8-The GINA, Groeneveld TWIN

18
Workshop manual TWIN greasing system EM1701D1.DOC Operation B - 15 THE GINA TWIN GREASING SYSTEM 1 INTRODUCTION The GINA (Groeneveld tester for INstallation and Analysis) is a programming and read-out device for the digi- tal control unit of the TWIN greasing system. In the description that follows all screens of the GINA are dealt with in the order in which they have been placed in its menu system. Toget aquainted with the menu system and the features the GINA offers, we advise you to follow the sequence as presented, if only once. In practise there is, of course, no reason whatsoever for such a rigid and time consuming approach. Normally, you would go directly to the screen that contains the in- formation you want to view or the settings you wish to change. The read-outs and setting have been grouped in three menus: main menu parameters timer diagnosis menu. You can access each of these menu’s by pressing MAIN , PARAMETERS or DIAGNOSIS on the keypad op the GINA. You can do so at any time, regardless of the screen currently shown on the display. Some screens just show information. You cannot change anything in those screens. Other screens allow you to change parameters or the status of a particular input or output. You can recognise those screen by the blinking cursor that appears on them (with the exception of the system configuration and error-logging-reset screens). A number of screens show the current time in their top-right corner. In the screens, as reproduced in this man- ual, this is indicated by hh:mm:ss. Values are usually denoted to by a number of x-signs, with one ‘x’ for every possible digit in the number. 2 PREPARATIONS 2.1 Control pad Besides a 4-line display, the GINA features they following keys: key function POWER ON/OFF To turn the GINA on or off (toggle). F1 ... F4 (softkeys) To make a particular choice in a menu. 0 ... 9 To enter numerical data. MAIN To call the main menu (to view miscellaneous information) PARAMETERS To call the parameter timer menu (to view and enter parameter data) DIAGNOSIS To call the diagnosis menu (to view various system data) NEXT To go to the next screen in the menu system. ENTER To confirm a setting you have changed or entered.

description

Manual de servicio de sistema de engrase automático Groeneveld TWIN

Transcript of 8-The GINA, Groeneveld TWIN

Page 1: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 15

THE GINATWIN GREASING SYSTEM

1 INTRODUCTIONThe GINA (Groeneveld tester for INstallation and Analysis) is a programming and read-out device for the digi-tal control unit of the TWIN greasing system.

In the description that follows all screens of the GINA are dealt with in the order in which they have beenplaced in its menu system. Toget aquainted with the menu system and the features the GINA offers, we adviseyou to follow the sequence as presented, if only once. In practise there is, of course, no reason whatsoever forsuch a rigid and time consuming approach. Normally, you would go directly to the screen that contains the in-formation you want to view or the settings you wish to change.

The read-outs and setting have been grouped in three menus:

main menuparameters timerdiagnosis menu .

You can access each of these menu’s by pressing MAIN, PARAMETERS or DIAGNOSIS on the keypad op the GINA.You can do so at any time, regardless of the screen currently shown on the display.

Some screens just show information. You cannot change anything in those screens. Other screens allow you tochange parameters or the status of a particular input or output. You can recognise those screen by the blinkingcursor that appears on them (with the exception of the system configuration and error-logging-reset screens).A number of screens show the current time in their top-right corner. In the screens, as reproduced in this man-ual, this is indicated by hh:mm:ss. Values are usually denoted to by a number of x-signs, with one ‘x’ for everypossible digit in the number.

2 PREPARATIONS2.1 Control padBesides a 4-line display, the GINA features they following keys:

key function

POWER ON/OFF To turn the GINA on or off (toggle).

F1 ... F4 (softkeys) To make a particular choice in a menu.

0 ... 9 To enter numerical data.

MAIN To call the main menu (to view miscellaneous information)

PARAMETERS To call the parameter timer menu (to view and enter parameter data)

DIAGNOSIS To call the diagnosis menu (to view various system data)

NEXT To go to the next screen in the menu system.

ENTER To confirm a setting you have changed or entered.

Page 2: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 16 Operation

2.2 Connecting the GINAThe supply voltage of the control unit to be read or programmed must be available (from the vehicle or an ex-ternal power supply, if need be).

Connect the GINA with the control unit with the supplied interconnection cable.

Remark:While the GINA is connected to the control unit, the mode-selection switch on the dashboard (if present) of thevehicle cannot be used to change the greasing system’s operating mode.

2.3 Switching onThe GINA can be switched-on after,

1. the GINA has been connected with the control unit, and2. the power supply has been available to the control unit for at

least 8 seconds.

Press POWER ON/OFF and wait about 5 seconds for the GINA to ini-tialise itself.

You can access the main , parameters timer and diagnosis menus bypressing respectively MAIN , PARAMETERS or DIAGNOSIS .Each of those menus are described separately in the chapters 5, 6and 8.

This message appears in the GINA is unable to communicate withthe control unit.

This can be caused by:

� Bad connection (wire in cable broken or a bad connector)� GINA switched on to quickly.� Supply voltage too low

Always try to alleviate the problem by turning the GINA off andthen on again, or by pressing one of the softkeys (F1 ...F4).

This message appears if the control unit is not supported by thisGINA. You need another GINA to access this control unit.

����

����� ��� ��� ���

������������� ������

������ ��� ���������

�������������

� ��� !"

Page 3: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 17

3 THE MENU SYSTEM

3.1 Main menuThe main menu contains various data about the GINA and the con-trol unit that is connected. You change only some of the data.

Press MAIN

Press F1 (info).

The screen shows the identification number of the person whomost recently connected a GINA to this control unit. Attention:This number is overwritten, when the GINA is switched-off.

Press F2 (d-ac).

The screen shows the date and time at which a GINA has, most re-cently, been connected with this control unit. Attention: this dateand time are updated when you switch-off the GINA.

Press F3 (u-ch).

The screen shows the identification number of the person who,most recently, changed any settings of this control unit. Attention:This number will be overwritten when you switch-off the GINA,provided you have changed at least one setting.

Press F4 (d-ch ).

The screen shows the date and time at which the settings of thiscontrol unit were most recently changed. Attention: This time anddate will be overwritten when you switch-off the GINA, providedyou have changed at least one setting.

Press NEXT.

The display shows the version number of the software in theGINA.

Press F2 (p-ui )

�������������� � #$%&�' (((((()*# +*# )*#$ +*#$

�������� ",�-+ �. � #$%&�((*((*(( (('((

)*# +*# )*#$ +*#$

����������� !�� /���"�%0��& )%" ' ((((0*� 0*)" ##��

���� �������� ����

"%�� ",� #�% �

�������������� � ##���' (((((()*# +*# )*#$ +*#$

���������",�-+ �. � ##���((*((*(( (('(()*# +*# )*#$ +*#$

Page 4: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 18 Operation

The display shows the identification number of the registered userof this GINA.

Press F3. (access )

The display shows the access level for all control units that aresupported by this GINA. (you cannot change access levels).

Press NEXT

The screen shows the version number of the software in the GINA.

Press NEXT.

The screen shows the version number of the display texts in thesoftware of this GINA.

Press MAIN to return to the main menu .

Press F2 (time ).

The screen shows the hours of the current day and time. You canchange this setting with the numeric keys. Confirm the new settingwith ENTER.

Press F2 (min ).

The display shows the minutes of the current date and time. Youcan change this setting with the numeric keys. Confirm the newsetting with ENTER. As soon as you press ENTER , the seconds willstart running at zero.

Press NEXT.

The display shows the day of the month of the current day andtime. You cannot change this.

Press F2 (mnth ).

��������)�����0��& )%" ' ((((0*� 0*)" ##��

��������) $��"� "�% �/� ((( 1+�/"#� (2 +3 +4 ���� ����

�������� ��� /���' (((((((((

���� �������� ����

"%�� ",� #�% �

���������% �� $�)��((

$�� ,"%

���������% �� ,"%) ��((

$�� ,"%

���������% �� +�((

+� ,% $ ���

����������� !�� /���"�%0��& )%" ' ((((0*� 0*)" ##��

Page 5: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 19

The display shows the month of the current day and time. Youcannot change this.

Press F3 (year).

The display shows the year of the current date and time. You can-not change this.

Press MAIN to return to the main menu .

Press F3 (contr ).

The contrast of the display may be increased or decreased in thisscreen.

Press F1 (-) to lower the contrast or F4 (+) to raise it. Press the keysuntil you are satisfied with the contrast setting.

3.2 Parameters timer

The parameters timer menu contains the parameter settings for thegreasing cycle. You can view and/or change these parameters (pro-vided you have the correct ‘access level’.

Press PARAMETERS .

The display shows the duration (in minutes) of the greasing cycleas set for the heavy-duty mode. You can change the value with thenumeric keys. The cursor indicates the digit about to be changed,and automatically moves along one digit when a digit is entered.

If the value shown is OK: press ENTER to confirm it. The cursorthen disappears from the display.

Press F2 (ndcy).

���������% �� ,�% $((

+� ,% $ ���

���� �������� ����

"%�� ",� #�% �

���� �������� ����

+5)� #�% �� * 6

���������� ����������� ���������$�/�*+) � #�# �(((( 1,"%) ��2

$+#� %+#� +#� #,�

���������% �� ���((

+� ,% $ ���

Page 6: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 20 Operation

The display shows the duration (in minutes) of the greasing cyclein normal-duty mode.

If necessary, change this value (confirm with ENTER).

Press F3 (ldcy).

The display shows the duration of the greasing cycle (in minutes)in light-duty mode.

If necessary, change this value (confirm with ENTER).

Press F4 (cms ).

The display shows which operating mode is currently active:

0 (disabled) The operating mode cannot be set by the driver oroperator. The normal-duty mode is used by default.

1 heavy-duty mode (short greasing cycle)2 normal-duty mode (normal greasing cycle)3 light-duty mode (long greasing cycle)

Press NEXT.

The display shows the maximum duration of the pump phase of agreasing cycle (in minutes).

If necessary, change this value (confirm with ENTER).

Press F2 (vmf ).

The display shows the factor with which the actual duration of apump phase is to be multiplied to calculate the required duration ofthe pressure-relief phaseThe value shown on the display must be divided by 10 to obtain the actual factor.

If necessary, change this value (confirm with ENTER).

Press F3 (noa).

���������� ����������� ���������%��, *+) � #�# �(((( 1,"%) ��2

$+#� %+#� +#� #,�

���������� ����������� ��������� �!*+) � #�# �(((( 1,"%) ��2

$+#� %+#� +#� #,�

���������� ����������� ���������#�# � ,�+� �� �# (' 78+"� 98$+ :8%+ ;8 +

$+#� %+#� +#� #,�

���������� ����������� ���������,(",), 0),0 ",�((( 1,"%) ��2

,0 /,� %� <#+#

���������� ����������� ���������/�% ,) "0 � �# ��((( 1=972

,0 /,� %� <#+#

Page 7: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 21

The display shows the maximum number of consecutive greasingcycles, in which the required greasing pressure was not attained,that can be allowed (after which the pump and 5/2 valve must bedisabled to prevent damage, and the signal light continuously lit)

The incorrectly executed greasing cycles that are counted are: cycle ‘A’ and ‘B’ (ABABA or BABAB), or cycle ‘A’ or ‘B’ (AAAAA or BBBBB).

If necessary, change this value (confirm with ENTER).

Press F4 (bcdc).

The display shows the number of times the blinking-code for theoperating mode will be repeated by the signal light when the con-tact is switched-on.

If necessary, change this value (confirm with ENTER).

3.3 Diagnosis menuThe diagnosis menu contains various bits of information about thegreasing system’s status, like error messages and the status of theinputs and outputs of the control unit.

Press DIAGNOSIS .

Press F1 (err).

In the displays that follow, various counters are shown. Thesecounters register the number times particular faults occurred in thesystem since it was installed.

Press F1 (tote ).

The display shows the number of greasing cycles in primary greaseline A, during which the grease-pressure switch was not activated(low to high).

Press F2 (npcb ).

The display shows the number of greasing cycles in primary greaseline B, during which the grease-pressure switch was not activated(low to high).

Press F3 (pbcy ).

���������� ����������� ���������%),<�� �� �,0 �(((

,0 /,� %� <#+#

���������� ����������� ���������< "%� #�+� +) � #�# �(

,0 /,� %� <#+#

��������� ����������� ������

��� �=� /� "%��

����������������������� ������ ����

� � 0%+� ,�"�

����� ����������� ������%� 0���� #$%& "%� �(((((

%0# %0#< 0<#�

����� ����������� ������%� 0���� #$%& "%� >(((((

%0# %0#< 0<#�

Page 8: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 22 Operation

The display shows the number of times the contact of the grease-pressure switch was still closed at the start of a pump phase.

Press NEXT.

The display shows the number of times a short-circuit was detectedin the pump motor circuit.

Press F2 (pol ).

The display shows the number of times an interruption was de-tected in the pump motor circuit.

Press F3 (lsc ).

The display shows the number of times a short-circuit was detectedin the signal light circuit.

Press F4 (lol ).

The display shows the number of times an interruption was de-tected in the signal light circuit.

Press NEXT.

The display shows the number of times a short-circuit was detectedin the circuit of the 5/2 solenoid valve.

Press F2 (vol ).

The display shows the total number of greasing cycles in which aninterruption was detected in the 5/2 solenoid valve circuit.

Press F3 (lowl).

The display shows the total number of greasing cycles in which theminimum-level switch has reported a low grease level in the reser-voir

Press F4 (eres).

����� ����������� ������0���� <����� #�# �(((((

%0# %0#< 0<#�

����� ����������� ������0),0 �$�� #"�#)" (((((

0�# 0� �# �

����� ����������� ������0),0 �0�% �+(((((

0�# 0� �# �

����� ����������� ������ ,0 �$�� #"�#)" (((((

0�# 0� �# �

����� ����������� ������ ,0 �0�% �+(((((

0�# 0� �# �

����� ����������� ������/ /� �$�� #"�#)" (((((

/�# /� �! ����

����� ����������� ������/ /� �0�% �+(((((

/�# /� �! ����

����� ����������� ������ �! �/� (((((

/�# /� �! ����

Page 9: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 23

The display shows the total number or greasing cycles in which theminimum-level switch has reported that the reservoir needs to berefilled, and the maximum pump time was reached (because therequired grease pressure was not reached, as signalled by thegrease pressure switch).

Press NEXT.

Press F2 (pnde ).

In the displays that follow, the numbers of pending errors areshown. These are currently active failures. The counters are incre-mented each time the failure occurs, but set to zero if the failuredid not occur during a subsequent greasing cycle.

After the last display of the pending errors has been shown: PressNEXT.

Press F3 (meis ).

In the displays that follow, the maximum number of times particu-lar failures have occurred in consecutive greasing cycles areshown. The values are overwritten only it a new sequence of fail-ures is larger than the preceding one (for that particular fault).

After the last display with 'maximum errors in succession’ has beenshown: Press NEXT.

Press NEXT .Which brings you back to the diagnosis menu .

Press F2 (I/O).

����� ����������� �������,0 � �����/�"�(((((

/�# /� �! ����

����������������������� ������ ����

� � 0%+� ,�"�

��������� ����������� ������

��� �=� /� "%��

Page 10: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 24 Operation

The display shows the current status of the greasing system:

0 auto the system is in its normal operating condition.1 man the system is controlled by hand (with the GINA).2 sngl the system is busy performing a single-cycle test.3 mult the system is busy performing a multiple-cycle test.

You can change the current status of the system by pressing either 0 , 1 , 2 or 3 and confirming that action with ENTER.

Note1: You cannot initiate a test cycle if the system is busy with apump phase.

Note 2: The status will automatically return to 0 (auto) when thecontact is switched-off.

Press NEXT.

This is the first I/O-display. The status of the various inputs andoutputs of the control unit are shown.

An input or output can be either ‘low’ (0) or ‘high’ (1) (‘False’ or‘True’).

pump the electric motor of the pump runs.vlve the 5/2 solenoid valve is actuated.lamp the signal light is litpress the contact of the grease-pressure switch is closed.

The status of the outputs can be changed by pressing F1, F2 or F3 .This either starts or stops the pump, activates or deactivates thesolenoid valve, or lights or extinguishes the signal light.

Note: You can only do this if you have set the system’s status to‘1’ (manual) in the previous display.

Press NEXT.

���=�������=���� ",�� ,�+�' 7) �(' 98,% :8�%& ;8,)

,�+�

���=�������=�����=� �9�( ( ( (

0),0 / /� ,0 0����

Page 11: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 25

This is the second I/O-display:

An input or output can be either ‘low’ (0) or ‘high’ (1) (‘False’ or‘True’).

pol (pump open load) interruption in the pump circuit. This in-dicator is valid only when the pump in not running.

vol (valve open load) interruption in the solenoid valve circuit.This indicator is valid only when the valve is not actuated.

lol (lamp open load) interruption in the signal light circuit.This indicator is valid only if the light is not lit.

gbsw (gear box switch) The supply voltage to the greasing sys-tem has been enabled via an extra switch (to start thegreasing program).

Press NEXT.

This is the third I/O-display:

An input or output can be either ‘low’ (0) or ‘high’ (1) (‘False’ or‘True’).

lowl (low level) the contact of the minimum-level switch in thereservoir is closed.

test the test pushbutton on the pump unit is being depressed.spr (spare)

Press NEXT.

This is the fourth I/O-display:

An input or output can be either ‘low’ (0) or ‘high’ (1) (‘False’ or‘True’).

psc (pump short circuit) short-circuit in the pump circuit.vsc (valve short circuit) short-circuit in the solenoid valve cir-

cuit.lsc (lamp short circuit) short circuit in the signal light circuit.spr (spare).

���=�������=�����=� �:�( ( ( (

0� /� � &<�!

���=�������=�����=� �;�( ( ( (

�! �� �0� �0�

���=�������=�����=� �?�( ( ( (

0�# /�# �# �0�

Page 12: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 26 Operation

Press DIAGNOSIS .

Press F3 (var).

The display shows the remaining time (of the current greasing cy-cle) to the pump phase of the next greasing cycle.

Press F2 (pintv ).

The display shows in which phase of the greasing cycle the greas-ing system currently is.

2 pump phase, cycle A3 pressure-retaining phase, cycle A4 pressure-relieving phase, cycle A29 pause phase, cycle, A32 pump phase, cycle B33 pressure-retaining phase, cycle B34 pressure-relieving phase, cycle B59 pause phase, cycle, B

Press F3 (lpt ).

The display shows the duration of the last pump phase (in sec-onds).

Press NEXT.

Press F4 (tinfo ).

Press F1 (pdif).

The display shows the part number of this control unit.

Press F2 (srno ).

��������� ����������� ������

��� �=� /� "%��

�����>��������>��� $$',,'����,"%"%& #�# � ",�((((( 1,"%) ��2

�# 0"% / 0

�����>��������>��� $$',,'��0��&�, "% ��/ ((

�# 0"% / 0

�����>��������>��� $$',,'�� � 0),0"%& ",�((((( 1��#�%+�2

�# 0"% / 0

��������� ����������� ������

��� �=� /� "%��

������������������

0+"� $"�

���������� ����������� �������0� %),<��(((((

0�%� ��%� "/�

Page 13: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 27

The display shows the serial number of this control unit.

Press F3 (tive ).

The display shows the configuration (a number) of the control unit,concerning the software, the hardware and the components used.

Press NEXT.

Press F2 (hist ).

The display shows the number of running hours, so far, of thepump.

Press F2 (tot ).

The display shows the number of hours the control unit has beenup and running. (the time the supply voltage was present on pin 3of the connector of the control unit).

Press F3 (tcy ).

The display shows the number of greasing cycles the system hasperformed since it was installed.

Press F4 (teewr ).

The display shows the number of times the EEPROM in the con-trol unit was overwritten (data/parameters changed and stored).

All displays have now been shown. If you are satisfied with allsettings, you can switch off the GINA.

Press POWER ON/OFF.

Remove the interconnection cable from the GINA and the controlunit.

���������� ����������� ����������" %),<��(((((((((((

0�%� ��%� "/�

���������� ����������� ������� ",�� /���"�%(((

0�%� ��%� "/�

������������������

0+"� $"�

@�����A@�����A � 0),0"%& ",�(((((( 1$�)��2

0 � #� ��!�

@�����A@�����A � �0�� "%& ",�(((((( 1$�)��2

0 � #� ��!�

@�����A@�����A � #�# ��((((((((((

0 � #� ��!�

@�����A@�����A � ������ !�" ��((((((((

0 � #� ��!�

Page 14: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 28 Operation

4 STRUCTURE OF THE MENU SYSTEM

4.1 Abbreviations

- minus (decrease display contrast)+ plus (increase display contrast)

access authorisation level

bcdc blink code duty cycle (the number of times the start-up blink code will be repeated)

cms cycle mode select (selection of the operating mode)contr contrast (setting the display contrast)

d-ac time & date, last accessd-ch time & date, last changeday day (of the week)eres empty reservoirerr errors

gbsw gear box switch (extra program activation switch)

hdcy heavy-duty cycle (operating mode with short greasing cycle)hist historic (data)hrs hours (time)

I/O inputs/outputsinfo information (about the GINA)inp/outp inputs/outputs

lamp lamp (signal light)ldcy low-duty cycle (operating mode with long greasing cycle)lol lamp open load (interruption in signal light circuit)lowl low level switch (minimum-level switch)lpt last pumping time (duration of last pump phase)lsc lamp short circuit

meis maximum number of errors in successionmin minutes (time setting)mode mode (operating mode)month month (date)mpt maximum pumping time (maximum duration of the pump phase)

ndcy normal-duty cycle (operating mode with greasing cycle of default duration)noa number of attempts (until pump and 5/2 valve are disengaged by the control unit)npca no pressure change line Anpcb no pressure change line B

p-s software-version programmer unit (GINA)p-ui user id programmer unit (GINA)

Page 15: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 29

pbcy pressure before cycle (pressure not relieved before next pump cycle)pintv program interval (status of current greasing cycle)pnde pending errors (active malfunctions)pol pump open load (interruption in pump circuit)press pressure switch (grease-pressure switch)prno part number (part number of the control unit)psc pump short circuit (short circuit in the pump circuit)pump pump

rct remaining cycle time (time until the next pump phase)

spr sparesrno serial number

tcy total cycles (total number of greasing cycles performed so far)teewr total EEPROM writes (total number of times parameters or settings have been changed)test test switch (test pushbutton on the pump unit)text version text version software GINA (the version number of the display texts programmed in the GINAtime time (the current time)tinfo timer information (information about the control unit)tive timer version (information about the configuration of the control unit)tote total errors (the total number of malfunctions detected)tot total operating time (the total time that the system has, so far, been in operation)put total pumping time (The sum of all pump phases, so far).

u-ac user id, last access (Identification of the user who last accessed this control unit)u-ch user id, last change (identification of the user who last changed settings)

var variablesvlve valve (5/2 solenoid valve)vmf venting multiply factor (multiplication factor to calculate the relief-phase)vol valve open load (interruption in the solenoid valve circuit)vsc valve short circuit (short-circuit in the solenoid valve circuit)

year year

Page 16: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 30 Operation

4.2 The main menu

� = NEXT

4.3 The parameters menu

� = NEXT

PARAMETERS

hdcyndcyldcycms

mptvmfnoabcdc

info time contr

hrsmin

u-acd-acu-chd-ch

-+

p-sp-ui

acces

daymnthyear

MAIN

Page 17: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

Operation B - 31

4.4 The diagnosis menu

� = NEXT

DIAGNOSIS

var I/O err tinfo

pdiff hist

pumpvlvelamppress

mode

polvollol

gbsw

tcytoltpt

teewr

prnosrnotive

rctpintvlpt

lowltestsprspr

pscvsclscspr

tote pnde meis

npcanpcbpbcy

pscpollsclol

vscvollowleres

pendingerrors

errorcounters

Page 18: 8-The GINA, Groeneveld TWIN

Workshop manualTWIN greasing system

EM1701D1.DOC

B - 32 Operation