9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more...

20
pressure I N S T R U M E N T A T I O N Part of your business Pressure and Temperature Measurement

Transcript of 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more...

Page 1: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

pressure

I N S T R U M E N T A T I O N

Part of your business

Pressure andTemperature Measurement

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 1

Page 2: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Part of your businessAt WIKA, we understand that even the smallest pressure gauge is an

important part of your business. That’s why we are committed to providing

exceptionally accurate and reliable pressure and temperature measurement

solutions that meet your constantly evolving business needs.

Our commitment is demonstrated by our significant global investment in

technology, manufacturing and R&D. This investment enables us to

develop innovative products and system solutions that also offer value

for money.

WIKA’s comprehensive range of quality mechanical and electronic pressure

and temperature instrumentation includes pressure gauges, switches,

transmitters and transducers, diaphragm seals, thermometers,

thermocouples, resistance thermometers, temperature transmitters,

thermowells and accessories.

Our products are supported by onsite service and calibration, after sales

support and two instrument workshops based in Sydney and Melbourne.

These workshops specialise in producing quality, customised

products quickly.

For more than 50 years, businesses around the world have made WIKA

Alexander Wiegand GmbH & Co products part of their business. Today,

WIKA is represented in 100 countries throughout the world and has more

than 3000 employees located in over 20 countries.

In Australia, WIKA’s worldwide resources are complemented by more than

100 years of combined local experience, following the 1998 WIKA acquisition

and merger of Dobbie Instruments and Budenberg Gauges Australia.

WIKA is ISO certified and NATA accredited.

Pressure andTemperature Measurement

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 2

Page 3: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

co

nte

ntsStandard gauges two

Industrial gauges four

Process gauges six

Differential gauges eight

Safety pattern gauges nine

Oxygen gauges nine

Capsule gauges nine

Diaphragm gauges nine

Diaphragm seals ten

Pressure transmitters twelve

Calibration equipment fourteen

NATA capabilities fourteen

Test gauges fifteen

Pressure switches sixteen

Indicating pressure switches seventeen

Square and rectangular gauges seventeen

Bottle and can testers seventeen

Accessories seventeen

Pressure conversion table back page

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 3

Page 4: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Model 111.10Nominal size 40mm 50mm 63mm 63mm 100mm

Design

Case Black plastic Black steel

Mounting Direct Direct Direct Surface Directbottom bottom bottom bottom bottom

Connection 1/8"BSP taper 1/8"BSP taper 1/4"BSP taper 1/4"BSP taper 3/8"BSP taperScale range-100/0 kPa 530.9628933.10 530.9665022.10 530.9144991.10 530.9144991.11 530.15000-100/150 kPa 530.9628934.10 530.9665023.10 530.9144992.10 530.9144992.11 530.15001-100/300 kPa 530.9628935.10 530.9665024.10 530.9144993.10 530.9144993.11 530.15002-100/500 kPa 530.9628936.10 530.9665025.10 530.9144995.10 530.9144995.11 530.15003-100/900 kPa 530.9628937.10 530.9665027.10 530.9144996.10 530.9144996.11 530.150040/100 kPa 530.9628938.10 530.9665028.10 530.9144997.10 530.9144997.11 530.150050/160 kPa 530.9628939.10 530.9665029.10 530.9144998.10 530.9144998.11 530.150060/250 kPa 530.9628941.10 530.9665031.10 530.9144990.10 530.9144990.11 530.150070/400 kPa 530.9628942.10 530.9665032.10 530.9145000.10 530.9145000.11 530.150080/600 kPa 530.9628943.10 530.9665033.10 530.9145003.10 530.9145003.11 530.150090/800 kPa 530.9628977.10 530.9665046.10 530.9145016.10 530.9145016.11 530.150100/1000 kPa 530.9628944.10 530.9665034.10 530.9145002.10 530.9145002.11 530.150110/1600 kPa 530.9628945.10 530.9665036.10 530.9145005.10 530.9145005.11 530.9129855.100/2500 kPa 530.9628946.10 530.9665037.10 530.9145004.10 530.9145004.11 530.9395364.100/4000 kPa 530.9628947.10 530.9665038.10 530.9145007.10 530.9145007.11 530.150140/6000 kPa 530.9628948.10 530.9665039.10 530.9145008.10 530.9145008.11 530.150150/8000 kPa 530.9628949.10 530.9665040.10 530.9145009.10 530.9145009.11 530.150160/10x1000 kPa 530.9628950.10 530.9665041.10 530.9145011.10 530.9145011.11 530.150170/16x1000 kPa 530.9628951.10 530.9665042.10 530.9145012.10 530.9145012.11 530.150180/25x1000 kPa 530.9628952.10 530.9665044.10 530.9145013.10 530.9145013.11 530.150190/40x1000 kPa 530.9628953.10 530.9665045.10 530.9145014.10 530.9145014.11 530.15020

WIKA standard pressure gauges are designed for long and reliable service under rugged

conditions. Some typical applications include pumps, hydraulic and pneumatic systems,

compressors, and as a contractor’s gauge. The gauges can also be used for many other

applications where the measured media does not corrode brass.

WIKA standard pressure gauges feature a black plastic case (steel cases are available as an

option) and a helical Bourdon tube for 6000 kPa and higher. The low friction Swiss movement

ensures a long, reliable service life.

• Copper alloy wetted parts

• Black plastic case

• Cost effective design

Standard features

Size: 40mm, 50mm, 63mm,

100mm

Wetted parts: Copper alloy

Case: Black plastic

Window: Snap fit clear plastic

Dial: White plastic-Dual scale

kPa/psi

Pointer: Black plastic

Accuracy: ±2.5% of span

(EN 837)

Maximum process

temperature: 60ºC

Type 111.10

Page two

Data sheet PM 01.01

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 4

Page 5: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

WIKA Type 111.16 pressure gauges offer the same long and reliable

service as standard Type 111.10 gauges, but are designed for direct or

flush mounting. They feature a black plastic case and low friction Swiss

movement to ensure a long, reliable service life.

• Copper alloy wetted parts

• Black plastic case

• Gauges for direct or flush mounting

Standard features

Size: 40mm, 50mm, 63mm

Wetted parts: Copper alloy

Case: Black plastic

Window: Snap fit clear plastic

Dial: White plastic-Dual scale kPa/psi

Pointer: Black plastic

Accuracy: ±2.5% of span (EN 837)

Maximum process

temperature: 60ºC

Model 111.16Nominal size 40mm 50mm 63mm

Design

Mounting Direct Direct Directrear axial entry rear axial entry rear axial entry

Connection 1/8"BSP taper 1/8"BSP taper 1/4"BSP taperScale range-100/0 kPa 530.9628954.20 530.9617401.20 530.9145018.20-100/150 kPa 530.9628955.20 530.9617402.20 530.9145019.20-100/300 kPa 530.9628956.20 530.9617403.20 530.9145020.20-100/500 kPa 530.9628957.20 530.9617404.20 530.9145021.20-100/900 kPa 530.9628958.20 530.9617406.20 530.9145022.200/100 kPa 530.9628960.20 530.9617407.20 530.9145024.200/160 kPa 530.9628961.20 530.9617408.20 530.9175025.200/250 kPa 530.9628962.20 530.9617409.20 530.9145026.200/400 kPa 530.9628963.20 530.9617410.20 530.9145027.200/600 kPa 530.9628964.20 530.9617411.20 530.9145029.200/800 kPa 530.9628978.20 530.9617427.20 530.9145042.200/1000 kPa 530.9628965.20 530.9617412.20 530.9145030.200/1600 kPa 530.9628966.20 530.9617415.20 530.9145032.200/2500 kPa 530.9628968.20 530.9617416.20 530.9145033.200/4000 kPa 530.9628969.20 530.9617417.20 530.9145034.200/6000 kPa 530.9628970.20 530.9617419.20 530.9145035.200/8000 kPa 530.9628971.20 530.9617420.20 530.9145037.200/10x1000 kPa 530.9628972.20 530.9617422.20 530.9145038.200/16x1000 kPa 530.9628973.20 530.9617423.20 530.9145039.200/25x1000 kPa 530.9628974.20 530.9617424.20 530.9145040.200/40x1000 kPa 530.9628976.20 530.9617425.20 530.9145041.20

GA

UG

ES

sta

nd

ard

Type 111.16

Page three

Data sheet PM 01.10

Flush(Clamp)

Flush(3 hole)

Substitute .22K Substitute .23K

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 5

Page 6: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

The robust WIKA Type 213.53 pressure gauges have a stainless steel case and liquid filling.

They are intended for adverse service conditions where pulsation or vibration exists. They are

also suitable for gaseous or liquid media that will not obstruct the pressure system or

attack copper alloy parts.

• Copper alloy wetted parts

• Stainless steel case

• Glycerine filled

Standard features

Size: 63mm, 100mm

Wetted parts: Copper alloy

Case: Stainless steel

Bezel ring: Polished stainless steel

Window: Clear plastic

Dial: White plastic (63mm),

White aluminium (100mm)

Pointer: Black plastic (63mm),

Black aluminium (100mm)

Filling: Glycerine

Accuracy: ±1.6% of span 63mm,

±1.0% of span 100mm (EN 837)

Maximum process

temperature: 60ºC

Type 213.53

Page four

Substitute .11 Substitute .32Substitute .11 Substitute .22

Substitute .33

or

Data sheet PM 02.12

Model 213.53Nominal size 63mm 100mm

Design

Mounting Direct Direct Flush Direct Directbottom rear (Clamp) bottom rear

Accuracy ±1.6% of full scale deflection ±1.0% of full scale deflection

Connection 1/4" BSP taper 3/8" BSP taperScale range Dual scale kPa/psi Single scale kPa-100/0 kPa 530.9312604.10 530.9312905.23 500.9683325.10 500.9683357.30-100/60 kPa 530.9312612.10 530.9312914.23 500.9683327.10 500.9683358.30-100/150 kPa 530.9312620.10 530.9312922.23 500.9683328.10 500.9683359.30-100/300 kPa 530.9312638.10 530.9312930.23 500.9683329.10 500.9683360.30-100/500 kPa 530.9312646.10 530.9312948.23 500.9683330.10 500.9683361.30-100/900 kPa 530.9312655.10 530.9312956.23 500.9683331.10 500.9683362.30-100/1500 kPa 530.9312663.10 530.9312965.23 500.9683332.10 500.9683363.300/60 kPa 530.9312671.10 530.9312973.23 500.9683334.10 500.9683365.300/100 kPa 530.9312689.10 530.9312981.23 500.9683336.10 500.9683366.300/160 kPa 530.9312697.10 530.9312999.23 500.9683337.10 500.9683367.300/250 kPa 530.9312701.10 530.9313006.23 500.9683338.10 500.9683368.300/400 kPa 530.9312719.10 530.9313015.23 500.9683339.10 500.9683370.300/600 kPa 530.9312727.10 530.9313023.23 500.9683340.10 500.9683371.300/800 kPa 530.9312735.10 530.9313031.23 500.9683341.10 500.9683372.300/1000 kPa 530.9312744.10 530.9313049.23 500.9683342.10 500.9683373.300/1600 kPa 530.9312752.10 530.9313057.23 500.9683344.10 500.9683374.300/2500 kPa 530.8349660.10 530.9313065.23 500.9683345.10 500.9683375.300/4000 kPa 530.9311292.10 530.9313074.23 500.9683346.10 500.9683376.300/6000 kPa 530.9312760.10 530.9313082.23 500.9683347.10 500.9683378.300/8000 kPa 530.9312778.10 530.9313090.23 500.9683348.10 500.9683379.300/10x1000 kPa 530.9312786.10 530.9313104.23 500.9683349.10 500.9683380.300/16x1000 kPa 530.9312795.10 530.9313112.23 500.9683350.10 500.9683381.300/25x1000 kPa 530.9312808.10 530.9313120.23 500.9683352.10 500.9683382.300/40x1000 kPa 530.9312816.10 530.9313138.23 500.9683353.10 500.9683383.300/60x1000 kPa 530.9312825.10 530.9313146.23 500.9683354.10 500.9683384.300/80x1000 kPa - - 500.9683355.10 500.9683386.300/100x1000 kPa 530.9312833.10 530.9313155.23 500.9683356.10 500.9683387.30

Model 213.53.063Mounting Direct Direct Flush

bottom rear (Clamp)Connection G1/4 B (1/4" BSP parallel)Scale range Dual scale bar/psi-1/0 bar/ " Hg 509.9022199.10 509.9022200.200/1 bar/psi 509.9022156.10 509.9022127.200/1.6 bar/psi 509.9024958.10 509.9022164.200/2.5 bar/psi 509.9327660.10 509.9027452.200/4 bar/psi 509.9605015.10 509.9023476.200/6 bar/psi 509.9351154.10 509.9605075.200/10 bar/psi 509.9315832.10 509.8347670.200/16 bar/psi 509.9307758.10 509.9605083.200/25 bar/psi 509.9351162.10 509.9383586.200/40 bar/psi 509.9350955.10 509.9023477.200/60 bar/psi 509.9351170.10 509.9359775.200/100 bar/psi 509.9351145.10 509.9392064.200/160 bar/psi 509.9341948.10 509.9380546.200/250 bar/psi 509.8309515.10 509.9625661.200/400 bar/psi 509.8306370.10 509.9306094.200/600 bar/psi 509.9367009.10 509.9023471.20

Surface Flush (3 hole)

Flush (Clamp)

Substitute .23

Flush (Clamp)

Flush (3 hole)Surface

Hyd

raul

ic G

auge

s

or

9197 WIKA 20PP changes_2007 12/2/08 5:09 PM Page 6

Page 7: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Designed for industrial service, WIKA Type 212.20 gauges feature a

stainless steel case, copper alloy wetted parts and industrial grade Swiss

movement. Available in 100 and 160mm dial sizes, the gauges offer

repeatable accuracy and long service life.

Standard features

Size: 100mm, 160mm

Wetted parts: Copper alloy

Case: Stainless steel

Bezel ring: Stainless steel, bayonet

Window: Instrument glass

Dial: White aluminium

Pointer: Black aluminium

Accuracy: ±1.0% of span (EN 837)

Maximum process

temperature: 60ºC

• Copper alloy wetted parts

• Stainless steel case

• Industrial grade movement

• Other design options are available

Type 212.20

Flush (3 hole)

Flush (Clamp) Flush (Clamp)

Flush (3 hole)

Substitute .11 Substitute .32 Substitute .11 Substitute .32

Substitute .33 Substitute .33

Surface Surface

Model 212.20Nominal size 100mm 160mm

Design

Mounting Direct Direct Direct Directbottom rear bottom rear

Connection 3/8" BSP taperRange-100/0 kPa 500.9681947.10 500.9681983.30 501.9683216.10 501.9683052.30-100/60 kPa 500.9681948.10 500.9681984.30 501.9683217.10 501.9683053.30-100/150 kPa 500.9681949.10 500.9681985.30 501.9683218.10 501.9683054.30-100/300 kPa 500.9681950.10 500.9681987.30 501.9683219.10 501.9683055.30-100/500 kPa 500.9681951.10 500.9681988.30 501.9683220.10 501.9683056.30-100/900 kPa 500.9681953.10 500.9681989.30 501.9683221.10 501.9683057.30-100/1500 kPa 500.9681954.10 500.9681990.30 501.9683222.10 501.9683058.300/60 kPa 500.9681956.10 500.9681992.30 501.9683224.10 501.9683061.300/100 kPa 500.9681957.10 500.9681993.30 501.9683225.10 501.9683062.300/160 kPa 500.9681958.10 500.9681994.30 501.9683226.10 501.9683063.300/250 kPa 500.9681959.10 500.9682992.30 501.9683227.10 501.9683064.300/400 kPa 500.9681961.10 500.9682993.30 501.9683228.10 501.9683065.300/600 kPa 500.9681962.10 500.9682994.30 501.9683230.10 501.9683066.300/800 kPa 500.9681963.10 500.968299530 501.9683231.10 501.9683068.300/1000 kPa 500.9681964.10 500.9682996.30 501.9683232.10 501.9683069.300/1600 kPa 500.9681965.10 500.9682895.30 501.9683233.10 501.9683070.300/2500 kPa 500.9681966.10 500.9682896.30 501.9683234.10 501.9683071.300/4000 kPa 500.9681967.10 500.9682897.30 501.9683235.10 501.9683072.300/6000 kPa 500.9681968.10 500.9682898.30 501.9683236.10 501.9683073.300/8000 kPa 500.9681969.10 500.9682899.30 501.9683238.10 501.9683074.300/10x1000 kPa 500.9681970.10 500.9682900.30 501.9683239.10 501.9683076.300/16x1000 kPa 500.9681971.10 500.9682901.30 501.9683240.10 501.9683077.300/25x1000 kPa 500.9681972.10 500.9682902.30 501.9683241.10 501.9683078.300/40x1000 kPa 500.9681973.10 500.968290330 501.9683242.10 501.9683079.300/60x1000 kPa 500.9681974.10 500.9682904.30 501.9683243.10 501.9683080.300/80x1000 kPa 500.9681975.10 500.9682905.30 501.9683244.10 501.9683081.300/100x1000 kPa 500.9681976.10 500.9682906.30 501.9683246.10 501.9683082.3020/100 kPa 500.9681955.10 500.9681991.30 501.9683223.10 501.9683060.300/100% Linear

Page five

GA

UG

ES

ind

ustria

l

Data sheet PM 02.01

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 7

Page 8: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

WIKA Type 232.50 gauges feature 316 stainless steel wetted parts, a 304 stainless steel

case and bayonet ring, a laminated safety glass window and can be liquid filled in the field.

The stainless steel wetted parts and case construction ensure long service life in harsh,

demanding applications. WIKA stainless steel gauges are ideal for process, chemical and

petrochemical applications; oil exploration and production; power generation; pollution

control equipment; and, any other application that requires quality, long-lasting pressure

measurement instrumentation.

• All stainless steel construction

• Field liquid fillable

• ±1.0% accuracy

• Other design options are available

Standard features

Size: 63mm, 100mm, 160mm

Wetted parts: 316 stainless steel

Case: 304 stainless steel with

blow-out disc

Bezel ring: 304 stainless steel bayonet

Window: Laminated safety glass

Dial: White aluminium

Pointer: Black aluminium

Accuracy: ±1.0% of span (EN 837)

Maximum process temperature:

100ºC (233.50), 200ºC (232.50)

Model 232.50 and 233.50Nominal size 100mm 160mm

Design

Mounting Direct Direct Direct Directbottom rear bottom rear

Connection 1/2" NPTRange-100/0 kPa 502.9682496.10 502.9681996.30 503.9682198.10 503.9683011.30-100/60 kPa 502.9682497.10 502.9681997.30 503.9682199.10 503.9683012.30-100/150 kPa 502.9682498.10 502.9681998.30 503.9682200.10 503.9683013.30-100/300 kPa 502.9682499.10 502.9681999.30 503.9682201.10 503.9683014.30-100/500 kPa 502.9682500.10 502.9682000.30 503.9682202.10 503.9683015.30-100/900 kPa 502.9682501.10 502.9682001.30 503.9682203.10 503.9683017.30-100/1500 kPa 502.9682502.10 502.9682096.30 503.9682204.10 503.9683018.300/60 kPa 502.9682504.10 502.9682098.30 503.9682289.10 503.9683020.300/100 kPa 502.9682506.10 502.9682099.30 503.9682291.10 503.9683021.300/160 kPa 502.9682507.10 502.9682100.30 503.9682292.10 503.9683022.300/250 kPa 502.9682593.10 502.9682101.30 503.9682293.10 503.9683023.300/400 kPa 502.9682594.10 502.9682102.30 503.9682294.10 503.9683024.300/600 kPa 502.9682595.10 502.9682103.30 503.9682295.10 503.9683026.300/800 kPa 502.9682596.10 502.9682104.30 503.9682296.10 503.9683027.300/1000 kPa 502.9682597.10 502.9682105.30 503.9682297.10 503.9683028.300/1600 kPa 502.9682598.10 502.9682106.30 503.9682298.10 503.9683029.300/2500 kPa 502.9682599.10 502.9682107.30 503.9682299.10 503.9683030.300/4000 kPa 502.9682600.10 502.9682108.30 503.9682300.10 503.9683031.300/6000 kPa 502.9682601.10 502.9682186.30 503.9682301.10 503.9683032.300/8000 kPa 502.9682602.10 502.9682187.30 503.9682302.10 503.9683034.300/10x1000 kPa 502.9682603.10 502.9682188.30 503.9682303.10 503.9683035.300/16x1000 kPa 502.9682604.10 502.9682189.30 503.9682313.10 503.9683036.300/25x1000 kPa 502.9682700.10 502.9682190.30 503.9682314.10 503.9683037.300/40x1000 kPa 502.9682701.10 502.9682191.30 503.9682315.10 503.9683038.300/60x1000 kPa 502.9682702.10 502.9682192.30 503.9682316.10 503.9683039.300/80x1000 kPa 502.9682798.10 502.9682193.30 503.9682317.10 503.9683040.300/100x1000 kPa 502.9682799.10 502.9682194.30 503.9682318.10 503.9683042.3020/100 kPa 502.9682503.10 502.9682097.30 503.9682205.10 503.9683019.300/100% Linear

Type 232.50 Dry case / 233.50 Liquid filled

Page six

Data sheet PM 02.02

Flush (Clamp)

Substitute .33 Substitute .33

Liquid f i l led substitute 505 Liquid f i l led substitute 506

Flush (Clamp)

Surface Flush (3 hole)

Substitute .11 Substitute .32 Substitute .11 Substitute .32

Surface Flush (3 hole)

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 8

Page 9: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Liquid f i l led substitute 505

WIKA Type 232.30 stainless steel gauges offer the same advantages as

other WIKA stainless steel gauges, but also feature a solid-front / blow-

out back safety case.

WIKA stainless steel gauges are ideal for process, chemical and

petrochemical applications; oil exploration and production; power

generation; pollution control equipment; and any other application that

requires quality, long-lasting pressure measurement instrumentation.

• All stainless steel construction

• Field liquid fillable

• Solid-front safety case design

• Other design options are available

Standard features

Size: 63mm, 100mm

Wetted parts: 316 stainless steel

Case: 304 stainless steel (63 mm);

316 stainless steel (100 mm); both with

blow-out back

Bezel ring: 304 stainless steel bayonet (63 mm)

316 stainless steel bayonet (100 mm)

Window: Laminated safety glass

Dial: White aluminium

Pointer: Black aluminium

Accuracy: ±1.6% of span 63mm,

±1.0% of span 100mm (EN 837)

Maximum process temperature:

100ºC (233.30), 200ºC (232.30)

Model 232.30 and 233.30Nominal size 63mm 100mm

Design

Mounting Direct Directbottom bottom

Connection 1/4"NPT 1/2"NPT

Range-100/0 kPa 530.7977353.10 530.7051752.10-100/60 kPa 530.7977361.10 530.7977612.10-100/150 kPa 530.7977370.10 530.7977621.10-100/300 kPa 530.7977388.10 530.7051787.10-100/500 kPa 530.7977396.10 530.9166452.10-100/900 kPa 530.7977400.10 530.7977639.10-100/1500 kPa 530.7977418.10 530.7977647.100/60 kPa - 530.7977655.100/100 kPa 530.9688656.10 530.7683231.100/160 kPa 530.9685942.10 530.7977663.100/250 kPa 530.7170646.10 530.7683249.100/400 kPa 530.7062231.10 530.7051817.100/600 kPa 530.7198991.10 530.7683266.100/800 kPa 530.7731095.10 530.7386380.100/1000 kPa 530.8379254.10 530.7683274.100/1600 kPa 530.7731079.10 530.7683290.100/2500 kPa 530.7731087.10 530.7051850.100/4000 kPa 530.9688657.10 530.7245943.100/6000 kPa 530.7977426.10 530.7683312.100/8000 kPa 530.7977434.10 530.7051922.100/10x1000 kPa 530.7977442.10 530.7051931.100/16x1000 kPa 530.7977451.10 530.7051949.100/25x1000 kPa 530.8656568.10 530.7051957.100/40x1000 kPa 530.7977469.10 530.7223588.100/60x1000 kPa 530.7977477.10 530.7977671.100/80x1000 kPa 530.7977485.10 530.7977681.100/100x1000 kPa 530.7977493.10 530.7977699.1020/100 kPa 530.7977507.10 530.7977701.100/100% Linear

Type 232.30 Dry case / 233.30 Liquid filled

Page seven

Data sheet PM 02.04

Surface Substitute .11

GA

UG

ES

pro

ce

ss

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 9

Page 10: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Model 732.14Nominal sizes: 100 and 160mm

Housing: Stainless steel with

laminated safety glass window

Wetted parts: Stainless steel

Accuracy: ±1.6% of span

(EN 837)

Weather protection: IP 54

Ranges: 0…6 kPa to 0…4,000

kPa (static pressures up to

40,000 kPa)

Model 732.51Nominal sizes: 100 and 160mm

Housing: Stainless steel, with

blow-out disc and laminated

safety glass window

Wetted parts: Stainless steel

Accuracy: ±1.6% of span (EN 837)

Weather protection: IP 54

Ranges: 0…1.6 kPa to 0…2,500

kPa (static pressures up to

4,000 kPa)

DELTA-plusModel 702.01.100

DELTA-switchModel 851.02.100

DELTA-transModel 891.34.2189

DELTA-combModel 702.02.100

These models are suitable for monitoring differential

pressures in filter plants, pipelines systems, valves and

pumps in the gas, water and air supply markets.

Up to two alarm contacts can be added to either model.

Differential pressure gauges

Page eight

Main applications

• Potable and service water

treatment plants

• Heating, ventilation and

air-conditioning

• Dedusting equipment

• Technical building

equipment

• Pump monitoring and control

• Filter plants

Specifications

• Solid case construction

• Differential measuring

ranges: 0…25 kPa to

0…2,500 kPa

• Static pressure: 2,500 kPa

• Overload: 2,500 kPa (either side)

• Integrated static pressure

indicator: DELTA-plus and

DELTA-comb

WIKA offers a wide range of differential pressure gauges suitable for demanding applications in the HVAC and process markets. These gauges

feature differential measuring ranges from 0.25 kPa, static pressures up to 40,000 kPa and wetted parts materials that range from copper to

stainless steel.

WIKA has extended its wide variety of differential pressure gauges

by developing a new range of DELTA products - DELTA-plus,

DELTA-comb, DELTA-switch and DELTA-trans.

Each instrument features innovative design and an easy-to-read

differential pressure display. The rigid and compact design makes

the gauges ideal for tough industrial operating environments. The

four gauges have identical exteriors and geometrical features and

use the same diaphragm compression spring measuring system.

Data sheet PM 07.05

Data sheet PM 07.13

Data sheet PM 07.14

Model 700.02Model 700.01

Data sheet PM 07.15 Data sheet PM 07.16 Data sheet PM 07.17 Data sheet PM 07.18

Indicator Indicator and Switch Switch Indicator and Transmitter

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 10

Page 11: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Diaphragm gauges (Schäffer type) are ideal for applications that involve viscous and crystalising media in harsh environments such as pulp and

paper processing, chemical, petrochemical, and in water and sewerage treatment plants. Over pressure protection is a standard feature of these

diaphragm gauges. The level of over pressure protection varies from 3, 5 or 10 times indicated full-scale value.

Model 422.12

Nominal sizes: 100 and 160mm

Housing: Cast iron

Diaphragm: Stainless steel

Process housing: Black carbon steel

Accuracy: ±1.6% of span (EN 837)

Ranges: Flange Ø160mm 0…1.6 kPa to 0…25 kPa

Flange Ø100mm 0…40 kPa to 0…4,000 kPa

Process connection: All standard thread or

flange sizes are available

Liquid filling (if required): Glycerine (Model 423.12)

Moulded case solid-front safety designSpecifically designed for the chemical and petroleum processing industries, WIKA process gauges

have the construction, materials and engineering required for even the toughest of conditions.

These gauges are engineered to deliver years of accurate service and will withstand vibration,

corrosive media and environments and a wide range of temperatures.

• Solid-front / blow-out back

• Field liquid fillable

• Adjustable pointer

• 4 1/2" and 6"

Oxygen gauges solid-front safety case designSpecifically designed and manufactured in accordance with strict standards, WIKA oxygen and gaspattern gauges offer repeatable accuracy and long service life. The gauges are manufactured andmaintained in a degreased state to ensure that no oil comes in contact with the connection or internalsof the gauge. The gauge socket is fitted with a restrictor to limit the rate of pressurisation.

Size: 100mm and 160mmCase: 304 stainless steel with integral solid-front safety baffleBezel: 304 stainless steel bayonetWetted parts: In accordance with specification including Monel or 316 stainless steelWindow: Safety glassDial: White aluminiumPointer: Black aluminiumAccuracy: ±1.0% of span (AS 1349-1986)

Special application gauges

Page nine

Data sheet PM 02.10

Type 232.34 (Dry case)233.34 (Liquid filled)

Model 632.50Nominal sizes: 100 and 160mmHousing: Stainless steel with safety glass window and bayonet bezelWetted parts: Stainless steelAccuracy: ±1.6% of span (EN 837) Ranges: 0…1.6 kPa to 0…60 kPa (Ø100mm)

0…0.25 kPa to 0…60 kPa (Ø160mm)Zero adjustment: Externally through window

Model 432.50

Nominal sizes: 100 and 160mm

Housing: Stainless steel with rear blow-out disc

Wetted parts: Stainless steel, other options available,

(PTFE, Hastelloy, etc.)

Accuracy: ±1.6% of span (EN 837)

Ranges: Flange Ø160mm 0…1.6 kPa to 0…25 kPa

Flange Ø100mm 0…40 kPa to 0…4,000 kPa

Process connection: All standard thread or flange sizes

are available

Liquid filling (if required): Glycerine (Model 433.50)

Other versions available on application

Capsule gauges are extremely sensitive and highly accurate. The capsules are designed to measure pressure and vacuum of gaseousmedia from as low as 0.25 kPa. An adjustment screw is located on the dial to re-zero the pointer if necessary.

Model 611.10 and 612.20Nominal sizes: Model 611.10: 63mm, Model 612.20: 100 and 160mmCase: Model 611.10: Black steel with snap fit window

Model 612.20: Stainless steel with glass window and bayonet bezel

Wetted parts: Copper alloyAccuracy: ±1.6% of span (EN 837)Ranges: 0…2.5 kPa to 0…60 kPa (Model 611.10 and Model 612.20 Ø100mm)

0…0.6 kPa to 0…60 kPa (Model 612.20 Ø160mm)Zero adjustment: Externally through window

Data sheet PM 06.01/.02/.03

GA

UG

ES

spe

cia

lity

Data sheet PM 04.02

Data sheet PM 04.03

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 11

Page 12: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

The WIKA diaphragm seal system enables pressure gauges, pressure switches, pressure

transducers and transmitters of varying designs to be adapted for the most adverse

applications. The diaphragm seal is intended to separate the pressure instrument from the

pressure medium, whilst allowing pressure variations to be precisely sensed by the instrument.

The pressure applied on the diaphragm seal is transmitted to the pressure-sensing element by

means of a suitable liquid. The seal body and diaphragm are generally made of stainless steel.

A wide selection of special materials is also available to handle almost any exotic process fluid.

WIKA diaphragm seals are also ideal for hygienic applications such as in the food industry. The

seals are available in several designs and materials to ensure complete compatibility with the

process application.

Model 990.10/12 Standard Series

Diaphragm Seal

Intended service: General process

Wetted parts: 316 stainless steel or

Monel, PTFE, Hastelloy C276, Tantalum

Pressure rating: 25,000 kPa

Connection: Thread or flange

Model 990.36 High Pressure Flush

Diaphragm Seal

Intended service: High pressure or

applications where the diaphragm

must be close to the process

Wetted parts: 316 stainless steel

Pressure rating: 60,000 kPa

Connection: 1/2"…2" BSP

Model 990.40/41 Low Pressure

Diaphragm Seal

Intended service: Low range

pressure gauges, differential pressure

gauges or transmitters

Wetted parts: 316 stainless steel

Pressure rating: 4,000 kPa

Connection: Thread or flange

Model 990.34 Welded Body

Diaphragm Seal

Intended service: General process

Wetted parts: 316 stainless steel

Pressure rating: 10,000…100,000 kPa

Connection: 1/2" BSP/NPT male/female

Data sheet DS 99.01Data sheet DS 99.03

Data sheet DS 99.04

Data sheet CS 99.03

Page ten

Diaphragm seals

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 12

Page 13: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

diap

hrag

mData sheet DS 99.40/.41

Model 990.21/22 Hygienic

Diaphragm Seal

Intended service: Food, biochemical

and pharmaceutical

Wetted parts: 316L stainless steel

Pressure rating: 4,000 kPa

Connection: 3/4"…3" APV-RJT

(BSM), Triclamp

Data sheet DS 98.52

Model 981.10/27 Inline Flange

Diaphragm Seal

Intended service: Applications where

measuring points without dead space

is required

Wetted parts: 316 stainless steel, or

Monel, Hastelloy C276, Tantalum

Pressure rating: Class 150#…2500# ANSI

Connection: ANSI 1"…6"

Also available with integrated RTD or

thermocouple

Model 990.27 Flange

Diaphragm Seal

Intended service: Process industry

Wetted parts: 316 stainless steel, or

Monel, PTFE, PFA, Hastelloy C276,

Tantalum, Titanium, Ceramic

Pressure rating: Class 150#…Class

2500# ANSI

Connection: ANSI 1"…5"

Model 990.28 Cell Type (Sandwich)

Diaphragm Seal

Intended service: Process industry

Wetted parts: 316 stainless steel, or

Monel, PTFE, PFA, Hastelloy C276,

Tantalum, Titanium, Ceramic

Pressure rating: Class 150#…Class

2500# ANSI

Connection: ANSI 2"…5"

Data sheet DS 99.28Data sheet CS 98.03/.05 Data sheet DS 99.27

Model 981.22 Inline Hygienic

Diaphragm Seal

Intended service: Food, biochemical

and pharmaceutical

Wetted parts: 316L stainless steel

Pressure rating: 4,000 kPa

Connection: 3/4"…4" APV-RJT

(BSM), Triclamp

Also available with integrated RTD or

thermocouple

Page eleven

Diaphragm seals

Model 990.29 Extended Nozzle Flange

Diaphragm Seal

Intended service: Lagged pipes or vessels in

the process industry

Wetted parts: 316 stainless steel, or Monel,

PFA, Hastelloy C276, Tantalum, Titanium

Pressure rating: Class 150/300# ANSI

Connection: ANSI 2"…5"

Extension: 50, 100, 150, 200mm

Data sheet DS 99.29

Data sheet CS 99.10

Model 990.30 Homogeniser

Diaphragm Seal

Intended service: High pressure gauges

or transmitters

Wetted parts: 316 stainless steel

Pressure rating: 60,000 kPa

Connection: Special flange

Model 981.31 Concrete/Slurry Seals

Seals for concrete/slurry are available in

threaded or inline configurations.

SE

AL

S

9197 WIKA 20PP changes_2007 12/2/08 5:10 PM Page 13

Page 14: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

The UniTrans pressure transmitter is designed for a variety of pressure measurement

applications. Its 20:1 turndown capability provides flexibility when wide changes in

measuring ranges are encountered. It is also available with PROFIBUS PA and HART®

Protocol.

• 0.15% accuracy

• User adjustable turndown of up to 20:1

• All stainless steel wetted parts

• 4-20mA 2-wire output signal

• Large, easy-to-read LCD includes bar graph and trend display is optional

Page twelve

WIKA piezoresistive and thin film pressure transmitters

are precision engineered to fit the majority of industrial

pressure measurement applications. Each unit undergoes

quality control testing and calibration to achieve high

levels of accuracy and repeatability. State of the art

surface mount technology ensures that the unit is

protected against vibration, shock and humidity. Each

unit is temperature compensated to ensure accuracy

and long-term stability under severe ambient temperature

conditions.

The stainless steel casings offer IP65 ingress protection

as standard, with IP67, IP68 and IP69 as options on

some models. Applications for the transmitters cover

water and wastewater, pulp and paper, marine, tank

level, test equipment and many other process control

operations. Flush diaphragm models are available to

measure highly viscous fluids or media that contains

solids. Ranges from 0…0.1 bar to 0…4,000 bar are

covered across the WIKA range. Models for special

applications, including intrinsically safe and oxygen

service, are also available.

Data sheet PE 86.01/.02

Model UT-11 (flush diaphragm) and UniTrans Model UT-10 (1/2" NPT male)

S-10 S-11 S-11 withcooling element

Model S-10 S-11 IS-10 IS-11Design Standard Flush diaphragm Standard Flush diaphragm

Ex-version

Certificate No. ANZEx 04.3007XEx. ia. I/IIC T6

Data sheet PE 81.01 PE 81.22Accuracy (+ % of FSV) 0.25% (BFSL)Degree of protection IP65 Power supply DC 10...30VSignal output 4...20 mAWire system 2-wireElectrical connection 4-pin L-plug per DIN 43 650

1) 1" BSP parallel with 1) 1" BSP parallel with“O” ring “O” ring

Pressure connection 1/2" BSP parallel 1/2" BSP parallel2) 1/2" BSP parallel 2) 1/2" BSP parallel

“O” ring “O” ringScale range

531.9013466 531.9810714 1) 531.8372826 531.8373006 1)

531.9810315 531.9810722 1) 531.8372836 531.8373016 1)

531.9810323 531.9810730 1) 531.8372846 531.8373026 1)

531.9810331 531.9810757 1) 531.8372856 531.8373036 1)

531.9083499 531.9083537 1) 531.8372866 531.8373046 1)

531.9083502 531.9083545 1) 531.8372876 531.8373056 1)

531.9021329 531.9021264 1) 531.8372886 531.8373066 1)

531.9013474 531.9021272 1) 531.8372906 531.8373076 1)

531.9013482 531.9021280 1) 531.8372916 531.8373096 1)

531.9013490 531.9021299 1) 531.8372936 531.8373106 1)

531.9013504 531.9021302 1) 531.8372946 531.8373126 1)

531.9013512 531.9021310 2) 531.8372956 531.8373136 2)

531.9013520 531.9021213 2) 531.8372966 531.8373146 2)

531.9013539 531.9021221 2) 531.8372976 531.8373156 2)

531.9013547 531.9021230 2) 531.8372986 531.8373166 2)

531.9013555 531.9021248 2) 531.8372996 531.8373176 2)

531.9073922 531.9023518 2) 531.8373186 531.8373296 2)

531.9073930 531.9023520 2) 531.8373196 531.8373306 2)

531.9073949 531.9023534 2) 531.8373206 531.8373316 2)

531.9073957 531.9023542 2) 531.8373216 531.8373326 2)

531.9073965 531.9023550 2) 531.8373226 531.8373336 2)

531.9073973 531.9023569 2) 531.8373236 531.8373346 2)

531.9073981 531.9023577 2) 531.8373246 531.8373356 2)

531.9073990 531.9023585 2) 531.8373276 531.8373366 2)

531.9074015 - 531.8373286 -

-1/0 bar-0.6/0 bar-0.4/0 bar-0.25/0 bar0/0.1 bar0/0.16 bar0/0.25 bar0/0.4 bar0/0.6 bar0/1 bar0/1.6 bar0/2.5 bar0/4 bar0/6 bar0/10 bar0/16 bar0/25 bar0/40 bar0/60 bar0/100 bar0/160 bar0/250 bar0/400 bar0/600 bar0/1000 bar

Pressure transmitters

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 14

Page 15: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Digital Panel Meters

WIKA programmable process

meters are ideal for use with Tronic

Line pressure transmitters when a

programmable display or controller is required. The indicators are

user programmable with universal input 4-20 mA, 0-20 mA, 0-5 V

0-10 V, and DI-35-D features Dual inputs with four basic arithmetic

operations (+ - x /).

Model Accuracy Display Nominal size

DI-15 0.5± 1-digit LED 4-digit 48 X 24mm

A-RB-1 0.05± 2-digit LED 31/2-digit 96 X 48mm

DI-35 0.05± 1-digit LED 5-digit 96 X 48mm

Output signal and interface include 4-20 mA, 0-20 mA, 0-10 V,

0-5 V, RS-232 and RS-485. Features include minimum and

maximum memory, adjustable alarm contacts and hysteresis and

in-built transmitter power supply.

Mobile Hydraulics Model MH-1

Its extremely high resistance to shock, vibration and

pressure peaks, combined with degrees of protection of

better than IP 68, make this instrument particularly suitable

for the rough operating conditions of mobile hydraulics.

Pressure ranges from 0…60 bar to 0…600 bar are

available to meet all standard mobile hydraulic applications.

The sensor is recessed into the pressure connection,

offering additional protection against oil loss should the

sensor be destroyed.

Data sheet PE 81.21

Submersible Model LS-10/LH-10

WIKA submersible liquid level transmitters are

engineered for a wide variety of industrial and

municipal liquid level applications. The compact,

rugged, submersible pressure transmitters’

applications include water and wastewater

treatment, well depth measurement and

offshore water depth measurement. Cable

lengths up to 300 metres and lightning

protection are just two of the options available

for this model.

Data sheet PE 81.19

Fieldcase Model F-20/F-21

These transmitters are designed for extremely harsh

industrial pressure measurement applications. The

compact design features an integral IP 67 junction box

and protection against electromagnetic interference. The

304 stainless steel case and 316 stainless steel wetted

parts make it particularly suited to outdoor applications in

offshore, chemical and petroleum refineries where reliable

pressure measurement is critical.

Page thirteen

Precision Model P-10/P-11

WIKA precision transmitters are designed for

monitoring, testing and calibration applications

where accuracies of ≤0.1% of span are required.

The microprocessor based transmitter provides

excellent linearity and repeatability. Available

outputs include 0-20 mA 3-wire, 4-20 mA

2-wire, 0-5 V and 0-10 V 3-wire, RS-232 and

RS-422 for digital output to a computer.

Data sheet PE 81.60

Data sheet PE 81.32

Data sheet PE 81.09/.23

ECO Tronic Model ECO-1

ECO Tronic pressure transmitters and transducers

combine performance, reliability and value for a wide

variety of electronic pressure measurement applications.

They are available in ranges from 0…1 bar to 0…1,000

bar. The transmitter version provides 4-20 mA 2-wire

signal output. The transducer version supplies a 0-10

VDC 3-wire output signal. Both signals are fully

conditioned and provide an output that is both linear

and proportional to the applied pressure.

Data sheet PE 81.14/.18

The Next Generation A-10

With a stainless steel case and compact

design, WIKA OEM pressure transmitters

are specifically designed to meet price and

performance requirements of Original

Equipment Manufacturers (OEM). OEM

applications include hydraulics, HVAC

compressor control, machine tools and

robotics. They are also available in a

miniature design model, M-10.

Data sheet AC 80.01/.02/.03/.04/.05

Data sheet AC 80.07

Attachable Indicator Model A-AI-1

The loop powered attachable indicator

is designed for use with the 4-pin ‘L’

plug supplied with Tronic Line transmitters.

The indicator is user programmable for

a display range of -1,999 to +9,999.

The 10mm LCD display can be tilted for

improved viewing. The indicator meets

IP 65 weather protection and has an

excellent price performance ratio.optional

tron

iclin

ePressure transmitters

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 15

Page 16: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

DH-Budenberg Deadweight Primary

Standards & Differential Deadweight

Testers:

Models: Pneumatic 551, 552, 554, 556, 558

Hydraulic 580L, 580M, 580DX, 580HX,

580EHX, 283, 80, 80L.

• Ranges -100 kPa to 400,000 kPa

• Accuracy 0.008% to 0.015%

DH-Budenberg Reference &

Precision Calibration, Including:

Pneumatic Reference Standards 5200 series

& Hydraulic 5300 series, with ranges up to

500MPa.

Differential Pressure Balance 5500 series:

static pressure to 100 MPa & DP to 95 MPa

Digital Piston Gauges DPG10A (absolute) &

DPG10G (gauge) with ranges from -5 hPa

to 25 MPa.

• Accuracy 0.001% to 0.015%

DH- Budenberg Portable Calibrators

& Comparators:

Model: PPS42 portable calibrator in single or

dual range with ranges from vacuum to 70,000

kPa.

Desktop comparators P542 (pneumatic) &

H542 (hydraulic) with ranges from vacuum to

260,000 kPa.

• Accuracy 0.025%

Mensor Precision Pressure

Calibrator & Controller

CPC8000 series

Features:

• Pressure ranges to 160,000 kPa

• Control stability: 0.001% FS

• Accuracy: 0.004%

• Dual range version

• High Speed controlling & stability

Mensor Precision Pressure

Controller CPC6000 series:

Features:

• Dual range option with up to 4 sensors

• Touch Screen

• Pressure ranges:

0 to 2.5 kPa up to 10,000 kPa

• Control stability: up to 0.003% FS

• Accuracy: up to 0.005%

WIKA Precision Temperature

Calibrators Dry Block and Liquid Baths

Models:

• CTD9100 & CTD9300 dry well calibrators with

ranges from -30C to 165ºC & 40ºC to 650ºC

• CTB9210 Calibration Bath, range 40ºC to 250ºC

• CTB9220 Calibration Bath, range 40ºC to 250ºC

• CTB 9430 Calibration Bath, range -30ºC to

200ºC

• CTB9100 Micro Calibration Baths, ranges

from -30ºC to 165ºC & 40ºC to 225ºC

Page fourteen

Test and calibration equipment

Deadweight testers

• Range -100 kPa to 120,000 kPa

• Best uncertainty 0.006%

Gauges, transducers and

transmitters

• Range -100 kPa to 350,000 kPa

• Best uncertainty 0.006%

Liquid in glass and mechanical

thermometers, digital (RTD’s

and thermocouples)

• Range -75ºC to 500ºC

• Best uncertainty 0.01ºC

NATA Accreditation Laboratory 410

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 16

Page 17: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

WIKA CPH6000 Portable

Process Calibrator

Features:

• Easy change sensors

• Powers & reads test items

• Calibration & Pressure Switch

test function

• RS232 & USB interface

• Ranges: from 0-25 kPa up to

100,000 kPa

• Accuracy: 0.025%

Mensor Portable Pressure

Indicator Model 2300 series

Features:

• Dual Range Option

• Accuracy 0.015%

• Temperature compensation

• Absolute and Gauge versions

can be in the same instrument

WIKA Hand-Held Pressure

& Temperature Indicators

The CPH6200 pressure indicator &

logger features ranges from 0-10kPa up

to 100,000 kPa

The CTH6200 temperature indicator &

logger features a range of -50ºC up to

250ºC

Data sheet PE 84.20

Standard features

Size:160mm

Case: 304 stainless steel

Bezel ring: 304 stainless steel bayonet

Wetted parts: Copper alloy

Movement: Copper alloy and argentan

Window: Instrument glass

Dial: White aluminium with mirrored band

Pointer: Black aluminium, knife-edge

Accuracy: ±0.25% of span (AS1349-1986 clause 4.1.1)

NATA certificates can be supplied as an option

The range of

Wallace & Tiernan

analogue precision

gauges/portable

pneumatic calibrators

is also available.

Model 312.20Design

Scale range-100/0 kPa 519.9153834.11-100/150 kPa 519.9153835.11-100/300 kPa 519.9153836.110/100 kPa 519.9153838.110/160 kPa 519.9153839.110/250 kPa 519.9153841.110/400 kPa 519.9153842.110/600 kPa 519.9153843.110/1000 kPa 519.9153844.110/1600 kPa 519.9153846.110/2500 kPa 519.9153847.110/4000 kPa 519.7428678.110/6000 kPa 519.9153848.110/8000 kPa 519.9153849.110/10x1000 kPa 519.9153850.110/16x1000 kPa 519.9153851.110/25x1000 kPa 519.9153852.110/40x1000 kPa 519.7918896.110/60x1000 kPa 519.9153854.11

Page fifteen

ca

libra

tion

Portable calibration equipment

Test Gauges

The extremely sensitive and highly accurate. WIKA Type 312.20 Test Gauges are excellent for instrument shops, gauge

repair and calibration shops, testing laboratories and other applications that demand high precision and consistent

results. Type 312.20 Test Gauges feature knife-edge pointers and mirror bands on the dial to ensure precise readings

and to eliminate parallax error. Inside, a low-friction, wear resistant movement made of copper alloy and argentan

delivers a long service life and consistent

levels of accuracy.Data sheet PM 03.01

Data sheet PE 89.09

WIKA Hand Test Pump CPP-30

An easy to use pneumatic pressure hand-

pump, with extended pressure and vacuum

generation from -95 kPa to + 3500 kPa, with

large volume fine adjustment to ensure

precise setting over a wide range.

WIKA Hydraulic Test Pumps

WIKA CPP series of Hydraulic Spindle Pumps, with ranges

of: 0-100,000 kPa, 160 MPa, 500 MPa, & 700 MPa

The CPP series have been designed around a solid

platform and with the proven technology from the WIKA

CPB5000 pressure balance.

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 17

Page 18: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Model PS-20/PS-21

Sensing principle: Piezoresistive and thin film element

Pressure ranges: 0…0.25 bar to 0…1,000 bar

Overpressure safety: 2 bar to 1,500 bar

Pressure connection: 1/2" BSP (1/2" NPT option)

Wetted parts: 316 Stainless steel

Cable connection: Hirschmann Plug (L-plug) or fly lead

Adjustment accuracy of switching points:

≤0.5% of scale (BFSL)

Switch points: (max. 2) 0 – 100% of span

Switching hysteresis: 1 – 99% of span

Switch modes: PNP, NPN, PNP-PNP, NPN-NPN,

PNP-NPN, Potential Free

Unlike conventional switches, the electronic pressure switch is extremely accurate, resistant to shock and

vibration and offers unrivalled set point security. The latest technology, combined with the switch’s sturdy and

compact construction, ensures its reliability and long-term stability. Using the Windows-based WIKA Easy

Switch software, the switch is easily programmed to meet the needs of the customer.

Cella Explosion Proof and Intrinsically Safe Pressure Switches

Type: Pressure and Differential Pressure

Ranges: 0…10 mbar to 0…600 bar

Rating: EEx-d IIC T6, EEx-ia according to CENELEC

Options: Suitable for offshore applications (NACE)

Page sixteen

Data sheet: PE 81.28

FEMA Mechanical Pressure Switches

• Proven safety

• Solid aluminium die cast housing

• 1/2" BSP parallel connection

• Ex-versions available

Model Adjustment Switching Maximum Wetted

range differential pressure parts

DCM 025 0.04…0.25 bar 0.03 bar 6 bar Copper alloy

DCM 06 0.1…0.6 bar 0.04 bar 6 bar Copper alloy

DCM 1 0.2…1.6 bar 0.04 bar 6 bar Copper alloy

DCM 3 0.2…2.5 bar 0.1 bar 16 bar 1.4104 stainless steel

DCM 6 0.5…6 bar 0.15 bar 16 bar 1.4104 stainless steel

DCM 625 0.5…6 bar 0.25 bar 25 bar 1.4104 stainless steel

DCM 10 1…10 bar 0.3 bar 25 bar 1.4104 stainless steel

DCM 16 3…16 bar 0.5 bar 25 bar 1.4104 stainless steel

DCM 25 4…25 bar 1.0 bar 60 bar 1.4104 stainless steel

DCM 40 8…40 bar 1.3 bar 60 bar 1.4104 stainless steel

DCM 63 16…63 bar 2.0 bar 130 bar 1.4104 stainless steel

FEMA Mechanical Pressure Switches are potential free switches, with adjustable

microswitches that have switching capacity of 10A at 250VAC.

Pressure switches

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 18

Page 19: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Indicating Pressure Switches

Indicating Pressure Switches combine local pressure indication with alarm and

control capabilities into a single, economical and compact system. The WIKA

Indicating Pressure Switches are extremely reliable and have low hysteresis and

easy set point adjustment. They are ideally suited for alarm and control functions

on hydraulic, pneumatic and general industrial machinery and equipment as well

as process industry installations. They are available in dry and liquid filled

configurations.

Alarm contact types:

• Single, double and triple

• Front mounting magnetic contacts (Model 820)

• Built in magnetic contacts (Model 821)

• Built in inductive contacts (Model 831)

Contact setting: Contacts are set by means of a key from the front window

Contact actuation: The contacts are actuated when the instrument pointer

sweeps the contact indicator from either side

Square and rectangular cased

gauges for panel mounting

Model 214.11 (Bourdon Tube) and

614.11 (Capsule)

Nominal size: 48 x 24, 72 x 36, 72 x 72,

144 x 72, 96 x 96, 144 x 144mm

Housing: Galvanized steel

Wetted parts: Copper alloy

Accuracy: ±1.0/1.6% of full scale

Ranges: 0…0.25 kPa to 0…100,000 kPa

Accessories for pressure gauges

• Restrictor screws

• Drag or indicating pointers

• Special and customised dials

• Adjustable pointer

• Instrument tags

• Certificates of compliance

• NATA certification

• Thread adaptors in brass and stainless steel

• Pigtail and U-tube steam trap syphons in mild steel and

stainless steel

• Shut off cocks in brass up to 2,500 kPa

• Shut off needle valves in mild steel and stainless steel up

to 60,000 kPa

• Sealing washers in copper, steel, PTFE, stainless steel

and aluminium

• Overpressure limiting valves in brass and stainless steel

• Wall mounting brackets

• Pipe connectors

• Pipe weld-in nipples

• Snubbing valves

• Pressure equalising valves

• Cooling elements

• Rubber gauge protecting covers

• Sinter filters

• T-pieces

Page seventeen

Data sheet: PM 02.07/.08PM 06.05

Bottle and can testers(Carbonation testers)

Intended service: To test the CO2 content of

soft drinks in plastic bottles, aluminium cans or

soft drink post mix machines.

Pressure sensor: Transmitter S-10

Optional temperature sensor: Pt100 RTD

Display: Digital panel meters in field casing

accessories

Options and accessories

9197 WIKA 20PP changes_2007 12/2/08 5:11 PM Page 19

Page 20: 9197 WIKA 20PP changes 2007...WIKA is represented in 100 countries throughout the world and has more than 3000 employees located in over 20 countries. In Australia, WIKA’s worldwide

Pressure Units Cross Reference Chart

To use this chart:

1. Find the column with the units you want to convert from.2. Move down that column until you find the "1"

3. Staying with the same row, move horizontally to the columnwith the units you are converting to.

4. Multiply the number in that box by the amountyou are changing from to get the converted value.

Pressure andTemperature Measurement

psi atms. " H2O mm H2O cm H2O oz/in2 Kg/cm2 " Hg mm Hg cm Hg mbar bar Pa (Nm2) kPa MPa(Torr)

1 0.0681 27.71 703.8 70.38 16 0.0704 2.036 51.715 5.17 68.95 0.0689 6895 6.895 0.0069

14.7 1 407.2 10,343 1,304.3 235.1 1.033 29.92 760 76 1013 1.013 101,325 101.3 0.1013

0.0361 0.00246 1 25.4 2.54 0.5775 0.00254 0.0735 1.866 0.187 2.488 0.00249 248.8 0.249 0.00025

0.001421 0.000097 0.0394 1 0.1 0.0227 0.0001 0.00289 0.0735 0.00735 0.098 0.000098 9.8 0.0098 0.00001

0.01421 0.000967 0.3937 10 1 0.227 0.001 0.0289 0.735 0.0735 0.198 0.00098 98 0.098 0.0001

0.0625 0.00425 1.732 43.986 4.40 1 0.0044 0.1273 3.232 0.323 4.31 0.00431 431 0.431 0.00043

14.22 0.968 394.1 100,010 1,001 227.6 1 28.96 735.6 73.56 980.7 0.981 98,067 98.07 0.0981

0.4912 0.03342 13.61 345.7 34.57 7.858 0.0345 1 25.4 2.54 33.86 0.0339 3386 3.386 0.00339

0.01934 0.001316 0.536 13.61 1.361 0.310 0.00136 0.0394 1 0.1 1.333 0.001333 133.3 0.1333 0.000133

0.1934 0.01316 5.358 136.1 13.61 3.10 0.0136 0.394 10 1 13.33 0.01333 1333 1.333 0.00133

0.0145 0.000987 0.4012 10.21 1.021 0.2321 0.00102 0.0295 0.75 0.075 1 0.001 100 0.1 0.0001

14.504 0.987 401.9 10,210 1021 232.1 1.02 29.53 750 75 1000 1 100,000 100 0.1

0.000145 0.00001 0.00402 0.102 0.0102 0.00232 0.00001 0.000295 0.0075 0.00075 0.01 0.00001 1 0.001 0.000001

0.14504 0.00987 4.019 102.07 10.207 2.321 0.0102 0.295 7.5 0.75 10 0.01 1,000 1 0.001

145.04 9.869 4019 102,074 10,207 2321 10.2 295.3 7500 750 10,000 10 1,000,000 1,000 1

Part of your business

WIKA Austral ia Pty LtdABN 49 004 465 936

Rydalmere NSW 2116Tel 02 8845 5222Fax 02 9684 4767

Unit 3 , 24 Lakeside DriveBurwood East VIC 3151Tel 03 8847 2000Fax 03 9802 9559

Unit 3 , 435 Montague RoadWest End QLD 4101Tel 07 3255 3883Fax 07 3255 3816

Unit 4 , 158 Francisco StreetBelmont WA 6104Tel 08 9333 1500Fax 08 9479 5834

www.wika.com.au [email protected]

Speci f icat ions and d imensions g iven represent the state of engineer ing at

the t ime of pr int ing. Modi f icat ions may take p lace and mater ia ls speci f ied

may be replaced by others wi thout pr ior not ice

© WIKA 2013

Unit K, 10-16 South Street