Accessories for Agilent Automated Liquid Handling...

4
Accessories for Agilent Automated Liquid Handling Instruments Selection Guide Agilent Automated Liquid Handling Instruments provide unparalleled versatility and precision. With proven high-accuracy pipettors and flexible configurations, they offer the performance needed to scale-up applications ranging from serial dilutions to PCR and cell-based assays. A carefully designed group of accessories provide the range of tools needed by scientists and engineers to reduce manual intervention and increase throughput and walkway time when automating routine and customized applications. Highlights of the Agilent Bravo Automated Liquid Handling Platform 96 and 384 channel pipetting • 9 On deck positions Compact footprint Highlights of the Agilent Encore Multispan Liquid Handling System • 8 Individual pipetting channels provide access into vials, tubes and microtiter plates • 32 On deck positions • Built-in robotic arm with off deck reach Figure 1. The Bravo Automated Liquid Handling Platform Figure 2. The Encore Multispan Liquid Handling System Introduction

Transcript of Accessories for Agilent Automated Liquid Handling...

Page 1: Accessories for Agilent Automated Liquid Handling …hpst.cz/sites/default/files/attachments/accessories...Accessories for Agilent Automated Liquid Handling Instruments Selection Guide

Accessories for Agilent Automated Liquid Handling Instruments

Selection Guide

Agilent Automated Liquid Handling Instruments provide unparalleled versatility and precision. With proven high-accuracy pipettors and fl exible confi gurations, they offer the performance needed to scale-up applications ranging from serial dilutions to PCR and cell-based assays. A carefully designed group of accessories provide the range of tools needed by scientists and engineers to reduce manual intervention and increase throughput and walkway time when automating routine and customized applications.

Highlights of the Agilent Bravo Automated Liquid Handling Platform• 96 and 384 channel pipetting• 9 On deck positions• Compact footprint

Highlights of the Agilent Encore Multispan Liquid Handling System• 8 Individual pipetting channels provide access into vials, tubes and microtiter plates• 32 On deck positions• Built-in robotic arm with off deck reach

Figure 1. The Bravo Automated Liquid Handling Platform

Figure 2. The Encore Multispan Liquid Handling System

Introduction

Page 2: Accessories for Agilent Automated Liquid Handling …hpst.cz/sites/default/files/attachments/accessories...Accessories for Agilent Automated Liquid Handling Instruments Selection Guide

2

Accessories for the Agilent Liquid Handling Instruments

Part Number Description VWorks1

ControlTemp Range

3rd-Party Components2

BravoCompatible

EncoreMultispanCompatible

Bravo Location Guide

Communication, Input/Output, and IntegrationG5498B/G#023 Accessories Hub (Central electrical and communication connection point) Yes NA NA x NAG5498B/G#019 Slot/Shaker Card (1 per device on MTC/STC controllers) Yes NA NA x x NAG5498B/G#002 AC Relay (Powers device on/off) Yes NA NA x NAG5498B/G#022 Bravo LightCurtain (Safety) Yes NA NA NAG5498B/G#055 Risers, 146 mm No NA NA x NA16545-101 Gripper Upgrade Yes NA NA x NAIdentifi cationG5498B/G#031 Mirrored Barcode Reader (Requires serial port or accessory hub) Yes NA NA x x AllG5498B/G#573 2D Barcode Reader for Encore MS Yes NA NA xLiquid Handling Heads

Disposable-tip heads (Dispenses fl uid into selected wells simultaneously: M x N array, single columns, single rows, or single wells)G5498B/G#043 384ST 384-Barrel Disposable Tip Pipette Head Yes NA NA x NAG5498B/G#041 96ST 96-Barrel Disposable Tip Pipette Head Yes NA NA x NAG5498B/G#042 96LT 96-Barrel Disposable Tip Pipette Head Yes NA NA x NAFixed-tip (Dispense fl uid into all wells simultaneously)G5498B/G#045 384F50 Fixed Tip, Stainless, 384-Channel 50 µL Yes NA NA x NAG5498B/G#044 96F50 Fixed Tip, Stainless, 96-Channel 50 µL Yes NA NA x NAMicrochromatography, AssayMAP head (Requires G5498B/G#057, G5498B/G#058, and G5409-20025)G5498B/G#046 Bravo 96AM Head (For AssayMAP cartridges) Yes NA NA x NAPin toolsG5420B Pin Tools (Custom engineered for small nL volume transfers) Yes NA V&P Scientifi c

Pin Toolx NA

Platepads and InsertsPlatepads for microplates G5498B/G#004 Deck Platepad (Standard on Bravo) No NA NA x x AllG5498B/G#005 Deck Platepad, Short (Standard on Bravo SRT) No NA NA x x AllG5498B/G#028 Alignment Station (Passive; 384/1536 plates or ST tip boxes) No NA NA x x AllG5498B/G#032 Microplate Vacuum Alignment Station (For warped plates) Yes NA NA x AllG5498B/G#027 Agilent Vacuum Pump (ME4C/ME4C NT) Yes NA NA x x AllPlatepads for tip boxes G5409-20025 Deck Platepad, 96AM 250 µL Tip Loading Station (AssayMAP Bravo) No NA NA x AllG5498B/G#029 Tip Loading Station (Bravo SRT) No NA NA x AllG5498B/G#007 200 µL Tip Box (Legacy 200 µL tips Bravo SRT) No NA NA x AllG5498B/G#006 250 µL Tip Box (Bravo SRT) No NA NA x AllG5498B/G#028 Alignment Station (Passive; 384/1536 plates or ST tip boxes) No NA NA x x AllInsertsG5498B/G#003 Nested Rack Insert (Required when nested tips are used with ST heads) No NA NA x x AllG5550-17692 Teach Plate, HW1 (Included with all new Bravo platforms) No NA NA x AllReagent Reservoirs and Tip Wash StationsAuto-fi lling (All use pump module, except where indicated)G5498B/G#551 8 Channel Tip Wash Station No NA NA x NAG5498B/G#053 Auto Filling Reservoir (Reagent) Yes NA NA x x AllG5498B/G#052 Tip Wash Station (MicroWash Reservoir, 384-Chimney) Yes NA NA x 1,2,3G5498B/G#051 Tip Wash Station (MicroWash Reservoir, 96-Chimney) Yes NA NA x 1,2,3G5498B/G#057 96AM Tip Wash Station (Microwash Reservoir AssayMAP Head) Yes NA NA x 1,2,3G5498B/G#048 Open Bath Tray (Formerly Open Wash Res., Open Wash Station) Yes NA NA x AllPeristaltic pumps for auto-fi lling reservoirsG5498B/G#058 Pump Module 2.0 (For ALL autofi lling reservoirs and wash stations;

required for 96AM Tip Wash Station)Yes NA NA x x NA

G5498B/G#001 Pump Module Tubing Kit NA NA NA x x NAG5498B/G#030 Weigh Station (For precise liquid-level control) Yes NA NA x 1,2,3Manual Filling (Not recommended for tip washing)G5498B/G#050 Manual Fill Reservoir (Reagent, 384 well) No NA NA x AllG5498B/G#049 Manual Fill Reservoir (Reagent, 96 well) No NA NA x All

Page 3: Accessories for Agilent Automated Liquid Handling …hpst.cz/sites/default/files/attachments/accessories...Accessories for Agilent Automated Liquid Handling Instruments Selection Guide

3

Part Number Description VWorks1

ControlTemp Range

3rd-Party Components2

BravoCompatible

EncoreMultispanCompatible

Bravo Location Guide

SeparationG5498B/G#039 Vacuum Filtration Station Without Valves

(For use with Agilent vacuum pump, sold separately)Yes NA Millipore

MultiScreen HTS Vacuum Manifold

x x 1,2,3

G5498B/G#040 Vacuum Filtration Station With Valves (For use with customer-supplied house or 3rd party vacuum pump)

Yes NA Millipore MultiScreen HTS Vacuum Manifold

x 1,2,3

G5498B/G#027 Agilent Vacuum Pump (ME4C NT VARIO) Yes NA Vacuubrand ME4C/ME4C NT Vario

x x NA

G5498B/G#008 Magnetic Bead Accessory NA NA NA x x AllShaking and Temperature ControlControllers for Heating/Cooling/Shaking (Requires heating/cooling/shaking platepad)G5498B/G#016 Controller, Heating/Cooling/Shaking (For 1 device) Yes NA INHECO STC

Single TEC Controller

x x NA

G5498B/G#015 Controller, Heating/Cooling/Shaking (For up to 6 devices) Yes NA INHECO MTC Multi TEC Controller

x x NA

Platepad for Shaking (With self-contained controller featuring VWorks speed control; does not require G5498B/G#019 slot/shaker card)G5498B/G#033 Orbital Shaking Station Yes NA INHECO

Teleshake 2 mm Amplitude

x x All

G5498B/G#034 Orbital Shaking Station, High Speed Yes NA INHECO Teleshake, 3 mm Amplitude (High speed)

x x All

Platepad for Shaking and Heating G5498B/G#009 Heating Shaking Station

(Requires G5498B/G#016 or G5498B/G#015, and G5498B/G#019) Yes RT to

95 °CINHECO Teleshake 95

x x All

Platepad for Heating G5498B/G#018 Heating Station

(Requires G5498B/G#016 or G5498B/G#015, and G5498B/G#019)Yes RT to

110 °CINHECO HeatPac

x x All

Platepad for Heating/Cooling (Use Generic Nest for 14.4 mm tall plates and Custom Nest is for specialized plates; requires 146 mm risers)G5498B/G#035 PPeltier Thermal Station (& Generic Nest) for Bravo

Includes one device controller & G5498B/G#019 Slot/Shaker CardYes 4 to

110 °CINHECO CPAC Ultrafl at HT2TEC

x 4,6

G5498B/G#021 Peltier Thermal Station (& Generic Nest) for Bravo requires Controller [Includes G5498B/G#019 Slot/Shaker]

Yes 4 to 110 °C

INHECO CPAC Ultrafl at HT2TEC

x 4,6

G5498B/G#535 Peltier Thermal Station (& Generic Nest) for Encore Multispan Includes one device controller & G5498B/G#019 Slot/Shaker Card

Yes 4 to 110 °C

INHECO CPAC Ultrafl at HT2TEC

x

G5498B/G#575 Peltier Thermal Station (& Generic Nest) for Encore Multispan requires Controller [Includes G5498B/G#019 Slot/Shaker]

Yes 4 to 110 °C

INHECO CPAC Ultrafl at HT2TEC

x

G5498B/G#017 Custom Plate Nest for Thermal Station (Use with G5498B/G#12 or G5498B/G#013)

NA NA NA x x NA

G5498B/G#012 Insert, Deepwell Plate (Use with G5498B/G#017) NA NA NA x x NAG5498B/G#013 Insert, PCR Plate (Use with G5498B/G#017) NA NA NA x x NAG5498B/G#574 Thermoshake Heated/Cooling Shaking Yes 4 to

110 °CINHECOThermoshake

x NA

Recirculating Heater/ChillerG5498B/G#024 Chiller, Peltier, 400 watt

(Required for G5498B/G#036, G5498B/G#037, and G5498B/G#038)No 5 to

50 °CSolid State Cooling Systems ThermoCube

x x NA

Platepads for Heating/CoolingG5498B/G#036 Thermal Station

(Recirculator-based; short-side connectors; use with G5498B/G#024)No See

ChillerNA x x 4,5,6

7,8,9G5498B/G#037 Thermal Station

(Recirculator-based; long-side connectors; use with G5498B/G#024)No See

ChillerNA x x 1,2,3

G5498B/G#038 Thermal Station, 3-Position (Recirculator-based; use with G5498B/G#024)

No See Chiller

NA x 1,4,7 &3,6,9

Trash, Disposable TipG5498B/G#056 Deck Position Trash (Requires customer-supplied collector) No NA NA 4,6Vial & Tube Racks

Page 4: Accessories for Agilent Automated Liquid Handling …hpst.cz/sites/default/files/attachments/accessories...Accessories for Agilent Automated Liquid Handling Instruments Selection Guide

For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice.

©Agilent Technologies, Inc., 2014Published in the USA, November 3, 20145991-3294EN

Part Number Description VWorks1

ControlTemp Range

3rd-Party Components2

BravoCompatible

EncoreMultispanCompatible

Bravo Location Guide

G5498B/G#564 50mL SBS Rack for Deck Mount No NA NA x NAG5498B/G#566 15mL SBS Rack for Deck Mount No NA NA x NAG5498B/G#568 10mL SBS Rack for Deck Mount No NA NA x NAG5498B/G#569 2mL SBS Rack for Platepad No NA NA x x NAG5498B/G#570 2mL SBS Rack for Deck Mount No NA NA x NAG5498B/G#571 1.5mL SBS Rack for Platepad No NA NA x x NAG5498B/G#572 1.5mL SBS Rack for Deck Mount No NA NA x NA

1 - Agilent VWorks Automation Control Software.2 - Agilent Bravo Platform accessories may contain 3rd-party components which have been customized and optimized for use with the Bravo Platform, and which are supported by Agilent.3 - NA = Not applicable.4 - Bravo Location Guide: Accessories are compatible with certain on-deck positions on the Bravo Platform.

Agilent Liquid Handling Pipette TipsA complete range of pipette tips

is also available for use with Agilent Bravo Platform and Agilent Encore Multispan Systems.

Visit www.agilent.com/lifesciences/pipettetips for more information.

Learn Morewww.agilent.com/lifescience/automation

Find a local Agilent customer centerwww.agilent.com/chem/contactus

USA and [email protected]

[email protected]

Asia [email protected]

Figure 3. The Bravo Automated Liquid Handling Platform. Nine deck positions are available for accessories and labware.

Figure 4. The Encore Multispan Liquid Handling System.32 deck positions are available for accessories and labware.