+5W · 2019. 12. 19. · SOLAR.HUAWEI.COM/EU/ Efficiency [%] Efficiency Curve. Circuit Diagram....
Transcript of +5W · 2019. 12. 19. · SOLAR.HUAWEI.COM/EU/ Efficiency [%] Efficiency Curve. Circuit Diagram....
Tel:+86 25-86816810 Email:[email protected]:www.schutten-solar.com
© Anhui Schutten Solar Energy Co.,Ltd.STP6-XXX/60 Series_rev2018.8
80.7%
90.%
95.%97.5%100%
1 5 12 25
Additional value from Schutten Solar’s linear warranty
Excellent loading capability2400Pa wind loads, 5400Pa snow loads.
+5W
2400 Pa5400 Pa
High conversion efficiencyHigh module efficiency to guarantee power output.
Easy Installation and HandingFor various applications
Outstanding low irradiation performanceExcellent module efficiency even in the weak light conditions, such as morning or cloudy.
0 ~ +5W positive toleranceDetailed information in Electrical Specifications
Durability against extreme environmental High salt mist and ammonia resistance certified by TUV NORD
Years12
Guarantee on product material and workmanship
25Years
Linear power output warranty
FREEw
Anhui Schutten Solar Energy CO.,Ltd. known as
” Schutten Solar ”, is one of the world’s leading
solar panel manufacturers. Our Slogan is ” Blue Sky ·
Green Life ”. Deploying more than 2GW solar
STP6-XXX/60 Series260W/265W/270W/275W/280W
Poly-crystalline
panels worldwide.
Office(Nanjing) :Room 1812,Building A,Wanda Plaza,No.102 Middle Jiangdong Road,Nanjing,Jiangsu,China, 210019Factory(Chuzhou) :Weisan Rd, Quanjiao Economic Development Area Chuzhou City,Anhui Province,China, 239500Factory(Thailand) :41/9 Moo.8 T.Bowin, A.Sriracha, Chonburi, Thailand, 20230
Electrical CharacteristicsModule Type
Maximum Power (Pmax)
Maximum Power Voltage (Vmp)
Maximum Power Current (Imp)
Open-circuit Voltage (Voc)
Short-circuit Current (Isc)
Module Efficiency STC (%)
Power Tolerance 0~+5W
Mechanical Characteristics
Connector MC4 Compatible
Cell Type
No.of cells
Dimensions
Weight
Front Glass
Frame
Junction Box
Output Cables
Poly-crystalline 156.75×156.75mm (6 inch)
60 (6×10)
1640×992×35mm (64.56×39.05×1.37 inch)
18.0 kg (39.68 lbs.)
3.2mm, High Transmission, Low Iron, ARC Tempered Glass
Anodized Aluminium Alloy
IP67 Rated
4.0mm, Length: 900mm
STP6-280/60
Engineering Drawings
0~+5W 0~+5W 0~+5W
265Wp
31.40V
8.44A
38.60V
9.03A
16.19%
STP6-270/60
260Wp
31.10V
8.37A
38.10V
8.98A
15.88%
STP6-260/60 STP6-265/60
270Wp
31.70V
8.52
38.80V
9.09A
16.50%
0~+5W
STP6-275/60
275Wp
32.00V
8.61
39.10V
9.15A
16.80%
280Wp
32.30V
8.69A
39.40V
9.20A
17.11%
ⅢⅡⅠ
Warning:Read the installtion and user manual in its entirety beforehandling,installing,and operating schutten solar modules.
Schutten Partners:
I-V Curves
Thermal Characteristics
Temperature Coefficients of Pmax
Temperature Coefficients of Voc
Temperature Coefficients of Isc
Nominal Operating Cell Temperature (NOCT)
-0.40% / ℃
-0.31% / ℃
+0.06% / ℃
45 ± 2 ℃
Packaging ConfigurationContainer
Pieces Per Pallet
Pallets Per Container
Pieces Per Container
29 / 25 / 19
6 / 6 / 1
343 882
28 / 14
29 / 5
20’GP 40’HQ
Maximum RatingsOperating Temperature
Maximum System Voltage
Maximum Series Fuse Rating
-40℃~+85℃
1000VDC (IEC)
Maximum System Voltage 1500VDC (IEC)
15A
*All dimensions in mm(inch)
Pow
er (W
)
200W/m2
400W/m2
600W/m2
800W/m2
1000W/m2
Hailstone Impact Test 80Km/h for 25mm ice ball
STC : Irradiance 1000W/m2 AM=1.5Cell Temperature 25°C
1640
(64.
57)
992(39.06)A
A
35(1.38)
200-
250
900(
35.4
3)
Installing Holes
Grounding Holes
Cathode - + AnodeConnector
Ⅲ
Junction boxⅠ
A A
Ⅱ
2-Ø4
860(
33.8
6)13
60(5
3.54
)
952 (37.48)
45(1.77)
45(1
.77)
3(0.
12)
8
4.5(0.18)
14(0
.55)
9(0.35) 5.5(0.22)
30(1.18)
35(1
.38)
Current-Voltage & Power-Voltage Curves (270W)
5 10 200
0 10 20 30
35 500
2
4
6
8
10
8
6
4
2
0
10
0
50
150
200
250
300
25oC50oC75oC
Voltage (V)
Voltage (V)
Cur
rent
(A)
Cur
rent
(A)
Label
Serial Number
xxxxxxxx
SOLAR.HUAWEI.COM/EU/
Efficiency [%]
Efficiency Curve Circuit Diagram
Load [%] SUN2000-60KTL-M0
SUN2000-60KTL-M0Smart String Inverter
Type II surge arresters for DC & ACMax. efficiency 98.7%
Efficient12 strings intelligent monitoring
SafeFuse free design
ReliableSmart
90%91%92%93%94%95%96%97%98%99%
100%
0% 20% 40% 60% 80% 100%
520V
600V
800V
-
-
+
+
-
+
+
-
+
+
-
-
-
-
+
+
-
+
+
-
+
+
-
-
L1L2L3
PE
SPD
N
SPDDC/AC
InverterOutput
IsolationRelay
EMI Filter
EMI Filter
OutputFilter
MPPT1
MPPT2
MPPT3
MPPT4
MPPT5
MPPT6
SPD
DCSwitch 2
DCSwitch 1
CurrentSensor
SOLAR.HUAWEI.COM/EU/Version No.:02-(20190512)
Technical Specification
Technical Specification SUN2000-60KTL-M0
EfficiencyMax. efficiency 98.9% @480 V; 98.7% @380 V / 400 V
98.7% @480 V; 98.5% @380 V / 400 VEuropean efficiency
InputMax. Input Voltage 1 1,100 VMax. Current per MPPT 22 AMax. Short Circuit Current per MPPT 30 AStart Voltage 200 VMPPT Operating Voltage Range 2 200 V ~ 1,000 VRated Input Voltage 600 V @380 Vac / 400 Vac; 720 V @480 VacNumber of MPP trackers 6Max. number of inputs 12
OutputRated AC Active Power 60,000 WMax. AC Apparent Power 66,000 VAMax. AC Active Power (cosφ=1) 66,000 WRated Output Voltage 220 V / 380 V, 230 V / 400 V, default 3W + N + PE; 3W + PE optional in settings; 277 V / 480 V, 3W + PERated AC Grid Frequency 50 Hz / 60 HzRated Output Current 91.2 A @380 V, 86.7 A @400 V, 72.2 A @480 VMax. Output Current 100 A @380 V, 95.3 A @400 V, 79.4 A @480 VAdjustable Power Factor Range 0.8 leading... 0.8 laggingMax. Total Harmonic Distortion <3%
ProtectionInput-side Disconnection Device YesAnti-islanding Protection YesAC Overcurrent Protection YesDC Reverse-polarity Protection YesPV-array String Fault Monitoring YesDC Surge Arrester Type IIAC Surge Arrester Type IIDC Insulation Resistance Detection YesResidual Current Monitoring Unit Yes
CommunicationDisplay LED Indicators, Bluetooth/WLAN + APPRS485 YesUSB YesMonitoring BUS (MBUS) Yes
General DataDimensions (W x H x D) 1,075 x 555 x 300 mm (42.3 x 21.9 x 11.8 inch)Weight (with mounting plate) 74 kg (163.1 lb.)Operating Temperature Range -25°C ~ 60°C (-13°F ~ 140°F)Cooling Method Natural ConvectionMax. Operating Altitude 4,000 m (13,123 ft.)Relative Humidity 0 ~ 100%DC Connector Amphenol Helios H4AC Connector Waterproof PG Terminal + Terminal ClampProtection Degree IP65Topology TransformerlessNighttime Power Consumption < 2 W
Standard Compliance (more available upon request)Certificate EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683
Grid Connection Standards IEC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, VDE 4120, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699, P.O. 12.3, RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11
SUN2000-60KTL-M0
*1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter. *2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.
GAMA 300Three-phase electricity meter
for residenti al, commercial and industrial metering
• Measurement of active energy (bidirectional), reactive energy (in
4-quadrants) and maximum demand• Accuracy class 1.0 (B) or 0.5s (C)• Measurement in two channels (on phase
and neutral lines)• Single or Multi -tariff (up to 6 tariff s)• Internal real ti me clock• Load and billing profi les, instantaneous
values• Extended anti -tamper features• Event logbook (power outage, power
over-limit, reverse current fl ow, infl uence of magneti c fi eld, opening of
meter cover, opening of terminal cover, clock setti ng, parameter change, internal error, fi rmware update)
• Opti cal and electrical communicati on interfaces in accordance with IEC
62056-21 and/or DLMS/COSEM• Internal communication modules
(PLC modem, USB host, wireless or wired MBus, RS485, Ethernet), powering of external modem
• High-level security (encryption and authentication)
• Internal relay for user disconnecti on• Power quality monitoring (over-voltage,
under-voltage, over-current)• Measurement of Total Harmonic Distorti on (THD)• Registrati on of line and transformer
losses on the basis of I2h and U2h measurements
Technical Specifi cati onGAMA 300
• Connecti on type Three-phase 4-wire or 3-wire• Accuracy class:
- for acti ve energy- for acti ve energy, CT only- for reacti ve energy
class 1.0 (IEC 62053-21), class B (EN 50470-3)class 0.5s (IEC 62053-22), class C (EN 50470-3)class 2.0 (IEC 62053-23)
• Reference voltage, V:- 4 wire networks
- Multi -range- 3 wire networks
3x220/380; 3x230/400; 3x240/415; 3x57,7/100; 3x63,5/110;3x69,2/120; 3x120/208; 3x127/2203x57,7/100…230/4003x100; 3x110; 3x120; 3x220; 3x230
• Reference (maximum) current, A:- Direct connected- CT operated
5(60); 5(80); 5(100); 5(120); 10(60); 10(80); 10(100); 1(1,25); 1(6); 5(6,25); 5(10);
• Starti ng current 0,4% Ib (0,1% I
n if CT operated)
• Reference Frequency, Hz 50 or 60• Meter constant, imp/kWh, imp/kVArh 1…19999 (direct), 1…60000 (CT operated)• Power consumpti on per phase:
- In voltage circuit
- In current circuit
<1.0 VA (<0,5 W)<2.3 VA (<0.8 W) (with auxiliary electrical interface)<10 VA (<1.5 W) (with PLC modem)<10 VA (<2.2 W) (with PLC and wireless MBus modules)< 0,05 VA (< 0,5 VA if CT operated)
• Temperature range -40°C to +70°C
Rati ngs
Internal real-ti me clock• Accuracy < 0,5 s/24h (T = 23°C)• Backup power supply Li-ion batt ery and/or Super Cap• Li-ion batt ery Changeable or internal• Operati on durati on using only backup:
- Li-ion batt ery- Super Cap
> 12 yearsup to 7 days
Case & Dimensions• Case UV stabilized polycarbonate
• Insulati on Protecti ve class II
• Protecti on class IP53 (Opti onal IP54)
• Dimensions, mm 260 × 175 × 80
• Weight, kg < 1.5 kg
ELGAMA-ELEKTRONIKA Ltd.2 Visoriu str., LT-08300 Vilnius, Lithuania Phone: +370 5 2375000E-mail: marketi [email protected]
www.elgama.eu
AC 45...60 Hz power supply range of network voltages, V
90...260
Network frequency, Hz
50/60
Number of RS485 interfaces 1
Number of RS232 interfaces 1
Open circuit voltage of interface „20 mA current loop", V
12...15
Circuit current of interface „20 mA current loop", mA 18...22
PC-controller net baud rate via RS232 interface, 8N1 bytes 4800 baud
Maximum controller`s, connected to a current loop input (passive) interface, current loop`s voltage (must be connected through a surge protection of current loop), V
27
Number of meters, connected to 20 mA current loop interface 1...3
Number of meters connected to RS485 interface 1...32
Power consumption, W: - maximum in transmission mode - average in duty mode
< 2,5 < 1,2
Operation temperature -30...+50 ºC
Dimensions (without antene), mm 68 x 93 x 37
Relative humidity, % 5...95