Accendo GloGreen Digital HID (DHID) Ballast B70W-240M Electrical Test Report

1
TEST REPORT B70W-240M Item: B70W-240M PO no.: S201003051 Mains 120-240V, 50/60Hz, 70W Digital Ballast Date: Apr 16/10 Testing Environment: Lamps: SYLVANIA HPS70W Rel. Humidity: 35% Temperature: 18Conditions: Sample #1 Sample #2 Sample #3 Min Typ Max Operational Performance (V) 108 120-240 265 Operational Safety 102 120-240 276 Mains Frequecy (Hz) 45 60 66 Operation (Input) Input Power (W)120V 70 74 77 72.7 Input Power (W)240V -- -- -- 74 Power Factor 0.97 0.98 0.99 0.99 Currrent @ 120V 0.58 0.62 0.64 0.592 Currrent @ 240V 0.29 0.31 0.32 0.316 TDH (%) -- 5 10 6.3 Inrush Current @ 120V -- 10 30 <30 Inrush Current @ 240V -- 10 30 <30 Operation (Output) Operational Frequency (kHz) 80 90 100 85.36 Open-Circuit Power (W) -- 0.5 2.5 1.5 Supply Voltage (V) 40 45 50 43.7 Pulse Voltage (KV) 3 3.5 5 3.8 Start Warm Lamp (min) -- 1-5-10-15-20 20 1 Output Power (W)120V 66 69 72 66 Output Power (W)240V -- -- -- 68 Safety Aging Hours 12 12 Ta (C/F) 40/104 40/104 Tc (C/F) 70/158 70/158 Grounding 0.5Ω/25A 0.5Ω/25A Dielectric Voltage (V) 1800VAC,1S 1800VAC,1S Physical Data Dimension - Body (mm) 154x85x52m m Material Aluminium Color White Weight (kg/lbs) 1.0kg Accendo Electronics Ltd., CANADA-US E-mail: [email protected] Website: www.AccendoElectronics.com

description

Accendo commits to the success of your lighting retrofit/upgrade, or new Green lighting project with high-quality, safety approved products. Accendo products are manufactured to the utmost of quality assurance standards. All GloGreen Series Digital HID (DHID) ballasts undergo a thorough inspection before leaving the factory. The following are examples of test reports completed for the GloGreen Series 50W, 70W, 150W, 200W/250W, 400W, 575W, 600W, 750W and 1000W DHID ballasts. Each individual GloGreen Series ballast must undergo a burn-in period after final assembly to ensure the DHID ballast is operational at its intended specification. Please note, these tested GloGreen Series ballasts can operate either Metal Halide (MH) or High-Pressure Sodium (HPS) bulbs; as indicated, and with equal energy efficiency.

Transcript of Accendo GloGreen Digital HID (DHID) Ballast B70W-240M Electrical Test Report

Page 1: Accendo GloGreen Digital HID (DHID) Ballast B70W-240M Electrical Test Report

TEST REPORT B70W-240M

Item: B70W-240M PO no.: S201003051

Mains 120-240V, 50/60Hz, 70W Digital Ballast Date: Apr 16/10

Testing Environment: Lamps: SYLVANIA HPS70W

Rel. Humidity: 35% Temperature: 18℃

Conditions: Sample #1 Sample #2 Sample #3

Min Typ Max

Operational Performance (V) 108 120-240 265

Operational Safety 102 120-240 276

Mains Frequecy (Hz) 45 60 66

Operation (Input)

Input Power (W)@120V 70 74 77 72.7

Input Power (W)@240V -- -- -- 74

Power Factor 0.97 0.98 0.99 0.99

Currrent @ 120V 0.58 0.62 0.64 0.592

Currrent @ 240V 0.29 0.31 0.32 0.316

TDH (%) -- 5 10 6.3

Inrush Current @ 120V -- 10 30 <30

Inrush Current @ 240V -- 10 30 <30

Operation (Output)

Operational Frequency (kHz) 80 90 100 85.36

Open-Circuit Power (W) -- 0.5 2.5 1.5

Supply Voltage (V) 40 45 50 43.7

Pulse Voltage (KV) 3 3.5 5 3.8Start Warm Lamp (min) -- 1-5-10-15-20 20 1Output Power (W)@120V 66 69 72 66

Output Power (W)@240V -- -- -- 68

Safety

Aging Hours 12 12

Ta (C/F) 40/104 40/104

Tc (C/F) 70/158 70/158

Grounding 0.5Ω/25A 0.5Ω/25A

Dielectric Voltage (V) 1800VAC,1S 1800VAC,1S

Physical Data

Dimension - Body (mm)154x85x52m

mMaterial Aluminium

Color White

Weight (kg/lbs) 1.0kg

Accendo Electronics Ltd., CANADA-US E-mail: [email protected] Website: www.AccendoElectronics.com