EMERGENCY FIXTURE LEGEND
EXIT SIGN
EXIT SIGN WITH EGRESS LIGHTS
EMERGENCY EGRESS LIGHTS
MISCELLANEOUS LEGEND
MOTOR - PROVIDED BY OTHERS
SWITCH
SPEAKER - CEILING MOUNTED
PHOTOCELL
ABOVE FINISHED FLOORAFF
WEATHERPROOFWP
GROUND FAULT CIRCUIT INTERRUPTERGFI
FIRE ALARM CONTROL PANELFACP
MOTOR CONTROL CENTERMCC
TO BE REMOVEDTBR
NIGHT LIGHTNL
ARC FAULT BREAKERAF
SPEAKER - WALL MOUNTED
DAYLIGHT SENSOR SWITCH
TIMER SWITCH
a - SWITCH DESIGNATION
DIMMER CONTROL - WALL MOUNTED
3 - THREE-WAY SWITCH
CARBON MONOXIDE DETECTOR
TELEPHONE/DATA LEGEND
TELEPHONE OUTLET
TELEPHONE/DATA OUTLET
DATA OUTLET
TELEVISION OUTLET - COAX CONNECTION
ELECTRICAL POWER LEGEND
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE - ABOVE COUNTER OR HIGHER
QUADPLEX RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
J-BOX
DISCONNECT SWITCH - NON-FUSED
COMBINATION STARTER/DISCONNECT SWITCH
RECEPTACLE SYMBOL
9b SWITCH DESIGNATION (IF USED)
CIRCUIT NUMBER
WEATHERPROOFWP
ABOVE COUNTERAC
TYPICAL RECEPTACLE MARKINGS
GROUND FAULT CIRCUIT INTERUPTERGFI
DUPLEX RECEPTACLE - CEILING, RECESSED
DUPLEX RECEPTACLE - FLOOR, RECESSED
ELECTRIC PANEL
FIRE ALARM LEGEND
FIRE ALARM FLOW SWITCH
FIRE ALARM TAMPER SWITCH
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATION PANEL
DISCONNECT SWITCH - FUSED
LIGHT FIXTURES LEGEND
2' x 4' FLUORESCENT OR LED - LAY-IN
2' x 4' FLUORESCENT, PARABOLIC - LAY-IN
WALL MOUNTED LIGHT
DOWNLIGHT - RECESSED
1' x 4' FLUORESCENT OR LED - SURFACE MOUNTED
FLUORESCENT OR LED - UTILITY
FLUORESCENT OR LED - PENDANT HUNG
LIGHT FIXTURE SYMBOL
X
9b
FIXTURE MARK NUMBER
SWITCH DESIGNATION (IF USED)
CIRCUIT NUMBER
TYPICAL LIGHT FIXTURE MARKINGS
SURFACE MOUNTED
PENDANT
2' x 4' FLUORESCENT OR LED, DIRECT/INDIRECT - LAY-IN
2' x 2' FLUORESCENT OR LED, PRISMATIC - LAY-IN
DENOTES UNSWITCHED NIGHT LIGHT
LIGHT FIXTURE W/EMERGENCY BALLAST
NIGHT LIGHT
TRACK LIGHTING
MAIN DISTRIBUTION PANELMDP
AUTOMATIC TRANSFER SWITCHATS
MANUAL TRANSFER SWITCHMTS
TELEPHONE TERMINAL BOARDTTB
DOOR HOLD OPENER
PROVIDE 3/4" CONDUIT FROM 4" SQUARE BOX TO ACCESSIBLE
CONCEALED LAY-IN CEILING SPACE. WIRING, TERMINATIONS, AND
FACEPLATES BY ELECTRICAL CONTRACTOR.
TTB - 4' x 8' FIRE RETARDANT PLYWOOD
TERMINAL BOARD.
ISOLATED GROUNDIG
Xe FIXTURE MARK NUMBER
WITH EMERGENCY DESIGNATOR
OCCUPANCY SENSOR - WALL SWITCH
FIRE ALARM PULL STATION
FIRE ALARM DEVICE
DUCT SMOKE DETECTOR
PHOTO-ELECTRIC CELL
HEAT DETECTOR
SINGLE STATION SMOKE DETECTOR
SYSTEM SMOKE DETECTOR
MONITOR MODULE
CONTROL MODULE
FIRE ALARM HORN AND STROBE
STROBE ONLY
WATER FLOW BELL
(CANDELLA 75 OR AS INDICATED)
FIRE ALARM SPEAKER
WALL MOUNTED CEILING MOUNTED
WIRELESS ACCESS POINT
SMOKE DETECTOR W/SOUNDER BASE
OCCUPANCY SENSOR - CEILING MOUNT
b = SWITCH DESIGNATOR
ARROW SHOWS ORIENTATION OF LONG FIELD
S
D
MSWITCH - MOMENTARY
DENOTES EMERGENCY LIGHT FIXTURE
CONDUIT RUN CONCEALED
IN CEILING OR WALLS.
CONDUIT RUN UNDERGROUND
CONDUIT AND WIRING
NUMBER OF MINIMUM SIZE #12 WIRES AS REQUIRED.
DEVICE MOUNTING HEIGHTSNOT TO SCALE NOTE:
1. PROVIDE RECESSED BOX TO ACCOMMODATE RECEPTACLE AND TV AND/OR DATA OUTLET AT THISLOCATION. (ARLINGTON #TVBU505 NON-METALIC BOX OR #TVBS505 STEEL BOX OR EQUAL.)
THIS DETAIL IS INTENDED TO DEPICT THE MOUNTING HEIGHTS OF TYPICAL DEVICES INSTALLED IN TYPICALAREAS OF THE BUILDING. THE ARCHITECTURAL ELEVATIONS AND DETAILS SHALL TAKE PRECEDENCE OVER THIS DETAIL.
KITCHEN / COFFEE BARFIRE ALARM DEVICESFINISHED FLOOR
FIREFIGHTERPHONE JACK
MANUAL PULL
THENPUSH IN
PULL DOWN
FIRE
STATIONTELEPHONE
FIGHTERSFIRE
GENERAL DEVICES
RECEPTACLES
PHONE /
RECEPTACLEREFRIGERATOR
FINISHED CEILING
12" (MAXIMUM)
RE
IF
6" (MINIMUM)RECEPTACLECLOCK
FIRE ALARM
ONLY DEVICES
6" (MINIMUM)
WORKSTATIONS
DISPOSALGARBAGE
GFI RECEPTACLECOUNTER TOP
GARBAGE
SWITCHESDISPOSAL
PHONE/DATARECEPTACLES
RECEPTACLES PHONE/DATA
COUNTER TOP
RESTROOM
FINISHED CEILING
4" (ABOVE BACKSPLASH)
AUDIBLE
LIGHT
DISHWASHER
18" 18" 18"
DATA
COAXTV
RECEPTACLEWALL MOUNT TV
COAX/DATA
ORICE MAKER
SWITCHES
MOUNTING HEIGHTMEASURED FROMOPERABLE PART OFDEVICE.
WALLPHONE & RECEPTACLE
RECEPTACLEMICROWAVE
SEE NOTE #1
COUNTER TOPGFI RECEPTACLE
4" (ABOVE BACKSPLASH)
FIRE ALARM VISUAL DEVICES ORCOMBINATION AUDIO/VISUALDEVICES SHALL BE PLACED AT 80"ABOVE THE HIGHEST FINISHEDFLOOR LEVEL WITHIN THE SPACE OR6" BELOW THE CEILING, WHICHEVERIS LOWER.
6"
GENERAL ELECTRICAL NOTES
1) ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE LATEST
ADOPTED VERSION OF OF THE NATIONAL ELECTRICAL CODE (NEC), AND ALL
APPLICABLE FEDERAL, STATE, AND LOCAL CODES.
2) ELECTRICAL CONSTRUCTION DRAWINGS HAVE BEEN PREPARED BASED ON THE
ENGINEER'S FIELD OBSERVATIONS. IT IS THE RESPONSIBILITY OF THE
ELECTRICAL CONTRACTOR TO VISIT THE PROJECT SITE PRIOR TO SUBMITTING
BID IN ORDER TO VERIFY THE EXTENT OF THE CONSTRUCTION WORK AND THE
ACTUAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED.
SUBMITTAL OF BID SHALL BE CONSIDERED PROOF THAT THE CONTRACTOR HAS
VISITED THE JOB SITE AND IS FAMILIAR WITH THE SITE SPECIFIC
CONSTRUCTION REQUIREMENTS.
3) PROTECT ALL ADJACENT SURFACES DURING CONSTRUCTION. ANY SURFACES
DAMAGED SHALL BY REPAIRED BY THE ELECTRICAL CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER.
4) ELECTRICAL CONTRACTOR SHALL COORDINATE INSTALLATION OF ELECTRICAL
SYSTEMS WITH OTHER TRADES. SEE MECHANICAL AND PLUMBING DRAWINGS
FOR EXACT LOCATIONS OF MECHANICAL AND PLUMBING EQUIPMENT.
5) BRANCH CIRCUIT CONDUIT AND WIRING IS NOT SHOWN ON DRAWINGS. ONLY
HOMERUNS SHOWN ALONG WITH CIRCUIT NUMBERS AND (WHERE APPLICABLE)
SWITCH DESIGNATIONS ADJACENT TO EACH DEVICE/LIGHTING FIXTURE.
CONTRACTOR SHALL INSTALL ALL REMAINING BRANCH CIRCUIT CONDUIT AND
WIRING IN COMPLIANCE WITH ALL APPLICABLE SECTIONS OF THE NEC.
6) HOMERUNS ARE SHOWN SEPARATELY TO PRESERVE DRAWING CLARITY.
CONTRACTOR SHALL COMBINE HOMERUNS SERVING LIGHTING AND WIRING
DEVICES AS ALLOWED BY THE NEC.
7) TELEPHONE AND TELEVISION OUTLETS TO BE INSTALLED BY ELECTRICAL
CONTRACTOR.
8) MINIMUM WIRE SIZE SHALL BE #12 AWG.
9) EACH MULTIWIRE BRANCH CIRCUIT SHALL BE PROVIDED WITH A MEANS THAT
WILL SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS AT THE
POINT WHERE THE BRANCH CIRCUIT ORIGINATES.
MARK NO. MANUFACTURER CATALOG NO. VOLTAGE
NO.
LIGHT FIXTURE SCHEDULE
NOTES:
1. PROVIDE ALL NECESSARY MOUTING HARDWARE, HANGERS, CLIPS, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION.
2. PROVIDE SUPPLIES NECESSARY FOR LOW-VOLTAGE LIGHTING.
3. DIMMER SWITCHES SHALL BE SUITABLE FOR LOW-VOLTAGE LIGHTING.
4. SEE DRAWINGS FOR LENGTH TO BE FILLED. STAGGER LIGHTS TO AVOID SHADOWS.
5. CONTRACTOR SHALL VERIFY FIXTURE VOLTAGE AS REQUIRED PER CIRCUITRY ON LIGHTING PLANS.
6. BIDS WILL BE BASED ON SPECIFIED FIXTURES. ALTERNATE FIXTURE PACKAGE WILL BE CONSIDERED.
7. ALL FLUORESCENT BALLASTS SHALL BE ELECTRONIC HIGH FREQUENCY TYPE.
8. FLUORESCENT LAMPS SHALL BE 3500K UNLESS NOTED OTHERWISE.
KEYED NOTES:
EXIT SIGNS SHALL NOT EXCEED 5W PER FACE (10W PER TWO-SIDED FIXTURE).
HANG FIXTURES LEVEL WITH BOTTOM OF BAR JOISTS.
1
2
TTL = TRIPLE TUBE
QT = QUAD TUBE
CFL = MEDIUM SCREW BASE
MOUNTING REMARKS
LAMPS
WATTS/TYPE
FINISH FIXTURE DESCRIPTION
CRI KELVIN
A
8ILED-LD4-32-W-FL-120V-L835-CD4-U
CHAIN MOUNT
120
1
8' HIGH-BAY LED289.8W LED 3500
METALUX
Ae
8ILED-LD4-32-W-FL-120V-L835-EL7W-CD4-U
CHAIN MOUNT
120
1
8' HIGH-BAY LED3500
METALUX
COMES WITH INTEGRAL BATTERY BACKUP
289.8W LED
B
D
E
F
G
H
I
J
K
SURFACE MOUNTED LED DOWNLIGHTHALO SLD612835WHUNVJB SLD6TRMWH 120 1 14.8W LED SURFACE80 3500
LED RECESSED CANHALO PD615ED010-PDM6A835-61VC 120 1 17.1W LED CEILING, RECESSED80 3500
STAIRWELL WITH OCCUPANCY SENSORDAY-BRITE SF-4C-232-UNV-2/1-EB10R-US 120 2 32W T8 WALL, SURFACE WHITE
C METALUX 4SNLED-LD4-54SL-LW-UNV-L835 120 1 50.15W LED CHAIN HANG85 3500 LENSED LED STRIPLIGHT
2X2 LED FIXTUREMETALUX 120 1 34.4W LED CEILING, LAY-IN85 350022CZ-LD4-34-UNV-L835-CD1-U
1SLCB-18-30GMLIGHTING 120 LED UNDERCABINET LIGHTINGSURFACE6.8W LED
3000
METALUX 4SNLED-LD4-54SL-LW-UNV-L835 120 1 50.15W LED CHAIN HANG85 3500 LENSED LED STRIPLIGHT
SHAPER 600-24-W-L2/835-UNV-DL 120 1 12.6W LED SURFACE85 3500 LED VANITY LIGHT
X1 2APC7R 120
XM 2120SEL25SD
EXIT SIGN WITH EGRESS LIGHTS
WHITE HOUSING
RED LETTERS
UNIVERSAL
EGRESS LIGHTS
UNIVERSAL
WITH 90 MIN. SELF- TEST BATTERY BACKUP
WITH 90 MIN. SELF- TEST BATTERY BACKUP
WHITE HOUSING
11.31W LED
1.1W LED
SURE-LITES
SURE-LITES
L CUT-OFF WALL PACKLUMARK XTOR5A-N-CBP 120 1 41W LED WALL, SURFACE BRONZE
PROVIDED WITH EMERGENCY BATTERY PACK3500
LED AREA LUMINAIRE (SINGLE HEAD)COOPER LIGHTING GLEON-AF-01-LED-E1-SL4-BZ 208 1 59W LED 30 FT POLE70 4000 BRONZE PROVIDED WITH SPILL CONTROLM
ADJUSTABLE TRACK LIGHTS
LED NIGHT LIGHT
COMES WITH INTEGRAL BATTERY BACKUP
DF 2X2 LED FIXTUREMETALUX 120 1 34.4W LED CEILING, LAY-IN85 350022CZ-LD4-34-UNV-L835-CD1-U-DF-22-2 PROVIDE DRYWALL FRAME KIT
500 DOLLAR ALLOWANCE FOR FIXTURE TO BE SELECTED
MARK NO. MANUFACTURER CATALOG NO. DESCRIPTION
OCCUPANCY SENSOR SCHEDULE
LEVITON ODS-10-IDW
INFRARED WALL SWITCH, SET OFF FOR 30 MIN.
OSC20-U0W
GLS-ODT-C-CN
LEVITON
CRESTRON
ULTRASONIC, CEILING MOUNTED, SET OFF FOR 30 MIN., 2000 SF (32' X 64' COVERAGE PATTERN)
PROVIDE MATCHING WALL PLATE
1. PROVIDE POWER PACKS, WIRING, ETC. AS NECESSARY FOR A FULL AND COMPLETE
INSTALLATION. SEE TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM.
2. ORIENT CEILING OCCUPANCY SENSORS FOR OPTIMAL SENSITIVITY AND COVERAGE PER
MANUFACTURERS GUIDELINES.
3. VERIFY CIRCUIT VOLTAGES FROM LIGHTING PLANS.
4. PROVIDE MANUFACTURER'S FINAL LAYOUT OF EXACT SENSOR LOCATIONS.
5. INCLUDE FINAL ADJUSTMENTS TO AVOID FALSE "ON" OR DELAYED START.
6. CRESTRON, LUTRON, OR EQUAL.
OSWLR-10W
LEVITON
INFRARED, LONG RANGE CORRIDOR, SET OFF FOR 30 MIN.
NOTES:
LEVITON
OSW12-M0W MULTI-TECHNOLOGY, CORNER MOUNTING, SWIVEL NECK, SET OFF FOR 30 MIN.
LEVITON ODS-10-IDW
INFRARED WALL SWITCH, SET FOR MANUAL "ON", SET OFF FOR 30 MIN.
PROVIDE MATCHING WALL PLATE
ULTRASONIC, CEILING MOUNTED, SET OFF FOR 30 MIN., 2000 SF (50' x 50'), GRACE PERIOD "OFF", SET FOR HIGH SENSITIVITY
TYPICAL OCCUPANCY SENSOR WIRING DIAGRAM
1. SET DEFAULT DELAY OFF FOR 30 MINUTES OR AS SPECIFIED BY OWNER.
PROVIDE USAGE INSTRUCTIONS TO OWNER.
2. POWER PACKS REQUIRED FOR EACH POWER CIRCUIT. OCCUPANCY
SENSORS CONNECTED TOGETHER SHALL ACTIVATE ALL LIGHTING WITH
THE SAME SWITCH / SENSOR DESIGNATORS.
POWER CIRCUIT 1
POWER PACKS
LIGHT LIGHT
LIGHT LIGHT
POWER CIRCUIT 2
SWITCHES
(IF USED)
S
S
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
PROPOSED
FIRE STATION #5
3421 HARRY S. TRUMAN BLVD.
ST. CHARLES, MO 63301
M
M
M
M
PULLBOX
M
M
LP1-2
VIA LCP ZONE 1
4
2
M
M
LP1-4,6
VIA LCP ZONE 2
LP1-8,10
VIA LCP ZONE 3
208V 1ɸ, 2 #10, 1 #10 GRD,
IN 1" CONDUIT (TYPICAL)
208V 1ɸ, 2 #10, 1 #10 GRD,
IN 1" CONDUIT (TYPICAL)
6
GEN
.
T
HARRY S. TRUMAN ROAD
EHLMANN ROAD
GFI
WP
GFI
WP
GFI
WP
LP1-12
7
UTILITY POLE
COMMUNICATION TOWER
1
8
3
0 10' 20' 30' 40'
SCALE: 1" = 20'-0"
SITE PLAN - ELECTRICAL
50' 100'
KEYED POWER NOTES
UTILITY COMPANY TRANSFORMER. COORDINATE ALL SERVICE ENTRANCE
REQUIREMENTS AND METERING WITH AMEREN MISSOURI. (AMJAD ALKFOUF,
TELEPHONE: 636-925-3214)
FURNISH AND INSTALL 4" PVC CONDUIT WITH PULL STRING FOR TELEPHONE
SERVICE ENTRANCE TO IT ROOM 103. COORDINATE WITH AT&T.
SERVICE CONDUCTORS TO NEW UTILITY TRANSFORMER. ELECTRICAL
CONTRACTOR TO PROVIDE ONE 4" EMPTY PVC CONDUIT TO POWER POLE.
COORDINATE LOCATION OF POWER POLE WITH AMEREN MISSOURI.
GENERATOR, SEE SHEET E3.1 FOR MORE INFORMATION.
MONUMENT SIGN, COORDINATE EXACT LOCATION AND ELECTRICAL
REQUIREMENTS WITH OWNER.
1" PVC CONDUIT FROM ELECTRICAL ROOM TO TRAFFIC LIGHT SYSTEM. SEE
CONDUIT TRENCHING DETAIL FOR MORE INFORMATION.
FURNISH AND INSTALL 4" PVC CONDUIT WITH PULL STRING FOR CABLE SERVICE
ENTRANCE TO IT ROOM 103. COORDINATE WITH CHARTER.
SIGNAL CABLES FROM COMMUNICATION TOWER TO CAPTAINS OFFICE. SEE
SYSTEMS SHEET E2.3 FOR MORE INFORMATION.
1
2
3
4
5
6
7
8
TIME
CLOCK
C
LIGHTING CONTROL PANEL - "LCP"
No. Description
Zone
Circuit No.
NOTE: TIME CLOCK TO HAVE 8 YEAR BATTERY BACK-UP AND
AUTOMATIC ASTRONOMICAL CORRECTION FOR DAYLIGHT SAVINGS
TIME, 8 CONTROL ZONES, AND OPTIONAL OVERRIDE CAPABILITY. PANEL
SHALL BE INTERMATIC ET70815CR.
LP1-21
MONUMENT SIGN
SPARE
SPARE
2POLE LIGHTS
3POLE LIGHTS
LP1-4,6
LP1-8,10
LP1-124
BLG EXTERIOR LTG
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
M
M
M
M
M
M
M
M
M
GEN
.
EX ELEC
TRANSFORMER
CONCRETE
CONCRETE
CONCRETE
ASPHALT
ASPHALT
NEW PROPOSED FIRE
DEPARTMENT
ASPHALT
PAVEMENT
CONCRETE
PAVEMENT
CONC.
4
2
"
R
C
P
4
2
"
R
C
P
5
2
"
R
C
P
2
4
"
-
2
7
"
R
C
P
5
2
"
R
C
P
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.6 0.6 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.6 0.7 0.7 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.6 0.7 0.6 0.7 0.8 0.8 0.7 0.8 0.9 0.8 0.7 0.7 0.7 0.6 0.6 0.7 0.7 0.7 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.3 0.4 0.4 0.6 0.8 0.9 0.8 1.0 1.1 1.1 0.9 0.9 1.0 0.9 1.0 1.2 1.2 1.1 0.9 1.0 0.9 0.8 0.9 0.9 0.8 0.8 0.8 0.8 0.9 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.5 0.7 0.7 0.7 0.8 0.9 0.9 1.1 1.2 1.1 1.0 0.9 1.0 0.9 1.0 1.1 1.1 1.0 0.9 1.0 0.9 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.5 0.6 0.6 0.7 0.8 0.9 0.9 1.0 1.0 1.0 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.8 0.7 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.4 0.5 0.5 0.6 0.7 0.8 0.8 0.8 0.9 0.8 0.8 0.7 0.8 0.7 0.7 0.8 0.8 0.8 0.7 0.7 0.7 0.6 0.7 0.8 0.8 0.9 0.9 0.9 0.8 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.3 0.4 0.4 0.4 0.5 0.6 0.6 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.6 0.6 0.6 0.6 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.3 0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.5 0.4 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 1.0 0.9 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.2 0.8 0.8 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.4 0.5 0.6 0.8 0.9 0.9 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.4 0.4 0.3 0.4 0.5 0.6 0.8 0.8 0.9 0.4 0.1 0.1 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.4 0.4 0.4 0.5 0.6 0.7 0.7 0.3 0.1 0.1 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.5 0.5 0.6 0.6 0.8 0.8 0.7 0.7 0.7 0.7 0.7 0.6 0.5 0.4 0.4 0.5 0.6 0.7 0.7 0.3 0.1 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.5 0.6 0.7 0.7 0.8 0.9 0.8 0.9 0.9 0.9 0.8 0.7 0.7 0.6 0.5 0.5 0.5 0.7 0.6 0.3 0.1 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.5 0.7 0.7 0.8 0.9 0.9 0.9 1.0 1.0 0.9 0.8 0.8 0.8 0.7 0.5 0.4 0.5 0.5 0.5 0.2 0.1 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.3 0.4 0.6 0.6 0.5 0.5 0.6 0.7 0.7 0.8 0.9 0.8 0.4 0.4 0.4 0.4 0.3 0.1 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.7 0.8 0.7 0.3 0.3 0.3 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.6 0.8 0.8 0.9 0.3 0.2 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.9 0.9 1.1 0.3 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.5 0.7 0.9 0.9 0.9 0.4 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.5 0.7 0.9 1.0 0.9 0.4 0.3 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.5 0.8 1.1 1.2 0.9 0.5 0.3 0.3 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.5 0.9 1.2 1.1 0.9 0.5 0.3 0.3 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.9 1.1 1.0 0.8 0.5 0.3 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.9 0.9 0.8 0.6 0.4 0.3 0.2 0.2
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.3 1.0 0.9 0.8 0.7 0.5 0.3 0.2 0.2 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.3 0.9 0.8 0.8 0.6 0.5 0.3 0.2 0.2 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.7 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.6 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.5 0.7 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.5 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1
Luminaire Schedule
Symbol Qty Label Arrangement LLFDescription
Lum. Lumens Lum. Watts
8 FIXTURE M SINGLE 0.9 GLEON-AF-01-LED-E1-SL4 592259
Calculation Summary
Label CalcType Units Avg Max Min
EAST_PARKING_LOT Illuminance Fc 0.58 1.0 0.3
WEST_PARKING_LOT IlluminanceFc 0.88 1.3 0.6
0 10' 20' 30' 40'
SCALE: 1" = 20'-0"
PHOTOMETRIC SITE PLAN
50' 100'
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
A A
A A
Ae A
A
Ae
A
A
A
Ae
A Ae Ae
Ae A A
A
Ae
B
SS
SS
SS
S
S
S
B
SS
A
S
S
S
S S
C
C
D
D
D
D
D
D
D
D
D
D
D D
D
D
D
D
F
F
F
C
G
G
G
G
G
G
G
H
H
H
H
J J J J J J J
J
C
H
EM EM
EM
EM
X1
X1
X1
X1
X1
X1
D
D D
D
K
H
H
H H
K
H
HH
H
K
J
G
IceMachine
H
H
H
H
L
L
L
L
H H H H
RH
PP1
MP1
SS
2
CC
CC
D
J
J
J
J
J
J
J
J
J
J
J
J
H
H
F
1
1 1
1
11
E
E
DS
DS
DS
DS
D
H H H H H
I I I I
e
e e e
ee
e ee
e e f f
f
f
f
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
D
LP1-1
LP1-3
LP1-5 LP1-7 LP1-9 LP1-11
LP1-13
LP1-15
3 3 3 3 3
LP1
LCP
a
b
c
d
a
b
c
d
S
a
a
a
a
a
b
b
b
b
b
c
c
c
c
c
d
d
d
d
d
S
ef
gg g g g g g
g
S
5
5
SS
3
S
5
S
3
S
j
j
j
j
j
jj
L
S
k
k k
k k
k k
k
k
E
k
E
k
LP1-12
VIA LCP ZONE 4
L
S
S
m
m m m
m m m
m m m
m m m
m
e
e
e
e
6
H H H HH
FIRST FLOOR LIGHTING PLAN
SCALE: 1/8"=1'-0"
SECOND FLOOR LIGHTING PLAN
SCALE: 1/8"=1'-0"
GENERAL LIGHTING NOTES
1. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF
LIGHT FIXTURES.
2. CONNECT ALL EXIT SIGNS TO AN UNSWITCHED LEG OF CIRCUIT SHOWN.
3. CONNECT NIGHT LIGHTS TO AN UNSWITCHED LEG OF CIRCUIT SHOWN.
4. FOR LIGHTS WITH EMERGENCY BATTERY BACK-UP: NORMAL DUTY BALLAST TO
BE SWITCHED. EMERGENCY BALLAST TO OPERATE UPON POWER FAILURE
ONLY.
5. COORDINATE HIGH BAY LED LIGHTS WITH INFRARED HEATER LOCATIONS TO
AVOID OVERHEATING OF LED FIXTURE. COORDINATE FIXTURE LOCATIONS
WITH OVERHEAD RECEPTACLES, JOISTS, & ENGINE BAY GARAGE DOORS AS
WELL.
6. FOR ALL BRANCH CIRCUIT HOMERUNS OVER 100' USE #10 WIRING. FOR ALL
BRANCH CIRCUIT HOMERUNS OVER 150' USE #8 WIRING.
KEYED LIGHTING NOTES
KEYED LIGHTING NOTES
FURNISH AND INSTALL INDUSTRIAL CEILING FAN. PROVIDE LEADING EDGE
CEILING FAN MODEL NUMBER: 56001. MOUNT CEILING FAN AT THE SAME
HEIGHT AS LIGHT FIXTURES. COORDINATE FINAL LOCATION WITH
ARCHITECT/OWNER.
SOLID STATE MOTOR SPEED CONTROLS FOR CEILING FANS. PROVIDE LEADING
EDGE CONTROL MODEL NUMBER: 12006.
COORDINATE FAN CONTROLS WITH MANUFACTURER PRIOR TO INSTALLATION.
SWITCHES FOR WALL FAN RECEPTACLES. SEE SHEET E2.2 FOR RECEPTACLE
LOCATIONS. COORDINATE FAN CONTROLS WITH MANUFACTURER PRIOR TO
INSTALLATION.
PROVIDE 2 SWITCHES. ONE FOR CONTROL OF LIGHTS AND THE OTHER FOR
CONTROL OF EXHAUST FAN.
STAIRWELL LUMINAIRE HAS INTEGRAL OCCUPANCY SENSOR. CONNECT
FIXTURE TO UNSWITCHED LEG OF CIRCUIT SHOWN.
1
2
3
4
5
6
S
C
K
H
B
X1
DF DF
DFDF
DF DF
DF DF
DF DF
DF DF
SS
H
LP1-17
SS
SS
4
a
a a
a a
a a
a a
a a
a a
b
b
b
5
6
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
IceMachine
GFI
S
OD
1
S
OD
1
S
OD
1
S
OD
1
S
OD
1
S
OD
1
GEN
ERATO
R
22
22
22
36"
AF
36"
AF
3 4 3 4 3 4
36"
AF
36"
AF
36"
AF
36"
AF
36"
AF
36"
AF
36"
AF
36"
AF
3 4 3 4
GFI GFI
36"
AF
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
3 4
GFI
10
GFI
5
5
GFI
GFI
GFI
TRANSFORMER
36"
AF
36"
AF
36"
AF
36"
AF
36"
AF
7
(TYP.)
8
(TYP.)
48"
AF
48"
AF
48"
AF
9
9
2
2
2
3 4
3 4
11
12
(TYP.)
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
GFI
WP
EXHAUST FAN
CONT PANEL
ALL RECEPTACLES IN
APPARATUS BAY TO BE
MOUNTED AT 30" TO
BOTTOM OF BOX
GFI
WP
GFI
WP
PP1-1
PP1-3
PP1-5
PP1-7
PP1-9
PP1-11
PP1-13
PP1-15
PP1-17
PP1-19
GFI
GFI
PP1-21
PP1-27
PP1-25
PP1-23
PP1-29
PP1-31
PP1-33
PP1-41 PP1-37,39
PP1-35
PP1-45
PP1-43
PP1-47
PP1-47
PP1-47 PP1-47
PP1-49
PP1-49
PP1-49PP1-49
PP1-37,39
PP1-51,53
PP1-55,57
PP1-59,61
PP1-47
PP1-49
PP1-63 PP1-63
PP1-63
PP1-63
PP1-63
PP1-63
PP1-63
PP1-63
PP1-65
PP1-65PP1-65
PP1-65
PP1-65
PP1-65
PP1-65
PP1-65
PP1-2 PP1-4
PP1-8 PP1-6
PP1-10
PP1-12
PP1-14
PP1-16
PP1-18
PP1-18
PP1-18
PP1-18
PP1-18
PP1-18
PP1-18
MP1-2,4 MP1-6,8 MP1-10,12
MP1-14,16
MP1-18,20
PP1-22,24
PP1-44
PP1-46
PP1-48PP1-50
PP1-52
PP1-54
PP1-54
PP1-64,66
PP1-68
PP1-56,58
PP1-60,62
PP1-63
PP1-65
PP1-71
PP1-73
PP1-49
GFI
WP
3
4
PP1-7513
PP1
MP1
LP1
LCP
PP1-35
14
15
16
FIRST FLOOR POWER PLAN
SCALE: 1/8"=1'-0"
SECOND FLOOR POWER PLAN
SCALE: 1/8"=1'-0"
KEYED POWER NOTES
POWER CONNECTION FOR OVERHEAD DOOR. ALL DOOR CONTROL DEVICES
SUPPLIED BY GENERAL CONTRACTOR AND INSTALLED BY ELECTRICAL
CONTRACTOR. DOOR SAFETY SENSORS AT (1) AT 12", (1) AT 36", AND (1) AT
90" MOUNT DOOR CONTROLLER ABOVE DOOR CONTROL STATION. MOUNT TOP
OF DOOR CONTROL STATION AT 48"
MOUNT RECEPTACLE TO UNDERSIDE OF JOIST. COORDINATE EXACT LOCATION
WITH OWNER.
VERIFY TELEVISION MOUNTING HEIGHT WITH ARCHITECT / OWNER.
MATCH RECEPTACLE HEIGHT TO TV OUTLET HEIGHT.
EXHAUST FAN SHALL BE SWITCHED WITH ROOM OCCUPANCY SENSOR OR LIGHT
SWITCH. SEE LIGHTING DRAWINGS FOR ELECTRICAL CIRCUIT NUMBERS.
NOT USED.
MOUNT RECEPTACLE IN DRESSER SHELVE. VERIFY EXACT MOUNTING HEIGHT
WITH DRESSER MANUFACTURER / OWNER.
MOUNT RECEPTACLE IN GEAR ROOM LOCKER. COORDINATE MOUNTING
HEIGHT WITH LOCKER MANUFACTURER / OWNER.
THREE BUTTON (UP/DOWN/STOP) OVERHEAD DOOR CONTROLS INSTALLED AND
CONNECTED BY E.C. FURNISHED BY OTHERS.
MATCH RECEPTACLE HEIGHT TO TV OUTLET HEIGHT AT 60" AFF. SEE TV
ELEVATION ON THIS SHEET FOR MORE INFORMATION.
PROVIDE POWER FOR EXTERIOR SIGN. CONNECT VIA LIGHTING CONTROL
PANEL.
PROVIDE SOFFIT MOUNTED RECEPTACLE FOR CHRISTMAS DECORATIONS.
CONNECT VIA TIME CLOCK LOCATED IN ELECTRICAL ROOM.
FOR BOTH GAS GRILL AND STOVE, PROVIDE EMERGENCY STOP PUSH BUTTON
(RED) TO ACTIVATE GAS SHUTOFF VALVE. ALSO, PROVIDE PUSHBUTTON
(GREEN) TO RESET SHUTOFF VALVE TO "OPEN" POSITION. PROVIDE RELAY FOR
GAS SHUTOFF VALVE AND ACTIVATE RELAY THROUGH STATION ALERT SYSTEM.
MOTORIZED LOUVER TO INTERLOCK WITH EF-1
EXHAUST FAN SHALL BE ACTIVATED BY EITHER MEANS OF WALL SWITCH,
CARBON MONOXIDE DETECTOR OR NITROGEN DIOXIDE DETECTOR.
COORDINATE RESIDENTIAL HOOD REQUIREMENTS WITH GENERAL
CONTRACTOR BEFORE INSTALLATION.
PROVIDE CEILING JUNCTION BOX FOR FUTURE WALL FAN / TV IN FITNESS
ROOM 204.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
GENERAL POWER NOTES
1. SEE EQUIPMENT DATA SCHEDULE FOR ADDITIONAL INFORMATION ON
MECHANICAL EQUIPMENT CIRCUITRY.
2. COORDINATE OUTLET LOCATIONS WITH OWNER'S FURNITURE LAYOUT.
3. ALL CONDUIT PASSING THROUGH CLASSIFIED AREAS TO BE RIGID STEEL.
5
GFI
PP1-20
GFI
PP1-22
PP1-24
PP1-34
PP1-36
PP1-38
17
17
(TYP.)
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
IceMachine
2
3
2
3
2
3
2
3
2
3
2 3 2 3
2 3
2 3 2 3
2
3
43
43
43
43
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
5
6
7
8
TTB
7
10
FIRST FLOOR SYSTEMS PLAN
SCALE: 1/8"=1'-0"
SECOND FLOOR SYSTEMS PLAN
SCALE: 1/8"=1'-0"
KEYED FIRE ALARM NOTES
PROVIDE CONTROL MODULE FOR CONTROL OF AIR HANDLING UNIT DUCT
DETECTOR. PROVIDE ALL WIRING, HARDWARE, SOFTWARE AND PROGRAMMING
AS REQUIRED BY MANUFACTURER.
ALERT SYSTEM SPEAKER / EGRESS LIGHT COMBINATION. ALERT SYSTEM TO BE
FURNISHED BY OWNER AND INSTALLED BY ELECTRICAL CONTRACTOR. VERIFY
FINAL LAYOUT WITH OWNER.
PROVIDE HOMERUN WIRING FROM ALERT SYSTEM SPEAKER TO ALERT SYSTEM
AMPLIFIER LOCATED IN THE CAPTAIN'S OFFICE.
ALERT SYSTEM SPEAKER. FURNISHED BY OWNER AND INSTALLED BY ELECTRICAL
CONTRACTOR. VERIFY FINAL LAYOUT WITH OWNER.
COMMUNICATION TOWER LOCATION. EXTEND ALL SIGNAL CABLES TO HEAD-END
LOCATIONS PER OWNER'S REQUIREMENTS.
(2) 1-1/2" PVC CONDUIT RUN BELOW GRADE FOR RADIO AND
TELECOMMUNICATIONS WIRING.
1" PVC CONDUIT RUN BELOW GRADE FOR SATELLITE TV. STUB UP CONDUIT INTO
IT ROOM.
2-WAY RADIO AND AMPLIFIER.
CABLE SERVICE ENTRANCE, SEE SITE PLAN E1.2 FOR MORE INFORMATION.
TELEPHONE SERVICE ENTRANCE, SEE SITE PLAN E1.2 FOR MORE INFORMATION.
1
2
3
4
5
6
8
7
9
10
2
3
2
3
2 3
NFS-320
120V
FIRE ALARM RISER DIAGRAM
FACP
KEYED NOTES
MONITOR MODULE FOR KITCHEN HOOD AND FIRE SUPPRESION
SYSTEM.
THE SPRINKLER SYSTEM HAS NOT BEEN DESIGNED AT THIS TIME.
VERIFY WATERFLOW AND TAMPER SWITCH LOCATIONS WITH
SPRINKLER SYSTEM CONTRACTOR IN FIELD.
SEE FLOOR PLANS FOR EXACT QUANTITIES AND LOCATIONS.
NOTES:
1. WIRING AS REQUIRED BY MANUFACTURER. WIRING MAY BE RUN
OPEN IN CONCEALED SPACES OF WALLS AND CEILING AS
ALLOWED BY THE N.E.C.
2. SEE PLANS FOR EXACT QUANTITIES OF DEVICES.
TG-7FS
WIRELESS
HOOD
KITCHEN
CENTERLINE 18"AFF
TELEPHONE
BACKBOARD
PUNCH DOWN
BLOCKS
TELEPHONE / DATA RISER DIAGRAM
4" CONDUIT
KEYED NOTES
RUN RG-6 TO I.T. ROOM AND BUNDLE AND TAG FOR CABLE PROVIDER
TERMINATION. LEAVE SUFFICIENT EXCESS CABLE FOR CABLE PROVIDER
CONNECTION. COORDINATE WITH CABLE PROVIDER. PROVIDE COAX
CONNECTOR AND FACEPLATE. PROVIDE RJ-45 DATA JACK IN SAME
FACEPLATE.
ELECTRICAL CONTRACTOR TO PROVIDE WRITTEN DOCUMENTATION OF
TESTING FOR ALL PHONE AND DATA CABLING.
RACK AND PATCH PANEL BY ELECTRICAL CONTRACTOR.
A
B
CAT 6
PATCH PANEL
DATA /
TELEVISION
OUTLET
COAX & RJ45
(TYPICAL)
TELEPHONE /
DATA OUTLET
RJ45 & RJ45
(TYPICAL)
FACEPLATES
TELEPHONE
OUTLET
RJ45
(TYPICAL)
COAX
CABLE
BUNDLE
I.T. ROOM
2" PVC CONDUIT
A
TO PULLBOX, SEE
CABLE
SERVICE
ENTRANCE
4" CONDUIT
TO CABLE COMPANY
B
APC SMART-UPS X 2000VA
RACK/TOWER LCD 100-127V
(OUTPUT 1800W)
2 CAT 6 1 CAT 6
1 CAT 6
GENERAL NOTES - LOW-VOLTAGE WIRING
1. PLENUM RATED CABLE SHALL BE USED IN ALL RETURN AIR PLENUM
SPACES.
2. ALL EXPOSED CABLING AND CABLING ABOVE ACCESSIBLE CEILINGS
MAY BE HUNG ON J-HOOKS, MAXIMUM 48"O/C.
3. PROVIDE WET-LOCATION, INDOOR/OUTDOOR RATED CABLES FOR ALL
UNDERGROUND AND/OR UNDERSLAB LOCATIONS.
CONNECTION, SEE
SITE PLAN
SITE PLAN
2" PVC CONDUIT
1" CONDUIT
TO COMM. TOWER,
SEE SITE PLAN
C
C
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
600A
120/208V
3PH, 4W
PP1
NEW SERVICE ENTRANCE ONE LINE DIAGRAM
SCALE: NTS
GENERATOR
ATS
400A
4 POLE
400
125 KW
14
100A
SPARE
14
1-1/2"C.
14
200A
120/208V
3PH, 4W
MP1
NEW UTILITY
PAD-MOUNTED TRANSFORMER
400A
CT COMP
METER
M
MAIN
14
32
100A
120/208V
3PH, 4W
LP1
22
FUTURE SOLAR
P L A N
NOTES:
1. PROVIDE ANCHOR BOLTS AND SEISMIC VIBRATION ISOLATION PER
GENERATOR MANUFACTURERE'S REQUIREMENTS. (VIBRATION
ISOLATORS FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL
CONTRACTOR)
2. DESIGN BASED ON FIRM ORIGINAL EARTH AT A MAXIMUM ALLOWING
BEARING PRESSURE OF 1000 LBS. PER SQUARE FOOT.
3. MINIMUM CLEARANCE ABOVE GRADE IS 6". MINIMUM DEPTH BELOW
GRADE IS 6". PAD TO BE UNIFORM THICKNESS THROUGHOUT AND
CROWNED 1/8" / FOOT IN SHORT DIMENSION TO PREVENT PONDING.
GENERATOR PAD DETAIL
SCALE: 1/4" = 1'-0"
E L E V A T I O N
#5 RE-BAR OFFSET 4" FROM
OPENING ALL SIDES. EXTEND
APPROXIMATELY 18" PAST
OPENING AS SHOWN.
#5 REBAR EACH SIDE OF
SLOT. (SEE PLAN)
#5 RE-BAR (TYPICAL ALL)
4000 PSI CONCRETE
NATURAL GRADE
GENERATOR GROUNDING DETAIL
Bolted, rivieted, or welded
Grounding
electrode
conductor
Main
bonding
jumper
Bonding
jumper
Service
equipment
Bonding
jumper #1/0 CU
Concrete-encased
electrode
Metal Water
pipe
Ground rod, 3/4" x 10' copper
GROUND ELECTRODE SYSTEM
BONDING DETAIL
N
3/0 Copper
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S
EQUIPMENT DATA SCHEDULE
MARK LOCATION
FURNISH.
2
BY
CONN.BY
INST.BY/
EQUIPMENT DATA
MOTOR OR
3
HP/KW/A
PHASE
VOLTS/
CONN.BY
FUSE SIZE
AT EQUIPMENT
DISCONNECT SWITCH
NEMA ENCLOS.TYPE
5
TYPE
SWITCH/
NEMA
BY
FURNISH.
CONN.BY
INST.BY/
NEMA ENCLOS.
SIZE TYPE
ACCESS.
STARTER
SWITCH/
FUSE SIZE
TYPE
6
BY
FURNISH.
7
CONTROL
WIRING BY
REMARKS
8
2
SPECIFICATION DIVISION NUMBER:
DIVISION 14 - CONVEYING SYSTEMS
DIVISION 15 - MECHANICAL
DIVISION 16 - ELECTRICAL
DIVISION 17 - CONTROLS
GC - GENERAL CONTRACTOR
3
HORSEPOWER (HP) IS SHOWN UNLESS AMPS (A) OR
KILOWATTS (KW) ARE CALLED OUT.
4BRANCH CIRCUIT DEVICE TYPE
CB - CIRCUIT BREAKER
FS - FUSIBLE SWITCH
5 NF - NON FUSED
F - FUSED
TOG - TOGGLE
SHT - SHUNT TRIP FUSIBLE SWITCH
REC - RECEPTACLE
PWCP - PRE-WIRED CONTROL PANEL
6
STARTER TYPE:
COMB - COMBINATION MAGNETIC FVNR
WITH FUSIBLE DISCONNECT SWITCH
FVNT - FULL VOLTAGE NON-REVERSING
MAGNETIC STARTER WITH
NONFUSIBLE DISCONNECT SWITCH
MAN - MANUAL STARTER
SDS - STAR DELTA STARTER
PWCP - PREWIRED CONTROL PANEL
VFD - VARIABLE FREQUENCY DRIVE
2S2W - 2 SPEDD 2 WINDING
2S1W - 2 SPEED SINGLE WINDING
TC - TIME CLOCK CONTROLLER
7
ACCESSORIES:
HOA - HAND-OFF-AUTO SWITCH MAINTAINED
HLOA - HIGH-LOWOFF-AUTO SELECTOR
SWITCH OR PUSHBUTTON
P () - PILOT LIGHT (QTY.) - SEE SPEC.
FOR COLOR OF LIGHTS.
SS - START-STOP PUSHBUTTON MAINTAINED
CONTACT SELECTOR SWITCH OR PUSHBUTTON.
SSM - START-STOP MOMENTARY CONTACT
TDR - TIME DELAY RELAY
8
KEY TO REMARKS:
(1) FIRE ALARM INTERLOCK
(2) INTEGRAL DISCONNECT SWITCH
(3) MOUNT DISCONNECT SWITCH ON
EQUIPMENT HOUSING
(4) EQUIP DISCONNECT SWITCH WITH PILOT
LIGHT (LIGHT ON WITH LOAD ON)
(5) CONNECT EXHAUST FAN TO LOAD SIDE
OF LIGHT SWITCH IN ROOM.
(6) TIME CLOCK CONTROLLER
(7) CONTROLLED BY AQUASTAT
(8) EC TO WIRE UP POWER AND CONNECT THE SMOKE DETECTOR
REMOTE INDICATOR AND RESET BUTTON PROVIDED WITH THE
FURNACE SMOKE DETECTOR.
(9) SEE HENRY SCHEIN DENTAL EQUIPMENT INSTALLATION
DRAWINGS
ALL MAGNETIC AND SOLID STATE STARTERS ARE TO BE EQUIPPED WITH AUXILIARY CONTACTS, PILOT LIGHTS AND FUSED CONTROL POWER TRANSFORMERS. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
N
I
L
E
2
1
3
4
BRANCH CIRCUIT DATA
SIZE
CONDUIT
CONDUCTORS
GRDPHASESIZETYPE
CIRCUIT DEVICE
BRANCH
DESIG.
PANEL
PLANS4
*
FOR BREAKER SIZE, SEE PANEL SHEDULES
1 FURNISHED EQUIPMENT LOADS:
PRIOR TO INSTALLATION OF CONDUIT AND WIRE,
VERIFY ACTUAL FURNISHED EQUIPMENT VOLTAGE
AND LOAD DATA. REPORT DISCREPANCIES TO
ARCHITECT.
1
MOCPMCA
5
6
7
8
9
10
11
FCU-1 FAN COIL UNIT REFER TO PLANS 15
208/1
.8 MCA
15 /16
MP1CB
SEE PANEL MP1
12 123/4"
TOG 1 20 16 16/1615 16 15PWCP
FCU-2
FCU-3
REFER TO PLANS
REFER TO PLANS
15
15
208/1 15 /16
MP1CB
12 12 3/4"
1 16 16/1620
15 16 15
208/1 15 /16
MP1CB
12 12 3/4"
16 16/16
15 16 15
FCU-4REFER TO PLANS 15
REFER TO PLANS 15208/1
15 /16
15 /16
208/1
MP1
MP1
CB
CB
12 12 3/4"
16 16/16
1212
3/4"16 16/16
15 16 15
15 16 15
12
13
14
17
18
19
REFER TO PLANS 15208/1 15 /16
MP1CB
12 1215 16 15
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
15
15
15
15
15
15
15
15
3.3 MCA
1/2 HP
ELECTRIC UNIT HEATER
ELECTRIC UNIT HEATER
2 KW
2 KW
208/1
208/1
208/1
208/1
208/1
208/1
120/1
208/3
15 /16
15 /16
15 /16
15 /16
15 /16
15 /16
15 /16
15 /16
MP1
MP1
MP1
MP1
MP1
MP1
MP1
MP1
CB
CB
CB
CB
CB
CB
CB
CB
12
12
12
123/4"
3/4"16 16/16
16 16/16
15 16 15
15 16 15
20
1212
3/4"
TOG
3/4"
16 16/16
1 20 16 16/16
15 16 15
- - 15 16 15PWCP
- -
TOG
1 20 16 16/16
- - 15 16 15
- -
2012 12 3/4"
2012 12 3/4"
NF 1 30
NF 1 30
- - 15 16 15
- -
- - 15 16 15
- -
48 WATTS
EXHAUST FAN
EXHAUST FAN
15
15
120/1
120/1
15 /16
LP1CB
203/4"
15 /16
LP1CB
203/4"
TOG
TOG
1 20 16 16/16
- - 15 16 15
- -
1 20 16 16/16
- - 15 16 15
- -
43 MCA 50
8 10 3/4"
F
3R 60 / 50 16 16/16
- - 15 16 15-
- -
16 16/16
15
1/2 HP
208/1 15 /16
MP1CB
203/4"
NF
1 30 16 16/16
15 16 15
FCU-5
FCU-6
FCU-7
FCU-8
FCU-9
DOA-1
F-1
CU-1
EUH-1
EUH-2
EF-1
EF-2
EF-3
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
FAN COIL UNIT
DEDICATED OUTDOOR AIR UNIT
FURNACE
HEAT RECOVERY UNIT
EXHAUST FAN21
22
15208/3 15 /16
MP1CB
27.5 MCA 35
8 10 3/4"
F
3R 60 / 35 16 16/16
- - 15 16 15-
- -CU-2
HEAT RECOVERY UNIT
1515 /16
- --
- -APS-1
AIR PURIFICATION SYSTEM
20
19
15INFARRED HEATER
4.6A
120/1 15 /16
MP1CB
12 3/4"
- -
15 16 15
- -
4.6A
INFARRED HEATER15
120/1 15 /16
MP1CB
12
- -
15 16 15
- -
15
4.6A
120/1 15 /16
CB
3/4"
15 16 15
IRH-1
IRH-2
IRH-3
INFARRED HEATER
21
20
15
.6 MCA
15 16 15
BS-1 BRANCH SELECTOR BOX
20
15
.4 MCA
15 16 15
BS-2 BRANCH SELECTOR BOX
23
15
.2 KW16 16/16
15 16 15
IH-1 INTAKE HOOD (DAMPER)
24
5 KW
DUCT HEATER15
208/1 15 /16
15 16 15
DH-1
25
15
5 KW
208/1 15 /16 15 16 15
DH-2 DUCT HEATER
26
REFER TO PLANS
15
3.4 MCA
208/1 15 /16
MP1CB
1212
3/4"16 16/16
15 16 15
FCU-10FAN COIL UNIT
3/4"
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
REFER TO PLANS
15ELECTRIC UNIT HEATER
3 KW
208/1 15 /16
MP1CB
2012 12 3/4"
NF 1 30
- - 15 16 15
- -EUH-3
REFER TO PLANS
15ELECTRIC UNIT HEATER
.5 KW
120/1 15 /16
MP1CB
2012 12 3/4"
NF 1 30
- - 15 16 15
- -EUH-4
REFER TO PLANS
15
27
1212
3/4"1212
28
29
30
31
32
EXHAUST FAN15
120/1 15 /16
LP1CB
203/4"
TOG
1 20 16 16/16
- -
- -EF-4
REFER TO PLANS
212 WATTS
EXHAUST FAN15
120/1 15 /16
MP1CB
203/4"
TOG
1 20 16 16/16
- -
- -EF-5
REFER TO PLANS
EXHAUST FAN15
120/1 15 /16
MP1CB
203/4"
TOG
1 20 16 16/16
- -
- -EF-6
REFER TO PLANS
EXHAUST FAN15
120/1 15 /16
MP1CB
203/4"
TOG
1 20 16 16/16
- -
- -EF-7
REFER TO PLANS
100 WATTS
EXHAUST FAN15
120/1 15 /16
LP1CB
203/4"
TOG
1 20 16 16/16
- -
- -EF-8
REFER TO PLANS
15 16 15
15 16 15
15 16 15
15 16 15
15 16 15
16 16/16
16 16/16
16 16/16
16 16/16
- -
- -
-
-
-
-
-
12 12
12 12
12 12
12 12
12 12
12 12
12 12
12 12
5
5
5
5
-
-
-
-
-
-
-
MP112
3/4"
12
12
12
- -
- -
-
-
-
120/1 15 /16
MP1CB
12 3/4"12
120/1 15 /16
MP1CB
12 3/4"12
- -
- -
-
- -
- -
-
NF
1 30120/1 15 /16
MP1CB
2012 3/4"12
16 16/16
NF
1 30MP1
CB30
10 3/4"10
16 16/16
NF
1 30MP1
CB30
10 3/4"10
- -
- -
-
- -
- -
-
- -
- -
-
PWCP
.8 MCA
.8 MCA
.8 MCA
.8 MCA
.8 MCA
.8 MCA
.8 MCA
.8 MCA
15
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
120
TOG
PWCP
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
SEE PANEL MP1
APS-216 AIR PURIFICATION SYSTEM 15
15 /16
POWERED FROM INTERNAL EQUIPMENT
POWERED FROM 24V POWER SUPPLY
212 WATTS
212 WATTS
127 WATTS
127 WATTS
SEE PANEL MP1
SEE PANEL MP1
20
TOG
1 20 16 16/16
TOG
1 20 16 16/16
TOG
1 20 16 16/16
TOG
1 20 16 16/16
TOG
1 20 16 16/16
SEE PANEL MP1
SEE PANEL MP1
COORDINATE LOCATION WITH MECH.
COORDINATE LOCATION WITH MECH.
TO OPERATE WITH EF-1
PANEL "LP1"
LOAD
LOAD, KVAO.C.P.
CKT PH CKT
O.C.P.LOAD, KVA
LOAD
LTG REC MTR HEAT A/C A P P A LTG REC MTR HEAT A/C
LTG - BUNK / LOCK / LOUNGE 1.1 20 1 1 A 2 1 20 1.0 MONUMENT SIGN
LTG - KIT / DAY / OFF / EXT 1.1 20 1 3 B 4
2 20 0.2 SITE LIGHTING
LTG - BAY 1.5 20 1 5 C 6
LTG - BAY 1.5 20 1 7 A 8
2 20 0.2 SITE LIGHTING
LTG - BAY 1.5 20 1 9 B 10
LTG - BAY 1.5 20 1 11 C 12 1 20 0.5 BLG EXTERIOR LTG
BAY FANS 1.2 20 1 13 A 14 1 20 SPARE
LTG - EAST 1.2 20 1 15 B 16 1 20 SPARE
LTG - 2ND FLOOR 0.7 20 1 17 C 18 1 20 SPARE
SPARE 20 1 19 A 20 1 20 SPARE
SPARE 20 1 21 B 22 1 20 SPARE
SPARE 20 1 23 C 24 1 20 SPARE
SPARE 20 1 25 A 26 1 20 SPACE
SPARE 20 1 27 B 28 1 20 SPACE
SPACE 20 1 29 C 30 1 20 SPACE
SPACE 20 1 31 A 32 1 20 SPACE
SPACE 20 1 33 B 34 1 20 SPACE
SPACE 20 1 35 C 36 1 20 SPACE
SPACE 20 1 37 A 38 1 20 SPACE
SPACE 20 1 39 B 40 1 20 SPACE
SPACE 20 1 41 C 42 1 20 SPACE
ODD CIRCUIT CONNECTED, KVA
10 0 1 0 0 2 0 0 0 0 EVEN CIRCUIT CONNECTED KVA
ODD & EVEN CONNECTED KVA 12 0 1 0 0
DEMAND FACTOR 1.25 10+50% 1.0 1.0 1.0
TOTAL DEMAND KVA 15 0 1 0 0 16
* *
PANEL DESCRIPTION ALL CIRCUIT BREAKERS SHALL BE SERIES
RATED FOR 65,000 AIC WITH MAIN CIRCUIT
BREAKER.
PROVIDE INTERNAL TRANSIENT VOLTAGE
SURGE SUPPRESSOR
AMPS 100 CONNECTED KVA 13.2 KVA
VOLTAGE 120 / 208 DEMAND KVA 16.2 KVA
PHASE 3PH 4W CONNECTED AMPS 36.7 AMPS
MAIN LUG ONLY 100 DEMAND AMPS 45.1 AMPS
FEED
AIC RATING
LOCATION 115
PANEL "MP1"
LOAD
LOAD, KVAO.C.P.
CKT PH CKT
O.C.P.LOAD, KVA
LOAD
LTG REC MTR HEAT A/C A P P A LTG REC MTR HEAT A/C
FCU-1, 2, 3, 4, 50.8 20 2
1 A 2
2 20 2.3 OVERHEAD DOOR
3 B 4
FCU-6, 7, 8, 9, 101.4 20 2
5 C 6
2 20 2.3 OVERHEAD DOOR
7 A 8
DOA-1 0.7 15 2
9 B 10
2 20 2.3 OVERHEAD DOOR
11 C 12
CU-1 15.5 50 3
13 A 14
2 20 2.3 OVERHEAD DOOR
15 B 16
17 C 18
2 20 2.3 OVERHEAD DOOR
CU-2 9.9 35 3
19 A 20
21 B 22
2 20 2.3 OVERHEAD DOOR
23 C 24
CU-3 3.9 30 2
25 A 26 1 20 0.5
EUH-4 (RISER 127)
27 B 28
2 20 0.9 EF-1
EUH-1 (KITCHEN 107)
2.0 20 2
29 C 30
31 A 32 1 20 0.2 EF-5
EUH-1 (CORR. 108)
2.0 20 2
33 B 34 1 20 0.2 EF-6
35 C 36 1 20 0.2 EF-7
EUH-1 (ENTRY 101)
2.0 20 2
37 A 38
2 20 0.4
EBB-1 (BUNK 121)
39 B 40
EUH-1 (CORR. 116)
2.0 20 2
41 C 42
2 20 0.4
EBB-1 (BUNK 120)
43 A 44
EUH-1 (CORR. 116)
2.0 20 2
45 B 46
2 30 5.0 DH-1
47 C 48
EUH-1 (STAIR 123)
2.0 20 2
49 A 50
2 30 5.0 DH-2
51 B 52
EUH-1 (EXTRACTOR 124)
2.0 20 2
53 C 54
2 20 0.4
EBB-1 (BUNK 119)
55 A 56
SPARE 20 1 57 B 58
2 20 0.4
EBB-1 (BUNK 118)
SPARE 20 1 59 C 60
F-1 1.2 20 1 61 A 62
2 20 0.6
EBB-2 (BUNK 117)
IRH-1 0.6 20 1 63 B 64
IRH-1, 21.1 20 1 65 C 66
2 20 3.0
EUH-3 ( WORK ROOM 128)
BS-1, 20.1 20 1 67 A 68
INTAKE HOOD (DAMPER)
0.2 20 1 69 B 70
2 20 2.0
EUH-2 (STAIR 123)
SPARE 20 1 71 C 72
SPARE 20 1 73 A 74 1 20 SPARE
SPARE 20 1 75 B 76 1 20 SPARE
SPARE 20 1 77 C 78 1 20 SPARE
SPARE 20 1 79 A 80
3 30SPACE 20 1 81 B 82
SPACE 20 1 83 C 84
ODD CIRCUIT CONNECTED, KVA
0 0 4 16 29 0 0 15 18 0 EVEN CIRCUIT CONNECTED KVA
ODD & EVEN CONNECTED KVA 0 0 20 33 29
DEMAND FACTOR 1.25 10+50% 1.0 1.0 0.0 * HEATING AND COOLING ARE NON-COINCIDENTAL LOADS
TOTAL DEMAND KVA 0 0 20 33 0 53
* *
PANEL DESCRIPTION ALL CIRCUIT BREAKERS SHALL BE SERIES
RATED FOR 65,000 AIC WITH MAIN CIRCUIT
BREAKER.
PROVIDE INTERNAL TRANSIENT VOLTAGE
SURGE SUPPRESSOR
AMPS 200 CONNECTED KVA 82.1 KVA
VOLTAGE 120/ 208 DEMAND KVA 52.8 KVA
PHASE 3PH 4W CONNECTED AMPS 228.1 AMPS
MAIN LUG ONLY 200 DEMAND AMPS 146.8 AMPS
FEED
AIC RATING
LOCATION
PANEL "PP1"
LOAD
LOAD, KVAO.C.P.
CKT PH CKT
O.C.P.LOAD, KVA
LOAD
LTG REC MTR HEAT A/C A P P A LTG REC MTR HEAT A/C
REC - 109, 1171.2 20 1 1 A 2 1 20 0.8 WALL REC - 122
REC - 117 1.4 20 1 3 B 4 1 20 0.8 WALL REC - 122
REC - 118 1.4 20 1 5 C 6 1 20 0.8 WALL REC - 122
REC - 118, 1191.2 20 1 7 A 8 1 20 0.8 WALL REC - 122
REC - 119 1.4 20 1 9 B 10 1 20 0.8 WALL REC - 122
REC - 120 1.4 20 1 11 C 12 1 20 0.6 CEILING REC - 122
REC - 121 1.4 20 1 13 A 14 1 20 0.6 CEILING REC - 122
REC - 120, 1211.2 20 1 15 B 16 1 20 0.6 CEILING REC - 122
REC - 116 0.8 20 1 17 C 18 1 20 1.4 WALL REC - 122
REC 111, 112, 114, 1150.8 20 1 19 A 20 1 20 1.0 WALL REC - 204
REC - 107 1.2 20 1 21 B 22 1 20 1.2 WALL REC - 204
REF - 107 1.0 20 1 23 C 24 1 20 0.8EWC, WALL REC -203
REF - 107 1.0 20 1 25 A 26
2 30 GENERATOR HEATER
REF - 107 1.0 20 1 27 B 28
REC - 105, 1060.8 20 1 29 C 30 1 20 BATTERY CHARGER
FL REC - 105 0.8 20 1 31 A 32 1 20 0.2 GENERATOR REC.
REC - 102 1.2 20 1 33 B 34 1 20 1.0 FUTURE FAN / TV
REC - 101, 1081.0 20 1 35 C 36 1 20 1.0 FUTURE FAN / TV
SP REC - 114 2.5 30 2
37 A 38 1 20 1.0 FUTURE FAN / TV
39 B 40 1 20 SPARE
REC - 114 1.2 20 1 41 C 42 1 20 SPARE
IT REC - 103 1.2 20 1 43 A 44 1 20 0.8REC - 123, 124
IC REC - 103 1.2 20 1 45 B 46 1 20 0.8 REC - 125
EX BUILDING REC 1.0 20 1 47 C 48 1 20 0.6 REC - 125
EX BUILDING REC 1.2 20 1 49 A 50 1 20 0.6 REC - 125
DISH - 107 2.6 30 2
51 B 52 1 20 0.6 REC - 125
53 C 54 1 20 0.6 REC - 125
OVEN - 107 3.8 40 2
55 A 56
2 20 2.3 EXTRACTOR
57 B 58
HOOD - 107 2.2 20 2
59 C 60
2 20 2.3 EXTRACTOR
61 A 62
CANOPY REC 1.6 20 1 63 B 64
2 20 1.6 DRYER
CANOPY REC 1.6 20 1 65 C 66
EXTRACT CONT 0.4 20 1 67 A 68 1 20 0.8 REC - 128
EXTRACT CONT 0.4 20 1 69 B 70 1 20 SPARE
REC - 126 0.6 20 1 71 C 72 1 20 SPARE
REC - 128 0.6 20 1 73 A 74
0.0 0.0 19.6 33.2 29.3COFFEE MAKER 1.5 20 1 75 B 76
SPARE 20 1 77 C 78
LP1 12.0 0.0 1.2 0.0 0.0 100 3
79 A 80
3 3081 B 82
83 C 84
ODD CIRCUIT CONNECTED, KVA
12 41 4 0 0 0 18 26 37 29 EVEN CIRCUIT CONNECTED KVA
ODD & EVEN CONNECTED KVA 12 59 30 37 29
DEMAND FACTOR 1.25 10+50% 1.0 1.0 0.0 * HEATING AND COOLING ARE NON-COINCIDENTAL LOADS
TOTAL DEMAND KVA 15 34 30 37 0 117PROVIDE 200A SUBFEED BREAKER FOR FUTURE SOLAR
* *
PANEL DESCRIPTION ALL CIRCUIT BREAKERS SHALL BE SERIES
RATED FOR 65,000 AIC WITH MAIN CIRCUIT
BREAKER.
PROVIDE INTERNAL TRANSIENT VOLTAGE
SURGE SUPPRESSOR
AMPS 600 CONNECTED KVA 167.5 KVA
VOLTAGE 120/ 208 DEMAND KVA 116.7 KVA
PHASE 3PH 4W CONNECTED AMPS 465.4 AMPS
MAIN CIRCUIT BREAKER 400 DEMAND AMPS 324.4 AMPS
FEED
AIC RATING
LOCATION 115
Cen
tral C
ount
y Fi
re &
Resc
ue -
Stat
ion
#5
St. C
harle
s, M
O
New
Fac
ility
For :
This drawing has been prepared in electronic format. Due to the potential that the electronic drawing file may be altered either intentionally or unintentionally by others, the information contained in
the original and revised printed sheets issued for construction must be considered superior to the electronic information. The electronic information is a component of the instruments of service, and
is only for the user's benefit for a specific use on this specific project. There is no representation of the suitability of the electronic information for other purposes, or the durability of the information,
or the medium through which the information is furnished. Any use for a purpose other than that for which the information is intended on this specific project shall be at the user's risk, without
liability or risk to the 303rd Engineering Group, LLC. The transfer of this electronic file does not transfer any license to use the underlying software or extinguish the rights of the 303rd Engineering
Group, LLC to reuse the information contained herein in the general course of a professional practice.
303rd Engineering Group, LLC
314-664-3382ST. LOUIS, MISSOURI 63118
1935 ARSENAL STREET
Illinois Professional Design Firm License No. 184.005110Project No. 77-2017
ORIGINAL SHEET SIZE: 30" x 42" PRINTED ON: February 7, 2018
CHARLES
KILGEN FIEDLER
062-054364
Exp 11 30 19 02 07 18
LIC
E
N
S
E
D
P
R
O
F
FESS
IO
N
A
L
E
N
G
I
N
E
ER
S
T
A
T
E
O
F I L
L
I
N
O
I
S