Acceleration gradient limitations in room temperature and superconducting acceleration structures...

38
Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab

Transcript of Acceleration gradient limitations in room temperature and superconducting acceleration structures...

Page 1: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Acceleration gradient limitations in room temperature

and superconducting accelerationstructures

Nikolay SolyakFermilab

Page 2: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

RT Breakdown studies in recent years

• NLC/GLC and CLIC type TW and SW accelerating structures @ 11 GHz (SLAC) and 30 GHz (CERN)• Waveguide, Single cell cavities (SW, TW), • Special cavities (choke-cavity, TM01, PBG)

– Frequency dependence – Stored energy, Power and Group velocity– Pulse length dependence– Geometry (low/high impedance structure, slots, choke, phase advance, …)– Materials (Cu, CuZn, Au, Mo, Ti, AL, W, SS, …), coating– Surface preparation, Oxidation– HP processing

• Surface and data analysis, Simulations and Theoretical models (field emission models, plasma formation, pulse heating, etc…)

Aggressive R&D program to understand gradient limitations and physics of breakdown (collaboration of many institutions: SLAC,CERN,KEK,...)

Still we have no theory which can explain all data for all set of parameters and make a prediction (example: T53vg3MC (good) T26vg3 (not good))

Page 3: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

(J.P.Delahaye)

Page 4: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Test Results at 11 GHz

power fit = E30

T53VG3MC-11GHzHDS60S

Page 5: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Summary on gradient scaling (CLIC)

consttE pa 6/130~ aEBDR

For a fixed pulse length For a fixed BDR

constBDR

tE pa 530

New constrain - modified Poynting vector which is geometry independent and can be scaled among all (TW and SW) Cu structures.

SS ImRe0000 cSW

TW

SWTW

c gHEC

CHES

• A model of the breakdown trigger based on the pulsed heating of the potential breakdown site by the field emission currents

• describes both TW and SW accelerating structure experimental results• Good agreement experiments with analytical estimate

A.Grudiev, W.Wuensch

Page 6: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

TD18vg2.4 T18vg2.4 T28vg3 TD28vg3 CLIC_G

Sc=6.2MW/mm2 @ tpP=100ns

Average unloaded gradient [MV/m]

109 106 105 103 120

Prediction of average unloaded gradient at rect. pulse length of 100ns and BDR=1e-6 based on the results achieved in T53vg3MC: 102.3MV/m at 100ns and BDR=1e-6: Sc=6.2MW/mm2@100ns.

Predictions for test structures

Best tested CLIC type structure TD18vg2.4: Eacc ~ 105 MV/m at 100 ns

From Alexei Grudiev

Page 7: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

“Practical” Gradient limitations in RT accelerating structure

• Stored energy (SW), RF power and group velocity (TW)– fraction of energy dissipated in tip vs. geometry?– < 1J energy dissipated in breakdown site– In TWS power absorbed in spot, before plasma built

• Breakdown triggered by field emission - Es

– Fatigue, modification of boundaries and grains

• Magnetic pulse heating – T~ (Hs2)()1/4 (plastic

deformation limit: T~50ºC for annealed Cu and ~130ºC)

• Possible other limitations (dark current, Multipactoring, couplers, windows, etc…)

Page 8: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

• Growing tips

Page 9: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Theory of Breakdown

• A lot of experimental data is available, more will come soon– Need more statistics for each tested geometry

• Few models are presented, but non of them is able to explain all experiments and predict gradient limits – Do we need one theory to explain everything?– Few breakdown mechanisms few theories– Clear criteria to define which mechanism is dominated for

chosen parameters space

• Facts, which should be explained by theory– Breakdown in TM01 cavity (no surface electric field)– Factor of ~2 difference in electric field in low/ high impedance

structures– Gradient limitation in cavity with small gaps (choke cavity)– ….

Page 10: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

• Let’s try to scale gradient limit results obtained for room temperature structures to SC cavity:

RT: Eacc~100 MV/m (Epk~200 MV/m) at 100ns.

SC: Eacc~ 20 MV/m (Epk~40 MV/m) @ 1ms or Eacc~ 7 MV/m (Epk~14 MV/m) @ 1sec

• BDR – usually not considered for SC cavity• Frequency of SC cavity is lower stored energy higher

• Conclusion: Physics of breakdown in SRF is different

Scaling results from NC to SC structures

consttE pa 6/1

Page 11: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Achieved Limit of SRF electric field•No known theoretical limit•1990: Peak surface field ~130 MV/m in CW and 210 MV/m in 1ms

pulse. J.Delaen, K.Shepard,”Test a SC rf quadrupole device”, Appl.Phys.Lett,57 (1990)

•2007: Re-entrant cavity: Eacc= 59 MV/m (Epk=125 MV/m,Hs=206.5mT). (R.L. Geng et. al., PAC07_WEPMS006) – World record in accelerating gradient

CW 4.2 K

EP

Page 12: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

1.3 GHz cavities – 4 production batch

Page 13: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

“Practical” gradient limitations for SC cavities

• Surface magnetic field – 200 mT (absolute limit?)

• Field emission, X-ray, starts at ~ 20 MV/m

• Thermal breakdown (strong limits for F>2GHz)

• Multipactoring (in cavity or couplers)

• Medium and high field Q-slopes (cryogenic losses)

• Lorentz detuning and microphonics (frequency change)

• Quality of surface treatment and Assembly

Page 14: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

From Alex Gurevich

Page 15: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Energy gap is a function: = (T,Es)

Page 16: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Magnito-optical Imaging – A.Polyanskii & P.Lee

Page 17: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Limit in gradient and Magnetic field

Re-entrant single-cell

K. Saito

Page 18: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Pushing up SRF gradient limit

New Geometry

J.Sekutowicz, V.Shemelin, K.Saito

Page 19: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Traveling Wave Accelerating Structure

~ 25% (max 42%) higher accelerating gradient (vs. TESLA cavity)

• Shorter cells (105 deg phase advance) to improve transit-time factor

• No limitation (up to 10m) in cavity length

• Need tuning to cancel reflected wave

A.Kanareykin, N.Solyak, V.Yakovlev, P.Avrakhov

Page 20: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.
Page 21: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Field Emission

•Caused by macro-particles at the surface

•Starts typically >20 MV/m

•Exponential Q-drop

•X-ray

•Dark current

•Disappear after HPR

•Clean assembly

Page 22: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Thermal breakdown

Particle and hole on thesurface

Sub-mm size defects lead to quench Temperature Mapping

Page 23: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Hot spots ( large grain cavity )

Reduced after baking

Q-slope restored by 40 V anodization

1E+09

1E+10

1E+11

0 5 10 15 20 25 30Eacc (MV/m)

Q0

Baseline 40 V anodization1st 120C 12h bake 2nd 120C 12h bake

T = 1.7 K

1

4

7

10

13

16

19

22

25

28

31

34

S1 S

3 S5 S

7 S9 S11 S

13 S15

0

0.02

0.04

0.06

0.08

0.1

0.12

T (K)

AzimuthBottom Iris

Top Iris

Equator

Q0 = 6.1 109

Eacc = 30.3 MV/m

Large-grain single-cell

1

4

7

10

13

16

19

22

25

28

31

34

S1 S

3 S5 S

7 S9 S1

1 S1

3 S1

5

0

0.03

0.06

0.09

0.12

0.15

0.18

T (K)

AzimuthBottom Iris

Top Iris

Equator

Q0 = 2.9 109

Eacc = 24 MV/m

Large Grain : Hot SpotsLarge Grain : Hot Spots

G. Ciovati - LINAC (2006)

Page 24: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Conclusion

Page 25: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

0,..,

xHTPx

TT

x cmdiss

2,2

1RFRFmsdiss HHTRP

bsbsKRFcms TTTThHHTR ,,..,2

1 2

hk

b

Thickness

Thermal Breakdown in pure Niobium

Solution for k=const (thermal conductivity)

Page 26: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Test result of 3.9 GHz accelerating cavity

1.E+09

1.E+10

1.E+11

0 2 4 6 8 10 12 14 16 18 20

Eacc, MV/m

Q

1.45 K

1.8 K

2.0 K

1

10

100

1000

10000

2.0 3.0 4.0 5.0 6.0 7.0

Tc/T

nOhm

s

RS

BCS

3-cell cavity built at FNAL

Final cavity preparation done at FNAL (BCP,HPWR)

Residual resistance R_res ~ 6 n Achieved: H_peak = 103 mT, E_acc = 19 MV/m

(Goal: Hpeak= 68 mT, Eacc=14 MV/m)

Magnetic field is likely limited by thermal breakdown

No Field Emission Q ~ 8*10 9 at E_acc =15 MV/m

Maximum accelerating field not depend on Temp

9-cell/3.9GHz: Eacc= 21 MV/m

TESLA: Eacc= 24 MV/mH = 103 mT

No Temperature dependence – why?

Page 27: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

resc

RFlinBCSs

nlins R

H

HTRBTR

2

0,

2

,1

481,

resRF

cH

HT

linBCSs

nlins R

H

H

T

eTRBTR

c

RF

2/7

0,

27,2

2)(

4,

0,

0

232 ,/

,c

RF

b H

Hh

TkT

For 2 cases: β·h<<1 and β·h>>1 it gives:

1. Non-linear Surface Resistance

res

linbcss

nlins Rdt

thT

thTtTRBTR

0

2, cos

cossinhsin

2,

The non-linear BCS resistance (RF pair breaking) in the clean limit is given by

Where:

*P.Bauer et.all, “Discussion of possible evidence for non-linear BSC resistance in SRF cavity”, SRF 2005 workshop

TklinBCSs

beT

fATR

2

,

Δ ~1.5 meV is the superconducting energy gap

Surface Resistance used in models

Non-linear case - blue

- Linear BCS:

Page 28: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Measured values of Kapitza conductance and values used in model

2. Kapitza Resistance of Niobium surface

*A. Aizaz, “Improved Heat Transfer in SRF Cavities, NSCL, MSU, 2006** Bousson et. All, “Kapitza Conductance and Thermal Conductivity of Materials Used For SRF Cavities Fabrication”, SRF workshop, 1999

Summarized parameters a, n obtained experimentally**.

Kapitza Conductance

0,01

0,1

1

1,4 1,6 1,8 2 2,2Tb (K)

hk (W

/cm

^2/K

)Used in Model 3cellsStrained*As recieved RRR232*Bousson data**after Ti*after HT*Used in Model 9cells

Page 29: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Measured values of thermal conductivity* (left) and values used in models for 3 cells and 9 cells case(right)

* A. Aizaz, “Improved Heat Transfer in SRF Cavities, NSCL, MSU, 2006

3. Thermal Conductivity of the bulk Niobium

Thermal Conductivity Model

10

100

1000

1 10T(K)

W/mK

3 cells Cavity9 cells Cavity

Page 30: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Cavity #4 QvsE July 10 2008

1.E+08

1.E+09

1.E+10

0 2 4 6 8 10 12 14 16 18 20 22 24

Eacc, MV/m

Q

1.8K

2K

1,E+09

1,E+10

1,E+11

0 2 4 6 8 10 12 14 16 18 20Eacc, MV/m

Q

1.45 K

1.8 K

2.0 K

Example 1: 3-cell 3.9 GHz cavity

1,E+09

1,E+10

0 20 40 60 80 100 120

H surface (mT)

Q

T=1.44 KT=1.8 KT=2 K

Example 2: 9-cell 3.9 GHz cavity

1,E+09

1,E+10

0 20 40 60 80 100 120

H surface (mT)

Q

T=1.8 KT=2 K

Results for 3.9 GHz cavity

3-cell cavity

9-cell cavity

I. Gonin - FNAL

Page 31: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Multipacting

MP-exponential increase of electrons under certain resonance conditions

M.Liepe

Page 32: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Multipacting in ICHIRO cavity

Page 33: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Example: MP in HOM coupler

Gradient Limitation due to MP in HOM coupler.

Result: Coupler was destroyed

Page 34: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Reproducibility problem – Scattering of gradient

0

5

10

15

20

25

30

35

40

45

Jan-95 Jan-96 Jan-97 Jan-98 Jan-99 Jan-00 Jan-01 Jan-02 Jan-03 Jan-04 Jan-05 Jan-06

Eac

c[M

V/m

]

BCP

EP

10 per. Mov. Avg. (BCP)

10 per. Mov. Avg. (EP)

Gradients achieved over time in DESY cavities

ILC Goal

K.Saito

Page 35: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

ILC Word-wide S0 / S1 R&D program

• Aim to develop procedure which will provide 85 % acceptance yield in cavity performance– S0 – single cavity– S1 – 9-cell cavity

– Fabricate 4x4 cavities and demonstrate yield at 4x4 test each (statistics)

Page 36: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

S0 - Single-cell R&D program (KEK)

ILC BCD receipt

• final EP (~20μm) after a heavy material removal ( > 100μm).

• HPR (70kg/cm2,1hr)• Bake (120OC,48hr).

Eacc = 46.5± 8.0 MV/m (17%)

EP FLASH receipt

• EP(20μm)+EP(3μm, fresh acid)

• HPR (70kg/cm2,1hr)• Bake (120OC,48hr)

Eacc = 46.7±1.9 MV/m (4%)

Page 37: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

20 25 30 35 40 45 50 55 600.98

1

1.02

1.04

1.06

1.08

1.1

1.12

1.14

1.16

1.18

1.2

Project Cost -vs- Linac Gradient

Gradient ( MV/m)

Rela

tive C

ost

ILC Main Linac

~ Eacc2 - Cryogenic losses

~ Eacc Linac/Tunnel length

Page 38: Acceleration gradient limitations in room temperature and superconducting acceleration structures Nikolay Solyak Fermilab.

Summary

• Gradient limitation in RT structure is not fully understood yet, but…– mechanisms are identified– multi-parametric studies underway – better understanding of physics– Modeling and prediction of gradient limits in real

structure

• Gradient limitation in SC cavities– Few mechanisms are studied

• Critical magnetic field• FE, thermal breakdown, MP, Q-slope, …

– New ideas to push gradient limits• Geometry optimization (LL, Re-entrant, TW structure)• multilayer

– Surface treatment and Cleaning are the key problems in SC cavity to reach stable performance.