9400 AWY Help Full

download 9400 AWY Help Full

of 177

Transcript of 9400 AWY Help Full

  • Alcatel 9400 AWY software & Alarms solutions

    Presented by Eng: Mohamed Tag EL DIN Fouad

    Supervised by Eng : Mohamed Reda Menallah Moussa

  • Agenda

    Alcatel 9400 AWY 1320 CT Setup

    Alcatel 9400 AWY Software

    Alarms Handling ware

    3.AWY 2.0.4 Alarms Handling

    2

  • 1320 CT Set up 6

    installation of 1320 CT package 20

    configuration menu 26

    Diagnosis 57

    supervision 76

    SW Download 88

    Equipment 94

    External point menu 103

    line interface 106

    performance 110

    Radio 122

    protection schemes 137

    loopback 155

    Alarms Handling 162

    3

    Appendix :-

  • 1320 CT REQUIRMENT

    This section describes the recommended minimum HW/SW requirements of the

    ECT application for a recognized level of application performances

    HW CONFIGURATION

    .CPU : Pentium III 850 MHz

    .RAM : 512 Mbytes mandatory

    .HARD DISK SPACE : 4 Gbyte

    .DISPLAY RESOLUTION : 1024 x 768 pixel

    .CD-ROM DRIVE : 24x

    .PRIMARY INTERFACE : serial port RS-232-c 9.6 to 57.6 Kbps

    .OPTIONAL INTERFACE : Ethernet card 10/100 Mbps

    4

  • Windows versions

    .Windows 2000 till sp4 included

    .Windows XP professional Edition (till sp2 included). It is mandatory to de-active the firewall

    installed

    Additional requirements

    .Netscape communicator or Ms Internet Explorer 4.x or higher

    .Java 2 Run time Environment versions from 1.4.2-12

    NOTE: Each specific Java version could require minimal Windows sp installation

    5

  • 1320 CT Setup

    Put REGAWY_204 INTO CD ROM

    IT WILL START AUTO RUN

    6

  • SELECT ADVANCED SETTING

    7

  • INSTALL JAVA JRE PACKET

    8

  • PRESS RUN

    THEN INSTALL SERIAL-F-INTERFACE DRIVER

    AT THE END FILL THE LOWER LAYER SETTING

    BY 000000000000 IN SYSTEM IDENTIFIER , SEREIAL PORT IN SUB-

    NETWORK TYPE ,

    COM NOMBER IN SERIAL PORT AND DEFAULT IN PORT SPEED

    NOTE: if pc haven't serial interface you must plug usb to serial converter during

    installation

    9

  • 10

  • After lower layer you must add alcatel lower layer network card

    From control panel add new hard ware then press next

    11

  • Select add new hardware

    12

  • Select network adapters

    13

  • Select have a disk then browse

    c:\windows\system32\driver\llmannic\oemsetup.inf

    14

  • 15

  • From network connection

    Select alcatel lower layer network card

    16

  • Put mark on internet protocol (tcp/ip) only

    17

  • Put ip address and subnet mask

    18

  • Disable firewall

    19

  • Complete installation by install 1320 ct package installation

    20

  • Alcatel 9400 AWY version 2.0.4 Software

    Before access on the microwave you should have the 9 pin cable RS 232 as

    shown to be plugged on the ECT in the microwave IDU

    21

  • Alcatel 9400 AWY version 2.0.4 Software

    Open the software, right click to start the supervision on the microwave as shown

    below

    22

  • Alcatel 9400 AWY version 2.0.4 Software

    After you started supervision, the lct gives you the name of the microwave link,

    then

    You begin to show equipment as shown below

    23

  • Alcatel 9400 AWY version 2.0.4 Software

    After you select show equipment , you will enter the application username and

    password which are 1-user name : initial as shown below

    2-password:initialing

    24

  • Now, we are going to display main tabs which are essential to understand our equipment :-

    1- configuration 2- Diagnosis 3-supervision 4-sw download

    Alcatel 9400 AWY version 2.0.4 Software

    25

  • Alcatel 9400 AWY version 2.0.4 Software

    1)configuration: -

    this tab includes the following:-

    1.1-NE Time 1.2-Network configuration 1.3-Alarm Severities

    1.4-system settings 1.5-Quick Configuration 1.6-Profile management

    26

  • Alcatel 9400 AWY version 2.0.4 Software

    1.1)NE Time:-

    The NE Time box displays the current NE time and OS time as shown below.

    27

  • 1.2)Network Configuration: this configuration allows to perform the following

    operations as:- 1.2.1)local configuration 1.2.2)NTP configuration

    1.2.3)Ethernet configuration 1.2.4) IP configuration

    1.2.5)Quick Configuration

    Alcatel 9400 AWY version 2.0.4 Software

    28

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.1)Local configuration:-

    IT defines the local NE IP address as shown below

    29

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.2)NTP Configuration:-

    This Configuration allows to enable/disable the network time protocol as shown

    below.

    30

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.3)Ethernet Configuration:-

    this configuration allows to define the parameters necessary for the Ethernet

    interface as shown below.

    31

  • 1.2.4 )IP configuration:

    This menu is divided in three submenus.

    1.2.4.1) IP static routing configuration 1.2.4.2 )OSPF area configuration

    1.2.4.3 )IP Point to Point configuration

    Alcatel 9400 AWY version 2.0.4 Software

    32

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.4.1) IP static routing configuration:-

    This menu defines the host destination address for IP static routing configuration

    for the NMS Channels Used

    33

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.4.2) OSPF Area Configuration: -

    This menu defines the open shortest path first address which gives a synthetical

    information that includes all the addresses specific to NE in an Area (NMS

    ,Ethernet) features

    34

  • Alcatel 9400 AWY version 2.0.4 Software

    1.2.4.3) IP Point to Point Configuration :-

    This menu allows to Enable or Disable the three NMS Channel which use the

    ppp protocol .

    35

  • Alcatel 9400 AWY version 2.0.4 Software

    36

  • Alcatel 9400 AWY version 2.0.4 Software

    1.3) Alarm Severities:-

    the alarm severities is divided into four profiles:-

    1-NO Alarms: within this profiles all alarms are disabled

    2-Primary alarms : This profile enable the emission of the primary alarms

    within the Major, Minor and warning alarm severity

    3-NO Remote Alarms

    4-All Alarms: This profile enables the emission of all the alarms on the

    microwave

    37

  • Alcatel 9400 AWY version 2.0.4 Software

    38

  • Alcatel 9400 AWY version 2.0.4 Software

    1.4) System Settings:-

    This Menu allows the system configuration , providing the setting of all

    parameters for the NE setup.

    39

  • Alcatel 9400 AWY version 2.0.4 Software

    1.4 )System Settings:-

    40

  • Alcatel 9400 AWY version 2.0.4 Software

    1.5) Quick Configuration:- This is a very important menu that contains all

    configurations for this microwave link, this configuration will be saved on a flash

    memory stored at the back of the IDU ,This menu is used in case of

    commissioning the microwave with anew flash card (Data entry for the IDU),

    we have 2 types of Quick Configuration 1- by interactive mode

    2-by text file

    1- by interactive mode:-This procedure allows a full system configuration through

    a guided process. The related windows will be displayed by a wizard tool to

    enter the link configuration (manual configuration)

    2- by text mode:- This procedure allows the user to load a NE configuration from

    a structured XML file , the text file will ask the user to choose a configuration

    file through a file browser ,then the user select his own configuration

    (Automatic configuration).

    41

  • Alcatel 9400 AWY version 2.0.4 Software

    1.5.1) Quick Configuration by interactive mode steps:-

    1st step :- let us make configuration of non protected 1+0 link

    42

  • Alcatel 9400 AWY version 2.0.4 Software

    1st step in case of 1+1 HSB

    43

  • Alcatel 9400 AWY version 2.0.4 Software

    2nd step :- this wizard allows to choose the tributary configuration and the signal

    mode status should be selected to be unframed, in case you disabled

    it ,you will find no transmission alarms for the free ports in the NE , but you

    should select the unframed signal mode to use all ports

    44

  • Alcatel 9400 AWY version 2.0.4 Software

    3rd step in case of 1+0 non protected link :-This menu allows you to define the

    basic parameters for each configured channel as TX power(transmitted power),

    TX , RX frequencies and the shifter

    .

    45

  • Alcatel 9400 AWY version 2.0.4 Software

    3rd step in case of 1+1 HSB protected link:-

    46

  • Alcatel 9400 AWY version 2.0.4 Software

    4th step:- This menu allows to configure one or more 3 OSPF Areas (3 Areas

    max)

    47

  • Alcatel 9400 AWY version 2.0.4 Software

    5th step(protection schemes ):-

    This step exists in configuring 1+1 HSB protected link.

    1+1 HSB = 2 ODUS with the same frequency, 2 IDUS (for backup

    MUX/DEMUX), and 2 IF cables

    48

  • Alcatel 9400 AWY version 2.0.4 Software

    5th step(protection schemes ):-

    Revertive & Non Revertive:-

    Suppose that we have 1+1 link, and we have failure in the main unit, then the

    extension unit is the active one and responsible for transmission and reception

    from the other site.

    If you take the corrective action for the main unit and it is now ready to carry

    traffic and will be responsible for transmission and reception from the other site,

    then if it is automatically carries the traffic then this operation type is Revertive

    but if you activated the main unit to carry traffic manually, then the operation

    type will be Non Revertive

    49

  • Alcatel 9400 AWY version 2.0.4 Software

    6th step:- This menu allows to enter the local IP address, and to Enable or

    Disable the Ethernet configuration in case there is Ethernet Interface (optional).

    50

  • Alcatel 9400 AWY version 2.0.4 Software

    7th step:- This menu allows to configure the IP point to point interface (RF,

    V11,G703 )interfaces.

    51

  • Alcatel 9400 AWY version 2.0.4 Software

    8th step:- This menu allows to complete the IP configuration(static Routing

    configuration),

    52

  • Alcatel 9400 AWY version 2.0.4 Software

    9th step:- This menu allows to configure the Auxiliary interface and EOW through

    the order wire configuration and the auxiliary interface configuration

    53

  • Alcatel 9400 AWY version 2.0.4 Software

    10th step:- This menu allows to complete the external point configuration.

    In case you connect the site external alarms to the microwave as

    Power, door, ACS, high temp alarm instead of connecting this alarms to the bts

    54

  • Alcatel 9400 AWY version 2.0.4 Software

    Last step:- This menu summarizes all the parameters configured during this

    procedure and some relevant parameters with default values.

    55

  • Alcatel 9400 AWY version 2.0.4 Software

    1.6)profile management:-

    This menu allows to change the username and the password of the software used

    and to control the users (restricted).

    56

  • Alcatel 9400 AWY version 2.0.4 Software

    2) Diagnosis:-

    In this menu we have six options which are available as shown

    2.1-Alarms 2.2-Log Browsing 2.3-Remote Inventory

    2.4-Abnormal condition list 2.5:-Summary Block Diagram View

    2.6-Current Configuration View

    57

  • Alcatel 9400 AWY version 2.0.4 Software

    2.1)Alarms:-

    This menu allows the management of the NE alarms(their type severities).

    We can open the NE alarms as shown below

    58

  • Alcatel 9400 AWY version 2.0.4 Software

    WE have 3 categories of NE alarms (equipment, external and transmission

    alarms)

    The Equipment and Transmission alarms are classified as Communication alarm

    1- equipment alarms : as Internal communication problem, Cable los, High BER

    and PPP fail

    2-external: In case you connect the site alarms within the microwave as door

    ,high temp and power alarm ( but not used in our network)

    3- Transmission alarms : as loss of signal alarm for the free ports , AIS alarm

    the next table will describe an example of NE alarms including their types,

    severity and the time of the alarm , and if this alarm cleared or not.

    59

  • Alcatel 9400 AWY version 2.0.4 Software

    60

  • Alcatel 9400 AWY version 2.0.4 Software

    2.2) Log Browsing:-

    This menu is Divided into 2 submenus which are

    2.2.1)Alarm Log Display 2.2.2)Event log Display

    2-Alarm log Display: Display all the alarms stored in the NE including full alarm

    data (type, severity ,time).

    1- Event log display : The Event Log window analyze all the events stored in the

    NE.

    Note that

    This menu is very important in case of the unstable links as you can open this

    menu to determine All the alarms and events stored in the NE ,hence you

    can take your corrective action to clear your alarms and the link will be stable

    again.

    61

  • Alcatel 9400 AWY version 2.0.4 Software

    How to open The Log Browsing menu?

    62

  • Alcatel 9400 AWY version 2.0.4 Software

    2.2.1) Alarm log Display Menu

    From this window we can display all the alarm data (time, type of alarm)

    Also you can filter any type of alarms you want to display it , you can filter

    the major, minor and critical alarms .

    63

  • Alcatel 9400 AWY version 2.0.4 Software

    2.2.1) Alarm Log Display:-

    After we select Filter , we will wait for downloading the alarm report as shown

    below.

    64

  • Alcatel 9400 AWY version 2.0.4 Software

    2.2.1 Alarm Log Display:-

    Then we will see the alarm report , we can save this report as PDF file,

    XML File.

    65

  • Alcatel 9400 AWY version 2.0.4 Software

    2.2.2) Event Log Display:-

    This menu analyze all the events stored in the NE. The Event report is shown

    below.

    66

  • Alcatel 9400 AWY version 2.0.4 Software

    2.3) Remote Inventory:-

    This menu shows all the information on the equipment as part number

    serial number

    This menu helps you incase the link is down, and the site contains many

    microwaves and you want to identify your microwave link from this many

    Dishes, you can use the remote inventory to identify the serial Number of the

    ODU , then you begin to take the corrective action.

    Remote inventory is opened as shown below:

    67

  • Alcatel 9400 AWY version 2.0.4 Software

    2.3) Remote Inventory:-

    Remote inventory menu is shown below.

    68

  • Alcatel 9400 AWY version 2.0.4 Software

    2.4) Abnormal condition list:-

    This menu displays the abnormal conditions made manually as:-

    1- TX muting 2-Loopback 3- switching commands (forced,lockout)

    The abnormal condition list opened as shown below

    69

  • Alcatel 9400 AWY version 2.0.4 Software

    2.4) Abnormal condition list:-

    After you click on the abnormal condition list .

    suppose that we Make a loopback, this will give an abnormal condition as shown

    below.

    70

  • Alcatel 9400 AWY version 2.0.4 Software

    2.5) Summary Block Diagram View:-

    This menu displays the alarms and the status present on link from the 2 sites

    as loopbacks, switching and alarms in the IDU and ODU.

    The summary Block Diagram View depends on the configuration if it is

    1) 1+0 2 )1+1 HST (2IDU, 2ODU,2 IF cable and same frequency)

    The summary block Diagram is opened as follow.

    71

  • Alcatel 9400 AWY version 2.0.4 Software

    2.5) Summary Block Diagram View:-

    For The 1+0 Configuration, The block diagram will be as follow:-

    72

  • Alcatel 9400 AWY version 2.0.4 Software

    2.5) Summary Block Diagram View:-

    For The 1+1 HSB Configuration, The block diagram will be as follow:-

    IDU loop of ch 1

    IDU loop of ch 0

    ODU loop of ch 1

    RF loop of ch 1

    RF loop of ch 0

    tributary loop

    of ch 1

    tributary loop

    of ch 0

    73

  • Alcatel 9400 AWY version 2.0.4 Software

    2.6) Current Configuration View:-

    This menu shows the current configuration of the NE ( read only file),

    you can save this file on your laptop in case you make data collection for

    microwaves on site , this will help you in case this link is down because you

    saved the configuration file on your laptop before.

    we can open current configuration view as shown below.

    74

  • Alcatel 9400 AWY version 2.0.4 Software

    2.6) Current Configuration View:-

    after you click on the current configuration view , you will receive the following

    file.

    75

  • Alcatel 9400 AWY version 2.0.4 Software

    3) Supervision:-

    This tab is responsible for the supervision and management system within the NMS

    interfaces ; this menu is divided into four submenus as:-

    3.1)Access State 3.2)Restart NE 3.3)MIB Management

    3.4)SW key

    this menu can be opened as shown below.

    76

  • Alcatel 9400 AWY version 2.0.4 Software

    3.1) Access state:-

    This menu allows or inhibit NE craft access , this menu is divided into 2

    submenus which are 1)OS 2)Requested

    1)OS : access denied, this means that OS only manages the NE and can make changes in the link configuration ,as the craft terminal can read only the NE

    configuration without modification in it

    2)Request: This menu is to inform that the craft terminal can also manage the

    NE operations and configuration with the OS

    Note that:-

    In case you go to the site and you want to change something in the configuration

    as raising TX power for example, but you find that you cannot make this action ,

    this means that access denied or the access state in the OS

    then select the access state to be requested or call the NMS server to allow your

    access,

    Other solution:- You can remove the NMS Cabling , and then Reset the IDU, then

    you can take your actions, then put the NMS cables again to be managed again

    77

  • Alcatel 9400 AWY version 2.0.4 Software

    3.1)access state :-

    In case the access state is OS as shown below.

    78

  • Alcatel 9400 AWY version 2.0.4 Software

    3.1)Access state:

    In case the access state is requested.

    79

  • Alcatel 9400 AWY version 2.0.4 Software

    3.2)Restart NE:-

    This menu allows a software reset for the NE ,also it can be executed without

    affecting the traffic.

    this menu can be opened as shown below.

    80

  • Alcatel 9400 AWY version 2.0.4 Software

    3.2)Restart NE:-

    from the previous slide , when you click on restart NE the following message appears as shown , then you select yes

    81

  • 3.3)MIB Management (Management Information Base):-

    The MIB Management includes all the system configuration data, except the

    routing configuration data as IP Configuration ,NTP Server Configuration

    MIB Management includes 4 submenus :-

    3.3.1)Back up 3.3.2)Restore 3.3.3)Remove file 3.3.4)Activate

    The MIB Management menu can be opened as follow:-

    Alcatel 9400 AWY version 2.0.4 Software

    82

  • 3.3.1)Back up:-

    This menu allows to save on the craft terminal the NE Configuration

    Alcatel 9400 AWY version 2.0.4 Software

    Step 1

    The file name will include

    your back up file you want

    to create as

    1+1configuration 16 E1, then the confirm back up tab will be activeStep 2

    Click on confirm back up to start the

    operation

    Step 3

    Press the Refresh button and the new

    back up file will appear

    after step 3

    The new file 1+1 configuration 16 E1

    will appear here

    83

  • Alcatel 9400 AWY version 2.0.4 Software

    3.3.2)Restore:-

    This menu allows to download the previously created backup file to the NE

    Here we should

    have the new file

    1+1 configuration,16E1

    , and confirm Restore is active

    After confirm Restore is active, press on it to start downloading

    the previously created

    backup file to the NE

    84

  • Alcatel 9400 AWY version 2.0.4 Software

    3.3.3)Remove file:-

    This menu allows to remove the file, You just downloaded in the previous step

    confirm Remove is to remove the file

    just downloaded

    85

  • Alcatel 9400 AWY version 2.0.4 Software

    3.3.4) Activate :-

    This menu allows to activate the configuration just down loaded in the restore file menu

    (2nd step)

    Click on yes to activate the

    preloaded

    backup file

    86

  • Alcatel 9400 AWY version 2.0.4 Software

    3.4)SW key:-

    This menu reads the information about the key plugged into the main IDU

    The SW key menu can be opened as follow:-

    87

  • Alcatel 9400 AWY version 2.0.4 Software

    4)SW Download:-

    This menu contains the flash card software status and versions installed in this

    flash cards.

    This menu is divided into 3 submenus which are:-

    1)Server Access Configuration 2)Init SW download

    3)SW Status

    88

  • Alcatel 9400 AWY version 2.0.4 Software

    4.1)Server access configuration:-

    This server used to speed up the software downloaded to the NE.

    Server access configuration can be opened as shown below.

    89

  • Alcatel 9400 AWY version 2.0.4 Software

    4.1)Server access configuration:-

    When press on server access configuration from the previous slide, then this

    menu appears

    90

  • Alcatel 9400 AWY version 2.0.4 Software

    4.3) Software status:-

    This menu allows to display the information of the software installed in the

    we can install 2 software versions in the NE as shown below.

    2 software

    version are

    installed

    Committed means

    that this software

    version is currently in

    use

    91

  • Alcatel 9400 AWY version 2.0.4 Software

    4.3) Software status:-

    How to activate the other installed software ?Press on 2

    Form software management action

    press activation then

    Press apply action

    After you press apply the software

    will be activated but you should

    reconfigure the link again

    92

  • Alcatel 9400 AWY version 2.0.4 Software

    4.3) Software status(compatibility between SW versions and ODUS versions):-

    suppose that we have a faulty ODU and we need to replace it by new one,

    after you replace this ODU with new one, alarm is not cleared and other new alarms

    appeared as Replaceable unit type mismatch alarm or non understandable alarm as 1.11.111.121.112.11 or High BER , this indicates that the ODU Version is not compatible with the software version installed on the flash card

    to solve this problem you have 3 choices:-

    1)activate the other software version installed on the flash card , this version may be

    compatible with the new ODU and reconfigure the NE again.

    but incase the NE contains 1 software version or the other software version is also not

    compatible with the new ODU version , then:-

    2)replace the ODU with other one compatible with the installed software version

    3) change the flash card with other one compatible with the ODU

    93

  • Alcatel 9400 AWY version 2.0.4 Software

    After introducing the equipment configuration, supervision we are going to

    describe the Equipment hardware itself through the equipment menu

    Equipment:-

    This menu describes the microwave hardware , alarms , configuration and remote

    inventory

    We can open this menu as shown below (Equipment of 1+0 link)

    94

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment:-

    Equipment menu in case of 1+1 HSB configuration (2 ODUS, 2 IDUS)

    95

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment menu (alarms tabe):-

    The alarm menu indicates the alarms exists on the microwave hardware (IDU and

    ODU) , we have a coloured ball exists on the IDU and ODU known to indicate

    the status of the IDU and the ODU

    This colour differs indicates the severity of the alarms as follow:-

    Green :No alarms

    Cyan : Warning alarm active

    Yellow : Minor alarm active

    Brown: Major alarm active

    Red: Critical alarm active

    We can open the equipment alarm as shown in the next slide

    96

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment menu:-

    Alarms tabe can be opened as follow

    97

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment(Alarm Tab):-

    Equipment menu in case of 1+1 HSB configuration (2 ODUS, 2 IDUS)

    98

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment menu (Configuration tabe):-

    This tabe indicates the alarms profile for the selected node, also you can change

    this alarm profile from this menu

    99

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment (Configuration tab):-

    IN case of 1+1 HSB .

    100

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment menu (Remote Inventory tab):-

    This menu includes all information about the equipment as part no, serial no

    ,company identifier, this menu can be opened as shown below

    101

  • Alcatel 9400 AWY version 2.0.4 Software

    Equipment menu (Remote Inventory tab):-

    In case of 1+1 HSB

    102

  • Alcatel 9400 AWY version 2.0.4 Software

    External points menu:-

    This menu is necessary in case you connected the site external alarms as

    (power, high temperature alarm, rectifier alarm, Fire alarm, Door alarm and

    AC alarm ) instead of connecting this alarms to the BTS or the BSC.

    This menu is classified into :-

    1)Input External Points 2)Output External points

    We have 6 input external points and 7 output external points.

    103

  • Alcatel 9400 AWY version 2.0.4 Software

    External points menu (Input tabe):-

    This menu can be opened as shown below

    104

  • Alcatel 9400 AWY version 2.0.4 Software

    External points menu (Output tabe):-

    This menu can be opened as shown below

    105

  • Alcatel 9400 AWY version 2.0.4 Software

    Line Interface:-

    This menu allows the user to manage the PDH NMS Interfaces and the tributary

    ports interface, This menu is divided into :-

    1) NMS Interface 2) Tributaries Interface

    Line interface menu can be opened as shown below

    106

  • Alcatel 9400 AWY version 2.0.4 Software

    Line Interface (NMS Interface tab):-

    This menu includes the supervision NMS Interfaces, Alarms of this interfaces

    and the alarm profiles, you can change the severities of alarm profiles

    This menu can be opened as shown below

    107

  • Alcatel 9400 AWY version 2.0.4 Software

    Line Interface (Tributary Interface tab):-

    This tab gives information related to the tributaries as:-

    Interface type(E1,E3)

    Port number

    Channel number in case of 1+0 and 1+1 HSB configuration

    Rate/Modulation : bit rate of the tributary

    Signal Mode: indicates type of frame (unframed/framed/disable)

    Line RAI insertion: refers to insertion of the RAI(remote alarm indication)signal in TX side.

    Radio RAI Insertion : refers to insertion of the RAI signal in RX side.

    Alarm profile : indicates the severity of the alarm( primary alarm)

    108

  • Alcatel 9400 AWY version 2.0.4 Software

    Line Interface (Tributary Interface tab):-

    The tributary Interface tab can be opened as shown below

    109

  • Alcatel 9400 AWY version 2.0.4 Software

    performance:-

    This menu allows the user to activate and monitor the performance monitoring

    process which gives indication on the quality of service , the performance menu can be opened as shown below

    110

  • Alcatel 9400 AWY version 2.0.4 Software

    Performance (threshold table):-

    This tab shows how to see or change the threshold values assigned to

    performance monitoring counters

    we have four supported counters 1) errored seconds:ES

    2)Severely Errored seconds : SES 3)Background block Error:

    BBE

    4)Unavailable seconds:UAS

    note that we have 2 types of threshold tables

    1)threshold table hop 2)threshold table link

    also we have 2 types of performance monitoring 15 min & 24 hr for both types

    of threshold tables (hop and link)

    111

  • Alcatel 9400 AWY version 2.0.4 Software

    1)Performance (threshold table Hop ):-

    from the threshold menu you can create the threshold value assigned to pm

    counters (ES,SES,BBE) as shown below

    Threshold

    table

    creationWrite the

    low and

    high

    thresholds

    for the

    counters

    112

  • Alcatel 9400 AWY version 2.0.4 Software

    1)Performance (threshold table Hop ):-

    as we can see in the picture below you can change the threshold values

    assigned to PM (performance monitoring) counters

    Threshold table

    configuration

    113

  • Alcatel 9400 AWY version 2.0.4 Software

    1)performance (hop tab):-

    we have 2 types of performance monitoring 1)15 min performance monitoring

    2)24 h performance monitoring

    also we have 2 types of reports for threshold hop 1)CD: current data report

    2)HD: history data report

    for each type of performance you will have the 2 types of reporting (CD & HD)

    Two hoping coz

    we have 1+1

    HSB configureThe 2 types

    of pm

    includes the

    2 types of

    reports

    114

  • Alcatel 9400 AWY version 2.0.4 Software

    performance (hop tab):-

    In case of 15 min performance monitoring the current data (CD) will be opened

    as shown below

    Current data view

    allows to start and

    to read 15 min pm

    report

    115

  • Alcatel 9400 AWY version 2.0.4 Software

    performance (hop tab):-

    In case of 15 min performance monitoring the History data (HD) will be opened

    as shown below

    History data

    view collects

    history data for

    15 min pm

    116

  • Alcatel 9400 AWY version 2.0.4 Software

    performance (hop tab):-

    In case of 24hr pm, current data report will be shown as below

    117

  • Alcatel 9400 AWY version 2.0.4 Software

    performance (hop tab):-

    In case of 24hr pm, History log report will be shown as below

    118

  • Alcatel 9400 AWY version 2.0.4 Software

    2) performance (threshold table link):-

    This type of threshold table appears only in 1+1 HSB configuration, from the

    threshold menu you can create the threshold value assigned to pm counters

    (ES,SES,BBE) as shown below

    , the threshold table link menu can be opened as shown below

    You can create the

    threshold low and high

    values through this

    menu

    119

  • Alcatel 9400 AWY version 2.0.4 Software

    2) performance (threshold table link):-

    the 2 types of performance monitoring (15 min, 24hr ) , we have 2 types of reports

    (CD & HD), CD: is the current data report taken for both pm( 15 min, 24 hr)

    in the picture below , we can observe the current data report CD within 15 min pm

    120

  • Alcatel 9400 AWY version 2.0.4 Software

    2) performance (threshold table link):-

    In case of 24hr pm, History log HD report will be shown as below

    121

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio:-

    This menu allows the user to manage the resources of the radio transmission

    channels (channel no, modulation type, TX and RX frequencies, TX power and

    ATPC).

    This menu contains 5 tab panels which are :-

    1)alarms :shows active alarms

    2) Configuration: configure some radio parameters

    3)frequency: sets the TX/RX frequency.

    4)RTPC and ATPC: sets the transmission operations.

    5)power measurements: sets the TX and RX power measurements

    122

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio:-

    For 1+0 configuration : we have channel 1 only

    For 1+1 configuration : we have cannel 1 (main unit) and channel 0 (extension

    unit)

    Radio menu for 1+0 non protected link can be opened as follow

    123

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio:-

    For 1+1 configuration : we have cannel 1 (main unit) and channel 0 (extension

    unit)

    Radio menu can be opened as follows

    124

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Alarms tab):-

    This tab includes the fault management and the active alarms on the microwave,

    same menu in 1+1 HSB Configuration , Its menu can be opened as shown

    below.

    125

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Configuration tab):-

    This menu includes information related to the transmitter status through the

    TX Mute function , this menu can be opened as follows.

    same menu will be opened in 1+1 HSB Configuration

    126

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (frequency tab):-

    This tab can be opened as shown below (explaining this tab at next slide)

    same menu will be opened in 1+1 HSB Configuration

    127

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (frequency tab):-

    This menu indicates the TX and RX frequency , also it describes the shifter

    Shifter = TX frequency- RX frequency

    Shifters are variable according to the operating frequency , the table below shows frequency and the related shifter.

    TX Frequency range: is the range of frequency written on the ODU unit, in case

    you have a faulty ODU unit and you need to change it, the new ODU should be

    Within this range

    128

    Frequency Band Shifter

    23 GHZ 1008 MHZ

    25 GHZ 1008 MHZ

    38 GHZ 1260 MHZ

    8 GHZ 126 , 154, 162 MHZ

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (RTPC & ATPC tab):-

    This menu allows to read and set the TX power parameters.

    ATPC means automatic transmitted power control, RTPC means range transmitted power

    control. same menu will be opened in 1+1 HSB Configure

    same menu will be opened in 1+1 HSB Configuration

    129

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab):-

    This menu allows to read the Power level (TX & RX) for the local and the Remote

    stations , This menu can be opened as follows

    130

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab)for 1+0 non protected link:-

    After you press start , you will find a graphical representation for the TX & RX

    levels for both local and remote site, then click on show details to have a table indicating

    these levels with their maximum , minimum and current states

    TX local end

    :transmitted power at

    your site

    TX far end: transmitted

    power from the

    remote site

    RX local end : received

    power at your site

    RX far end : received

    power at remote site

    131

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab)for 1+1 HSB protected link:-

    for the 1+1 HSB protected link, we have 2 channels:-

    channel 1 for main unit and channel 0 for extension unit, the two units are connected

    together through b2b connection within the IDUS(MUX/DEMUX)protection and coupler

    within the ODU

    this coupler makes a difference of 10 db between the main and the extension units

    Note that:-

    IF the extension unit is acting as the active unit for site A in the HST TX protection, then

    the main and extension unit at the other site(site B) will have received level decreased by

    10 db rather than the main unit is the active unit transmission in site A .

    RX level at channel0= RX level at channel 1-

    10db

    132

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab)for 1+1 HSB protected link:-

    Form the 2

    tables, we found

    that RX at main

    unit ch1=-47.9,-

    48.5 for the

    local and far

    ends

    respectively,

    While for the

    extension unit

    ch0 we found

    that RX at local &

    far ends=-57.8,-

    56.4

    TX is stand by

    in ch0 for both

    local & far ends

    TX is active in

    ch1 for both

    local & far

    ends

    133

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab):-

    How to read a power measurement file?

    Suppose that you have an unstable link , and you want to determine the power

    level variation ,then you should follow this steps:-

    1- click on Read File , then press select file as shown

    134

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab):-

    after you select file then the directory of the ct will open automatically as shown

    step 2: 2- select the desired file and click open to open this file as shown.

    135

  • Alcatel 9400 AWY version 2.0.4 Software

    Radio (Power Measurement tab):-

    step 3: A WordPad file of the TX & RX levels appears as shown below.

    136

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes:-

    This Menu displayed only in protected 1+1 HSB microwave links for managing

    the switching between ch1 & ch0, the protection schemes menu can be opened

    as

    137

  • Protection schemes:-

    The protection schemes menu is divided into 3 main tabs which are:-

    1)Mux/ Demux 2)HST TX protection 3) Radio Protection.

    the block diagram shown below explain the 3 protection schemes.

    Alcatel 9400 AWY version 2.0.4 Software

    Mux

    protection

    HST TX

    PROTECTION

    dDemux

    protection Radio protection

    138

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes:-

    1)Mux/ Demux protection: protection in TX/RX side towards the IDU

    Mux protection in TX SIDE, Demux protection in RX side

    2)HST TX protection: transmission protection towards the ODU side

    3) Radio Protection: Hitless Receiver protection.

    The three protection schemes operation type indicates if there is automatic

    restoration criteria or not through Revertive and Non Revertive operation

    If Revertive then we have automatic restoration and Non Revertive then we have manual restoration

    Revertive & Non Revertive well explained in slide 49

    139

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes:-

    for the 3 schemes , there is a list of commands you should know for modification the state

    of switching between the main and extension units

    1) Lockout : this commands equals to switching off the unit, suppose that you apply lock out command on the extension unit , then if the main unit became faulty , then the link will

    be down no protection available due to locking out command of ch0 , Gives abnormal condition indication, lock out command is available for the standby unit

    2)Forced :to force the protection on one unit only, suppose that the main unit suffers from

    HIGH BER then you can force the protection to the extension unit , then if you take the

    corrective action for the main unit and HIGH BER alarm cleared, the extension

    unit still the active unit due to the forced command , Gives abnormal condition indication, forced command is available for the active unit,

    active unit ch1+forced command= spare unit ch1

    3)Automatic switch: normal switching operation condition

    4)Manual : this command cannot be performed if forced or lock out commands is already

    active, rarely used command

    140

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Mux/Demux protection):-

    Automatic

    restoration will

    takes place

    Main unit is active and the

    extension unit its backup

    for protecting Mux/Demux

    Automatic switching normal condition

    141

  • Protection schemes (Mux/Demux protection):-

    In case of the lock out command

    Alcatel 9400 AWY version 2.0.4 Software

    Select lock out and then press

    apply

    142

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Mux/Demux protection):-

    in case of forced command

    Select forced

    and then press

    apply

    143

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (HST TX):-

    Automatic

    restoration

    Main unit is the active

    unit which means main

    ODU only transmits to

    the other site , but

    the extension unit is

    stand by

    144

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (HST TX):-

    In case of lock out command : lock out command is available for the standby

    channel only i.e ch0

    145

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (HST TX):-

    In case of forced command: the forced command is available only for the active

    unit i.e ch1

    Forced command is available

    for the active channel, to force

    the transmission on stand by

    ODU ch0

    Select Forced and then press apply

    146

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (HST TX):-

    In case of forced command: the forced command is available only for the active

    unit then the main unit will be the spare unit as we can see that in the previous

    slide, the main unit ch1 was active but when applying forced command it

    became the spare unit as shown below

    147

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (HST TX):-

    from the previous slide, we can observe that the main unit ch1 became the stand

    by after applying the forced command on it, the table below shows

    the power measurement for ch1 after applying the forced command

    No TX power for the

    local end due to forced

    command indicating

    abnormal condition

    RX far end became -

    63 because the

    extension unit ch0 is

    the active unit in

    transmission and

    there is -10 db

    difference between

    ch1 & ch0

    RX local

    end still

    -53 coz

    ch1 at

    remote

    site is

    the

    active

    unit

    148

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    Radio protection means receiver protection ,it includes 3 main tabs

    1)Alarms 2)protection scheme parameters 3)RX static delay

    Automatic

    restoration for the

    receiver

    protection

    Automatic

    normal

    condition

    :main unit is

    active and

    extension unit

    is spare

    149

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    1)Alarms:-

    The most common alarm observed on the radio protection is Loss of alignment

    this alarm takes place in case there is failure any unit (main unit or extension)unit

    this means that there is no radio protection and there will be receiver delay because the

    other unit is faulty, to solve this problem

    take the corrective action towards the faulty unit so that the link became 1+1 protected link

    and then activate the hitless switch radio protection by aligning the RX static delay

    through the automatic operation

    next slide shows how to clear the Loss of alignment through the RX static delay

    150

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    3)RX static delay menu can be opened as shown below.

    To clear the loss of alignment alarm click

    on RX static delay tab

    and press align to

    activate the

    automatic operation

    for the hitless switch

    151

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    the switching commands are available for the Radio protection:-

    1)Lock out: lock out command is available for the standby unit, an abnormal condition

    appears when lock out command is active.

    2)forced command: forced command is available for the active unit to change it

    to the standby, an abnormal condition appears when forced command is active

    3)Automatic switching (None): is the normal switching condition

    switching commands are well explained in slide 140.

    152

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    IN case of lock out command, you will have this menu:-

    153

  • Alcatel 9400 AWY version 2.0.4 Software

    Protection schemes (Radio protection):-

    IN case of automatic switching None command is used to remove the lock out

    command in the previous slide , select None and then you will have this menu

    154

  • Alcatel 9400 AWY version 2.0.4 Software

    Loopback:-

    You can use this menu to do the following:-

    1)IF you have communication alarm between the 2 sites as High BER, demodulator fail, modulator fail , RX fail you can use the RF loop back to

    decide weather the fault is on your local site or from the remote site such that

    IF you make RF loop and the alarms cleared and you have normal received

    level then the problem will be on the other site

    2)IF you have transmission alarm as AIS for a tributary carries a bts, and this

    bts suffers from AIS, you can use tributary loopback to check the route

    3)checking equipment (IDU, ODU , CONNECTORS AND IF CABLE)

    155

  • Alcatel 9400 AWY version 2.0.4 Software

    Loopback:-

    WE have 6 types of loopbacks in both 1+0 configuration and 1+1 HSB configuration:-

    1)RF loopback: is to check the total path including( IDU, IDU CONNECTOR, IF

    CABLE,ODU CONNECTOR, ODU)

    2)ODU loopback: to check the path before ODU including (IDU,IDU CONNECTOR, IF

    CABLE, ODU CONNECTOR)

    3) IDU loopback: to check the IDU equipment

    NOTE that :in case you activate any loop of the previous 3 loopbacks : the link will be

    down and you will effect traffic.

    4)tributary loopback (E1-TX port x NE): input loop back at the tributary

    5) tributary loopback (E1-RX port x NE): loopback towards the remote station at a

    tributary , but this loopback is not available.

    6)tributary loopback (E1- RX port x FE): loopback at the tributary in the remote

    station.

    activation of any loopback of the previous loopbacks will indicate an abnormal condition

    in the NE.

    156

  • Alcatel 9400 AWY version 2.0.4 Software

    Loop Back in 1+0 non protected link:-

    Tributary input

    loopback at your

    local station

    Near END

    IDU LOOP to check the

    IDU

    Equipment

    ODU LOOP

    To check the path

    from the IDU to

    the ODU Connector

    RF LOOP

    To check the whole

    path and to indicate

    if the problem is in

    your site or in the

    remote site

    Tributary

    loopback at

    the Remote

    station Far END

    157

  • Alcatel 9400 AWY version 2.0.4 Software

    loop back:-

    How to open the loopback menu ?

    Trtributary loop

    back at local site

    IDU loopback

    Tributary loop back

    towards remote site

    not available loop

    ODU

    LOOP

    BACK

    RF

    Loop

    back

    Tributary loop back

    at the remote

    station

    158

  • Alcatel 9400 AWY version 2.0.4 Software

    loop back:-

    How to activate any loopback ?

    assume that we will make RF loop so you will follow the following steps as shown below

    any loop can be activated by the same method

    Select

    RF and

    then

    press

    Active

    Abnormal

    condition

    list

    indicates

    RF loop back and

    AC became

    Blue

    colored

    159

  • Alcatel 9400 AWY version 2.0.4 Software

    loop back in 1+1 HSB protection:-

    we have additional 3 loops than 1+0 non protected ,these 3 loops performed

    through ch0 (extension unit).

    Note that :-

    you cannot activate any loops of ch0 if it is not the active unit

    therefore you can make (RF,IDU,ODU)loops of ch0 ,when ch0 is the active unit

    ie active in (TX , Radio protection and Mux/ Demux protection)

    160

  • Alcatel 9400 AWY version 2.0.4 Software

    2.5) Summary Block Diagram View:-

    For The 1+1 HSB Configuration, The block diagram shows loopback available at 1+1 HSB

    IDU loop of ch 1

    IDU loop of ch 0

    ODU loop of ch 1

    RF loop of ch 1

    RF loop of ch 0

    tributary loop

    of ch 1

    tributary loop

    of ch 0

    ODU loop of ch0

    Tributary loop of

    ch1 at remote site

    Tributary loop of

    ch0 at remote site

    161

  • 3)Alarms Handling:-

    In this section we are going to describe the alarms and how to clear it,

    the most common repeated alarms is :-

    1)High BER

    2)Modulator fail

    3) Demodulator fail

    4)RX fail

    5) TX fail

    6)modulator los

    7)demodulator los

    8)loss of frame

    162

  • 3)Alarms Handling:-

    to solve any of this alarms you should follow the following steps:-

    1)Make RF loop to decide if the problem is in your site or in the remote site

    if the alarms cleared and you have acceptable RX level at your local station

    then go to the other site and do the following, you will make another RF loop

    and this alarms will not be cleared then the problem will be on your site

    to solve this problem follow this steps

    2) check the connectors and the IF cable carefully ,then

    3) Replace ODU after you checked the connectors and the IF cable

    4) if the problem still exists then try to change the IDU and alarm will be cleared

    from the previous steps you can solve the mentioned alarms in the previous

    slide

    5)next slide will show you how to replace ODU?

    163

  • 3)Alarms Handling:-

    How to replace ODU?

    Suppose that we have a 1+1 HSB link and we need to replace the extension

    ODU

    1st step: switch off the extension IDU as shown below,

    Extension

    unit is

    switched off

    164

  • 3)Alarms Handling:-

    2nd step remove the connector of the extension ODU as shown below.

    before removing the connector after the connector removed

    Before

    removing the

    connector

    from the

    extension

    unit

    165

  • 3)Alarms Handling:-

    3rd step plugged out the faulty extension ODU and determine the polarization

    towards the antenna for the new ODU as shown below and prepare the new

    ODU .

    Faulty ODU is

    plugged out

    and we have

    vertical

    polarization

    Connector is

    plugged here for

    the new ODU

    166

  • step 4: plug in the new ODU very well , and then put the IF connector as shown

    below.

    plugging in the New ODU IF connector is plugged in the ODU

    step 5: switch on the extension IDU

    3)Alarms Handling:-

    167

  • How to change IDU?

    1st step :switch off the IDU as shown below

    3)Alarms Handling:-

    IDU is

    switched

    off

    168

  • 2nd step: plug out all the cables (power, interfaces & IF) from their slots as shown

    below.

    3)Alarms Handling:-

    interfaces

    cables

    removed

    Upper slot

    indicates

    from 9 to

    16

    tributaries

    And the

    lower slot

    indicates

    from 1 to 8

    tributaries

    If cable

    removed

    from

    IDU

    169

  • 3rd step : plug out the flash card located at the back of the IDU

    last step: plug in the flash card into the new IDU carefully

    last step: switch on the IDU after you plugged in all the cables(power, interfaces & IF)

    3)Alarms Handling:-

    Plug in the flash

    card carefully to

    the new IDU

    170

  • other alarms:-

    1)cable los: check the 2 IF Connectors and the IF cable carefully, if the problem still exists

    ,change IDU unit, then ODU if the problem still exists.

    2)alarm replaceable unit type mismatch or 1.11.11.12.21 : ODU version is not compatible

    with the software version installed on the flash card , to solve this problem you can do the

    following a)change the new ODU with other one compatible with the flash card software

    version b) activate the 2nd software version it may be compatible with the ODU

    version and then reconfigure the link again

    c)change the flash card with other one and its software version is compatible with the

    new ODU

    3)Internal communication problem: check the connectors, then IDU

    4)los of alignment: a problem in the radio protection switching , this alarm appears in 1+1

    HSB Configuration only, to solve this problem see slide 150

    5)incompatible shifter: apply the right shifter value for the operating frequency see slide

    127

    3)Alarms Handling:-

    171

  • some problems may cause HIGH BER alarms and loss of frame:-

    1)alignment problem : the reason of this problem is bad weather conditions or the support

    carrying the microwave is not well fixed , such that the RX level at both sites is not stable

    this will cause High BER alarm

    How can you identify that this BER alarm is due to alignment problem?

    a)check the equipments at the two sites through RF loopback, then you will have

    acceptable RX levels and alarms cleared this indicates that the equipments is good

    b)open the power measurement table and monitor the RX levels for local and far ends

    with their minimum, maximum and current values

    c) the Rigger Must check that the line of sight is clear and there is no obstacles.

    to solve this problem try to realign the link from the 2 sites using alignment tools to give

    the best RX level at both sites, thus the BER alarm cleared and link is

    3)Alarms Handling:-

    172

  • some problems may cause HIGH BER alarms and loss of frame:-

    2)Wave guide problem:-

    the wave guide is rarely used in our network , this wave guide is used in nonintegrated

    antenna, any cut in this wave guide will effect the RX levels at local and far end to be very

    weak about -77 db which causes high BER

    to solve this problem

    Replace the wave guide with other one such that the RX level will be normal again and

    the BER alarm will be clear

    3)Interference problem:

    This problem occurred when there is two microwave links have the same alignment and

    same frequency, this will gives an interference problem leading to high BER alarm

    3)Alarms Handling:-

    173

  • some problems may cause HIGH BER alarms and loss of frame:-

    3)Interference problem:

    How can you identify the interference problem ?

    1)switch off the transmission from your site and try to observe the RX level at the

    remote site , you will have RX level (this RX level is not from your opposite site)

    but this is due to interference problem with other link

    2) switch off the transmission form the remote site and try to observe the RX

    level at your local site, you will have RX level (this RX level is not from your

    opposite site) but this is due to interference problem with other link.

    from 1 & 2

    you will observe that when you switch off transmission from any site, the other

    site will receive signal , this means that there is interference problem

    3)Alarms Handling:-

    174

  • some problems may cause HIGH BER alarms and loss of frame:-

    How to solve Interference problem?

    a)avoid installation of links having the same alignment and frequency

    b) using default frequencies : this frequencies can overcome the interference

    problem the table below shows the default frequencies can be used for mobinil

    bands.

    3)Alarms Handling:-

    175

    Band Frequency high Frequency low

    BAND 23 GHZ 23254000 22246000

    Band 25 GHZ 25781000 24773000

    Band 38 GHZ 38598000 37338000

  • some problems may cause HIGH BER alarms and loss of frame:-

    4)Coupler problem:-

    This problem occurs in 1+1 HSB configuration only , , if the coupler became

    faulty it may effects the RX level at both sites it will make losses about -20 db

    leading to high BER.

    how can you identify that this is coupler problem?

    a)check the equipments by RF loopback at the 2 sites.

    b)remove the coupler form 1 site and observe the RX level at both local and far

    ends, if the RX level became normal at both sites then the problem is in the

    coupler

    we can solve this problem by changing the coupler with new one and if you don't have spare available, you can remove the faulty coupler such that the link

    became 1+0 from your side, and 1+1 from the other side.

    3)Alarms Handling:-

    176