A NT N4A5 - Baker Dist...Y S O U N D R E F R ... MAX MIN LRA RLA FLA AMPS 18 208/230/1-60 253 197...
Transcript of A NT N4A5 - Baker Dist...Y S O U N D R E F R ... MAX MIN LRA RLA FLA AMPS 18 208/230/1-60 253 197...
421 21 6250 02 1/13/16Specifications subject to change without notice.
ENVIRONM
ENTA
LLY S
OU
ND R
EFRIG
ERANT
EFFICIENT 14 SEER/11.7−12.2 EER AIR CONDITIONERENVIRONMENTALLY SOUND R−410A REFRIGERANT1−1/2 THRU 5 TONS SPLIT SYSTEM208/230 Volt, 1−phase, 60 Hz208/230, 460 & 575 Volt, 3−phase, 60 HzREFRIGERATION CIRCUIT� Scroll compressors on all models� Filter−Drier supplied with every unit for field installation� Copper tube / aluminum fin coilEASY TO INSTALL AND SERVICE� Easy Access service valves on all models� External high and low refrigerant service ports� Only two screws to access control panel� Factory charged with R−410A refrigerantBUILT TO LAST� Baked−on powder coat finish over galvanized steel� Post−painted (black) coil fins� Coated, weather−resistant cabinet screws� Coated inlet grille with 3/8” (10mm) grille spacing for extra
protection (hail guard)LIMITED WARRANTY*� 10 year parts limited warranty (including compressor and
coil) with timely registration� 5 year parts limited warranty if not registered within 90
days of original installation* For owner occupied, residential applications only. See
warranty certificate for complete details and restrictions, including warranty coverage for otherapplications.
Use of the AHRI Certified TM Mark indicates amanufacturer’s participation in the program. Forverification of certification for individual products,go to www.ahridirectory.org .
ModelNumber
Size(tons)
NominalBTU/hr
Min.CircuitAmps
Max. Fuseor Breaker
Operating Dimensionsdepth x width x height in. (mm)
Ship / OperatingWeight lbs.(kg)
N4A518GKC 1−1/2 18,000 11.7 20 25−3/4 x 25−3/4 x 25(654 x 654 x 635) 145/122 (66/55)
N4A524GKC 2 24,000 14.1 20 25−3/4 x 25−3/4 x 32−5/16(654 x 654 x 821) 148/123 (67/56)
N4A530GKC 2−1/2 30,000 16.8 25 31−3/16 x 31−3/16 x 31−13/16(792 x 792 x 808) 186/151 (84/69)
N4A536GKC 3 36,000 18.1 30 31−3/16 x 31−3/16 x 35−3/16(792 x 792 x 894) 171/151(78/69)
N4A542GKC 3−1/2 42,000 22.3 35 31−3/16 x 31−3/16 x 28−7/16(792 x 792 x 722) 226/191 (103/87)
N4A548GKC 4 48,000 20.9 35 31−3/16 x 31−3/16 x 28−7/16(792 x 792 x 722) 200/182 (91/83)
N4A560GKC 5 60,000 27.5 40 31−3/16 x 31−3/16 x 31−13/16(792 x 792 x 808) 218/197 (99/89)
N4A5Performance Series
Product Specifications
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
2 421 21 6250 02Specifications subject to change without notice.
OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDEDigit Position: 1 2 3 4 5, 6 7 8 9 10 11 12
Example Part Number: N 4 A 5 18 G K C 1 0 0T = Tempstar Mainline
N = Tempstar Entry BRANDING4 = R−410A REFRIGERANTA = Air ConditionerH = Heat Pump TYPE5 = 15 SEER
NOMINAL EFFICIENCY18 = 18,000 BTUH = 1−1/2 tons24 = 24,000 BTUH = 2 tons30 = 30,000 BTUH = 2−1/2 tons36 = 36,000 BTUH = 3 tons42 = 42,000 BTUH = 3−1/2 tons48 = 48,000 BTUH = 4 tons60 = 60,000 BTUH = 5 tons NOMINAL CAPACITYA = Standard GrilleG = Coil Guard GrilleC = Coastal FEATURES
K = 208/230−1−60
H = 208/230−3−60
L = 460−3−60
S = 575−3−60 VOLTAGE
Sales Code
Engineering Revision
Extra Digit
Extra Digit
ACCESSORIES PART NUMBER IDENTIFICATION GUIDEDigit Position: 1 2 3 4 5 6, 7 8, 9 10, 11
Example Part Number: N A S A 0 0 1 01 C H
N = Non−Branded BRANDING
A = Accessory PRODUCT GROUP
S = Split System (AC & HP) KIT USAGEA = OriginalB = 2nd Generation MAJOR SERIES0 = Generic or Not Applicable
2 = R−22
4 = R−410A REFRIGERANTProduct Identifier Number
Package Quantity
Type of Kit (Example: CH = Crankcase Heater)
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 3Specifications subject to change without notice.
SD
5270−
4 R
EV
B
1.A
llow
30”
cle
aran
ce to
ser
vice
sid
e of
uni
t, 48
” ab
ove
unit,
6“
on o
ne s
ide,
12”
on
rem
aini
ng s
ides
and
24”
bet
wee
n un
its fo
r pr
oper
airf
low
.2.
Min
imum
out
door
ope
ratin
g am
bien
t in
cool
ing
mod
e is
55º
F, m
ax 1
25ºF
.
3.C
ente
r of
Gra
vity
Mod
el
Dim
ensi
ons
Inch
es (
Eng
lish)
AB
CD
EF
GK
LM
NP
Min
imum
Gro
und
Mou
ntin
g P
adS
ize
X
Min
imum
Roo
ftop
Mou
ntin
g P
adS
ize
Y
Shi
ppin
gD
imen
sion
sL
x W
x H
N4A
518G
KC
25−3
/425
3−3/
43/
44−
7/16
21−1
/49−
1/8
2−13
/16
1/2
1315−1
/49−
3/4
25−3
/4 x
25−
3/4
20−7
/16
x 20−7
/16
27−7
/8 x
27−
7/8
x 32−9
/16
N4A
524G
KC
25−3
/432−5
/16
3−3/
43/
44−
7/16
21−1
/49−
1/8
2−13
/16
1/2
13−5
/813−1
/415−1
/16
25−3
/4 x
25−
3/4
20−7
/16
x 20−7
/16
27−7
/8 x
27−
7/8
x 36−5
/8
N4A
530G
KC
31−3
/16
31−1
3/16
3−3/
43/
46−
9/16
24−1
1/16
9−1/
82−
13/1
61/
216−1
/815−1
/16
12−5
/831−3
/16
x 31−3
/16
23 x
23
33−3
/8 x
33−
3/8
x 34
N4A
536G
KC
31−3
/16
35−3
/16
3−7/
87/
86−
9/16
24−1
1/16
9−1/
82−
15/1
65/
816−1
/816−3
/814−7
/16
31−3
/16
x 31−3
/16
23 x
23
33−3
/8 x
33−
3/8
x 37−7
/16
N4A
542G
KC
31−3
/16
28−7
/16
3−7/
87/
86−
9/16
24−1
1/16
9−1/
82−
15/1
65/
815−7
/817
11−7
/831−3
/16
x 31−3
/16
23 x
23
33−3
/8 x
33−
3/8
x 30−5
/8
N4A
548G
KC
31−3
/16
28−7
/16
3−7/
87/
86−
9/16
24−1
1/16
9−1/
82−
15/1
65/
816−3
/16
16−1
/410−1
/431−3
/16
x 31−3
/16
23 x
23
33−3
/8 x
33−
3/8
x 30−5
/8
N4A
560G
KC
31−3
/16
31−1
3/16
3−7/
87/
86−
9/16
24−1
1/16
9−1/
82−
15/1
65/
815−1
/216
10−7
/831−3
/16
x 31−3
/16
23 x
23
33−3
/8 x
33−
3/8
x 34
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
4 421 21 6250 02Specifications subject to change without notice.
SD
5270−
4 R
EV
B
1.A
llow
762
mm
cle
aran
ce to
ser
vice
sid
e of
uni
t, 12
19 m
m a
bove
uni
t, 15
2 m
m o
n on
e si
de, 3
05 m
m o
n re
mai
ning
sid
es, a
nd 6
10m
m b
etw
een
units
for
prop
er a
irflo
w.
2.M
inim
um o
utdo
or o
pera
ting
ambi
ent i
n co
olin
g m
ode
is 1
3ºC
, max
52º
C.
3.C
ente
r of
Gra
vity
Mod
el
Dim
ensi
ons
mm
(S
I Met
ric)
AB
CD
EF
GK
LM
NP
Min
imum
Gro
und
Mou
ntin
gP
ad S
ize
X
Min
imum
Roo
ftop
Mou
ntin
gP
ad S
ize
Y
Shi
ppin
gD
imen
sion
sL
x W
x H
N4A
518G
KC
654
635
9519
113
540
232
7113
330
387
248
654
X 6
5451
8 x
518
708
x 70
8 x
827
N4A
524G
KC
654
821
9519
113
540
232
7113
340
337
383
654
x 65
451
8 x
518
708
x 70
8 x
827
N4A
530G
KC
792
808
9519
167
627
232
7113
410
383
321
792
x 79
258
3 x
583
847
x 84
7 x
864
N4A
536G
KC
792
894
9822
167
627
232
7516
410
416
367
792
x 79
258
3 x
583
847
x 84
7 x
951
N4A
542G
KC
792
722
9822
167
627
232
7516
403
432
302
792
x 79
258
3 x
583
847
x 84
7 x
778
N4A
548G
KC
792
722
9822
167
627
232
7516
411
413
260
792
x 79
258
3 x
583
847
x 84
7 x
778
N4A
560G
KC
792
808
9822
167
627
232
7516
394
406
276
792
x 79
258
3 x
583
847
x 84
7 x
864
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 5Specifications subject to change without notice.
PHYSICAL DATA
UNIT SIZE 18 24 30 36 42 48 60
Compressor Type Scroll
REFRIGERANT R-410A
Control TXV Hard Shutoff
Charge (lb) 3.20 (1.45) 4.60 (2.09) 5.67 (2.57) 6.40 (2.90) 7.46 (3.38) 8.31 (3.77) 9.39 (4.26)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1700 1881 2614 3365 3700 3545 3700
Motor HP 1/12 1/12 1/10 1/5 1/4 1/4 1/4
Motor RPM 1100 1100 1100 1100 1100 1110 1100
COND COIL
Face Area (Sq ft) 9.85 11.2 17.24 19.4 15.1 15.1 17.25
Fins per In. 25 25 25 25 20 20 25
Rows 1 1 1 1 2 2 2
Circuits 3 5 4 5 6 6 8
VALVE CONNECT. (In. ID)
Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor* 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8
Max Liquid Line 3/8* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See
unit Installation Instruction for proper installation.
UNIT SIZE V/PHOPER VOLTS* COMPR FAN
MCA
MAX FUSE�or CKT BRK
AMPSMAX MIN LRA RLA FLA
18
208/230/1-60 253 197
47.5 9.0 0.40 11.7 20
24 62.9 10.9 0.50 14.1 20
30 67.8 12.8 0.75 16.8 25
36 79.0 13.6 1.10 18.1 30
42 109.0 16.7 1.40 22.3 35
48 105.7 15.6 1.40 20.9 35
60 127.1 20.8 1.52 27.5 40
* Permissible limits of the voltage range at which the unit will operate satisfactorily� Time−Delay fuse.
FLA − Full Load AmpsLRA − Locked Rotor AmpsMCA − Minimum Circuit AmpsRLA − Rated Load AmpsNOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.Complies with 2010 requirements of ASHRAE Standards 90.1
A–WEIGHTED SOUND POWER (dBA)
UNIT SIZEStandard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
18 75 46.0 55.0 59.5 64.0 60.5 54.5 48.5
24 71 50.5 53.5 58.5 60.5 60.0 56.5 52.5
30 73 49.5 56.0 62.5 64.0 60.5 57.5 53.5
36 75 49.0 57.0 62.5 66.0 61.0 58.5 52.0
42 75 52.5 63.0 64.0 63.0 62.0 58.0 52.0
48 76 53.0 61.0 64.0 65.5 62.0 59.5 50.5
60 75 53.5 57.0 62.5 63.5 61.5 57.5 51.0
NOTE: Tested in compliance with AHRI 270–1995 (not listed with AHRI)
A–WEIGHTED SOUND POWER (dBA) WITH SOUND SHIELD
UNIT SIZEStandard
Rating (dBA)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
125 250 500 1000 2000 4000 8000
18 75 46.5 55.5 59.5 63.5 60.0 54.0 47.0
24 71 47.5 53.5 58.0 59.5 60.0 55.5 49.0
30 72 49.0 56.5 61.5 62.5 60.0 57.0 52.0
36 73 49.5 57.0 62.0 64.0 60.0 58.0 51.0
42 74 53.5 64.0 64.0 62.5 61.0 56.5 50.5
48 73 54.5 61.0 63.5 62.5 60.0 56.5 47.5
60 73 53.5 59.0 63.0 62.5 59.5 56.0 48.0
NOTE: Tested in compliance with AHRI 270–1995 (not listed with AHRI)
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
6 421 21 6250 02Specifications subject to change without notice.
METERING DEVICEUNIT SIZE - SERIES INDOOOR REQUIRED SUBCOOLING �F (�C)
18
TXV*
13 (7.22)
24 10 (5.56)
30 12 (6.67)
36 11 (6.11)
42 11 (6.11)
48 11 (6.11)
60 13 (7.22)
* TXV must be ordered separately when indoor coil is not equipped with a TXV. TXV must be hard–shutoff type.
REFRIGERANT CHARGE ADJUSTMENTSLiquid Line Size R-410A Charge oz/ft
3/80.60
(Factory charge for lineset = 9 oz)
5/16 0.40
1/4 0.27
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length ordiameter liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG LINE APPLICATIONSAn application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintainacceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining asystem as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor andoutdoor units.
For Air Conditioner systems, the charts below shows when an application requires a TXV and long line accessories due to linesetlength.
AC with R−410A Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required
Total Length Outdoor Unit Above or Below Indoor Unit
TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m)
AC with R−410A Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required)
Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor
1/4 + TXVNo accessories needed within al
lowed lengthsNo accessories needed within
allowed lengths175 (53.3)
5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6)
3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4)
Note: See Long Line Guideline for details
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 7Specifications subject to change without notice.
VAPOR LINE SIZING AND COOLING CAPACITY LOSSAcceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suctionline diameters shown in the chart below are acceptable for AC systems with R−410A refrigerant:
UnitNominal
Size (Btuh)
MaximumLiquid LineDiameters(In. OD)
Vapor LineDiameters(In. OD)
Cooling Capacity Loss (%)Total Equivalent Line Length ft. (m)
26-50(7.9-15.2)
51-80(15.5-24.4)
81-100(24.7-30.5)
101-125(30.8-38.1)
126-150(38.4-45.7)
151-175(46.0-53.3)
176-200(53.6-61.0)
201-225(61.3-68.6)
226-250(68.9-76.2)
181 StageAC withR-410A
3/8
1/2 1 2 3 5 6 7 8 9 11
5/8 0 1 1 1 2 2 2 3 3
3/4 0 0 0 0 1 1 1 1 1
241 StageAC withR-410A
3/8
5/8 0 1 2 2 3 3 4 5 5
3/4 0 0 1 1 1 1 1 2 2
7/8 0 0 0 0 0 1 1 1 1
301 StageAC withR-410A
3/8
5/8 1 2 3 3 4 5 6 7 8
3/4 0 0 1 1 1 2 2 2 3
7/8 0 0 0 0 1 1 1 1 1
361 StageAC withR-410A
3/8
5/8 1 2 4 5 6 8 9 10 12
3/4 0 1 1 2 2 3 3 4 4
7/8 0 0 0 1 1 1 1 2 2
421 StageAC withR-410A
3/8
3/4 0 1 2 2 3 4 4 5 6
7/8 0 0 1 1 1 2 2 2 3
1 1/8 0 0 0 0 0 0 0 0 0
481 StageAC withR-410A
3/8
3/4 0 1 2 3 4 5 5 6 7
7/8 0 0 1 1 2 2 2 3 3
1 1/8 0 0 0 0 0 0 0 1 1
601 StageAC withR-410A
3/8
3/4 1 2 4 5 6 7 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 1/8 0 0 0 1 1 1 1 1 1
Consult the Long Line Application Guideline document before purchasing/installing line sets.Applications in shaded area may have height restrictions that limit allowable total equivalent length when outdoor unit is below indoorunit.
TESTED AHRI COMBINATION RATINGSNOTE: For complete ratings information, use the AHRI website directory search: www.AHRIdirectory.org.New ratings may be listed online before Specification Sheets are updated.
UNIT SIZEINDOORMODEL
AHRI STANDARD RATINGS
FURNACE MODELCOOLING
CAPACITYFACTORYENHANCE
SEEREER
STANDARD TDR TXV
18 EA**1917AL* 17,200 TXV 14.00 12.20
24 EA**2517AL* 24,000 TXV 14.50 12.50
30 EA**3721AL* 29,600 TXV 14.50 12.50
36 EA**3721AL* 34,600 TXV 14.00 12.20
42 EA**4321AL* 40,000 TXV 14.00 12.20
48 EA**6124AL* 45,000 TXV 14.50 11.70
60 EA**6024AL* 56,500 TXV 14.00 11.70
AHRI — Air Conditioning, Heating & Refrigeration InstituteEER — Energy Efficiency Ratio − 80�F (26.6�C) indoor db/67�F (19.4�C) indoor wb & 95�F (35�C) outdoor wb.SEER — Seasonal Energy Efficiency RatioTDR — Time−Delay Relay. In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degradation in performance.
Use either the accessory Time−Delay Relay or a furnace equipped with TDR. Most ICP furnaces are equipped with TDR.NOTES:1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer
simulation procedures.3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
TESTED AHRI COMBINATION RATINGS* Or scan this QR code:NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory. www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Tempstar database: http://www.icpeqp.com/AHRIratings/ratings.aspx?Brand=Tempstar
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
8 421 21 6250 02Specifications subject to change without notice.
DE
TAIL
ED
CO
OL
ING
CA
PAC
ITIE
S#
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
518G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
24B
** In
do
or
Sec
tion
525
72
(2
2.2
)2
0.5
61
0.9
61
.11
19
.77
10
.67
1.2
51
8.9
31
0.3
51
.40
17
.98
10
.00
1.5
81
6.9
19
.62
1.7
71
5.7
09
.18
2.0
0
67
(1
9.4
)1
8.8
01
3.5
51
.12
18
.03
13
.23
1.2
61
7.2
01
2.8
91
.41
16
.29
12
.52
1.5
81
5.2
61
2.1
11
.78
14
.11
11
.66
2.0
0
63
(1
7.2
)††
17
.52
13
.07
1.1
31
6.7
51
2.7
31
.27
15
.94
12
.37
1.4
21
5.0
41
1.9
81
.59
14
.05
11
.55
1.7
81
2.9
41
1.0
82
.01
62
(1
6.7
)1
7.2
11
6.1
01
.13
16
.46
15
.76
1.2
71
5.6
71
5.4
01
.42
14
.89
14
.89
1.5
91
4.1
11
4.1
11
.78
13
.23
13
.23
2.0
0
57
(1
3.9
)1
6.8
21
6.8
21
.14
16
.21
16
.21
1.2
71
5.5
71
5.5
71
.42
14
.86
14
.86
1.5
91
4.0
81
4.0
81
.78
13
.20
13
.20
2.0
0
600
72
(2
2.2
)2
0.9
11
1.5
61
.14
20
.10
11
.27
1.2
71
9.2
31
0.9
51
.43
18
.25
10
.60
1.6
01
7.1
61
0.2
21
.80
15
.91
9.7
82
.02
67
(1
9.4
)1
9.1
41
4.5
21
.15
18
.35
14
.21
1.2
81
7.5
01
3.8
71
.44
16
.56
13
.49
1.6
11
5.5
11
3.0
81
.80
14
.33
12
.62
2.0
3
63
(1
7.2
)††
17
.86
13
.98
1.1
61
7.0
81
3.6
41
.29
16
.24
13
.28
1.4
41
5.3
21
2.8
81
.61
14
.30
12
.45
1.8
11
3.1
61
1.9
72
.03
62
(1
6.7
)1
7.6
11
7.4
41
.16
16
.94
16
.94
1.2
91
6.2
71
6.2
71
.44
15
.53
15
.53
1.6
11
4.7
01
4.7
01
.81
13
.77
13
.77
2.0
3
57
(1
3.9
)1
7.5
41
7.5
41
.16
16
.91
16
.91
1.2
91
6.2
41
6.2
41
.44
15
.50
15
.50
1.6
11
4.6
81
4.6
81
.81
13
.75
13
.75
2.0
3
675
72
(2
2.2
)2
1.1
61
2.1
51
.16
20
.33
11
.86
1.3
01
9.4
41
1.5
41
.46
18
.44
11
.19
1.6
31
7.3
21
0.8
01
.83
16
.05
10
.37
2.0
5
67
(1
9.4
)1
9.3
91
5.4
81
.17
18
.58
15
.16
1.3
11
7.7
21
4.8
11
.46
16
.77
14
.44
1.6
31
5.6
91
4.0
31
.83
14
.49
13
.56
2.0
5
63
(1
7.2
)††
18
.12
14
.87
1.1
81
7.3
11
4.5
21
.32
16
.46
14
.16
1.4
71
5.5
31
3.7
71
.64
14
.49
13
.33
1.8
41
3.3
31
2.8
42
.06
62
(1
6.7
)1
8.1
71
8.1
71
.18
17
.52
17
.52
1.3
21
6.8
21
6.8
21
.47
16
.05
16
.05
1.6
41
5.1
91
5.1
91
.83
14
.22
14
.22
2.0
6
57
(1
3.9
)1
8.1
41
8.1
41
.18
17
.49
17
.49
1.3
21
6.7
91
6.7
91
.47
16
.03
16
.03
1.6
41
5.1
71
5.1
71
.83
14
.20
14
.20
2.0
6
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
524G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
25L
17**
Ind
oo
r S
ectio
n
700
72
(2
2.2
)2
8.7
41
5.3
41
.56
27
.56
14
.90
1.7
32
6.3
31
4.4
41
.92
25
.00
13
.95
2.1
42
3.5
61
3.4
32
.40
21
.93
12
.85
2.7
0
67
(1
9.4
)2
6.2
51
8.9
71
.56
25
.16
18
.51
1.7
32
4.0
01
8.0
41
.92
22
.78
17
.53
2.1
42
1.4
21
6.9
92
.40
19
.90
16
.39
2.7
0
63
(1
7.2
)††
24
.47
18
.29
1.5
62
3.4
31
7.8
41
.73
22
.35
17
.34
1.9
22
1.1
91
6.8
32
.14
19
.88
16
.27
2.4
01
8.4
71
5.6
72
.71
62
(1
6.7
)2
3.9
62
2.4
81
.56
22
.96
22
.01
1.7
32
1.9
02
1.5
11
.92
20
.82
20
.82
2.1
41
9.7
91
9.7
92
.40
18
.66
18
.66
2.7
0
57
(1
3.9
)2
3.3
52
3.3
51
.56
22
.55
22
.55
1.7
32
1.7
02
1.7
01
.92
20
.79
20
.79
2.1
41
9.7
61
9.7
62
.40
18
.63
18
.63
2.7
0
800
72
(2
2.2
)2
9.2
21
6.1
81
.60
28
.00
15
.74
1.7
72
6.7
11
5.2
71
.96
25
.33
14
.78
2.1
82
3.8
51
4.2
62
.44
22
.16
13
.67
2.7
3
67
(1
9.4
)2
6.7
02
0.3
11
.60
25
.57
19
.85
1.7
72
4.3
71
9.3
71
.96
23
.09
18
.86
2.1
82
1.7
11
8.3
12
.44
20
.15
17
.70
2.7
4
63
(1
7.2
)††
24
.93
19
.55
1.6
02
3.8
61
9.0
81
.77
22
.73
18
.59
1.9
62
1.5
21
8.0
72
.18
20
.17
17
.49
2.4
41
8.7
21
6.8
82
.74
62
(1
6.7
)2
4.4
92
4.2
71
.60
23
.54
23
.54
1.7
72
2.6
32
2.6
31
.96
21
.65
21
.65
2.1
82
0.5
62
0.5
62
.44
19
.34
19
.34
2.7
4
57
(1
3.9
)2
4.3
62
4.3
61
.60
23
.50
23
.50
1.7
72
2.6
02
2.6
01
.96
21
.62
21
.62
2.1
82
0.5
32
0.5
32
.44
19
.32
19
.32
2.7
4
900
72
(2
2.2
)2
9.5
71
7.0
11
.63
28
.30
16
.56
1.8
02
6.9
81
6.0
92
.00
25
.56
15
.60
2.2
22
4.0
31
5.0
62
.47
22
.31
14
.47
2.7
7
67
(1
9.4
)2
7.0
42
1.6
21
.63
25
.87
21
.16
1.8
02
4.6
32
0.6
61
.99
23
.32
20
.15
2.2
22
1.9
11
9.5
92
.47
20
.32
18
.96
2.7
7
63
(1
7.2
)††
25
.27
20
.77
1.6
32
4.1
72
0.2
91
.80
23
.00
19
.80
2.0
02
1.7
61
9.2
72
.22
20
.38
18
.68
2.4
81
8.8
91
8.0
42
.78
62
(1
6.7
)2
5.2
32
5.2
31
.63
24
.32
24
.32
1.8
02
3.3
62
3.3
62
.00
22
.32
22
.32
2.2
22
1.1
92
1.1
92
.47
19
.90
19
.90
2.7
7
57
(1
3.9
)2
5.1
92
5.1
91
.63
24
.28
24
.28
1.8
02
3.3
32
3.3
32
.00
22
.30
22
.30
2.2
22
1.1
62
1.1
62
.47
19
.87
19
.87
2.7
7
See
no
tes o
n p
ag
e 7
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 9Specifications subject to change without notice.
DE
TAIL
ED
CO
OL
ING
CA
PAC
ITIE
S#
CO
NT
INU
ED
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
530G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
37L
21**
Ind
oo
r S
ectio
n
875
72
(2
2.2
)3
4.1
71
7.9
41
.96
32
.63
17
.38
2.1
63
1.0
21
6.7
92
.40
29
.33
16
.18
2.6
62
7.5
11
5.5
42
.98
25
.57
14
.86
3.3
5
67
(1
9.4
)3
1.0
22
2.1
01
.97
29
.61
21
.53
2.1
72
8.1
42
0.9
42
.40
26
.58
20
.31
2.6
62
4.9
11
9.6
62
.98
23
.13
18
.96
3.3
5
63
(1
7.2
)††
28
.77
21
.25
1.9
72
7.4
62
0.6
72
.17
26
.08
20
.08
2.4
02
4.6
21
9.4
52
.67
23
.07
18
.79
2.9
82
1.3
91
8.0
93
.35
62
(1
6.7
)2
8.1
92
6.1
51
.97
26
.92
25
.56
2.1
72
5.6
02
5.3
62
.40
24
.34
24
.34
2.6
62
3.1
12
3.1
12
.98
21
.76
21
.76
3.3
5
57
(1
3.9
)2
7.5
12
7.5
11
.97
26
.51
26
.51
2.1
72
5.4
52
5.4
52
.40
24
.30
24
.30
2.6
62
3.0
72
3.0
72
.98
21
.73
21
.73
3.3
5
1000
72
(2
2.2
)3
4.7
91
8.9
52
.01
33
.19
18
.37
2.2
13
1.5
11
7.7
82
.44
29
.73
17
.16
2.7
12
7.8
51
6.5
13
.03
25
.85
15
.82
3.4
0
67
(1
9.4
)3
1.6
12
3.6
92
.01
30
.13
23
.11
2.2
12
8.6
02
2.5
02
.44
26
.98
21
.87
2.7
12
5.2
52
1.1
93
.03
23
.42
20
.49
3.4
0
63
(1
7.2
)††
29
.34
22
.73
2.0
22
7.9
72
2.1
42
.22
26
.53
21
.53
2.4
52
5.0
12
0.8
92
.71
23
.40
20
.21
3.0
32
1.6
81
9.4
93
.40
62
(1
6.7
)2
8.8
72
8.7
12
.01
27
.71
27
.71
2.2
22
6.5
62
6.5
62
.45
25
.33
25
.33
2.7
12
4.0
02
4.0
03
.03
22
.57
22
.57
3.4
0
57
(1
3.9
)2
8.7
52
8.7
52
.01
27
.66
27
.66
2.2
22
6.5
22
6.5
22
.45
25
.29
25
.29
2.7
12
3.9
72
3.9
73
.03
22
.54
22
.54
3.4
0
1125
72
(2
2.2
)3
5.2
41
9.9
32
.06
33
.57
19
.35
2.2
63
1.8
41
8.7
42
.49
30
.02
18
.11
2.7
62
8.0
81
7.4
53
.08
26
.02
16
.75
3.4
5
67
(1
9.4
)3
2.0
52
5.2
42
.06
30
.53
24
.64
2.2
62
8.9
42
4.0
22
.49
27
.27
23
.37
2.7
62
5.5
12
2.6
93
.08
23
.63
21
.95
3.4
5
63
(1
7.2
)††
29
.77
24
.16
2.0
62
8.3
42
3.5
62
.26
26
.86
22
.94
2.4
92
5.3
02
2.2
82
.76
23
.65
21
.59
3.0
82
1.9
02
0.8
33
.45
62
(1
6.7
)2
9.8
32
9.8
32
.06
28
.67
28
.67
2.2
62
7.4
52
7.4
52
.49
26
.15
26
.15
2.7
62
4.7
42
4.7
43
.07
23
.23
23
.23
3.4
5
57
(1
3.9
)2
9.7
92
9.7
92
.06
28
.63
28
.63
2.2
62
7.4
12
7.4
12
.49
26
.11
26
.11
2.7
62
4.7
12
4.7
13
.07
23
.20
23
.20
3.4
5
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
536G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
37L
21**
Ind
oo
r S
ectio
n
1050
72
(2
2.2
)4
1.3
72
1.2
82
.29
39
.61
20
.66
2.5
73
7.3
41
9.8
72
.85
34
.80
19
.01
3.1
53
2.2
21
8.1
33
.51
29
.74
17
.32
3.9
6
67
(1
9.4
)3
8.2
42
6.6
32
.29
36
.68
26
.02
2.5
73
4.6
02
5.2
12
.84
32
.26
24
.32
3.1
32
9.8
92
3.4
23
.49
27
.60
22
.56
3.9
3
63
(1
7.2
)††
35
.82
25
.73
2.3
03
4.4
12
5.1
32
.57
32
.47
24
.32
2.8
43
0.3
02
3.4
23
.12
28
.06
22
.51
3.4
82
5.9
32
1.6
53
.92
62
(1
6.7
)3
5.2
03
1.7
52
.31
33
.85
31
.13
2.5
73
2.0
13
1.8
72
.83
30
.18
30
.18
3.1
22
8.3
32
8.3
33
.48
26
.52
26
.52
3.9
2
57
(1
3.9
)3
4.5
43
4.5
42
.31
33
.43
33
.43
2.5
83
1.9
03
1.9
02
.83
30
.14
30
.14
3.1
22
8.2
92
8.2
93
.48
26
.48
26
.48
3.9
2
1200
72
(2
2.2
)4
1.8
32
2.4
12
.34
39
.99
21
.78
2.6
33
7.6
42
0.9
82
.91
35
.04
20
.11
3.2
23
2.3
91
9.2
33
.58
29
.84
18
.39
4.0
2
67
(1
9.4
)3
8.7
62
8.4
82
.35
37
.13
27
.85
2.6
23
4.9
82
7.0
32
.90
32
.57
26
.13
3.1
93
0.1
32
5.2
13
.55
27
.79
24
.32
3.9
9
63
(1
7.2
)††
36
.39
27
.47
2.3
63
4.9
12
6.8
52
.63
32
.90
26
.03
2.8
93
0.6
42
5.1
13
.18
28
.35
24
.18
3.5
42
6.1
62
3.2
83
.98
62
(1
6.7
)3
5.9
73
5.9
72
.36
34
.75
34
.75
2.6
33
3.0
83
3.0
82
.89
31
.17
31
.17
3.1
82
9.1
92
9.1
93
.54
27
.24
27
.24
3.9
9
57
(1
3.9
)3
5.9
13
5.9
12
.36
34
.70
34
.70
2.6
33
3.0
43
3.0
42
.89
31
.13
31
.13
3.1
82
9.1
62
9.1
63
.54
27
.22
27
.22
3.9
9
1350
72
(2
2.2
)4
2.1
22
3.5
02
.40
40
.23
22
.86
2.6
93
7.8
22
2.0
52
.97
35
.16
21
.18
3.2
83
2.4
52
0.2
93
.64
29
.86
19
.44
4.0
9
67
(1
9.4
)3
9.1
33
0.2
82
.40
37
.44
29
.64
2.6
83
5.2
32
8.8
02
.96
32
.78
27
.87
3.2
53
0.3
12
6.9
33
.61
27
.93
25
.97
4.0
6
63
(1
7.2
)††
36
.81
29
.15
2.4
13
5.2
62
8.5
22
.69
33
.20
27
.67
2.9
53
0.8
92
6.7
33
.24
28
.56
25
.77
3.6
02
6.3
62
6.1
14
.04
62
(1
6.7
)3
7.0
63
7.0
62
.41
35
.74
35
.74
2.6
83
3.9
63
3.9
62
.95
31
.94
31
.94
3.2
52
9.8
42
9.8
43
.61
27
.79
27
.79
4.0
5
57
(1
3.9
)3
7.0
13
7.0
12
.41
35
.70
35
.70
2.6
83
3.9
23
3.9
22
.95
31
.90
31
.90
3.2
52
9.8
12
9.8
13
.61
27
.76
27
.76
4.0
5
See
no
tes o
n p
ag
e 7
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
10 421 21 6250 02Specifications subject to change without notice.
DE
TAIL
ED
CO
OL
ING
CA
PAC
ITIE
S#
CO
NT
INU
ED
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
542G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
43L
21**
Ind
oo
r S
ectio
n
1200
72
(2
2.2
)4
8.2
82
5.7
92
.74
46
.16
24
.99
3.0
04
3.9
82
4.1
73
.29
41
.66
23
.31
3.6
33
9.1
62
2.4
04
.04
36
.41
21
.40
4.5
0
67
(1
9.4
)4
3.8
93
1.6
92
.73
41
.97
30
.88
2.9
84
0.0
03
0.0
73
.28
37
.90
29
.20
3.6
23
5.6
02
8.2
74
.02
33
.08
27
.26
4.4
9
63
(1
7.2
)††
40
.73
30
.48
2.7
23
8.9
62
9.6
82
.98
37
.13
28
.87
3.2
73
5.1
82
8.0
13
.61
33
.05
27
.08
4.0
13
0.6
82
6.0
54
.48
62
(1
6.7
)3
9.9
93
7.4
62
.72
38
.27
36
.64
2.9
73
6.5
23
5.7
83
.27
34
.69
34
.69
3.6
13
2.9
83
2.9
84
.01
31
.05
31
.05
4.4
8
57
(1
3.9
)3
8.9
33
8.9
32
.71
37
.58
37
.58
2.9
73
6.1
53
6.1
53
.27
34
.63
34
.63
3.6
13
2.9
33
2.9
34
.01
31
.01
31
.01
4.4
8
1400
72
(2
2.2
)4
9.2
72
7.4
02
.83
47
.02
26
.58
3.0
84
4.7
32
5.7
53
.37
42
.31
24
.87
3.7
13
9.6
92
3.9
44
.11
36
.83
22
.93
4.5
8
67
(1
9.4
)4
4.8
43
4.2
62
.81
42
.81
33
.44
3.0
64
0.7
33
2.5
93
.36
38
.54
31
.71
3.7
03
6.1
53
0.7
64
.10
33
.53
29
.71
4.5
7
63
(1
7.2
)††
41
.64
32
.87
2.8
03
9.7
73
2.0
53
.05
37
.85
31
.21
3.3
53
5.8
23
0.3
33
.69
33
.59
29
.38
4.0
93
1.1
42
8.3
24
.56
62
(1
6.7
)4
1.1
34
0.7
22
.80
39
.50
39
.50
3.0
53
7.9
53
7.9
53
.35
36
.27
36
.27
3.6
93
4.4
33
4.4
34
.10
32
.35
32
.35
4.5
6
57
(1
3.9
)4
0.9
34
0.9
32
.80
39
.44
39
.44
3.0
53
7.8
93
7.8
93
.35
36
.22
36
.22
3.6
93
4.3
83
4.3
84
.10
32
.31
32
.31
4.5
6
1575
72
(2
2.2
)4
9.8
72
8.7
52
.90
47
.56
27
.92
3.1
54
5.1
82
7.0
73
.44
42
.68
26
.18
3.7
83
9.9
92
5.2
44
.18
37
.06
24
.23
4.6
5
67
(1
9.4
)4
5.4
23
6.4
22
.88
43
.33
35
.58
3.1
34
1.1
93
4.7
23
.43
38
.93
33
.82
3.7
73
6.4
93
2.8
44
.17
33
.83
31
.75
4.6
4
63
(1
7.2
)††
42
.22
34
.88
2.8
74
0.2
83
4.0
43
.12
38
.30
33
.18
3.4
23
6.2
03
2.2
73
.76
33
.93
31
.29
4.1
63
1.4
43
0.1
84
.63
62
(1
6.7
)4
2.3
84
2.3
82
.87
40
.78
40
.78
3.1
33
9.1
33
9.1
33
.42
37
.35
37
.35
3.7
73
5.4
03
5.4
04
.17
33
.21
33
.21
4.6
4
57
(1
3.9
)4
2.3
24
2.3
22
.87
40
.73
40
.73
3.1
33
9.0
83
9.0
83
.42
37
.31
37
.31
3.7
73
5.3
53
5.3
54
.17
33
.17
33
.17
4.6
4
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
Cap
acit
y M
Btu
hTo
tal
Syste
mK
W**
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
To
tal
Se
ns‡
N4A
548G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
61L
24**
Ind
oo
r S
ectio
n
1400
72
(2
2.2
)5
3.9
12
6.7
03
.12
51
.70
25
.95
3.4
64
9.2
92
5.1
43
.81
46
.61
24
.25
4.2
04
3.5
02
3.2
34
.66
39
.94
22
.07
5.2
2
67
(1
9.4
)4
9.0
73
3.0
83
.15
47
.03
32
.30
3.4
74
4.8
33
1.4
83
.81
42
.36
30
.56
4.1
93
9.5
22
9.5
24
.65
36
.26
28
.33
5.2
2
63
(1
7.2
)††
45
.60
31
.80
3.1
64
3.6
73
1.0
23
.48
41
.61
30
.19
3.8
13
9.3
12
9.2
74
.18
36
.66
28
.22
4.6
43
3.6
12
7.0
25
.22
62
(1
6.7
)4
4.8
13
9.2
63
.16
42
.96
38
.43
3.4
84
1.0
34
0.9
03
.80
39
.14
39
.14
4.1
83
6.9
93
6.9
94
.64
34
.49
34
.49
5.2
2
57
(1
3.9
)4
4.0
24
4.0
23
.16
42
.51
42
.51
3.4
84
0.9
14
0.9
13
.80
39
.08
39
.08
4.1
83
6.9
43
6.9
44
.64
34
.44
34
.44
5.2
2
1600
72
(2
2.2
)5
4.7
42
8.1
83
.20
52
.46
27
.42
3.5
44
9.9
72
6.6
03
.89
47
.17
25
.68
4.2
84
3.9
52
4.6
44
.74
40
.30
23
.48
5.3
0
67
(1
9.4
)4
9.9
13
5.4
33
.22
47
.78
34
.64
3.5
54
5.5
03
3.8
03
.89
42
.95
32
.87
4.2
74
0.0
13
1.7
94
.73
36
.67
30
.58
5.3
0
63
(1
7.2
)††
46
.41
33
.99
3.2
34
4.4
13
3.1
93
.55
42
.28
32
.35
3.8
93
9.8
93
1.4
04
.26
37
.15
30
.32
4.7
23
4.0
42
9.0
95
.30
62
(1
6.7
)4
5.9
74
5.9
73
.23
44
.36
44
.36
3.5
54
2.6
24
2.6
23
.89
40
.65
40
.65
4.2
73
8.3
53
8.3
54
.73
35
.68
35
.68
5.3
0
57
(1
3.9
)4
5.9
04
5.9
03
.23
44
.29
44
.29
3.5
54
2.5
64
2.5
63
.89
40
.59
40
.59
4.2
73
8.3
03
8.3
04
.73
35
.63
35
.63
5.3
0
1800
72
(2
2.2
)5
5.3
52
9.5
93
.27
53
.00
28
.82
3.6
25
0.4
32
7.9
93
.97
47
.55
27
.07
4.3
54
4.2
62
6.0
24
.82
40
.51
24
.83
5.3
8
67
(1
9.4
)5
0.5
13
7.7
03
.29
48
.34
36
.90
3.6
34
5.9
93
6.0
53
.97
43
.37
35
.09
4.3
54
0.3
83
3.9
84
.81
37
.00
32
.68
5.3
8
63
(1
7.2
)††
47
.02
36
.10
3.3
14
4.9
73
5.2
93
.63
42
.77
34
.42
3.9
74
0.3
33
3.4
54
.34
37
.54
32
.33
4.8
13
4.3
93
0.9
85
.38
62
(1
6.7
)4
7.5
14
7.5
13
.31
45
.80
45
.80
3.6
34
3.9
64
3.9
63
.97
41
.87
41
.87
4.3
53
9.4
43
9.4
44
.81
36
.63
36
.63
5.3
8
57
(1
3.9
)4
7.4
54
7.4
53
.31
45
.74
45
.74
3.6
34
3.9
14
3.9
13
.97
41
.82
41
.82
4.3
53
9.4
03
9.4
04
.81
36
.58
36
.58
5.3
8
See
no
tes o
n p
ag
e 7
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 11Specifications subject to change without notice.
DE
TAIL
ED
CO
OL
ING
CA
PAC
ITIE
S#
CO
NT
INU
ED
EV
AP
OR
AT
OR
AIR
CO
ND
EN
SE
R E
NT
ER
ING
AIR
TE
MP
ER
AT
UR
ES
°F
(°C
)
75 (
23.9
)85 (
29.4
)95 (
35)
105 (
40.6
)115 (
46.1
)125 (
51.7
)
CF
ME
WB
°F
(°C
)C
ap
acit
y M
Btu
h
To
tal
Syste
mK
W**
Cap
acit
y M
Btu
h
To
tal
Syste
mK
W**
Cap
acit
y M
Btu
h
To
tal
Syste
mK
W**
Cap
acit
y M
Btu
h
To
tal
Syste
mK
W**
Cap
acit
y M
Btu
h
To
tal
Syste
mK
W**
Cap
acit
y M
Btu
h
To
tal
Syste
mK
W**
N4A
560G
KA
Ou
tdo
or
Sec
tion
With
EA
*4X
60L
24**
Ind
oo
r S
ectio
n
1750
72
(2
2.2
)6
8.4
13
5.8
24
.01
65
.35
34
.67
4.3
96
2.1
53
3.4
94
.86
58
.70
32
.23
5.3
95
5.0
13
0.8
95
.96
50
.87
29
.41
6.5
5
67
(1
9.4
)6
2.2
44
4.0
44
.01
59
.41
42
.88
4.3
85
6.5
04
1.6
94
.83
53
.38
40
.43
5.3
55
0.0
03
9.0
85
.91
46
.23
37
.59
6.4
9
63
(1
7.2
)††
57
.78
42
.37
4.0
25
5.1
34
1.1
94
.37
52
.41
39
.99
4.8
14
9.5
43
8.7
55
.32
46
.39
37
.40
5.8
74
2.8
93
5.9
16
.45
62
(1
6.7
)5
6.9
25
2.1
74
.02
54
.40
50
.96
4.3
75
1.8
44
9.6
94
.81
49
.16
49
.16
5.3
24
6.6
44
6.6
45
.88
43
.73
43
.73
6.4
6
57
(1
3.9
)5
5.6
45
5.6
44
.02
53
.56
53
.56
4.3
75
1.4
35
1.4
34
.81
49
.13
49
.13
5.3
24
6.5
64
6.5
65
.88
43
.68
43
.68
6.4
6
2000
72
(2
2.2
)6
9.5
43
7.5
54
.10
66
.36
36
.39
4.4
96
3.0
43
5.1
84
.96
59
.50
33
.91
5.4
95
5.6
33
2.5
36
.06
51
.36
31
.03
6.6
6
67
(1
9.4
)6
3.3
04
6.8
34
.11
60
.35
45
.64
4.4
75
7.3
44
4.4
44
.93
54
.11
43
.16
5.4
55
0.6
14
1.7
76
.01
46
.74
40
.24
6.6
0
63
(1
7.2
)††
58
.79
44
.95
4.1
15
6.0
44
3.7
64
.47
53
.23
42
.55
4.9
15
0.2
44
1.2
75
.42
47
.00
39
.89
5.9
84
3.3
93
8.3
36
.56
62
(1
6.7
)5
8.2
55
5.8
34
.11
55
.72
55
.33
4.4
75
3.3
75
3.3
74
.91
50
.91
50
.91
5.4
34
8.1
64
8.1
65
.99
45
.09
45
.09
6.5
8
57
(1
3.9
)5
7.8
05
7.8
04
.11
55
.59
55
.59
4.4
75
3.3
05
3.3
04
.91
50
.84
50
.84
5.4
34
8.1
14
8.1
15
.99
45
.03
45
.03
6.5
8
2250
72
(2
2.2
)7
0.3
73
9.1
74
.20
67
.10
37
.99
4.5
96
3.6
73
6.7
75
.06
60
.02
35
.48
5.5
95
6.0
43
4.0
86
.17
51
.66
32
.55
6.7
6
67
(1
9.4
)6
4.0
84
9.4
74
.20
61
.08
48
.28
4.5
75
7.9
54
7.0
45
.03
54
.64
45
.73
5.5
55
1.0
74
4.3
16
.12
47
.12
42
.69
6.7
0
63
(1
7.2
)††
59
.56
47
.41
4.2
05
6.7
34
6.2
04
.56
53
.82
44
.95
5.0
15
0.7
74
3.6
55
.52
47
.44
42
.21
6.0
84
3.7
84
0.5
76
.66
62
(1
6.7
)5
9.6
95
9.6
94
.20
57
.32
57
.32
4.5
65
4.9
05
4.9
05
.02
52
.28
52
.28
5.5
34
9.4
14
9.4
16
.10
46
.17
46
.17
6.6
9
57
(1
3.9
)5
9.5
85
9.5
84
.20
57
.25
57
.25
4.5
65
4.8
35
4.8
35
.02
52
.23
52
.23
5.5
34
9.3
54
9.3
56
.10
46
.12
46
.12
6.6
9
� T
ota
l an
d s
en
sib
le c
ap
acitie
s a
re n
et
cap
acitie
s.
Blo
wer
mo
tor
heat
has b
een
su
btr
acte
d.
� S
en
sib
le c
ap
acitie
s s
ho
wn
are
based
on
80�F
(2
7�C
) en
teri
ng
air
at
the i
nd
oo
r co
il. F
or
sen
sib
le c
ap
acitie
s a
t o
ther
than
80�F
(2
7�C
), d
ed
uct
83
5 B
tuh
(2
45
kW
) p
er
10
00
CF
M (
48
0 L
/S)
of
ind
oo
r co
il air
fo
r each
deg
ree b
elo
w 8
0�F
(2
7�C
), o
r ad
d 8
35
Btu
h
(24
5 k
W)
per
10
00
CF
M (
48
0 L
/S)
of
ind
oo
r co
il air
per
deg
ree a
bo
ve 8
0�F
(2
7�C
).#
Deta
iled
co
olin
g c
ap
acitie
s a
re b
ased
on
in
do
or
an
d o
utd
oo
r u
nit a
t th
e s
am
e e
levatio
n p
er
AH
RI
sta
nd
ard
21
0/2
40
-2
00
8.
If a
dd
itio
nal
tub
ing
len
gth
an
d/o
r in
do
or
un
it i
s l
ocate
d a
bo
ve o
utd
oo
r u
nit,
a s
ligh
t vari
atio
n i
n c
ap
acity m
ay o
ccu
r.** S
yste
m k
w i
s t
ota
l o
f in
do
or
an
d o
utd
oo
r u
nit k
ilow
att
s.
�� A
t T
VA
ratin
g i
nd
oo
r co
nd
itio
n (
75�F
ed
b/6
3�F
ew
b).
All
oth
er
ind
oo
r air
tem
pera
ture
s a
re a
t 8
0�F
ed
b.
NO
TE
: W
hen
th
e r
eq
uir
ed
data
falls
betw
een
th
e p
ub
lish
ed
data
, in
terp
ola
tio
n m
ay b
e p
erf
orm
ed
. E
xtr
ap
ola
tio
n i
s n
ot
an
accep
tab
le p
ractice.
EW
B —
En
teri
ng
Wet
Bu
lb
PRODUCT SPECIFICATIONS Split System Air Conditioner: N4A5
421 21 6250 02 12Specifications subject to change without notice.
ACCESSORY USAGE GUIDELINE
Accessory
REQUIRED FORLOW−AMBIENTAPPLICATIONS
{Below 55°F (13°C)}
REQUIRED FORLONG−LINE
APPLICATIONS*
Crankcase Heater Yes YesEvaporator Freeze Thermostat Yes No
Winter Start Control Yes** No
TXV Yes YesǂHard Start Kit (Capacitor & Relay) Yes YesLow Ambient Kit (Pressure Switch) Yes No
Support Feet, 4” (102mm) tall Recommended No* Refer to the Long Line Application Guideline document.** Can only be installed in conjunction with the Low Pressure Switchǂ TXV required beyond 20 ft (6.1m) vertical separation or 50 ft (15.2) total length.
ACCESSORIES
Part Number Description Used OnModel Size
NASA001CH Crankcase Heater for Scroll Compressor (208/230 V) 42 − 60NASA003CH Crankcase Heater for Scroll Compressor (208/230 V) 18 − 36NASA001SC Start Component − PTC Device 24 − 60
NASA00201FS Evaporator Freeze Thermostat ALLNASA403PS Low Pressure Switch, AC, R−410A ALLNASA401LS Liquid Line Solenoid Valve, R−410A ALLNASA001TD Time Delay Relay, Indoor Blower ALL
NASA00201WS Winter Start Control ALLNASA001AC Anti−Cycle Timer (5 minute delay) ALLNASA404PS High Pressure Switch, AC or HP, R−410A ALLNASA005SC Hard Start Kit (Capacitor & Relay) ALLNASA401LA Low Ambient Kit (Pressure Switch), R−410A ALL
NASA00201SF Support Feet, 4” (102mm) tall (5 blocks) 18 − 36NASA001SF Support Feet, 4” (102mm) tall (4 blocks) 42 − 60NASA001SJ Sound Jacket, Compressor 18 − 48NASA003SJ Sound Jacket, Compressor 60
EBAC05TXVX TXV Kit, R−410A − 2005−2009 R−22 TXV Fancoils (air handlers) 18 − 30EBAC06TXVX TXV Kit, R−410A − 2005−2009 R−22 TXV Fancoils (air handlers) 36 − 42EBAC07TXVX TXV Kit, R−410A − 2005−2009 R−22 TXV Fancoils (air handlers) 48 − 60NAEA40501TX TXV Kit, R−410A for use with copper or tin fan coils 18 − 30NAEA40601TX TXV Kit, R−410A for use with copper or tin fan coils 36 − 42NAEA40701TX TXV Kit, R−410A for use with copper or tin fan coils 60NAEA40501TX TXV Kit, R−410A for use with aluminum fan coils 18 − 30NAEA40601TX TXV Kit, R−410A for use with aluminum fan coils 36 − 42NAEA40701TX TXV Kit, R−410A for use with aluminum fan coils 60
Copyright 2016 International Comfort Products
Lewisburg, Tennessee 37091 USA
www.GoTempstar.com