ABB Catalogue

6
Steel we Po r Ce ent m Pp ae mn Ce et pr Pa e M2BA M 2000 range The most widely used motors from the world leaders

Transcript of ABB Catalogue

Page 1: ABB Catalogue

Steel

we

Po

r

Ce

ent

m

Ppaer

mn

Ce

et

pr

Pae

M2BA M 2000 range

The most widely used motors from the world leaders

Page 2: ABB Catalogue

TEFC, S1 Duty

415 ± 10% V, 50 ± 5%Hz.

Combined Variation of ±10%

IP 55, IC 0141

Insulation Class F0 0Ambient 50 C (Temp. rise class B 70 C)

I = Nominal or rated currentn

2T = Nominal or rated torque in Nm T = Starting torque 2. Max. load GD has been calculated assuming load n s

T = Maximum torque T = Hot withstand time torque is proportional to square of speed.max hot

T = Cold withstand timecold

Note : Owing to continuous upgradation of our design, performance parameters and dimensions are subject to change without prior notice.

I = Starting current Note : 1. All performance figures are subject to IS tolerances.s

110

132

160

200

250

315

150

180

220

270

340

425

185

217

256

318

405

500

95.0

95.3

95.6

96.0

96.0

96.1

95.0

95.3

95.6

96.0

96.0

96.1

94.0

94.3

94.6

95.0

95.0

95.1

0.87

0.89

0.90

0.90

0.90

0.91

0.83

0.86

0.87

0.87

0.87

0.88

0.75

0.80

0.81

0.81

0.81

0.82

7.0

7.0

7.0

7.0

7.0

7.0

1.1

1.2

1.4

1.5

1.5

1.5

3.0

3.0

2.7

3.0

3.0

3.0

353

423

513

641

802

1010

875

915

1125

1275

1645

1895

45

40

50

50

60

70

91

83

98

102

115

138

5.0

5.8

7.8

10.2

17.0

23.0

2980

2980

2980

2979

2978

2978

M2BA315SMA2

M2BA315SMB2

M2BA315MLA2

M2BA315MLC2

M2BA355SMA2

M2BA355MLA2

2 Pole

Output RatedSpeed (rpm)

Frame SizeWeight

Kg

Power FactorEfficiency %I(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL

n /I Is n(Sec)

Thot(Sec)

Tcold GD

Kgm

2

2Nm

TnTorque/ /T TT Ts maxn n

110

132

160

187

200

250

315

355

150

180

220

250

270

340

425

475

190

227

267

307

329

416

530

585

95.2

95.5

95.8

95.8

96.0

96.1

96.3

96.5

95.2

95.5

95.8

95.8

96.0

96.1

96.3

96.5

94.2

94.5

94.8

94.8

95.0

95.1

95.3

95.5

0.86

0.87

0.87

0.87

0.88

0.87

0.87

0.87

0.82

0.83

0.83

0.83

0.85

0.83

0.82

0.82

0.74

0.75

0.75

0.75

0.79

0.75

0.73

0.73

6.0

6.0

6.0

6.0

6.0

6.0

6.5

6.5

2.0

2.0

2.0

2.0

2.2

2.0

2.0

1.5

2.7

2.7

2.7

2.7

2.8

2.6

3.0

2.7

707

849

1029

1202

1286

1607

2024

2280

905

960

1110

1150

1260

1620

1870

2110

34

31

34

32

36

60

70

70

70

63

70

65

75

110

120

120

9.5

10.6

13.5

15.6

17.0

26.5

33.0

40.0

1485

1485

1485

1485

1485

1486

1486

1487

M2BA315SMA4

M2BA315SMB4

M2BA315MLA4

M2BA315MLB4

M2BA315MLC4

M2BA355SMA4

M2BA355MLA4

M2BA355MLB4

4 Pole

Output RatedSpeed (rpm)

Frame SizeWeight

Kg

Power FactorEfficiency %I(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL

n /I Is n(Sec)

Thot(Sec)

Tcold GD

Kgm

2

2Nm

TnTorque/ /T TT Ts maxn n

75

90

110

132

160

200

250

315

100

120

150

180

220

270

340

425

132

158

193

228

275

343

432

550

94.2

94.5

94.6

94.9

95.2

95.5

95.6

95.6

94.2

94.5

94.6

94.9

95.2

95.5

95.6

95.6

92.2

92.5

92.6

92.9

93.2

93.5

93.6

93.6

0.85

0.84

0.84

0.85

0.85

0.85

0.85

0.82

0.81

0.79

0.79

0.80

0.80

0.80

0.80

0.77

0.72

0.70

0.70

0.71

0.71

0.71

0.71

0.68

6.0

6.5

6.5

6.5

6.5

6.5

6.5

6.5

2.0

2.3

2.3

2.3

1.8

1.9

1.9

1.9

2.5

2.7

2.7

2.7

2.6

2.7

2.7

2.7

726

870

1063

1276

1545

1929

2416

3044

860

930

1005

1240

1595

1800

1940

2040

27

21

26

24

58

60

52

52

55

43

54

50

120

115

107

107

14.2

16.7

20.0

28.2

42.0

50.5

55.0

60.24

986

988

988

988

989

990

988

988

M2BA315SMA6

M2BA315SMB6

M2BA315SMC6

M2BA315MLC6

M2BA355SMA6

M2BA355SMB6

M2BA355MLA6

M2BA355MLB6

6 Pole

Output RatedSpeed (rpm)

Frame SizeWeight

Kg

Power FactorEfficiency %I(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL

n /I Is n(Sec)

Thot(Sec)

Tcold GD

Kgm

2

2Nm

TnTorque/ /T TT Ts maxn n

55

75

90

110

132

160

200

250

75

100

120

150

180

220

270

340

101

135

162

197

239

289

385

470

93.5

94.0

94.5

94.6

94.7

95.0

95.3

95.5

93.5

94.0

94.5

94.6

94.7

95.0

95.3

95.5

91.5

92.0

92.5

92.6

92.7

93.0

93.3

93.5

0.81

0.82

0.82

0.82

0.81

0.80

0.76

0.77

0.73

0.75

0.75

0.75

0.73

0.72

0.68

0.69

0.61

0.65

0.65

0.65

0.61

0.60

0.54

0.57

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

1.7

1.8

1.9

1.8

1.5

1.8

1.7

1.5

2.5

2.5

2.5

2.5

2.3

2.5

2.6

3.0

710

968

1161

1420

1704

2065

2581

3226

830

975

1055

1125

1590

1945

2090

2100

29

30

30

24

32

40

70

70

59

61

61

49

66

82

150

150

13.0

18.8

22.0

23.6

42.0

55.0

64.2

66.0

740

740

740

740

740

740

740

740

M2BA315SMA8

M2BA315SMB8

M2BA315SMC8

M2BA315MLB8

M2BA355SMA8

M2BA355MLA8

M2BA355MLB8

M2BA355MLB8K

8 Pole

Output RatedSpeed (rpm)

Frame SizeWeight

Kg

Power FactorEfficiency %I(A) FLFLkW HP 3/4FL3/4FL 1/2FL1/2FL

n /I Is n(Sec)

Thot(Sec)

Tcold GD

Kgm

2

2Nm

TnTorque/ /T TT Ts maxn n

* On request, motors of higher kw can be offered.

Page 3: ABB Catalogue

No

te : A

ll D

ime

nsi

on

s a

re in

mm

AA

AA

BA

CB

BA

BB

CD

T

OL

.E

BE

50

8

50

8

B’

12

0

12

0

62

0

62

0

64

5

64

5

40

6

45

7

45

7

50

8

18

0

18

0

58

9

60

8

21

6

21

6

M2

02

Po

le

4-8

Po

le

2 P

ole

4-8

Po

le

65

80

65

90

m6

m6

m6

m6

14

0

17

0

14

0

17

0M

24

Ty

pe

AC

AD

EE

BE

CE

KG

D T

OL

.

M2

BA

F3

15

SM

M2

BA

F3

15

ML

64

5

64

5

F

55

7

55

7

2 P

ole

4-8

Po

le

2 P

ole

4-8

Po

le

65

80

65

90

m6

m6

m6

m6

14

0

17

0

14

0

17

0

M2

0

M2

0

M2

4

40

40

48

11

5

13

0

11

5

13

0

18

22

18

25

58

71

58

81

Ty

pe

LD

MN

PS

T

60

0

60

0

55

0

55

0

66

0

66

0

24

24

O 11

5

11

5

M2

BA

F3

15

SM

M2

BA

F3

15

ML

2 P

ole

4-8

Po

le

2 P

ole

4-8

Po

le

36

0.5

39

0.5

36

0.5

39

0.5

6 6

EC

EK

FG

GD

HH

DK

LL

DB

ea

rin

gs

OH

A

31

5

31

5

50

50

87

2

87

2

28

28

2 P

ole

4-8

Po

le

2 P

ole

4-8

Po

le

36

0.5

39

0.5

36

0.5

39

0.5

63

16

C3

63

19

C3

63

16

C3

63

19

C3

40

40

48

11

5

13

0

11

5

13

0

18

22

18

25

58

71

58

81

11

14

11

14

11

69

11

99

12

15

12

45

11

5

11

5

63

16

C3

63

16

C3

63

16

C3

63

16

C3

DN

Dim

en

sio

n D

raw

ing

M2

BA

31

5 (

Fo

ot

Mo

un

ted

)M

ou

nti

ng

De

sig

na

tio

n B

3, IM

10

01

Dim

en

sio

n D

raw

ing

M

ou

nti

ng

De

sig

na

tio

n B

5, IM

30

01

M2

BA

31

5 (

Fla

ng

e M

ou

nte

d)

Ty

pe

M2

BA

31

5S

M

M2

BA

31

5M

L

Ty

pe

M2

BA

31

5S

M

M2

BA

31

5M

L

GD

LL

BL

A

11

14

11

14

11

69

11

99

12

15

12

45

22

22

10

29

10

75

Be

ari

ng

s

63

16

C3

63

19

C3

63

16

C3

63

19

C3

63

16

C3

63

16

C3

63

16

C3

63

16

C3

DN

Page 4: ABB Catalogue

No

te : A

ll D

ime

nsi

on

s a

re in

mm

Dim

en

sio

n D

raw

ing

M2

BA

35

5 (

Fo

ot

Mo

un

ted

)D

ime

ns

ion

Dra

win

g M

2B

A3

55

(F

lan

ge

Mo

un

ted

)

2 N

os.

M1

0 E

art

hin

g S

cre

w

L

LD

Gre

ase

nip

ple

T

Gre

ase

nip

ple

O

ØP

AC

ØN-js6

E

LA

LB

EK

Te

rmin

al B

ox

for

acc

ess

orie

s(if re

qu

ire

d)

AD

ØS

054

0

22.5

ØM

±0

.3

EB

EC

F-h

9

G

GD

ØD

L

LD

Gre

ase

n

ipp

le

Gre

ase

nip

ple

EK E

BA

B B1 B2 BB

2 N

os.

M1

0 E

art

hin

g S

cre

w

Te

rmin

al B

ox

for

acc

ess

orie

s(if re

qu

ire

d)

EB

EC

HD

HA

AA

A AB

ØK

H-01

F-h

9

G

GD

ØD

C

Ty

pe

AA

AA

BA

CB

B1

BA

BB

CD

T

OL

.E

BE

M2

BA

35

5S

ML

61

0

B2

12

07

00

74

05

00

56

06

30

18

67

95

25

42

Po

le

4-8

Po

le

75

10

0

m6

m6

14

0

21

0

M2

0

M2

4

Ty

pe

AC

AD

EE

BE

CE

KG

GD

LD

T

OL

.

M2

BA

F3

55

ML

74

0

F

61

02

Po

le

4-8

Po

le

75

10

0

m6

m6

14

0

21

0

11

5

17

0

20

28

67

.5

90

12

16

15

05

15

75

M2

0

M2

4

40

48

Ty

pe

EC

EK

FG

GD

HH

DK

LL

DB

ea

rin

gs

O

M2

BA

35

5S

ML

HA

35

55

59

65

28

2 P

ole

4-8

Po

le

39

5

46

5

63

19

C3

63

22

C3

11

5

17

0

20

28

67

.5

90

12

16

15

05

15

75

13

06

31

9C

3

63

19

C3

DN

40

48

Ty

pe

LA

LB

MN

PT

Be

ari

ng

sO

S

13

65

74

06

80

80

06

31

9C

3

63

22

C3

13

06

31

9C

3

63

19

C3

DN

M2

BA

F3

55

ML

2 P

ole

4-8

Po

le6

24

25

LD

39

5

46

5

ØA

C

Page 5: ABB Catalogue

The 'M2000' Series

M2000 Motors have been engineered for the twin objective of high power 0to weight ratio and efficiency at a designed ambient of 50 C. The

performance of 'M2BA' is well ahead of relevant IEC & IS standards resulting in lower energy consumption, reduced operational costs and ultimately faster returns on investment. 'M2BA' Motors have a wide range of applications including windmill.

Heavy duty design

The electrical and mechanical design of 'M2BA' Motors offer high performance values in all the mounting arrangements, protection class and in all applications. 'M2BA' Motors have withstood the test of time and are established for reliability in stringent operating conditions like thermal power plants world wide.

Installation Flexibility

A dual mounting hole is provided for installation flexibility i.e. same housing length can be used for varied mounting applications.

IP55

'M2BA' Motors are protected against the ingress of water and dust. A high degree of protection IP 55 is a standard feature of 'M2BA' Motors. Higher degrees of protection (e.g. IP 56) can also be made available on request.

Insulation scheme

'M2BA' Motors employ a unique polyamide based Class F insulation 0scheme rated for 155 C with temperature rise limited to Class B. The

advanced insulation the 'M2000' series gives high electrical and mechanical stability. This provides a generous thermal overload margin bringing greater reliability and improves life of the motor. This can be used for such conditions as increased load, high ambient temperature and variations in voltage and frequency.

User friendly design

'M2BA' Motors have a user friendly design and less number of components leading to faster and trouble-free dismantling and assembly.

Enclosure

'M2BA' Motors use rigid cast iron / fabricated housings and are provided with integrated deeper longitudinal ribs designed to give maximum cooling surface area. Integral feet ensure that the frame is rigid and vibration resistants. These frames are treated for high corrosion resistance. Effective and robust corrosion protection means that the motor can be used in all environments.

Winding

Stator winding uses high quality enamelled wires conforming to IS:13730. The windings are reinforced in the slots with slot wedges and on the overhang with fibre glass tape. To ensure long life, the stator is impregnated with a solventless resin. Gaps between individual conductors are effectively filled with this material resulting in good thermal conductivity and superior mechanical strength. All windings are tropicalised with epoxy gelcoat and made Insensitive to moisture and micro-organisms.

Ventilation

Ventilation circuit of 'M2BA' has been optimally designed based on aerodynamic and acoustic considerations. Special design of fan blades and segmental groupings of fins in horizontal and vertical planes offer the most efficient air flow and minimum air borne noise while incurring least windage losses.

Low noise levels

'M2BA' Motors are the result of special efforts made to minimize electromagnetic, airborne and structural noise. These motors are designed for quieter operation even under abnormal load conditions.

Terminal box

The spacious terminal box makes the motor quick and easy to connect. The terminal box can be rotated so that cables can be connected from the right or the left. Further, positioning of the terminal box assembly on the side or the top can also be made available on request. Flexible orientation of the terminal box with liberal sizing for easy access are design inbuilt.

Bearings

'M2BA' Motors use appropriately selected ball bearings with high temperature grease to give increased life and reliability. For high radial loads and belt driven applications roller bearings are provided. 'M2BA' Motors are provided with regreasing facility.

Voltage ranges for extra versatility

The motors are matched to the standard voltages applicable in India i.e.415V. However, motors for voltages ranging from 220V to 660V can also be provided on request.

Frequency converter drive

'M2BA' Motors are backed by the world class technology to incorporate inherent features in the design to take care of harmonics in frequency converter and yet offer the best performance. Special attention is given to mechanical features of 'M2BA' for reliable operation at extremes of speed range in variable speed applications.

EFFICIENCY

tCompe itors

100

95

90

85

80

90 110 132 160 200 250 315kW

h%Typical efficiencyof 4-pole motors.

ABB

NOISE LEVEL

C mp itorso et

dB (A)

Distance for measurement 1m.Standard IS : 325

ABB

Comparisons 4-pole machine IEC96

94

92

90

88

86

84

80

90 110 132 160 200 250 315kW

INSULATION CLASS

Our M-2000 Motorshave insulation class and temperature rise

FB

Limit temp.

Temprise

Ambient temp.

Overloadmargin

F155°C

B130°CE

120°C5

10

15

65

50 50

7090

50

Page 6: ABB Catalogue

Regional Marketing Offices :

North

14, Mathura Road,Faridabad - 121 003 Tel: +91 129 - 2275592/9627Fax: +91 129 - 2275019

ChandigarhABB Ltd. SCO-13,14,15,3rd Floor, Sector-34A,Chandigarh-160022Tel: +91 172 2606375Fax: +91 172 2601618

JaipurTel: +91 141 2744024Fax: +91 141 2744027

LucknowTel: +91 522 2209436Fax: +91 522 2209478

LudhianaTel: +91 161 5082395Fax: +91 161 5082396

Dehradun Tel: +91 135 2760654Fax: +91 135 2760655

www.abb.co.in

South

Embassy Star, 1st FloorNo. 8, Palace RoadVasanth NagarBangalore-560 052Tel: +91 80 22949779/815Fax: +91 80 22949808

Century PlazaNo. 3C, 3D, 3F, 3rd Floor561 / 562, Anna SalaiTeynampetChennai 600 018Tel: +91 44 24340201-203Fax: +91 44 24340282

CoimbatoreTel: +91 422 2313415Fax: +91 422 2313415

HyderabadTel: +91 40 27675988Fax: +91 40 27607580

KochiTel: +91 484 3942600Resident Manager:Tel: +91 94471 37264

VisakhapatnamTel: +91 891 2538188

Cat - 03 R0 01-05-07

East

No. 9, 4th FloorLala Lajpat Rai Sarani, (Elgin Road)Kolkata 700 020Tel: +91 33 22832911/06Fax: +91 33 22892990

BhubaneshwarTel: +91 674 2541062Fax: +91 674 2540985

JamshedpurTel: +91 657 2224016Fax: +91 657 2223009

GuwhatiTel: +91 361 2133055

Central

4th & 5th Floor, Maruti Heights Aamanaka, G.E. Road Raipur - 492 099 Tel: +91 771 4701016-18 Fax: +91 771 4701019

Bhopal ABB Ltd.FF-9A, Mansarovar Commercial Complex, Hosangabad Road, Bhopal-462016Tel: +91 755 4223572 Fax: ++91 755 4253323

IndoreTel: +91 731 - 2481288

West

ABB HouseDr. S B PathBallard EstateMumbai 400 038Tel: +91 22 56318231-39Fax: +91 22 56318276-77

PuneTel: +91 20 25881503-06Fax: +91 20 56016255

VadodaraTel: +91 265 2642141-42Fax: +91 265 2638911

AhemadabadTel: +91 679 22871478

NagpurTel: +91 9822737622

ABB LimitedBU -LV Motors32, Industrial Area, N.I.T., Faridabad - 121 001 INDIA.Tel: +91 129 4023001-05Fax : +91 129 4023006