Page 1: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

A Guide to Safe Use of the

Wheelchair Lift Located in the Lowndes Hall Auditorium,

Room 7175A, at Wiregrass Georgia

Technical College.

Page 2: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The wheelchair lift is located in the Lowndes Hall auditorium, room 7175A. It is used to elevate persons in wheelchairs to stage level providing them access to the stage.

Page 3: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The auditorium is located off of the lobby on the 1st floor, west end of Lowndes Hall.

Page 4: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The wheelchair lift is located to the right of the stage. It is a Garaventa GSL ARTIRA inclined platform lift.

Page 5: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The wheelchair lift is an all electric unit which allows wheelchair users unassisted use and access to the stage level. Keys to operate this lift are issued by the Security Dept. at ext. 3175 or Facilities dept. at ext. 5118 or ext. 3075

Page 6: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The main power switch for the wheelchair lift is located on the wall to the left of the lift. It is normally left in the “ON” position.

Page 7: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step One:

Make sure that the main power switch is in the “ON” position.

Page 8: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Two:

Make sure that the equipment breaker is in the “ON” position. It is located at the top of the track rail. The lift will not operate with equipment breaker in the “OFF” position. It is normally left in the “ON” position.

Page 9: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Three:

Locate the lift controls located on the wall to the right of the lift. Be sure to read the

operating instructions and the lift capacity information located above these controls.

Page 10: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Four:

Insert the key and turn it to the “ON” position. The up down arrow buttons will illuminate green. If these do not illuminate, then check to insure that the main power switch, the equipment breaker, and the Emergency Stop switch are all in the “ON” position. The Emergency Stop switch is located near the controls on the lift and is used by the user to kill power in emergency situations. Should any of these three switches be in the “OFF” position, the lift will not operate.

Page 11: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

In an emergency, the user should push in on the Emergency Stop button(red button) located just above the green lift buttons. The lift will not operate until the Emergency Stop button is reset. To reset the Emergency Stop button, pull out until it clicks.

Page 12: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

During the lift chair operation, the strobe located on the wall above the lift will flash and alarms will chime. This is to warn occupants in close proximity of possible danger during lift use. The lift is equipped with many safety switches around and under the lift platform that will automatically stop the lift when pressure exceeds a few pounds.

Page 13: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Five:

Push the down arrow button to lower the lift platform.

Page 14: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

The lift platform should lower fully and be flush with the floor.

Page 15: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Six:

Remove the key from the wall controls and roll the wheelchair onto the lift platform. The wheelchair wheels should be locked at this time to prevent the chair from rolling during operation.

Page 16: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Seven:

Insert the lift key in to the on-board control panel and turn to the “ON” position. At this time, the safety bars will lower around the user to prevent them from falling from the lift.

Page 17: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

On-board up arrow button to raise the lift.

Page 18: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Eight:

Use the on-board up arrow button to raise the platform to the stage level.

Page 19: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Nine:

Once the lift is fully at stage level, the exit ramp will drop in place and the safety arms will raise out of the operators way to allow exit. The user should turn the key to “OFF” position, remove it from the on-board panel, unlock their wheels and exit the lift.

Page 20: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Ten:

When the user is ready to leave the stage, they should enter the lift, lock their wheels, insert the key and turn the key to ”ON”.

Page 21: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Eleven:

Push the down arrow button to lower the lift. At this time, the safety bars will automatically lower around the user.

Page 22: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Twelve:

When the lift is fully down, the safety arms will raise and the user should unlock their wheels, remove the key, and exit the lift.

Page 23: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Thirteen:

Insert the key on the wall controls located on the right side to the lift and turn the key to the “ON” position.

Page 24: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Fourteen:

Push the green arrow up button to raise the lift to the stored position.

Page 25: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Raise the lift fully to the stored position so it is ready for future use.

Page 26: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Fifteen:

When the lift is fully raised, turn the key to “OFF” and remove it from the control panel.

Page 27: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

Step Eighteen:

Return the lift keys to the department they were borrowed.

Page 28: A Guide to Safe Use of the Wheelchair Lift Located in the Lowndes Hall Auditorium, Room 7175A, at Wiregrass Georgia Technical College.

If you need assistance with the wheelchair lift, please contact the Security Department at ext. 3175 or the Facilities Department at ext. 5118 or ext. 3075