7 2015 GBR en 0615 - dentex.ro
Transcript of 7 2015 GBR en 0615 - dentex.ro
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
019018
SmartBuilder
SmartBuilder - Titanium
SB1 Papilla Builder
SB1Papilla Builder
SB2Lateral Builder
SB3Jaw Builder
P = Proximal BL = Buccal Length BD = Buccal Distance LD = Lingual Distance
�3D pre-formed design, no trimming & bending necessary
- For bone defect reconstruction
- Various sizes and configurations available�Ti-mesh with no risk of soft tissue exposure
- No sharp edges or wrinkles due to the 3D pre-formed design
- Directly anchored to the implant or to the jaw, bone graft material stays securely in place �Excellent bone regeneration
- Allows ample blood flow through pores�Choose either non-submerged or submerged closure
- Healing Cap for non-submerged closure
- Cover Cap for submerged closure�Simultaneous GBR + fixture placement: healing cap or cover cap + SmartBuilder + SB anchor + fixture�If remaining the bone is narrow or insufficient: healing cap or cover cap + SmartBuilder + tenting screw※ Disposable; Do not re-use
Titanium membrane for aestheticreconstruction of the papilla when alveolar
bone recession is less than 1.5 mm.One-stage procedure is possible for GBR andimmediate placement after tooth extraction.
Titanium membrane for reconstructingminor vertical and horizontal bonedefects due to a socket extraction,
fenestration and dehiscence defects.
Titanium membrane forreconstructing alveolar ridges withsevere vertical and horizontal bone
recession of 5-10 mm.
P
BL LD BD
7mm Scallop shape
P
BLLD BD
10mm Scallop shape
P
BLLD BD
12mm Scallop shape
P P BL BD LD
10 3 5.5 5.5 SB1P103A
10 5 5.5 5.5 SB1P105A
12 3 6.5 6.5 SB1P123A
12 5 6.5 6.5 SB1P125A
7 3 5 5 SB1P73A
7 5 5 5 SB1P75A
SMART 3D Design
SMART Handling
SMART Covering
SMART Conduction
SMART Healing
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
020 021
SmartBuilder - Titanium
SB2 Lateral Builder
10 7 3.5 5.5 3.7 SB3H107F10 9 4.5 5.5 3.7 SB3H109F 10 11 6 5.5 3.7 SB3H1011F
Horizontal
20 7 3.5 5.5 3.7 SB3H207F 20 9 4.5 5.5 3.7 SB3H209F20 11 6 5.5 3.7 SB3H2011F
Horizontal
10 7 7 5.5 5.5 SB3V107F10 9 9 5.5 5.5 SB3V109F 10 11 11 5.5 5.5 SB3V1011F
Vertical
20 7 7 5.5 5.5 SB3V207F20 9 9 5.5 5.5 SB3V209F 20 11 11 5.5 5.5 SB3V2011F
Vertical
SB3 Jaw Builder
P = Proximal BW = Buccal WidthBL = Buccal LengthBD = Buccal Distance
BW = Buccal WidthBL = Buccal LengthLL = Lingual LengthBD = Buccal DistanceLD = Lingual Distance
BW
BLBD
2 WallBuccal-Proximal
2 WallBuccal-Lingual
3 Wall
P
4 8 7 5.5 SM1W487SB4 10 7 5.5 SM1W4107SB4 10 9 5.5 SM1W4109SB
7 9 7 5.5 SM2W797SB7 9 9 5.5 SM2W799SB10 12 7 5.5 SM2W10127SB10 12 9 5.5 SM2W10129SB12 12 7 5.5 SM2W12127SB12 12 9 5.5 SM2W12129SB
5 9 7 5.5 SM2W597SE5 9 9 5.5 SM2W599SE6 12 7 5.5 SM2W6127SE6 12 9 5.5 SM2W6129SE7 12 7 5.5 SM2W7127SE7 12 9 5.5 SM2W7129SE
7 9 7 5.5 SM3W797SB7 9 9 5.5 SM3W799SB10 12 7 5.5 SM3W10127SB10 12 9 5.5 SM3W10129SB12 12 7 5.5 SM3W12127SB12 12 9 5.5 SM3W12129SB
BW
P
BLBD
BW
P
BLBD
BL
BW
LL
BDLD
BL
BW
LL
BDLD
BW
BL
BW
LLBDLD
BLLLBDLD
BW
P
BLBD
1 Wall
P BW BL BD Augmentation BW BL LL BD LDAugmentation
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
022 023
SBHC4030
SBHC5030
SBHC5030D
SBHC4040
SBHC5040
SBHC5040D
Ø4.0Ø5.0Ø5.0
D
SmartBuilder Components
D
H
0.3
∅4.0
Healing Cap for TS
�Non-submerged closure�Compatible with SB1, SB2 and SB3 (unavailable for ∅5.0, SB1)�Use a 0.9 hex hand driver�Recommended tightening torque : 5-8 N cm※ Disposable; Do not re-use
3.0 4.0D H
SBCC4000Ø4.0
Ø3.5Ø4.0
Cover Cap for TS
�Submerged closure�Compatible with SB1, SB2 and SB3�Use a 0.9 hex hand driver�Recommended tightening torque: 5-8 N cm※ Disposable; Do not re-use
0.3D H
SB Anchor for TS
�For use with TS fixture only�Compatible with SB1, SB2 and SB3�Use a 0.9 hex hand driver�Recommended tightening torque: 12-15 N cm※ Disposable; Do not re-use
D H 0
SBAC3500TSM
SBAC4000TSR
0.5
SBAC3505TSM
SBAC4005TSR
1.0
SBAC3510TSM
SBAC4010TSR
1.5
SBAC3515TSM
SBAC4015TSR
2.5
SBAC3525TSM
SBAC4025TSR
2.0
SBAC3520TSM
SBAC4020TSR
3.0
SBAC3530TSM
SBAC4030TSR
For SB1 only
SMHA443R
SMHA553R
SMHA444R
SMHA554R
Ø4.0Ø5.0
D
H
1.5
∅4.0
Healing Cap for US
�Non-submerged closure�Compatible with SB1, SB2 and SB3�Use a 1.2 hex hand driver�Recommended tightening torque: 5-8 N cm※ Disposable; Do not re-use
3.0 4.0D H
SMCC415Ø4.0
Cover Cap for US
�Submerged closure�Compatible with SB1, SB2 and SB3�Use a 0.9 hex hand driver or a cover cap driver�Recommended tightening torque: 5-8 N cm※ Disposable; Do not re-use
1.5D H
H
Ø3.5Ø4.0Ø5.1Ø5.0
SB Anchor for US
�For use with US fixture only�Compatible with SB1, SB2 and SB3�Use a 1.2 hex hand driver�Recommended tightening torque: 12-15 N cm※ Disposable; Do not re-use
D H 1.0
SMHI310USM
SMHI410USR
SMHI510USW
SMHI510USP
1.5
SMHI315USM
SMHI415USR
SMHI515USW
SMHI515USP
2.0
SMHI320USM
SMHI420USR
SMHI520USW
SMHI520USP
2.5
SMHI325USM
SMHI425USR
SMHI525USW
SMHI525USP
3.0
SMHI330USM
SMHI430USR
SMHI530USW
SMHI530USP
D
H
For SB1 only
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
025024
SMDG
Tenting Screw
�Easy suturing, the height of the "tent" is lower than the external type�Used in place of a fixture when there is insufficient osteoid volume or bone width�Compatible with SB1, SB2 and SB3�Recommended insertion depth: >3~5 mm for hard/normal bone and >5 mm for soft bone�Use a 0.9 hex torque driver, torque slowly�Compatible with cover cap (TS) and healing cap (TS)※ Disposable; Do not re-use
L 8.5
SBS2008I
10
SBS2010I
11.5
SBS2011I
13
SBS2013I
L
Defect Gauge
�Measures a defect's height (vertical) and width (horizontal)�4-5, 9-10 and 14-15 thick lines�Markers in 1 mm increments※Carefully measure the defect to select the appropriate SmartBuilder to
avoid additional modifications like trimming and bending.
SmartBuilder Components
AutoBoneCollector
TentingScrew Drill
Tenting Screw
Bone Ejector
SmartBuilderComponents
MachineScrew Driver
Hand Driver
AHD09LHSHD12LH
ABBE52LAMSD09LAMSD12L
TD1013TLTD1513TL
SNST3SNST5SNST7
ABC504LABC604L
Defect Gauge
SMDG
�Incorporates all the tools necessary for applying SmartBuilders�Connects SmartBuilders: SB1, SB2, SB3 and SB anchor, cover cap, and healing cap�Tenting screw prevents a wide range of vertical and horizontal bone loss even in bone with a narrow width�Harvest autogenous bone using the AutoBone collector
Components
SmartBuilder KIT (HGBRK)
ItemTenting Screw Drill Ø1.0, Ø1.5 Default
Stopper 3, 5, 7mm Default
Machine Screw Driver 0.9 hex long, 1.2 hex long Default
Hex Hand Driver 0.9 hex long, 1.2 hex long Default
Ø3.0, Ø4.0 Option
Ø5.0, Ø6.0 Default
TS mini, regular(0~1.5mm) Default
TS mini, regular(2.0~3.0mm) Option
Healing Cap Ø4.0, Ø5.0(3, 4mm) Default
Tenting Screw 8.5, 10, 11.5, 13mm Default
Cover Cap - Default
Bone Ejector - Default
Defect Gauge - Default
Specification Default/Option
Middleplate
Bottomplate
AutoBone Collector
SB Anchor
�Use a 1.2 hex torque driver, torque slowly�Compatible with cover cap (TS) and healing cap (US)※ Disposable; Do not re-use
L 8.5
SBS2008E
10
SBS2010E
11.5
SBS2011E
13
SBS2013E
L
∅3.0
∅2.1
∅3.0
∅2.1
External Type
Internal Type
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
026 0273 5 7
Stopper
�Use with tenting screw drill to limit drilling depth
13
DTD1013TL TD1513TL13
Tenting Screw Drill
�Initial drilling recommended before inserting the tenting screw�Hard bone : ∅1.5 / normal, soft bone : ∅1.0 drill �Laser markers : 1, 2, 3, 4, 5, 6, 7 and 8 mm �Recommended rpm : 1200-1,500 rpm�Use with Stopper System : 3-7 mm
Ø1.0
Ø1.0 Ø1.5
Ø1.5L D
SNST3
3mm
SNST5
5mm
SNST7
7mmLength ofprotrusion
SmartBuilder KIT Surgical Instruments AutoBone Collector
D
H
Drill
�Drill and Stopper Set, comes in ∅3.0 to ∅6.0 sizes
�Recommended rpm: 300-600 rpm
�Use of drill and stopper: 50 times
※ Harvest autogenous bone by drilling 4 mm into the donor location until the
Stopper clicks into the Phase II Locking position. (stop drilling and collect
harvested autogenous bone in the Stopper)
Ø6.0ABC604S
ABC604L
Ø5.0ABC504S
ABC504L
Ø4.0ABC404S
ABC404L
Ø3.0ABC304S
ABC304L
L
ShortLong
D
Stopper
AutoBone Collector
�Limits drilling depth up to 4 mm to harvest cortical bone
�Collects harvested autogenous bone during drilling
Bone Ejector
�Removes harvested autogenous bone from inside the Stopper
Ø6.0ABC2ST604S
ABC2ST604L
Ø5.0ABC2ST504S
ABC2ST504L
Ø4.0ABC2ST404S
ABC2ST404L
Ø3.0ABC2ST304S
ABC2ST304L
L
ShortLong
D
ABBE52L
Ø3.0/Ø4.0/Ø5.0/Ø6.0D
Guideline for connecting the2-stage locking Stopper
Slide the Stopper onto thedrill until it clicks into thePhase I Locking position
Stop drilling when theStopper clicks into the
Phase II Locking position
※ Please refer to the instructional video for detailed use
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
029028
Bone Screw
L 4
BSCH1404
6
BSCH1406
L
D Ø1.4
L 8 1210D Ø2.0
8
BSCH1408 --
BSCH2008 BSCH2012BSCH2010
14
BSCH2014
16
BSCH2016
D
Ø1.4
�Affix membrane, mesh, bone plate, etc.
�Sharp apex, self-drilling
Ø2.0
�Affix block bone, etc.
�Insert after initial drilling (no self-drilling function)
�Machine surface
�Material: Ti-6Al-4V※ Disposable; Do not re-use
GB
R &
Dental M
aterial
GB
R &
Dental M
aterial
035034
BeauTis Whitening System
�BeauTis 3: Low concentrate whitener with 3% hydrogen
peroxide (no sensitivity)
�BeauTis 15: High concentrate whitener with 15%
hydrogen peroxide (excellent whitening power)
�BTS procedure KIT: BTS DAM, lip wider, lip cover and bag
�BeauTis light: High intensity, blue LED irradiator
BeauTis
BeauTis 3
BeauTis 15
BTS Procedure KIT
BeauTis Light
WGL003
WGL015
BWK001
BWL001
5g
5g
-
-
AIC Consulting Model for Patients
�Maxillary sinus graft & GBR (incorporates 5 fixtures)
�Comparison of submaxillary bridge vs. implant (incorporates 1 fixture)
AICCM001
L
ShortLong
D
1st AIC Consulting Model
�Submaxillary implant overdenture model
�Submaxillary implant overdenture (incorporates 4 fixtures)
AICCM002
L
ShortLong
D
2nd AIC Consulting Model
�Model of implants per maxillary case
�Posterior maxillary area - right side: ridge split (incorporates 3 fixtures)
- left side: GBR (incorporates 2 fixtures)
�Comparison of anterior submaxillary bridge vs. implant (incorporates 1 fixture)
AICCM003
L
ShortLong
D
3rd AIC Consulting Model
GB
R &
Dental M
aterial
036
AICCM004
L
ShortLong
D
�South Korea's first skull model with a comprehensive examples of dental implant cases
�Posterior maxillary area - right side : maxillary floor sinus augmentation
- left side : bridge & implant-screwed prosthesis
�Posterior submaxillary area - right side : comparison of dentulous & implant procedures
- left side : GBR using SmartBuilder
�Mini implants (MS) in narrow ridge of the anterior submaxillary (incorporates 11 fixtures)
�Neural right side of the submaxillary area (to explain anatomical structures)
4th AIC Consulting Model
AIC Consulting Model for Patients