5
Heavy duty linear solenoid RM 060 Weight: Complete solenoid: appr. 1300 g Armature: appr. 250 g Standard: Voltage: 24 V DC Flying leads: 20 cm Insulation class: F (max. permissible temperature = 155 °C) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 12 mm. Force vs. Stroke diagram F = f (s) W = horizontal characteristic Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature stroke s = 0 corresponds to armature in fully home position 100 40 25 15 5 % Perm. duty Cycle (ED) 1) 25 60 98 150 381 W Nominal coil power P n 45 17 ms Actuation time (ED) 1) If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice) 0 5 10 12 15 s/mm F/N 10 20 50 1000 %ED 100 40 25 15 5 100 200 500 RM060 Series Linear Solenoid Thrust and/or Pull Type Document LNSRM6/15 Revision 002 Email: [email protected] Website: www.impulseautomation.co.uk Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Impulse Automation Limited United Kingdom Company Registration 665193

Transcript of 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or...

Page 1: 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or Pull Type Document LN S RM6 /15 Revision 00 2 ... 152 64 M6 M5 19 30 67 54 Ø 5,8 ...

Heavy duty linear solenoid RM 060

Weight:Complete solenoid: appr. 1300 gArmature: appr. 250 g

Standard:Voltage: 24 V DCFlying leads: 20 cm

Insulation class: F (max. permissibletemperature = 155 °C)

Service-free DU armature bearing for maximum durability.

Stroke of version with standard stroke limiter: 12 mm.

Force vs. Stroke diagram F = f (s)

W = horizontal characteristic

Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature

stroke s = 0 corresponds to armature in fully homeposition

100 40 25 15 5 % Perm. duty Cycle (ED)1)

25 60 98 150 381 W Nominal coil power Pn45 17 ms Actuation time (ED)

1) If solenoid is mounted directly onto a flat metalsurface the duty cycle can be extended (pleaseask for advice)

0 5 10 12 15s/mm

F/N

10

20

50

1000 %ED

100

4025

15

5

100

200

500

RM060 Series Linear Solenoid Thrust and/or Pull Type

Doc

umen

t LNSRM6/

15

Rev

isio

n 002

Email: [email protected]: www.impulseautomation.co.uk

Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.

Impulse Automation LimitedUnited Kingdom

Company Registration 665193

Page 2: 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or Pull Type Document LN S RM6 /15 Revision 00 2 ... 152 64 M6 M5 19 30 67 54 Ø 5,8 ...

2934

M6

M6

Ø35

18+1

375

415

7

~19

64

718

+1

Ø36

65

8

64152

M6

M5

3019 67

54

Ø5,

8

Ø60

Ø45

Ø35

M6

M6

Ø35

10

18+1

295

415

7

~36

81

18+1

Ø36

82

8

89162

Ø36

M6

M5

3019 67

54

Ø5,

8

Ø60

Ø45

Ø35

Direction of stroke

Direction of stroke

without stroke limiter

with stroke limiter

RM060 Series Linear Solenoid Thrust and/or Pull Type

Doc

umen

t LN

SR

M6/

25

Rev

isio

n 002

Email: [email protected]: www.impulseautomation.co.uk

Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.

Impulse Automation LimitedUnited Kingdom

Company Registration 665193

Dim

ensions given with

armature in fully hom

e positionD

imensions given w

ith arm

ature in fully home position

Page 3: 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or Pull Type Document LN S RM6 /15 Revision 00 2 ... 152 64 M6 M5 19 30 67 54 Ø 5,8 ...

Coil terminals

Examples of design types:–––––––>Direction of stroke

–OBOO– –OBLO– –OBOR– –ORRO– –OROR–

–HBOO– –HBLO– –HBOL– –HRRO– –HROR–

RM 060 – W – O R O R – N – 24 V DC 100 % ED Order specificationsRM Linear solenoid series

Design type ø mm060

W Horizontal frontal force vs. stroke output

Description2)

O Stroke limit withoutH with

R Plunger right hand side3)

B both sidesO Flange withoutR right hand side3)

L left hand side4)

O Gaiter withoutR right hand side3)

L left hand side4) 5)

B both sides5)

F Coil terminals Flying leads

N

(20 cm standard length)

plug-in socket connection6)

24 Operating voltage 24 V DC205 205 V DC (connected to

230 V AC with SI- bridgerectifier)

100 % ED Perm. duty cycle under air cooled conditions (LK)

2) See below3) Opposite to electrical connection4) Same side as electrical connection5) Available with stroke limit only6) For plug-in socket 6.3 DIN 46247 and plug

Z801 and Z811

N F

ca.1

2ca

.12

200

+15

RM060 Series Ordering Information

Doc

umen

t LNSRM6/35

R

evis

ion

002

Preferred types competitively priced available on a

quick delivery.

RM060W-OBOO-F-24VDC 100%ED

Email: [email protected]: www.impulseautomation.co.uk

Company Registration 665193Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.

Impulse Automation LimitedUnited Kingdom

Page 4: 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or Pull Type Document LN S RM6 /15 Revision 00 2 ... 152 64 M6 M5 19 30 67 54 Ø 5,8 ...

Plug-in socket Z801 Screw joint PG 9

for lead diameter 4.5 - 7 mm

Plug-in socket Z811

Screw joint PG 11 for lead diameter 6 - 9 mmPlug-in socket with built in

Si-bridge rectifier

Flange(Mounting screws are part of the

shipment)

Order specificationAK

ØL

CB

H

ØE

ØF

ØD

ØI

ØJ

ØG

Dimensions (mm) Order

AType B C D E F G H I J K L Type numberZ 840 RM 060 70,0 8,0 13,0 35,0 29,0 35,0 60,5 1,0 5,8 5,3 54,0 45,0 RM 060 Z 840

41,0≈10,0

(30,5)

Ø 1

9,0

5,5

34,2

Dimensions (mm)Order

number

RM060 Series Accessories

Doc

umen

t LN

SR

M6/

45

Rev

isio

n 002

Email: [email protected]: www.impulseautomation.co.uk

Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.

Impulse Automation LimitedUnited Kingdom

Company Registration 665193

Page 5: 60 Series Linear Solenoid Thrust and/or Pull Type · RM060 Series Linear Solenoid Thrust and/or Pull Type Document LN S RM6 /15 Revision 00 2 ... 152 64 M6 M5 19 30 67 54 Ø 5,8 ...

Stroke limiter(Mounting screws are part of theshipment)

Order specification

Fork

ØA

ØF

ØE

ØB

GH

D

C

KI

ØJ

A

C

F

G

E

ØD

B

Dimensions (mm) Order

A B C D E F G H I J K Type number

Z 845 RM 060 60,0 45,0 22,0 17,0 29,0 35,0 5,5 12,0 M5 5,3 10,0 RM 060 Z 845

Order-number

A B C D E F Connec-tion G

36.304 27 34 19 6 6 12 M6

Dimensions (mm)Order

number Type

RM060 Series Accessories

Doc

umen

t LN

SR

M6/

55

Rev

isio

n 002

Email: [email protected]: www.impulseautomation.co.uk

Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.

Impulse Automation LimitedUnited Kingdom

Company Registration 665193