7 Coatings - Best Materials · 2.repair voids and delaminated areas with BaSF branded cementitious...
Transcript of 7 Coatings - Best Materials · 2.repair voids and delaminated areas with BaSF branded cementitious...
VOC COntent•MasterSealM200:
–Self-levelinggrade:196g/Llesswaterandexemptsolvents
–Flash/slopegrade:203.3g/Llesswaterandexemptsolvents
•MasterSealTC225:209g/Llesswaterandexemptsolvents.
Polyurethane waterproofing, traffic-bearing membrane systems for vehicular and pedestrian areasForMerLySonoguard®
071800traffic Coatings7
PRODUCt HIGHLIGHtS•Primercoatnottypicallyrequiredwhichhelpstoreducelaborandmaterialcosts
•Waterproofwhichhelpstoprotectconcretefromfreeze/thawdamage;protectsoccupiedareasbelowfromwaterdamage
•excellentchlorideresistanceprovidesprotectionagainstchlorideintrusion;extendsthelifeofreinforcingsteel
•Seamlesselastomericmembraneoffersexcellentdurabilityandsuperiorabrasionresistance,hasnoseamsthatmayresultinleaks
•Skidresistanttoincreasesafety•Multiplesystemsavailable,makingMasterSealTraffic1500idealforvariousvehicularorpedestriantrafficsolutions
•repairableandrecoatabletoextendtheusefullifeofthesystem
MasterSeal® Traffic 1500
DeSCRIPtIOnMasterSealTraffic1500waterproofingsystemsarecomposedof:
–MasterSealM200,aone-component,moisture-curingpolyurethane,–MasterSealTC225,aone-componentaliphaticmoisture-curingpolyurethane,–MasterSealTC225TintBase,consistingof40standardcolors,(seeFormno.1017936).
Forprojectsrequiringprimer,twochoicesareavailable:–MasterSealP222,aone-componentsolvent-basedprimerandsealer,–MasterSealP220,atwo-componentwaterborneepoxyprimerandsealer.
PaCkaGInG- MasterSealP222:5gallon(18.93L)pails
- MasterSealP220:4gallon(15.14L)unitsin5gallonpails(18.93L)
- MasterSealM200,(self-levelingandslope-grade):- 5gallon(18.93L)pails-55gallon(208L)drums
-MasterSealTC225:-5gallon(18.93L)pails-55gallon(208L)drums
-MasterSeal914:1pint(473mL)cans-MasterSeal915(forrecoatapplications):0.5pint(236mL)cans
YIeLD Seechartonpage3
COLORS gray,Charcoal,Tan
StORaGe Storeinunopenedcontainersinacool,clean,dryarea
SHeLf LIfe- MasterSealM200andTC225: 5galpails,1yearwhenproperlystored 55galdrums,9monthswhenproperlystored
-MasterSeal914,pintcans:2yearswhenproperlystored
-MasterSeal915:1yearwhenproperlystored
MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us
Technical Data Guide
technical Data CompositionMasterSealTraffic1500isamoisture-curingpolyurethanemembrane.
Compliances•uL790ClassaFirerating•aSTMC957•aSTMe108•aSTMe84
Weight per gallon, lbs(kg) 9.9(4.5) 9.1(4.1) aSTMd1475
Specific gravity, kg/L 1.19 1.09
Solids aSTMd1259 Byweight,% 84 77 Byvolume,% 81 75
Viscosity, cps 4,000–9,000 2,000–4,000 aSTMd2393
flash Point, °F(°C) 104(40) 105(40.5) aSTMd56
*uncuredmaterial
Hardness, Shorea 60 89 aSTMd2240
tensile strength, psi(MPa) 752(5.2) 2,500(17.2) aSTMd412
elongation, % 595 502 aSTMd412
tear strength, PIT 74 199 aSTMd1004
Weight loss, % 16 17 Max:40
Low temperature flexibility noCracking noCracking noCrackingand crack bridging
adhesion in peel after water immersion,pli, Primedmortar 43 n/a 5 Plywood 34 n/a 5
adhesion (Pull-off), psi BaseCoat 275 aSTMd4541
ethylene glycol 88 92 Min:70
Mineral spirits 47 60 Min:45
Water 96 83 Min:70
Testresultsareaveragesobtainedunderlaboratoryconditions.reasonablevariationscanbeexpected.
elongation recovery, % 94 Min:90
tensile retention,% 151 Min:80
elongation retention, % 94 Min:90
abrasion resistance,mglost;(aSTMd4060) 1—systempasses Max:50CS-17Wheel,1,000gload,1,000cycles
Crack bridging, 1,000cycles Systempasses —
test Data
ProPerTy* reSuLTS TeSTMeThod
M200 TC225
ProPerTy reSuLTS TeSTMeThod/
M200 TC225 requIreMenTS
CheMICaL reSuLTS requIreMenTS
M200 TC225
CheMICaL reSuLTS requIreMenTS
DECK COATING VALIDATION
Issued to: BASF Corp.Product: Sonoguard Base Coat & Sonoguard Top Coat
ASTM D 412: Tensile Strength of Top Coat Sonoguard Top Coat Tensile Strength: 2,707 psi; Elongation: 699%
ASTM D 4541: Adhesion of Base Coat Sonoguard Base Coat Pull-off Adhesion: 539 psi
ASTM D 4060: Abrasion Resistance of Top Coat Sonoguard Top CoatAbrasion Resistance: .30 mgms loss – mgms loss/1,000 cycles
Validation Date: 3/7/13 – 3/6/18
No. 313-SON318 Copyright © 2013
ProPerTIeSoFCuredMeMBraneS
CheMICaLreSISTanCeTenSILereTenTIon(aSTMC957)
MaSTerSeaLTraFFIC1500SySTeMWeaTherIngreSISTanCeandeLongaTIonreCovery(aSTMC957)
TechnicaldataguideMasterSeal® traffic 1500
Weight per gallon, lbs(kg) 9.9(4.5) 9.1(4.1) aSTMd1475
Base coat Wetmils(mm) 25(0.6) 25(0.6) 25(0.6) drymils(mm) 20(0.5) 20(0.5) 20(0.5) Coverage1 60(1.5) 60(1.5) 60(1.5)
Mid coat Wetmils(mm) none 20(0.5) 25(0.6) drymils(mm) none 15(0.4) 20(0.5) Coverage1 none 80(2.0) 60(1.5)
finish coat Wetmils(mm) 25(0.6) 20(0.5) 20(0.5) drymils(mm) 20(0.5) 15(0.4) 15(0.4) Coverage1 60(1.5) 80(2.0) 80(2.0)
aggregate2 lbsper100ft2 10–15 30–50 50–70 (kg/m2) (0.5–0.7) (1.5–2.5) (2.5–3.4)
Coverageratesareapproximateandmayvaryduetotheapplicationtechniqueused.actualcoverageratewillalsodependonfinishandporosityofthesubstrate.1Coverageisft2/gal(m2/L)2(16–30meshroundedsilicasandorproportionalequivalent)
2.dynamiccracksandjoints1⁄16"(1.6mm)andgreaterwidemustberoutedtoaminimumof1/4by1/4"(6by6mm)andcleaned.Installbondbreakertapetopreventadhesionofsealantstothebottomofjoint.PrimejointfacesonlywithMasterSealP173(seeFormno.1017962).Filljointsdeeperthan1/4"(6mm)withappropriatebackerrodandMasterSealSL1™/SL2™(slopegradeorself-leveling)orMasterSealnP1™/nP2™sealants(seeFormnos.1017903and1017911).Forcracks,sealantshouldbeflushwiththeadjacentconcretesurface.Forexpansionjoints,sealantshouldbeslightlyconcave.
3.Sealedjoints1"(25mm)orlesscanbecoatedoverwithMasterSealTraffic1500.expansionjointsexceeding1"(25mm)wideshouldnotbecoatedoverwithMasterSealTraffic1500sothattheycanperformindependentlyofthedeckcoatingsystem.
test Data, cont.
2.repairvoidsanddelaminatedareaswithBaSFbrandedcementitiousandepoxypatchingmaterials.Forapplicationwhenfast-turnrepairsarerequired,MasterSealM265canbeusedtorepairpatchesupto1"(25mm)indepth.PleaserefertoTechnicalServiceforproperapplicationtechniques.
3.allunitsmustbeappliedwithinthespecifiedpotlife.
SurFaCePre-STrIPInganddeTaILIng1.Fornonmovingjointsandcrackslessthan1⁄16"(1.6mm)wide,applyprimerwhenrequired,followedby25wetmils(0.6mm)pre-stripingofMasterSealM200.MasterSealM200mustbeappliedtofillandoverlapthejointorcrack3"(76mm)oneachside.Feathertheedges.
HOW tO aPPLYSURfaCe PRePaRatIOnConCreTe
1.Concretemustbefullycured(28days),structurallysound,cleananddry(aSTMd4263).allconcretesurfaces(newandold)mustbeshotblastedtoremovepreviouscoatings,laitanceandallmiscellaneoussurfacecontaminationandtoprovideprofileforproperadhesion.abrasiveshotblastingmustoccurafterconcreterepairhastakenplace.acid-etchingisnotpermitted.ProperprofileshouldbeaminimumofICrICSP-3(asdescribedinICrIdocument03732.)
LIghTToMedIuM heavyduTy exTraheavyduTy
TraFFIC&PedeSTrIan (reFuSaLMeThod) (reFuSaLMeThod)
InDUStRIeS/SeCtORS•Stadiums•Balconies•Parkinggarages•CommercialConstruction•Buildingandrestoration
MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us
4.Cuta1/4by1/4"(6by6mm)keywayintotheconcretewherethecoatingsystemwillbeterminatedifnowall,joint,orotherappropriatebreakexists.Fillaccordingtoinstructionsoncracksandjointsover1⁄16"(1.6mm)wide.
5.Formasealantcantintothecorneratthejunctionofallhorizontalandverticalsurfaces(wallsections,curbs,columns).PrimewithMasterSealP173andapplya1/2–1"(13–25mm)widebeadofMasterSealnP1orMasterSealnP2sealants.Tooltoforma45°cant.
6.Inlocationsofpotentialhighmovement,suchaswallandslabintersections,apply25wetmils(0.6mm)ofMasterSealM200andembedMasterSeal955.
MeTaLSurFaCeS1.removedust,debris,andanyothercontaminantsfromvent,drain-pipeandpostpenetrations,regletsandothermetalsurfaces.
2.CleanthesesurfacestobrightmetalandprimeimmediatelywithMasterSealP173.
3.ProvideappropriatecantwithMasterSealnP1,nP2orCr195sealanttoeliminate90°angles.
PLyWood1.allplywoodmustbesmooth-faced,aPa-stampedandexteriorgrade.Constructionmustconformtocode,butplywoodmustnotbelessthan15⁄32"
(12mm)thick.Plywoodspacingand
deckconstructionmustfollowaPaguidelines.2.Surfacesmustbefreeofcontaminants.Primingisnotnecessaryonclean,dryplywood.
3.allseamsmustbecaulkedwithMasterSealnP1orMasterSealnP2sealants(seeFormnos.1017906and1017911).Pre-stripe4–6"(102–152mm)widewith25wetmils(0.6mm)ofM200.reinforceallseamsbetweenplywoodsheetsandbetweenflashingandtheplywooddeckbyembeddingMasterSeal995intothepre-striping.
aPPLICatIOn Of PRIMeRPrimernoTe:Whenprimerisrequiredonajob,followthesesteps.WhenapplyingTraffic1500withoutusingaprimer,proceedtoapplication.
1.afterthoroughlyvacuumingthesurface,applyMasterSealP222orP220toalltheproperlyprepareddecksurfacesattherateof200–250ft2/gal(4.9–6.1m2/L).usingarollerpanandashort-tomedium-naprollercover,forcetheprimerintoporesandvoidstoeliminatepinholes.donotapplyoverpre-striping.useonlysolvent-resistanttoolsandequipment.
2.allowprimertodryuntiltack-free.M200mustbeappliedthesameworkingday.
MaSTerSeaLM2001.allpreparatoryworkmustbecompletedbeforeapplicationbegins.Becertainthesubstrateisclean,dry,stableandproperlyprofiled.Sealantsandpre-stripingshouldbeproperlycured.applythebase,midandfinishcoatswithaproperlysizedsqueegeetoarriveattherequiredmilthicknesses.
2.Thebestmethodtoensuretheproperwetfilmthicknessistheuseofagridsystem.dividethesurfacetobecoatedintogridsandcalculatethesquarefootageofeach.refertothecoveragecharttodeterminethequantityofMasterSealTraffic1500neededforeachgridtoarriveattherequiredmilthicknesses.Forexample,onepailofMasterSealM200willcoveranareaapproximately300ft2(28m2),oragrid30by10ft(9by3m)at25wetmils(0.6mm).Themilthicknessofallcoatscanalsobeverifiedbytheuseofawet-milthicknessgauge.
3.applyMasterSealM20025wetmilsthick(0.6mm)usingapropernotchedsqueegeetoentiredecksurface,andbackroll,overcoatingtheproperlypreparedcracks,jointsandflashings.Forslopedareas,useslope-gradeMasterSealM200.donotcoatexpansionjointsover1"(25mm)wide.
4.allowcuringtimeofovernight(16hourminimum).Slightlyextendthecuringtimeincoolordryweatherconditions.ThesurfaceofMasterSealM200shouldhaveaslighttack.Ifthecoatinghasbeenexposedforaprolongedperiod,consultTechnicalServiceforrecommendations.
aPPLICatIOn MetHODS Of SYSteMSMasterSealTraffic1500canbeinstalledinseveralconfigurations,dependinguponthedegreeoftraffictowhichthesystemisexposed.Inareasofextremetraffic(turninglanes,paybooths,entrancesandexits),applytheextraheavy-dutyTrafficSystem.Thefollowingsummarybrieflydescribeseachconfiguration.allcoverageratesareapproximate.
LIghT-ToMedIuM-duTyTraFFIC&PedeSTrIanSySTeM
1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.
3.apply25wetmils(0.6mm)MasterSealTC225usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealTC225material.Whilethecoatingisstillwet,broadcastMasterSeal941orequivalent16–30roundedsilicasandat10–15lbs/100ft2(0.5–0.7kg/m2),thenbackrollintothecoatingtofullyencapsulate.
heavy-duTyTraFFICSySTeM1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.
3.apply20wetmils(0.5mm)MasterSealTC225usinganotchedsqueegeeat80ft2/gallon(2.0m2/L).ImmediatelybackrolltolevelMasterSealTC225.Thenextstep,#4,canutilizeeithermethoddescribedin4aor4B.
TechnicaldataguideMasterSeal® traffic 1500
5.removealllooseaggregate,thenapply20wetmils(0.5mm)MasterSealTC225usingaflatsqueegeeat80ft2/gallon(2.0m2/L).ImmediatelybackrolltoevenlylevelMasterSealTC225.
6.Foradditionalslipresistance,immediatelybroadcastMasterSeal941orequivalentatarateof7–10lbsper100ft2(.34–.49kg/m2)andbackrolltoencapsulate.
MOCkUPProvidemockupofatleast100ft2(9.3m2)toincludesurfaceprofile,sealantjoint,crack,flashingandjuncturedetailsandallowforevaluationofslipresistanceandappearanceofMasterSealTraffic1500system.
1.Installmockupwithspecifiedcoatingtypesandwithothercomponentsnoted.
2.Locatewheredirectedbyarchitect.3.Mockupmayremainaspartofworkifacceptabletoarchitect.Forrecoatapplications,seeMasterSealTraffic1500technicalbulletin#24.
CURInG tIMeallowcuringtimeof72hoursbeforevehicularuseand48hoursbeforepedestrianuse.extendthecuringtimeincool-weatherconditions.ToreducethetimeperiodinwhichMasterSealTraffic1500mightbevulnerabletoinclementweatherortoreducethetimebetweencoats,useMasterSeal914.
MaIntenanCe1.Portionsofthemembranethatexhibitwearareconsideredamaintenanceitem,andarenotconsideredawarrantableitem.
2.Surfacesmaybecleanedwithcommercialdetergents.BaSFrecommendsthatamaintenanceagreementbeestablishedbetweentheownerandapplicator.
3.Periodicinspectionandrepairofdamagedsurfaceswillgreatlyprolongtheperformanceandlifeofthesystem.
4.removeallsharpdebrissuchassand,gravelandmetalonaregularbasistoavoiddamagetothecoating.
5.Whenremovingsnow,avoidtheuseofmetalbladesorbucketsthatmaydamagethecoating.
4a. aggregaTeToreFuSaLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingattherateof30–50lbsper100ft2(1.0–1.25kg/m²).Immediatelyaftertheaggregatebroadcastandwhilethecoatingisstillwet,blowanyexcessaggregateviaaportableblowerforwardintothewetcoating.donotoverapplyaggregate;itisacceptabletohavelocalizedwetspotsintheaggregatesurfaceaftercompletionofthismethod.Thisprocessrequirescoordinationbetweenallofthemembersintheworkcrew.Thebloweroperator,wearingcleanspikedshoes,shouldblowtheexcessaggregateforwardtowardsthefreshlyappliedandbackrolledtopcoat.Inthismethod,thecoatingshouldnotacceptadditionalsand,minimalexcessaggregateisonthesurface,lessaggregateisusedandthetexturedappearanceshouldbefairlyuniform.
4B.BroadCaSTandBaCKroLLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingandbackrolltoencapsulatetheaggregate.evenlybroadcastaggregateattherateof10–15lbsper100ft2(0.5–0.75kg/m²).allowtocureovernight.
5.removealllooseaggregate,thenapply20mils(0.5mm)MasterSealTC225usingaflatsqueegeeat80ft2pergallon(2.0m2/L).ImmediatelybackrolltolevelMasterSealTC225.
6.Foradditionalslipresistance,immediatelybroadcastMasterSeal941orequivalent16–30roundedsilicasandatarateof7–10lbsper100ft2(.34–.49kg/m2)andbackrolltoencapsulate.
exTra-heavyduTySySTeM1.Primeconcretesubstrate(ifrequired).2.apply25wetmils(0.6mm)MasterSealM200usingapropernotchedsqueegeeat60ft2/gal(1.5m2/L).ImmediatelybackrolltolevelMasterSealM200.allowtocureovernight.
3.apply25wetmils(0.6mm)MasterSealTC225usingapropernotchedsqueegeeat50ft2/gal(1.2m2/L).ImmediatelybackrolltolevelMasterSealTC225.Thenextstep,#4,canutilizeeithermethoddescribedin4aor4B.
4a.aggregaTeToreFuSaLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingattherateof20–25lbsper100ft2(1.0–1.25kg/m²).Immediatelyaftertheaggregatebroadcastandwhilethecoatingisstillwet,blowanyexcessaggregateviaaportableblowerforwardintothewetcoating.donotoverapplyaggregate;itisacceptabletohavelocalizedwetspotsintheaggregatesurfaceaftercompletionofthismethod.Thisprocessrequirescoordinationbetweenallofthemembersintheworkcrew.Thebloweroperator,wearingcleanspikedshoes,shouldblowtheexcessaggregateforwardtowardsthefreshlyappliedandbackrolledtopcoat.Inthismethod,thecoatingshouldnotacceptadditionalsand,minimalexcessaggregateisonthesurface,lessaggregateisusedandthetexturedappearanceshouldbefairlyuniform
4B.BroadCaSTandBaCKroLLMeThodImmediatelybroadcastMasterSeal941orequivalent16–30mesh,roundedsilicasandintothewetcoatingandbackrolltoencapsulatetheaggregate.evenlybroadcastaggregateattherateof10–15lbsper100ft2(0.5–0.75kg/m²).allowtocureovernight.
MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us
HeaLtH, SafetY anD enVIROnMentaL read,understandandfollowallSafetydataSheetsandproductlabelinformationforthisproductpriortouse.TheSdScanbeobtainedbyvisitingwww.master-builders-solutions.basf.com,[email protected](800)433-9517.useonlyasdirected.for medical emergencies only, call Chemtrec® 1(800)424-9300.
CLean UPCleanalltoolsandequipmentwithMasterSeal990orxylene.
fOR BeSt PeRfORManCe•Concreteshouldhaveaminimumcompressivestrengthof3,000psi(20.7MPa)andbecuredforaminimumof28days.
•ForslabongradeapplicationspleasecontactBaSFrepresentative.
•Besuretoallowformovementinthedeckbytheproperdesignanduseofexpansionandcontroljoints.
•Whenapplyingsealants,usebackingmaterialsaccordingtoindustrystandards.
•donotapplywhensubstratesareover110°F(32°C)orunder40°F(4°C).
•Whenusedindoors,provideadequateventilationwithaminimumofsixairchangesperhour.
•WhenadequateventilationforuseofMasterSealTraffic1500cannotbemaintained,refertoproductdatasheetforMasterSealTraffic2500(Formno.1017917).
•Becertainthatallaggregatenotproperlyencapsulatedisthoroughlyremoved.
•onsteeprampsinexcessof15%,contactyourlocalBaSFrepresentative.
•MasterSeal94116⁄30,roundedselectsilicasandisrecommended.
•Whenapplyingtometalpandecksordeckscontainingbetween-slabmembranes,contactTechnicalService.
•Selecttheproperamountofaggregatetopromoteslipresistance.
•Pre-stripetoleveloutrecessedsealantjoints(lessthan1"[25mm])foroptimalaestheticappearance.
•avoidapplicationofMasterSealTraffic1500wheninclementweatherispresentorimminent.
•donotapplyMasterSealTraffic1500todamp,wet,orcontaminatedsurfaces.
•MasterSealTraffic1500isnotsuitableforusewherechainedormetal-studdedtireswillbeused.
•Properapplicationistheresponsibilityoftheuser.FieldvisitsbyBaSFpersonnelareforthepurposeofmakingtechnicalrecommendationsonlyandnotforsupervisingorprovidingqualitycontrolonthejobsite.
LIMIteD WaRRantY nOtICe BaSFwarrantsthisproducttobefreefrommanufacturingdefectsandtomeetthetechnicalpropertiesonthecurrentTechnicaldataguide,ifusedasdirectedwithinshelflife.Satisfactoryresultsdependnotonlyonqualityproductsbutalsouponmanyfactorsbeyondourcontrol.BaSFMaKeSnooTherWarranTyorguaranTee,exPreSSorIMPLIed,InCLudIngWarranTIeSoFMerChanTaBILITyorFITneSSForaParTICuLarPurPoSeWIThreSPeCTToITSProduCTS.ThesoleandexclusiveremedyofPurchaserforanyclaimconcerningthisproduct,includingbutnotlimitedto,claimsallegingbreachofwarranty,negligence,strictliabilityorotherwise,isthereplacementofproductorrefundofthepurchaseprice,atthesoleoptionofBaSF.anyclaimsconcerningthisproductmustbereceivedinwritingwithinone(1)yearfromthedateofshipmentandanyclaimsnotpresentedwithinthatperiodarewaivedbyPurchaser.BaSFWILLnoTBereSPonSIBLeForanySPeCIaL,InCIdenTaL,ConSequenTIaL(InCLudIngLoSTProFITS)orPunITIvedaMageSoFanyKInd.
Purchasermustdeterminethesuitabilityoftheproductsfortheintendeduseandassumesallrisksandliabilitiesinconnectiontherewith.ThisinformationandallfurthertechnicaladvicearebasedonBaSF’spresentknowledgeandexperience.however,BaSFassumesnoliabilityforprovidingsuchinformationandadviceincludingtheextenttowhichsuchinformationandadvicemayrelatetoexistingthirdpartyintellectualpropertyrights,especiallypatentrights,norshallanylegalrelationshipbecreatedbyorarisefromtheprovisionofsuchinformationandadvice.BaSFreservestherighttomakeanychangesaccordingtotechnologicalprogressorfurtherdevelopments.ThePurchaseroftheProduct(s)musttesttheproduct(s)forsuitabilityfortheintendedapplicationandpurposebeforeproceedingwithafullapplicationoftheproduct(s).Performanceoftheproductdescribedhereinshouldbeverifiedbytestingandcarriedoutbyqualifiedexperts.
TechnicaldataguideMasterSeal® traffic 1500
Crack Detail (Dynamic)
Crack Detail (Static)—Sporadic Cracking
Crack Detail (Static)—alternate Option for Widespread Cracking
expansion Joint Detail (Greater than 1”)
expansion Joint Detail (Less than 1”)
Plywood application (Seam Detail)
MasterBuildersSolutionsbyBaSFwww.master-builders-solutions.basf.us
key-Way or termination Detail
Penetration Detail
Slab abutting Wall
Joint at Wall/Slab
Roof Drain
Wall Bearing on Slab
©2014BaSFCorporationFormno.1017893rev07/14
BaSf Corporation 889valleyParkdrive,Shakopee,Mn55379 Customer Service 1(800)433.9517Construction Systems www.master-builders-solutions.basf.us technical Service 1(800)243.6739
TechnicaldataguideMasterSeal® traffic 1500