A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG...

8
Mobile Flip-Hood Generators Model MMG 45 (shown) (Pages 4–7) Advanced Features • Patented Flip-Hood/Flip-Tongue Design • Steel Skid Frame and Trailer • Models with Full Load Run Times Up to 40 Hours • Durable Industrial Powder Coat Finish Mobile Lite Generators Model MLG 25 (shown) (Pages 2–3) Advanced Features • Full Tubular Steel Frame • Durable Powder Coat Finish • Up to 48 Hours Full Load Run Time • External Convenience Outlets with MLG 15, MLG 20, MLG 25 Mobile Generators Model MMG 100 (shown) (Pages 4–7) Advanced Features • Steel Skid Frame and Trailer • Durable Industrial Powder Coat Finish • Models with Full Load Run Times in Excess of 24 Hours • Detachable Generator-Set and Trailer For more information: Call: 1-800-926-9768 Local: 920-361-4442 Fax: 920-361-2214 Visit: www.generac.com 215 Power Drive Berlin, Wisconsin 54923-2420 A Tradition Of Reliability And Innovation Mobile Power When and Where You Need It

Transcript of A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG...

Page 1: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

Mobile Flip-Hood GeneratorsModel MMG 45 (shown) (Pages 4–7)

Advanced Features

• Patented Flip-Hood/Flip-Tongue Design

• Steel Skid Frame and Trailer

• Models with Full Load Run Times Up to 40 Hours

• Durable Industrial Powder Coat Finish

Mobile Lite GeneratorsModel MLG 25 (shown) (Pages 2–3)

Advanced Features

• Full Tubular Steel Frame

• Durable Powder Coat Finish

• Up to 48 Hours Full Load Run Time

• External Convenience Outlets with MLG 15, MLG 20, MLG 25

Mobile GeneratorsModel MMG 100 (shown) (Pages 4–7)

Advanced Features

• Steel Skid Frame and Trailer

• Durable Industrial Powder Coat Finish

• Models with Full Load Run Times in Excess of 24 Hours

• Detachable Generator-Set and Trailer

For more information:

Call: 1-800-926-9768 Local: 920-361-4442 Fax: 920-361-2214 Visit: www.generac.com215 Power Drive Berlin, Wisconsin 54923-2420

A Tradition Of Reliability And InnovationMobile Power When and Where You Need It

Page 2: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

MLG 20 (shown)Also Available: MLG 15, MLG 25

Mobile Lite Generators

Tough

• Steel, lockable enclosure• Full tubular steel frame• Durable powder coat finish• Stainless steel exterior hardware

Reliable

• Key switch on single phase models• Microprocessor on three phase model• Low oil/high temp shutdowns• Start limit main breaker (single phase only)• Up to 48 hours full load run time• 2 year 2,000 hour warranty• Voltage regulation within +/- 1%

Easy to Use

• Self-priming engines• External convenience outlets with MLG 15, MLG 20, MLG 25• Individual breakers• External emergency stop switch• Three phase models also have voltage selector switch, lugs and lug box safety switch, and automatic remote start

Options

• Engine heater• Battery disconnect• Battery charger• Central lift point• Configured outlet panel• Outrigger Package• Skid-Mounted• Heated Fuel Filter• Combo hitch – 2.5" ring/ 2" ball• Pintle ring hitch 2.5" or 3" ring

2

Mobile lite generators are reliable and easy to use. Undeniably tough with rugged, powder coated tubular steel frames, automatic safety shutdowns, large fuel tanks, multiple convenience outlets and user friendly controls, the MLG line of generators offers an economical power investment.

MLG 8

Cost Effective Solution for Mobile Power

Page 3: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

20

Powder-coated Steel Enclosure Easy Access To Service Ports

Lockable Cabinet Door

External Emergency E-stop

External Outlets and Grounding Lug2 - 120V 20 Amp Duplex Outlets2 - 240V 30 Amp Twist Lock2 - 240V 50 Amp Twist Lock

Tubular Steel Frame with Removable Tongue

Lite GeneratorSpecifications

3Specifications are subject to change without notice.

MLG 8

NA

NA

NA

NA

7.3/7.3

30

6.0/6.0

25

120/240

NA

60

1.0 (1 Phase)

Marathon/ Brushless/ F

70

NA

NA

NA

105 x 68 x 56

1030 (467)

1250 (567)

Tier IV

Mitsubishi

Natural

10.5 (7.8)

58.0 (1.0)

3

1800

0.63 (2.38)

1 - 12V/440 CCA

30 (114)

48

40

None

+/-1%

2

1

NA

1 - 2200 (998)

13

None

2" Ball

MLG 15

NA

NA

NA

NA

14/14

58

13/13

54

120/240

NA

60

1.0 (1 Phase)

Marathon/ Brushless/ F

68

NA

NA

NA

105 x 68 x 56

1425 (646)

1823 (827)

Tier IV

Mitsubishi

Natural

22.3 (16.6)

107 (1.8)

4

1800

1.3 (4.92)

1 - 12V/440 CCA

56 (212)

43

70

None

+/-1%

2

2

2

1 - 2200 (998)

15

None

2" Ball

MLG 20

NA

NA

NA

NA

20/20

83

19/19

79

120/240

NA

60

1.0 (1 Phase)

Marathon/ Brushless/ F

68

NA

NA

NA

105 x 68 x 56

1455 (660)

1853 (841)

Interim Tier IV

Isuzu

Natural

32.1 (23.9)

134 (2.2)

4

1800

1.8 (6.81)

1 - 12V/720 CCA

56 (212)

31

100

None

+/-1%

2

2

2

1 - 2200 (998)

15

None

2" Ball

MLG 25

20/25

30/69

18/23

28/64

16/16

67

15/15

63

120, 139, 208, 220, 240, 277

208, 220, 440, 480

60

1.0 (1 Phase) / .8 (3 Phase)

Marathon/ Brushless/ H

68

NA

NA

NA

105 x 68 x 56

1640 (744)

2038 (924)

Interim Tier IV

Isuzu

Natural

32.1 (23.9)

134 (2.2)

4

1800

1.8 (6.81)

1 - 12V/720 CCA

56 (212)

31

90

3 Position Switch (lockable)

+/-1%

2

2

2

1 - 2200 (998)

15

None

2" Ball

Model

Output

3 Phase - Standby (kW/kVA)

Amps (480/208 V)

3 Phase - Prime (kW/kVA)

Amps (480/208 V)

1 Phase - Standby (kW/kVA)

Amps (240V)

1 Phase - Prime (kW/kVA)

Amps

AC Voltage 1-phase

AC Voltage 3-phase

Frequency Hz

Power Factor

Generator (Brand/Type/Insulation)

Sound (dB(A) 23 Feet @ prime)

Size and Weight

Skid Mounted ( l x w x h ) in

Dry Weight lb (kg)

Operating Weight lb (kg)

Trailer Mounted ( l x w x h ) (in)

Dry Weight lb (kg)

Operating Weight lb (kg)

Engine

Brand

Aspiration

HP (prime @ 1800rpm) (kW)

Displacement in3 (L)

Cylinders

Speed (rpm)

Fuel Consumed prime gph (Lph)

Battery (12 volt)

Capacities

Fuel Tank gal (L)

Approximate Run Time hrs

AC Distribution

Main Breaker

Voltage Selection

Voltage Regulation

120V - 20 amp GFCI Duplex

240V - 30 amp Twist Lock

240V - 50 amp Twist Lock

Trailer

Number of Axles & Capacity lbs (kg)

Tire Size (in)

Brakes

Hitch – Standard

Page 4: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

100

Digital ControllerEnhanced Operation and Diagnostic Display

Generator Controller

Control Panel Features

1. Control Power Switch/ON 2. Engine Start 3. LCD Display 4. Engine Stop 5. Control Power Switch/OFF 6. Alarm Cancel 7. Fault Reset 8. LED's 9. UP 10. DOWN11. Page Select 12. Enter

4

Easy Operation

MMG 25 – MMG 465

Page 5: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

Options

• Superstart• Engine heater• Battery disconnect• Tandem axle trailers• Dedicated voltage configurations• Battery charger• Buck transformer (automatic)• 36 hour full-load fuel tank• Liquid containment• Double wall tank• Interior light• Control panel light• Analog gauge control panel• 4 Position phase switch with Delta• Cam Locks• 3" Pintle ring• Brakes Surge or Electric

Mobile Generators

Tough

• Aluminum, lockable enclosure• Steel skid frame and trailer• Durable industrial powder coat finish• Stainless steel exterior hardware

Reliable

• Advanced microprocessor• Voltage regulation within +/- 1%• Models with full load run times in excess of 24 hours • Air filter condition indicator• Low coolant shutdown• 2 year 2,000 hour warranty

Easy to Use

• Voltage selector switch• Lugs and lug box safety switch• Multiple convenience outlets• External emergency stop switch• External, lockable fuel cap• Automatic remote start• Detachable generator-set and trailer• Fuel tank integrated into generator-set

MMG 100 (shown)Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465

MMG 35 (shown)Also Available: MMG 25, MMG 45, MMG 55

5

Mobile generator sets offer a wide range of power output choices from single phase 16kW – to three phase 408kW. The advanced digital controller of the genset provides simple push-button operation and easy-read system information enhancing diagnostic capabilities. The integrated large capacity fuel tanks are essential on remote site locations for reliable performance around the clock.

Mobile Power When and Where You Need It

Flip-hood/flip-tongue Mobile Generators Standard flip-hood design provides easy open access flip-hoods for routine maintenance and full service, and a large control panel access with centralized location of all electrical connections and wiring. The flip-tongue design permits cross trailer loading for truckload savings as well as added theft prevention on site.

(Four door enclosure is available, call factory for details)

Page 6: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

MMG 35

29/36

43/100

26/33

40/92

26/26

108

25/25

104

60

1 (1Ø), 0.8 (3Ø)

68

95 x 35 x 52

2050 (930)

2815 (1277)

150 x 57 x 67

2565 (1165)

3328 (1510)

Interim Tier IV

John Deere

PE4024TF281

Turbo

43 (32)

149 (2.4)

4

1800

2.6 (9.8)

106 (401)

36.9

125

+/-1%

2

NA

2

1 - 3500 (1588)

15

Surge

2" Ball

MMG 25

20/25

30/69

18/23

28/64

16/16

67

15/15

63

60

1 (1Ø), 0.8 (3Ø)

66

95 x 35 x 52

1738 (788)

2206 (1001)

150 x 57 x 67

2258 (1024)

2721 (1234)

Interim Tier IV

Isuzu

4LE1NYGV

Natural

32 (24)

134 (2.2)

4

1800

1.8 (6.8)

106 (401)

45.4

90

+/- 1%

2

NA

2

1 - 3500 (1588)

15

None

2" Ball

MMG 55

50/63

76/175

47/59

71/164

49/49

204

46/46

192

1 (1Ø), 0.8 (3Ø)

68

95 x 35 x 52

2450 (1111)

3213 (1457)

150 x 57 x 67

2970 (1347)

3733 (1693)

Tier III

John Deere

PE4024HF285

Turbo

72 (54)

149 (2.4)

4

1800

3.6 (13.6)

106 (401)

29

225

+/-1%

2

NA

2

1 - 5000 (2268)

15

Surge

2" Ball

MMG 45

35/44

53/122

33/41

49/114

33/33

138

30/30

125

60

1 (1Ø), 0.8 (3Ø)

68

95 x 35 x 52

2383 (1081)

3146 (1427)

150 x 57 x 67

2898 (1315)

3661 (1661)

Interim Tier IV

Kubota

V3600-T-E3BG

Turbo

53 (39)

221 (3.6)

4

1800

3.0 (11.4)

106 (401)

31

200

+/- 1%

2

NA

2

1 - 5000 (2268)

15

Surge

2" Ball

MMG 100

86/107

129/297

78/98

118/272

75/75

313

71/71

296

60

1 (1Ø), 0.8 (3Ø)

68

96 x 38 x 62

3402 (1543)

4361 (1978)

158 x 60 x 84

4104 (1860)

5062 (2296)

Tier III

John Deere

PE4045HF285

Turbo

122 (91)

274 (4.5)

4

1800

6.2 (23.5)

147 (556)

22

400

+/-1%

2

NA

3

1 - 6000 (2722)

15

Surge

3" Ring

Model MMG 120

120, 139, 208, 220, 240, 277

208, 220, 440, 480

Marathon / Brushless / H

3 Position Switch (Lockable)

Flip-hood Design StandardModel MMG 35 (shown)Also Available: MMG 25, MMG 45, MMG 55

Specifications for the four door enclosure design may vary from those listed above. Call factory for details

MMG 120

102/127

153/353

93/116

140/322

91/91

379

85/85

354

60

1 (1Ø), 0.8 (3Ø)

68

132 x 50 x 77

5429 (2463)

7914 (3590)

210 x 86 x 93

6825 (3096)

9310 (4223)

Tier III

John Deere

PE4045HF285

Turbo

144 (107)

275 (4.5)

4

1800

7.4 (28)

1 - 12V/1000 CCA

342 (1295)

44

450

+/-1%

2

NA

3

2 - 6000 (2722)

16

Surge

3" Ring

6

Mobile GeneratorSpecifications

Specifications are subject to change without notice.

1 - 12V/720 CCA

Model

Output

3 Phase - Standby (kW/kVA)

Amps (480/208 V)

3 Phase - Prime (kW/kVA)

Amps (480/208 V)

1 Phase - Standby (kW/kVA)

Amps (240V)

1 Phase - Prime (kW/kVA)

Amps

AC Voltage 1-phase

AC Voltage 3-phase

Frequency Hz

Power Factor

Generator (Brand/Type/Insulation)

Sound (dB(A) 23 Feet @ prime)

Size and Weight

Skid Mounted ( l x w x h ) in

Dry Weight lb (kg)

Operating Weight lb (kg)

Trailer Mounted ( l x w x h ) (in)

Dry Weight lb (kg)

Operating Weight lb (kg)

Engine

Brand

Model #

Aspiration

HP (prime @ 1800rpm) (kW)

Displacement in3 (L)

Cylinders

Speed (rpm)

Fuel Consumed prime gph (Lph)

Battery (12 volt)

Capacities

Fuel Tank gal (L)

Approximate Run Time hrs

AC Distribution

Main Breaker

Voltage Selection

Voltage Regulation

120V - 20 amp GFCI Duplex

240V - 30 amp Twist Lock

240V - 50 amp Twist Lock

Trailer

Number of Axles & Capacity lbs (kg)

Tire Size (in)

Brakes

Hitch – Standard

Page 7: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

Model MMG 405

MMG 150

127/159

191/441

116/145

174/402

114/114

475

106/106

442

60

1 (1Ø), 0.8 (3Ø)

68

132 x 50 x 77

5944 (2696)

8500 (3856)

210 x 86 x 93

7340 (3329)

9896 (4489)

Tier III

John Deere

PE4045HF285

Turbo

179 (134)

275 (4.5)

4

1800

8.5 (32.3)

342 (1295)

36

600

+/-1%

2

NA

3

2 - 6000 (2722)

16

Surge

3" Ring

MMG 185

177/221

266/613

162/202

243/561

151/151

629

137/137

571

60

1 (1Ø), 0.8 (3Ø)

68

132 x 50 x 77

6510 (2953)

9100 (4128)

210 x 86 x 93

8450 (3833)

11040 (5008)

Tier III

John Deere

PE6068HF485

Turbo

258 (193)

415 (6.8)

6

1800

12.3 (46.6)

342 (1295)

25

800

+/-1%

2

NA

3

2 - 7000 (3175)

16

Surge

3" Ring

MMG 405

358/447

538/1241

326/408

491/1132

NA

NA

NA

NA

NA

208/480

60

0.8 (3Ø)

68

175 x 60 x 96

12740 (5779)

17114 (7763)

250 x 102 x 116

15990 (7253)

20364 (9237)

Tier III

John Deere

RG6135HF485

Turbo

489 (365)

824 (13.5)

6

1800

21.1 (79.9)

616 (2332)

29

1600

+/-1%

2

NA

3

3 - 8000 (3629)

17.5

Electric

3" Ring

MMG 320

278/348

419/966

256/320

385/888

NA

NA

NA

NA

NA

208/480

60

0.8 (3Ø)

68

156 x 60 x 90

8039 (3646)

11499 (5215)

230 x 102 x 110

10912 (4949)

14372 (6519)

Tier III

John Deere

RG6090HF485

Turbo

384 (287)

548 (9.0)

6

1800

17.9 (67.8)

2 - 12V/1000 CCA

459 (1738)

24

1200

+/-1%

2

NA

3

2 - 8000 (3629)

17.5

Electric

3" Ring

MMG 235

204/255

307/708

186/233

280/647

NA

NA

NA

NA

NA

208/480

60

0.8 (3Ø)

68

132 x 50 x 77

6510 (2953)

9100 (4128)

210 x 86 x 93

8450 (3833)

11040 (5008)

Tier III

John Deere

PE6068HF485

Turbo

286 (213)

415 (6.8)

6

1800

15.2 (57.5)

342 (1295)

21

800

+/-1%

2

NA

3

2 - 7000 (3175)

16

Surge

3" Ring

MMG 465

408/510

613/1416

373/466

561/1293

NA

NA

NA

NA

NA

208/480

60

0.8 (3Ø)

68

175 x 60 x 96

12750 (5783)

17124 (7767)

250 x 102 x 116

16000 (7257)

20374 (9241)

Tier III

John Deere

RG6135HF485

Turbo

561 (419)

824 (13.5)

6

1800

26.3 (99.6)

616 (2332)

29

1600

+/-1%

2

NA

3

3 - 8000 (3629)

17.5

Electric

3" Ring

120, 139, 208, 220, 240, 277

208, 220, 440,480

3 Position Switch (lockable) Link/Reconnect BoardLink/Reconnect Board

Marathon Electric / Brushless / HMarathon Electric / Brushless / H

MMG 175

153/191

230/530

138/172

207/477

125/125

521

120/120

500

60

1.0 (1Ø), 0.8 (3Ø)

68

144 x 50 x 77

6604 (2996)

9032 (4097)

210 x 86 x 93

8000 (3629)

10428 (4730)

Interim Tier IV

John Deere

PE6068HFG94

Turbo

217 (162)

415 (6.8)

6

1800

10.9 (41.3)

342 (1295)

29

700

+/-1%

2

NA

3

2 - 6000 (2722)

16

Surge

3" Ring

Model MMG 175Interim Tier IV

Mobile GeneratorSpecifications

7Specifications are subject to change without notice.

Model

Output

3 Phase - Standby (kW/kVA)

Amps (480/208 V)

3 Phase - Prime (kW/kVA)

Amps (480/208 V)

1 Phase - Standby (kW/kVA)

Amps (240V)

1 Phase - Prime (kW/kVA)

Amps

AC Voltage 1-phase

AC Voltage 3-phase

Frequency Hz

Power Factor

Generator (Brand/Type/Insulation)

Sound (dB(A) 23 Feet @ prime)

Size and Weight

Skid Mounted ( l x w x h ) in

Dry Weight lb (kg)

Operating Weight lb (kg)

Trailer Mounted ( l x w x h ) (in)

Dry Weight lb (kg)

Operating Weight lb (kg)

Engine

Brand

Model #

Aspiration

HP (prime @ 1800rpm) (kW)

Displacement in3 (L)

Cylinders

Speed (rpm)

Fuel Consumed prime gph (Lph)

Battery (12 volt)

Capacities

Fuel Tank gal (L)

Approximate Run Time hrs

AC Distribution

Main Breaker

Voltage Selection

Voltage Regulation

120V - 20 amp GFCI Duplex

240V - 30 amp Twist Lock

240V - 50 amp Twist Lock

Trailer

Number of Axles & Capacity lbs (kg)

Tire Size (in)

Brakes

Hitch – Standard

Marathon Electric / Brushless / H

24V (2 - 12V)/1000 CCA1 - 12V/1000 CCA1 - 12V/1000 CCA

Page 8: A Tradition Of Reliability And Innovation - Faguy · 2014. 5. 6. · Also Available: MMG 120, MMG 150, MMG 185, MMG 235, MMG 320, MMG 405, MMG 465 MMG 35 (shown) Also Available: MMG

Mobile GeneratorsMMG Power Output Range:Single phase 16kW – Three phase 408kW

Mobile generators provide onsite power for construction and industry, mining, gas and oil field operations, entertainment and sporting events, municipalities, back-up or auxiliary power for schools, businesses, laboratories, hospitals, care centers and utility power during peak power needs.

MLG 25 (shown)

rev 1/12 91071

MMG 150 (shown)

A Tradition of Reliability and Innovation

For over 50 years Generac Power Systems has set the standards as a leader in the power generation industry for innovative design and premium manufacturing. Developing products that are both reliable and durable has been and continues to be a main focus for our product design.

The Generac Mobile Power line of generators exemplifies our ongoing commitment to reliability and innovation. The new diesel-powered mobile generators provide power for remote site locations and critical auxiliary power with the strength of mobility.

Dependable power; when and where you need it.

Mobile Lite GeneratorSingle phase 7.3 kW – 20kWMLG 8, MLG 15, MLG 20

Single phase 15kW – Three phase 20kWMLG 25

Mobile lite generators provide cost effective solutions for mobile power; ideal for remote powering jobsite trailers, construction and industry sites, emergency back-up power for gas/fuel stations, office or retail facilities, and power outages due to weather storms.

For more information:

Call: 1-800-926-9768 Local: 920-361-4442 Fax: 920-361-2214 Visit: www.generac.com

Manufactured by Magnum Power Products LLC215 Power Drive Berlin, Wisconsin 54923-2420