91 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward EC...
Transcript of 91 General information AC centrifugal, backward AC centrifugal, forward EC centrifugal, backward EC...
90
91
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
AC centrifugal fans and blowers forward curved
AC centrifugal blowers, dual inlet Ø 097 - Ø 250 178
AC centrifugal blowers with plastic housing, dual inlet Ø 140 - Ø 160 158
AC centrifugal fans and blowers, single inlet Ø 085 - Ø 400 92
92
AC centrifugal fan and blowersingle inlet, Ø 085
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 085 M2E 042-CA
subject to alterations
20 40 60 80
0 10 20 30 40 50 [CFM]
[Pa]
40
80
120
160
0,2
0,4
0,6
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
2430
2590
n[rpm]
P1
[W]I
[A]
32
30
0.15
0.14
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 80 2350 32 0.15 1.0 /400 53 0 -25 to +601~ 230 60 95 2800 30 0.14 1.0 /400 57 0 -25 to +70
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
93
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Capacitor: FPU (P2) acc. to IEC 252
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R2E 085-AA01 -05
kg
0.7
Centrifugal blowerwith flange
G2E 085-AA01 -01
Ø30
M4±0,1
47
Ø67
2
±168
57±1
20
±0,
1Ø
17
±20300
6
Ø59
Ø85
42
-1
42
84
7666
56
71,5
80 300
34,5
4,5
58
Ø65
5,5
117,560,2
3
68
116,
5
54,5
3x12
0˚
M4
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
0.9
Mas
s of
ce
ntri
fuga
l blo
wer
Depth of screw
max. 4 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
94
AC centrifugal fan and blowersingle inlet, Ø 097
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 097 M2E 042-CA
subject to alterations
20 40 60 80 100
0 20 40 60 [CFM]
[Pa]
40
80
120
160
200
0,2
0,4
0,6
0,8
[in H
2O
]
[m3/h]
60 Hz50 Hz
1
2
A
Curves
2120
2335
n[rpm]
P1
[W]I
[A]
35
33
0.16
0.15
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 100 2050 35 0.16 1.5 /400 55 0 -25 to +401~ 230 60 110 2300 37 0.17 1.5 /400 58 0 -25 to +55
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
95
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Capacitor: FPU (P2) acc. to IEC 252
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R2E 097-AD01 -05
kg
0.6
Centrifugal blowerwithout flange
G2E 097-HD01 -02
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.1
Mas
s of
ce
ntri
fuga
l blo
wer
Ø32
M4
±0,147
Ø79
2
±141,5
55,9±1
20
±0,
1Ø
17
±20300
6
Ø59
Ø97
40
137
96
3x 120˚
3
56,5˚
75
75
24
18
3
53
1
1
46
Ø80
300
60
6
1
143
Depth of screw
max. 4 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
96
AC centrifugal fan and blowersingle inlet, Ø 108
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 108 M2E 052-BF
subject to alterations
40 80 120 160
0 20 40 60 80 100 [CFM]
[Pa]
80
160
240
320
0,4
0,8
1,2
[in H
2O
]
[m3/h]
60 Hz50 Hz
A
1
2
Curves
2070
2470
n[rpm]
P1
[W]I
[A]
34
31
0.16
0.15
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 160 1850 30 0.14 1.0 /400 56 0 -25 to +851~ 230 60 160 1850 35 0.16 1.0 /400 56 0 -25 to +80
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
97
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R2E 108-AG63 -05
kg
0.6
Centrifugal blowerwith flange
G2E 108-AG63 -01
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.3
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø84
±163
54±1
15
±20300
6
Ø72
Ø10
8
52
4
Ø87
-1
300
8
71
79
118
159
M4
115
97
76
50
82
83 66
168
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
98
AC centrifugal fan and blowersingle inlet, Ø 120
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 120 M2E 068-BF
subject to alterations
40 80 120 160 200 240
0 25 50 75 100 [CFM]125
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
A
1
2
Curves
2460
2665
n[rpm]
P1
[W]I
[A]
77
69
0.34
0.31
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 255 2350 80 0.35 2.0 /450 61 0 -25 to +551~ 230 60 265 2450 100 0.44 2.0 /450 62 0 -25 to +60
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
99
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal fan
R2E 120-AR77 -05
kg
1.2
Centrifugal blowerwith flange
G2E 120-AR77 -01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.8
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø96
2
±183
63±1
15
±0,
1Ø
27
±20450
6
Ø92
Ø12
0
62
4
Ø10
0-1
450
7
86
82
132
178
M4
115
100
76
50
98
83 68
184
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
100
AC centrifugal fans and blowerssingle inlet, Ø 120
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F", "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
Nominal data
Type Motor
*2E 120 M2E 052-BF
*2E 120 M2E 068-BF
subject to alterations
40 80 120 160 200 240
0 25 50 75 100 125 150 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
1
2
2
A
1
B
Curves
2200
2410
2335
2580
n[rpm]
P1
[W]I
[A]
54
51
80
72
0.24
0.23
0.36
0.32
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 190 2050 57 0.25 1.5 /400 63 0 -25 to +551~ 230 60 185 2000 66 0.29 1.5 /400 63 0 -25 to +55
1~ 230 50 275 2200 83 0.37 2.0 /450 64 0 -25 to +701~ 230 60 255 2050 100 0.45 2.0 /450 63 0 -25 to +60
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
101
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCCB
Centrifugal fan
R2E 120-BD76 -09
R2E 120-AR21 -05
Dimensions
kg
1.0
1.2
b c
42.0 48.0
62.0 85.0
Dimensions
A B C D F G I
— — — — 59.0 — 60.0
110.0 94.0 98.0 82.0 77.0 6.0 99.0
Centrifugal blowerwithout flange
G2E 120-TD76 -01
—
Centrifugal blowerwith flange
—
G2E 120-CR21 -01
6
85
450I
GØ
95
87
170,5
45˚4x90˚
3
101
180
DC
A
B
F
7167
110
Ø55
M4
±0,158
Ø96
2
±1c
63 ±1
15
±0,
1Ø
27
±20450
6
Ø92
Ø12
0
b
Terminal boxp. 562
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.3
1.9
Mas
s of
ce
ntri
fuga
l blo
wer
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
Depth of screw
max. 5 mmBrass lead tips
102
AC centrifugal fan and blowersingle inlet, Ø 133
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 133 M2E 068-BF
subject to alterations
40 80 120 160 200 240
0 25 50 75 100 125 150 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
1
2
A
Curves
2290
2530
n[rpm]
P1
[W]I
[A]
83
73
0.37
0.33
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 245 2150 88 0.39 2.0 /450 65 0 -25 to +601~ 230 60 235 2100 110 0.49 2.0 /450 65 0 -25 to +50
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
103
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R2E 133-AN77 -01
kg
1.3
Centrifugal blowerwith flange
G2E 133-DN77 -01
Terminal boxp. 562
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.9
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4
±0,158
Ø10
8
2
±168,5
63±1
15
±0,
1Ø
27
±20450
6
Ø92
Ø13
3
46
6 85
450
81
Ø11
2
87
170,5
45˚4x90˚
3
101
180
59
7167
140
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
104
AC centrifugal fan and blowersingle inlet, Ø 140
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 140 M2E 052-CA
subject to alterations
40 80 120 160 200 240
0 25 50 75 100 125 150 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
A
1
2
Curves
1460
1930
n[rpm]
P1
[W]I
[A]
62
56
0.29
0.26
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 240 1350 63 0.29 1.5 /400 55 0 -25 to +451~ 230 60 225 1300 70 0.31 1.5 /400 53 0 -25 to +35
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
105
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
Centrifugal fan
R2E 140-BI52 -05
kg
1.4
Centrifugal blowerwith flange
G2E 140-DI52 -01
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
1.9
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4
±0,158
Ø12
1.9
±145
58,8 ±1
20
±20450
6
Ø92
Ø14
0
37,4
6
85
45062
Ø12
5,5
95
216
45˚4x90˚
3
137,
6
242
62
7167
158
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
106
AC centrifugal fan and blowersingle inlet, Ø 140
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 140 M2E 068-BF
subject to alterations
80 160 240 320
0 40 80 120 160 200 [CFM]
[Pa]
80
160
240
320
0,4
0,8
1,2
[in H
2O
]
[m3/h]
60 Hz50 Hz
1
2
A
Curves
1700
2100
n[rpm]
P1
[W]I
[A]
98
89
0.43
0.40
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 370 1400 105 0.46 2.0 /450 59 0 -25 to +401~ 230 60 335 1500 115 0.51 2.0 /450 57 50 -25 to +45
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
107
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal fan
R2E 140-AE77 -05
kg
1.2
Centrifugal blowerwith flange
G2E 140-AE77 -01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
2.6
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø12
1
2
±172
63±1
15
±0,
1Ø
27
±20450
6
Ø92
Ø14
0
59
5
Ø11
8-1
450
6,3
107
103
158
227
M4
130
115
94
92
100
120
105
248
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
108
AC centrifugal fans and blowerssingle inlet, Ø 140
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 140 M2E 068-CF
*2E 140 M2E 068-DF
subject to alterations
100 200 300 400
0 50 150 250 [CFM]100 200
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
1
2
B
1
2
A
Curves
1900
2200
2485
2630
n[rpm]
P1
[W]I
[A]
128
117
148
128
0.57
0.52
0.65
0.57
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 385 1650 135 0.60 2.0 /400 63 0 -25 to +551~ 230 60 305 1700 145 0.64 2.0 /400 60 100 -25 to +40
1~ 230 50 485 2400 160 0.70 4.0 /400 72 0 -25 to +701~ 230 60 480 2350 205 0.90 4.0 /400 71 0 -25 to +45
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
109
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal fan
R2E 140-AL40 -05
R2E 140-AI28 -05
Dimensions
kg
1.7
2.1
d e
73.0 25.0
83.0 35.0
Centrifugal blowerwith flange
G2E 140-AL40 -01
G2E 140-AI28 -01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
3.0
3.4
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø12
1
2
±172
d±1
e
±0,
1Ø
27
±20450
6
Ø92
Ø14
0
59
5
Ø11
8-1
450
6,3
107
103
158
227
M4
130
115
94
92
100
120
105
248
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
110
AC centrifugal blowerssingle inlet, Ø 140
– Material: Housing: Heat-resistant plastic
Impeller: heat-resistant plastic, galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
Nominal data
Type Motor
G2E 140 M2E 068-BF
G2E 140 M2E 068-CF
subject to alterations
100 200 300
0 50 100 150
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
500
200 [CFM]
B
A
2
1
2
1
60 Hz50 Hz
Curves
1910
2280
2220
2470
n[rpm]
P1
[W]I
[A]
98
86
123
105
0.43
0.38
0.54
0.46
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 370 1650 105 0.46 2.0 /400 59 0 -25 to +551~ 230 60 315 1700 115 0.51 2.0 /400 57 50 -25 to +40
1~ 230 50 445 2000 137 0.60 3.0 /400 65 0 -25 to +651~ 230 60 390 2150 155 0.68 3.0 /400 64 130 -25 to +50
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
111
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal blowerwithout flange
G2E 140-NS38 -01
G2E 140-NL33 -01
kg
1.6
1.6
95
237
22 248
261
267
35
Ø10
1
111
113
100
±20
±1
±1
±0,3
Ø12
5,5
6
85
450
Terminal boxp. 562
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l blo
wer
Brass lead tipsG
en
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
112
AC centrifugal fan and blowersingle inlet, Ø 146
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 146 M2E 068-CA
subject to alterations
100 200 300 400
0 50 100 [CFM]150 200 250
[Pa]
100
200
300
400
500
0,5
1,0
1,5
2,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1835
2070
n[rpm]
P1
[W]I
[A]
136
126
0.60
0.56
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 470 1550 140 0.62 3.0 /450 60 0 -25 to +501~ 230 60 380 1750 155 0.68 3.0 /450 58 100 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
113
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal fan
R2E 146-AW07 -05
kg
1.4
Centrifugal blowerwith flange
G2E 146-DW07-01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
2.6
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø12
7
2
±172
68±1
20
±0,
1Ø
27
±20450
6
Ø92
Ø14
6
62
5
Ø12
5,5
-1
450
6,3
107
101
158
227
M4
130
115
94
92
104
120
105
248
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
114
AC centrifugal fans and blowerssingle inlet, Ø 160
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*2E 160 M2E 068-EC
*4E 160 M4E 068-CF
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
100
200
300
400
500
600
700
0,5
1,0
1,5
2,0
[in H
2O
]2
,5
[m3/h]
60 Hz50 Hz
1
2
2
1
A
B
Curves
2210
2525
1350
1395
n[rpm]
P1
[W]I
[A]
223
172
63
58
0.98
0.76
0.28
0.26
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 600 2100 240 1.05 6.0 /400 72 0 -25 to +501~ 230 60 570 2100 280 1.23 6.0 /400 71 50 -25 to +40
1~ 230 50 410 1300 67 0.30 2.0 /450 65 0 -25 to +651~ 230 60 445 1400 90 0.40 2.0 /450 67 0 -25 to +65
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
115
– Motor protection: TOP wired internally
– Cable exit: variable, lateral
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
BA
Centrifugal fan
R2E 160-AY47 -01
R4E 160-AB01 -01
Dimensions
kg
2.6
1.7
d e
91.0 42.0
72.0 25.0
Centrifugal blowerwith flange
G2E 160-AY47 -01
G4E 160-AB01 -01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
3.9
2.9
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4±0,1
58
Ø13
1
2
±172
d ±1
e
±0,
1Ø
27
±20450
6
Ø92
Ø16
0
62
5
Ø13
0-1
450
6,3
107
103
175
227
M4
130
115
94
92
100
120
105
248
Depth of screw
max. 5 mmBrass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
116
AC centrifugal fan and blowersingle inlet, Ø 180
– Material: Housing: Die-cast aluminium
Impeller: Galvanised sheet steel
Rotor: coated in black, partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
Nominal data
Type Motor
G2E 180 M2E 074-EI
*4E 180 M4E 068-DF
subject to alterations
[m3/h]
[CFM]
[Pa]
[in H
2O
]
60 Hz50 Hz
300100
0
200
100
400 500
200
1,0
600 700
400
600
800
2,0
3,0
200 300 400
1
1
2
2
A
B
Curves
2290
2600
1300
1385
n[rpm]
P1
[W]I
[A]
335
255
105
92
1.47
1.12
0.47
0.41
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 760 1950 400 1.75 8.0 /400 73 0 -25 to +401~ 230 60 630 2150 415 1.82 8.0 /400 71 250 -25 to +40
1~ 230 50 575 1250 110 0.49 3.0 /450 65 0 -25 to +551~ 230 60 594 1300 145 0.64 3.0 /450 65 0 -25 to +45
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
117
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
—
R4E 180-AB01 -05
kg
—
1.7
Centrifugal blowerwith flange
G2E 180-EH03 -01
G4E 180-AB01 -01
Terminal boxp. 562
Air filterp. 563
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
5.6
3.7
Mas
s of
ce
ntri
fuga
l blo
wer
Ø55
M4
±0,158
Ø14
9
2
±189
82±1
e
±0,
1Ø
27
±20450
6
Ø92
Ø18
0
75
5
Ø15
0 -1 450
7
123
120
194
261
M4
125
110
86
110
105
140
120
281
Depth of screw
max. 5 mmBrass lead tips
Motor
protruding
by 15 mm!
A
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
Dimensions
e
48.0
35.0
118
AC centrifugal fan and blowersingle inlet, Ø 180
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 180(2) M4D 074-DF
G4D 180 (1)(2) M4D 074-DF
subject to alterations
200 400 800 1000600
0 200 400 600 [CFM]
[Pa]
50
100
150
200
250
300
0,2
51
,25
0,5
0,7
51
,0[in
H2O
]
[m3/h]
60 Hz50 Hz
1
1
2
2
A
B
Curves
1360
1410
1360
1420
n[rpm]
P1
[W]
160
120
163
105
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
C1)/C2)3~ 230/400 50 1010 1330 175 0.68/0.39 — 67 0 -25 to +603~ 230/400 60 1090 1440 240 0.74/0.43 — 69 0 -25 to +55
3~ 230/400 50 1110 1290 195 0.69/0.40 — 69 0 -25 to +603~ 230/400 60 1180 1370 265 0.81/0.47 — 70 0 -25 to +45
A
C1)/C2)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, 1 m length) (2) 230 VAC ∆ / 400 VAC Y
I[A]
0.62/0.36
0.46/0.27
0.58/0.33
0.38/0.22
119
– Motor protection: Without thermal protection
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R4D 180-AF20 -05
—
kg
3.2
—
Dimensions
C D E S
188.0 168.0 134.0 90.0
278.0 258.0 224.0 180.0
Centrifugal blowerwith flange (small)
G4D 180-FF20 -01
—
Centrifugal blowerwith flange (large)
—
G4D 180-GF20 -01
Terminal boxp. 562
Guard grillep. 554
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
6.4
6.4
Mas
s of
ce
ntri
fuga
l blo
wer
692
Ø75
600± 20
±0,
1
Ø18
0
Ø14
9
Ø10
2
35
5
±1104
120,5±1
37
90±0,2
M6
Ø14
9-1
C SD
155
163
183
129
90
7
600
E
192
3,2
6x60˚
296
5˚
133
136
332
Depth of screw
max. 10 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
120
AC centrifugal fan and blowersingle inlet, Ø 180
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 180 M4E 074-DF
G4E 180 (1) M4E 074-DF
subject to alterations
200 400 600 800
0 200 400 [CFM]
[Pa]
50
100
150
200
250
300
0,2
50
,50
,75
1,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
11
22
A
B
Curves
1280
1375
1210
1340
n[rpm]
P1
[W]I
[A]
142
112
160
123
0.63
0.50
0.71
0.55
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 965 1220 160 0.71 4.0 /400 66 0 -25 to +601~ 230 60 935 1200 197 0.87 4.0 /400 65 0 -25 to +40
1~ 230 50 1030 1130 180 0.80 4.0 /400 66 0 -25 to +451~ 230 60 910 1170 200 0.88 4.0 /400 64 50 -25 to +35
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, length 1 m)
121
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R4E 180-AS11 -05
—
kg
3.2
—
Dimensions
C D E S
188.0 168.0 134.0 90.0
278.0 258.0 224.0 180.0
Centrifugal blowerwith flange (small)
G4E 180-FS11 -01
—
Terminal boxp. 562
Guard grillep. 554
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
6.4
6.4
Mas
s of
ce
ntri
fuga
l blo
wer
692
Ø75
600± 20
±0,
1
Ø18
0
Ø14
9
Ø10
2
35
5
±1104
120,5±1
37
90±0,2
M6
Ø14
9-1
C SD
155
163
183
129
90
7
600
E
192
3,2
6x60˚
296
5˚
133
136
332
Depth of screw
max. 10 mm
Brass lead tips
Hole with
large flange only
B
Centrifugal blowerwith flange (large)
—
G4E 180-GS11 -01
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
122
AC centrifugal fan and blowersingle inlet, Ø 200
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4D 200 (2) M4D 074-EI
G4D 200 (1)(2) M4D 074-EI
subject to alterations
400 1200800
0 200 400 600 [CFM]800
[Pa]
50
100
150
200
250
300
350
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
1 1
2 2
A
B
Curves
1375
1415
1315
1385
n[rpm]
P1
[W]
255
192
330
230
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
C1)/C2)3~ 230/400 50 1375 1350 285 1.00/0.58 — 69 0 -25 to +453~ 230/400 60 1360 1530 360 1.13/0.65 — 69 100 -25 to +45
3~ 230/400 50 1665 1300 360 1.14/0.66 — 71 0 -25 to +453~ 230/400 60 1220 1550 340 1.07/0.62 — 69 250 -25 to +40
A
C1)/C2)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, 1 m length) (2) 230 VAC ∆ / 400 VAC Y
I[A]
0.90/0.52
0.68/0.39
1.05/0.61
0.74/0.43
123
– Motor protection: Without thermal protection
– Cable exit: Axial
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal fan
R4D 200-AL12 -05
—
kg
3.7
—
Dimensions
C D E S
200.0 180.0 146.0 90.0
304.0 284.0 250.0 180.0
Centrifugal blowerwith flange (small)
G4D 200-BL12 -01
—
Terminal boxp. 562
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
7.0
7.0
Mas
s of
ce
ntri
fuga
l blo
wer
6102
Ø75
600± 20
±0,
1
Ø20
2
Ø17
6
Ø10
2
48
5
±1117
129 ±1
37
90 ±0,2
M6
Ø17
5
C SD
160,5
176,5
196,5
142,5
90
7
600
E
213
3,2
6x60˚
327
5˚
146
151
370
Depth of screw
max. 10 mm
Brass lead tips
Hole with
large flange only
B
Centrifugal blowerwith flange (large)
—
G4D 200-CL12 -01
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
124
AC centrifugal fans and blowerssingle inlet, Ø 200
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
*4E 200 M4E 074-EI
G4E 200 (1) M4E 074-EI
subject to alterations
400 800 1200
0 200 400 800 [CFM]600
[Pa]
50
150
100
200
250
300
350
400
0,5
1,0
[in H
2O
]1
,5
[m3/h]
60 Hz50 Hz
11
2 2
A
B
Curves
1350
1400
1285
1370
n[rpm]
P1
[W]I
[A]
258
214
303
242
1.15
0.96
1.33
1.07
A
B
A
B
1
2
2
1
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 1370 1300 280 1.25 8.0 /400 69 0 -25 to +401~ 230 60 1315 1480 350 1.55 8.0 /400 69 100 -25 to +40
1~ 230 50 1540 1240 330 1.45 8.0 /400 70 0 -25 to +501~ 230 60 1300 1430 370 1.62 8.0 /400 68 170 -25 to +40
A
A1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, length 1 m)
125
– Motor protection: TOP wired internally
– Cable exit: Axial
– Protection class: I
– Capacitor: FPU (P2) acc. to IEC 252
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, also GOSTB
Centrifugal fan
R4E 200-AL03 -05
—
kg
3.7
—
Dimensions
C D E S
200.0 180.0 146.0 90.0
304.0 284.0 250.0 180.0
Centrifugal blowerwith flange (small)
G4E 200-BL03 -01
—
Terminal boxp. 562
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Mas
s of
ce
ntri
fuga
l fan
kg
7.0
7.0
Mas
s of
ce
ntri
fuga
l blo
wer
Centrifugal blowerwith flange (large)
—
G4E 200-CL03 -01
6102
Ø75
600± 20
±0,
1
Ø20
2
Ø17
6
Ø10
2
48
5
±1117
129 ±1
37
90 ±0,2
M6
Ø17
5
C SD
160,5
176,5
196,5
142,5
90
7
600
E
213
3,2
6x60˚
327
5˚
146
151
370
Depth of screw
max. 10 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
126
AC centrifugal fan and blowersingle inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*4D 225
G4D 225 (2)
subject to alterations
400 800 1200 1600
0 250 500 1000 [CFM]750
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1 1
A
B
Curves
1380
1420
1345
1400
n[rpm]
P1
[W]I
[A]
325
228
388
271
0.69
0.60
0.76
0.64
A
B
A
B
1
2
2
1
LpA
[dB(A)]
71
67
74
69
Motor
M4D 094-FA
M4D 094-FA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
D2)3~ 400 Y 50 1350 380 0.75 — 0 -40 to +903~ 400 Y 60 1500 540 0.94 — 50 -40 to +55
3~ 400 Y 50 1310 460 0.85 — 0 -40 to +753~ 400 Y 60 1520 515 0.90 — 200 -40 to +60
A
D2)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
127
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Options: 400 VAC ∆/Y for two speed steps available on requestB
Centrifugal fan
R4D 225-AK10 -06
—
kg
6.5
—
Dimensions
C D E S
200.0 180.0 146.0 90.0
304.0 284.0 250.0 180.0
Centrifugal blowerwith flange (small)
G4D 225-FK10 -03
—
Centrifugal blowerwith flange (large)
—
G4D 225-GK10 -03
Mas
s of
ce
ntri
fuga
l fan
kg
9.5
9.7
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
600
Ø115
M645˚102
50
225
±2
Ø19
5±
1
Ø12
4
137,5 ±2
128 ±25,5
Ø10
0+
0,5
600
DC
176,5
166,5
Ø19
4
S
5,5
7 E
90
142,5
196,5
3,2
242
6x60˚
5˚
151
370
327
158
Depth of screw
max. 12 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
128
AC centrifugal fan and blowersingle inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*4E 225
G4E 225 (2)
subject to alterations
400 800 1200 1600
0 250 500 1000 [CFM]750
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
11
2 2
A
B
Curves
1365
1415
1320
1395
n[rpm]
P1
[W]I
[A]
339
255
401
292
1.75
1.46
2.00
1.57
A
B
A
B
1
2
2
1
LpA
[dB(A)]
67
70
74
69
Motor
M4E 094-FA
M4E 094-FA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1330 395 1.98 6.0 /450 0 -40 to +701~ 230 60 1500 500 2.30 6.0 /450 100 -40 to +50
1~ 230 50 1260 485 2.30 6.0 /450 0 -40 to +551~ 230 60 1470 510 2.30 6.0 /450 200 -40 to +45
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
129
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
Centrifugal fan
R4E 225-BK05 -03
—
kg
6.6
—
Dimensions
C D E S
200.0 180.0 146.0 90.0
304.0 284.0 250.0 180.0
Centrifugal blowerwith flange (small)
G4E 225-DK05 -03
—
Centrifugal blowerwith flange (large)
—
G4E 225-EK05 -03
Mas
s of
ce
ntri
fuga
l fan
kg
9.6
9.8
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
600
Ø115
M645˚102
50
225
±2
Ø19
5±
1
Ø12
4
137,5 ±2
128 ±25,5
Ø10
0+
0,5
600
DC
176,5
166,5
Ø19
4
S
5,5
7 E
90
142,5
196,5
3,2
242
6x60˚
5˚
151
370
327
158
Depth of screw
max. 12 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
130
AC centrifugal fan and blowersingle inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*4D 250
G4D 250 (2)
subject to alterations
400 1000 1600 2200
0 250 500 1250 [CFM]750 1000
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]2
,0
[m3/h]
60 Hz50 Hz
2 2
11
A
B
Curves
1390
1430
1330
1410
n[rpm]
P1
[W]I
[A]
444
312
654
386
0.99
0.87
1.13
0.94
A
B
A
B
1
2
2
1
LpA
[dB(A)]
72
70
76
71
Motor
M4D 094-HA
M4D 094-HA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
D2)3~ 400 Y 50 1350 590 1.17 — 0 -40 to +803~ 400 Y 60 1560 710 1.26 — 150 -40 to +60
3~ 400 Y 50 1280 800 1.46 — 0 -40 to +503~ 400 Y 60 1560 700 1.24 — 300 -40 to +55
A
D2)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
131
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Options: 400 VAC ∆/Y for two speed steps available on request
Centrifugal fan
R4D 250-AC10 -03
—
kg
9.7
—
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
313.0 285.0 262.0 180.0 293.0
Centrifugal blowerwith flange (small)
G4D 250-DC10 -03
—
Centrifugal blowerwith flange (large)
—
G4D 250-EC10 -03
Mas
s of
ce
ntri
fuga
l fan
kg
13.1
13.5
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
600
Ø115
M645˚140
70
Ø24
0±
2
Ø19
2±
1
Ø12
4
175,5±2
148±25,5
Ø10
0+
0.5
6x60˚C U D S
Ø20
0
205,5
207
5,5
7
E
90
176
227
206
3,2
275
173
392
387
194
600
Depth of screw
max. 12 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
132
AC centrifugal fan and blowersingle inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*4E 250
G4E 250(2)
subject to alterations
400 1000 1600 2200
0 250 500 1250 [CFM]750 1000
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]2
,0
[m3/h]
60 Hz50 Hz
2 2
11
A
B
Curves
1370
1420
1310
1390
n[rpm]
P1
[W]I
[A]
448
325
560
395
2.25
1.85
2.73
2.05
A
B
A
B
1
2
2
1
LpA
[dB(A)]
70
68
73
69
Motor
M4E 094-HA
M4E 094-HA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1310 570 2.48 10.0 /450 0 -40 to +701~ 230 60 1470 690 3.05 10.0 /450 100 -40 to +55
1~ 230 50 1150 760 3.80 10.0 /450 0 -40 to +451~ 230 60 1400 730 3.30 10.0 /450 220 -40 to +55
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
133
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
Centrifugal fan
R4E 250-BA09 -03
—
kg
9.3
—
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
313.0 285.0 262.0 180.0 293.0
Centrifugal blowerwith flange (small)
G4E 250-DA09 -03
—
Centrifugal blowerwith flange (large)
—
G4E 250-EA09 -03
Mas
s of
ce
ntri
fuga
l fan
kg
12.7
13.1
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
600
Ø115
M645˚140
70
Ø24
0±
2
Ø19
2±
1
Ø12
4
175,5±2
148±25,5
Ø10
0+
0.5
6x60˚C U D S
Ø20
0
205,5
207
5,5
7
E
90
176
227
206
3,2
275
173
392
387
194
600
Depth of screw
max. 12 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
134
AC centrifugal fan and blowerssingle inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*6E 250
G6E 250 (2)
subject to alterations
400 800 1200 1600
0 250 500 1000 [CFM]750
[Pa]
50
100
150
200
0,2
50
,50
,75
[in H
2O
]
[m3/h]
60 Hz50 Hz
11
2 2
A
B
Curves
900
930
855
910
n[rpm]
P1
[W]I
[A]
180
156
215
173
0.82
0.74
0.96
0.79
A
B
A
B
1
2
2
1
LpA
[dB(A)]
63
61
65
62
Motor
M6E 094-FA
M6E 094-FA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 850 220 1.00 6.0 /450 0 -40 to +801~ 230 60 900 295 1.30 6.0 /500 0 -40 to +80
1~ 230 50 780 255 1.15 6.0 /450 0 -40 to +801~ 230 60 760 305 1.35 6.0 /500 0 -40 to +70
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
135
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
Centrifugal fan
R6E 250-AK05 -03
—
kg
7.0
—
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
313.0 285.0 262.0 180.0 293.0
Centrifugal blowerwith flange (small)
G6E 250-DK05 -03
—
Centrifugal blowerwith flange (large)
—
G6E 250-EK05 -03
Mas
s of
ce
ntri
fuga
l fan
kg
10.5
10.9
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
600
Ø115
M645˚140
50
Ø24
0±
2
Ø19
2±
1
Ø12
4
175,5±2
128±25,5
Ø10
0+
0.5
6x60˚C U D S
Ø20
0
205,5
207
5,5
7
E
90
176
227
206
3,2
275
173
392
387
194
600
Depth of screw
max. 12 mm
Brass lead tips
Hole with
large flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
136
AC centrifugal fanssingle inlet, Ø 250
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R4D 250 (2)
R4E 250
subject to alterations
400 800 1200 1600 2000
0 250 [CFM]500 750 1000 1250
[Pa]
50
100
150
200
[in H
2O
]0
,60
,8
250 1,0
300 1,2
350 1,4
0,4
0,2
[m3/h]
1
2
1
2
A
B
Curves
1430
1460
1370
1430
n[rpm]
P1
[kW]
0.53
0.32
0.49
0.33
A
B
A
B
1
2
2
1
LpA
[dB(A)]
77
70
76
70
Motor
M4D 110-GF
M4E 110-GF
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 1400 0.75 2.77/1.60 — 0 -25 to +80
1~ 230 50 1270 0.64 2.80 12.0 /450 0 -25 to +80
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
2.48/1.43
2.23/1.29
2.14
1.49
137
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R4D 250-CG01 -01
R4E 250-CG01 -01
kg
12.0
12.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
25010-2-4013 94250-2-4017
25010-2-4013 94250-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Housing width
View Z
138
198
213
230
247
267
287
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
184
170
158
147
18
203
150
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
138
AC centrifugal fanssingle inlet, Ø 250
– Material: Impeller: Galvanised sheet steel
Rotor: cast in aluminium, coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: on rotor and stator sides, none
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
BA
Nominal data
Type
R6D 250 (2)
R6E 250
subject to alterations
[m3/h]
[CFM]
[Pa]
[in H
2O
]
600200
0
400
200
800 1000
40
0,2
1200 1400
80
120
160
0,4
0,6
400 600 800
1
2
1
2
A
B
B
A
Curves
945
965
875
930
n[rpm]
P1
[kW]
0.23
0.17
0.22
0.17
A
B
A
B
1
2
2
1
LpA
[dB(A)]
68
63
67
62
Motor
M6D 110-EF
M6E 094-FA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 930 0.27 1.25/0.72 — 0 -25 to +95
1~ 230 50 800 0.26 1.16 6.0 /450 0 -25 to +90
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
1.18/0.68
1.11/0.64
1.00
0.81
139
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)A
Centrifugal fan
R6D 250-CE01 -01
R6E 250-CA08 -01
kg
9.5
7.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
25010-2-4013 94250-2-4017
25010-2-4013 94250-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions A
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Mounting dimensions B
28
55
Ø100
Ø115
4x90
˚
Ø 7
Housing width
View Z
Dimensions
l
800.0
600.0
138
198
213
230
247
267
287
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
184
170
158
147
18
203
150
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
140
AC centrifugal fan and blowersingle inlet, Ø 280
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
*4E 280
subject to alterations
400 800 1200 1600 2000
0 200 600 800 [CFM]400 1000 1200
[Pa]
[in H
2O
]
[m3/h]
60 Hz50 Hz
200
1,0
400
600
800
2,0
3,0
A
2
1
Curves
1250
1380
n[rpm]
P1
[W]I
[A]
845
555
4.20
3.02
A
A
1
2
LpA
[dB(A)]
73
73
Motor
M4E 094-HA
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1100 1080 5.30 12.0 /400 100 -40 to +601~ 230 60 1350 990 4.70 12.0 /450 400 -40 to +55
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
141
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
Centrifugal fan
R4E 280-CC21 -01
kg
10.2
Centrifugal blowerwith flange (small)
G4E 280-CA21 -01
Mas
s of
ce
ntri
fuga
l fan
kg
14.0
Mas
s of
ce
ntri
fuga
l blo
wer
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
600
Ø115
M645˚114
70
Ø28
0±
2
Ø23
4±
1
Ø12
4
149,5±2
148±25,5
Ø10
0+
0.5
5x60˚
348
322
316
200
Ø23
6
172
180
3,5
10
280
100
149
200
176
M6
315
175
444
412
190
600
Depth of screw
max. 12 mm
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
142
AC centrifugal fanssingle inlet, Ø 280
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R4D 280 (2)
R4E 280
subject to alterations
500 1000 1500 2000 2500 3000
0 500 [CFM]1000 1500
[Pa]
100
200
300
400
[in H
2O
]1
,21
,6
500 2,0
600 2,4
0,8
0,4
[m3/h]
1
1
2
B
A
Curves
1390
1440
1340
1425
n[rpm]
P1
[kW]
0.87
0.51
0.82
0.54
A
B
A
B
1
2
2
1
LpA
[dB(A)]
77
72
76
72
Motor
M4D 110-IA
M4E 110-IA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 1330 1.32 4.75/2.75 — 0 -25 to +65
1~ 230 50 1230 1.05 4.75 16.0 /450 100 -25 to +50
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
3.79/2.19
3.29/1.90
3.59
2.34
143
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R4D 280-CI03 -01
R4E 280-CI01 -01
kg
14.5
14.5
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
28010-2-4013 10280-2-4017
28010-2-4013 10280-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Housing width
View Z
162
183
200
218
236
254
266
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
172
161
148
152
13
205
180
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
144
AC centrifugal fanssingle inlet, Ø 280
– Material: Impeller: Galvanised sheet steel
Rotor: cast in aluminium, coated in black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: on rotor and stator sides, none
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
BA
Nominal data
Type
R6D 280 (2)
R6E 280
subject to alterations
400 800 1600 20001200
0 400 800 1200 [CFM]
[Pa]
50
100
150
200
250
300
0,2
51
,25
0,5
0,7
51
,0[in
H2O
]
[m3/h]
B
A
1
1
2
2
Curves
930
960
890
940
n[rpm]
P1
[kW]
0.29
0.18
0.34
0.27
A
B
A
B
1
2
2
1
LpA
[dB(A)]
66
61
66
61
Motor
M6D 110-EF
M6E 094-HA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 870 0.45 1.56/0.90 — 0 -25 to +70
1~ 230 50 795 0.42 1.95 12.0 /450 0 -25 to +55
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
1.30/0.75
1.16/0.67
1.60
1.37
145
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)A
Centrifugal fan
R6D 280-CE01 -01
R6E 280-CC05 -01
kg
10.0
9.5
Dimensions
l
800.0
600.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
28010-2-4013 10280-2-4017
28010-2-4013 10280-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions A
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Mounting dimensions B
28
55
Ø100
Ø115
4x90
˚
Ø 7
Housing width
View Z
162
183
200
218
236
254
266
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
172
161
148
152
13
205
180
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
146
AC centrifugal fansingle inlet, Ø 310
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R4D 310 (2)
subject to alterations
1000 2000 3000 4000
0 500 [CFM]1000 1500 25002000
[Pa]
100
200
300
400
500
600
[in H
2O
]1
,21
,62
,00
,80
,4
[m3/h]
1
2
A
Curves
1330
1410
n[rpm]
P1
[kW]
1.96
1.12
A
A
1
2
LpA
[dB(A)]
82
77
Motor
M4D 138-HF
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 1310 2.18 6.75/3.90 — 0 -25 to +55A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
6.29/3.63
4.43/2.56
147
– Motor protection: Design with thermal overload protector
– Cable exit: Lateral
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R4D 310-CK03 -01
kg
24.5
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
31010-2-4013 38310-2-4017
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tipsDepth of screw
max. 18 mm
Housing width
View Z
176
246
264
283
303
325
349
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
229
214
200
186
18
249
184
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
148
AC centrifugal fanssingle inlet, Ø 310
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R6D 310 (2)
R6E 310
subject to alterations
500 1000 1500 2000 2500 3000
0 250 [CFM]500 750 1000 1250 1500 1750
[Pa]
50
100
150
200
[in H
2O
]0
,60
,8
250 1,0
300 1,2
0,4
0,2
[m3/h]
2
B
A
2
1
1
Curves
870
930
900
950
n[rpm]
P1
[kW]
0.65
0.40
0.58
0.42
A
B
A
B
1
2
2
1
LpA
[dB(A)]
72
67
70
65
Motor
M6D 110-GF
M6E 110-IA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 840 0.76 2.50/1.45 — 50 -25 to +50
1~ 230 50 800 0.77 3.37 16.0 /400 0 -25 to +65
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
2.25/1.30
1.75/1.01
2.81
2.32
149
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R6D 310-CG03 -01
R6E 310-CI01 -01
kg
12.5
15.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
31010-2-4013 10310-2-4017
31010-2-4013 10310-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Housing width
View Z
176
246
264
283
303
325
349
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
229
214
200
186
18
249
184
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
150
AC centrifugal fansingle inlet, Ø 355
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R4D 355 (2)
subject to alterations
1000 2000 3000 4000 5000 6000 7000
0 [CFM]1000 2000 3000 4000
[Pa]
100
200
300
400
[in H
2O
]1
,21
,6
500 2,0
600 2,4
700 2,8
800
0,8
0,4
[m3/h]
1
2
A
Curves
1370
1430
n[rpm]
P1
[kW]
3.20
1.89
A
A
1
2
LpA
[dB(A)]
86
80
Motor
M4D 138-LA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 1300 4.36 13.75/7.95 — 0 -25 to +70A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
10.58/6.11
7.52/4.34
151
– Motor protection: Design with thermal overload protector
– Cable exit: Lateral
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R4D 355-CM03 -01
kg
28.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
35510-2-4013 38355-2-4017
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tipsDepth of screw
max. 18 mm
Housing width
View Z
196
274
294
315
338
362
389
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
256
238
222
207
18
280
203
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B
B
1
2
152
AC centrifugal fanssingle inlet, Ø 355
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: On rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R6D 355 (2)
R6E 355
subject to alterations
1000 2000 3000 4000
0 500 [CFM]1000 1500 2000 2500
[Pa]
100
200
300
400
[in H
2O
]0
,81
,20
,4
[m3/h]
1
2
1
2
B
A
Curves
890
920
830
890
n[rpm]
P1
[kW]
0.78
0.59
0.83
0.61
A
A
1
2
LpA
[dB(A)]
70
68
70
67
Motor
M6D 110-IA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 865 0.90 3.05/1.77 — 250 -25 to +50A
M6E 110-IA A2a)1~ 230 50 830 0.83 3.90 16.0 /400 175 -25 to +55B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
2.82/1.63
2.44/1.41
3.90
2.90
153
– Motor protection: Design with thermal overload protector
– Cable exit: Diagonal
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R6D 355-CI05 -01
kg
15.5
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
35510-2-4013 10355-2-4017
R6E 355-CI01 -01 15.5 35510-2-4013 10355-2-4017
Inlet nozzlep. 552
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tips
Depth of screw
max. 12 mm
Mounting dimensions
28
130
Ø100
Ø115
4x90
˚
Ø
Ø
7
Housing width
View Z
196
274
294
315
338
362
389
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
256
238
222
207
18
280
203
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
154
AC centrifugal fansingle inlet, Ø 400
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
Nominal data
Type
R4D 400 (2)
subject to alterations
ohne Spannungssteuerung einsetzbar
2000 4000 6000 8000
0 [CFM]1000 2000 3000 50004000
[Pa]
200
400
600
800
[in H
2O
]2
,43
,2
1000 4,0
1,6
0,8
[m3/h]
1
2
A
Curves
1210
1300
n[rpm]
P1
[kW]
4.92
3.70
A
A
1
2
LpA
[dB(A)]
87
86
Motor
M4D 138-NA
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 1210 4.92 14.70/8.50 — 550 (3) -25 to +35A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y (3) without voltage control
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
14.70/8.50
11.19/6.46
155
– Motor protection: Design with thermal overload protector
– Cable exit: Lateral
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R4D 400-CO01 -01
kg
32.5
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
40010-2-4013 38400-2-4017
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tipsDepth of screw
max. 18 mm
Housing width
View Z
220
308
331
355
380
408
437
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
288
268
250
233
20
316
228
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
156
AC centrifugal fanssingle inlet, Ø 400
– Material: Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 20, IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharge holes: none, on rotor and stator sides
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings
BA
BA
Nominal data
Type
R6D 400 (2)
R8D 400 (2)
subject to alterations
1000 2000 3000 4000 5000 6000
0 [CFM]500 1000 1500 2500 3000 35002000
[Pa]
100
200
300
400
[in H
2O
]1
,21
,6
500
0,8
0,4
[m3/h]
1
2
1
2
B
A
Curves
890
940
615
675
n[rpm]
P1
[kW]
1.86
1.16
0.89
0.60
A
B
A
B
1
2
2
1
LpA
[dB(A)]
80
74
71
67
Motor
M6D 138-LA
M8D 138-HF
VAC Hz rpm kW A µF/VDB Pa °C p. 596 f.
D1)/D2)3~ 230/400 50 840 2.40 8.47/4.90 — 0 -25 to +75
3~ 230/400 50 615 0.89 3.46/2.00 — 100 -25 to +65
A
D1)/D2)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) Nominal data in operating point with maximum load (2) 230 VAC ∆ / 400 VAC Y
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
I[A]
7.10/4.10
5.51/3.18
3.46/2.00
2.74/1.58
157
– Motor protection: Design with thermal overload protector
– Cable exit: Lateral
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: VDE (acc. to EN 60034)
Centrifugal fan
R6D 400-CM05 -01
R8D 400-CK05 -01
kg
29.0
26.0
Mas
s of
ce
ntri
fuga
l fan
Inlet nozzle Flange
40010-2-4013 38400-2-4017
40010-2-4013 38400-2-4017
Inlet nozzlep. 552
Electr. connectionsp. 596 f.
View without flange View with flange
Brass lead tipsDepth of screw
max. 18 mm
Housing width
View Z
220
308
331
355
380
408
437
30˚
30˚
30˚65˚
30˚
30˚30˚ 30˚ 30
˚
30˚
25˚
288
268
250
233
20
316
228
Scroll housing used:
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
158
AC centrifugal blowersdual inlet, Ø 140
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 140 M2E 068-CF
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
Step 4
Step 3
Step 1
Step 2
2
4
6
8
1
3
5
7
A
Curves
1675
2235
1385
2020
1000
1540
690
1015
n[rpm]
P1
[W]I
[A]
118
100
93
80
73
68
56
55
0.51
0.43
0.41
0.36
0.33
0.31
0.26
0.25
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 470 1150 130 0.58 2.0 /400 58 0 -25 to +501~ 230 60 430 1050 130 0.58 2.0 /400 56 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
56
59
52
56
46
49
36
38
1
45
6
23
159
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE
Centrifugal blower with flange
D2E 140-HR97 -07
kg
2.3
5
N
L1
6
PE
12 3
4
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
160
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: PA plastic, red-brown
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted via support plate
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-CA
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
50
100
150
200
250
300
0,4
0,8
1,2
[in H
2O
]
[m3/h]
60 Hz50 Hz
8
5
3
1
6
4
2
A
Step 4
Step 3
Step 2
7
Step 1
Curves
1635
2115
1210
1740
925
1355
660
960
n[rpm]
P1
[W]I
[A]
113
104
72
66
58
55
48
46
0.49
0.45
0.36
0.35
0.31
0.30
0.27
0.26
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 520 1350 120 0.53 3.0 /400 51 50 -25 to +551~ 230 60 375 1400 125 0.55 3.0 /400 53 100 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
55
58
48
53
40
47
31
38
1
45
6
23
161
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE
Centrifugal blower with flange
D2E 146-KA45 -01
kg
2.5
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
162
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: PA plastic, red-brown
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted via support plate
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-CF
subject to alterations
100 200 300 400 500 600
0 100 200 300 [CFM]
[Pa]
50
100
150
200
250
300
350
400
0,4
0,8
1,2
[in H
2O
]
[m3/h]
60 Hz50 Hz
Step 4
Step 3
Step 2
Step 1
1
3
5
7
2
4
6
8
A
Curves
1675
2185
1230
1800
950
1440
660
960
n[rpm]
P1
[W]I
[A]
151
136
101
92
85
80
71
68
0.66
0.60
0.50
0.47
0.43
0.42
0.37
0.36
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 665 1250 160 0.70 4.0 /400 53 0 -25 to +501~ 230 60 390 1950 170 0.75 4.0 /400 58 200 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
59
62
50
55
43
49
31
38
1
45
6
23
163
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE
Centrifugal blower with flange
D2E 146-KB27 -01
kg
2.7
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
164
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-CF
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
Step 1
Step 3
Step 4
2
4
Step 2
6
8
1
3
5
7
A
Curves
1490
2005
1110
1635
890
1315
680
990
n[rpm]
P1
[W]I
[A]
143
133
98
92
81
77
69
67
0.62
0.59
0.49
0.47
0.42
0.42
0.38
0.37
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 630 1100 150 0.66 4.0 /400 51 0 -25 to +501~ 230 60 415 1600 160 0.71 4.0 /400 55 150 -25 to +45
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
51
55
47
49
37
43
31
35
1
45
6
23
165
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE, CCC, GOST
Centrifugal blower with flange
D2E 146-HR93 -03
kg
3.0
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
166
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: PP plastic, white
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-DF
subject to alterations
200 400 600
0 100 200 300 [CFM]400
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
Step 1
Step 2
Step 3
Step 4
1
3
5
7
2
4
6
8
A
Curves
1790
2290
1210
1820
910
1415
710
1055
n[rpm]
P1
[W]I
[A]
185
164
125
112
106
100
94
91
0.81
0.72
0.60
0.57
0.52
0.50
0.47
0.46
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 755 1350 195 0.86 5.0 /400 57 0 -25 to +551~ 230 60 580 1750 215 0.94 5.0 /400 54 150 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
56
59
45
52
38
45
30
38
1
45
6
23
167
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE, GOST
Centrifugal blower with flange
D2E 146-HS97 -03
kg
3.5
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
168
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on plug
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box, EW motor
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-EC
subject to alterations
200 400 600 800
0 150 300 450 [CFM]
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
Step 1
Step 2
Step 3
Step 4
2
4
6
8
1
3
5
7
A
Curves
2075
2430
1770
2230
1375
1885
1000
1415
n[rpm]
P1
[W]I
[A]
328
269
268
222
225
197
192
180
1.42
1.17
1.20
1.04
1.03
0.94
0.88
0.84
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 1060 1850 355 1.55 8.0 /450 66 0 -25 to +501~ 230 60 875 2100 400 1.75 8.0 /450 63 200 -25 to +55
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
66
61
61
62
54
57
45
49
1
45
6
23
169
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: VDE
Centrifugal blower with flange
D2E 146-HT67 -02
kg
3.6
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
170
AC centrifugal blowersdual inlet, Ø 160
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 160 M2E 068-BF
subject to alterations
0 [CFM]
[Pa]
100
200
300
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
A
100 200 300 400
50 100 150 200 250
Step 1
Step 2
Step 3
Step 4
2
4
6
8
1
3
5
7
Curves
1210
1735
910
1345
765
1135
555
835
n[rpm]
P1
[W]I
[A]
108
102
74
71
64
61
50
49
0.47
0.44
0.35
0.34
0.31
0.30
0.26
0.25
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 400 1170 110 0.49 2.5 /400 53 100 -25 to +55
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
51
55
43
48
38
44
30
36
6 45
3 12
171
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: CCC, GOST
Centrifugal blower with flange
D2E 160-FI01 -01
kg
2.5
Connection leadp. 558
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
5 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 3
A 4
A 5
A 6
A 7
A 8
172
AC centrifugal blowersdual inlet, Ø 160
– Material: Housing: PP plastic, black
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 4-step blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 160 M2E 068-CF
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
[in H
2O
]
[m3/h]
60 Hz50 Hz
100
200
300
400
500
0,5
1,0
1,5
2,0
A
Step 1
Step 2
Step 3
Step 4
8
6
4
2
7
5
3
1
Curves
1400
1920
1010
1450
770
1115
500
740
n[rpm]
P1
[W]I
[A]
180
162
120
113
96
93
76
75
0.80
0.70
0.56
0.53
0.46
0.45
0.38
0.37
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 550 1400 180 0.80 4.0 /400 59 150 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
59
60
48
52
40
44
28
34
6 45
3 12
173
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-2-31, CE
– Approvals: CCC, GOST
Centrifugal blower with flange
D2E 160-FK11 -02
kg
3.0
Connection leadp. 558
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
5
N
L1
6
PE
12 3
4
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 926 682-3
6 x plug pin: AMP 926 886-1
1 = Step 1 (min.) white
2 = Step 2 red
3 = Step 3 grey
4 = Step 4 (max.) black
5 = N blue
6 = Protective earth green/yellow
Electrical connection:
When changing speeds,
switch must break the
circuit
Speed
increase
5 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 9
A 10
A 3
A 4
A 5
A 6
A 7
A 8
174
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller: PA plastic, black
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on cable exit
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 5-step blower with integrated terminal box,
EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 146 M4E 068-CF
subject to alterations
100 200 300 400 500
0 100 200 300 [CFM]
[Pa]
20
40
60
80
100
120
0,1
0,2
0,3
[in H
2O
]0
,4
[m3/h]
60 Hz50 Hz
Step 2
Step 3
Step 4
Step 5
Step 1
A
2
4
6
8
10
1
3
5
7
9
Curvesn
[rpm]P1
[W]I
[A]
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 565 780 65 0.29 2.0 /400 46 0 -25 to +501~ 230 60 510 710 68 0.30 2.0 /400 42 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
1080
1345
695
1210
560
1080
450
735
315
475
58
43
52
39
48
40
20
20
13
13
0.25
0.19
0.23
0.18
0.22
0.19
0.16
0.16
0.13
0.13
45
46
33
43
26
39
21
29
17
20
175
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-1, CE
Centrifugal blower with flange
D4E 146-LV19 -14
kg
2.5
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
ce
ntri
fuga
l blo
wer
321
PE
9
L1
N
8 4
5
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 927 231-3
7 x plug pin: AMP 926 886-1
1 = Step 1 (min.)
2 = Step 2
3 = Step 3
4 = Step 4
5 = Step 5 (max.)
8 = N
9 = Protective earth
Electrical connection:
When changing speeds,
switch must break the
circuit
7 8 9
6
54
1 2 3
Speed
increase
4 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
X
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
A 9
A 10
A 3
A 4
A 5
A 6
A 7
A 8
176
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: PP plastic, black
Impeller / motor suspension: PA plastic, black
Rotor: Partially cast in aluminium
Terminal box: PP plastic, black
– Direction of rotation: Counter-clockwise, seen on cable exit
– Type of protection: IP 44
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: 5-step dual blower with integrated terminal box,
standard external-rotor motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
K4E 146 M4E 068-DF
subject to alterations
200 400 600 800 1000
0 200 400 600 [CFM]
[Pa]
20
40
60
80
100
120
0,1
0,2
0,3
[in H
2O
]0
,4
[m3/h]
60 Hz50 Hz
Step 5
Step 4
Step 3
Step 2
Step 1
A
10
8
6
4
2
97
5
3
1
Curves
1050
1240
810
1060
570
820
400
580
330
480
n[rpm]
P1
[W]I
[A]
76
65
59
51
47
43
13
13
10
10
0.33
0.28
0.27
0.24
0.22
0.21
0.15
0.15
0.13
0.13
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C
—1~ 230 50 1180 750 85 0.38 2.5 /450 47 0 -25 to +50
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
nLpA
[dB(A)]
45
46
39
41
29
35
25
28
25
26
177
– Motor protection: TOP wired internally
– Connection leads: Via plug
– Protection class: I
– Capacitor: FPU (P2) integrated in terminal box completely wired up and ready for plug-in
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Dual centrifugal blower with flange
K4E 146-AB73 -21
kg
4.0
Connection leadp. 558
Guard grillep. 556
Capacitorp. 560 f.
Mas
s of
dua
l ce
ntri
fuga
l blo
wer
321
PE
9
L1
N
8 4
5
View X
AMP Universal Mate-N-Lok coded plug system
Connector shell: AMP 927 231-3
7 x plug pin: AMP 926 886-1
1 = Step 1 (min.)
2 = Step 2
3 = Step 3
4 = Step 4
5 = Step 5 (max.)
8 = N
9 = Protective earth
Electrical connection:
When changing speeds,
switch must break the
circuit
3 2 1
4
56
9 8 7
Speed
increase
8 x
sheet metal nut for thread
EN ISO 1478-ST4.8
(min. screw length
14.5 mm plus thickness
of mounting material)
X
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
C 1
C 2
178
AC centrifugal blowersdual inlet, Ø 097
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 20
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 097 M2E 052-BF
subject to alterations
100 200 300 400
0 50 100 150 [CFM]200
[Pa]
50
100
150
200
250
300
0,2
50
,50
,75
[in H
2O
]1
,0
[m3/h]
60 Hz50 Hz
2 2
1 1
1
2
A
B
C
Curves
1670
2080
1490
2000
2150
2475
n[rpm]
P1
[W]I
[A]
27
25
48
44
83
73
0.13
0.12
0.22
0.20
0.37
0.33
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 180 1550 28 0.13 1.0 /400 46 0 -25 to +851~ 230 60 170 1450 32 0.15 1.0 /400 44 0 -25 to +80
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
D2E 097 M2E 052-BF A1)1~ 230 50 300 1350 50 0.23 1.5 /400 50 0 -25 to +701~ 230 60 280 1250 55 0.25 1.5 /400 48 0 -25 to +55
B
D2E 097 M2E 052-CA A1)1~ 230 50 435 1950 87 0.39 2.0 /400 58 0 -25 to +401~ 230 60 410 1850 100 0.45 2.0 /400 57 0 -25 to +35
C
179
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOSTC
Centrifugal blowerwithout flange
D2E 097-CH85 -02
I200
ØH
5,5
A
B
DC E
O
M
PN
1L
K
Dimensions
A B C D E H I K L M N O P
140.0 128.0 78.0 66.0 46.0 80.0 108.0 144.0 76.0 137.0 62.0 96.0 51.0
Centrifugal blowerwith flange
D2E 097-CH85 -48
kg
1.5
D2E 097-BK66 -02 180.0 168.0 100.0 88.0 67.0 79.5 146.0 162.0 86.0 165.0 68.0 114.0 62.5D2E 097-BK66 -48 1.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
D2E 097-BI56 -02 180.0 168.0 100.0 88.0 67.0 79.5 146.0 162.0 86.0 165.0 68.0 114.0 62.5D2E 097-BI56 -48 1.5
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
180
AC centrifugal blowersdual inlet, Ø 133
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, clockwise seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
BA
Nominal data
Type Motor
D2E 133 M2E 068-CF
subject to alterations
200 400 600
0 100 200 300 [CFM]
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1
1
B
A
Curves
2135
2450
1885
2640
n[rpm]
P1
[W]I
[A]
160
138
180
130
0.70
0.61
0.80
0.58
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 700 1700 175 0.77 4.0 /400 58 50 -25 to +401~ 230 60 500 2100 190 0.84 4.0 /400 58 200 -25 to +40
A
D2E 133 M2E 068-DF A1)1~ 230 50 685 1500 190 0.84 3.0 /450 59 0 -25 to +451~ 230 60 510 1800 200 0.88 3.0 /450 56 100 -25 to +40
B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
181
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, also GOSTB
Centrifugal blowerwithout flange
D2E 133-CI33 -56
IJ
Ø11
25,
5
A
B
DC E
145
M
PN
1L
K
Dimensions
A B C D E I J K L M N P
206.0 190.0 142.0 126.0 102.0 168.0 400.0 204.0 97.0 213.0 93.5 67.5
Centrifugal blowerwith flange
D2E 133-CI33 -22
kg
3.3
D2E 133-AM47 -01 254.0 238.0 108.0 92.0 69.0 215.0 300.0 171.5 88.0 180.0 79.0 66.0D2E 133-AM47 -23 3.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
182
AC centrifugal blowersdual inlet, Ø 133
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 133 M2E 068-DF
subject to alterations
200 400 600 800
0 100 200 300 [CFM]400
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1700
2480
n[rpm]
P1
[W]I
[A]
180
138
0.80
0.61
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 810 1150 190 0.84 3.0 /450 56 0 -25 to +401~ 230 60 600 1550 195 0.85 3.0 /450 55 100 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
183
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blowerwithout flange
D2E 133-DM47 -01
232300
Ø11
25,
5
270
254
126
142 10
2
145
21367
,598
1
97
204
Centrifugal blowerwith flange
D2E 133-DM47 -23
kg
4.4
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
184
AC centrifugal blowersdual inlet, Ø 133
– Material: Housing: Galvanised sheet steel
Impeller: PA plastic
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 133 M4E 068-BF
subject to alterations
200 400 500100 300
0 100 200 [CFM]300
[Pa]
40
80
120
140
20
60
100
0,2
[in H
2O
]0
,4
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1240
1380
n[rpm]
P1
[W]I
[A]
66
63
0.30
0.29
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 510 1180 70 0.32 2.0 /400 52 0 -25 to +401~ 230 60 540 1240 80 0.35 2.0 /400 54 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
185
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blowerwithout flange
D4E 133-AH01 -55
215300
Ø11
25,
5
254
238
92108 69
145
180
6676
1
88
171,5
Centrifugal blowerwith flange
D4E 133-AH01 -58
kg
2.6
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
186
AC centrifugal blowersdual inlet, Ø 133
– Material: Housing: Galvanised sheet steel
Impeller: PA plastic
Rotor: Partially cast in aluminium
– Direction of rotation: Clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 133 M4E 068-BF
subject to alterations
200 400 600
0 100 200 400 [CFM]300
[Pa]
40
80
120
160
0,2
0,6
[in H
2O
]0
,4
[m3/h]
60 Hz50 Hz
2
1
A
2
1
B
Curves
1150
1300
1280
1370
n[rpm]
P1
[W]I
[A]
69
65
67
58
0.31
0.30
0.30
0.27
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 670 1080 73 0.33 2.0 /400 52 0 -25 to +401~ 230 60 675 1100 83 0.37 2.0 /400 52 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
D4E 133 M4E 068-CF A1)1~ 230 50 760 1230 75 0.34 2.0 /450 55 0 -25 to +701~ 230 60 790 1280 95 0.43 2.0 /450 56 0 -25 to +60
B
187
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
Centrifugal blowerwithout flange
D4E 133-DH01 -J2
232300
Ø11
25,
5
270
254
126
142 10
2
145
21367
,598
1
97
204
Centrifugal blowerwith flange
D4E 133-DH01 -J4
kg
3.3
D4E 133-DL01 -H9 D4E 133-DL01 -J5 3.8
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
188
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 146 M2E 068-EC
subject to alterations
200 400 600 800 1000
0 100 200 600 [CFM]300 400 500
[Pa]
100
200
300
400
500
600
0,5
1,0
2,0
2,5
[in H
2O
]1
,5
[m3/h]
60 Hz50 Hz
2 2
1
1
A
B
Curves
1935
2560
2300
2600
n[rpm]
P1
[W]I
[A]
230
167
262
206
1.02
0.74
1.15
0.91
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 935 1650 245 1.08 6.0 /400 60 100 -25 to +401~ 230 60 690 2100 270 1.20 6.0 /400 62 250 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
D2E 146 M2E 068-EC A1)1~ 230 50 970 2050 300 1.31 8.0 /400 63 200 -25 to +401~ 230 60 690 2550 330 1.45 8.0/400 68 400 -25 to +35
B
189
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal blowerwithout flange
D2E 146-AP43 -02
232350
Ø11
75,
5
270
254
126
142 10
2
145
219
6998
197
206
Centrifugal blowerwith flange
D2E 146-AP43 -22
kg
4.2
D2E 146-AP47 -02 D2E 146-AP47 -22 4.2
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
190
AC centrifugal blowersdual inlet, Ø 146
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 146 M4E 068-CF
subject to alterations
200 400 600 800
0 100 200 300 [CFM]400
[Pa]
40
80
120
160
0,2
0,4
0,6
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1180
1390
n[rpm]
P1
[W]I
[A]
88
65
0.39
0.29
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 835 1000 100 0.44 2.0 /450 55 0 -25 to +501~ 230 60 765 950 116 0.51 2.0 /450 53 0 -25 to +50
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
191
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blowerwithout flange
D4E 146-AA07 -02
232350
Ø11
75,
5
270
254
126
142 10
2
145
219
6998
197
206
Centrifugal blowerwith flange
D4E 146-AA07 -22
kg
3.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
192
AC centrifugal blowersdual inlet, Ø 160
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: Standard external-rotor motor mounted via brackets on one side
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 160 M4E 068-DF
subject to alterations
200 400 600
0 100 200 300 [CFM]400
[Pa]
40
80
120
160
200
240
0,2
0,4
0,8
[in H
2O
]0
,6
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1230
1360
n[rpm]
P1
[W]I
[A]
114
93
0.50
0.41
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 780 1200 117 0.51 3.0 /450 58 0 -25 to +551~ 230 60 820 1200 140 0.62 3.0 /450 58 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
193
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blowerwithout flange
D4E 160-DA01 -02
176400
Ø13
05,
5
214
198
129
145 10
5
175
242
8710
0,5
1103
226
Centrifugal blowerwith flange
D4E 160-DA01 -22
kg
4.3
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
194
AC centrifugal blowersdual inlet, Ø 160
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 20
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D2E 160 M2E 074-FA
subject to alterations
200 400 600 800 1000 1200
0 150 450 600 [CFM]300
[Pa]
100
200
300
400
500
600
0,5
1,0
1,5
2,5
[in H
2O
]2
,0
[m3/h]
60 Hz50 Hz
2
1
A
Curves
2265
2520
n[rpm]
P1
[W]I
[A]
380
338
1.67
1.50
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 1195 1850 410 1.80 10.0 /400 64 200 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
195
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
Centrifugal blowerwithout flange
D2E 160-AB01 -06
2761300
Ø13
0
175
10287
100,
5
107
241
225
Centrifugal blowerwith flange
—
kg
5.7
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
196
AC centrifugal blowersdual inlet, Ø 160
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 44
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 160 M4E 068-EC
subject to alterations
400 800 1200
0 200 400 600 [CFM]800
[Pa]
50
100
150
200
250
0,2
50
,51
,0[in
H2O
]0
,75
[m3/h]
60 Hz50 Hz
2
1 1
A
B
Curves
1355
1445
1400
1460
n[rpm]
P1
[W]I
[A]
153
100
154
103
0.67
0.43
0.68
0.46
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 1240 1300 180 0.79 5.0 /400 63 0 -25 to +651~ 230 60 1250 1350 245 1.07 5.0 /400 64 10 -25 to +30
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
D4E 160 M4E 068-GA A1)1~ 230 50 1310 1350 185 0.81 6.0 /400 64 0 -25 to +701~ 230 60 1410 1450 270 1.18 6.0 /400 67 0 -25 to +40
B
197
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOST
– Options: With flange
B
Centrifugal blowerwithout flange
D4E 160-EG06 -05
I400
Ø13
0
175
10287
100,
5
107
241
225
Dimensions
I
232.0
Centrifugal blowerwith flange
—
kg
4.5
D4E 160-FH12 -05 276.0— 5.9
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
198
AC centrifugal blowersdual inlet, Ø 180
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4D 180 (1)(2) M4D 068-GA
subject to alterations
400 800 1200 1600 2000
0 200 600 800 [CFM]400 1000 1200
[Pa]
50
100
150
200
250
300
350
1,2
5[in
H2O
]1
,00
0,7
50
,50
0,2
5
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1100
1275
n[rpm]
P1
[W]
260
175
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
C1)/C2)3~ 230/400 50 1880 1050 290 0.92/0.53 — 62 0 -25 to +553~ 230/400 60 1860 1030 360 1.04/0.60 — 62 0 -25 to +30
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, 1 m length) (2) 230 VAC ∆ / 400 VAC Y
I[A]
0.83/0.48
0.56/0.32
199
– Motor protection: Without thermal protection
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blower with flange
—
309
255
289
180
722
4
255
136
600
192
133
296
5˚6x60˚
3,2 333
258
278
Ø14
9
180
Radial blower with flange (large)
D4D 180-CB01 -02
kg
9.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Electr. connectionsp. 596 f.
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
200
AC centrifugal blowersdual inlet, Ø 180
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 180 M4E 068-LA
subject to alterations
400 800 1200 1600 2000
0 200 600 800 [CFM]400 1000 1200
[Pa]
50
100
150
200
250
300
350
1,2
5[in
H2O
]1
,00
0,7
50
,50
0,2
5
[m3/h]
60 Hz50 Hz
2 2
1 1
A
B
Curves
1350
1400
1300
1385
n[rpm]
P1
[W]I
[A]
310
240
360
270
1.36
1.07
1.60
1.20
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 1900 1300 360 1.58 10.0 /400 65 0 -25 to +651~ 230 60 2040 1360 460 2.02 10.0 /400 66 0 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, length 1 m)
D4E 180 (1) M4E 068-LA A1)1~ 230 50 2110 1250 380 1.68 10.0 /400 64 0 -25 to +601~ 230 60 2125 1280 495 2.16 10.0 /400 64 0 -25 to +35
B
201
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, also GOSTA
Centrifugal blower with flange
D4E 180-BA02 -02
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
Dimensions
C D E S
188.0 168.0 134.0 90.0
Centrifugal blowerwith flange (large)
—
kg
11.0
— 278.0 258.0 224.0 180.0D4E 180-CA02 -02 10.8
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
309
255
289
180
7E
255
136
600
192
133
296
5˚6x60˚
3,2 333
DC
Ø14
9
S
Brass lead tips
Hole with large
flange only
B
B 1
B 2
202
AC centrifugal blowersdual inlet, Ø 200
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4D 200 (1)(2) M4D 068-LA
subject to alterations
400 800 1200 1600 2000 2400
0 250 750 1000 [CFM]500 1250
[Pa]
50
100
150
200
250
300
350
400
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
B
2
1
A
Curves
1125
1260
1185
1300
n[rpm]
P1
[W]
425
310
445
350
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
C1)/C2)3~ 230/400 50 2550 1080 480 1.54/0.89 — 63 0 -25 to +30
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, 1 m length) (2) 230 VAC ∆ / 400 VAC Y
D4E 200 (1) M4E 068-LA A1)1~ 230 50 2380 1100 490 2.15 10.0 /400 60 50 -25 to +401~ 230 60 2050 1250 525 2.30 10.0 /400 60 150 -25 to +40
B
I[A]
1.36/0.79
1.00/0.58
1.95
1.55
203
– Motor protection: without TOP, TOP wired internally
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
BA
Centrifugal blower with flange
—
Centrifugal blowerwith flange (large)
D4D 200-CA01 -02
kg
12.0
— D4E 200-CA02 -02 11.9
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
341
287
321
180
725
0
287
151
600
213
146
327
5˚6x60˚
3,2 371
284
304
Ø16
7
180
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
204
AC centrifugal blowersdual inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 22
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4D 225(1)(2) M4D 074-LA
subject to alterations
500 1000 1500 2000 2500 3000
0 500 1000 1500 [CFM]
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
1110
1300
n[rpm]
P1
[W]
600
385
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
C1)/C2)3~ 230/400 50 2980 1000 680 1.99/1.15 — 64 0 -25 to +453~ 230/400 60 2430 1050 700 2.17/1.25 — 62 100 -25 to +35
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, 1 m length) (2) 230 VAC ∆ / 400 VAC Y
I[A]
1.75/1.02
1.13/0.66
205
– Motor protection: Without thermal protection
– Cable exit: Variable
– Protection class: I
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC
Centrifugal blower with flange
—
Centrifugal blowerwith flange (large)
D4D 225-CC01 -02
kg
12.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Electr. connectionsp. 596 f.
341
287
321
180
725
0
287
151
600
242
158
327
5˚6x60˚
3,2 370
284
304
Ø19
4
180
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
B 1
B 2
C 1
C 2
206
AC centrifugal blowersdual inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Partially cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (opposite cable exit)
– Type of protection: IP 22, IP 54
– Insulation class: "B"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
CBA
Nominal data
Type Motor
D4E 225 M4E 074-LA
subject to alterations
500 1000 1500 2000 2500
0 500 1000 [CFM]1500
[Pa]
100
200
300
350
50
150
250
0,5
1,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1
1
1
2
A
B
C
Curves
1200
1370
1170
1300
850
940
n[rpm]
P1
[W]I
[A]
660
480
680
550
330
245
2.88
2.13
2.98
2.44
1.45
1.08
A
A
1
2
VAC Hz m3/h rpm W A µF/VDB dB(A) Pa °C p. 596 f.
A1)1~ 230 50 2600 1100 700 3.05 25.0 /400 67 20 -25 to +40
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Air
flo
w
Spe
ed/r
pm
Pow
er in
put
Cur
rent
dra
w
Cap
acito
r
Sou
nd p
ress
ure
leve
l
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
(1) data collected via exhaust duct (step diffuser, length 1 m)
D4E 225 (1) M4E 074-LA A1)1~ 230 50 2650 1150 650 2.84 25.0 /400 65 100 -25 to +40
B
D6E 225 (1) M6E 068-LA A1)1~ 230 50 2680 800 365 1.60 10.0 /450 59 20 -25 to +401~ 230 60 2480 900 410 1.80 10.0 /450 59 80 -25 to +40
C
207
– Motor protection: TOP wired internally
– Cable exit: Variable
– Protection class: I
– Capacitor: FPU (P2) acc. to IEC 252
– Product conforming to standards: EN 60335-1, CE
– Approvals: CCC, GOSTBBA
BA
Centrifugal blower with flange
D4E 225-BC01 -02
Dimensions
A B C D E F I S
341.0 321.0 200.0 180.0 146.0 287.0 287.0 90.0
Centrifugal blowerwith flange (large)
—
kg
12.1
— 341.0 321.0 304.0 284.0 250.0 287.0 287.0 180.0D4E 225-CC01 -02 12.4
— 387.0 367.0 304.0 284.0 250.0 333.0 333.0 180.0D6E 225-FB07 -02 12.5
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
A
F
B
180
7E
I
151
600
242
158
327
5˚6x60˚
3,2 370
DC
Ø19
4
S
Brass lead tips
Hole with large
flange only
CB
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
208
AC centrifugal blowersdual inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4D 225 M4D 094-LA
subject to alterations
1000 2000 3000 4000
0 500 1000 2000 [CFM]1500 2500
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1 1
A
B
Curves
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
D4D 225 (2) M4D 094-LA
1360
1420
1320
1390
n[rpm]
P1
[W]I
[A]
717
454
877
589
1.50
1.18
1.70
1.31
A
B
A
B
1
2
2
1
LpA
[dB(A)]
69
63
72
65
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
D1)3~ 400 Y 50 1300 950 1.82 — 0 -40 to +853~ 400 Y 60 1350 1320 2.40 — 0 -40 to +40
3~ 400 Y 50 1230 1140 2.10 — 0 -40 to +703~ 400 Y 60 1360 1280 2.30 — 150 -40 to +50
A
D1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
209
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: GOST
– Options: 400 VAC ∆/Y for two speed steps available on request,
mounting brackets on request
A
Centrifugal blower with flange
D4D 225-FH02 -01
Dimensions
C D E S
200.0 180.0 146.0 90.0
Centrifugal blowerwith flange (large)
—
kg
15.6
— 304.0 284.0 250.0 180.0D4D 225-GH02 -01 15.6
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Electr. connectionsp. 596 f.
387
333
367
180
7E
333
151
600
242
158
327
5˚6x60˚
3,2 370
DC
Ø19
4
S
Brass lead tips
Hole with large
flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
210
AC centrifugal blowersdual inlet, Ø 225
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 225 M4E 094-LA
subject to alterations
1000 2000 3000 4000
0 500 1000 2000 [CFM]1500 2500
[Pa]
100
200
300
400
500
0,5
1,0
1,5
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1 1
A
B
Curves
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
D4E 225 (2) M4E 094-LA
1330
1410
1270
1380
n[rpm]
P1
[W]I
[A]
802
530
947
652
4.16
3.08
4.81
3.52
A
B
A
B
1
2
2
1
LpA
[dB(A)]
69
63
71
65
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1230 1060 5.38 10.0 /450 0 -40 to +551~ 230 60 1410 1085 5.24 10.0 /500 200 -40 to +45
1~ 230 50 1230 1060 5.38 10.0 /450 100 -40 to +551~ 230 60 1370 1120 5.40 10.0 /500 250 -40 to +45
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
211
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: GOST
– Options: Mounting brackets on request
A
Centrifugal blower with flange
D4E 225-EH01 -01
Dimensions
C D E S
200.0 180.0 146.0 90.0
Centrifugal blowerwith flange (large)
—
kg
16.7
— 304.0 284.0 250.0 180.0D4E 225-DH01 -01 16.7
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
387
333
367
180
7E
333
151
600
242
158
327
5˚6x60˚
3,2 370
DC
Ø19
4
S
Brass lead tips
Hole with large
flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
212
AC centrifugal blowersdual inlet, Ø 240
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 240 M4E 094-IF
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM]1500 2000 2500
[Pa]
100
200
300
400
500
0,5
1,0
1,5
2,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
2
1
A
Curves
(1) Nominal data in operating point with maximum load
1345
1390
n[rpm]
P1
[W]I
[A]
849
692
3.80
3.10
A
A
1
2
LpA
[dB(A)]
73
70
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1300 1020 4.45 25.0 /400 0 -40 to +501~ 230 60 1310 1320 5.75 25.0 /400 50 -40 to +55
A
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
213
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Options: Mounting brackets on request
Centrifugal blower with flange
D4E 240-BA01 -01
Centrifugal blowerwith flange (large)
—
kg
15.3
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
341
287
321
180
714
6
287
151
600
242
158
327
5˚
3x120˚
370
180
200
Ø20
9
90
Brass lead tips
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
214
AC centrifugal blowersdual inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4D 250 M4D 094-LA
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM]1500 2000 2500
[Pa]
100
200
300
400
500
0,5
1,0
1,5
2,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
1 1
A
B
Curves
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
D4D 250 (2) M4D 094-LA
1320
1410
1280
1370
n[rpm]
P1
[W]I
[A]
875
481
1001
675
1.73
1.21
1.89
1.43
A
B
A
B
1
2
2
1
LpA
[dB(A)]
71
65
72
69
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
D1)3~ 400 Y 50 1240 1140 2.10 — 0 -40 to +603~ 400 Y 60 1410 1210 2.20 — 250 -40 to +45
3~ 400 Y 50 1200 1270 2.30 — 50 -40 to +453~ 400 Y 60 1410 1270 2.20 — 350 -40 to +45
A
D1)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
215
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Options: 400 VAC ∆/Y for two speed steps available on request,
mounting brackets on request
Centrifugal blower with flange
D4D 250-BA02 -01
328
3,2
387
275
194
6x60˚
173
392
Ø20
0
UC D
600
S
298
180
329
298
349
E7
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
Centrifugal blowerwith flange (large)
—
kg
16.7
— 313.0 285.0 262.0 180.0 293.0D4D 250-CA02 -01 16.7
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Electr. connectionsp. 596 f.
Brass lead tips
Hole with large
flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
216
AC centrifugal blowersdual inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D4E 250 M4E 094-LA
subject to alterations
1000 2000 3000 4000
0 500 1000 [CFM]1500 2000 2500
[Pa]
100
200
300
400
500
0,5
1,0
1,5
2,0
[in H
2O
]
[m3/h]
60 Hz50 Hz
2 2
11
A
B
Curves
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
D4E 250 (2) M4E 094-LA
1320
1400
1270
1370
n[rpm]
P1
[W]I
[A]
975
665
1100
788
4.74
3.50
5.31
3.94
A
B
A
B
1
2
2
1
LpA
[dB(A)]
71
65
72
69
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 1210 1240 6.00 14.0 /500 0 -40 to +401~ 230 60 1460 1230 5.54 14.0 /500 300 -40 to +45
1~ 230 50 1200 1250 6.00 14.0 /500 100 -40 to +401~ 230 60 1400 1285 5.90 14.0 /500 350 -40 to +40
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
217
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Approvals: GOST
– Options: Mounting brackets on request
B
Centrifugal blower with flange
D4E 250-BA01 -01
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
Centrifugal blowerwith flange (large)
—
kg
16.3
— 313.0 285.0 262.0 180.0 293.0D4E 250-CA01 -01 16.3
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
328
3,2
387
275
194
6x60˚
173
392
Ø20
0
UC D
600
S
298
180
329
298
349
E7
Brass lead tips
Hole with large
flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts
218
AC centrifugal blowersdual inlet, Ø 250
– Material: Housing: Galvanised sheet steel
Impeller: Galvanised sheet steel
Rotor: Cast in aluminium
– Direction of rotation: Counter-clockwise, seen on rotor (on cable exit)
– Type of protection: IP 20 (acc. to EN 60527)
– Insulation class: "F"
– Mounting position: Any
– Condensate discharges: None
– Mode of operation: Continuous operation (S1)
– Design: EW motor anti-vibration mounted on both sides
– Bearings: Maintenance-free ball bearings
Nominal data
Type Motor
D6E 250 M6E 094-HA
subject to alterations
800 1600 2400 2800400 1200 2000
0 400 800 1200 [CFM]1600
[Pa]
50
100
150
200
250
0,2
50
,51
,0[in
H2O
]0
,75
[m3/h]
60 Hz50 Hz
1 1
22
A
B
Curves
(1) Nominal data in operating point with maximum load (2) Data collected via exhaust duct (step diffuser, 1 m length)
D6E 250 (2) M6E 094-HA
890
940
830
900
n[rpm]
P1
[W]I
[A]
318
244
375
304
1.51
1.25
1.74
1.45
A
B
A
B
1
2
2
1
LpA
[dB(A)]
59
53
65
57
VAC Hz rpm W A µF/VDB Pa °C p. 596 f.
A2a)1~ 230 50 800 400 1.85 10.0 /400 0 -40 to +801~ 230 60 770 480 2.15 10.0 /450 0 -40 to +80
1~ 230 50 680 470 2.20 10.0 /400 0 -40 to +701~ 230 60 580 500 2.30 10.0 /450 0 -40 to +55
A
A2a)B
Cur
ve
Nom
inal
vol
tage
Freq
uenc
y
Spe
ed/r
pm(1
)
Cap
acito
r
Min
.bac
k pr
essu
re
Perm
.am
b.te
mp.
Elec
tr.c
onne
ctio
n
Max
.pow
er
inpu
t(1
)
Max
.cur
rent
dr
aw(1
)
219
– Motor protection: Design with thermal overload protector
– Cable exit: Axial
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standard: CE
– Options: Mounting brackets on request
Centrifugal blower with flange
D6E 250-BA01 -01
Dimensions
C D E S U
218.0 190.0 167.0 90.0 198.0
Centrifugal blowerwith flange (large)
—
kg
14.4
— 313.0 285.0 262.0 180.0 293.0D6E 250-CA01 -01 14.4
Mas
s of
ce
ntri
fuga
l blo
wer
Guard grillep. 555
Capacitorp. 560 f.
Electr. connectionsp. 596 f.
328
3,2
387
275
194
6x60˚
173
392
Ø20
0
UC D
600
S
298
180
329
298
349
E7
Brass lead tips
Hole with large
flange only
B
Gen
era
l in
form
ati
on
AC
cen
trif
ug
al,
ba
ck
wa
rdA
C c
en
trif
ug
al,
forw
ard
EC
cen
trif
ug
al,
ba
ck
wa
rdE
C c
en
trif
ug
al,
ba
ck
-w
ard
fo
r cl
ea
n r
oo
ms
EC
cen
trif
ug
al,
forw
ard
EC
-SY
ST
EM
SA
ccess
ori
es
Tech
no
log
yC
on
tacts