SYOPTICS TEST CENTER Shenzhen Huadian Lighting Co., Ltd. LED Panel Light Light Output Ratio: 100.0% Luminaire Power: 60 W SHR Nominal: 1.25 Calculated using the TM5 SHR Maximum: 1.35 fine grid method. C Range: 0 - 360DEG C Interval: 10.0DEG Range: 0 - 90DEG Interval: 1.0DEG Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254 Temperature:25.2DEG Humidity:65.1% Test Distance:8.040m [K=1.0000] Operators:Yuan Feng Test Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes Checker: Yuan Feng Assessor: Jianwei Liu

Transcript of 60120-60w

SYOPTICS TEST CENTER

Shenzhen Huadian Lighting Co., Ltd.

LED Panel Light

Light Output Ratio: 100.0%

Luminaire Power: 60 W

SHR Nominal: 1.25 Calculated using the TM5

SHR Maximum: 1.35 fine grid method.

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180,115.3°

AVERAGE BEAM ANGLE(50%):115.3 DEG

0

400

800

1200

1600

2000

-180.0 -144.0 -108.0 -72.0 -36.0 0.0 36.0 72.0 108.0 144.0 180.0ANGLE(DEG)

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

0

400

800

1200

1600

2000

INTENSITY(cd)

C0/180

AVERAGE BEAM ANGLE(50%):115.3 DEG

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC90/270,115.2°

AVERAGE BEAM ANGLE(50%):115.2 DEG

0

400

800

1200

1600

2000

-180.0 -144.0 -108.0 -72.0 -36.0 0.0 36.0 72.0 108.0 144.0 180.0ANGLE(DEG)

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM

0

400

800

1200

1600

2000

INTENSITY(cd)

C90/270

AVERAGE BEAM ANGLE(50%):115.2 DEG

Fig. C0/C180 Fig. C90/C270

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

LUMINAIRE PHOTOMETRIC TEST REPORT

NAME: LED Panel Light

DIM.: 1200X596X9mm

MFR.: Shenzhen Huadian Lighting Co., Ltd.

SPEC.:600X1200UL frame

SUR.:1146X546mm

SERIAL No.:2014110503

Test:U:220.1V I:0.2820A P:60.00W PF:0.9650 Lamp Flux:4901.12x1 lm

0

30

60

90

120

150

-/+180

-150

-120

-90

-60

-30

UNIT:cdC0/180,115.3°

UNIT:cd

C90/270,115.2°

AVERAGE BEAM ANGLE(50%):115.3 DEG

0

400

800

1200

1600

2000

LUMINOUS INTENSITY DISTRIBUTION DIAGRAM PLANAR ISOLUX DIAGRAM(UNIT:lx)

MH=1m

S(m)0

1

2

3

90

80

70

60

50

40

30

20100

C(DEG)

13001100970810650

49016081.049.016.0

DATA OF LAMP PHOTOMETRIC DATA Eff: 81.69 lm/W

MODEL

NOMINAL POWER(W)

RATED VOLTAGE(V)

NOMINAL FLUX(lm)

LAMPS INSIDE

TEST VOLTAGE(V)

Imax(cd)

LOR(%)

TOTAL FLUX(lm)

CIE CLASS

up(%)

down(%)

S/MH(C0/180)

S/MH(C90/270)

UP,DN(C0-180)

UP,DN(C180-360)

CIBSE SHR NOM

CIBSE SHR MAX

LED

60

220

4901.12

1

220.1

1625

100.0

4901.1

DIRECT

0.0

100.0

1.28

1.28

0.0,50.0

0.0,50.0

1.25

1.35

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES

ZONAL FLUX DIAGRAM:

10 0- 10

20 10- 20

30 20- 30

40 30- 40

50 40- 50

60 50- 60

70 60- 70

80 70- 80

90 80- 90

100 90-100

110 100-110

120 110-120

130 120-130

140 130-140

150 140-150

160 150-160

170 160-170

180 170-180

C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp

DEG LUMINOUS INTENSITY:cd UNIT:lm

1600 1599 1598 1597 1598 1597 1598 1599 153.7 153.7 3.14,3.14

1522 1521 1522 1523 1519 1523 1522 1521 442.2 595.9 12.2,12.2

1396 1394 1395 1398 1391 1398 1395 1394 675.2 1271 25.9,25.9

1222 1222 1222 1227 1218 1227 1222 1222 822.6 2094 42.7,42.7

1010 998.2 988.4 1004 982.6 1004 988.4 998.2 860.8 2954 60.3,60.3

765.0 756.6 750.9 763.9 741.5 763.9 750.9 756.6 788.9 3743 76.4,76.4

501.7 498.1 498.1 505.7 483.0 505.7 498.1 498.1 624.6 4368 89.1,89.1

239.6 242.8 249.0 249.2 227.1 249.2 249.0 242.8 390.5 4759 97.1,97.1

29.81 30.00 29.58 31.52 11.46 31.52 29.58 30.00 142.6 4901 100,100

LUMINANCE LIMITATION CURVES

GLARE CLASS ILLUMINANCE (lx)

1.15 A 2000 1000 500 <=300

1.50 B 2000 1000 500 <=300

1.85 C 2000 1000 500 <=300

2.20 D 2000 1000 500 <=300

2.55 E 2000 1000 500 <=300

a b c d e f g h

45

55

65

75

85G(DEG)

8 1000 2 3 4 5 6 8 10000 2 3 4 1

2

3

4

68

a/h

LUMINANCE (cd/(m2))

a b c d e f g h

C0/180 C90/270

LUMINANCE cd/(m2)

G(DEG) C0/180 C90/270

85 2285 2434

80 2205 2292

75 2240 2295

70 2344 2328

65 2397 2369

60 2445 2400

55 2483 2431

50 2511 2458

45 2533 2505

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM

cc

w

fc

RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

1.19

1.03

.89

.78

.69

.62

.55

.50

.46

.42

.39

1.19

.98

.82

.70

.60

.52

.46

.41

.37

.34

.31

1.19

.94

.76

.63

.53

.46

.40

.35

.31

.28

.25

1.16

1.01

.87

.77

.68

.60

.54

.49

.45

.41

.38

1.16

.97

.81

.69

.59

.52

.46

.41

.37

.33

.30

1.16

.93

.75

.62

.53

.45

.39

.35

.31

.28

.25

1.11

.96

.84

.74

.65

.58

.53

.48

.44

.40

.37

1.11

.93

.78

.67

.58

.51

.45

.40

.36

.33

.30

1.11

.90

.73

.61

.52

.45

.39

.34

.31

.28

.25

1.06

.92

.80

.71

.63

.56

.51

.46

.42

.39

.36

1.06

.90

.76

.65

.56

.50

.44

.39

.36

.32

.30

1.06

.87

.72

.60

.51

.44

.39

.34

.31

.28

.25

1.02

.89

.77

.68

.61

.54

.49

.45

.41

.38

.35

1.02

.87

.74

.63

.55

.48

.43

.39

.35

.32

.29

1.02

.84

.70

.59

.50

.44

.38

.34

.30

.27

.25

1.00

.82

.68

.57

.48

.42

.36

.32

.28

.26

.23

AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k

2

3

4

5

6789

10

20

30

40

50LAMPS LUMINAIRE BUDGETARY DIAGRAM

456

H=7H=7

45

66

H=7H=7

CONDITIONS

FLUX 4901lm

FACTOR 0.70

Hdown 0.00m

Hwork 0.80m

Ework(AVE) 100lx

cc w fc

70 50 30

50 30 20

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

WEC AND CCEC

cc

w

fc

RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

.327

.303

.278

.255

.235

.217

.202

.188

.176

.165

.186

.166

.148

.133

.120

.109

.100

.092

.085

.079

.059

.051

.044

.039

.035

.031

.028

.026

.024

.022

.320

.296

.272

.250

.231

.213

.198

.185

.173

.163

.182

.163

.146

.131

.118

.108

.099

.091

.084

.079

.058

.050

.044

.039

.034

.031

.028

.026

.024

.022

.306

.285

.262

.241

.222

.206

.192

.179

.168

.158

.176

.158

.142

.128

.116

.106

.097

.090

.083

.077

.056

.049

.043

.038

.034

.031

.028

.026

.024

.022

.294

.274

.252

.232

.215

.199

.186

.174

.163

.154

.170

.154

.138

.125

.113

.104

.095

.088

.082

.076

.054

.048

.042

.038

.034

.030

.028

.025

.023

.022

.283

.264

.243

.224

.208

.193

.180

.169

.158

.149

.164

.149

.135

.122

.111

.102

.093

.087

.080

.075

.053

.047

.042

.037

.033

.030

.027

.025

.023

.022

cc

w

fc

RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio

80%

50% 30% 10%

20%

70%

50% 30% 10%

20%

50%

50% 30% 10%

20%

30%

50% 30% 10%

20%

10%

50% 30% 10%

20%

0

0

0

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

9.0

10.0

.190

.181

.174

.166

.158

.151

.143

.137

.130

.124

.118

.190

.156

.132

.114

.101

.091

.082

.076

.070

.065

.060

.190

.133

.097

.073

.057

.046

.039

.033

.028

.025

.022

.163

.155

.149

.142

.136

.129

.123

.117

.112

.107

.102

.163

.134

.114

.099

.087

.079

.071

.065

.060

.056

.053

.163

.114

.084

.063

.050

.040

.034

.029

.025

.022

.019

.111

.106

.102

.098

.093

.089

.085

.081

.077

.074

.071

.111

.092

.079

.069

.061

.055

.050

.046

.042

.040

.037

.111

.079

.058

.045

.035

.029

.024

.020

.018

.015

.014

.064

.061

.059

.056

.054

.052

.049

.047

.045

.043

.041

.064

.053

.046

.040

.036

.032

.029

.027

.025

.023

.022

.064

.046

.034

.026

.021

.017

.014

.012

.010

.009

.008

.020

.020

.019

.018

.017

.017

.016

.015

.015

.014

.013

.020

.017

.015

.013

.012

.011

.010

.009

.008

.008

.007

.020

.015

.011

.009

.007

.006

.005

.004

.003

.003

.003

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

Uncorrected UGR Table

ceiling/cavity

walls

working plane

Room dimensions Viewed crosswise Viewed endwise

0.7 0.7

0.5 0.5

0.2 0.2

0.7 0.7

0.3 0.3

0.2 0.2

0.5 0.5

0.5 0.5

0.2 0.2

0.5 0.5

0.3 0.3

0.2 0.2

0.3 0.3

0.3 0.3

0.2 0.2

x = 2H y = 2H

3H

4H

6H

8H

12H

4H 2H

3H

4H

6H

8H

12H

8H 4H

6H

8H

12H

12H 4H

6H

8H

10.5 10.5 12.0 12.0 10.7 10.7 12.2 12.2 12.4 12.4

12.1 12.1 13.6 13.6 12.4 12.4 13.8 13.8 14.0 14.1

12.8 12.9 14.2 14.2 13.2 13.2 14.5 14.5 14.7 14.7

13.4 13.5 14.7 14.7 13.7 13.8 15.0 15.0 15.3 15.3

13.6 13.7 14.9 14.9 14.0 14.0 15.2 15.2 15.5 15.5

13.8 13.9 15.0 15.1 14.1 14.2 15.3 15.4 15.6 15.7

11.1 11.1 12.5 12.5 11.4 11.4 12.7 12.7 13.0 13.0

13.0 13.0 14.2 14.2 13.3 13.3 14.5 14.5 14.8 14.8

13.8 13.8 14.9 14.9 14.2 14.2 15.2 15.3 15.6 15.6

14.5 14.6 15.5 15.6 14.9 15.0 15.9 15.9 16.2 16.3

14.8 14.9 15.7 15.8 15.2 15.3 16.1 16.2 16.5 16.6

15.1 15.1 15.9 16.0 15.5 15.6 16.3 16.4 16.7 16.8

14.1 14.2 15.1 15.1 14.5 14.6 15.4 15.4 15.8 15.8

15.0 15.1 15.8 15.9 15.5 15.5 16.2 16.3 16.6 16.7

15.4 15.5 16.1 16.2 15.9 16.0 16.5 16.6 17.0 17.1

15.8 15.9 16.4 16.5 16.3 16.4 16.8 16.9 17.3 17.4

14.2 14.2 15.0 15.0 14.6 14.6 15.4 15.4 15.8 15.8

15.1 15.2 15.8 15.9 15.6 15.6 16.2 16.3 16.7 16.7

15.6 15.6 16.2 16.2 16.1 16.1 16.6 16.7 17.1 17.2

Variations with the observer position at spacings:

S = 1.0H + 0.1 / - 0.2 + 0.1 / - 0.2

1.5H + 0.2 / - 0.3 + 0.2 / - 0.3

2.0H + 0.2 / - 0.3 + 0.1 / - 0.3

CIE Pub.117 Corrected 1000 lm Total Lamp Luminous Flux.(8log(F/F0) = 0.0)

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

UTILIZATION FACTORS TABLE

REFLECTANCE

Ceiling

Walls

Working plane

0.8

0.7

0.2

0.8

0.5

0.2

0.8

0.3

0.2

0.7

0.7

0.2

0.7

0.5

0.2

0.7

0.3

0.2

0.5

0.7

0.2

0.5

0.5

0.2

0.5

0.3

0.2

0

0

0

ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5

k = 0.60 57 45 38 56 44 38 55 44 37 31

0.80 66 55 47 65 54 47 64 53 46 39

1.00 75 63 56 74 63 56 71 64 55 48

1.25 82 71 64 80 70 63 78 69 62 55

1.50 87 77 69 85 76 69 82 74 68 60

2.00 94 85 78 92 84 77 88 82 76 68

2.50 98 90 83 96 88 83 92 86 81 72

3.00 101 94 88 99 93 87 95 90 85 76

4.00 105 99 95 103 98 93 99 94 91 81

5.00 108 103 99 106 101 97 101 97 94 85

ROOM INDEX UF(total) Direct

According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

ISOCANDELA DIAGRAM

-90-90

-80

-80

-70

-70

-60

-60

-50

-50

-40

-40

-30

-30

-20

-20

-10

-10

0

0

10

10

20

20

30

30

40

40

50

50

60

60

70

70

80

80

90

90

HORIZONTAL(DEG)

VERTICAL(DEG)

Imax:1625(H0.0,V0.0) (At:C=0.0,Gamma=0.0)

UNIT: cd

10% 162.520% 324.930% 487.440% 649.950% 812.360% 974.870% 113780% 130090% 1462

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

AAI Figure

1m3.281ft

315.76cm10.36ft

446.9,1625lx41.52,150.9fc

2m6.562ft

631.52cm20.72ft

111.7,406.2lx10.38,37.73fc

3m9.843ft

947.27cm31.08ft

49.66,180.5lx4.613,16.77fc

4m13.12ft

1263.03cm41.44ft

27.93,101.5lx2.595,9.434fc

5m16.4ft

1578.79cm51.8ft

17.88,64.99lx1.661,6.038fc

Height Eavg,Emax DiameterAngle:115.30deg

Flux out:3596 lm

Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

ISOLUX DIAGRAM

35.2' 10.72m

28.1' 8.58m

8.58m

28.1'

21.1' 6.43m

14.1' 4.29m

4.29m

14.1'

7.0' 2.14m

0.0' 0.00m

0.00m

0.0'

7.0' 2.14m

14.1' 4.29m

4.29m

14.1'

21.1' 6.43m

28.1' 8.58m

8.58m

28.1'

35.2' 10.72m

MOUNTING HEIGHT: 16'(5.0m)

3% 1.950lx 0.1811fc

5% 3.249lx 0.3019fc

10% 6.499lx 0.6038fc

30% 19.50lx 1.811fc

50% 32.49lx 3.019fc

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

Planar Illuminance Curve

Planar Illuminance Curve

-25 -20 -15 -10 -5 0 5 10 15 20 25

Distance(m)

0

6.5

13

19.5

26

32.5

39

45.5

52

58.5

65E(lx) MH = 5 m

C0/180

C90/270

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

LUMINOUS DISTRIBUTION INTENSITY DATA

(DEG)

C(DEG)

Table--1 UNIT: cd

0

0 1625

5 1618

10 1600

15 1567

20 1522

25 1465

30 1396

35 1314

40 1222

45 1121

50 1010

55 891

60 765

65 634

70 502

75 363

80 240

85 125

90 29.8

10

1624

1618

1599

1568

1524

1466

1396

1316

1224

1124

990

874

750

624

493

365

241

126

29.9

20

1624

1618

1598

1566

1521

1464

1394

1313

1222

1120

1009

890

765

634

502

363

240

125

29.9

30

1624

1618

1599

1567

1523

1466

1396

1315

1224

1110

990

872

750

624

493

365

242

127

30.1

40

1624

1618

1599

1566

1521

1464

1394

1312

1221

1119

1009

890

764

633

502

364

241

126

30.1

50

1623

1618

1599

1566

1521

1464

1394

1314

1222

1108

988

871

749

623

494

367

244

129

29.9

60

1623

1616

1597

1565

1520

1462

1392

1311

1219

1118

1007

888

763

634

502

366

243

128

29.6

70

1622

1617

1598

1566

1522

1463

1394

1313

1221

1108

988

871

749

625

496

369

246

130

29.5

80

1622

1616

1597

1565

1520

1462

1392

1311

1219

1117

1007

889

764

635

505

368

246

130

29.2

90

1621

1617

1598

1566

1522

1463

1395

1313

1222

1108

988

872

751

626

498

372

249

133

29.6

100

1620

1615

1597

1565

1520

1463

1394

1312

1220

1119

1009

891

767

638

508

370

248

132

30.2

110

1620

1615

1598

1566

1522

1465

1395

1316

1224

1111

990

874

753

629

500

373

250

133

30.7

120

1619

1614

1596

1566

1521

1464

1395

1314

1223

1122

1011

894

769

640

509

371

248

131

31.2

130

1619

1615

1598

1567

1523

1467

1398

1318

1227

1126

994

878

756

631

501

374

250

133

31.5

140

1618

1614

1597

1566

1522

1466

1398

1317

1226

1125

1015

897

772

642

510

372

248

131

31.5

150

1618

1615

1597

1567

1524

1468

1400

1320

1229

1129

996

880

758

632

502

374

249

133

31.3

160

1617

1614

1596

1566

1522

1466

1398

1319

1227

1127

1017

898

773

642

510

370

247

130

31.0

170

1617

1614

1596

1566

1523

1467

1400

1319

1229

1129

997

880

758

631

501

372

247

131

30.8

180

1625

1618

1598

1565

1519

1461

1391

1309

1218

1104

983

866

742

613

483

353

227

111

11.5

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu

SYOPTICS TEST CENTER

LUMINOUS DISTRIBUTION INTENSITY DATA

(DEG)

C(DEG)

Table--2 UNIT: cd

190

0 1617

5 1614

10 1596

15 1566

20 1523

25 1467

30 1400

35 1319

40 1229

45 1129

50 997

55 880

60 758

65 631

70 501

75 372

80 247

85 131

90 30.8

200

1617

1614

1596

1566

1522

1466

1398

1319

1227

1127

1017

898

773

642

510

370

247

130

31.0

210

1618

1615

1597

1567

1524

1468

1400

1320

1229

1129

996

880

758

632

502

374

249

133

31.3

220

1618

1614

1597

1566

1522

1466

1398

1317

1226

1125

1015

897

772

642

510

372

248

131

31.5

230

1619

1615

1598

1567

1523

1467

1398

1318

1227

1126

994

878

756

631

501

374

250

133

31.5

240

1619

1614

1596

1566

1521

1464

1395

1314

1223

1122

1011

894

769

640

509

371

248

131

31.2

250

1620

1615

1598

1566

1522

1465

1395

1316

1224

1111

990

874

753

629

500

373

250

133

30.7

260

1620

1615

1597

1565

1520

1463

1394

1312

1220

1119

1009

891

767

638

508

370

248

132

30.2

270

1621

1617

1598

1566

1522

1463

1395

1313

1222

1108

988

872

751

626

498

372

249

133

29.6

280

1622

1616

1597

1565

1520

1462

1392

1311

1219

1117

1007

889

764

635

505

368

246

130

29.2

290

1622

1617

1598

1566

1522

1463

1394

1313

1221

1108

988

871

749

625

496

369

246

130

29.5

300

1623

1616

1597

1565

1520

1462

1392

1311

1219

1118

1007

888

763

634

502

366

243

128

29.6

310

1623

1618

1599

1566

1521

1464

1394

1314

1222

1108

988

871

749

623

494

367

244

129

29.9

320

1624

1618

1599

1566

1521

1464

1394

1312

1221

1119

1009

890

764

633

502

364

241

126

30.1

330

1624

1618

1599

1567

1523

1466

1396

1315

1224

1110

990

872

750

624

493

365

242

127

30.1

340

1624

1618

1598

1566

1521

1464

1394

1313

1222

1120

1009

890

765

634

502

363

240

125

29.9

350

1624

1618

1599

1568

1524

1466

1396

1316

1224

1124

990

874

750

624

493

365

241

126

29.9

C Range: 0 - 360DEGC Interval: 10.0DEG

Range: 0 - 90DEG Interval: 1.0DEG

Test Speed: HIGH Test System:EVERFINE GO-2000B_V1 SYSTEM V1.0.254Temperature:25.2DEG Humidity:65.1%

Test Distance:8.040m [K=1.0000]Operators:Yuan FengTest Date:2014-11-05 Remarks: 220V/50Hz,settling time 30 minutes

Checker: Yuan Feng Assessor: Jianwei Liu