A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

7
1 Manipal Institute of Technology, Manipal Manipal University Department of Electronics and Communication Engineering INDUSTRIAL TRAINING REPORT PRESENTATION. -By, Srihari K. Malagi Reg. No. 090907471 Section: A A Novel, low Cost, low Power wireless CArdiAC MoNitoriNg systeM for HeArt rAte vAriABility

Transcript of A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

Page 1: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

1

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

-By,

Srihari K. Malagi

Reg. No. 090907471

Sect ion : A

A Novel, low Cost, low Power

wireless CArdiAC MoNitoriNg systeM

for HeArt rAte vAriABility

Page 2: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

2

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

= 10k

0.5 Hz – 40 Hz

33k 33k

0.1u

0.1u 10k

20k

10k

20k

3.3M

3.3M

0.1u 0.1u

IC 1

IC 2

IC 3

IC 4 IC 5 IC 6

Preamplifier

InstrumentationAmplifier

High Pass FilterLow Pass FilterAmplifier

ECG LEAD II AMPLIFIER CIRCUIT:

v2

Page 3: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

3

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

0.1µF

Page 4: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

4

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

Bluetooth Modem - BlueSMiRF GoldOperating Voltage: 3.3V-6VSerial communications: 2400-115200bps

Page 5: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

5

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

Results

Page 6: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY

6

Manipal Institute of Technology, ManipalManipal University

Department of Electronics and Communication Engineering

INDUSTRIAL TRAINING REPORT PRESENTATION.

1. Robert B. Northrop, Analysis and Application of Analog Electronics Circuit to BioMedical Instrumentation, CRC press.

2. Willis J Tompkins, BioMedical Digital Signal Processing, Prentice Hall.3. Rangaraj .M. Rangayyan, Biomedical Signal Processing- A Case Study Approach,Willey _Interscience

2002.4. Richard Aston, _Principle of BioMedical instruments and Measurement Publishing Company.5. Joseph J. Carr, Introduction to Biomedical Equipment Technology, 1998.6. John G. Webster, Design of Microcomputer-Based Medical Instrumentation, 1981.7. Kostelnik R., Lacko P., Perdoch M., Torork T., Ziegler J., BlueMedica: Wireless Medical Data Access

Appliance, Slovak University of Technology, 2001.8. http://faculty.etsu.edu/arnall/www/public_html/heartlung/lectures/ekg1.html9. http://faculty.etsu.edu/arnall/www/public_html/heartlung/lectures/ekg1.html10. Barry N. Feinberg Applied Clinical Engineering, 1996.11. Data sheet of AD62012. www.alldatasheet.com/datasheet-pdf/pdf/48090/AD/AD620.html13. Data sheet of 766014. www.datasheetcatalog.com/datasheets_pdf/T/C/7/6/TC7660H.shtml - 15k -

RefeRences

Page 7: A Novel, Low Cost, Low Power Wireless Cardiac Monitoring System for HEART RATE VARIABILITY