7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT...

5
A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) D ( 1 : 5 ) LEFT MOUNTED E ( 1 : 5 ) RIGHT MOUNTED 8920082 / RSK75110.5BL PE SafeEnd SIDE CAP 2 11 1123160000 M6M M16 HDG HEX NUT M16 6 10 1126173400 17x34 HDG WASHER ROUND 12 9 1120161500 M16x150 HDG BOLT M16 6 8 8920026 HDG CONNECTION REVERSIBLE 1 7 1126132402 13x24x4 HDG WASHER ROUND TBRUB 1 6.3 1120120300 M12x30 HDG SCREW M12 1 6.2 8920505 HDG CONNECTOR PLATE 1 6.1 8920301A (ASSAMBLED) HDG C-POST 140x40 1 6 112320000 M6M M20 HDG HEX NUT M20 2 5 1126213600 21x36 HDG WASHER ROUND 10 4 1120120080 M20x80 HDG CARRIAGE BOLT M20 2 3 8920531 / 8920530 2000 / 1500 HDG Birsta "Nail" ANCHOR TUBE 1 2 89200080 Birsta SafeEnd 1 1 A B C D E Copyright Birstaverken AB S a f e E n d 0 7 Rev. Drawing no. Date Scale Copied Design. Drawn Stand. Checked Appr. Replaces Replaced by www.birsta.eu a SAFEROAD company GLN GLN FSö GLN 1:20 2015-02-23 SafeEnd 07 Birsta SafeEnd P4 PROFILE-A LEFT/RIGHT 507,9 kg ASSEMBLY DRAWING In Review 652 20 8450 SafeEnd ~ CONNECTION ~700 6800 20 250 1 2 33 3 4 5 OPTION: 8920081 PLASTIC COVER MOUNTED ON SITE WITH 6x MAURUTEX SCREW A2 M5,5x20. CAN BE PROVIDED WITH VARIOUS TYPE OF REFLEX, POINTING TO RIGHT, LEFT OR MIDDLE EX. 6 8 9 10 CONNECTING SYSTEM SINGLE SIDED PROFILE-A (W-PROFILE) HEIGHT 700 / 750 MM HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING ACCORDING TO EN ISO 1461 BOLT, SCREWS & NUTS ACC. TO EN ISO 10648 6.1 6.2 6.3 HEIGHT ACC. TO CONNECTING SYSTEM 8700 50 1900 20 REGULATIONS ENV 1317-4 EN ISO 1461 (HOT DIP GAVANIZING) ADDITIONAL INFORMATION PERFOMANCE LEVEL: P4 IMPACT SEVERITY LEVEL: B LATERAL DISPLACEMENT CLASS: D1.1 REDIRECTION ZONE: Z1 7 ~ 295 33 11

Transcript of 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT...

Page 1: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT MOUNTED D ( 1 : 5 ) LEFT MOUNTED 11 2 SafeEnd SIDE CAP PE 8920082 / RSK75110.5BL10

A ( 1 : 5 )

B ( 1 : 5 )

C ( 1 : 5 )

D ( 1 : 5 ) LEFT MOUNTEDE ( 1 : 5 ) RIGHT MOUNTED

8920082 / RSK75110.5BL PESafeEnd SIDE CAP211

1123160000M6M M16HDGHEX NUT M16610

112617340017x34HDGWASHER ROUND129

1120161500M16x150HDGBOLT M16 68

8920026 HDGCONNECTION REVERSIBLE17

112613240213x24x4HDGWASHER ROUND TBRUB16.3

1120120300M12x30HDGSCREW M12 16.2

8920505 HDG CONNECTOR PLATE16.1

8920301A (ASSAMBLED) HDGC-POST 140x40 16

112320000M6M M20HDGHEX NUT M2025

112621360021x36HDGWASHER ROUND104

1120120080M20x80HDGCARRIAGE BOLT M2023

8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12

89200080 Birsta SafeEnd11

A

BC

D

E

Cop

yright

Birst

aver

ken

AB

SafeEnd 07Rev.Drawing no.

Date

ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by

www.birsta.eu a SAFEROAD company

GLNGLN FSö GLN 1:20

2015-02-23

SafeEnd 07

Birsta SafeEnd P4PROFILE-A LEFT/RIGHT

507,9 kg

ASSEMBLY DRAWING In Review

652`20

8450SafeEnd ~ CONNECTION ~700

6800`20

250

1

2

33

345

OPTION: 8920081

PLASTIC COVER MOUNTED ON SITE WITH 6x

MAURUTEX SCREW A2 M5,5x20.

CAN BE PROVIDED WITH VARIOUS TYPE OF

REFLEX, POINTING TO RIGHT, LEFT OR

MIDDLE EX.

6

8 9 10

CONNECTING SYSTEM

SINGLE SIDED PROFILE-A (W-PROFILE)

HEIGHT 700 / 750 MM

HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING

ACCORDING TO EN ISO 1461

BOLT, SCREWS & NUTS ACC. TO EN ISO 10648

6.16.26.3

HEIGHT ACC. TO CONNECTING SYSTEM

8700`50

1900`20

REGULATIONS

ENV 1317-4

EN ISO 1461 (HOT DIP GAVANIZING)

ADDITIONAL INFORMATION

PERFOMANCE LEVEL: P4

IMPACT SEVERITY LEVEL: B

LATERAL DISPLACEMENT CLASS: D1.1

REDIRECTION ZONE: Z1

7

~ 295

33

11

Page 2: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT MOUNTED D ( 1 : 5 ) LEFT MOUNTED 11 2 SafeEnd SIDE CAP PE 8920082 / RSK75110.5BL10

A ( 1 : 5 )

B ( 1 : 5 )

C ( 1 : 5 )

D ( 1 : 5 )

8920082 / RSK75110.5BL PESafeEnd SIDE CAP211

1123160000M6M M16HDGHEX NUT M16610

112617340017x34HDGWASHER ROUND129

1120161500M16x150HDGBOLT M16 68

8920029 HDGCONNECTION DOUBLE17

112613240213x24x4HDGWASHER ROUND TBRUB16.3

1120120300M12x30HDGSCREW M12 16.2

8920505 HDG CONNECTOR PLATE16.1

8920301A (ASSAMBLED) HDGC-POST 140x40 16

112320000M6M M20HDGHEX NUT M2025

112621360021x36HDGWASHER ROUND104

1120120080M20x80HDGCARRIAGE BOLT M2023

8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12

89200080 Birsta SafeEnd11

A

BC

D

Cop

yright

Birst

aver

ken

AB

SafeEnd 08Rev.Drawing no.

Date

ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by

www.birsta.eu a SAFEROAD company

GLNGLN LGN LGN 1:20

2015-02-25

SafeEnd 08

Birsta SafeEnd P4PROFILE-A DOUBLE

517,4 kg

ASSEMBLY DRAWING In Review

652`20

8450SafeEnd ~ CONNECTION ~700

6800`20

250

1

2

345

OPTION: 8920081

PLASTIC COVER MOUNTED ON SITE WITH 6x

MAURUTEX SCREW A2 M5,5x20.

CAN BE PROVIDED WITH VARIOUS TYPE OF

REFLEX, POINTING TO RIGHT, LEFT OR

MIDDLE EX.

6

8 9 10

CONNECTING SYSTEM

DOUBLE PROFILE-A (W-PROFILE)

HEIGHT 700 / 750 MM

HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING

ACCORDING TO EN ISO 1461

BOLT, SCREWS & NUTS ACC. TO EN ISO 10648

6.16.26.3

HEIGHT ACC. TO CONNECTING SYSTEM

8700`50

1900`20

REGULATIONS

ENV 1317-4

EN ISO 1461 (HOT DIP GAVANIZING)

ADDITIONAL INFORMATION

PERFOMANCE LEVEL: P4

IMPACT SEVERITY LEVEL: B

LATERAL DISPLACEMENT CLASS: D1.1

REDIRECTION ZONE: Z1

7

~ 29511

L=20

00 IN G

RAVEL

L=1500

IN A

SPHALT

Page 3: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT MOUNTED D ( 1 : 5 ) LEFT MOUNTED 11 2 SafeEnd SIDE CAP PE 8920082 / RSK75110.5BL10

A ( 1 : 5 )

B ( 1 : 5 )

C ( 1 : 5 )

D ( 1 : 5 ) LEFT MOUNTEDE ( 1 : 5 ) RIGHT MOUNTED

8920082 / RSK75110.5BL PESafeEnd SIDE CAP211

1123160000M6M M16HDGHEX NUT M16610

112617340017x34HDGWASHER ROUND129

1120161500M16x150HDGBOLT M16 68

8920031 HDGCONNECTION REVERSIBLE17

112613240213x24x4HDGWASHER ROUND TBRUB16.3

1120120300M12x30HDGSCREW M12 16.2

8920505 HDG CONNECTOR PLATE16.1

8920301A (ASSAMBLED) HDGC-POST 140x40 16

112320000M6M M20HDGHEX NUT M2025

112621360021x36HDGWASHER ROUND104

1120120080M20x80HDGCARRIAGE BOLT M2023

8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12

89200080 Birsta SafeEnd11

A

BC

D

E

Cop

yright

Birst

aver

ken

AB

SafeEnd 09Rev.Drawing no.

Date

ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by

www.birsta.eu a SAFEROAD company

GLNGLN FSö GLN

2015-02-26

SafeEnd 09

Birsta SafeEnd P4PROFILE-B LEFT/RIGHT

508,1 kg

ASSEMBLY DRAWING In Review

652`20

8450SafeEnd ~ CONNECTION ~700

6800`20

250

1

2

28

345

OPTION: 8920081

PLASTIC COVER MOUNTED ON SITE WITH 6x

MAURUTEX SCREW A2 M5,5x20.

CAN BE PROVIDED WITH VARIOUS TYPE OF

REFLEX, POINTING TO RIGHT, LEFT OR

MIDDLE EX.

6

8 9 10

CONNECTING SYSTEM

SINGLE SIDED PROFILE-B

HEIGHT 700 / 750 MM

HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING

ACCORDING TO EN ISO 1461

BOLT, SCREWS & NUTS ACC. TO EN ISO 10648

6.16.26.3

HEIGHT ACC. TO CONNECTING SYSTEM

8700`50

1900`20

REGULATIONS

ENV 1317-4

EN ISO 1461 (HOT DIP GAVANIZING)

ADDITIONAL INFORMATION

PERFOMANCE LEVEL: P4

IMPACT SEVERITY LEVEL: B

LATERAL DISPLACEMENT CLASS: D1.1

REDIRECTION ZONE: Z1

7

~ 29511

L=20

00 IN G

RAVEL

L=1500

IN A

SPHALT

30

Page 4: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT MOUNTED D ( 1 : 5 ) LEFT MOUNTED 11 2 SafeEnd SIDE CAP PE 8920082 / RSK75110.5BL10

A ( 1 : 5 )

B ( 1 : 5 )

C ( 1 : 5 )

D ( 1 : 5 )

8920082 / RSK75110.5BL PESafeEnd SIDE CAP211

1123160000M6M M16HDGHEX NUT M16610

112617340017x34HDGWASHER ROUND129

1120161500M16x150HDGBOLT M16 68

8920032 HDGCONNECTION 17

112613240213x24x4HDGWASHER ROUND TBRUB16.3

1120120300M12x30HDGSCREW M12 16.2

8920505 HDG CONNECTOR PLATE16.1

8920301A (ASSAMBLED) HDGC-POST 140x40 16

112320000M6M M20HDGHEX NUT M2025

112621360021x36HDGWASHER ROUND104

1120120080M20x80HDGCARRIAGE BOLT M2023

8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12

89200080 Birsta SafeEnd11

A

BC

D

Cop

yright

Birst

aver

ken

AB

SafeEnd 10Rev.Drawing no.

Date

ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by

www.birsta.eu a SAFEROAD company

GLNGLN FSö GLN

2015-03-05

SafeEnd 10

Birsta SafeEnd P4PROFILE-B DUBLE

N/A

ASSEMBLY DRAWING In Review

652`20

8450SafeEnd ~ CONNECTION ~700

6800`20

250

1

2

345

OPTION: 8920081

PLASTIC COVER MOUNTED ON SITE WITH 6x

MAURUTEX SCREW A2 M5,5x20.

CAN BE PROVIDED WITH VARIOUS TYPE OF

REFLEX, POINTING TO RIGHT, LEFT OR

MIDDLE EX.

6

8 9 10

CONNECTING SYSTEM

DOUBLE SIDED PROFILE-B

HEIGHT 700 / 750 MM

HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING

ACCORDING TO EN ISO 1461

BOLT, SCREWS & NUTS ACC. TO EN ISO 10648

6.16.26.3

HEIGHT ACC. TO CONNECTING SYSTEM

8700`50

1900`20

REGULATIONS

ENV 1317-4

EN ISO 1461 (HOT DIP GAVANIZING)

ADDITIONAL INFORMATION

PERFOMANCE LEVEL: P4

IMPACT SEVERITY LEVEL: B

LATERAL DISPLACEMENT CLASS: D1.1

REDIRECTION ZONE: Z1

7

~ 29511

L=20

00 IN G

RAVEL

L=1500

IN A

SPHALT

Page 5: 7 0 E S CONNECTION ~700 SafeEnd ~ 8450 ......A ( 1 : 5 ) B ( 1 : 5 ) C ( 1 : 5 ) E ( 1 : 5 ) RIGHT MOUNTED D ( 1 : 5 ) LEFT MOUNTED 11 2 SafeEnd SIDE CAP PE 8920082 / RSK75110.5BL10

A ( 1 : 5 )

B ( 1 : 5 )

C ( 1 : 5 )

8920082 / RSK75110.5BL PESafeEnd SIDE CAP211

1123160000M6M M16HDGHEX NUT M16610

112617340017x34HDGWASHER ROUND129

1120161500M16x150HDGBOLT M16 68

HDGCONNECTION17

112613240213x24x4HDGWASHER ROUND TBRUB16.3

1120120300M12x30HDGSCREW M12 16.2

8920505 HDG CONNECTOR PLATE16.1

8920301A (ASSAMBLED) HDGC-POST 140x40 16

112320000M6M M20HDGHEX NUT M2025

112621360021x36HDGWASHER ROUND104

1120120080M20x80HDGCARRIAGE BOLT M2023

8920531 / 89205302000 / 1500HDGBirsta "Nail" ANCHOR TUBE12

89200080 Birsta SafeEnd11

A

B

C

Cop

yright

Birst

aver

ken

AB

SafeEnd 11Rev.Drawing no.

Date

ScaleCopiedDesign. Drawn Stand.Checked Appr. Replaces Replaced by

www.birsta.eu a SAFEROAD company

GLNGLN LGN LGN 1:20

2015-02-26

SafeEnd 11

Birsta SafeEnd P4ER OBB

525,1 kg

ASSEMBLY DRAWING In Review

652`20

8450SafeEnd ~1544CONNECTION ~

6800`20

250

1

2

345

OPTION: 8920081

PLASTIC COVER MOUNTED ON SITE WITH 6x

MAURUTEX SCREW A2 M5,5x20.

CAN BE PROVIDED WITH VARIOUS TYPE OF

REFLEX, POINTING TO RIGHT, LEFT OR

MIDDLE EX.

6

8 9 10

CONNECTING SYSTEM

ER OBB

HEIGHT 720±30 MM

HDG. IN PART LIST STANDS FOR HOT DIP GALVANIZING

ACCORDING TO EN ISO 1461

BOLT, SCREWS & NUTS ACC. TO EN ISO 10648

6.16.26.3

HEIGHT ACC. TO CONNECTING SYSTEM±

8700`50

1900`20

REGULATIONS

ENV 1317-4

EN ISO 1461 (HOT DIP GAVANIZING)

ADDITIONAL INFORMATION

PERFOMANCE LEVEL: P4

IMPACT SEVERITY LEVEL: B

LATERAL DISPLACEMENT CLASS: D1.1

REDIRECTION ZONE: Z1

~ 29511

L=20

00 IN G

RAVEL

L=1500

IN A

SPHALT

998

7