DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
CATALOG NUMBER ADAPTER TYPE # OF TERMINATIONSMX6-TMBLR00 ASC 96
MX6-TMB2R00 FC 96
MX6-TMB7R00 SC 96
MX6-TMBVR00 E-2000ANGLED 8
96
MX6-TMALR00 ASC 72
MX6-TMA3R00 FC (ZIRCONIA) 72
MX6-TMA7R00 SC 72
MX6-TMA2R00 FC 72
MX6-TMB9R00 MMSC 96
MX6-TMAQR00 AFC 8° 72
MX6-TMCXR00 LX.5 144
MX6-TMB001 SMSC/MMSC 1-48/49-96
MX6-TMB3R00 FC (ZIRCONIA) 96
MX6-TMCPR00 LC 144
MX6-TMA5R00 ST 72
MX6-TMBAR00 MMFC 96
1 MX6-TMALR00-TF ASC 72
MX6-TMA9R00 AFC 8° 96
MX6-TMA9R00 MMSC 72
MX6-TMCKR00 LC DUPLEX 144
MX6-TMA4R00 ST 72
MX6-TMA9R00-H MMSC 72
MX6-TMAVR00-H AE-2000 72
MX6-TMB9R00-H MMSC 96
MX6-TMCMR00 ALC 144MX6-TMCSR00 LC/APC 144MX6-TMB4R00 SMST 96MX6-TMAVR00 AE-2000 72
MX6-TMA7R00-H SC 72MX6B-TMCXR00 ALX.5 144MX6-TMCKR00-H LC DUPLEX 144MX6-TMCPR00-H MMLC DUPLEX 144MX6-TMALR00-H ASC 72
MX6-TMCQ2R00-H MMLC AQUA 144MX6B-TMCKR00 LC DUPLEX 144
MX6B-TMCMR00-H ALC 144MX6B-TMCQ2R00-H MMLC AQUA 144
144
RECOMMENDED CONNECTION TABLEFOR 96 POSITIONS
TERMINATION MODULES
UPPER POSITIONS
1 7 13 19 25 31 37 43
2 8 14 20 26 32 38 44
3 9 15 21 27 33 39 45
4 10 16 22 28 34 40 46
5 11 17 23 29 35 41 47
6 12 18 24 30 36 42 48
LOWER POSITIONS
49 55 61 67 73 79 85 94
50 56 62 68 74 80 86 92
51 57 63 69 75 81 87 93
52 58 64 70 76 82 88 94
53 59 65 71 77 83 89 95
54 60 66 72 78 84 90 96
RECOMMENDED CONNECTION TABLEFOR 72 POSITIONS
TERMINATION MODULES
UPPER POSITIONS
1 7 13 19 25 31
2 8 14 20 26 32
3 9 15 21 27 33
4 10 16 22 28 34
5 11 17 23 29 35
6 12 18 24 30 36
LOWER POSITIONS
37 43 49 55 61 67
38 44 50 56 62 68
39 45 51 57 63 69
40 46 52 58 64 70
41 47 53 59 65 71
42 48 54 60 66 72
NOTES: 1 USE SPECIAL LABEL. 2 USE TABLE ON PAGE #2 FOR MODULES WITH HORIZONTAL SEQUENCE CONNECTION.
96 POSITION(SHOWN FOR REFERENCE)
72 POSITION(SHOWN FOR REFERENCE)
MX6B-TMCMR00 ALC
DATEDWNMCOREVAU
03-OCT-14LLBV40017128MCOAT
14-OCT-14LLBV40017384MCOAU
SHT. OFDWN: CHRISTINE CULVER
DO NOT SCALE DRAWING ENGR: CHARLES CAZETT
AUREV1156217_ADC
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
OMX RIGHT TERM MODULEINSTALLATION DRAWING
TITLEINFORMATION ON THIS DOCUMENT ISPROPRIETARY TO TE CONNECTIVITY ANDSHALL NOT BE USED, COPIED, REPRODUCED ORDISCLOSED IN WHOLE OR IN PART WITHOUTWRITTEN CONSENT OF TE CONNECTIVITY.
STRANDED FIBER(FIBER SHOWN FOR REFERENCE)
DRAWING NUMBER
4
3
2
11
2
3
4
DCBA
CBA
2 2
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
RECOMMENDED CONNECTION TABLE FOR 96 POSITIONS HORIZONTAL SEQUENCE 2
TERMINATION MODULES
UPPER POSITION
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48
LOWER POSITION
49 50 51 52 53 54 55 56
57 58 59 60 61 62 63 64
65 66 67 68 69 70 71 72
73 74 75 76 77 78 79 80
81 82 83 84 85 86 87 88
89 90 91 92 93 94 95 96
RECOMMENDED CONNECTION TABLE FOR 72 POSITIONS HORIZONTAL
SEQUENCE2
TERMINATION MODULES
UPPER POSITION
1 2 3 4 5 6
7 8 9 10 11
12
13 14 15 16 17 18
19 20 21 22 23 24
25 26 27 28 29 30
31 32 33 34 35 36
LOWER POSITIONS
37 38 39 40 41 42
43 44 45 46 47 48
49 50 51 52 53 54
55 56 57 58 59 60
61 62 63 64 65 66
67 68 69 70 71 72
RECOMMENDED CONNECTION TABLE FOR 144 POSITIONS HORIZONTAL SEQUENCE
2
CONNECTION TABLE
ROWUPPER POSITION FIBER BUNDLE NUMBER
1 2 3 4 5 6
POSITION/ COLOR
1 1 2 3 4 5 6 7 8 9 10 11 12
2 13 14 15 16 17 18 19 20 21 22 23 24
3 25 26 27 28 29 30 31 32 33 34 35 36
4 37 38 39 40 41 42 43 44 45 46 47 48
5 49 50 51 52 53 54 55 56 57 58 59 60
6 61 62 63 64 65 66 67 68 69 70 71 72
ROW
LOWER POSITION/FIBER BUNDLE NUMBER
7 8 9 10 11 12
POSITION/ COLOR
7 73 74 75 76 77 78 79 80 81 82 83 84
8 85 86 87 88 89 90 91 92 93 94 95 96
9 97 98 99 100 101 102 103 104 105 106 107 108
10 109 110 111 112 113 114 115 116 117 118 119 120
11 121 122 123 124 125 126 127 128 129 130 131 132
12 133 134 135 136 137 138 139 140 141 142 143 144
SHT. OFDWN: CHRISTINE CULVER
DO NOT SCALE DRAWING ENGR: CHARLES CAZETT
AUREV1156217_ADC
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
OMX RIGHT TERM MODULEINSTALLATION DRAWING
TITLEINFORMATION ON THIS DOCUMENT ISPROPRIETARY TO TE CONNECTIVITY ANDSHALL NOT BE USED, COPIED, REPRODUCED ORDISCLOSED IN WHOLE OR IN PART WITHOUTWRITTEN CONSENT OF TE CONNECTIVITY.