problems in:

• Airway

• Breathing

• Circulation and

• Metabolism

Capnography is a fast and reliable help to determinate respiratory di� culties, wrong connections of airway

adapters, leaks in the ventilator circuit due to its placement in the respiratory circuit. An early detection by

capnography might help to avoid inadequate oxygen supply of the body.

ETCO2 Measurement (Capnography)

Page 69: accessories - nihon kohden

www.nihonkohden.net69 www.nihonkohden.net69 Defi brillators > ETCO2 Measurement

ETCO2 Measurement (Capnography)The necessity of monitoring ETCO2 is recognized by various health care associations guidelines:

Canadian Anesthesia Society (CAS)Guidelines for Sedation – January, 2012

Anesthesia Patient Safety Foundation (APSF)Monitoring with Use of Post-op Opioids – August, 2011

American Society for Anesthesiologists (ASA)Standards for Basic Anesthetic Monitoring – July, 2011

Association of Anaesthetists of Great Britain & Ireland (AAGBI) The use of capnography outside the operating theatre – May, 2011

American Association of Respiratory Care (AARC) CPG for Capnography/Capnometry During Mechanical Ventilation – April, 2011

British Royal College of AnesthetistsAirway Recommendation (NAP4) – March, 2011

European Resuscitation Council (ERC)Guidelines for Resuscitation – November, 2010

American Heart Association (AHA)Resuscitation Guideline – November, 2010

Suck in

Sampling tube

Sidestream Method

In a sidestream system, a gas

sample is removed from the

patient’s airway and delivered

to a distant sensor.

Measurement values delayed.

Not possible with

NIHON KOHDEN defi brillators.

Capnometer

CO2 Sensor

CO2 Sensor

Mainstream Method

In a mainstream system, the

sensor is located directly in

the patient’s breathing circuit.

Real time measurement values.

Capnometer

Is CO2 the only gas to measure?

Is the patient a neonate?

Is the patient intubated?

Mainstream measurement

Yes

Yes

Yes

Yes

No

No

Multi-gas measurement

Please use NIHON KOHDENpatient monitors!

CO2 sensor kit P907 (TG-920P) & P908 (TG-921T3)

Both intubated & non-intubated

Emergency

Is a humidifi er or nebulizer used?

CO2 sensor kit P909 (TG-970P)

R805 (YG-211T) Airway adapter adult (> 7 kg)

CO2 sensor kit P909 (TG-970P)

R805 (YG-211T) Airway adapter adult (> 7 kg)

CO2 sensor kit P903 (TG-900P)R801 (YG-101T) Airway adapter adult, (> 10 kg)

With nebulizer

No

Intubated

R804 (YG-111T) Airway adapter (> 7 kg)

Non-intubated

No

V921 (YG-120T) Nasal adapter (> 10 kg)

V922 (YG-121T) Nasal/Oral adapter (>10 kg)

V923 (YG-122T) Nasal/Oral adapter with O₂ supply tube adapter (> 10 kg)

NKD-02-Cap Oxygen cannula

No measurement possible

No

Start ETCO2 Selection Guide

Page 70: accessories - nihon kohden

Normal capnograph and ETCO2 waveform

ETCO2 shows clinical and technical problems

ETCO2 Measurement OverviewThe best way to observe the patient‘s respitatory condition

Normal range: steep rising and fl at expiratory phase Hyperventilation Hypoventilation

mmHg

PaCO2 level

ETCO2

45

35

Hypoventilation Increasing CO Malignant high fever Pain of light anesthesia

Normal range

HyperventilationDecreasing COPulmonary embolismDeep anesthesia

Trend

· Downward · Upward

Disconnection in breathing circuitAsphyxiaVentilator stop

HyperventilationDecreasing COPulmonary embolism Temperature decrease

Partial obstruction ofbreathing circuit

Sudden disappearance of CO2 waveform

HypoventilationTemperature increaseMalignant high fever

40

40

40

40

Breathing circuit abnormality Respiratory abnormality

Sudden decrease of CO2 Gentle expiratory phase

· Breathing circuit abnormality · Obstructive defect, bronchial spasm ETCO2=PaCO2

40 40

Sudden decrease of CO2 toward zero Gentle expiratory phase

· Ventilation disconnection · Rebreathing

40 40

Zero CO2 or very low CO2 Cumulative irregular respiratory waveform

· Esophageal intubation · Spontaneous breathing

40 40

CO2monitor

Bloodcirculation

BreathingAirway

MetabolismPulmonary circulation

Gas exchange

Connector Ventilator

Respiratory Circuit

Fresh gasCO2 absorber

Conditions refl ected by ETCO25 phases of the capnograph

Beginning ofexhalation

Start exhalationof CO2 in alveoliof the lung

Plateau of CO2 in alveoli of the lung

Inhalation phase

End of exhalation

ETCO2 and PaCO2 show ventilation and pulmonary blood fl ow condition

46 mmHg 46 mmHg

40 mmHg ( PaCO2)

40 mmHg ( ETCO2)

40 40 404640

40

43 mmHg ( PaCO2)

20 mmHg ( ETCO2)

40 mmHg ( PaCO2)

Normal ventilation Abnormal ventilation and normal pulmonary blood fl ow

Normal ventilation and abnormal pulmonary

blood fl ow

46 mmHg 46 mmHg 46 mmHg 46 mmHg

40 mmHg ( ETCO2)

Early detection of trouble in breathing or ventilation equipment

Inadequateventilation Kink Disconnection

Apnea Obstruction

Esophageal intubation

Leak

Malfunction

Indequategas fl ow

CO2 Measurement is useful in many hospital sites

ER ICU SedationPSG

Nihon Kohden Unique Sensing Technology

40 40 040

Page 71: accessories - nihon kohden

ETCO2 Mainstream

Application Fields of Airway Adapters for Intubated Patients

Application Fields of Nasal Adapters for Non-Intubated Patients

Emergency / Pre-hospital Care

• Detection of endotracheal tube displacement• Control of CPR effi cacy• ROSC detection (Return of Spontaneous Circulation)• Oxygenation management• Airway circuit management • Keeping ICP appropriate by checking ETCO2 level (i.e. patients with craniocerebral injury – CCI) • Detection of respiratory distress (occlusion, connection leak, accidental extubation, ventilator trouble etc.)• Detection of poor pulmonary perfusion• Apnea monitor• Detection of eff ectiveness of treatment

Transport / Pre-hospital Care

• Detection of changes in respiratory status (over- or underventilation of trauma / shock victims; COPD patients)• Detection of respiratory depression of sedated patients or anaesthesia without intubation• Spot-checking of ETCO2 level & respiration rate of critically ill non-intubated patients• Detection of eff ectiveness of treatment

Page 72: accessories - nihon kohden

www.nihonkohden.net72

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Intubated Expired ETCO2

Supply CodeP906

ModelTG-901T3

DescriptionCO2 Sensor Kit for Intubated Patients, semi-quantitative measurement, incl. CO2 sensor and CO2 adapter, expiratory CO2, cable length: 3.0 m For Airway Adapters: R801For current products: TEC-5500/7700Packing unit: 1 pcs

P903 TG-900P CO2 Sensor Kit for Intubated Patients, semi-quantitative measurement, incl. P922A/K981, expiratory CO2, cable length: 3.0 m For Airway Adapters: R801For current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs

P922A TG-101T CO2 Sensor for Expiratory CO2 for Intubated Patients, part of CO2 Sensor Kit P903, cable length: 1.0 m, requires Adapter Cable: K981For current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs

K981 JG-900P CO2 Adapter Cable for P922A/P903, cable length: 2.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 1 pcs

R801 YG-101T Airway Adapter for P903/P906/P922A, intubated, semi-quantitative method, child/adult (>10 kg), dead space: 5 mlFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300Packing unit: 50 pcs

Defi brillators > ETCO2 Measurement

Page 73: accessories - nihon kohden

www.nihonkohden.net73

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Intubated Expired and Inspired ETCO2 “Opening a New Era in Capnography“

Facts

NIHON KOHDEN CO2 Sensor Sensation - P909 World‘s smallest and lightest mainstream ETCO2 sensor (quantitative method) with only 4 g (±2 g). This avoids tube pressures and increases patient comfort. Especially for this reason as well as the dead space of approximately 1 ml it is perfectly suited to the most sensible intubated patients – neonates in critical care (application on neonates only with patient monitors). Besides this P909 can be also applied to children and adults. Easy and simple handling is guaranteed by its waterproofness (IPX7 standard) and our Smart CableTM Technology so that no additional module is needed. Just plug in and start a continuous measurement after only 10 seconds warm-up time. Those features make the P909 an unbeatable help for daily work routine in OR, ER, ICU or Ward.

Supply CodeP909

ModelTG-970P

Descriptioncap-ONE CO2 Sensor Kit for Intubated Patients, quantitative measurement, incl. P924/K987, size: 8 x 13 x 35 mm, cable length: 3.5 mFor Airway Adapters: R805For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

P924 TG-221T cap-ONE CO2 Sensor for Intubated Patiens, part of CO2 Sensor Kit P909, cable length: 3.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

K987 JG-970P cap-ONE CO2 Adapter Cable for P909/P924, cable length: 0.5 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

R805 YG-211T Airway Adapter for P909, intubated, quantitative method, adult (> 7 kg), dead space: 4 mLFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 30 pcs

Defi brillators > ETCO2 Measurement (Capnography)

Page 74: accessories - nihon kohden

www.nihonkohden.net74

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Intubated and Non-Intubated Expired ETCO2 “Opening a New Era in Capnography“FactsNIHON KOHDEN cap-ONE–when every breath counts!World’s fi rst wearable mainstream ETCO2 sensor P907 (semi-quantitative method) for intubated and non-intubated patients which is applicable for children and adults.Unique oral-nasal airway adapters catch oral as well as nasal expired CO2 – this increases accuracy. The cap-ONE is not only small but has also a mini-weight of only 4 g. This avoids tube pressures and increases patient comfort. Easy and simple handling is guaranteed by our Smart CableTM Technology so that no additional module is needed, just plug in and start measuring after only 5 seconds. A continuous, stable and accurate measurement is ensured due to no lag time and no need to change tubes because of occlusions. Its waterproofness and outstanding shock resistance are an unbeatable advan-tage in daily work routine. Those features make the cap-ONE P907 an excellent measurement tool in OR, ICU, Recovery Room, PACU, Transport, ER, Cardiac Catheter Laboratory, GI Endoscopy, Pain Management, Abdominal Operation, Obstetric/Orthopedic/Eye Surgery, Plastic or Dental Surgery.

Supply CodeP908

ModelTG-921T3

Descriptioncap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative measurement, incl. CO2 sensor and CO2 Adapter, size: 11 x 11 x 40 mm, cable length: 3.5 mFor Airway Adapters: Intubated patients: R804Non-Intubated patients: V921/V922/V923For current products: all EEG/TEC-5500/7700; EEG-1200/9100/9200 with JE-921A/921AGPacking unit: 1 pcs

P907 TG-920P cap-ONE CO2 Sensor Kit for Intubated/Non-Intubated Patients, semi-quantitative measurement, incl.P923/K984, size: 11 x 11 x 40 mm, cable length: 3.5 mFor Airway Adapters: Intubated patients: R804Non-Intubated patients: V921/V922/V923For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

P923 TG-121T cap-ONE CO2 Sensor for Intubated/Non-Intubated Patients, part of CO2 Sensor Kit P907/P908, cable length: 1.5 mRequires Adapter Cable: K984For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

K984 JG-920P cap-ONE CO2 Adapter Cable for P923/P907, cable length: 2.0 mFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 1 pcs

Defi brillators > ETCO2 Measurement (Capnography)

Page 75: accessories - nihon kohden

www.nihonkohden.net75

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Supply CodeR804

ModelYG-111T

DescriptionAirway Adapter for P907/P908/P923, intubated, child/adult (> 7 kg), dead space: 4 mLFor current products: all BSM/PVM-2703/OLG-2800/TEC-8300/PSG-1100Packing unit: 30 pcs

V921 YG-120T CO2 Nasal Adapter for Nasal Breathing, non-intubated, child/adult (> 10kg)For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs

V922 YG-121T CO2 Nasal Adapter for Nasal/Oral Breathing, non-intubated, child/adult (> 10 kg)For current products:all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs

V923 YG-122T CO2 Nasal Adapter for Nasal/Oral Breathing with Oxygen Cannula Holder,non-intubated, child/adult (> 10kg)For current products: all BSM/PVM-2703/OLG-2800/TEC-8300/EEG/PSG-1100Packing unit: 30 pcs

NKD-O2-CAP Oxygen Cannula for Nasal Adapter V923 for P907/P908For current products: all BSM/PMV-2703/OLG-2800/TEC-8300/EEGPacking unit: 50 pcs

NKD-CO2GAS Calibration Gas for CO2 Measurement Please store the gas below 50°C!For current products: all BSM/TEC-8300Packing unit: 1 pcs

NKD-VENTIL3 CO2 Gas ValveFor current products: all BSM/TEC-8300Packing unit: 1 pcs

Defi brillators > ETCO2 Measurement (Capnography)

Page 76: accessories - nihon kohden

Temperature Measurement

StandardTemperature

Measurement of 2 Additional Temperatures

Page 77: accessories - nihon kohden

www.nihonkohden.net77

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Temperature Measurement

Standard Temperature Measurement

Supply CodeNKD-P240A

ModelYSI-401

DescriptionOesophagus/Rectum Thermistor Probe, adult, 6.3 mm jack connector, size: 4 mm dia, length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-P241A YSI-402 Oesophagus/Rectum Thermistor Probe, neonate/child, 6.3 mm jack connector, size: 3.3 mm dia, length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-P242B YSI-409B Body Surface Temperature Probe, 6.3 mm jack connector, disk size: 9.5 mm dia, cable length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 1 pcs

NKD-P249 ZM: S616 Temperature Probe Cover for NKD-P240A/241AFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 10 pcs

Tempheart Adhesive Pads, to fi x temperature probes, size: 1.5 cm diaFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 100 pcs

Mini-Tempheart Adhesive Pads, to fi x temperature probes, size: 1.13 cm diaFor current products: all BSM/PVM-2703/TEC-8300/MEB-9200/MEB-2300Packing unit: 100 pcs

Measurement of 2 Additional Temperatures

Supply CodeK961

ModelJT-900P

DescriptionTemperature Connection Cable for NKD-P241/242x, cable length: 0.3 mFor current products: BSM-5100/6000/9100/ TEC-8300Packing unit: 1 pcs

NKD-TEMPHEARTS4009

NKD-TEMPHEARTS4012

Page 78: accessories - nihon kohden

NIBP Air Hoses

Disposable NIBP Cu� s

Reusable NIBP Cu� s – NEW YAWARA CUFF 2

Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the blood

pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the condition

of the pumping function of the heart as an important vital sign.

A non-invasive indirect method to measure the blood pressure is the oscillometric blood pressure measurement. This me-

thod is using an infl ated blood pressure cu� which is applied to the patient’s arm or thigh. The blood pressure is detected

by partial occlusion of the artery by the cu� . The so called Korotko� sound is generated by the distension of the arterial

wall with each cardiac impulse. Systolic and diastolic blood pressures are determined by an algorithmic interpretation of

the device based on the mean arterial pressure and changing amplitude of the Korotko� sounds.

For a proper non-invasive measurement it is important to use the correct cu� size due to the fact that a cu� too small will

lead to faulty high pressure, while a large cu� can lead to wrong low pressure readings.

NIBP Measurement (Non-Invasive Blood Pressure)

Page 79: accessories - nihon kohden

www.nihonkohden.net79

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)

NIBP Air Hoses

Supply CodeS901

ModelYN-900P

DescriptionChild/Adult NIBP Air Hose, cable length: 1.5 mFor current products: all BSM/PVM/TEC-7700/8300Packing unit: 1 pcs

S902 YN-901P Child/Adult NIBP Air Hose, cable length: 3.5 mFor current products: all BSM/PVM/TEC-7700/8300Packing unit: 1 pcs

S903 YN-990P NIBP Air Hose Extension Cable, cable length: 1.5 mFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

Page 80: accessories - nihon kohden

www.nihonkohden.net80

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)

Reusable NIBP Cu� s – NEW YAWARA CUFF 2

Facts The trade name YAWARA CUFF comes from the Japanese word, YAWARAKAI, whichmeans soft in touch.YAWARA CUFF 2 is available in 6 sizes. The exterior size-scale quickly helps inselecting the proper cu� size, from infant to large adult or thigh.The velcro part of the cu� is divided into two high quality velcro types. This helpsto fi x the cu� on the arm with the fi rst velcro part whereas you can completelyadjust the cu� with the second velcro part.YAWARA CUFF 2 uses a soft and smooth cloth together with a bu� er sheet to reduce the risk of subcutaneous bleeding. The fabric is hypoallergic and allows the skin to breathe. Furthermore, the material of the cloth can be easily wiped clean.A wider opening of the cu� cover allows very easy removal of the bladder forcleaning.The watertight connector cap keeps out liquid during cleaning the bladder. Thereis a nylon fi bre inside the air tube for kink-free tube. There is a nylon fi bre inside the air tube preventing kinking and incidents associated with tube kinking. YAWARA CUFF 2, a new generation of NIBP cu� s.

Kink-free tubeEasy to clean with watertight connection cap

Indicator of appropriate range of attachment site

Easy handling of an infl ation bagWith a wide slit, it is easy to remove and replace the infl ation bladder.

YAWARA CUFF 2 has a kink-free tube. The tube will not kinked - even if bent through a 180-degree angle.

YAWARA CUFF 2 has a watertight connector cap, which prevents fl uid from entering the tube (and bladder) during cleaning.

With a clear indication of PROPER SIZE printed on the cu� , you can see at a glance if the cu� size is correct for your patient.

Reducing internal bleedingIf wrinkles are formed as below, part of the measuring site may be trapped in the valley portions of the wrinkles, which could cause internal bleeding. YAWARA CUFF 2 has a cushion between an infl ation bag and skin to avoid these wrinkles and reduces internal bleeding.

cushion

wrinklesinfl ation bag

• Soft and gentalon the skin• Highly accurate• Easy to use

Page 81: accessories - nihon kohden

www.nihonkohden.net81

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)

Supply CodeS951A

ModelYP-710T

DescriptionInfant NIBP YAWARA CUFF 2, width: 5 cm, arm-circumference: 8 to 13 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

S951B YP-711T Child NIBP YAWARA CUFF 2, width: 7 cm, arm-circumference: 13 to 19 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

S951C YP-712T Adult Small NIBP YAWARA CUFF 2, width: 10 cm, arm-circumference: 19 to 23 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

S951D YP-713T Adult NIBP YAWARA CUFF 2, width: 13 cm, arm-circumference: 23 to 33 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

S951E YP-714T Adult Large NIBP YAWARA CUFF 2, width: 16 cm, arm-circumference: 33 to 45 cm, latex-freeFor current products: BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 pcs

S951F YP-715T Adult Thigh NIBP YAWARA CUFF 2, width: 19 cm, thigh-circumference: 45 to 55 cm, latex-freeFor current products: BSM/PVM/TEC-77/8300; ZS/ZM-940PGPacking unit: 1 pcs

Page 82: accessories - nihon kohden

www.nihonkohden.net82

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)

Disposable NIBP Cu� sDisposable NIBP Cu� s for Infants & Children

Supply CodeNKD-NIBP/K2

Description Disposable NIBP Cu� Trial Kit for ChildrenSet contains:3 cu� s of NKD-S947A4 cu� s of NKD-S947B3 cu� s of NKD-S947CFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 set

NKD-S947A Infant NIBP Cu� , width: 6 cm, arm-circumference: 8 to 14 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947B Child NIBP Cu� , width: 8 cm, arm-circumference: 13 to 20 cm, color: green, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947C Small Adult NIBP Cu� , width: 10 cm, arm-circumference: 18 to 26 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs D

Page 83: accessories - nihon kohden

www.nihonkohden.net83

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > NIBP Measurement (Non-invasive Blood Pressure)

Disposable NIBP Cu� s for Adults

Supply CodeNKD-NIBP/K3

Description Disposable NIBP Cu� Trial Kit for AdultsSet contains:1 cu� of NKD-S947C4 cu� s of NKD-S947D3 cu� s of NKD-S947F2 cu� s of NKD-S947HFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 1 set

NKD-S947C Small Adult NIBP Cu� , width: 10 cm, arm-circumference: 18 to 26 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947D Adult NIBP Cu� , width: 14 cm, arm-circumference: 26 to 35 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947E Adult Long NIBP Cu� , width: 15 cm, arm-circumference: 29 to 38 cm, color: red, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947F Large Adult NIBP Cu� , width: 17 cm, arm-circumference: 32 to 42 cm, color: green, latex-free, disposableFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947G Large Adult Long NIBP Cu� , width: 18 cm, arm-circumference: 35 to 44 cm, color: orange, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

NKD-S947H Adult Thigh NIBP Cu� , width: 20 cm, arm-circumference: 42 to 50 cm, color: blue, latex-freeFor current products: all BSM/PVM/TEC-7700/8300; ZS/ZM-940PGPacking unit: 20 pcs

Page 84: accessories - nihon kohden

Blood pressure (BP) is the pressure exerted by circulating blood against the artery walls. During each heartbeat, the

blood pressure varies between a maximum (systolic) and a minimum (diastolic) pressure. The variation indicates the

condition of the pumping function of the heart as an important vital sign.

A direct method to measure the blood pressure is the invasive blood measurement using catheters inserted into the

blood vessels, fi lled with saline solution and measure the pressure electrically with a connected transducer.

IBP Measurement (Invasive Blood Pressure)

Transducer Cable with Direct Connection

IBP Transducer Cable with Adapter Cable K952

Page 85: accessories - nihon kohden

www.nihonkohden.net85

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > IBP Measurement (Invasive Blood Pressure)

IBP Transducer Cable with Direct Connection

Supply CodeK951

ModelJP-900P

DescriptionIBP Connection Cable for Becton Dickinson Transducers, cable length: 3.5 mFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

K952 JP-910P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

K957 JP-960P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

L901 JP-920P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

L902 JP-921P For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

Page 86: accessories - nihon kohden

www.nihonkohden.net86

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > IBP Measurement (Invasive Blood Pressure)

IBP Transducer Cable with Adapter Cable K952

Supply CodeNKD-5203201

DescriptionIBP Connection Cable for B. Braun Transducers, cable length: 3.0 m, requires K952For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-BDP178NK1 IBP Connection Cable Set for Codan Transducers, incl. adapter cable with1 Pressure Connection, contact board Xtrans BDC901 and holding plate B180090, cable length: 0.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 set

NKD-BDP178NK4 IBP Connection Cable for Codan Transducers with 4 Pressure Connections, cable length: 0.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-9003, DPT-9009, DPT-9300, DPT-9990For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-BDPT-1078 IBP Connection Cable for Codan Transducers with 1 Pressure Connection, cable length: 3.5 m, requires K952Applicable for Codan Transducers: Series xTrans: DPT-6000For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/LOGICAL IBP Connection Cable for Medex Transducers with 1 Pressure Connection, cable length: 4.0 m, requires K952Applicable for Medex Transducers: Series LogicalFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/LOGICAL2 IBP Connection Cable for Medex Transducers with 2 Pressure Connections, cable length: 4.0 m, requires K952Applicable for Medex Transducers: Series LogicalFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

Page 87: accessories - nihon kohden

www.nihonkohden.net87

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > IBP Measurement (Invasive Blood Pressure)

Supply CodeNKD-IBP/LOGICAL3

DescriptionFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/LOGICAL4 For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/NOVATRANS For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/TRANSPAC IBP Connection Cable for TRANSPAC Transducers with 1 Pressure Connection, cable length: ca. 4.5 m, requires K952Applicable for Abbott Transducers: Transpac IT, Transpac IVFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/TRANSTAR For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/UTAH plusFor current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

NKD-IBP/UTAH2 For current products: all BSM/PVM-2703/TEC-8300Packing unit: 1 pcs

Page 88: accessories - nihon kohden

www.nihonkohden.net88

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Enhancement of patient status due to optimized quality and effectiveness of chest compression (detectable with ETCO2 value)

For inexperienced users, for fi rst aid trainings, in hospitals, airports and aircrafts/trains and/or for rescue operations.

• Applicable to adults and children from 8 years!

• 10 hours non-stop operation (acoustic warning) or up to 5 years stand-by time!

• Available in 17 different languages!

(stock: German, English, Italian, French, Spanish; on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian, Polish, Portuguese, Russian, Swedish, Hebrew, Croatian)

Portable CPR – For use by anyone! Reusable, portable and smart – a simple and fast emergency aid tool for chest compression!

Ideal tool for professionals and inexperienced users due to continuous real time feedback during chest compression

NKD-CPR

Perfecting of chest compression effectiveness (ideal compression depth 4 - 5 cm, 100 compressions/minute) complies with current ERC Guidelines

Continuous acoustic and visual real time feedback for compression frequence and depth during chest compression (metronome/verbal directions/light-emitting diodes)

Only a few steps may help save a life:

• Stay calm!

• Check the responsiveness/consciousness of the person with cardiac arrest (victim)!

• Call to an emergency doctor! / Call for help!

• If available, use an AED (defi brillator for inexperienced users with verbal directions / visual aid) and a Pocket CPR!

• Check the breathing of the concerned person (victim) and free the airway if necessary!

• Start chest compression (30 x) and perform rescue breathing to the victim (2 x)!

• Continue with chest compressions and rescue breaths in a ratio of 30:2 (30 chest compressions, 2 rescue breaths) until the appearance of the emergency doctor!

Defi brillators > Portable CPR

Page 89: accessories - nihon kohden

www.nihonkohden.net89

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Portable CPR

Portable CPR

Supply CodeNKD-CPR

DescriptionPortable CPR Please indicate your language when ordering! Available languages on stock : German, English, French, Italian, SpanishAvailable languages on request: Danish, Finnish, Dutch, Hungarian, Czech, Norwegian, Polish, Russian, Swedish, Hebrew, CroatianPacking unit: 1 pcs

NKD-SIPADS Disposable Silicone Pads for Portable CPR, 3 mm self-adhesive silicone pads for optimal placement of the Portable CPR on patient�s chestPacking unit: 5 pcs

NKD-STPADS Disposable Sticky Pads for Portable CPR, thin self-adhesive pads for optimal placement of the Portable CPR on patient�s chestPacking unit: 50 pcs

NKD-CPR/COVER Silicone Cover for Portable CPRPacking unit: 1 pcs

Page 90: accessories - nihon kohden

Additional Defi brillator Accessories

Page 91: accessories - nihon kohden

www.nihonkohden.net91

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Additional Defi brillator Accessories

Additional Defi brillator Accessories

Supply CodeF015

ModelZ-101EA

Description“Gelaid” Defi brillator Contact Gel, 100 g tubeFor current products: all TECPacking unit: 5 pcs

NKD-JJ221V R2 Adapter Cable for Laerdal/Ambu Training Doll, requires R2Adapter cable JC-755V/K342AFor current products: TEC-5500/7700/8300Packing unit: 1 pcs

NKD-L936 Power Cable, Schuko plug, cable length: 2.0 mPacking unit: 1 pcs

NKD-POWERLINE Multiple Power Socket (4 slots), medical certifi cationFor current products: all TECPacking unit: 1 pcs

NKD-SD1GB Memory SD Card 1 GBPacking unit: 1 pcs

Y011 404617 Thermal Head Cleaner PenFor current products: all ECG/TEC/old MEB/EEG/all BSM/PVM/OPV/WEPPacking unit: 1 pcs

Page 92: accessories - nihon kohden

Acc essories for AED & Training Unit

Page 93: accessories - nihon kohden

Don�t let premature death claim the lives around youSudden Cardiac Arrest (SCA) is among the leading causes of death in the world. In SCA, the heart suddenly and unexpectedly stops functioning. When this happens, the heart is no longer able to pump blood to the rest of the body. This usually results in death if not treated within minutes.

Heavy chest pains, nausea and weakness are common symptoms of SCA. More often than not, the victim also feels an impending sense of doom refl ecting their predicament.

SCA can strike anytime and any place, and can happen to anyone.

Don�t let SCA claim lives prematurely when something can be done about it.

ACT NOW!Give every life a chance to live.

Page 94: accessories - nihon kohden

www.nihonkohden.net94

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

A strong Chain of Survival improves chance of survival

The “Chain of Survival” is a proven approach to the early treatment of sudden cardiac arrest, heart attack, stroke and any other emergency. It consists of four crucial links:

EARLY ACCESSto get help

EARLY CPRto buy time

EARLY ACLSto stabilize

EARLY DEFIBRILLATIONto restart heart

1. Early Access - to activate the Emergency Medical Services (EMS).

2. Early Cardiopulmonary Resuscitation (CPR) – to slow the rate of deterioration

of the brain and heart, and buy time to enable defi brillation.

3. Early Defi brillation – to restore to a normal heart rhythm.

4. Early Advanced Cardiac Life Support (ACLS) – to stabilise the patient.

Any delay in any of these links could potentially be fatal or decrease the chance of survival.

Most people who die of heart attacks experience irregular heartbeats known as ventricular fi brillation (VF); a condition where the heart stops circulation of blood. lf left untreated, the victim will die within minutes. By far, defi brillation (electric shock) is the only known treat-ment to revert a troubled heart from VF to its normal rhythm.

Defi brillators > Accessories for AED & Training Unit

Page 95: accessories - nihon kohden

www.nihonkohden.net95

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Importance of AED in the Chain of Survival

Automated External Defi brillator or AED is perhaps the most important link in the chain to improve the SCA victim‘s survival chances.

An AED is a device that is used to diagnose and treat potentially life thre-atening abnormal heart rhythms by providing the means to apply con-trolled electrical shocks (known as defi brillation shocks) to the heart in an attempt to stop these abnormal rhythms, thereby allowing the heart to establish again an e� ective rhythm.

It will also provide guidance by simple and clear vocal instructions to the rescuer during the rescue sequence.

Studies have shown that the time to fi rst defi brillation shock is the most crucial factor in determining survival rates for SCA*. When an AED is available, it should always be applied to the SCA victim at the earliest.

Survival rate (after 1 month)

Rehabilitation rate (after 1 month)

50,0%

0,5%

10,0%

15,0%

20,0%

25,0%

30,0%

35,0%

40,0%

45,0%

0

9,8%

43,8%

38,2%

5,6% Non use AEDUse AED

For over 90% of SCA cases, death usually occurs if without intervention. However, as many as 30-50% would likely survive if AED and CPR was administered within fi rst 5 minutes of collapse. Survival chance can be signifi cantly increased with early defi brillation.

* Report of Japan FDMA (Fire and Disaster Management Agency/2008)

For every minute of delay in giving CPR and defi brillation following collapse, the survival rate decreases by 7–10%. So, why let tragedies happen where there is prevention available now? The result of not having an AED may well be another fatal case.

Defi brillators > Accessories for AED & Training Unit

Page 96: accessories - nihon kohden

www.nihonkohden.net96

Disposable accessories are intended for single use only, on one patient, during a single examination! Do not re-use disposable accessories! Reusable accessories are intended for repeated patient use on di� erent patients during di� erent examinations. Please make sure to clean reusable accessories after each patient or

between di� erent applications to prevent or reduce the risk of cross infections!

Defi brillators > Accessories for AED & Training Unit

Accessories for AED Units

Supply CodeH324A

ModelP-530K

DescriptionDefi brillation Pads, child/adult, for use with adapter cable JC-765V/K342B, weight: 85 g ± 15 g), size: 109 mm x 15 mm (± 10 mm),conductive surface: 86.68 cm2 (±10%), cable length: 1.5 mFor current products: AED-21xxPacking unit: 1 pair

SB-210VK X212A 2-Years Standby Battery for all devices until SN: 5000For current products: AED-21xxPacking unit: 1 pcs

SB-212VK X216A 2-Years Standby Battery for all devices starting from SN: 5001For current products: AED-21xxPacking unit: 1 pcs

SB-214VK X217A 4-Years Standby Battery for all devices starting from SN: 5001For current products: AED-21xxPacking unit: 1 pcs

Y184A YC-210V AED Carrying Bag. AED usage is possible without taking out from the bag!For current products: AED-21xxPacking unit: 1 pcs

Accessories for AED Training Unit TRN-2100K

Supply CodeH326

DescriptionTraining Pads, child/adultFor current products: TRN-2100KPacking unit: 1 pair

Y262B Replacement Stickers for TRN-2100K Training PadsFor current products: TRN-2100KPacking unit: 10 pcs

Page 97: accessories - nihon kohden

ACCESSORY ORDER FORMFor your convenience we have a printable order form so that you can fax in your order directly or mail/e-mail it to us. Please make sure to fi ll out all the information requested below!

Hospital/Practice

E-Mail

Contact Person Department

Customer Code Address

ZIP City

Phone Fax

ACCESSORY ORDER FORM

Standard 3 Days 2 Days Overnight

Monthly, please contact me for more details Other

Supply Code Description Required Quantity Price each in EUR / £ Price Total in EUR / £

Send in your order today! For Germany, Austria, Switzerland and BeneluxFax: +49 (0) 33203/573-19, E-Mail: [email protected] For Spain and Portugal Fax: +34 91 300 46 76, E-Mail: [email protected] For United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]

For France Fax: +33 (0) 1 49 08 93 32, E-Mail: [email protected] Italy Fax: +39 (0) 35-232546, E-Mail: [email protected] For all other European Countries, Russia, Turkey and Israel Fax: +49 (0) 6003/827-599, E-Mail: [email protected]

www.nihonkohden.net

Page 98: accessories - nihon kohden

www.nihonkohden.net98 www.nihonkohden.net98

6124-039432 47

A052 25

A053 25

A128 25, 34

A129 25

A222 34

A226 34

A238 34

F010 28

F015 91

G203 20, 54

G204 20, 54

G207 20, 54

G210C 21, 55

G210D 20 ,54

G236 20

G250 20, 54

G271A 55

G272A 54

G272B 54

G272C 55

G278A 55

H041A 18

H043A 18

H044A 18

H044B 18

H049 18

H052A 18

H052B 18

H068A 17

H068B 17

H072 17

H312 38

H324A 96

H326 96

H327 38

JC-755V 39

JC-765V 38

K079 13

K081 13

K082 13

K093C 13

K093D 13

K093F 13

K093L 14

K096A 13

K096B 13

K097 15

K098 15

K117A 29

K117B 29

K117C 29

K118 14

K119 14

K120 47, 50

K225 50

K226 50

K227 51

K228 51

K232 52

K234 52

K332 52

K336 50, 51

K342A 39

K342B 38

K350A 52

K351A 52

K352A 50

K352B 51

K353A 50

K353B 51

K354 48

K901 48

K910A 47, 50

K910A 47, 50

K911 47, 50

K912 47

K913A 47

K915 48

K922 48

K931 58

K951 85

K952 85

K957 85

K961 77

K981 72

K984 74

K987 73

KB01A 14

KB02A 14

KB03A 14

KB04A 14

KB05A 14

KB06A 14

KB07A 14

KB08A 14

KB09A 14

KB010 14

KB012 14

KB10C 14

KB11C 14

KB12D 14

KB13B 14

KB13D 14

KB14B 14

KB15B 14

KB16B 14

KB17B 14

KB18B 14

KB19C 14

L151 52

L152 52

L153 52

L901 85

L902 85

N-00 21

N-08 21

ND-593V 42

ND-594V 42

ND-595V 42

ND-596V 42

ND-597V 42

ND-612V 42

ND-893V 41

ND-894V 41

ND-895V 41

ND-896V 41

ND-897V 41

NKD-145-2,5 26

NKD-145-6A300 26

NKD-210-10/295 25

NKD-210-5-295 25

NKD-5203201 86

NKD-63 26

NKD-A054 25

NKD-A129 26

NKD-A134A 26

NKD-A226 34

NKD-A730 25

NKD-BAG 28

NKD-BDP178NK1 86

NKD-BDP178NK4 86

NKD-BDPT-1078 86

NKD-CO2GAS 75

Index as per Supply Code

Index as per Supply Code

Supply Code page Supply Code page Supply Code page Supply Code page

Page 99: accessories - nihon kohden

www.nihonkohden.net99 www.nihonkohden.net99

NKD-CPR 89

NKD-CPR/COVER 89

NKD-DEFIBAG2 36

NKD-DEFIBAG3 36

NKD-DEFIBAG6 36

NKD-DEFIBAG83 36

NKD-ECG/TAB1 19

NKD-ECG/TAB2 19

NKD-G711 28

NKD-H/ADAPTER2 19

NKD-H405 39

NKD-H406 39

NKD-IBP/LOGICAL 86

NKD-IBP/LOGICAL2 86

NKD-IBP/LOGICAL3 87

NKD-IBP/LOGICAL4 87

NKD-IBP/NOVATRANS 87

NKD-IBP/TRANSPAC 87

NKD-IBP/TRANSTAR 87

NKD-IBP/UTAH 87

NKD-IBP/UTAH2 87

NKD-JJ221V 91

NKD-L936 28, 91

NKD-NIBP/K2 82

NKD-NIBP/K3 83

NKD-O2-CAP 75

NKD-P240A 77

NKD-P241A 77

NKD-P242B 77

NKD-P249 77

NKD-POWERLINE 28, 91

NKD-S947A 82

NKD-S947B 82

NKD-S947C 82, 83

NKD-S947D 83

NKD-S947E 83

NKD-S947F 83

NKD-S947G 83

NKD-S947H 83

NKD-SD1GB 28, 91

NKD-SIPADS 89

NKD-STPADS 89

NKD-STRAP83 36

NKD-TEMPHEARTS4009 77

NKD-TEMPHEARTS4012 77

NKD-VENTIL3 75

NKD-Z715 19

NKD-Z722 19

NKD-Z723 19

P203A 63

P203B 63

P203C 63

P203D 63

P203E 64

P203F 64

P203G 64

P203H 64

P204A 64

P204B 64

P204C 65

P204D 65

P204E 66

P204F 66

P204G 66

P204H 66

P225F 61

P225G 61

P225H 61

P228A 65

P228B 67

P229A 65

P229B 67

P259 65, 67

P263 62

P267 62

P310C 62

P311C 62

P903 72

P906 72

P907 74

P908 74

P909 73

P922A 72

P923 74

P924 73

R801 72

R804 75

R805 73

S901 79

S902 79

S903 79

S951A 81

S951B 81

S951C 81

S951D 81

S951E 81

S951F 81

SB-210VK 96

SB-212VK 96

SB-214VK 96

SB-551V 32

SB-801V 32

SC-831V 32

V921 75

V922 75

V923 75

X040 23

X041 32

X041A 23

X041B 23, 32

X060A 32

X065 23, 32

X071 23

X073 23

X077 32

X078 23

Y011 28, 91

Y095A 58

Y184A 96

Y206A 38

Y206B 39

Y262B 96

Index as per Supply Code

Index as per Supply Code

Supply Code page Supply Code page Supply Code page Supply Code page

Page 100: accessories - nihon kohden

www.nihonkohden.net100 www.nihonkohden.net100 Index as per Model Code

Index as per Model Code

404617 28, 91

490933 13

6144-000427 18

6144-011852 18

669269 13

AX-250V 38

AX-251V 39

BC-753V 52

BC-755V 52

BC-763V 50

BC-763VA 50

BC-765V 51

BC-765VA 51

BJ-831V 48

BJ-900P 48

BJ-901D 13

BJ-902D 13

BJ-903D 13

BJ-904D 15

BM-901D 15

BR-002P 52

BR-004P 52

BR-018P 50

BR-019P 50

BR-020P 51

BR-021P 51

BR-202D 14

BR-903P 47, 50

BR-906P 47

BR-906V 47

BR-912D 13

BR-913D 13

BR-913E 13

BR-913P 47, 50

BR-916P 48

BR-921D 14

C-150 20, 54

F-150M 20, 54

F-150S 21, 55

FQS50-2-100 34

FQS50-3-100 34

FQW210-10-295 25

FQW210-30-295 25

J-150 20, 54

JC-002P 52

JC-005P 50, 51

JC-761V 52

JC-762V 52

JC-763V 52

JC-855V 39

JC-865V 38

JC-906P 48

JG-900P 72

JG-920P 74

JG-970P 73

JL-550T2 58

JL-900P 58

JP-900P 85

JP-910P 85

JP-920P 85

JP-921P 85

JP-960P 85

JT-900P 77

L-150 20, 54

L-150X 20, 54

LC-S2912NK 23, 32

LCS-2012NK 23

LCT-1912ANK 23

LCT-1912NK-1 32

M-150 20

NA-0003 47

NA-0003 50

NC-124D 18

NKB-102V 32

NKB-301V 23, 32

P-511 38

P-513 38

P-530K 96

PS50-2 34

RQS50-3 25, 34

RQS63-3 25

SB-150D 23

SB-201D 23

SB-831V 32

SB-901D 23

TG-101T 72

TG-121T 74

TG-221T 73

TG-900P 72

TG-901T3 72

TG-920P 74

TG-921T3 74

TG-970P 73

TL-051S 65

TL-052S 67

TL-061S 65

TL-062S 67

TL-201T 61

TL-201T1 61

TL-220T 61

TL-271T 63, 64

TL-271T3 64, 66

TL-272T 63, 64

TL-272T3 64, 66

TL-273T 63, 65

TL-273T3 64, 66

TL-274T 63, 65

TL-274T3 64, 66

TL-630T3 62

TL-631T3 62

V-040M4 54

V-06OM6 55

V-09IO3 55

V-09OM3 54

V-120S3 55

X212A 96

X216A 96

X217A 96

YC-210V 96

YG-101T 72

YG-111T 75

YG-120T 75

YG-121T 75

YG-122T 75

YG-211T 73

YN-900P 79

YN-901P 79

YN-990P 79

YP-710T 81

YP-711T 81

YP-712T 81

YP-713T 81

YP-714T 81

YP-715T 81

YS-093P2 62

YSI-401 77

YSI-402 77

YSI-409B 77

Z-101BC 28

Z-101EA 91

ZM: S616 77

Model Code page Model Code page Model Code page Model Code page

Page 101: accessories - nihon kohden

For Germany, Austria, Switzerland and BeneluxNIHON KOHDEN EUROPE GmbH, Vertrieb Deutschland Albert-Einstein-Ring 9, 14532 Kleinmachnow, DeutschlandFax: +49 (0) 33203/573-19, E-Mail: [email protected] For Spain and Portugal NIHON KOHDEN IBERICA S.L. C/Ulises, 75A, 28043 Madrid, SpainFax: +34 91 300 46 76, E-Mail: [email protected] For United KingdomNIHON KOHDEN UNITED KINGDOM Ltd. Tolworth Tower – 19th Floor, Ewell Road, Surbiton, Surrey KT6 7EL, United KingdomFax: +44 (0) 20 83 90 46 75, E-Mail: [email protected]

For France NIHON KOHDEN FRANCE SARL 8, rue François Delage, 94230 Cachan, FranceFax: +33 (0) 1 49 08 93 32, E-Mail: [email protected] Italy NIHON KOHDEN ITALIA S.r.l. Via Fratelli Bronzetti, 28, 24124 Bergamo, ItalyFax: +39 (0) 35-232546, E-Mail: [email protected] For all other European Countries, Russia, Turkey and Israel NIHON KOHDEN EUROPE GmbHRai� eisenstraße 10, 61191 Rosbach v. d. H., GermanyFax: +49 (0) 6003/827-599, E-Mail: [email protected]

NKE-BRZ-K/A