A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY
-
Upload
mastersrihari -
Category
Education
-
view
792 -
download
1
Transcript of A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY
![Page 1: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/1.jpg)
1
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
-By,
Srihari K. Malagi
Reg. No. 090907471
Sect ion : A
A Novel, low Cost, low Power
wireless CArdiAC MoNitoriNg systeM
for HeArt rAte vAriABility
![Page 2: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/2.jpg)
2
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
= 10k
0.5 Hz – 40 Hz
33k 33k
0.1u
0.1u 10k
20k
10k
20k
3.3M
3.3M
0.1u 0.1u
IC 1
IC 2
IC 3
IC 4 IC 5 IC 6
Preamplifier
InstrumentationAmplifier
High Pass FilterLow Pass FilterAmplifier
ECG LEAD II AMPLIFIER CIRCUIT:
v2
![Page 3: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/3.jpg)
3
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
0.1µF
![Page 4: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/4.jpg)
4
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
Bluetooth Modem - BlueSMiRF GoldOperating Voltage: 3.3V-6VSerial communications: 2400-115200bps
![Page 5: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/5.jpg)
5
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
Results
![Page 6: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/6.jpg)
6
Manipal Institute of Technology, ManipalManipal University
Department of Electronics and Communication Engineering
INDUSTRIAL TRAINING REPORT PRESENTATION.
1. Robert B. Northrop, Analysis and Application of Analog Electronics Circuit to BioMedical Instrumentation, CRC press.
2. Willis J Tompkins, BioMedical Digital Signal Processing, Prentice Hall.3. Rangaraj .M. Rangayyan, Biomedical Signal Processing- A Case Study Approach,Willey _Interscience
2002.4. Richard Aston, _Principle of BioMedical instruments and Measurement Publishing Company.5. Joseph J. Carr, Introduction to Biomedical Equipment Technology, 1998.6. John G. Webster, Design of Microcomputer-Based Medical Instrumentation, 1981.7. Kostelnik R., Lacko P., Perdoch M., Torork T., Ziegler J., BlueMedica: Wireless Medical Data Access
Appliance, Slovak University of Technology, 2001.8. http://faculty.etsu.edu/arnall/www/public_html/heartlung/lectures/ekg1.html9. http://faculty.etsu.edu/arnall/www/public_html/heartlung/lectures/ekg1.html10. Barry N. Feinberg Applied Clinical Engineering, 1996.11. Data sheet of AD62012. www.alldatasheet.com/datasheet-pdf/pdf/48090/AD/AD620.html13. Data sheet of 766014. www.datasheetcatalog.com/datasheets_pdf/T/C/7/6/TC7660H.shtml - 15k -
RefeRences
![Page 7: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY](https://reader035.fdocuments.in/reader035/viewer/2022071818/55aec86f1a28ab5b788b4641/html5/thumbnails/7.jpg)