652 Section 05 Review
description
Transcript of 652 Section 05 Review
![Page 1: 652 Section 05 Review](https://reader035.fdocuments.in/reader035/viewer/2022072007/55cf8edc550346703b966870/html5/thumbnails/1.jpg)
API 652
REVIEW Section 51. Corrosion prevention, tank design, tank history, environmental considerations,
flexibility of service change, upset conditions, and jurisdictional requirements are all considerations used to:
Establish the need for an internal tank bottom lining. 5.12. Considering the corrosion history of tanks in similar service is one way to establish a
__________ for a new tank. Corrosion rate, 5.4
3. The tank pad material beneath the steel bottom of a tank has a significant effect on the underside:
Corrosion. 5.4.14. What should be considered on tank bottoms for cone-roof column supports and
floating roof support columns? Add support or landing plates beneath the columns. 5.4.2
5. If a tank has an old lining and a new lining is used, the new lining must be: Compatible with the old lining or the old lining must be completely removed.
5.4.2.16. A properly applied tank bottom lining may provide _______ years of service life.
10-20. 5.6
1