A Holiday Gift Buying Guide for your GC: Latest …...A Holiday Gift Buying Guide for your GC:...

63
A Holiday Gift Buying Guide for your GC: Latest Supply Innovations Alexander Ucci Online Application Engineer November 12, 2019 November 12, 2019 1 Latest GC Supply Innovations Agilent Restricted

Transcript of A Holiday Gift Buying Guide for your GC: Latest …...A Holiday Gift Buying Guide for your GC:...

A Holiday Gift Buying Guide for your GC: Latest Supply Innovations

Alexander UcciOnline Application EngineerNovember 12, 2019

November 12, 20191 Latest GC Supply Innovations Agilent Restricted

Receive a 25% discount off any Agilent J&W GC columns, Agilent LC columns, sample preparation products, chemical standards, and your most often used GC and LC supplies.*

• Discount applies on future purchase of up to $3,000 (USD)

• Offer valid for up to 30 days after the Agilent webinar

• Use promotion code 9969

*Some restrictions apply on supplies

November 12, 20192

Exclusive Offer for Attending Agilent Chemistries Webinars

Latest GC Supply Innovations Agilent Restricted

An Overview of the Latest Supply Innovations

Gas traps

Crimpers

SeptaLinersGold sealsColumn nuts

A-line vials

Latest columnsFID jets

Sample cleanup

ADM FlowmeterStandards

November 12, 20193 Latest GC Supply Innovations Agilent Restricted

Let’s Talk About Gas Quality and Filters

• Oxygen in carrier gas is detrimental to GC/MS– Reduced response– Elevated background– Irreversible column damage– Impaired electron multiplier function– Premature filament, liner lifetime

• Use UHP carrier gases– 99.9995% or greater

• Use Gas Clean carrier gas filters

4

~5% O2

Decreased retention

Red

uced

resp

onse

GC/MS filterAgilent p/nCP17973

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Let’s Talk About Gas Quality and FiltersIf you used lower quality gases, how much O2 could the filter clean up?

5

He

Installing (and properly purging) the Gas Clean carrier gas filter lowered the O2 signal by a factor of 5.

Extracted Ion Chromatogram (EIC) for O2

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Let’s Talk About Gas Quality and FiltersIf you used lower quality gases, how much H2O could the filter clean up?

Gas Clean filter lowered the H2O signal by a factor >10.You can further increase Gas Clean and column lifetime by installing the universal filter before the Gas Clean filter.

6

HeExtracted Ion Chromatogram (EIC) for H2O

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Let’s Talk About Gas Quality and FiltersIf lower quality gases were used, how much background could the filter clean up?

• Install the Universal trap vertically – use the mounting bracket(s)• Extend the lifetime of your Gas Clean (indicating) filter and your column

7

HeBig Universal trap

GC/MS filterAgilent p/nCP17973

RMSH-2

Mounting bracketUMC-5-2

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

New Agilent A-Line Electron Crimpers and Decappers

• More vials crimped per battery charge• Increased crimping speed when compared to previous

models• Lighter weight means less hand strain and effort• OLED screen for easier viewing interface• More efficient charging• New motor life is significantly longer leading to extended

productivity

November 12, 20198

https://www.agilent.com/en/products/lab-supplies/chromatography-spectroscopy/vials-closures/crimpers-decappers-accessories

Latest GC Supply Innovations Agilent Restricted

• Choose high-quality vials and caps– Poorly constructed vial septa siloxanes bleed peaks

– Low-quality vial leach contaminants into sample

– Choose the right cap/septa for your solvent

9

Vials

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

ADM Flow Meter: Easy No-Return Recalibration

10

• Replaceable calibration cartridge

• Automatic notification of cartridge replacement

• Ergonomic and robust design

• Universal 3AA or USB power

• USB connects to Web interface for added functionality

• Easy to view OLED Screen

• Kickstand

Technical overview 5991-7685EN

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

If your target ions are buried beneath matrix peaks, it might be time to trim the column or do sample cleanup

The Matrix

500 ppb ethenoproxin black tea

10 ppb linalool in shampoo

(or improve your sample cleanup)

November 12, 201911 Latest GC Supply Innovations Agilent Restricted

How Did it Become Contaminated in the First Place?

12 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

November 12, 2019

Bond Elut Solid Phase Extraction cartridges and plates

Captiva EMR-Lipid filtration cartridges and plates

Captiva syringe filters

Offline Options for Sample Matrix Removal

QuEChERS

Filter vials

13

Synthetic Chem Elut S

Latest GC Supply Innovations Agilent Restricted

• Environmental analyses of water samples• Odor analyses (ppt)• Flavor analyses of food products• Forensic analyses of arson/explosives samples• Toxicology analyses: blood alcohol or drugs in

urine/serum• Surfactants, other industrial applications

• Trace analysis in food• Drugs and pharmaceuticals• Herbicides/pesticides• Medical diagnostics• Trace impurities in polymers and solid samples• Solvent residues in raw materials• Explosives

Solid Phase Microextraction (SPME)

14

SPME fibers SPME arrows

SPME Fiber and Arrow Offering from Agilent

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Polycyclic aromatic hydrocarbons (PAHs) are a large class of organic compounds containing two or more fused aromatic rings. PAHs are considered compounds of concern by every environmental organization; their concentration in water is strictly regulated.

15

5994-1301EN

Examination of Lower Molecular Weight PAHs in Drinking Water Using Agilent PDMS SPME Fibers

SIM chromatogram of naphthalenes with PDMS fibers (black trace = 100 µm; green trace = 30 µm; blue trace = 7 µm)

SIM chromatogram of fluoranthene and pyrene with PDMS fibers (black trace = 100 µm; green trace = 30 µm; blue trace = 7 µm)

6x10

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

2

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

3

3.1

3.2

3.3

3.4

3.5

3.6

3.7+EI SIM(128.0) SIM CTC_100PDMS_PAH_25uL_SIM_REP007.D

8.786

Counts vs. Acquisition Time (min)

8.7 8.75 8.8 8.85 8.9 8.95 9 9.05 9.1 9.15 9.2 9.25 9.3 9.35 9.4 9.45 9.5 9.55 9.6 9.65 9.7 9.75 9.8 9.85

4x10

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

2

2.2

2.4

2.6

2.8

3

3.2

3.4

3.6

3.8

4

+EI SIM(202.0) SIM CTC_30PDMS_PAH_25uL_SIM_REP007.D

15.088

15.669

Counts vs. Acquisition Time (min)

15 15.05 15.1 15.15 15.2 15.25 15.3 15.35 15.4 15.45 15.5 15.55 15.6 15.65 15.7 15.75

Naphthalene1-Methylnaphthalene

2-Methylnaphthalene FluoranthenePyrene

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Liquid/Liquid Extraction (LLE)

• LLE has been successfully used as a method of sample preparation for many years.

• It separates the more organic solvent soluble compounds from the more water-soluble compounds using water immiscible organic solvents.

• It can remove many interfering substances like salts• Modulating pH can selectively extract or eliminate specific

compound types.

16 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Drawbacks of Liquid/Liquid Extraction

• LLE does have drawbacks– Inconsistent results from one analyst to another

• Shaking time• Shaking motion• Determination of where to cut between layers

– Emulsions– Labor intensive– Quite tedious with small sample sizes (<5 mL)– Challenging with large numbers of samples– Difficult to automate for large numbers of samples

How many of these problems can be fixed with Solid Supported Liquid Extraction?

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201917

Load

Add solvent

Gravity elute

Add aqueous sample

Hold 5 min

1. Add aqueous sample to SLE sorbent2. Wait 5 minutes3. Elute with water immiscible solvent

How Does SLE Work?

18 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

• There are two types of SLE media– Diatomaceous earth (DE) based products like our Chem Elut brand of SLE products

• A mined fossil diatom material, which is heterogeneous and inconsistent from one mine to the next

– Synthetic media we use in Chem Elut S• Controlled synthesis to be consistent batch after batch

What is SLE Sorbent?

Diatomaceous Earth

in Chem Elut

Synthetic SLE sorbent

× Naturally occurring; mined

× Broad particle size distribution

× Supplier reliability issues

× Poor lot-to-lot consistency

Large scale synthesis

Narrow particle size distribution

Reliable supplier Controlled manufacturing

19 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

0

20

40

60

80

100

120

Recovery (30 µg/mL; n = 3), 87-119% Chem Elut S 5 mL Chem Elut S 10 mL Chem Elut S 20 mL

0.01.02.03.04.05.06.07.08.09.0

10.0Reproducibility (30 µg/mL; n = 3), RSD 0.4-8.2%

Chem Elut S – 15 Minute Hold TimeLarge scale format comparison with aromatic amines

20

5994-0951EN

Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

Enhanced Matrix Removal: Agilent Captiva EMR-Lipid

Free fatty acids

Phospholipids

Triglycerides

EMR-Lipid sorbent technology effectively traps lipids through two mechanisms:• Size exclusion – unbranched hydrocarbon chains (lipids)

enter the sorbent; bulky analytes do not

• Sorbent chemistry – lipid chains that enter the sorbent are trapped by hydrophobic interactions

Analyte

Lipid

EMR sorbent

November 12, 2019 Latest GC Supply Innovations Agilent Restricted21

Determination of 19 Polycyclic Aromatic Hydrocarbon Compounds in Salmon and Beef

22

Using Captiva EMR-Lipid cleanup by GC/MS/MS

5994-0553EN

Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

Captiva EMR-Lipid Cleanup Improves Analytes S/N Ratio and Integration Accuracy on GC/MS(/MS)

Pesticide

+ MRM (151.0 -> 79.1) AV MBPI-a-CD C2 spike 50ppb-1.D

Acquisition Time (m

12.7 12.8 12.9 13 13.1 13.2 13.3 13.4 13.5 13.6

Coun

ts 4x10

-0.2

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

2

2.2

2.4

2.6

13.163 min.

+ MRM (151.0 -> 79.1) AV Z-Sep+ C5 spike 50ppb-1.D

Acquisition Time (m

12.7 12.8 12.9 13 13.1 13.2 13.3 13.4 13.5 13.6

Coun

ts 5x10

-0.1

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

1.6

13.163 min.

+ MRM (183.1 -> 168.1) AV MBPI-a-CD C2 spike 50ppb-1.D

Acquisition Time (m

20.4 20.5 20.6 20.7 20.8 20.9 21 21.1 21.2

Coun

ts 4x10

-0.25

0

0.25

0.5

0.75

1

1.25

1.5

1.75

2

2.25

2.5

2.75

3

3.25

3.5

3.75

4

4.25

4.5

4.75

520.788 min.

+ MRM (183.1 -> 168.1) AV Fatty dSPE spike 50ppb-1R.D

Acquisition Time (m

20.4 20.5 20.6 20.7 20.8 20.9 21 21.1 21.2

Coun

ts 4x10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

5.5

6

6.5

20.833 min.

+ MRM (183.1 -> 168.1) AV Z-Sep+ C5 spike 50ppb-1.D

Acquisition Time (m

20.4 20.5 20.6 20.7 20.8 20.9 21 21.1 21.2

Coun

ts 4x10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

5.5

6

6.5

20.819 min.

Captan Permethrin

EMR-Lipidcleanup

Zirconia sorbentcleanup

C18/PSAcleanup

Deltamethrin

+ MRM (181.0 -> 152.1) AV a-CD pow C3 spike 50ppb-1 .D

Acquisition Time (m

22.2 22.3 22.4 22.5 22.6 22.7 22.8 22.9 23

Coun

ts 4x10

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

1.6

1.722.628 min.

Ratio = 169.4 (488.3 %)

+ MRM (181.0 -> 152.1) AV Z-Sep+ C5 spike 50ppb-1.D

Acquisition Time (m

22.2 22.3 22.4 22.5 22.6 22.7 22.8 22.9 23

Coun

ts 4x10

-0.2

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

2

2.2

2.4

2.6

2.8

3

3.2

3.4

3.6

3.8

4 22.641 min.

Ratio = 116.9 (337.0 %)

+ MRM (181.0 -> 152.1) AV Fatty dSPE spike 50ppb-1R.D

Acquisition Time (m

22.2 22.3 22.4 22.5 22.6 22.7 22.8 22.9 23

Coun

ts 4x10

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

2

2.1

2.2

2.3

22.645 min.

Ratio = 103.9 (299.5 %)

5994-0405EN

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201923

ULTRA Scientific is Now Part of Agilent Technologies

24

Agilent ULTRA Chemical Standards have:• Best in class online search, compare, and

ordering capabilities• Rapid shipping: 99.9% of orders dispatched within

24 to 48 hours• Custom solutions• Sample preparation materials, columns, supplies,

instrumentation, and reference materials from a single source

• Rigorously tested and manufactured under ISO 9001, ISO 17025, and Guide 34 certifications

You can calibrate with confidence and maximize accuracy

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

An Overview of the Latest Supply Innovations

Gas traps

Crimpers

SeptaLinersGold sealsColumn nuts

A-line vials

Latest columnsFID jets

Sample cleanup

ADM FlowmeterStandards

25 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

InletSepta

Liner

Gold seal

Column ferrule and nut

• Injection efficiency:– Main function of the inlet is to produce a narrow

sample band at the head of the column– One of the most important aspects to any high-

resolution GC method• Must be reproducible• The liner volume must be large enough to

accommodate the solvent’s phase transformation into a vapor (backflash)

• Most chromatography problems are “front-end” related

• Many consumables to replace: septa, liner, gold seal

• Inlet body must be cleaned/solvent rinsed periodically (no steel brushes, please)

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201926

30+ Years of R&D Focused on Surface Deactivation

UltiMetal Plus

• Inorganic vapor deposition in Middelburg

• CFT device

• Ultimate union

• Flexible metal ferrule

• Inlet welding

• Detector parts

• GC tubing

Ultra Inert

• Organic vapor deposition– Ultra Inert inlet liners– Ultra Inert gold seals

• Unique proprietary deactivation process

– UI columns

27

Two unique chemistries were developed to treat the surfaces in a GC flow path.

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Agilent Inert Flow Solution

Agilent UltiMetal Plus– TCD, FPD, NPD/FID jets

Agilent UltiMetal Plus capillary flow technologydevices, Ultimate union

Agilent J&W Ultra Inert GC column

Agilent Ultra Inert gold seal

Agilent Ultra Inert inlet liner

Agilent UltiMetal Plus ferrules

Agilent UltiMetal Plus inlet weldment, shell and transfer lines

5990-8532EN brochure

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201928

Septa• Typical cost of one premium septum (list), $1.25

• Typical cost of one GC column, 30 m x 0.25 mm id, $450

• Proactively change inlet septa

• Agilent packing eliminates contamination of septa

• “CenterGuide septa” puts less train on syringe compared to solid septa

• Do not overtighten septum nut; septum can begin to “bulge” out

• Should tighten nut until c-clamp on top stops turning, then ½ to ¾ turn more

Removed during PM

29 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Septum nut

Ultra Inert Inlet Liners

1. Ultra Inert deactivated inlet liners provide higher response for sensitive compounds

2. Ultra Inert glass wool liners deliver benefits of glass wool without loss of active compounds

3. QC tested and certified for consistent performance

ProductivityTouchless packaging with pre-installed O-ring: quick and easy hassle free installation

0

5

10

15

20

25

30

0 10 20 30 40 50 60 70 80 90 100

% E

ndrin

Bre

akdo

wn

Injection #

Restek Sky Liners (n=4) UI Liners (n=4)Competitor liners UI liners

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201930

Agilent Assurance

UI liner lot QC with demanding test probes (dinitrophenol and others)Assurance of consistent performanceLabel for p/n, batch, and lot testingTraceabilityDeactivation lot number is on certificate

• Liner lot number (and part number) etched on glass

November 12, 2019 Latest GC Supply Innovations Agilent Restricted31

Packaging, Ease, and Productivity

Individual liner

25/pk in Touchless dispenserHigh throughput

Convenient 5/pk in Touchless packaging

100/pk, bulk, blister(no O-ring)High throughput

32 Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

What’s New? Glass Wool Alternative LinersUltra Inert liners with sintered glass frits

Low frit single taper

liner

• Designed for dedicated splitless analyses

• Ideal for SVOCs and OC/OP pesticides

Mid frit single

taper liner

• General purpose split/splitless liner

• Ideal for basic drugs analysis

Porous glass frit

33 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

Modern Day Solution: The Glass-Frit

34

Substituting glass wool for a sintered glass frit provides equivalent vaporization properties while enhancing performance consistency and quality

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

PesticidesOrganochlorine pesticidesEndrin and DDT

Acids

Semivolatiles

PhenolsAcid-base pairsBenzidine

Dislodged glass wool fibers expose active sites that interact with sensitive analytesThe Benefits of the Glass Frit

Interaction with active sites results in

Tailing

Degradation

Carryover

Response loss

35 Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

Low frit liner gives excellent response and peak shape for tricky analytes like phenols8270 Chromatogram Overlay – Phenols/Low Frit Liner

min9 9.2 9.4 9.6 9.8 10 10.2 10.4 10.6 10.8

pA

0

20

40

60

80

100

120

Blue = Initial injection Red = After 100 matrix injectionsGreen = After liner replacement

Acenaphthene-d10

2,4-dinitrophenol

4-nitrophenol4,6-dinitro-2-methylphenol

5 ppm, 1 µL splitless injection FID detector

36 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

min6 8 10 12 14

150 pA

0

50

100

150

200

250

300

350

FPD1 A, Front Signal (Shear\FPD_2293_10-50 2018-05-15 20-02-44\50ppb_2293_v2_F2.D)

5.20

1

5.40

8 5.

556

6.16

2

6.34

4

6.75

7

7.06

5

8.39

2 8

.450

8.82

0

11.77

1

12.46

3

13.02

0

13.45

9

13.64

1

14.90

1

FPD1 A, Front Signal (Shear\FPD_P1_10-50 2018-05-18 08-54-29\50ppb_P1_v1_F2.D)

5.18

6

5.40

7 5.

556

6.16

2

6.34

2

6.75

6

7.06

4

8.39

0 8.

448

8.81

7

9.80

8

11.7

67

12.45

9

13.0

16

13.4

53

13.63

7

14.8

96

FPD1 A, Front Signal (Shear\FPD_P2_10-50 2018-05-22 10-19-20\50ppb_P2_v1_F2.D)

5.17

9

5.40

5 5.

555 6.

160

6.34

1

6.75

5

7.06

3

8.38

8 8.

446

8.81

5

11.76

4

12.45

8

13.01

2

13.44

8

13.63

2

14.8

92

FPD1 A, Front Signal (Shear\FPD_P3_10-50 2018-05-23 09-18-08\50ppb_P3_v1_F2.D)

5.17

3

5.40

6 5.

555

6.16

0

6.34

1

6.75

4

7.06

3

8.38

9 8.

447

8.81

5

9.80

9

11.76

4

12.45

6

13.01

1

13.44

8

13.63

2

14.8

93

FPD1 A, Front Signal (Shear\FPD_P4_10-50 2018-05-17 10-35-43\50ppb_P4_v1_F2.D)

5.17

9

5.40

8 5.

556

6.16

1

6.34

2

6.75

6

7.06

5

8.39

1 8.

448

8.81

9

11.7

68

12.46

0

13.0

17

13.45

1

13.63

8

14.89

7

FPD1 A, Front Signal (Shear\FPD_P5_10-50 2018-05-21 09-51-39\50ppb_P5_v1_F2.D)

5.19

4

5.40

5 5.

554

6.15

9

6.34

1

6.75

3

7.06

1

8.38

7 8.

445

8.81

4

9.80

4

11.76

4

12.45

6

13.01

2

13.44

8

13.63

3

14.8

92

Results for fritted liner indicate highly inert, consistent responsePesticides by FPD

min8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9

150 pA

0

50

100

150

200

250

300

FPD1 A, Front Signal (Shear\FPD_2293_10-50 2018-05-15 20-02-44\50ppb_2293_v2_F2.D)

8.39

2

8.45

0

8.82

0

FPD1 A, Front Signal (Shear\FPD_P1_10-50 2018-05-18 08-54-29\50ppb_P1_v1_F2.D)

8.39

0

8.44

8

8.81

7

FPD1 A, Front Signal (Shear\FPD_P2_10-50 2018-05-22 10-19-20\50ppb_P2_v1_F2.D)

8.38

8

8.44

6

8.81

5

FPD1 A, Front Signal (Shear\FPD_P3_10-50 2018-05-23 09-18-08\50ppb_P3_v1_F2.D)

8.38

9

8.44

7

8.81

5

FPD1 A, Front Signal (Shear\FPD_P4_10-50 2018-05-17 10-35-43\50ppb_P4_v1_F2.D)

8.39

1

8.44

8

8.81

9

FPD1 A, Front Signal (Shear\FPD_P5_10-50 2018-05-21 09-51-39\50ppb_P5_v1_F2.D)

8.38

7

8.44

5

8.81

4

Chlorpyrifos methyl

Fenitrothion

37 Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

Agilent UI Gold Seal: Deactivated Gold Surface

• Soft gold plating is essential for proper sealing • Ultra Inert chemistry blocks active sites (gold is notinert)• Smooth surface doesn't leak (injection molded)• Part numbers 5190-6144 ea. 5190-6145, 10/pk. 5190-6149, 50/pk.

Agilent MIM seal Competitor’s machined seal

Reliable ppb and ppt measurements require attention to the little things

November 12, 201938 Latest GC Supply Innovations Agilent Restricted

For mass spectrometry transfer lineNovember 12, 2019

39

• Spring driven piston continuously presses against ferrule

• Automatically retightens when ferrule shrinks

• No leaks, no downtime, no frustration

• Wing design for finger tightening

• No tools needed

• No polymer materials for durability

• Compatible with only short graphite • Vespel ferrules

For inlet or detector

Column Installation: Self-Tightening Column Nut

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

40

Increasing Ease of Use Through Continued Innovation: Self-Tightening Nuts

For mass spectrometry transfer line

For GC inlet or detector

Innovating for the next generation

Innovating for the next generation

• Easier and faster to install

• Collar holds column in place

• Single-hand installation into inlet

• No tools needed

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

• Spring-driven piston continuously presses against ferrule

• Automatically retightens when ferrule shrinks

• Wing design for finger tightening

• No tools needed

November 12, 201941

Self-Tightening Nuts: No leaks, No Downtime, No Frustration

400 injections

Part Number DescriptionG3440-81013 Column Nut, Collared Self-Tightening MSDG3440-81011 Column nut, Collared Self Tightening Inlet/DetectG3440-81012 Collar for Self Tigthening Nut

Latest GC Supply Innovations Agilent Restricted

An Overview of the Latest Supply Innovations

Gas traps

Crimpers

SeptaLinersGold sealsColumn nuts

A-line vials

Latest columnsFID jets

Sample cleanup

ADM FlowmeterStandards

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201942

Low Polarity Mid Polarity High PolarityCP-Sil 2 DB & HP-1MS UI DB & HP-5MS UI DB-XLB DB-225MS DB-ALC1 HP-88 DB-WAX DB-WAX UI

DB-MTBE DB & HP1-MS DB & HP5-MS VF-XMS DB-225 DB-Dioxin CP-Sil 88 DB-WAX ETR DB-HeavyWAX

CP-Select CB MTBE VF-1MS VF-5MS DB-35MS UI CP-Sil 43 CB DB-200 DB-23 HP-INNOWax DB-FATWAX UI

DB & HP-1 DB & HP-5 DB & VF-35MS VF-1701 MS VF-200MS VF-23 MS VF-WAX MS

CP-Sil 5 CB CP-Sil 8 CB DB & HP-35 DB-1701 DB-210 CP-WAX 57 CB

Ultra 1 Ultra 2 DB & VF-17MS CP-Sil 19 CB DX-4 DB & HP-FFAP

DB-1HT VF-DA DB-17 HP-Blood Alcohol DB-WAX FF

DB-2887 DB-5.625 HP-50+ DB-ALC2 CP-FFAP CB

DB-Petro/PONA DB & VF-5HT DB-17HT DX-1 CP-WAX 58 FFAP CB

CP-Sil PONA CB CP-Sil PAH CB DB-608 CP-WAX 52 CB

DB-HT SimDis Select Biodiesel DB-TPH CP-WAX 51

CP-SimDis SE-54 DB-502.2 CP-Carbowax 400

CP-Volamine HP-VOC Carbowax 20M

Select Mineral Oil DB-VRX HP-20M

HP-101 DB-624 CAM

SE-30 VF-624MS CP-TCEP

CP-Select 624 CB

DB-1301

VF-1301MS

CP-Sil 13 CB

Agilent J&W columns have over 50 different stationary phase

offerings

Agilent J&W Column Portfolio- DB, HP, CP, VF

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201943

Introducing DB-HeavyWAX

• WAX column with increased MAOT compared to existing columns on the market– 280 °C isothermal and 290 °C programmed

• Provides increased thermal stability• Has a low bleed level

General GC

• Shorter runtimes when late eluters are present

• Better S/N ratio, improved detection

• Better thermal stability• Faster column bake-out

GC/MS

• Desire for “zero” bleed• Avoid MS contamination by

column bleed for longer system uptime and column lifetime

• Improve detection limit

GC×GC

• Extended scope of compounds

November 12, 201944 Latest GC Supply Innovations Agilent Restricted

Advantages

Response Units (%) vs. Acquisition Time (min)1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 310

20

40

60

80

10

30

50

70

90

pA

DB-HeavyWAX at 100 hours

DB-HeavyWAX at 0 hours

WAX A at 0 hours

WAX B at 0 hours

WAX A at 100 hours

WAX B at 100 hours

Bleed Summary at 280 °C Over 100 Hours

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201945

Thermal Stability and Retention Time Shifting for a Traditional WAX Phase

Peak Compound1 Methanol2 Benzene3 Toluene4 Ethylbenzene5 p-Xylene6 m-Xylene7 o-Xylene

Application note 5991-9035EN

2.4 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 7 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 8 8.1 8.2 8.3 8.4

Initial BTEX injection

25 h at 280 °C

50 h at 280 °C

1

2

3

4 5 6

7

1 min earlier

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201946

2.8 2.9 3 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 4 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 5 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 7 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 8 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8

Initial Injection

25 h at 280 °C

50 h at 280 °C

75 h at 280 °C

100 h at 280 °C1

2

3

4 5 67

Application note 5991-9035ENDB-HeavyWAXPeak Compound

1 Methanol2 Benzene3 Toluene4 Ethylbenzene5 p-Xylene6 m-Xylene7 o-Xylene

Only a few seconds of

shift

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201947

Higher Final Temperatures Mean Earlier Elution of Heavy Compounds, Sharper Late Eluting Peaks, and Reduced CarryoverPink grapefruit essential oil (cold pressed)

2x10

-0.1-0.05

00.050.1

0.150.2

0.250.3

0.350.4

0.450.5

0.550.6

0.650.7

0.750.8

0.850.9

0.951

1.05 Final temp 250 °C1

2x10

-0.1-0.05

00.050.1

0.150.2

0.250.3

0.350.4

0.450.5

0.550.6

0.650.7

0.750.8

0.850.9

0.951

1.05 Final temp 280 °C1

Counts (%) vs. Acquisition Time (min)3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69

Initial Injection

Repeat Injection

Meranzin

Isomeranzin

Osthole

Carryover compounds

Application note 5991-9078ENLatest GC Supply Innovations Agilent RestrictedNovember 12, 201948

Better Peak Shape and Decreased Runtime

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5

DB-HeavyWAXRun time: 13 minFinal temp: 280 °C Ramp: 30 °C/min Flow: 5 mL/min

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

1.3

1.4

1.5 DB-WaxRun time: 19 minFinal temp: 250 °C Ramp: 30 °C/min Flow: 5 mL/min

Response Units (%) vs. Acquisition Time (min)0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17 17.5 18 18.5 19 19.5 20

C9

C10

C18C16C14

C12

C20 C22 C24

C26

C28

C30C32

C34C36

C9

C10

C18C16C14

C12C20 C22

C24 C26 C28

C30

C32

C34C36

Final temp reached

Final temp reached

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201949

2x10

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2Agilent J&W DB-HeavyWAX

2x10

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

1.1

1.2

Competitor A

Counts (%) vs. Acquisition Time (min)27.5 28 28.5 29 29.5 30 30.5 31 31.5 32 32.5 33 33.5 34 34.5 35 35.5 36 36.5 37 37.5 38 38.5 39 39.5 40 40.5 41 41.5 42 42.5 43 43.5 44 44.5 45 45.5 46 46.5 47 47.5 48 48.5 49 49.5 50 50.5 51 51.5 52 52.5 53

Bleed 8.8 pA

Bleed 3.1 pA12

3

4 5 76

12

3

45

76

Bleed Reductions for FAMEs in Biodiesel (IP-585) Using a DB-HeavyWAX, 60 m x 0.25 mm x 0.50 µm

Peak FAME1 C16:02 C17:0-d33 (IS)3 C17:04 C18:05 C18:16 C18:27 C18:3

November 12, 201950 Latest GC Supply Innovations Agilent Restricted

• Great need in the food, forensic, and cosmetic industries to monitor the content of free and natural occurring fatty acids.

• Analysis of underivatized organic acids and free acids is desirable to eliminate the problems associated with derivatization, extraction, and cleanup procedures

• Volatile organic acids and fatty acids are difficult to quantify accurately by standard WAX columns. These acids often elute as tailing or poorly resolved peaks. For some acids, adsorption can become irreversible.

• Normally:– Fatty acids are derivatized to the methyl ester (FAME)– Free fatty acids are analyzed using acid-deactivated WAX columns. The acid modifier,

nitroterephthalic acid, however, reduces thermal stability, operating temperature and reacts with humidity, reducing column life.

DB-FATWAX UI Provides the Desired Inertness and Thermal Stability to Separate Challenging Organic Acids and Fatty Acids

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201951

min5 10 15 20 25

pA

10

20

30

40

50

60

min5 10 15 20 25

pA

10

20

30

40

50

60

Compound Identification1. 2-Nonanone2 Decanal3. Propionic Acid4. Ethylene Glycol5. Heptadecane6. Aniline

7. Methyl Dodecanoate8. 2-Chlorophenol9. 1-Undecanol10. Nonadecane11. 2-Ethylhexanoic Acid12. Ethyl Maltol

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

12

1211

Standard acid-modified WAX

DB-FATWAX Ultra Inert

Comparison Between Acid-Modified WAX and DB-FATWAX UI After 50 h at 250 ºCDB-FATWAX Ultra Inert shows superior inertness and thermal stability compared to acid-modified WAX

52 November 12, 2019 Latest GC Supply Innovations Agilent Restricted

November 12, 2019

DB-FastFAME20 m x 0.18 mm x 0.20 μm

min1 2 3 4 5 6 7

C21:

0C2

0:3n

6C2

0:4n

6C2

0:3n

3

C20:

5n3

(EPA

)C2

2:0

C22:

1

C24:

0

C22:

2C2

3:0

C24:

1C2

2:6

(DHA

)C4:0

C6:0

C8:0 C1

0:0

C11:

0

C12:

0

C13:

0

C14:

0C1

4:1

C15:

0C1

5:1

C16

:0

C17:

0

C17:

1

C16:

1 C18:

0 C18:

1tra

ns

C18:

2 tra

ns

C18:

1 ci

s

C18:

2 ci

s C1

8:3

n 6

C18:

3 n

3

C20:

0C2

0:1n

9

C20:

2

C18

:1tr

ans

C18

:2 tr

ans

C18

:2 c

is

C18:1 cis

C20

:5n3

(EPA

)C

22:0

C24

:0

C24

:1C

22:6

(DHA

)

C20

:4n6

C20

:3n3

C21

:0C

20:3

n6

RS ≥ 1.95 for cis/trans isomers

RS = 1.51RS = 1.56

C21:0, C20:3n6, C20:4n6RS ≥ 1.52

Column Agilent J&W DB-FastFAME, 20 m x 0.18 mm, 0.20 µm Gas Hydrogen, 28 psi, constant pressure mode Inlet Split/splitless, 250 °C, split ratio 50:1 Oven 80 °C (0.5 min), 65 °C/min to 175 °C, 10 °C/min to 185 °C (0.5 min),

7 °C/min to 230 °C

FID 280 °C, hydrogen: 40 mL/min; air: 400 mL/min; make-up gas: 25 mL/min.

Injection 1 µL

TransCis

Strong interaction between cis isomers and the dipoles of the cyano propyl ligands. That allows the trans to elute after the cis isomers.

7 min analysis time

53 Latest GC Supply Innovations Agilent Restricted

54

Introducing the Agilent 8890 GC SystemFlexible and expandable to meet your needs today and tomorrow

Future-proof: Ready for anything — Powerful next generation electronic

architecture— Expanded smart-connected functionality— Full suite of inlets, detectors, and accessories,

CFT, Deans switch, backflush, GC x GC, dual simultaneous injection

— Six valves, eight heated zones, plus LVO— Generation 6 precision EPC— Smart keys— 7-inch color touch display

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

55

Agilent 8890 GC SystemSmart-connected GC

Modern intuitive interface— 7-inch color touch screen

— Configuration— Status— Methods— Sequence info— Troubleshooting, diagnostics, and help

— Real-time chromatographic evaluation— Blank evaluation— Detector evaluation

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

• Available with the Agilent 8890 GC only

• Can track use of a GC column

• Smart key contains GC column information, including:– Part and serial numbers– Number of injections/runs– Time at/above temperature limits– Date installed– Temperature limits – GC columns

• If more than one column is installed, the temperature is determined by lowest column smart key installed (DB-WAX vs DB-5)

– Column length/trimming done in “column maintenance mode” in software and rewritten to the smart key

– S/N of last instrument installed if it was in an 8890 GC

56

For immediate identification and usage monitoring of your GC columnGC Columns with Smart Key (for the Agilent 8890 GC only)

Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

57

Feature Advantage Benefit Economic BenefitSmart key included with the GC column p/n must include “KEY” Designation example*122-5532UI-KEY*

1. Reduce possible errors of manual input of method parameters

2. Optimized maintenance schedules with usage tracking

1. Better data quality as the system is aware of the configurationEase-of use

2. Ability to better plan preventive maintenance before issues occur

1. Ease-of-use, no risk of faulty information in GC, fewer reruns

2. Limited downtime as preventive maintenance is easier to plan

GC Columns with Smart Key

Feature, advantages, and benefits

Literature Web page

1 Agilent 8890 GC brochure https://www.agilent.com/cs/library/brochures/brochure-gc-8890-5994-0476en-agilent.pdf

2 Smart key product page (not for ordering smart keys)

www.Agilent.com/chem/smartkey8890

3 Instruction sheet https://www.agilent.com/cs/library/instructionsheet/public/insert-smart%20key-8890-5994-0700en-agilent.pdf

November 12, 2019 Latest GC Supply Innovations Agilent Restricted

• It is not a USB flash drive. It comes already programmed from the factory with specific information about the GC column that it belongs to

• It is not tethered to the GC column, neither is connected through it with WIFI or Bluetooth.

58

Smart key clarificationsGC Columns with Smart Key

Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019

November 12, 201959

Expanding the Intuvo Column FamilyKey features• VF-, CP-, and Select- applications specific: 24 new phases and 39 new part numbers

• New Intuvo column dimension: 0.15 mm id to add to our 0.18 mm id for a greater range

of high-efficiency columns

• We now have PLOT columns

• Custom column options

VF-1ms VF-5ms CP-WAX 52 CB

CP-Volamine VF-17ms HP-PLOT Q

CP-Sil 5 CB CP-Sil 8 CB VF-WAXms Select Mineral Oil

VF-1701ms HP-PLOT Al2O3 S

CP-Sil 8 CB for Amines

CP-WAX 57 CB

Select PAH VF-Xms

CP-WAX 58 FFAP

Select Low Sulfur

VF-624ms

CP-Wax for Volamine

Select-FAME CP-Select 624 CB

CP-Sil 88 for FAME

CP-Sil 88

CP-TAP VF-200ms

PDMS 5% Phenyl WAX SpecialtySiloxane/ Cyanopropyl PLOT

Latest GC Supply Innovations Agilent Restricted

An Overview of the Latest Supply Innovations

Gas traps

Crimpers

SeptaLinersGold sealsColumn nuts

A-line vials

Latest columnsFID jets

Sample cleanup

ADM FlowmeterStandards

Latest GC Supply Innovations Agilent RestrictedNovember 12, 201960

New Agilent Universal Fit GC Detector Jets

• Easier column installation and jet replacement reducing the risk of column damage

• Lubricant free threads reducing the risk of contamination

• Made of strong material reducing the risk of deforming

• Universally fits in both capillary column and packed column (adaptable) FID detectors

November 12, 201961 Latest GC Supply Innovations Agilent Restricted

Upcoming GC Seminars

Have an idea for a topic? Let us know.

November 12, 201962

How to combat the Helium Shortage: Making the Switch from Helium to Hydrogen or Nitrogen Carrier Gas

December 5, 2019 11:00am ET/8:00am PT

Optimizing Conditions for GC/MS Analyses

January 23, 2020 11:00am ET/8:00am PT

Plunge Deep into the World of Syringes: Simplifying GC Syringes and Sample Introduction

February 27, 2020 11:00am ET/8:00am PT

An Agilent Guide to SPME Analysis

March 26, 2020 11:00am ET/8:00am PT

Latest GC Supply Innovations Agilent Restricted

Contact Agilent Chemistries and Supplies Technical Support

1-800-227-9770 option 3, option 3:Option 1 for GC and GC/MS columns and suppliesOption 2 for LC and LC/MS columns and suppliesOption 3 for sample preparation, filtration, and QuEChERSOption 4 for spectroscopy suppliesOption 5 for chemical standardsAvailable in the USA and Canada 8–5, all time zones

[email protected]@[email protected]@[email protected]

63 Latest GC Supply Innovations Agilent RestrictedNovember 12, 2019