Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Collect fault information
Fault analysis
Fault locating
Troubleshooting
1 2 3 4
Troubleshooting procedure
Common methods to locate faults
Views of alarm, notification and operation log Analysis of status indicator Performance analysis Analysis of signaling tracing Analysis with instruments and meters Plugging/unplugging and pressing Isolation method Self-test method
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Platform faults
Database faults
Configuration and application faults
Alarm application faults
Performance application faults
1
2
3
4
5
NMS fault category
Troubleshooting guide of NMS faults
Client can not connect server NetNumen M31 server startup failure Database startup faults Failure of observing status attribute in dynamic
data management Failure of alarm box displaying audio/visual alarms Abnormal performance data report
Network between server and client is disconnectted
The client version differs from the server version
Language setting in deploy-gsmomcr01.properties and deploy-010muep.properties differs from that on the server
Disk is full
…
Use ping command to check whether the connection is OK
Use ipconfig and netstat commands to check whether server IP address configuration is proper
Check whether client version is consistent with server version
Check whether language setting is consistent with that in server
Use df –kh to check disk space
…Fault cause Troubleshooting
Client can not connect server
Server ini file doesn‘t have execution permission
Java virtual machine is not started successfully
Server profile is improperOracle database can not
start properly
…
Use ls –l to check whether the ini file has executable permission
Check whether compressed file under idk-solaris folder have been decompressed
Check whether the server configuration file is correct
Check whether it is successfully connected with Oracle database
Check whether database server name, IP address and hostname configured in tnsnames.ora are consistent with actual value
Use pkill -9 java to kill java process and restart the server
…Fault cause Troubleshooting
NetNumen M31 server startup failure
Database is already runningDtabase parameters are not
set correctly, which cause insufficient resources needed for startup
The system data file needed for startup is corrupt
Use data file is corrupt when the database is opened
…
Execute sqlplus sys/oracle@gomcr as sysdba to check whether Oracle can be connected
If the database does not properly start, check the returned result
Check whether the disk is full by using command df –k
If the database starts properly but cannot be connected, check whether the database monitor has started
…Fault cause Troubleshooting
Database startup faults
Communication between foreground and background is improper
Foreground and background data inconsistent
…
Check whether the communication link has been properly established between foreground and background
Do synchronization for whole table to keep consistence for foreground and background data
…Fault cause Troubleshooting
Failure of observing status attribute in dynamic data management
Probable reason is improper connection state in alarm box
…
Check the alarm box setting in NetNumen M31 alarm management, to check whether IP address/TCP port number of alarm box is consistent with actual value
Chek whether ping can get response from the network about alarm box, preventing from network cable or IP address conflict
Check whether the port number of alarm box has conflict with the port occupied by other processes
Check whether there are the setting for this alarm box on NMS server and communication state is OK
…Fault cause Troubleshooting
Failure of alarm box displaying audio/visual alarms
Link is disconnected between foreground and background
Performance file reported from foreground is improper or performace data has not stored yet
Nsf detect process is failed to connect foreground
…
Check physical link to ensure the foreground-background link is normal
After logging in SBCX board, switch to corresponding measurement types directory to view whether original performance data zip file for granularity is missing
check whether the data file for performance measurement is missing
Check nsf service state after logining OMP
Execute ps –ef | grep nsfdetect check whether nsfdetect process exists
View and print nsfdetect log
…Fault cause Troubleshooting
Abnormal performance data report
Alarm cases on NMS faults
After restarting iBSC OMP, background can not establish link with OMP
Software version cannot be synchronized to NE and system prompts FTP download failed
"License file invalid or missing" appears while configuring transceiver
Wrong time zone configuration causes performance report issue
NetNumen M31 upgrade fails
Fault analysis
The reason is IP address of O&M board is not consistent with that of OMP at background while configuring data.
Change OMP IP address at background. Restart OMP after synchronizing data, and the fault is solved.
Troubleshooting
After restarting iBSC OMP,background can not establish link with OMP
Fault analysis
The reason is ftp server IP in deploy-gsmomcr01.properties is inconsistent with that of IMP communication.
Modify ftpserver IP in deploy-gsmomcr01.properties and enable it consistent with IP address for IMP communication.
Troubleshooting
Software version cannot be synchronized to NE and system prompts FTP download failed
Fault analysis License file is invalid or missing.
Open Configuration Management view, License management appears in menu bar.
Click View License in License Management, and go to Update License interface.
Select the path to save license, find license.dat. license.dat file is located under ums-svr\deploy\runtime\,and click the Update button.
Troubleshooting
"License file invalid or missing" appears while configuring transceiver
Fault analysis
Time zone on client is not consistent with that on NetNumen(TM) M31 server. The system modifies the reported data according to time zone setting, so the time in performance report is not consistent with current time and performance data is displayed in two columns.
Querying whether performance data is proper after modifying time zone.
Troubleshooting
Wrong time zone configuration causes performance report issue
Fault analysis
After upgrade fails, check the server and input echo $OMCHOME command, null string is returned, not the value of $OMCHOME. From this, it is determined that the installation fault is caused by wrong $OMCHOME setting.
solaris has strict requirements on environment variable. The user shall not only modify /etc/profile file, also shall logout after performing /etc/profile command, and then use root user to login again.
After adding $OMCHOME value into /etc/profile file and making it effect, perform graphical installation process.
Troubleshooting
NetNumen M31 upgrade fails
Content
Overview NMS fault troubleshooting Data and software loading fault
troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Fault from data configuration
Fault caused by settings of software version
Category of data and software loading faults
Troubleshooting guide about data and software loading faults Mismatched board type and version configuration Version file does not exist Version file check error IPA resource unavailable NetNumen M31 data synchronization faults
Mismatch error between board version information configuration and board type causes impossible to download version
Board type configuration error
Access type error supported by the board
…
Check the version configuration and physical configuration of corresponding board, and correct corresponding errors
…Fault cause Troubleshooting
Mismatched board type and version configuration
Such a fault is usually caused by MP changeover or MP replacement
…
Check the data configuration to confirm whether the board configuration is correct
Wait for a period of time (more than 15 minutes) and then check whether the board is running properly
In software management on NMS, perform NE synchronization action for software, and upload the version file to OMP
…Fault cause Troubleshooting
Version file does not exist
The check error on the reception end often results from the version file error occurred during the transmission
…
Download the version again from the server
Contact the local ZTE office for the version file
…Fault cause Troubleshooting
Version file check error
Data configuration of user plane IP is different from that for MSC and BSC
AIPB board goes faultyDSP port configuration is
incorrect on AIPBIPA resource is blocked
manually
…
Check whether data configuration is consistent for MSC and iBSC and the address on user plane shall be connected
View IPA resource state; view the state of AIPB board and DSP
Check whether the ports correspond to DSP are correct
Check whether IPA resource is blocked manually
…Fault cause Troubleshooting
IPA resource unavailable
The link between NetNumen M31 and iBSC is disconnected
iBSC is performing writing action for previous data synchronization
…
Check whether the link between NetNumen M31 and iBSC is normal by Ping packets
Retry after waiting for a certain duration, and wait for the completion of writing action on previous synchronization
…Fault cause Troubleshooting
NetNumen M31 data synchronization faults
Fault analysis
Disconnected communication between server and OMP
OMP doesn't add FTP user; while trying to login OMP through FTP, it is found that zte/zte can't login
Normal communication between server and OMP
After logging into foreground OMP through zte/zte and adding users by addFtpUserInfo "zte","zte",3,3,0, it can synchronize with foreground
Troubleshooting
-------iBSC data failed to synchronize and download to NE
Alarm case on data and software loading faults
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Faulty physical transmission
Signaling faults
Trunkline fault at interface A
Fault caused by wrong data configuration
1
2
3
4
Category of connection faults at interface A
Troubleshooting Guide about Connection Faults at Interface A
Unstable No. 7 signaling BSC can not PING virtual address at interface A
successfully Synchronization fault at interface address Office is available and BSC message can't reach
MSC server
Transmission problems, including high bit error ratio of transmission equipments and bad contact of connectors
The fault is possibly due to message overflow resulting from high signaling load
…
Check whether connections are reliable. Test the bit error ratio of transmission
Check the signaling link load through performance measurement. Expand the link if the load is too high
…Fault cause Troubleshooting
Unstable No. 7 signaling
This is caused by inconsistent ARP entries between MAC address of BSC interface board and virtual IP address at interface A in MSC Server NE
…
Manually clear wrong MAC or reset BSC IPI interface board
…Fault cause Troubleshooting
BSC can not PING virtual address at interface A successfully
Print all interface information on RPU, it is found that IPI interface is UP and another interface is configured as unknown unit interface address for IPI, its state is DOWN. Through analysis, it is acknowledged that old data is not deleted completely, leading to interface address incorrectly synchronized to interface board
…
Delete ZDB file on RPU and restart it
…Fault cause Troubleshooting
Synchronization fault at interface address
SI0 location is inaccurate, the message transferred from exchange domain by BSC is implemented by keywords record in index SI0 location. If SI0 location is inaccurate, BSC may discard relevant messages
Network appearance configuration of BSC is inconsistent with that of MSC Server
…
Use NetNumen M31 client to view whether "Original point code" that configures "SIO location" at interface A is correct
Use NetNumen M31 client to view whether "network appearance" that configures "local office point" is consistent with network appearance setting on MSC Server. If inconsistent, you shall modify it to be consistent
…Fault cause Troubleshooting
Office is available and BSC message can't reach MSC server
Fault analysis
Check process parameters on application server for local office point in background configuration management, "Application property" is configured as "server"; verify it with the engineer at CN side, this property for MSC Server is also configured as “server", if the settings for both parties are same, coupling is impossible to connect
After changing "application property" on application server at BSC side to "Client", the problem is solved
Troubleshooting
Coupling disconnection due to data configurationAlarm case on connection faults at interface A
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb
interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Faults caused by data configuration: such as wrong data configuration at Gb port
Fault caused by hardware problem: such as GIPB board damaged
Category of Connection Faults at Interface Gb
Troubleshooting guide about connection Faults at interface Gb
Cannot ping iBSC successfully Cannot ping SGSN successfully
Subnet mask is not configured as 255.255.255.255 while configuring iBSC virtual address
Cross-network virtual address with iBSC, no static route or wrong static route configuration
IPGB board uses wrong network ports
…
Configure RPU subnet mask for iBSC virtual address as 255.255.255.255 for interface configuration in IP related configuration
Correctly configure static routeMake network ports used by
backplane of IPGB board matched with the ones which setting in NetNumen M31
…Fault cause Troubleshooting
Cannot ping iBSC successfully
Configuration incompleteSubnet mask is not
configured as 255.255.255.255 while configuring SGSN virtual address
Cross-network virtual address with SGSN, no static route or wrong static route configuration
…
Port, loopback address, NSEI, local and remote IP port, and NSVC shall be configured in order
Configure subnet mask for loopback address as 255.255.255.255 for interface configuration in protocol stack configuration
Correctly configure static route in NetNumen M31
…Fault cause Troubleshooting
Cannot ping SGSN successfully
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
System fault
Interconnected board link faults
Startup faults
External interface link faults
Environmental faults
Clock faults
System faults
Fault analysis
It is found that OMP module type is configured as OMP and RPU. MP type is selected as OMP_SMP_CMP while creating OMP version of ini file
Re-create OMP version of ini file and select its MP type as OMP for later solution
Troubleshooting
-------Instance of OMP restarting repeatedlyAlarm Case on board faults
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Category of CS service faults
Number Category of CS service faults
1 Access faults Fault caused by frequent location update
Faults of service failure
QoS fault
2 Handover faults
3 Congestion faults Ground resource congestion
Wireless resource congestion
4 Call drop faults Call drop due to hardware problem
Call drop due to data configuration and optimization
5 Voice faults Faults from wireless environment
Faults from data configuration
Faults from hardware issues
When MS is powered on, it finds the network and performs a location update
MS performs location update periodically
MS is moved to a new location area
…
It needs to determine whether location areas are too small, and plan the location areas again if necessary
It needs to adjust the radio coverage range, and if possible, increase the minimum access level of the cell
Cooperate with MSC to modify the value of timer T3212
…Fault cause Troubleshooting
-------Frequent Location Update
Troubleshooting guide about access faults(1)
BSC provides many ways for the high priority subscriber to occupy resource first, which includes reserving a few TCH/F for high priority subscribers, and making the low priority subscriber handover to adjacent cell. The fault that call fails even for a high priority subscriber indicates the above measures are not taken effectively
…
In Other property of Cell params, open Use cell EMLPP threshold to configure some reserved channel for high-priority user, and set Reserved rate of eMLPP to configure user priority threshold of reserved channel
Enable the cell parameters of allowing forced handover and allowing forced disconnection in Service process additional params
…Fault cause Troubleshooting
-------Problem about High Priority Subscriber AccessTroubleshooting guide about access faults(2)
Fault analysis
By signaling trace SCCP protocol, it is found that unmatched encryption algorithm is prompted in connection error
We verify and confirm with core network side that A5/1 voice encryption algorithm is opened and default iBSC parameters are closed
After modifying and using A5/1 encryption in Other property, the call is restored
Troubleshooting
-------Call disconnection due to different voice encryption modes at core network and radio ride
Alarm Case on access faults
The handover failure of radio interface is related to the radio quality of the handover-in cell, for example, the handover-in cell has severe interference, hardware fault, or failure of obtaining the timing advance
…
Find out towards which cell the handover failure ratio is high
Check whether the handover-in cell with handover failure has hardware faults in some carriers, improper power, or high assignment failure ratio
Check whether the handover-in cell with handover failure has interference
Check whether MARGIN settings for handover threshold window, slide window, and adjacent window are reasonable
Check whether the adjacent relation is correct
…Fault cause Troubleshooting
-------High Ratio of Handover FaultsTroubleshooting guide about handover faults
The location areas are too small
Burst traffic (short messages for example) causes SDCCH congestion
The traffic is too heavy and too few SDCCHs are configured
Hardware fault of the carrier causes SDCCH congestion
Interference on the radio interface causes congestion
Periodical location updating timer T3212 timeout is too short
…
Adjust the location area sizeEnable the SDCCH dynamic
conversion functionIncrease the number of SDCCHs in
configurationSet MAX number of re-transmitting
events times to reduce the number of random access retransmitted by MS
Troubleshoot the hardware fault or replace the carrier to restore the number of available SDCCHs
Check whether there is any TCH carrier with the same frequency and same color code as those of BCCH nearby
…Fault cause Troubleshooting
-------SDCCH congestionTroubleshooting guide about congestion faults(1)
By creating Performance Statistics at MAC Port and Performance Statistics at IP Port in background performance management, view transmitting & receiving bytes, its average rate, transmitted & received packet number, and discarded packet number
View resource occupancy condition in IPA Management dynamically managed from background BSC data
…
Add IPI boardAdd AIPB board
…Fault cause Troubleshooting
-------IPA resource congestionTroubleshooting guide about congestion faults(2)
Interference includes co-channel interference and adjacent-channel interference. When MS receives strong co-channel or adjacent-channel interference signals in the service cell, the signal quality degrades, which makes MS unable to accurately demodulate the BSIC of the adjacent cells or makes BTS unable to correctly receive the MS measurement report, thus the call quality becomes worse and call drop occurs
…
Interference can be avoided by modifying the BTS transmission power, downtilt of the antenna, or the frequency point plan of the cell concerned
Use DTX, frequency-hopping technology, power control, and diversity
Adjust the intra-cell handover parameters relevant with interference
Adjust the handover threshold and cell reselection parameters to lower the cell traffic
…Fault cause Troubleshooting
-------Call drop due to interfaceTroubleshooting guide about call drop faults
Echo suppressor fault or a few trunks not connecting echo suppressors may all cause the echo problem
The fault may be due to MS problems
The fault may be due to BTS hardware problems
The self loop of a few A-interface circuits or inter-office trunks will cause that only one’s own echo can be heard and the opposite party’s voice can not be heard
…
Ensure whether the fault exists only in a few MSs
Check whether the trunk self loop exists
Check whether the echo suppressor of MSC works properly
Decide which hardware of BTS is related to the fault through dialing test and signaling tracing, and replace relevant faulty hardware
…Fault cause Troubleshooting
-------Echo problemTroubleshooting guide about voice faults
Content
Overview NMS fault troubleshooting Data and software loading fault troubleshooting Connection fault troubleshooting at A interface Connection fault troubleshooting at Gb interface Hardware fault troubleshooting CS service fault troubleshooting PS service fault troubleshooting
Insufficient radio channelInsufficient Abis transmission
resourcePoor UPPB DSP resource
…
Adjust wireless channel configuration and add PDCH channels
Add transmission at AbisAdjust UPPB DSP or add UPPB
boar
…Fault cause Troubleshooting
-------PDCH allocation faultsTroubleshooting guide about PS service faults(1)
Network of the computer connected to MS isn’t installed correctly
The dial-up network setting is incorrect
GPRS parameter setting of the MS is incorrect
…
Ensure the dial-up network is correctly installed in the network properties
Check the dial-up network setting to ensure the data configurations (such as port number, rate setting etc) are correct
Ensure the data configurations (such as APN, gateway setting) of MS are correct
…Fault cause Troubleshooting
-------MS PDP activation faultsTroubleshooting guide about PS service faults(2)