7” HORIZONTAL FLUORESCENT 7HF OPEN/...

10
SPECTRUM SILVER SERIES™ 994 Jefferson Street, Fall River, MA 02721 508.678.2303 FAX 508.678.2260 CAT. NO.: PROJECT: TYPE: www.speclight.com Dimensions shown are nominal. Spectrum Lighting is continually improving products and reserves the right to make changes that will not alter performance or appearance with or without written notice. CONE OF LIGHT DISTANCE FROM CEILING DIAMETER OF CIRCLE 1. SPECIFY FRAME 2. SPECIFY TRIM 3. FINISHED ORDER: EX EX DA1 DA2 DM7 DL1 DL2 -Electronic 120V/ 277V (Standard) -Advance Mark10™ dimming, 120V -Advance Mark 10™ powerline dimming, 277V -Advance MK7 -dimming, 120V thru 277V -Lutron ECO System 120V (min. dimming level 5%)¹ -Lutron ECO System 277V (min. dimming level 5%)¹ 7HF 7” HORIZONTAL FLUORESCENT OPEN/ LENS 2 x 26 WATT/ 1 x 42 WATT MAX • 7” horizontal lamp compact uorescent. • Available open, and lensed. • 20 gauge galvanized steel frame. 12” bar hangers expandable to 24” standard. • .0625 spun aluminum reector. • Junction box pre-wired, grounded. • Electronic ballast 120V/ 277V standard. • Ballast serviceable from the ceiling aperture. Suitable for use in damp location. Lensed xture has Wet Location option. • UL listed to standard No. 1598. SP7HF Spectrum Silver 7” Horizontal 2 QUAD 13 18 26 1 LAMP TT 13TT 18TT 26TT 32TT 42TT 132 SP7HF 7510 Open 2 Quad -Polished Flange -Black Flange -Black Micro Bafe -White Micro Bafe -Gasket SG CL GO HZ PW UM WE BL WH -Soft Glow -Clear Alzak -Gold Alzak -Haze -Pewter -Umber Alzak -Wheat Alzak -Black Finish -White Finish GS 7615 SG 7615 Open 1TT FRAME WATTS OPTIONS BALLAST OPEN TRIM # FINISH OPTIONS TRIM # SPLAY FINISH LENS/OPTIONS 7520 Lensed 2 Quad PG FG FL GL GS DO WL XB -Prismatic Glass lens (standard) -Frosted Glass -Fresnel Lens -Clear Glass lens -Gasket -Drop Opal -Wet Location 1-470 -Cross Blade Louver -White / White ange (standard) -Soft Glow/ White ange -Regressed Black bafe White ange -Regressed White bafe White ange -Polished Flange -Black Flange WS SGS RB RW PF BF 7620 WS PG 7620 Lensed 1TT 12.5 317.5 mm 6.5 165.1 mm 7.25 184.2 mm 8.5 215.9 mm SIDE VIEW TOP VIEW LENSED PF BF BB WB GS SP7H132EX/7620 RB GL 5.5 7.5 9.5 11.5 13.5 24 13 8 5 4 11.0 15.0 19.0 23.0 27.0 7615SG- Efciency: 71.7% Spacing: 1.55 EM FS PR RM BH27 TBC -Emergency battery pack (Specify Voltage) -Fuse Holder and Fuse -Plaster ring -Remodler housing -27” mounting bar -T-bar clip

Transcript of 7” HORIZONTAL FLUORESCENT 7HF OPEN/...

SPECTRUMSILVER SERIES™

994 Jefferson Street, Fall River, MA 02721 508.678.2303 FAX 508.678.2260

CAT. NO.:

PROJECT: TYPE:

w w w . s p e c l i g h t . c o m

Dimensions shown are nominal. Spectrum Lighting is continually improving products and reserves the right to make changes that will not alter performance or appearance with or without written notice.

CONE OF LIGHT

DISTA

NC

E FROM

CEILIN

G

DIA

METER O

F CIRC

LE

1. SPECIFY FRAME

2. SPECIFY TRIM

3. FINISHED ORDER:

EX

EX

DA1

DA2

DM7

DL1

DL2

-Electronic 120V/ 277V (Standard) -Advance Mark10™ dimming, 120V -Advance Mark 10™ powerline dimming, 277V-Advance MK7 -dimming, 120V thru 277V -Lutron ECO System 120V (min. dimming level 5%)¹ -Lutron ECO System 277V (min. dimming level 5%)¹

7HF7” HORIZONTAL FLUORESCENT OPEN/ LENS

2 x 26 WATT/ 1 x 42 WATT MAX

• 7” horizontal lamp compact fl uorescent. • Available open, and lensed.• 20 gauge galvanized steel frame.• 12” bar hangers expandable to 24” standard. • .0625 spun aluminum refl ector.• Junction box pre-wired, grounded.• Electronic ballast 120V/ 277V standard.• Ballast serviceable from the ceiling aperture.• Suitable for use in damp location. Lensed

fi xture has Wet Location option. • UL listed to standard No. 1598.

SP7HF Spectrum Silver 7” Horizontal

2 QUAD131826

1 LAMP TT13TT18TT26TT32TT42TT

132SP7HF

7510Open

2 Quad

-Polished Flange -Black Flange -Black Micro Baffl e -White Micro Baffl e -Gasket

SGCL

GOHZPWUMWEBL

WH

-Soft Glow -Clear Alzak -Gold Alzak -Haze -Pewter -Umber Alzak -Wheat Alzak -Black Finish -White Finish

GS7615 SG

7615Open

1TT

FRAME WATTS OPTIONSBALLAST

OPEN

TRIM # FINISH OPTIONS TRIM # SPLAY FINISH LENS/OPTIONS

7520Lensed2 Quad

PG

FGFL

GLGSDOWL

XB

-Prismatic Glass lens (standard) -Frosted Glass -Fresnel Lens -Clear Glass lens -Gasket -Drop Opal -Wet Location 1-470 -Cross Blade Louver

-White /White fl ange (standard) -Soft Glow/White fl ange -Regressed Black baffl e White fl ange -Regressed White baffl e White fl ange -Polished Flange -Black Flange

WS

SGS

RB

RW

PF

BF

7620 WS PG

7620Lensed

1TT

12.5317.5 mm

6.5165.1 mm

7.25184.2 mm

8.5215.9 mm

SIDE VIEW

TOP VIEW

LENSED

PF

BF

BB

WB

GS

SP7H132EX/7620 RB GL

5.5

7.5

9.5

11.5

13.5

24

13

8

5

4

11.0

15.0

19.0

23.0

27.0

7615SG-Effi ciency: 71.7% Spacing: 1.55

EM

FS

PRRM

BH27TBC

-Emergency battery pack (Specify Voltage) -Fuse Holder and Fuse -Plaster ring -Remodler housing -27” mounting bar -T-bar clip

2', 3', 4', 6', or 8'1 or 2 Lamp

T8 or T12

CONSTRUCTION/FINISH• Luminaires suitable for unit, row, surface, or suspension

mounting.• Multiple knockouts for convenient installation.• Heavy duty channel of code gauge die formed steel.• High reflectance white baked enamel finish.• Quarter turn latch secures channel cover for easy wireway

access.• See page 1119-S for strip reflectors.

ELECTRICAL• UL listed for direct mounting on low density ceilings and

damp locations.• Class P, HPF, CBM certified ballasts comply with Federal

Ballast Law (Public Law 100-357,1988).• Green grounding screw installed in channel.• Lampholders may be individually replaced or rewired.

STANDARD STRIP

JOB INFORMATION 1103.2-S

E

CATALOG NUMBER

T – Standard Strip(Rapid Start ) except 20

TL – Standard Strip(Trigger Start) 20 only

TT – Tandem “T” Series

FIXTURE FAMILY

––

17 – 17wT8 (24")20 – 20wT12 (24")25 – 25wT8 (36")30 – 30wT12 (36")32 – 32wT8 (48")40 – 40wT12 (48")CF40 – 40wTT5 (24")CF50 – 50wTT5 (24")CF55 – 55wTT5 (24")

LAMP TYPE/WATTAGE

See Section 1600-OA forOption Information.

See page 950-SS for MountingHardware.

OPTIONS

VOLTAGE

(not included)12

NO. OF LAMPSPER CROSS SECTION

• With generic Electronic Ballasts (Brand selected by Day-Brite) Suffix Catalog # with– Ballast Quantity – / -EB Lamps Per Ballast.

Example: –1/2-EB = One 2 Lamp Electronic Ballast. Example: –1/4-EB = One 4 Lamp Electronic Ballast (Available for T8 only)

NOTES:

120277347UNV – Universal voltage,

120-277 volt (witht8 or T5 electronicballast only)

STANDARD STRIP

DAY-BRITE LIGHTING776 South Green Street • Tupelo, Mississippi 38804 • PH: (662) 842-7212 • FAX: (662) 841-5501CANADIAN DIVISION189 Bullock Drive • Markham, Ontario L3P 1W4 • PH: (905) 294-9570 • FAX: (905) 294-9811

1103.2-S ©2006 DAY-BRITE LIGHTINGDB 03-06DAY-BRITE RESERVES THE RIGHT TO

MAKE CHANGES WITHOUT NOTICE.

DIMENSIONS DIM “A” Inches (mm)2' CHANNEL 24" (610 mm)3' CHANNEL 36" (914 mm)4' CHANNEL 48" (1219 mm)6' CHANNEL 72" (1829 mm)8' CHANNEL 96" (2438 mm)

1/2" DIA K.O. (2)

1/4" X 1/2" SLOTTED HOLE (4)

2" DIA K.O.

NOTE: 2' & 3' MODELS INCLUDE ONLY OUTBOARD DETAILS

3/16" STAND-OFFS

FUSE K.O.15/16" SQ. K.O.

7/8" DIA K.O. (8)

n 7/8" K.O. (2)8FT UNIT ONLY

24"

1 1/8"

7/8"

9"7 1/2"6 3/8"

8"6 3/8"

ÿ3/16 (4) ON 3-1/2 CIRCLE5 1/8"

6 3/8"

6"

4 5/8"4"

2 3/4" 4 1/8" [105 mm]

3 11/16" [93 mm]

4 1/8" [105 mm]

3 11/16" [93 mm]

NOTES:1.) 2" K.O. In center of channel is not present in 2' or 3' channel.

(9)

Fixture Size& # of Lamps

4'2-Lamp

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 f t-c 30 f t-c 50 f t-c 70 f t-c 100 ft-c

339 112 68 47 33220 73 44 31 –156 52 31 – –

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

1 95 90 85 90 86 82 78 752 85 77 70 81 74 67 67 623 77 67 59 73 64 57 59 52

4 70 59 50 67 56 48 51 455 64 51 43 61 49 41 45 386 58 46 37 55 44 36 40 33

7 54 41 32 51 39 31 36 298 49 36 28 47 35 27 32 259 45 33 25 43 31 24 29 22

10 42 30 22 40 28 21 26 20

CATALOG # T240 LAMPS = F40 INPUT WATTS = 84TEST #13900-1 S/MH=1.6 BALLAST = ESB BALLAST FACTOR = .94PHOTOMETRIC DATA

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture*

LIGHT LOSS FACTOR DATA

COEFFICIENT OF UTILIZATION

LIGHT DISTRIBUTIONLLF = 0.74 HPF Ballast LLF = LDD X LLD X BFLLF = 0.43 LPF Ballast LDD = Clean 0.93 Medium 0.89LLF = Light Loss Factor Dirty 0.85LDD= Luminaire Dirt Depreciation LLD = 0.88 @ 40% Rated Lamp Life

IES Category I Clean Annually B F = 0.94 HPF BallastLLD = Lamp Lumen Depreciation = 0.55 LPF BallastB F = Ballast Factor (commercial) Relamp @ 70% Lamp Life

ballast performance)

Angle End 45 Cross

0 1067 1067 10675 1061 1068 1071

15 1021 1074 1102

25 942 1061 112535 828 1025 112745 685 964 1091

55 515 865 101765 331 739 88275 155 571 722

85 26 359 49495 0 348 502

105 0 306 461

115 1 225 399125 0 174 324135 3 135 245

145 3 88 168155 6 48 96165 7 14 33175 7 5 8

n

50-50-20 Reflectances (Ceiling-Wall-Floor)n LLF = 0.74 3050 Lumens/Lamp Medium Dirtn Room width divided by room height = 5 or more, 2 or 1

=

DEGREES LUMENS % LAMP % FIXTURE

0-30 889. 14.6 15.60-40 1519. 24.9 26.70-60 2973. 48.7 52.20-90 4541. 74.4 79.7

90-180 1154. 18.9 20.30-180 5695. 93.4 100.0

LER = FS-66

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $3.64 BASED ON 3000 HRS. AND $.08 PER KWH.

CANDLEPOWER MAINTAINED ILLUMINATION TABLE- Square Feet/Fixture* COEFFICIENT OF UTILIZATION

AVERAGE LUMINANCE CD/SQ.M

WITH 2900 LUMEN LAMPS

TYPICAL V.C.P.’sRoom Mounting HeightSize Lengthwise Crosswise

Fixture Size& # of Lamps

2-Lamp32 watt

Room WidthRoom Height

521

Approx. Area (sq. ft.) per Fixture10 f t-c 30 f t-c 50 f t-c 70 f t-c 100 ft-c

- 130 78 56 39- 84 50 36 -- 59 36 - -

pfc 20pcc 80 70 50pw 70 50 30 70 50 30 50 30RCR

0 107 107 107 102 102 102 93 931 94 89 83 90 84 81 78 732 84 76 68 80 72 66 66 603 77 66 56 71 63 55 56 51

4 69 56 48 66 55 46 50 425 64 51 41 59 48 40 44 366 57 45 36 55 42 34 40 337 54 40 32 51 39 30 35 288 50 36 28 46 35 28 33 269 46 34 26 44 32 25 29 23

10 44 30 23 40 29 23 28 20

CATALOG # T232-1/2-EB LAMPS = F32T8 INPUT WATTS = 61TEST # 14719 S/MH=1.6 BALLAST = ELECTRONIC BALLAST FACTOR = .88PHOTOMETRIC DATA

Angle End 45 Cross

0 1019 1019 10195 1015 1018 1019

15 976 1009 1034

25 901 990 105935 793 958 105945 656 898 1019

55 494 800 95665 320 688 91175 154 590 718

85 28 308 43295 2 325 452

105 3 305 512

115 2 230 379125 2 160 334135 6 104 236

145 6 46 133155 7 5 42165 8 6 6175 9 5 6

ANGLE END 45° CROSS45 6257 6389 668655 5693 6243 673865 4843 6152 717175 3551 6404 662785 1448 4423 5003

n

80-50-20 Reflectances (Ceiling-Wall-Floor)n LLF = 0.75 2900 Lumens/Lamp Cleann Room width divided by room height = 5 or more, 2 or 1

=

8.5 10 8.5 1030x30 22 27 16 2040x40 19 22 14 1760x30 23 26 19 2360x60 17 19 13 14

100x100 17 18 12 13

DEGREES LUMENS % LAMP % FIXTURE

0-30 839 14.5 15.50-40 1429 24.6 26.40-60 2793 48.1 51.60-90 4316 74.4 79.8

90-180 1094 18.9 20.20-180 5410 93.3 100.0

LLF = .75 LLF = LIGHT LOSS FACTOR LLF = LDD X LLD X BF LDD = VERY CLEAN 0.94 CLEAN 0.90LLD = 0.91 @ 40% RATED LAMP LIFE BF = 0.88 ELECTRONIC BALLAST & T8 LAMP (RELAMP AT 70% LAMP LIFE)

*Observe Fixture S/MH Requirements for Specific Applications

LER = FS-78

COMPARATIVE YEARLY LIGHTING ENERGY COST PER 1000 LUMENS = $3.08 BASED ON 3000 HRS. AND $.08 PER KWH.

LIGHT DISTRIBUTION

FIXTURE EFFICIENCY= 93.4%

FIXTURE EFFICIENCY= 93.3%

a Genlyte company

Rev: 2017/01/06

Page 1VisaLighting.com800-788-VISA

OW1334 – AVATAR ™

The options available in this series provide a variety of visual compositions; this rugged die-cast and extruded fixture stands up to the elements.

L 36” (914 mm)D 4” (102 mm)W 7-1/4” (184 mm)MC 18” (457 mm)

VisaLighting.com/products/Avatar

5 Year WarrantyETL Listed

L

Accent Bar and End Cap

W

Frameand Perforation

DIMENSIONSDepth is measured from wall to front of fixture L = Length D = Depth W = Width MC = Mounting Center

XPSADA©Visa Lighting. Design Modification Rights Reserved.

OW1334

MODEL

Fill in shaded boxes using information listed belowOrder Code:

Type: Project:

🅐 SOURCE 🅔 OPTIONS🅑 VOLTAGE 🅒 FRAME / PERFORATION 🅓 ACCENT BAR AND END CAP

Finishes

Fluorescent Sources Voltage

2F39 39w long twin tube, 2G11 baseSelect MVOLT, 120V or 277V

2FS21 21w T-5, mini bi-pin base

MVOLT fixture accepts 120 through 277 input voltage

🅐 SOURCE – 🅑 VOLTAGE (Select one Source and Voltage)

Fusing, specify 120V or 277VHorizontal mount (vertical is standard)Remote emergency battery pack (damp location 50° F minimum)Express 10 day shipping

FUSEHMREMXPS

🅔 OPTIONS (Multiple Selections Allowed)

� Option availability may be interdependent with Voltage

FINISHES (Select one 🅒 Frame Finish and one 🅓 Accent Bar and End Cap Finish or Material) See page 2 for color chart

Pearl BeigeRustSungoldTraffic White

PB1035RUSTSUNGTW9016

Powder Coat Painted Finishes (Standard) for Frame or Accent Bar and End CapAgate GreyBronze MatteBronzeBlade Silver

AG7038BMATBRNZBSIL

Cove BlueCream WhiteGlimmerGraphite Silver

CVBLCW9001GLIMGSIL

Grey WhiteHeatherJet BlackOld Bronze

GW9002HTHRJB9005OBRZ

Metals (Premium) for Accent Bar and End Cap onlyBrushed Stainless SteelBSS Polished Stainless SteelPSS

Rev: 2017/01/06

VisaLighting.com800-788-VISA Page 2

OW1334 – AVATAR ™

Relative Scale Drawing

Door Height = 7'Ceiling Height = 9'Silhouette Height = 6'

This document contains information which is the property of Visa Lighting, and may not, in whole or in part, be duplicated, disclosed, or used for design or manufacturing purposes without the prior written permission of Visa Lighting. ©Visa Lighting. Design Modification Rights Reserved.

Traffic White (RAL9016)

TW9016Cream (RAL9001)

CW9001Grey White (RAL9002)

GW9002Jet Black (RAL9005)

JB9005

Painted Finishes (Standard)

Blade SilverBSIL

Graphite SilverGSIL

GlimmerGLIM

SungoldSUNG

BronzeBRNZ

Old BronzeOBRZ

Bronze MatteBMAT

Pearl Beige (RAL1035)

PB1035

Agate Grey (RAL7038)

AG7038HeatherHTHR

Cove BlueCVBL

RustRUST

Specify color code when ordering. For accurate color matching, individual paint and finish samples are available upon requestFor additional information see VisaLighting.com/materials-finishes

Photometrics

90˚

60˚

30˚

120˚

150˚

180˚

� High power factor electronic ballast, 0° F / -18° C starting temperature � Vertical mounting standard (horizontal mounting optional) � Mounts to standard electrical junction box (by others) and wall with provided hardware � Removable cam-action hinged frame for ease of maintenance � Extruded aluminum backplate and center accent, die-cast end caps. Solid metal or die cast accent.

� Sealed and gasketed construction � High impact white acrylic diffuser

w F1 rated, UV stable w UL-94 HB Flame Class rated

� No VOC powder coat paint or stainless steel finish � ETL listed for wet location mounting 4’ above grade

Technical Information

102 Trapezoidal Wedge (Standard Luminaire)102EM Emergency Sconce102EMR Remote Emergency Sconce

PREFIX DISTRIBUTION WATTAGE VOLTAGE FINISH OPTIONS

Enter the order code into the appropriate box above. Note: Philips Gardco reserves the right to refuse a configuration. Not all combinations and configurations are valid. Refer to notes below for exclusions and limitations. For questions or concerns, please consult the factory.

Refer to confiiguration chart below for available combinations.

LAMP / VOLTAGE CHART - 102

HID*

Voltage

120 208 240 277 347 480

• •• • • • •• • • • •

50CMHE1 UNIV

70CMHE1 UNIV

100CMHE1 UNIV

35HPS • 50HPS • • 70HPS • • • • • • 100HPS • • • • • • 150HPS • • • • •Fluorescent

26QF1 UNIV • 226QF1 UNIV • 32TRF1 UNIV • 42TRF1 UNIV •

CONFIGURATION CHART - 102EM5

Fluorescent

Distribution Voltage

FT WT MT 120 208 240 277 347 480

226QF2 • • • 32TRF • • • 42TRF • • •

CONFIGURATION CHART - 101EMR5

Fluorescent

Distribution Voltage

FT WT MT 120 208 240 277 347 480

226QF2,3,4 • • • 32TRF • • • 42TRF • • •

1. Fluorescent and CMHE luminaires feature electronic ballasts that accept 120V through 277V, 50hz to 60hz, input. Specify “UNIV” voltage for 120V through 277V.

option. 3. Available with ICE420 option, which powers two (2) lamps in emergency mode. ICE420 option only available with 226QF. CAUTION: Maximum battery pack input power for EMR units with ICE420 option is 100 watts (.83 amps) when heating element is on. This is in addition to the normal input power for luminaire lamps and ballast. 4. Available with I162 option, which powers two (2) lamps in emergency mode. Lamps are wired in parallel. In emergency mode, should one lamp become inoperable, the remaining lamp will operate with a minimum total initial output of 2,250 lumens. 5. Refer to “102 Emergency Sconce Table” on page 3 for additional information.

Job:Type: Notes:

100 Line102 Performance SconcePage 1 of 3

The Philips Gardco 102 Rounded Wedge high performance sconce offers an excellent alternative to unsightly wall mounted fixtures. These architecturally refined luminaires are designed to integrate naturally to wall surfaces. 102 luminaires are available with three (3) different distribution patterns - a wide throw, a medium throw and a forward throw. Each luminaire is designed to accept HID sources up to 100MH, and Compact Fluorescent sources up to 42 watt. Housings are sealed throughout, completely excluding moisture, dust, insects and contaminants.

102 luminaires installed in the normal downlight position, with a flat glass lens, provide full cutoff performance.

PREFIX DISTRIBUTION

WATTAGE AND VOLTAGE

* MH, CMHE and HPS types require medium based E17 lamps.

MH - Metal Halide 2. One (1) lamp is powered in emergency mode with EM and EMR types with the B84CG CMHE - Ceramic Metal Halide

with Electronic Ballast HPS - High Pressure Sodium TRF - Triple Tube Fluorescent QF - Quad Fluorescent

FT Forward Throw Not Available with Fluorescent or LPS sources.

WT Wide Throw Not Available with Fluorescent or LPS sources.

MT Medium Throw

Combinations marked with a dot, or shown with “UNIV” are available for ordering.

1611 Clovis Barker Road, San Marcos, TX 78666 (800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com© 2011 Koninklijke Philips Electronics N.V. All Rights Reserved. Philips Gardco reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.

79115-125/0317

50MH**

70MH**

100MH**

** All MH are pulse start by design, including CMHE types.

100 Line

1611 Clovis Barker Road, San Marcos, TX 78666 (800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com© 2011 Koninklijke Philips Electronics N.V. All Rights Reserved. Philips Gardco reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.

79115-125/0317

102 Performance SconcePage 2 of 3

6. 120V through 277V only7. Not available with 480V. Specify voltage.8. HID only, Not available with CMHE Ballasts, FT Optics or in 480V. 100

watt Quartz maximum (Provided by others).9. WT Optic only. 150w HID maximum, 100w Quartz maximum

(Provided by others).10. WT Optic only. 50CMHE or 70CMHE only. Supplied with

two (2) 20W MR16 or two (2) 35W MR16 Flood (40° beam) lamps. 11.Not available with WG or POLY options. Not available with EM

or EMR types.12.Rear entry permitted. 13.Not Available with WLU option.15. All Emergency Battery Packs for EMR types MUST be ordered with

luminaires and supplied by Philips Gardco. 16. CAUTION: Maximum battery pack input power for EMR units with

ICE420 option is 100 watts (.83 amps) when heating element is on. This is in addition to the normal input power for luminaire lamps and ballast.

17. Lamps are wired in parallel. In emergency mode, should one lamp become inoperable, the remaining lamp will operate with a minimum total initial output of 2,250 lumens.

18. WT Optic only. 50CMHE or 70CMHE only. Supplied with two (2) 6.2 watt, 300 lumen LED modules.

19. Requires a seperate source of 12V power by others.

FINISH OPTIONS

DIMENSIONS

Mounting Bolt Pattern

4 5/16"10.95 cm

3"7.62 cm

Mounting Plate

1 3/4" dia.4.4 cm

Note: Mounting plate center is located in the center of the luminaire width and 3.5"(8.89cm) above the luminaire bottom (lens down position). Splices must be made in the J-box (by others). Mounting plate must be secured by max. 5/16" (.79cm) diameter bolts (by others) structurally to the wall.

BRP Bronze PaintBLP Black PaintWP White PaintNP Natural Aluminum PaintBGP Beige PaintOC Optional Color Paint

Specify Optional Color or RAL ex: OC-LGP or OC-RAL7024.

SC Special PaintSpecify. Must supply color chip.

F6 FusingPCB7 Button Type PhotocontrolQS8 Quartz StandbyQST8 Quartz Standby - Timed DelayQ9249 Quartz EmergencyQT9249 Quartz Emergency - Timed DelayQ12V9,19 Quartz 12V EmergencyQ20MR10,19 (2)MR16 12V Emergency - 20 WattQ35MR10,19 (2)MR16 12V Emergency - 35 WattELED18,19 (2)LED 12V Emergency Modules - 6.2 WattSL Solite® Diffusing LensUT 5° UptiltWLU11 Wet Location Door for Inverted MountWS12 Wall Mounted Box for Surface ConduitWS/UT12 WS Option w/5° UptiltWG13 Wire Guard

EMR LUMINAIRES ONLY15

B84CG Bodine Remote Emergency PackICE42016 IOTA Remote Emergency Battery Pack

226QF only.116217 IOTA Remote Emergency Battery Pack

226QF only.

9"22.86 cm

16 1/2"41.91 cm

8 1/4"20.96 cm

GENERAL: Each Philips Gardco 102 luminaire is a wall mounted cutoff luminaire for high intensity discharge or compact fluorescent lamps. Internal components are totally enclosed in a rain-tight, dust-tight and corrosion resistant housing. The housing, back plate and door frame are diecast aluminum. A choice of three (3) optical systems is available. Luminaires are suitable for wet locations (damp locations if inverted).

HOUSING: Single-piece housings are die cast aluminum. A memory retentive gasket seals the housing with the doorframe to exclude moisture, dust, insects and pollutants from the optical system. A black, die cast ribbed backplate dissipates heat for longer lamp and ballast life.

DOOR FRAME: A single-piece die cast aluminum door frame integrates to the housing form. The door frame is hinged closed and secured to the housing with two (2) captive stainless steel fasteners. The heat and impact resistant 1/8” (.32cm) tempered glass lens and one-piece gasket are mechanically secured to the door frame with four (4) galvanized steel retainers.

OPTICAL SYSTEMS: Reflectors are composed of specular extruded and faceted components, electropolished, anodized and sealed. Reflector segments are set in arc tube image duplicating patterns to achieve the wide throw, forward throw or medium throw downlight distributions.

ELECTRICAL:

STANDARD LUMINAIRES: Each high power factor HID core and coil ballast is the separate component type, capable of providing reliable lamp starting down to -20°F/-29°C. Component-to-component wiring within the luminaire will carry no more than 80% of rated current and is listed by UL for use at 600 VAC at 302°F/150°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or higher.

Standard fluorescent units have a starting temperature of 0°F/-18°C. Standard fluorescent ballasts are high power factor electronic solid state.

LUMINAIRES FOR USE OUTSIDE NORTH AMERICA: Philips Gardco has capability to provide luminaires meeting requirements world wide. Consult the factory for specifications for projects outside North America.

LUMINAIRES with Q924 / G12V / QMR20 / QMR35 / ELED OPTIONS: Luminaires with the Q924 option require a separate source of 120V power (by others.) Luminaires with Q12V, Q20MR, Q35MR or ELED options require a separate source of 12V power (by others.)

EMERGENCY LUMINAIRES: All emergency luminaires feature an indicator light visible through the lens and a test switch accessible through the door assembly. Minimum battery pack ambient temperatures are as indicated in the 102 Emergency Sconce Table. In the event of a power interruption, emergency luminaires will power compact fluorescent lamps as indicated in the 102 Emergency Sconce Table at reduced light levels for a minimum of 90 minutes.

EMR LUMINAIRES include a 7.5’/2.29m, 12 wire, quick disconnect assembly for wiring through conduit (by others) to a B84CG, I162 or ICE420 fluorescent emergency battery pack. The fluorescent emergency battery pack MUST be supplied by Philips Gardco. The B84CG option, the I162 option or the ICE420 option is required on the order to the factory.

CAUTION: Maximum battery pack input power for EMR units with ICE420 option is 100 watts (.83 amps) when heating element is on. This is in addition to the normal input power for luminaire lamps and ballast.

LAMPHOLDER: Pulse rated medium base sockets are glazed porcelain with nickel plated screw shell. Fluorescent sockets are high temperature (PBT) with brass contacts.

FINISH: Each standard color luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) textured polyester powdercoat finish. Standard colors are as listed. Consult factory for specs on custom colors.

LABELS: All luminaires bear UL or CUL (where applicable) labels, except as noted. Lens down application is Wet Location and lens up is Damp Location. Emergency luminaires do not bear CUL label.

WARRANTY: 5 year limited warranty. See philips.com/luminaires for complete details and exclusions.

Page 3 of 3

100 Line102 Performance Sconce

SPECIFICATIONS

1611 Clovis Barker Road, San Marcos, TX 78666 (800) 227-0758 (512) 753-1000 FAX: (512) 753-7855 sitelighting.com© 2011 Koninklijke Philips Electronics N.V. All Rights Reserved. Philips Gardco reserves the right to change materials or modify the design of its product without notification as part of the company’s continuing product improvement program.

79115-125/0317

102 Emergency Sconce Table20

102 Emergency Luminaire

Battery Pack Min. Ambient Temperature

Lamps Powered in Emergency Mode

102EM (Integral) 32°F / 0°C (1) 26, (1) 32, or (1) 42 Watt Compact

Fluorescent Lamp102EMR (Remote) with

B84CG Option 32° F/ 0°C

102EMR (Remote) with I162 Option21 32° F/ 0°C (2) 26 Watt Compact

Fluorescent Lamps

102EMR (Remote) with ICE420 Option22 0°F / -18°C (2) 26 Watt Compact

Fluorescent Lamps

Notes:20. Contact Philips Gardco for emergency lumen output data.21. Lamps are wired in parallel. In emergency mode, should one lamp become inoperable,

the remaining lamp will operate with a minimum total initial output of 2,250 lumens. 22. CAUTION: Maximum battery pack input power for EMR units with ICE420 option is

100 watts (.83 amps) when heating element is on. This is in addition to the normal input power for luminaire lamps and ballast.

Diskuss LED Wall Light

CM-25400 05/13 page 1 of 2

© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.

Specifications are subject to change without notice.

www.philips.com/luminaires

PHILIPS CHLORIDE DISKUSS LED WALL LIGHT

The Philips Chloride Diskuss LED Wall Light is a slim architectural emergency or AC only die cast aluminum luminaire. Suitable for use indoors or outdoors, the Diskuss is ideal for retail, hotels, theatres, or other aesthetically sensitive areas.

Codes and standards

UL 1598 listed, UL 924 listed

UL wet location listing standard

NFPA 101, NEC, IBC, BOCA, and OSHA illumination

standard

ADA compliant

Construction

Fully-gasketed and powder-painted die cast aluminum

round housing with a round cover or optional square

cover with UV stabilized polycarbonate lens.

Tamperproof hardware is included standard.

Installation

Designed for direct mounting to a 3-1/2” octagonal, 4”

octagonal or single gang junction boxes using convenient

keyhole knockouts on the back housing.

The unit may also be connected to surface conduit by

means of the top-located conduit entry knockout.

All product variations include a dedicated normally on

input that allows for switching, dimming, photocell or

time clock control.

Lamps

Illumination is provided by two field-replaceable

white LED modules and a vacuum plated

polycarbonate reflector.

The two LED modules are independently driven and

operate at 3,100 K or 6,500 K based on selected models.

Battery

Maintenance free sealed nickel metal hydride with 10

year life.

Provides a minimum of 90 minutes

emergency illumination.

Warranty

Five full year on electronics and unit.

Electronics

120/277 VAC dual voltage input with surge protection is

standard on all models.

Self-powered models feature the Intelli-Charge circuit

where the charging system is microprocessor driven

with software embedded diagnostic routine and

temperature compensation.

Self-powered models include brownout detection, AC

lockout, low voltage disconnect, AC power indicator,

charge status indicator, audible user-interface controls,

visual LED system fault indicator, and tactile push-to-

test switch.

Additional equipment safety features include reverse

battery polarity detection and protection, and reverse

utility power detection and protection.

All self-powered models include an on-board IR receiver

for use with the optional hand-held remote (ICIR).

Offering a slim profile,

cleanaesthetics and reliability

Project:

Location:

Catalog No:

Fixture Type:

Mfg: Lamps: Qty:

Notes:

Ordering guide

Series Operation Housing Finish LED Designator Circuitry Options1

D IC

D Diskuss LED

Wall Light

A AC Only

N Self-Powered

Emergency

Unit with

Nickel Metal

Hydride

Battery

(NiMH)

W White

B Black

A Aluminum

G Gunmetal

BR Ornamental

Bronze

AC Aged Copper

VG Velvet Green

N Nickel

GA Granite

31K 3,100K

65K 6,500K

IC Intelli-Charge

Diagnostics

2CKT1 Two-Circuit 120/120 VAC (AC only models)

2CKT2 Two-Circuit 277/277 VAC (AC only models)

DC Universal 12-48 VDC Remote Emergency Input (AC only

models)

EX Special Input Transformer (specify voltage & frequency)1

HR Heater Option for -40°C to 40°C Ambient

T Self-Testing Diagnostics

TA Audible Self-Testing Diagnostics

TD Time Delay

SQ Square Front Cover

Footnotes:

1 Some option combinations may impact UL listing. Consult factory for specif ics.

Accessories:

ICIR – Intelli-Charge infra-red remote

T10TPTOOL – Tamperproof screwdriver

Intelli-Charge

Diskuss Diskuss Square

Diskuss Series

CM-25400 05/13 page 2 of 2

© 2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved.

Specifications are subject to change without notice.

www.philips.com/luminaires

Philips Lighting Company

200 Franklin Square Drive

Somerset, NJ 08873

Phone: 855-486-2216

Philips Lighting Company

281 Hillmount Road

Markham ON, Canada L6C 2S3

Phone: 800-668-9008

Electronics (continued)

Optional self-testing electronics - the diagnostic/charging

platform with optional self-testing mode automatically

runs a one minute self-test once a month and a 30 minute

test on the sixth and twelfth month in accordance with

NFPA 101.

A one minute or 90 minute test may be initiated via

the push to test switch on the unit or by activating the

appropriate test command on the optional IR test device.

Power Consumption –

AC-only models, standard wet location: -40°F (-40°C) to

104°F (40°C).

AC-only models, standard wet location w/ 2CKT option:

-40°F (-40°C) to 104°F (40°C).

Self-powered models, standard wet location:

32°F (0°C) to 104°F (40°C).

Self-powered models, standard wet location w/ heater

option: -40°F (-40°C) to 104°F (40°C).

AC only models: (120 VAC) 60 Hz, 0.203 A; (277 VAC) 60

Hz, 0.087A.

AC only, 2 circuit models: (120 VAC) 60 Hz,

0.203 A; (277 VAC) 60 Hz, 0.087 A.

Self-powered models without heater: (120 VAC)

60 Hz, 0.198 A; (277 VAC) 60 Hz, 0.088 A.

Self-powered models with heater: (120 VAC) 60 Hz, 0.366

A; (277 VAC) 60 Hz, 0.148 A.

Options

Available on AC only configured models to

accommodate inputs from a normally on circuit and an

AC emergency circuit from a generator or emergency

inverter circuit limited to 120 VAC circuits.

Available on AC only configured models to

accommodate inputs from a normally on circuit and an

AC emergency circuit from a generator or emergency

inverter circuit limited to 277 VAC circuits.

The DC option is reserved for AC only configured

models and accommodates wiring to a remote emergency

battery unit. The DC input is not polarity sensitive and

accepts 12 to 48 VDC from a remote source.

The special input transformer option allows for

input voltage and frequencies beyond the standard

120/277 VAC, 60 Hz input.

The heater option is available for self-powered

integral battery models for use in temperatures

ranging from -40°F to 104°F. The heater blanket

operation is microprocessor controlled for optimum

thermal management.

The self-testing option enables a periodic self-test

of the equipment where a test routine is established to

perform a one minute test every thirty days with a 30

minute test performed on the sixth and twelfth month in

accordance with NFPA 101. Equipment readiness faults

are indicated with a visual LED display.

The audible self-testing option enables a periodic

self-test of the equipment where a test routine is

established to perform a one-minute test every thirty

days with a 30 minute test performed on the sixth and

twelfth month in accordance with NFPA 101. Equipment

readiness faults are indicated with a visual LED display and

an audible alarm.

The time delay circuit causes the emergency lighting

equipment to remain under battery power for a period of

15 minutes after the utility power has been restored.

Dimensions

Performance

Meets Life Safety Code illumination standard; average of 1.0 FC, no point less than 0.1 FC, max to min

ratio of 40:1. Assumes open space with no obstructions, mounting height: 8' and reflectances: 80/50/20.

Analysis based on independently tested photometrics.

8 ft.

30 ft.

20 ft.

6 ft.

0.2 FC min.

1 FC min.

1 FC avg.

8 ft.

30 ft.

24 ft.

6 ft.

0.2 FC min.

1 FC min.

1 FC avg.

Test No.: ITL58893 Normal or Emergency Operation (AC Only and AC 2 Circuit)

Dual fixtures on 27’ centers, 8’ AFF, provide an average of

1 footcandle on a 5’ wide path.

Single fixture provides an average of 1 footcandle over

20 feet on a 6’ wide path.

Test No.: ITL58894Emergency Operation (Self-Powered)

Dual fixtures on 30’ centers, 8’ AFF, provide an average of

1 footcandle on a 6’ wide path.

Single fixture provides an average of 1 footcandle over

24 feet on a 6’ wide path.

AC Only Mode Emergency Mode

2.8"

(7.1cm)

3.6"

(9.14cm)

11.4"

(28.96cm)

0.8"

(2.03cm)

0.8"

(2.03cm)

.9" (2.29cm)

conduit entry

knockout

.9" (2.29cm)

conduit entry

knockout11.4"

(28.9cm)

11.4"

(28.9cm)